Loading...
HomeMy WebLinkAbout07-7035 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 7035 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL Permit#:7035 Issued: 9/25/2007 Address: 5541 13TH ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: SINGLE FAMILY RESIDENTIAL Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 227,480.00 Total Fees: 12,038.39 Subdivision: CITY OF ZEPHYRHILLS Amount Paid: 4,804.55 Date Paid: 9/25/2007 Parcel Number: 11-26-21-0010-11600-0090 Name: PERILLO &ASSOCIATES LLC Name: MULLIGAN, JOHN Addr: 27800 LINCOLN PLACE Address: 5541 13TH ST WESLEY CHAPEL, FL 33544-5416 ZEPHYRHILLS, FL. 33542 Phone: (813)782-8944 Lic: Phone: (813)778-1215 Work Desc: SINGLE FAMILY RESIDENCE (2420 SQ FT) BUILDING FEE 941.28 ELECTRICAL FEE 194.40 PLUMBING FEE 129.60 MECHANICAL FEE 90.72 RADON 24.20 SEWER CONNECTION RESIDENT 2,010.00 WATER CONNECTION RESIDENT 641.00 WATER METER RES 3/4" 220.00 POLICE IMPACT FEE 254.00' FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 CHOOL IMPACT FEE/100% CHOOL IMPACT FEE 1% p�S ' TRAFFIC IMPACT FEE 99% 1,572.12 TRAFFIC IMPACT FEE 1% 15.88 {'5- /, 472W W y Xe,7' '? /qa. - -� O7 FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80(2)(c) when extra inspection trips are necessary due to any one of the following reasons: a)wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d)work not ready for inspection when called e) permit not posted on job site f) plans not at job site g)work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." ,CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER P . 01/01 TRANSACTION REPORT FEB/ 18/2008/MON 03 : 59 PM FAX ( TX) # DATE START T. RECEIVER COM.TIME PAGE TYPE/NOTE FILE 01 FEB/18 03: 58PM 93156461 0:00: 54 2 OK ECM 8270• City of Zephyrhills: f•:, ;::::,::, Building Department. 1"••Y:yrLV..,lf+1a.+ ��:ll`"a • ::,:[:...............:�M".�i:J� Phone: (813)-780-0020 Fax: . (813)-780-0021 `w TO: Peggy FROM: Jackie . • FAX#:813-315-6461 FAX#: DATE: 2-17-09 #OF PAGES including cover sheet:2 • i MESSAGE:• Attached is information about the impact fee credit for existing structure. Jackie • . Support Specialist ------------ ----------------------------- -------- ------_---. --��• City of Zephyrhills: Building Department Phone: (813)-780-0020 Fax: (813)-780-0021 TO: Peggy FROM: Jackie € E FAX#:813-315-6461 FAX#: € € DATE: 2-17-09 # OF PAGES including cover sheet: 2 f € € I E € € q MESSAGE: E € Attached is information about the impact fee credit for existing structure . E € E € f E r € Jackie Support Specialist 9 ; 9 ; I E E € € q € € E E E € € E I p S I 4 € I € I E E € f € I I E € E E € I E I f € f f f I CITY OF ZEPHYRHILLS "City of Pure Water" Building Department 5335 Eighth Street•Zephyrhills, Florida 33542-4312 (813) 780-0020 • Fax (813) 780-0021 W. A. "Bill" BurgessFebruary 17, 2009 Director of Building Licensing&Zoning Ir. John Mulligan 541 13th Street ephyrhills, Fl. 33542 ear Sir: You turned in tax records showing that an existing home was located on parcel ID # 11-26-21- 010-11600-0090. Bill Burgess our building official has reviewed the tax record and he has etermined that the fees listed below would not have to be paid because of the prior existing esidence but you are to pay the school impact fees. Upon review of permit # 7035 discovered hat some of the fees have been paid; water, sewer and public safety paid amount of $3,204.35. mount due currently on the permit is $5,016.28 which consist of school impact ($4,876.28) and our red tags @ $35.00 each*($140.00). e have deducted amount paid wrongfully against the amount that still is outstanding before final nspection $5,016.28- $3,204.35= (balance owe$1,811.93) Fee that have been waived Water connection- $641.00(paid) Sewer connection - $2,010(paid) olice impact-$254.00(paid) Fire impact-$273.00(paid) ublic safety-$26.35(paid) Park Fee-$769.56(not paid) Traffic impact -$1,588(not paid) ee that need to be paid chool,impact-$4,876.28 4) red tag -$140.00 ($35.00 ea.)— notice of corrections/ reinspection fee charge incerely, L( 1 ill Burgess uilding Official B/jb 05/06/2009 _, 4 F ', 0004290 0004290 C. 7 2C Cash 0.-- Check f`. iSL93 Change _,ui LJJ R •,r, E orb t;.7 �1�'il t: t'CC� ERMIT7O35 14000 TRW _t��iit 1....:J a !i � School i73iC+ : FF' r 3po I"t i.C,ii. ° ego F5 PASCO COUNTY, FLORIDA Permit No, ' 1c 5S Date Permitted _T______ Builder Name/Dwner Name 1 In �� A��r 0 ontrol# County Parcel No. \\ i i o O\O. 1 Code SubDiv: Address/Location 5L+ 1 5$ Classification/Type of Use TRANSPORTATION IMPACT FEE Rate: Sq Ft Unit; C�— Exempt ® Yes No How Determined Impact Fee Amount $ _ Zone No.. _ TAZ: SCHOOL iMPACT FEE — Account (056) Single-Family Detached House Amount $ /' .(057) Mobile Home (056)_ Other Residential 0 7 123) Collection Fee Exempt [] Yes No How Determined PARKS AND RECREATION FEE . Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total • Zone TOTAL.AMOUNT•• $ 0 Exempt ❑ Yes ❑ No How.Determined LIBRARY FEE Land Account Land Credit 0 Land Total Facility Account Facility Credit Facility Total 0 • Exempt ❑ Yes . ❑ No How Determined • Total Amount RESOURCE FEE ERU TOTAL AMOUNT 4 . Prepared By Checked By 0 NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND • RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply receipt ate copy of this foram,placing the building permit owner on notice of this assessment and the conditions of payment for same. :4 DATE RECEIVED BY RECEIPT NO. DATE BY February 12, 2009 RE: Permit 7035 To Whom It May Concern: We own the property at 5541 13°i St. and would like to know what our impact fees are going to he. When we purchased the property we were informed that there already had been structures on the property, water meter, etc. We were advised many of the impact fees were paid and therefore would be waived for us. We obtained copies of the parcel cards from the County Courthouse in Dade City. The parcel cards are attached to this letter for our Parcel 11 26 21 0010 11600 0090. The cards show that there were homes on the property in 1986. Please review these parcel cards and calculate the impact fees we owe. We appreciate your time and consideration in this matter. Our phone number is 813-782-8944, FAX number 813-315-6461. mailing address: 31536 Stirrup Ln Wesley Chapel, Fl 33543. Sincerely, John and Peggy Mulligan , '�rR._—.tt4y•! ! ri.