Loading...
HomeMy WebLinkAbout08-8474 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 8474 f'IRE SPRINKI.ERSYSTEM PERMIT Permit Number: 8474 Address: 6606 GALL BLVD Permit Type: FIRE SPRINKLER SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE-SPRINKLER SYS Township: Range: Book: Proposed Use: COMMERCIAL Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 02-26-21-0010-05600-0020 Improv. Cost: 26,427.00 Date Issued: 11/07/2008 Name: SONNYS BAR-B-QUE Total Fees: 260.00 Address: 6606 GALL BLVD Amount Paid: 260.00 ZEPHYRHILLS, FL. 33542 Date Paid: 11/07/2008 Phone: Work Desc: INSTALL START 1-0 AFFF & FIRE SPRINKLER SYSTEM PHILLIPS FIRE SPRINKLERS INC FIRE SPRINKLER SYS 50.00 FIRE PLAN REVIEW FEES 100.00 FIRE INSPECTION FEES 110.00 p ; s*squii FIRE-PRESSURE TEST FIRE ACCEPTANCE Final Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDI G YOUR NOTICE OF COMMENCEMENT." a., ONT OR SIGNATURE I IC ER PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- Fire Marshal Office- 813-780-0041 813-780-0020 City of Zephyrhills Permit Application,f Fax-813-780-0021 Building Department Y Date Received A 2 7-v Phone Contact for Permitting -- OO 11111111111 rr,rrr r,,r,,r,,,,,,r,,,,,,,,,,,,,,,,,,,,,,,r,,, ,rrr,rr IIII IIIIIIIIIlIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 111111111 111111111 .,I I,, I, IIIIIIIIi,r,,,,,,,, Owner's Name I AJ C Owner Phone Number Owner's Address I L,�r✓' Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 6606 LOT# I SUBDIVISION PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT SIGN Q MOVE Q DEMOLISH INSTALL REPAIR PROPOSED USE Q SFR COMM Q OTHER TYPE OF CONSTRUCTION Q BLOCK FRAME El STEEL Q OTHER DESCRIPTION OF WORK �' ►L '-Q" r- r 2 BUILDING SIZE SQ FOOTAGE 7f C3 HEIGHT El BUILDING VALUATION OF TOTAL CONSTRUCTION 7 IIj ELECTRICAL $ AMP SERVICE PRO S ENERGY W.R.E.C. Elil PLUMBING $ 0 MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION 0 GAS Q ROOFING SPECIALTY Q OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES =NO BUILDER COMPANY SIGNATURE REGISTERED Y/ NI FEE CURRENT Y/N Address License# ELECTRICIAN COMPANY SIGNATURE REGISTERED I_Y/ NI FEE CURRENT Y/N Address License# PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURRENT Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/Y/ NI FEE CURRENT Y/N Address n cc License# I OTHER `'�C �` " COMPANY SIGNATURE REGISTERED NI FEE CURRENT / r— Address 133 i OGs„J C&7IV - License# 3O' / ()j¢ RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$5000) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. ' UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subwibd an w n (or affirm d befor by Q 0 Who is/are personally known to me or has/have produced Who is a ona l Icpcwn e as/have produced as identification. as identification. Notary Public /��QQ Notary Public Commission No. Commis An No. �U� Name of Notary typed,printed or stamped Name of Notary typ d, rinted or stamped CINDY ROSE DRYANT Nobly Pule-SW of Florkh 4ay Cw iM11un ErAw Jin 1e,2010 Ca�nlMlon too SOM OaiNd y I1 0aiM Nobly Awn. RS•,;•'•f r� .