�eL� _ � ----..'•' ._. Lam,- — i I ________________________________________ w . I DIA KET TAX AREA CODE — 30ZH C0iJ TY OF PASCO 12/30'8 E 7 2 SEC NP RGE SUE) ELK./PAR LOIIC.O. 11 26 21 0010 11500 0090 APPRAISED BY CELT ON 02129/84 CARD 2 is 2 COST MAI�ET DgTA2L c0ST-MARK T YALUE CEP !OAT"I VALUE SUUMAYT eo.+v+xc s..ir.+ h..+e. ev. cc c. I..7(+ 5 AVERAGE 66 i MARKET L __ — SCR CONSTRUCTION ra..ara os.f•.a� i 4' = tS:'L.LE !'S Y R:St hTIAL 1GA3LE OR NIP (SCALE 1 113E tars uwo mw 1 4IN. R"OFYNE—CORRJ ratst,.ro<uct�mcu:. ..t..w a liA — $ :A RD OR WOOL : '-----------'---+ PINE OR SOF: i.'OODS IEAS IFE I 1 I mw wGwC fto.r.tAXL.tD 1 T0S.[wCNC1iTY.#.M:IrJI,fCFI 3 NONE 1 I rascGat+..mrsrs._r.^ I ¢;?y a,aon+c 1 '�FO NE j I I i tors caw u.acrt rwta f."t i 17 ?_'C� .. �-« 1 IN NEE DETAK!FC7Pt SlELLs3!WO©ELS I I I �- INCOME VALuA ON STORIES 1 X1.0 STORIES T 1 At£iK O 1 M i I Gaoaswwu.s..:owa 1 ---------- 1 I AOOrtiONAt CAETALL i I n, s 9 --- ----------- ATM 1. .0 1 +c+.w.ufccrs 4-- fc+ rss I ,. raoo G+ WARD LLS'.gw I ,, I I f � i FER 6 AS� 5910t $91 7,741� i 1 JSFI 1&O3 1& 03C 49 63€1 I f I I i!COME VALUE I _ I •to 8, 3 r tMMKf ± --n t { ��` I i F cP=WZeAG=17 S3.E2I'SF=S,L�E h4 l ,b_F,hV day I i ` ! ;1OSS1OE4N1OSS. TOTAL Oi!%F VALUE , +a - ' •.ti3 S.a? 3 t0C.I bi .'+C?t .e^S�^'�.MR^., 1CR4 C 1.9'rt I R re.:. r►wf•ftE '�• • ! f i Kw:.': La..S..M'. _._ -..... .-....—.. f ._....�-.-_.-- 1...-.-.__-. TAY AfizA C,C?:+� {{1 N•" 0i PAS'=' 12?2f+1P4 0 2 C TWP 06E ri",� O; a `i`A1 L .�Y. 11 26 21 (010' 11A0tI 1(- APPRAISED Y K ON '9 8 _ - wchtm IF COiT Tvt)C:T7Cit1!*TA1L COST-wLA1�EET VALUE I p QTIO4 YALLF 3+sASNA1## o,e.�.; t'oweaw.e aw tt*s r++,w. .rat n!sr rsw r.e wan. cma+. aw.+xw.rrw vn.n+Kart _ : .�t I.ocr vw,cgw - Lt O. N CA1.` [, 1 `n«..e+ .+tw+�rtr +rw cep i. OR CO! O5 0! I6O I z `------------` awn nas,o , g N_ OR SOFT WC P 1 UT'G I .�n.a a.sr.ct a*xe r i i w cta++__ .n_ __ ! „ t,.T i?LTAA spec tI MSS { i INCOME VALIJAT'O t S OAIES #�: 1.CI STO.gIES - `------------` ToTJLL 01J xf vAlUE t° xtRe rolls aW ork..aM, tatu M,la i `100.2.49 iYM. YM Wn 1 Drat IKE t ,.bt! .awa.a�i� J L ____ - ___________ _______ - ____ ____ ____ rot"awrxat MARKET LAX AREA CODE - 30ZH COUNTY OF PASCO 12/30/86 D 0 2 SEC TWP RGE SUED BLK/PAR LOT/C.O. 11 26 21 0010 11600 0090 APPRAISED BY CELK ON 02!29/84 CARD 1 OF 2 8642 CC$VMamm CONSTRUCTION CET CT-MAT VALUE IDeMECAMIN4 VALUE SUMMARY Itlttlq i9.0.ftlCO�ixtr eM a4Jt Qtt.co$1.ew 1I.IrI %co-G, ofE.ewwa ftitcara rutA :�z.. maa 't05 WERAGE K11 23 613.5 31?15I45320DOt' ir"wtq.r aT SINGLE FA??ILY RESIDENTIAL - SFR CONSTRUCTION totuaat-oanruw __________ 6149 sa,civaiI0 GABLE OR HIP SCALE 1/120 ro"tt""a•"'t'f'•aaieT 10 cavek3 SPHALT OR COMPOS B E ALL BOARD OP WOO E fl NE OR SOFT WOOD O wtt CM"A4. a tut Vol".osctfu vaWFC.AT rot"11041- l`A r"te.eafctt n,o nM 1 NONE roru cofra,aff[r vwa caea 12,515 GE+x 1 NONE ears t,.e 1 f rot"costv,aaftr vatu:earn DETAIL FOR SPECIAL MODELS IN-_0ME VALUATION STORIES mi 1.0 STORIES METHOD K cao TI[*<T&Mt!O33 ADDfVNM DETAIL HIED o.Ef"r+G f m& 11` �----------_1 BATH eoEtvE.oe Mr. _ .ar aEwu v.ca.t I fDfu .CE ATtu rK_ !«!"! CrDl4 O � cm r ' .ea wf "e. "]]��j +.------------+ - 1 8s 23 1 23A ISAS I I I I I i f I f ! 1 ' I NCOME VAWE { I I t w acorn wE I T r I I ( ► � I I -------------* - •K>iFs d r ...vu" .[t ofva aEae ne ar+o f..Kbt 1 ' » a^tfCnsr ar Ja•s vw."Z r'v tfR uVF f { fat[ TOM Rf VALUE tarp !^,W OEX :l.w`.•tcF nr!+acs f a..o 'f.'!C.. •�}a.aG.Is7l.agF G[+'•1 - taro Vvrls '.jT.. ' i :} }} IL h 1J _-Laos R .. �'•. �t�l;71 �....__.,..j MAR!:t-.._.._ Ttt-.._ i?':1,�� TAX AREA CODE — 307H COU-4TY OF PASCO 121301.85 E 0 2 S€C TWP RGE SUED SLK/PAR L0T/C.0. 11 26 21 0010 11600 00`10 APPRAISED BY C€I. ON 02/29/84. CARD 2 OF 2 `(6 T COME R7Cf7QM DEfA� I ID 'faEOA' VALUE WJ*A%An E.elEbet ciT+awc*tJt flETaa E.e aa%. wE Qe' •a'ar. 1cc. IflrR!Akwe ffna.'9*uyf rws ' WERAGE 87JcI TT nor+tcw tr ,Ru Y 7 r ►4Lf 44M LY C L - S•R CONSTRUCTION *ae �eT __ fEeeerfto L H'I SCALE 1/130 Tat"wevaueww_ E R^ fI -CORRRJ to'u!'"°' 45 WALLAR3R 1304 +-----------+---. E.T.csse. NE OR SOFT 1r'COD !OAS iFEri "c°"e""E4•O •"' ________________ i I I l,waaEecwroaa.,,,ves.o 1 {HIE { I Wlax+*a'vE 1 't!iE I I I *^a,cas*.uss.+rT.c c.a^ &,701 'at tr+t xq Yl I 'tO1'f I i *ora!tar..+•.n«r.w-> 71,+ti L i ��DETaI}L FL^M A2 wJ©F35 --` t P4COME t1ALUATvON CITY OF / / BUILDING ZEPHYRHILLSOT I C DEPARTMENT OF ADDITION OR CORRECTION N ADDRESS DATE PERMIT,fir d 35_ (�. THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be mode before the job will be accepted. i) / 4?J iV ( Plcrf-es (a z) 1J .uJ i-c ' oT A J yL 1) jud h kk 'c O ' Fe f ;'\ (( C7 (iL ( pp( 9ti1- 1( 11t It is unlawful for t4 Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS A E MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FO E-I PECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30 AM-5 PM MON.-FRI. INSPECTOR CITY OF / / / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION ADDRESS DATE PERMIT[cc r . THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. c ? -a ô -g / 111 1V- i2i nr2SicUi 41 vt iLs.it C f Th c2 ? h¼ ) s s c; 34t W L 1 ice & s I7r2P It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSPECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR ) 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department b�11 Date Received T_ -07IPhone Contact for Permittin ' 7 g t Owner's Namef_ ' Mh) ` Owner Phone Number 17PftZ Owner's Address 3i 5 s't Ltv. Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 5`A I �l 3\cPe (I7 AU I1 LOT# SUBDIVISION PARCEL ID# OU/�-//6vD (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED B NEW CONSTR B ADD/ALT SIGN Q MOVE Q DEMOLISH INSTALL REPAIR PROPOSED USE 0 SFR Q COMM Q OTHER TYPE OF CONSTRUCTION BLOCK 0 FRAME Q STEEL Q OTHER DESCRIPTION OF WORK O BUILDING SIZE \ SQ FOOTAGE HEIGHT } . BUILDING $ VALUATION OF TOTAL CONSTRUCTION LY ELECTRICAL $ AMP SERVICE 0 PROGRESS ENERGY Q W.R.E.C, PLUMBING $ �\ MECHANICAL $ V VALUATION OF MECHANICAL INSTALLATION Lc- .6�\c - ✓ 0 GAS E ROOFING 0 SPECIALTY Q OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA Eli YES LJNd lIllIllIllIl IIIIIIIIIlII,JI ;?I_IlIllIllIllIlI_IllIllIlIllIll_IllIllIllIll III 11111 III 11111 IllIllIlIllIllIl III III IlIllIlIlIlIll 111111 BUILDER /_Z _,-: COMPANY ,n SIGNATURE REGISTERED / FEE CURRENT /N Address l i• ? _? ?14'' I n License# 'S $ % 3 / ELECTRICIAN COMPANY ��I12 _ SIGNATURE REGISTERED I(V..NI FEE CURRENT I d _N Address g License# :'Q "c� PLUMBER COMPANY It7/A) /0 r`— SIGNATURE REGISTERED V_Y/ NI FEE CURRENT Y/N Address _64tó4&.' License# MECHANICAL COMPANY Li✓`Jr48�e: ,j __ SIGNATURE Qy ' 'a hREGISTERED I / N I FEE CUn+.crvi w Y/ Address License# UQ,0664 OTHER COMPANY SIGNATURE REGISTERED Y INI FEE CURRENT Y/N Address License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Sanitary Facilities&I dumpster COMMERCIAL Attach(3)sets of Building Plans;(1)set of Energy Forms. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Sanitary Facilities&1 dumpster All commercial requirements must meet compliance. SIGN PERMIT Attach( �etspf.Engineered-Plans. ***'PROPERTY SURVEY required for.all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$5000) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways Not ovPY Cburiter4f on prb4c roadways..needs ROW - NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone"V"unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill matterial a to be ,�rl any area, I certify that use of such fill will not adversely affect adjacent properties.' If of fill is fotin21 to adversely affect adjacent'properties, the owner niay"be cited for violating the conditions of the building permit issued under the attached\p it pplicatibn, fb.r lots less than one (1) àcrv.hct are elevated by fill, an engineered drdinage.!lin t$required._, . . , , If I am the AGENT FOR THE OWNER, I promise in good faith to into&ni the ownerf cont iifions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR N ICE Of COIfENCE T. FLORIDA JURAT(F.S. 117.0 )//y OWNER OR AGENT CONTRACTOR Subscribed and sworn toedT6ore me this Subscribed and ssw n�to(oorafri ed)be ore me this by by Who is/ar personall nown to me or has/have produced Who is/are personally known to me or has/have produced as identification. as identification. _______________________________Notary Public U_ _____________ Notary Public Commission No. Commission No. Name of Notary Name of Notary typed,printed or sta "''a Nala1Y Pubic.lk�le of Ffpklo \�P,,,, MARTHA SMITH poinribnBrnl�t0rlc2&J= Ak ` ¢:Ncfory Public-State of Floddo cownwdon#DD 349786 .��° AyCamnibnlB{rim0ec2a,7A� ", la�tMdMNalonalNo"V 's, Ia;� C Commkdon#t DO 349785 landed a Nalond Notary Aim. I I SCALE: 1" = 30' I I 0' 30' 60' I -J I--------------------------------------a I I I I 4 II I I S z II I I 11 140' (R) S 64'51'12" W. - 140.03' (M) 1 rt{. 1.-I „ 1 0 0 I I -1 52.0' 68.0 20.0' % I I M o PROPOSED RESIDENCE 19 T --------------- ---------- 1 o+ rri N 6.0 O N N I 1 I 46.3' 33.6' I I J 140' (R) S. 64'49'40" W. - 140.03' (M) I � o 7th AVENUE 60 -RIGHT OF WAY 2O ASPHALT PA'ZEKMNT ------------------------------------ REV IE! / rAY ' 10f7_ CIT ILLS PLC„,a ' =� v��or [(c LY WTTIALL . il#� rya NOTES: con ' Bounary information shown hereon is based on a survey Boundary Surveq•'1� CODE AND #W07-0306, dated 3/23/2007. ANDES Subject Parcel is Zoned R2-setback requirements are 20'front, 10'side and rear. Subject Parcel is in Zone "X"areas outside of the 500 year flood plain, according to the FEMA/FIRM community panel number: 120235 0005 C, dated December 17, 1991. LEGAL DESCRIPTION Lots 9 & 10 Block 116 of TOWN OF ZEPHYRHILLS, as recorded in Plat Book 1, Page 54 of the public records of Pasco County, Florida. REVISION DATE DESCRIPTION SITE PLAN Client: Perillo & Associates Work order number: W07-0306 Date of Plan: 04/05/2007 PA GE SECTION ii ' OF 1 TOWNSHIP 26 S. RANGE 21 E. PASCO COUNTY, FLORIDA Sep 10 07 10:55a p.1 SEP/0?/2007/FRI 02:27 PM ZEPHYRIILLS BUILDING FAX No.813-780-0021 P.001 eaaficj- • - - -ac.=. City.of:Zc& In'll1s—Building Dept Phone:(813)-78.0.0020 . •PAX:(813)-780-0021 Date: 9-7-07 . Jydy/Gail ?(sett-• kmi l ler®ci eohvthills.fl.us FAX#: - 727-815-7000 #PAGES: 2- . • MESSAGE: Hope your day is SAS GREAT. We have a project which we need an address for. Listed below is the information concerning it If you have any questions, p1 sac contact mc. Tback you _ Parcel: 11-26-21-0010=11600=0090 ' . _ Type: • : X Reswenllal O:eumraeciai O'other Lot Number: 9 Stet Pacing:-13"Stroll y'ov saw// Sep 10 07 10:56a p.2 SEP/07/2007/FRI 02:27 PM ZEPHYRHILLS BUILDING FAI No- 813-780-0021 P. 002 I SCALE: 1"• 30* . I I If I L---------¶.._____-?.------------------- S a1,0•(R) S EYat•12-W.— 140.0]'M• 1 ¢ 1 1..1^ !nA 1• n wQ a.o Y,n 1 4 2DA' J 4 g -------�-- --- —p ---RESWLNCC^ t T �$ of i 1 � F n f 21' • 7� 140• (R) R sc4S'40•N.