� '.y..;mot).11.t .3 .. • .c' . r,!� `�.' {•:-.i.'.it::i Vi1 Ce b$bt'VC' ,,. ^° ; g L F F. D E F A .. ,. 'i?.E N T c Dairy Road. '� a ll " 542 �?�.PJiI �J�?rj� ,;. �.13,E'i�E �. C"L. J��+ e"Si'e Oldaf x\e d .'r hill l$i ;us (u! )7 v-JO i Fax ( l3)780-3L44 FIRE SERVICE USER FEES Occupancy No.: Plan No.• Contractor: `�- ✓� � Business Name: Billing Address: Business Address: Business Phone No.: Billing Phone No.: � Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE 8 Site Plan N/C Annual N/C Sprinkler 1st Alarm N/C Multi-Family/C:ommercial .06 sf 1st Re-inspection N/C Standpipes 2nd Alarm N/C (Minimum Charge$25.00 2nd Re-inspection $100 Fire Pump $50 3rd Alarm WC fl Plan Revisions DBL 3rd Re-inspection $250 Hoods $50 4th Alarm $100 4th Re-Inspection $500 Fire Alarm $50 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until LP Gas $50 6th Alarm $200 0-25 Heads violations corrected) Natural Gas $50 NON COMPUANCE $150 26 plus Heads $1 SPRINKLER SYSTEMS Fuel Tanks- per tank $50 STANDPIPE SYS Hydro Undergrounds Sparklers $100 0 Per Riser $50 4 Hydrostatic Test $65 Fire Works $500 FIRE PUMP Acceptance Test system Camp Fire $25 Per Pump $100 tJ Hydrant Flow 5 Controlled Bum $100 FIRE ALARM SYSTEM Hood/Duct $50 0-25 Devices $50 FIRE ALARM SYSTEM Place of Assembly $50 Annual 26 plus Devices $100 System Acceptance $50 Fire Protection $25 SUPPRESSION SYSTEMS Recall Acceptance $50 Flammable Application $50 Annual Wet $50 OTHER Waste Tire Storage $50 Annual Dry $50 Fire Wail/smoke wall $15• perwali Generator<KW $100 CO2 $50 LP Gas $25 pertank Generator>30 KW 150 Other $50 Natural Gas $25 per system Bio-Hazard Waste $100 Annual KITCHEN EXHAUST Fumigation Tenting $50 Hood/Ducts $50 Tent I0x10'or greater $15 per tent Torch Pot/Applied $50 OTHER Fire Pump $45 Haz.Materials $100 Annual IP Installation per tank $50 Fire Suppression $30 Fuel Tank Installation $50 System Acceptance (Per Tank) $50 Exhaust Hood/Duct $30 flNatural Gas Installation $50 Re-Inspection DBL (Per System) (other than annual) Spray Booth $50 Inspection scheduled DBL and cancelled less than 24 hours Construction Insp. N/C Emergency Vehicle Ac $50 — ------FALSE ALARM PLANS TOTAL % - INSPECTION TOTAL PERMIT TOTAL TOTAL !!!!!! GRAND TOTAL r c Comments: Date: *F lnsW,ctor. _ Zephyrhills Fire Rescue 6907 Dairy Road,Zephyrhills,FL 