- 140.OY M - I S ----------------- ----- NOTES: gounary Infomlabon shown herson Is based on a survey Boundary Survey by John Walsh.order #V1107-0306,doled 3/232007. . • Subject Parcel Is Zoned R2-setback requirements are 20'front,10'side end rear. . Subject Parcetle-Intone Or trot's outside'of the 500'year Nood plain.a 000rdit'lo'the• FEMMFIRM communIty panel number:1 )2350005C,dalsd December 17.1891. LEGAL DESCRIPTION • 'Lots 9&10 Block 116 of TOWN•OF ZEPHYRIBLLS,as recorded in Plat Book.1,. Paage 54 of the public records of Pasco County,Florida IILMSION 0117[ ORfdtlP0ON ,ATE PLAN. o Pertllo & Asaacletea Work order numbs: 007-0306 1Date of Plea: 04/06/2007 PAGE SacTION f f • . . TOWNSHIP 26-S' RANdd OF 1';_ PASCO COUNTY, FLORIDA ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* =87.3 The higher the score,the more efficient the home. RELIANCE HEATING &AIR, , , , I. New construction or existing New _ 12. Cooling systems 2. Single family or multi-family Single family _ a. Central Unit Cap:40.5 kBtu/hr 3. Number of units,if multi-family 1 _ SEER: 13.00 4. Number of Bedrooms 4 b. N/A 5. Is this a worst case? Yes 6. Conditioned floor area(ft') 1800 ft2 c. N/A 7. Glass type'and area:(Label reqd.by 13-104.4.5 if not default) a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a(Sngle Default) 168.9 ft2 _ a. Electric Heat Pump Cap:42.5 kBtu/hr b. SHGC: HSPF:8.10 _ (Clear)168.9 ft2 b. N/A (or Clear or Tint DEFAULT) 7b. _ 8. Floor types a. Slab-On-Grade Edge Insulation R=0.0, 182.0(p)ft c. N/A b. N/A c. N/A 14. Hot water systems 9. Wall types a. Electric Resistance Cap:40.0 gallons _ a. Concrete,Ext Insul,Exterior R=4.2, 1660.0 ft2 _ EF:0.92 b. Frame,Wood,Adjacent R=11.0, 160.0 ft2 b. N/A c. N/A d. N/A _ c. Conservation credits e. N/A _ (HR-Heat recovery,Solar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=19.0, 1800.0 ft2 _ 15. HVAC credits PT, _ b. N/A — (CF-Ceiling fan,CV-Cross ventilation, c. N/A _ HF-Whole house fan, 11. Ducts PT-Programmable Thermostat, a. Sup:Unc. Ret:Unc. AH:Interior Sup.R=6.0,75.0 ft _ MZ-C-Multizone cooling, b. N/A — MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed(or exceeded) ,,yyo1Zl sTtT�o in this home before final in pection. Otherwi e,a new EPL Display Card will be completed based on installed Code plia t feat a ���„ "„ Builder Signature: Date:_�=i ��s� a Address of New Home: I City/FL Zip: oD�� *NOTE: The home's estimated energy performance score is only available through the FLA/RES computer program. This is not a Building Energy Rating. If your score is 80 or greater(or 86 for a US EPA/DOE EnergyStar'7'designation), your home may qualfr for energy efficiency mortgage(EEM) incentives([you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site at www.fsec.ucfedu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850/487-1824. 1 Predominant glass type.For actual glass type and areas see Summer&Winter Glass output on ages 2&4. 1 nergyGauge®(Version: FLRCPB v4.5) Residential System Sizing Calculation Summary RELIANCE HEATING &AIR Project Title: Code Only 1800 - Perrillo Homesite Professional Version Climate: Central 3/19/2007 Location for weather data: Tampa - Defaults: Latitude(28) Altitude(19 ft.) Temp Range(M) Humidity data: Interior RH 50% Outdoor wet bulb 77F Humidity difference(56gr.) Winter design temperature 40 F Summer design temperature 91 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 30 F Summer temperature difference 16 F Total heating load calculation 27677 Btuh Total cooling load calculation 25828 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh Total (Electric Heat Pump) 153.6 42500 Sensible (SHR = 0.75) 137.8 30375 Heat Pump +Auxiliary(0.0kW) 153.6 42500 Latent 267.2 10125 Total (Electric Heat Pump) 156.8 40500 WINTER CALCULATIONS Winter Heating Load (for 1800 s ft Load component Load Window total 169 sqft 6433 Btuh 4 pt Wall total 1820 sqft 7600 Btuh Door total 48 sqft 604 Btuh Ceiling total 1800 sqft 2647 Btuh Floor total 182 sqft 6443 Btuh Infiltration 107 cfm 3534 Btuh Duct loss 416 Btuh Subtotal 27677 Btuh Ventilation 0 cfm 0 Btuh TOTAL HEAT LOSS 27677 Btuh SUMMER CALCULATIONS Summer Cooling Load (for 1800 s ft Load component Load Window total 169 sqft 7234 Btuh Wall total 1820 sqft 4125 Btuh Door total 48 sqft 544 Btuh ,t„ ;,; „e,,;<,v�. Ceiling total 1800 sqft 2294 Btuh Floor total 0 Btuh Infiltration 56 cfm 992 Btuh Internal gain 6475 Btuh Duct gain 375 Btuh Sens. Ventilation 0 cfm 0 Btuh Total sensible gain 22038 Btuh Latent gain(ducts) 243 Btuh -�i5_°T� ,:,,,�u. Latent gain(infiltration) 2146 Btuh Latent gain(ventilation) 0 Btuh Latent gain(internal/occupants/other) 1400 Btuh Total latent gain 3790 Btuh TOTAL HEAT GAIN 25828 Btuh EnergyGauge®System Sizing Version 8 PREPARED BY: For Florida residences only DATE: D? EnergyGauge® FLRCPB v4.5 FORM 600A-2004R EnergyGauge®4.5 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: BASE AS-BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 4 2460.00 9840.0 40.0 0.92 4 1.00 2460.00 1.00 9840.0 As-Built Total: 9840.0 CODE COMPLIANCE STATUS BASE AS-BUILT Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 11418 3926 9840 25184 9460 3793 9840 23093 PASS �O4ZHESr4jp, t j�CODWE ��S EnergyGaugeTM DCA Form 600A-2004R EnergyGauge®/FIaRES'2004 FLRCPB v4.5 FORM 600A-2004R EnergyGauge®4.5 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 1800.0 24.35 7889.0 1.Single,Clear W 5.0 2.0 4.5 57.68 0.40 103.0 2.Single,Clear W 5.0 8.0 8.5 57.68 0.67 326.0 3.Single,Clear W 1.0 0.0 19.5 57.68 0.39 440.0 4.Single, Clear N 1.0 0.0 5.3 30.19 0.61 98.0 5.Single,Clear N 0.0 0.0 14.3 30.19 1.00 432.0 6.Single,Clear E 6.0 26.0 14.3 63.97 0.93 852.0 7.Single,Clear E 6.0 26.0 72.0 63.97 0.93 4281.0 8.Single,Clear E 0.0 0.0 14.3 63.97 1.00 916.0 9.Single,Clear S 0.0 0.0 5.3 48.22 1.00 257.0 10.Single,Clear S 1.0 0.0 10.8 48.22 0.48 246.0 As-Built Total: 168.9 7951.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 160.0 0.70 112.0 1.Concrete, Ext Insul, Exterior 4.2 1660.0 0.46 763.6 Exterior 1660.0 1.90 3154.0 2. Frame,Wood,Adjacent 11.0 160.0 0.70 112.0 Base Total: 1820.0 3266.0 As-Built Total: 1820.0 875.6 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 17.7 1.60 28.3 1.Exterior Insulated 30.2 4.80 144.9 Exterior 30.2 4.80 144.9 2.Adjacent Wood 17.7 2.40 42.5 Base Total: 47.9 173.3 As-Built Total: 47.9 187.5 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1800.0 2.13 3834.0 1. Under Attic 19.0 1800.0 2.82 X 1.00 5076.0 Base Total: 1800.0 3834.0 As-Built Total: 1800.0 5076.0 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 182.0(p) -31.8 -5787.6 1.Slab-On-Grade Edge Insulation 0.0 182.0(p -31.90 -5805.8 Raised 0.0 0.00 0.0 Base Total: -5787.6 As-Built Total: 182.0 -5805.8 INFILTRATION Area X BSPM = Points Area X SPM = Points 1800.0 14.31 25758.0 1800.0 14.31 25758.0 EnergyGauge®DCA Form 600A-2004R EnergyGauge®/FlaRES'2004 FLRCPB v4.5 FORM 600A-2004R EnergyGauge®4.5 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: BASE AS-BUILT Summer Base Points: 35132.7 Summer As-Built Points: 34042.3 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1:Central Unit 40500btuh,SEER/EFF(13.0)Ducts:Unc(S),Unc(R),Int(AH),R6.0(INS) 34042 1.00 (1.09x 1.150x0.90)0.90) 0.260 0.950 9459.9 35132.7 0.3250 11418.1 34042.3 1.00 1.125 0.260 0.950 9459.9 EnergyGaugeTM DCA Form 600A-2004R EnergyGauge®/FlaRES'2004 FLRCPB v4.5 FORM 600A-2004R EnergyGauge® 4.5 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 1800.0 9.11 2952.0 1.Single,Clear W 5.0 2.0 4.5 13.25 1.11 66.0 2.Single,Clear W 5.0 8.0 8.5 13.25 1.06 118.0 3.Single,Clear W 1.0 0.0 19.5 13.25 1.12 288.0 4.Single,Clear N 1.0 0.0 5.3 15.07 0.98 79.0 5.Single,Clear N 0.0 0.0 14.3 15.07 1.00 215.0 6.Single,Clear E 6.0 26.0 14.3 12.37 1.02 180.0 7.Single,Clear E 6.0 26.0 72.0 12.37 1.02 904.0 8.Single,Clear E 0.0 0.0 14.3 12.37 1.00 177.0 9.Single,Clear S 0.0 0.0 5.3 9.90 1.00 52.0 10.Single,Clear S 1.0 0.0 10.8 9.90 2.29 243.0 As-Built Total: 168.9 2322.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 160.0 1.80 288.0 1.Concrete, Ext Insul, Exterior 4.2 1660.0 2.32 3851.2 Exterior 1660.0 2.00 3320.0 2. Frame,Wood,Adjacent 11.0 160.0 1.80 288.0 Base Total: 1820.0 3608.0 As-Built Total: 1820.0 4139.2 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 17.7 4.00 70.9 1.Exterior Insulated 30.2 5.10 154.0 Exterior 30.2 5.10 154.0 2.Adjacent Wood 17.7 5.90 104.5 Base Total: 47.9 224.9 As-Built Total: 47.9 258.5 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1800.0 0.64 1152.0 1. Under Attic 19.0 1800.0 0.87 X 1.00 1566.0 Base Total: 1800.0 1152.0 As-Built Total: 1800.0 1566.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 182.0(p) -1.9 -345.8 1.Slab-On-Grade Edge Insulation 0.0 182.0(p 2.50 455.0 Raised 0.0 0.00 0.0 Base Total: -345.8 As-Built Total: 182.0 455.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 1800.0 -0.28 -504.0 1800.0 -0.28 -504.0 EnergyGauge®DCA Form 600A-2004R EnergyGauge®/FlaRES'2004 FLRCPB v4.5 FORM 600A-2004R EnergyGauge®4.5 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: BASE AS-BUILT Winter Base Points: 7087.1 Winter As-Built Points: 8236.7 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 42500 btuh ,EFF(8.1)Ducts:Unc(S),Unc(R),Int(AH),R6.0 8236.7 1.000 (1.078 x 1.160 x 0.92)0.421 0.950 3793.1 7087.1 0.5540 3926.2 8236.7 1.00 1.150 0.421 0.950 3793.1 EnergyGaugeT^" DCA Form 600A-2004R EnergyGauge®/FIaRES'2004 FLRCPB v4.5 FORM 600A-2004R EnergyGauge®4.5 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS LSECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows&Doors 606.1.ABC.1.1 Maximum..3 cfm/sq.ft.window area; .5 cfm/sq_ft.door area Exterior&Adjacent Walls 606.1.ABC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall; foundation&wall sole or sill plate;joints between exterior wall panels at corners; utility penetrations;between wall panels&top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from,and is sealed to,the foundation to the p te. Floors 606.1.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members. EXCEPTION:Frame floors where a continuous infiltration barrier is installed that is sealed to the_perimeter,penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls&ceilings; penetrations of ceiling plane of top floor;around shafts,chases, soffits,chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter,at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated, installed inside a sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from conditioned space,tested. Multi-storyHouses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2.Switch or clearly marked cir breaker(electr r cutoff�ga�must be provided. External or built-in heat trap required. Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated). Non-commercial pools must have a pump timer.Gas spa&pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts,fittings, mechanical equipment and plenum chambers shall be mechanically attached,sealed, insulated,and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics:R-6 min. insulation. HVAC Controls 607.1 -Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1,602.1 Ceilings-Min. R-19.Common walls-Frame R-11 or CBS R-3 both sides. Common ceiling&floors R-1 1. EnergyGaugeTM' DCA Form 600A-2004R EnergyGauge®/FIaRES'2004 FLRCPB v4.5 System Sizing Calculations - Winter Residential Load - Whole House Component Details RELIANCE HEATING &AIR Project Title: Code Only 1800- Perrillo Homesite Professional Version Climate: Central Reference City: Tampa (Defaults) Winter Temperature Difference: 30.0 F 3/19/2007 This calculation is for Worst Case.The house has been rotated 315 degrees. Window Panes/SHGC/Frame/U Orientation Area s ft X HTM= Load 1 1, Clear, Metal, 1.27 SE 4.5 38.1 171 Btuh 2 1, Clear, Metal, 1.27 SE 8.5 38.1 322 Btuh 3 1, Clear, Metal, 1.27 SE 19.5 38.1 743 Btuh 4 1, Clear, Metal, 1.27 SW 5.3 38.1 203 Btuh 5 1, Clear, Metal, 1.27 SW 14.3 38.1 546 Btuh 6 1, Clear, Metal, 1.27 NW 14.3 38.1 546 Btuh 7 1, Clear, Metal, 1.27 NW 72.0 38.1 2743 Btuh 8 1, Clear, Metal, 1.27 NW 14.3 38.1 546 Btuh 9 1, Clear, Metal, 1.27 NE 5.3 38.1 203 Btuh 10 1, Clear, Metal, 1.27 NE 10.8 38.1 410 Btuh Window Total 169 s ft 6433 Btuh Walls Type R-Value Area X HTM= Load 1 Concrete Blk,Hollow- Ext(0.14) 4.2 1660 4.3 7145 Btuh 2 Frame-Wood -Adj(0.09) 11.0 160 2.8 455 Btuh Wall Total 1820 7600 Btuh Doors Type Area X HTM= Load 1 Wood -Adjacent 18 16.2 287 Btuh 2 Insulated - Exterior 30 10.5 317 Btuh Door Total 48 604Btuh Ceilings Type/Color/Surface R-Value Area X HTM= Load 1 Vented Attic/L/Tile 19.0 1800 1.5 2647 Btuh Ceiling Total 1800 2647Btuh Floors Type R-Value Size X HTM= Load 1 Slab On Grade 0 182.0 ft(p) 35.4 6443 Btuh Floor Total 182 6443 Btuh Envelope Subtotal: 23727 Btuh Infiltration Type ACH X Volume(cuft)walls(sqft) CFM= Natural 0.38 16920 1820 107.2 3534 Btuh Ductload (DLM of 0.015) 416 Btuh All Zones Sensible Subtotal All Zones 27677 Btuh EnergyGauge® FLRCPB v4.5 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) RELIANCE HEATING &AIR Project Title: Code Only 1800- Perrillo Homesite Professional Version Climate: Central 3/19/2007 NHOLE HOUSE TOTALS< /E ,Y_;�6 �C 9/ '� _ &6E ape.of4 ff �€�I�C�E° e� _ E f�'£ Subtotal Sensible 27677 Btuh Ventilation Sensible 0 Btuh Total Btuh Loss 27677 Btuh EQUIPMENT .