33542 Fire Marshal Bus (813)780-0041 Kerry Barnett Fax(813)780-0044 E-mail: kbarnett@fire.zephyrhills.fl.us Plan Review#: 08-135 Project: Sonny's Number of Pages: 1 plus spec package and calcs Date: October 28, 2008 I have reviewed the plans for the sprinkler system located at 6606 Gall Blvd therefore allowing this project to move forward. Paying for the permit acknowledges the contractor agrees to the items below. Should anyone have any questions,please do not hesitate to contact the Fire Marshal's office. 1. System shall be compliant with the latest edition of NFPA 13. 2. Install sprinkler cabinet inside by riser. 3. Ensure that there are no unprotected ceiling pockets as allowed by 8.6.7 and 8.8.7(NFPA 13)exceeding 32 sq ft to allow for the reduction in accordance with 11.2.3.2.3.1. This is because the building is constructed of wood which is not non combustible or limited combustible product. Inspections Required: 1. Pressure Test 2. Acceptance Test KE TT,FIRE MARSHAL ***Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes.This review is not intended to be a final approval of the submitted plans.It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances.In the event that further examination or site inspection reveals areas of non-compliance,it shall be the contractor's sole responsibility,at their sole expense to bring those areas in compliance.The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. Hydraulic Calculations for; Sonny's Real Pit Bar-B-Que 6606 Gall Blvd. Zephyrhills, Florida 33542 SIJBMITI'ED PLAN BY ZEPHYR S)HAVE BEEN REVIEWED at ZEPHYR S R Dau: r: MAI HAL'S OFFICE Reviewe Phillips Fire Sprinklers, Inc. "The Service You Deserve" cv cn c� i cn e.J cv () fl Phillips Fire Sprinklers, Inc. 9331 East Fowler Avenue J -- Thonotasassa, Florida 33592 813-663-0011 nor , w Job Name : SONNY'S BBQ Building RESTAURANT Location : 6606 GALL BLVD. ZEPHYRHILLS, FL 33542 System : #1 Contract : 2C08-0009 Data File : PERMIT.WX1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Phillips Fire Sprinklers, Inc. Page 1 SONNY'S BBQ Date 101708 Hydraulic Design Information Sheet Name - SONNY' REAL PIT BAR-B-QUE Date - 10-23-08 Location - 6606 GALL BLVD. ZEPHYRHILLS, FL 33542 Building - RESTAURANT System No. - #1 Contractor - PHILLIPS FIRE SPRINKLERS, INC. Contract No. - 2C08-0009 Calculated By - LORI FINLEY Drawing No. - FP-1 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 10'0" Occupancy - KITCHEN S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 (x) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C (x) Figure 11.2.3.2.3.1 Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1, 100sgft System Type Sprinkler/Nozzle Density - .20 ( ) Wet Make TYCO D Area Per Sprinkler - 130sqft ( ) Dry Model TY-FRB E Elevation at Highest Outlet - 12'-5" ( ) Deluge Size 1/2" S Hose Allowance - Inside - 100gpm ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - Ogpm ( ) Other Temp.Rat.200deg G Hose Allowance - Outside - 150gpm N Note 30% REDUCTION IN AREA OF OPERATION PER THE ABOVE MENTIONED FIGURE Calculation Flow Required - 546.019 Press Required - 39.153 12.583 SAFETY Summary C-Factor Used: 120 Overhead 140 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 10-14-08 Cap. - T Time of Test - 4:00 PM Rated Cap.- Elev.- E Static Press - 55psi @ Press - R Residual Press - 45psi Elev. - Well Flow - 1, 000gpm Proof Flow S Elevation - 0 U _ P Location - 66066 GALL BLVD. ZEPHYRHILLS ZEPHYRHILLS FIRE DEPARTMENT P L Source of Information - Y C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M ( ) Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 N U 00 O M N2 � • NM O4U) N N ao 2 'O U) (0 E .22 -oN CLLd 'CO C U m N N N`p N rn O 0 N � w v�QO mg wcoU) cn� -6•-NN OO cv) (p 0CCOMMO(l) E u) o co O M O O Cl) O Z) - -- - - O Z E c0 C c_ 1 O Cl-- - - - - a� O U C U t Co O< 2 CDD Z O O Co J C) LL O N- - - - - - - - - . - ± - - O 7 O E O U O O O O U)LO O ►nv— N L N O - - - O C Vl N O M d LL N c0 m a > > O U Y o.Y 2 -- - O Q_ OO LO U) 00 N , O U) 2 �UUUiito Z O m - Z U a Q w w 0 ) w w a0 o- N O(O. (D co O 0).- 1- No OLOOOLO O M Co O 0)0)v co N d0 (D ovG000v (O(O.-ID N- O N N N(.O((OON O O)N O O N .-NOU()N ti Co ) O O co M O O - (�- D (O M N(-)C)N Z (O 0.-N Nr E (0 N O N O O c C NN.- O)r (+) O 00.,—o0 U v N N h(D.-- •--(D U 3 � o EL (N O LC) ' IC) C >+ O Z > O) .O O r O st O)0Dvm E N (` U) .c C) O \ J 7 2 O M N-CD M-O C X C N I.. N N ON (C)LC)N U) � E Q N O N U C o a C)NLL) V N � N Nc U) C Cl) (� U N O ON v(vNLL C LL. :Da.. a) cci Co V >> Y 3 t w tW rnHO Y �� 3 00 aQ U 00�U "u'o U CU O O Y to � � CU E Q Z J 5 (/) w = - Z rnm u) E rn3 w LL a O LL < CO W v7 F-N N ) O J LL d Pressure / Flow Summary - STANDARD Phillips Fire Sprinklers, Inc. Page 4 SONNY'S BBQ Date 101708 Node Elevation K'Fact Pt Pn Flow Density Area Press No. _______ Actual _ Actual_ Req. D001 13.75 5.6 21.56 na 26.0 0.2 130 7.0 D002 13.75 5.6 21.56 na 26.0 0.2 130 7.0 D003 13.75 5.6 21.56 na 26.0 0.2 130 7.0 D1 12.5 5.6 10.94 na 18.52 0.2 68 7.0 D2 12.5 5.6 10.83 na 18.43 0.2 35 7.0 D3 12.5 5.6 11.29 na 18.81 0.2 60 7.0 D4 12.5 5.6 12.0 na 19.4 0.2 97 7.0 D5 12.5 5.6 12.24 na 19.59 0.2 87 7.0 D6 12.5 5.6 12.79 na 20.03 0.2 80 7.0 D7 12.5 5.6 11.35 na 18.86 0.2 34 7.0 D8 12.5 5.6 12.18 na 19.54 0.2 68.75 7.0 D9 12.5 5.6 13.17 na 20.32 0.2 64 7.0 D10 12.5 5.6 13.98 na 20.94 0.2 64 7.0 D11 12.5 5.6 12.2 na 19.56 0.2 