✓f 3 kqi W _ J�Sfk E P aS 2 �.-f < ,� f.«/ . „v. ..�lia'e B I' .FF vi ,A✓,�., k 9 1. Electric Heat Pump # 42500 Btuh Key:Window types(SHGC-Shading coefficient of glass as SHGC numerical value or as clear or tint) (Frame types-metal,wood or insulated metal) (U-Window U-Factor or'DEF'for default) `f (HTM-ManualJ Heat Transfer Multiplier) Key: Floor size(perimeter(p)for slab-on-grade or area for all other floor types) Version 8 For Florida residences only EnergyGauge® FLRCPB v4.5 Page 2 System Sizing Calculations - Winter Residential Load - Room by Room Component Details RELIANCE HEATING &AIR Project Title: Code Only 1800- Perrillo Homesite Professional Version Climate: Central Reference City: Tampa (Defaults) Winter Temperature Difference: 30.0 F 3/19/2007 This calculation is for Worst Case.The house has been rotated 315 degrees. Window Panes/SHGC/Frame/U Orientation Area s ft X HTM= Load 1 1, Clear, Metal, 1.27 SE 4.5 38.1 171 Btuh 2 1, Clear, Metal, 1.27 SE 8.5 38.1 322 Btuh 3 1, Clear, Metal, 1.27 SE 19.5 38.1 743 Btuh 4 1, Clear, Metal, 1.27 SW 5.3 38.1 203 Btuh 5 1, Clear, Metal, 1.27 SW 14.3 38.1 546 Btuh 6 1, Clear, Metal, 1.27 NW 14.3 38.1 546 Btuh 7 1, Clear, Metal, 1.27 NW 72.0 38.1 2743 Btuh 8 1, Clear, Metal, 1.27 NW 14.3 38.1 546 Btuh 9 1, Clear, Metal, 1.27 NE 5.3 38.1 203 Btuh 10 1, Clear, Metal, 1.27 NE 10.8 38.1 410 Btuh Window Total 169 s ft 6433 Btuh Walls Type R-Value Area X HTM= Load 1 Concrete Blk,Hollow- Ext(0.14) 4.2 1660 4.3 7145 Btuh 2 Frame-Wood -Adj(0.09) 11.0 160 2.8 455 Btuh Wall Total 1820 7600 Btuh Doors Type Area X HTM= Load 1 Wood -Adjacent 18 16.2 287 Btuh 2 Insulated - Exterior 30 10.5 317 Btuh Door Total 48 604Btuh Ceilings Type/Color/Surface R-Value Area X HTM= Load 1 Vented Attic/L/Tile 19.0 1800 1.5 2647 Btuh Ceiling Total 1800 2647Btuh Floors Type R-Value Size X HTM= Load 1 Slab On Grade 0 182.0 ft(p) 35.4 6443 Btuh Floor Total 182 6443 Btuh Zone Envelope Subtotal: 23727 Btuh Infiltration Type ACH X Volume(cuft)walls(sqft) CFM= Natural 0.38 16920 1820 107.2 3534 Btuh Ductload Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DLM of 0.015) 416 Btuh Zone#1 Sensible Zone Subtotal 27677 Btuh EnergyGauge® FLRCPB v4.5 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) RELIANCE HEATING &AIR Project Title: Code Only 1800 - Perrillo Homesite Professional Version Climate: Central 3/19/2007 HOLE HOUSE TOTALS I Subtotal Sensible 27677 Btuh Ventilation Sensible 0 Btuh Total Btuh Loss 27677 Btuh EQUIPMENT � � @€s j '€ - € c _ ����S9a ai` 1. Electric Heat Pump # 42500 Btuh Key:Window types(SHGC-Shading coefficient of glass as SHGC numerical value or as clear or tint) (Frame types-metal,wood or insulated metal) (U-Window U-Factor or'DEF'for default) (HTM-ManualJ Heat Transfer Multiplier) Key: Floor size(perimeter(p)for slab-on-grade or area for all other floor types) Version 8 For Florida residences only EnergyGauge® FLRCPB v4.5 Page 2 System Sizing Calculations - Summer Residential Load - Whole House Component Details RELIANCE HEATING &AIR Project Title: Code Only 1800- Perrillo Homesite Professional Version Climate: Central Reference City: Tampa (Defaults) Summer Temperature Difference: 16.0 F 3/19/2007 This calculation is for Worst Case.The house has been rotated 315 degrees. ( 4 Type* Overhang Window Area s ft) HTM Load Window Pn/SHGC/U/InSh/ExSh/IS Ornt Len H t Gross Shaded Unshade _- 1 1,Clear, 1.27, B-M, N,H SE 5ft. 2ft. 4.5 4.5 0.0 Sh25ed Unshaded r 113 Btuh 2 1,Clear, 1.27, B-M, N,H SE 5ft. 8ft. 8.5 8.5 0.0 25 50 214 Btuh 3 1,Clear, 1.27, B-M,N,H SE 1ft. Oft. 19.5 19.5 0.0 25 50 492 Btuh 4 1,Clear, 1.27, B-M, N,H SW 1ft. Oft. 5.3 5.3 0.0 25 50 135 Btuh 5 1,Clear, 1.27, B-M, N,H SW Oft. Oft. 14.3 0.0 14.3 25 50 715 Btuh 6 1,Clear, 1.27,B-M, N,H NW 6ft. 26ft. 14.3 0.0 14.3 25 48 683 Btuh 7 1, Clear, 1.27, B-M, N,H NW 6ft. 26ft. 72.0 0.0 72.0 25 48 3432 Btuh 8 1,Clear, 1.27, B-M, N,H NW ' Oft. Oft. 14.3 0.0 14.3 25 48 683 Btuh 9 1,Clear, 1.27, B-M,N,H NE Oft. Oft. 5.3 0.0 5.3 25 48 254 Btuh 10 1,Clear, 1.27, B-M, N,H NE lft. Oft. 10.8 0.0 10.8 25 48 512 Btuh Window Total 169 (sgft) 7234 Btuh Walls Type R-Value/U-Value Area(sqft) HTM Load 1 Concrete Blk,Hollow-Ext 4.2/0.14 1660.0 2.3 3882 Btuh 2 Frame-Wood-Adj 11.0/0.09 160.0 1.5 243 Btuh Wall Total 1820 (sqft) 4125 Btuh Doors Type Area (sgft) HTM Load 1 Wood-Adjacent 17.7 14.6 258 Btuh 2 Insulated-Exterior 30.2 9.4 285 Btuh Door Total 48 (sgft) 544 Btuh Ceilings Type/Color/Surface R-Value Area(sqft) HTM Load 1 Vented Attic/Light/Tile 19.0 1800.0 1.3 2294 Btuh Ceiling Total 1800 (sgft) 2294 Btuh Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 182(ft(p)) 0.0 0 Btuh Floor Total 182.0 (sgft) 0 Btuh Envelope Subtotal: 14196 Btuh Infiltration Type ACH Volume(cuft)wall area(sqft) CFM= Load SensibleNatural 0.20 16920 1820 107.2 992 Btuh Internal Occupants Btuh/occupant Appliance Load gain 4 X 230 + 5555 --- 6475 Btuh Sensible Envelope Load: 21664 Btuh Duct load (DGM of 0.017) 375 Btuh Sensible Load All Zones 22038 Btuh EnergyGauge® FLRCPB v4.5 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) RELIANCE HEATING &AIR Project Title: Code Only 1800 - Perrillo Homesite Professional Version Climate: Central 3/19/2007 WHOLE HOUSE TOTALS Sensible Envelope Load All Zones 21664 Btuh Sensible Duct Load 375 Btuh Total Sensible Zone Loads 22038 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 22038 Btuh Totals for Cooling Latent infiltration gain (for 56 gr. humidity difference) 2146 Btuh Latent ventilation gain 0 Btuh Latent duct gain 243 Btuh Latent occupant gain (4 people @ 200 Btuh per person) 800 Btuh Latent other gain 600 Btuh Latent total gain 3790 Btuh TOTAL GAIN 25828 Btuh EQUIPMENT .,_.