64 7.0 D12 12.5 5.6 12.56 na 19.84 0.2 64 7.0 D13 12.5 5.6 14.17 na 21.08 0.2 80 7.0 D14 12.5 5.6 14.48 na 21.31 0.2 64 7.0 D15 12.5 5.6 12.49 na 19.79 0.2 64 7.0 1 12.5 11.49 na 2 12.5 11.38 na 3 12.5 11.86 na 4 12.5 12.65 na 5 12.5 12.9 na 6 12.5 13.49 na 7 12.5 11.97 na 8 12.5 12.84 na 9 12.5 13.83 na 10 12.5 14.68 na 11 12.5 12.81 na 12 12.5 13.19 na 13 12.5 14.87 na 14 12.5 15.2 na 15 12.5 16.48 na 101 12.0 12.37 na 102 12.0 13.14 na 103 12.0 13.18 na 104 12.0 13.86 na 105 12.0 14.23 na 106 12.0 14.78 na 201 12.0 14.1 na 202 12.0 15.41 na 203 12.0 16.31 na 301 12.0 13.7 na 302 12.0 14.48 na 303 12.0 16.32 na 304 12.0 17.51 na 401 12.0 16.11 na 402 12.0 17.02 na 403 12.0 17.4 na 404 12.0 17.79 na 501 12.0 18.29 na 502 12.0 18.32 na 503 12.0 18.4 na 504 12.0 18.52 na 505T 13.75 18.24 na 505B 12.0 19.32 na 506 12.0 19.64 na 507 12.0 20.44 na 508 12.0 20.89 na TOR 12.0 21.64 na BOR 1.0 27.78 na 100.0 UG1 0.0 30.75 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard Phillips Fire Sprinklers, Inc. Page 5 SONNY'S BBQ Date 101708 Node Elevation K'Fact Pt Pn Flow Density Area Press No. Actual Actual BFP 2.0 35.25 na UG2 0.0 39.12 na TEST 0.0 39.15 na 150.0 The maximum velocity is 10.11 and it occurs in the pipe between nodes 106 and 501 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Phillips Fire Sprinklers, Inc. Page 6 SONNY'S BBQ Date 101708 Hyd. Qa Dia Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn D001 26.00 1.049 1 E 2.0 1.000 21.556 K Factor= 5.60 to 120 0.0 2.000 0.0 EQ01 26.0 0.2113 0.0 3.000 0.634 Vel = 9.65 0.0 26.00 22.190 K Factor= 5.52 D002 26.00 1.049 1 E 2.0 1.000 21.556 K Factor= 5.60 to 120 0.0 2.000 0.0 EQ02 26.0 0.2113 0.0 3.000 0.634 Vel= 9.65 0.0 26.00 22.190 K Factor= 5.52 D003 26.00 1.049 1 E 2.0 1.000 21.556 K Factor= 5.60 to 120 0.0 2.000 0.0 EQ03 26.0 0.2113 0.0 3.000 0.634 Vel = 9.65 0.0 26.00 22.190 K Factor= 5.52 D1 18.52 1.104 1E 2.565 3.750 10.937 K Factor= 5.60 to 120 0.0 2.565 0.0 1 18.52 0.0880 0.0 6.315 0.556 Vel = 6.21 0.0 18.52 11.493 K Factor= 5.46 D2 18.43 1.104 1E 2.565 3.750 10.829 K Factor= 5.60 to 120 0.0 2.565 0.0 2 18.43 0.0871 0.0 6.315 0.550 Vel= 6.18 0.0 18.43 11.379 K Factor= 5.46 D3 18.81 1.104 1E 2.565 3.750 11.285 K Factor= 5.60 to 120 0.0 2.565 0.0 3 18.81 0.0907 0.0 6.315 0.573 Vel = 6.30 0.0 18.81 11.858 __ K Factor= 5.46 D4 19.40 1.104 1E 2.565 4.250 12.001 K Factor= 5.60 to 120 0.0 2.565 0.0 4 19.4 0.0960 0.0 6.815 0.654 Vel = 6.50 0.0 19.40 12.655 K Factor= 5.45 D5 19.59 1.104 1 E 2.565 4.250 12.236 K Factor= 5.60 to 120 0.0 2.565 0.0 5 19.59 0.0977 0.0 6.815 0.666 Vel= 6.57 0.0 19.59 12.902 K Factor= 5.45 D6 20.03 1.104 1E 2.565 4.250 12.794 K Factor= 5.60 to 120 0.0 2.565 0.0 6 20.03 0.1018 0.0 6.815 0.694 Vel = 6.71 0.0 20.03 13.488 K Factor= 5.45 D7 18.86 1.104 1E 2.565 4.250 11.346 K Factor= 5.60 to 120 0.0 2.565 0.0 7 18.86 0.0910 0.0 6.815 0.620 Vel = 6.32 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Phillips Fire Sprinklers, Inc. Page 7 SONNY'S BBQ Date 101708 Hyd. Qa Dia' Fitting P)pe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 18.86 11.966 K Factor= 5.45 D8 19.54 1.104 1E 2.565 4.250 12.176 K Factor= 5.60 to 120 0.0 2.565 0.0 8 19.54 0.0973 0.0 6.815 0.663 Vel = 6.55 0.0 19.54 12.839 K Factor= 5.45 D9 20.32 1.104 1E 2.565 3.750 13.167 K Factor= 5.60 to 120 0.0 2.565 0.0 9 20.32 0.1045 0.0 6.315 0.660 Vel = 6.81 0.0 20.32 13.827 K Factor= 5.46 D10 20.94 1.104 1E 2.565 3.750 13.980 K Factor= 5.60 to 120 0.0 2.565 0.0 10 20.94 0.1104 0.0 6.315 0.697 Vel = 7.02 0.0 20.94 14.677 K Factor= 5.47 D11 19.56 1.104 1E 2.565 3.750 12.196 K Factor= 5.60 to 120 0.0 2.565 0.0 11 19.56 0.0974 0.0 6.315 0.615 Vel = 6.56 0.0 19.56 12.811 K Factor= 5.46 D12 19.84 1.104 1E 2.565 3.750 12.555 K Factor= 5.60 to 120 0.0 2.565 0.0 12 19.84 0.1001 0.0 6.315 0.632 Vel = 6.65 0.0 19.84 13.187 K Factor= 5.46 D13 21.08 1.104 1E 2.565 3.750 14.168 K Factor= 5.60 to 120 0.0 2.565 0.0 13 21.08 0.1118 0.0 6.315 0.706 Vel = 7.07 0.0 21.08 14.874 K Factor= 5.47 D14 21.31 1.104 1E 2.565 3.750 14.476 K Factor= 5.60 to 120 0.0 2.565 0.0 14 21.31 0.1140 0.0 6.315 0.720 Vel= 7.14 0.0 21.31 15.196 K Factor= 5.47 D15 19.79 1.104 1 E 2.565 37.500 12.492 K Factor= 5.60 to 120 0.0 2.565 0.0 15 19.79 0.0995 0.0 40.065 3.987 Vel = 6.63 0.0 19.79 16.479 K Factor= 4.88 1 18.52 1.104 2E 5.13 2.340 11.493 to 120 0.0 5.130 0.217 101 18.52 0.0878 0.0 7.470 0.656 Vel= 6.21 0.0 18.52 12.366 K Factor= 5.27 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Phillips Fire Sprinklers, Inc. Page 8 SONNY'S BBQ Date 101708 Hyd. Qa Dial Fitting Pipe Pt Pt ******* ****** Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 2 18.43 1.104 2E 5.13 6.125 11.379 to 120 1 T 6.413 11.543 0.217 102 18.43 0.0872 0.0 17.668 1.541 Vel = 6.18 0.0 18.43 13.137 K Factor= 5.08 3 18.81 1.104 1E 2.565 3.208 11.858 to 120 1 T 6.413 8.978 0.217 103 18.81 0.0905 0.0 12.186 1.103 Vet= 6.30 0.0 18.81 13.178 K Factor= 5.18 4 19.40 1.104 1E 2.565 1.375 12.655 to 120 1 T 6.413 8.978 0.217 104 19.4 0.0958 0.0 10.353 0.992 Vet= 6.50 0.0 19.40 13.864 K Factor= 5.21 5 19.59 1.104 1E 2.565 2.375 12.902 to 120 1 T 6.413 8.978 0.217 105 19.59 0.0976 0.0 11.353 1.108 Vel= 6.57 0.0 19.59 14.227 K Factor= 5.19 --- - --- ---------- 6 20.03 1.104 1E 2.565 1.625 13.488 to 120 1 T 6.413 8.978 0.217 106 20.03 0.1017 0.0 10.603 1.078 Vel= 6.71 --------------- 0.0 20.03 14.783 K