`. �.ti..�«. :a.„o .3:.�1,'+.z4+ �.pc¢•., ,9,,.,,, s .____. .>.. ,,,t a� R -3r> .-¢a 1. Central Unit # 40500 Btuh *Key: Window types(Pn-Number of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value or as clear or tint) (U-Window U-Factor or'DEF'for default) (InSh-Interior shading device: none(N), Blinds(B), Draperies(D)or Roller Shades(R)) (ExSh-Exterior shading device:none(N)or numerical value) (BS-Insect screen: none(N), Full(F)or Half(H)) (Ornt-compass orientation) Version 8 For Florida residences only EnergyGauge® FLRCPB v4.5 Page 2 System Sizing Calculations - Summer Residential Load - Room by Room Component Details RELIANCE HEATING &AIR Project Title: Code Only 1800- Perrillo Homesite Professional Version Climate: Central Reference City: Tampa (Defaults) Summer Temperature Difference: 16.0 F 3/19/2007 This calculation is for Worst Case.The house has been rotated 315 degrees. Type* Overhang Window Area(sgft) HTM Load Window Pn/SHGC/U/InSh/ExSh/IS 0rntj Len Hgt Gross Shaded Unshaded Shaded Unshaded — 1 4.5 4.5 0.0 25 50 113 Btuh 1,Clear, 1.27,B-M, N,H SE 5ft. 2ft. j 2 1,Clear, 1.27, B-M, N,H SE 5ft. 8ft. 8.5 8.5 0.0 25 50 214 Btuh 3 1,Clear, 1.27, B-M,N,H SE 1ft. Oft. 19.5 19.5 0.0 25 50 492 Btuh 4 1,Clear, 1.27, B-M, N,H SW 1ft. Oft. 5.3 5.3 0.0 25 50 135 Btuh 5 1,Clear, 1.27, B-M, N,H SW Oft. Oft. 14.3 0.0 14.3 25 50 715 Btuh 6 1, Clear, 1.27, B-M, N,H NW 6ft. 26ft. 14.3 0.0 14.3 25 48 683 Btuh 7 1,Clear, 1.27, B-M, N,H NW 6ft. 26ft. 72.0 0.0 72.0 25 48 3432 Btuh 8 1,Clear, 1.27, B-M, N,H NW Oft. Oft. 14.3 0.0 14.3 25 48 683 Btuh 9 1,Clear, 1.27, B-M,N,H NE Oft. Oft. 5.3 0.0 5.3 25 48 254 Btuh 10 1,Clear, 1.27, B-M, N,H NE 1ft. Oft. 10.8 0.0 10.8 25 48 512 Btuh 1! Walls Type R-Value/U-Value (sqft) 7234 Btuh Window Total yp -Value Area(sqft) HTM Load 1 Concrete Blk,Hollow-Ext 4.2/0.14 1660.0 2.3 3882 Btuh 2 Frame-Wood-Adj 11.0/0.09 160.0 1.5 243 Btuh Wall Total 1820 (sqft) 4125 Btuh Doors Type Area (sqft) HTM Load 1 Wood-Adjacent 17.7 14.6 258 Btuh 2 Insulated-Exterior 30.2 9.4 1 285 Btuh Door Total 48 (sqft) 544 Btuh 9 Type/Color/Surface - - Ceilings T e/Color/Surface R-Value Area(sqft) HTM Load 1 Vented Attic/Light/Tile 19.0 1800.0 1.3 1 2294 Btuh Ceiling Total 1800 (sqft)_ - 2294 Btuh Floors Type . R-Value Size HTM Load 1 Slab On Grade 0.0 182(ft(p)) 0.0 0 Btuh Floor Total 182.0 (sqft) 0 Btuh Zone Envelope Subtotal: 14196 Btuh Infiltration Type ACH Volume(cuft)wall area(sqft) CFM= Load SensibleNatural 0.20 16920 1820 56.4 992 Btuh P Btuh/occupant PP Internal Occupants Appliance Load gain 4 X 230 + 5555 6475 Btuh Sensible Envelope Load: 21664 Btuh Duct load Average sealed, Supply(R6.0-Attic), Return(R6.0-Attic) (DGM of 0.017) 375 Btuh Sensible Zone Load 22038 Btuh EnergyGauge® FLRCPB v4.5 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) RELIANCE HEATING &AIR Project Title: Code Only 1800 - Perrillo Homesite Professional Version Climate: Central WHOAWHOLE HOUSE TOTALSa i i ftE � 56E�' rrI E€tG€ aa Sensible Envelope Load All Zones 21664 Btuh Sensible Duct Load 375 Btuh Total Sensible Zone Loads 22038 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 22038 Btuh Totals for Cooling Latent infiltration gain (for 56 gr. humidity difference) 2146 Btuh Latent ventilation gain 0 Btuh Latent duct gain 243 Btuh Latent occupant gain (4 people @ 200 Btuh per person) 800 Btuh Latent other gain 600 Btuh Latent total gain 3790 Btuh TOTAL GAIN 25828 Btuh EQUIPMENT E 1. Central Unit # 40500 Btuh *Key: Window types(Pn-Number of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value or as clear or tint) (U-Window U-Factor or'DEF'for default) (InSh-Interior shading device: none(N),Blinds(B), Draperies(D)or Roller Shades(R)) (ExSh-Exterior shading device: none(N)or numerical value) (BS-Insect screen: none(N), Full(F)or Half(H)) (Ornt-compass orientation) Version 8 For Florida residences only EnergyGauge® FLRCPB v4.5 Page 2 Residential Window Diversity MidSummer RELIANCE HEATING &AIR Project Title: Code Only 1800- Perrillo Homesite Professional Version Climate: Central 3/19/2007 .,.:...Weather Summer design temperature 91 F Average window load for July 7511 Btuh Summer setpoint 75 F Peak window load for July 12461 Btu Summer temperature difference 16 F Excusion limit(130% of Ave.) 9765 Btuh Latitude 28 North Window excursion Jul 2696 Btuh WINDOW Average and Peak Loads 10000 00 Limit for excursion 90)0 0'; 800000 12 Hour Average 7000 00 600000 600000 4000 00 3000 00 2000 00 ',0<00 000 arm:• 10 12 2pm 4'p.. 5prn 8pn-m a n Total July Window Load(Radiation and conduction) This application has glass areas that produce large heat gains for part of the day. Variable air volume devices are required to overcome spikes in solar gain for one or more rooms. Install a zoned system or provide zone control for problem rooms. Single speed equipment may not be suitable for the application. EnergyGauge®System Sizing for Floridnces only PREPARED BY: DATE: — EnergyGauge® FLRCPB v4.5 (5'jI 8d32ild :uo!saan)®a6neoit6ieu3 'q'gZ se6ed uo Indlno sseIE)Jalu!M' iawwng aas seam pue edAI ssel6 lenloe jod -adAI sselb)ueuiwopaJd ? :31va :31da :1VIoIddO JNIa11l8 �1N3JV23NMO •salnle1S ep!Jold 8p03 A6Jau3 epuold aqI 111!M 806t99 uo!Ioas IBM eoue!ldwoo eoue!ldwoo u!S! peu6!sep se'6uipl!nq sigI Iegl A4flJao Ageiaq I ioo paloadsu!aq II!M 6u!pl!nq s!gI A Iki palaldwoo s! uo!IonJIsuoo eJo;a8 �31Ha •apo3 A6Jau3 epuold aL1 II!nn :A8 a32IVd3Md eoue!ldwoo seleo!pui uo!Ielnoleo •apo0 ����ts a8y3o s!ql Aq peienoo suo!Ieoq!oads A6Jeu3 epuold agB IB!nn aoue!ldwoo u!aie uo!Ielnoleo s!qf pue sueld aqI}o Ma!na�l Aq paienoo suo!Ieog!oads pue sueld aqI Iegl A4!lJeo Agalaq I SSVd b9t-5Z :sluiod aseq ielol - - C60£Z :sluiod lllnq-se lelol 600 :easy aool.j/sselO (8utleaq V/N 'q `Buil000 8 0'SL`0'9=-d.dnS aoua)ul:HV •oufl:Ia)I •oufl:dnS •e `Ielsouuoq j a[geunueadojd-1 d slonU 'El `uej asnoq log-in V/N o `uoge[!IuaA ssoia-A3`uuJ Bug!aO-3J) V/N q Id s)p '°JVAH 'Si zu 00081 `0'61=)I o!llV.iapuf •e (dwnd)eaq poleo!PaQ-dHQ sad,il 0ug!a) -01 JUJOS`,t.IaA0 IsaH-21H) V/N 'a s)!pOJo uo!leA.iasuoJ •o V/N P V/N 'o v/N'q Zu 0091 '01I=1 Iuaoefpd`pooh`awei3 •q Z6'0:dg Z1I 00991 `Z'b=)I loualxg'Insul lxg`ala.iouoD •e suolluO 0.0j:dej aouels!sag ouloalg •e sad,C1 lleM 6 swals,ts.ia)5M IoH 171 V/N o V/N 'q II(d)0'Z81 `0'0=)I uou tnsul a2pg ape.z9-uo-gelS •e sad,Cl aoold 8 V/N q dl 6891 ( ID) qL (.L1fnvggu Iu!Z ao ao) 0I'8:ddSH :OJHS 'q aq/nl pi S'Zb:dui dwnd Ieall o!.