Factor= 5.21 --- 7 18.86 1.104 3E 7.695 13.375 11.966 to 120 0.0 7.695 0.217 201 18.86 0.0910 0.0 21.070 1.918 Vet = 6.32 0.0 18.86 14.101 K Factor= 5.02 8 19.54 1.104 2E 5.13 5.625 12.839 to 120 0.0 5.130 0.217 201 19.54 0.0972 0.0 10.755 1.045 Vel= 6.55 0.0 19.54 14.101 K Factor= 5.20 9 20.32 1.104 1E 2.565 4.125 13.827 to 120 1 T 6.413 8.978 0.217 202 20.32 0.1045 0.0 13.103 1.369 Vet = 6.81 0.0 20.32 15.413 K Factor= 5.18 10 20.94 1.104 1 E 2.565 3.875 14.677 to 120 1 T 6.413 8.978 0.217 203 20.94 0.1104 0.0 12.853 1.419 Vel = 7.02 0.0 20.94 16.313 K Factor= 5.18 11 19.56 1.104 2E 5.13 1.750 12.811 to 120 0.0 5.130 0.217 301 19.56 0.0972 0.0 6.880 0.669 Vet= 6.56 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Phillips Fire Sprinklers, Inc. Page 9 SONNY'S BBQ Date 101708 Hyd. Qa Did. Fitting Pipe Pt Pt Ref. 'c' or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 19.56 13.697 K Factor= 5.29 12 19.84 1.104 1 E 2.565 1.750 13.187 to 120 1 T 6.413 8.978 0.217 302 19.84 0.0999 0.0 10.728 1.072 Vel= 6.65 0.0 19.84 14.476 K Factor= 5.21 13 21.08 1.104 1E 2.565 2.000 14.874 to 120 1 T 6.413 8.978 0.217 303 21.08 0.1118 0.0 10.978 1.227 Vel= 7.07 0.0 21.08 16.318 K Factor= 5.22 14 21.31 1.104 2E 5.13 1.000 15.196 to 120 0.0 5.130 0.217 401 21.31 0.1140 0.0 6.130 0.699 Vel= 7.14 0.0 21.31 16.112 K Factor= 5.31 15 19.79 1.452 1E 3.843 1.000 16.479 to 120 1 T 7.686 11.529 0.217 402 19.79 0.0262 0.0 12.529 0.328 Vel= 3.830.0 19.79 17.024 K Factor= 4.80 101 18.52 1.104 0.0 8.750 12.366 to 120 0.0 0.0 0.0 102 18.52 0.0881 0.0 8.750 0.771 Vet = 6.21 102 18.43 1.452 0.0 0.500 13.137 to 120 0.0 0.0 0.0 103 36.95 0.0820 0.0 0.500 0.041 Vel= 7.16 103 18.81 1.687 0.0 8.000 13.178 to 120 0.0 0.0 0.0 104 55.76 0.0858 0.0 8.000 0.686 Vel = 8.00 104 19.40 2.154 0.0 8.000 13.864 to 120 0.0 0.0 0.0 105 75.16 0.0454 0.0 8.000 0.363 Vel = 6.62 105 19.59 2.154 0.0 8.000 14.227 to 120 0.0 0.0 0.0 106 94.75 0.0695 0.0 8.000 0.556 Vel = 8.34 106 20.03 2.154 1 T 12.224 23.125 14.783 to 120 0.0 12.224 0.0 501 114.78 0.0992 0.0 35.349 3.507 Vet = 10.11 0.0 114.78 18.290 K Factor= 26.84 201 38.40 1.452 IT 7.686 7.000 14.101 to 120 0.0 7.686 0.0 202 38.4 0.0893 0.0 14.686 1.312 - Vet = 7.44 202 20.32 1.687 0.0 9.541 15.413 to 120 0.0 0.0 0.0 203 58.72 0.0943 0.0 9.541 0.900 Vet = 8.43 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Page 10 Phillips Fire Sprinklers, Inc. Date 101708 SONNY'S BBQ Hyd. Qa Dia. Fitting Pipe Pt Pt *..***• Notes Ref. "c' or Ftng's Pe Pv Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 203 20.94 2.154 IT 12.224 27.583 16.313 to 120 0.0 12.224 0.0 502 79.66 0.0505 0.0 39.807 2.009 Vel = 7.01 0.0 18 322 K Factor= 18.61 79.66 301 19.56 1.104 0.0 8.000 13.697 to 120 0.0 0.0 0.0 302 19.56 0.0974 0.0 8.000 0.779 Vel = 6.56 302 19.84 1.452 0.0 19.666 14.476 to 120 0.0 0.0 0.0 303 39.4 0.0937 0.0 19.666 1.842 Vel = 7.63 303 21.08 1.687 0.0 12.000 16.318 to 120 0.0 0.0 0.0 304 60.48 0.0997 0.0 12.000 1.196 Vel = 8.68 304 0.0 2.154 1 T 12.224 17.125 17.514 to 120 0.0 12.224 0.0 503 60.48 0.0303 0.0 29.349 0.890 Vel = 5.32 0.0 18.404 K Factor= 14.10 60.48 401 21.31 1.104 0.0 8.000 16.112 to 120 0.0 0.0 0.0 402 21.31 0.1140 0.0 8.000 0.912 Vel= 7.14 402 19.79 1.452 0.0 3.666 17.024 to 120 0.0 0.0 0.0 403 41.1 0.1012 0.0 3.666 0.371 Vel = 7.96 403 0.0 1.687 0.0 8.000 17.395 to 120 0.0 0.0 0.0 404 41.1 _0.0488 0.0 8.000 0.390 Vel= 5.90 404 0.0 2.154 1 T 12.224 37.125 17.785 to 120 0.0 12.224 0.0 = -_--__ 504 41.1 0.0149 -__ _ _0.0 49.349 _ 0.733 Vel 3.62 0.0 K Factor= 9.55 41.10 18.518 501 114.78 4.26 0.0 9.041 18.290 to 120 0.0 0.0 0.0 502 114.78 0.0035 0.0 9.041 0.032 Vel = 2.58 502 79.66 4.26 0.0 8.583 18.322 to 120 0.0 0.0 0.0 503 194.44 0.0096 0.0 8.583 0.082 Vel = 4.38 503 60.48 4.26 0.0 7.250 18.404 to 120 0.0 0.0 0.0 504 254.92 0.0157 0.0 7.250 0.114 Vel = 5.74 504 41.10 4.26 1E 13.167 10.083 18.518 to 120 0.0 13.167 -0.758 505T 296.02 0.0206_--_ _0.0 23.250 0.480 Vel = 6.66 —_ 505T 0.0 4.26 1E 13.167 2.500 18.240 to 120 0.0 13.167 0.758 505B 296.02 0.0207 0.0 15.667 0.324 Vel = 6.66 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Phillips Fire Sprinklers, Inc. Page 11 SONNY'S BBQ Date 101708 Hyd. Qa Dia. Fitting Pipe Pt Pt ******* ****** Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 505B 0.0 4.26 1E 13.167 2.000 19.322 to 120 0.0 13.167 0.0 506 296.02 0.0207 0.0 15.167 0.314 Vet= 6.66 506 0.0 4.26 1E 13.167 25.916 19.636 to 120 0.0 13.167 0.0 507 296.02 0.0206 0.0 39.083 0.807 Vet = 6.66 507 0.0 4.26 1E 13.167 8.375 20.443 to 120 0.0 13.167 0.0 508 296.02 0.0207 0.0 21.542 0.446 Vel= 6.66 508 0.0 4.26 1E 13.167 23.416 20.889 to 120 0.0 13.167 0.0 TOR 296.02 0.0207 0.0 36.583 0.756 Vel = 6.66 TOR 0.0 4.26 1 B 15.8 8.500 21.645 to 120 IS 28.968 57.935 4.764 BOR 296.02 0.0207 1Z 13.167 66.435 1.373 Vel = 6.66 BOR 100.00 4.1 2E 29.067 50.000 27.782 Qa= 100 to 140 0.0 29.067 0.433 UG1 396.02 0.0321 0.0 79.067 2.537 Vet= 9.62 UG1 0.0 4.1 2E 29.067 15.000 30.752 to 140 1 Zaf 0.0 29.067 3.080 *Fixed loss= 3.947 BFP 396.02 0.0321 0.0 44.067 1.415 Vel= 9.62 BFP 0.0 4.1 1E 14.534 50.000 35.247 to 140 1 T 29.067 43.601 0.866 UG2 396.02 0.0321 0.0 93.601 3.003 Vel= 9.62 UG2 0.0 10.28 0.0 100.000 39.116 to 140 0.0 0.0 0.0 TEST 396.02 0.0004 0.0 100.000 0.037 Vel = 1.53 150.00 Qa = 150.00 546.02 39.153 K Factor= 87.26 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087