�loa[g •e — dl 6891 (llnejaG D1 uS)eL (.LifldggQ algnoQ io aldu!S Jo) swals,Cs 3utleaH '£l eDJ ' uollduosaCI :ao)o3-fl e (11nujap louJ1 S'tb'b01-£[(q•pbaa lagewl):sate pue Iad,CI sse[O L V/N 'a Z1J 0081 (Zg)Sate.ioou pauot)!puo,) •9 saA /,aseo stom e sup sI -S V/N q b swootpog Jo.iaquznN •17 00'£[ :)IggS [ (I!we3-!)lnw3!`sl!un jo.iaqu mN '£ 1Wnl S'0b:dsD l!ufl le.11uai •e — ,CI!ure3 al8u!S ,C[!we3-!Ilnw JO,CI!we3 aldu!S •Z swals,Cs 3u!looj •Z I — MDN du!Is!xa to uo!)onilsuoo MDN I lejlueo :auoZ ejew!Io :JagwnN uol;o!psunr tIV'8 JNIIV3H 33NVI132I :Jeumo :JagwnN;!wJad :a}els `fl!o :a0!-4O 6u!p!waad :sseippy ollliJad :Japl!nl3 a;lsawOH Oil!JJad- 0086 :eweN poafad V poq ej aouewJOjJed 6u!plin8 aIot4M IeiRuapisa� sne}}y/(liunwwoo }o luawpedaa epuold NOI13fl?J1SNOa ONIa1If19 ?JOI 3aoo A3N31aEI AOH3N3 baI?JO1I g j ®e6neOA6Jeu3 2iV00Z-b'009 WbOJ 11111111111111111111111111111111 111ff IIIII IIIII IIIII IIII IIII 2007150165 Rcpt: 1126824 Ree: 10.00 DS: 0.00 IT: 0.00 09/05/07 Dpty Clerk JED PITTMAN, PASCO COUNTY CLERK 0OR0BK 7623m PG A10 NOTICE OF COMMENCEMENT Permit No. Property Identification No. - \-n Ol(� - Lb00-p pq p THE UNDERSIGNED hereby give informs you that the improvement will be made to certain real property,and in accordance with Section 713.13 of the Florida Statutes,the following information is provided in this NOTICE OF COMMENCEMENT. 1.Description of property(legal description:) `_b4- yp _.[ a)Street Address: 2.General description of improvements: 3.Owner Information a)Name and address: ' ' ' b)Name and address of fee simple titleholder(if o'ther than owner) c)Interest in property p iQ( 4.Contractor Information a)Name and address: P ' a ', c sça11. 3Sc(y b)Telephone No.: Pa1!30-1-110L Fax No.(Opt.) 5.Surety Information a)Name and address: b)Amount of Bond: c)Telephone No.: Fax No.(Opt.) 6.Lender a)Name and address: Phone No. 7.Identity of person within the State of Florida designated by owner upon whom notices or other documents may be served: a)Name and address: P �qa x AS k Skcl o L.1. ls)ek (tom ` _C'I . . b)Telephone No.: 8t' -7Lr,—gOM2 'Fax No. (Opt.) 8.In addition to himself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.13(l)(b),Florida Statutes: a)Name and address: b)Telephone No.: Fax No.(Opt.) 9.Expiration date of Notice of Commencement(the expiration date is one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART I,SECTION 713.13, FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PASCO P % DIANN KLIMpEL r MY COMMISSION N DDS73400 S' er or Owner's Authorized Officer/Director/Partner/Manager EXPIRES;July 12,2010 Id1M►3-WTARV FI.Notary 136MM A. .Ca nt Name The foregoing instrument was acknowledged before me this 6 clay of S ,(7 F ,,20Q,by as (type of authority,e.g.officer,trustee,attorney in fact)for (name of party on behalf of whom instrument was executed). Personally Known OR Produced Identification L—' Notary Signature Type of Identification Produced -.__._-- Name(print) (p_ )( / vi-..p _ Verification pursuant to Section 92.525,Florida Statutes.Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. Signature of Natural Person Signing Above FORMS/NOC,rvsd2007 STATE OF FLORIDA-'/ COUNTY OF PASG THIS IS TO CERTIFYNA`T T 4E FOREGQING IS A TIiUE AND CORRECT COPY 1#THE DOCUMENTT ON FILE dR OF PUBLIC RECORD IN T iIS,OFFICE, ITNESSw HAND AN OFFICIAL EAL TVi1S DAY OF, '' JEtI CLERK OF CIRCUIT COURT BY DEPUTY CLERK ty 1 u f.5G t ♦'yi/tL iir�ti'l; f 3 d a1a y 7r i } y ` �_ ✓.mss.-� �' l.. '-�['--,.' �` Y ffi • • w �a"j 'Y'`_ti r�r�>;�+�� �4�-'� d�• �r �-Cw ,r�Tl�'Sri' �7.�r �Y�4,1.`yr.,. 'J�.:�y�[�*�r�r�µ'j,- �.�,�:• _•+mod,• � ia. I { . �•,,, .try t7'4 TCJ� (t "l 4 � '_,�. � � ♦ Saw ' ' ,T!'f' f, : , I.'�."._s'.._t", 09/12/2007 09:48 8138898082 VARA PAGE 05/07 � �- CERTIFICATE OF LIABILITY INSURANCE D9/12/2OO7 PRODUCER THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION A SILSR M INSURANCE INC ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR 1401 W. Busch Boulevard ALTER THE COVERAGE MFORDCD BY THE POLICIES BELOW_ Tampa, FL 33612 (813)931-7467 Phone / (813)932-7336 Fax INSURERS AFFORDING COVERAGE NAIC# WBURLro INSURER A: North Poitlte Insurance Company Vara Electric Corp. INSURER I;: First CONWrCial Tesuranro Cmrpaty 6135 Larishire Drive INSURER C: Tampa, FL 33634 INSURER D: I INSURER E: COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED.NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN iS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.AGGREGATE LIAIfTS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. -L POLICY NUMBERDATE POLICY EFFDE TIVE POLICY LIMITS GENERAL LIABILITY EACH OCCURRENCE 31.000 0 X COMUERCIAI.GENER�AL-U�ADIUTY PR $ 100 OQ CLAIMS MADE L-L..J OCCUR MED EXP(Any crle pe's i 5 Q A 8090003555 06/18/07 06/18/08 PER SONALaADVINJURY $ 1,000,000 GENERAL AGGREGATE $ 2.000.000 GEN'L AGGREGATE Limit APPLIES P2�R: PRODUCTS-COMPlOPROB $ Z 000 000 POLICY fl fl LOC AUTOMOBILE LIABILITY ANYAUTO �0 >eccdentj ED SINGLE LIMIT $ ALL OWNED AUTOS DODdYtNJURY S SCHEDULED AUTOS (Pw ParQrr) HIRED AUTOS BODILY INJURY NON-OWNEDAUTOS (Perapddenl) i PROPERTY DAMAGE (Perecclaen!) GARAGE LIABILITY AUTO ONLY.EA ACCIDENT $ _ ANYAUTO THAN EAACC I OTHER AVTOONLr. ACC $ EXCESS/UMBRELLA UAZLTY EACH OCCURRENCE $ OCCUR u CLAIMS MADE AGGREGATE jjj DEDUCTIBLE $ RETENTION S $ WC WORRXRSCOMPENSATIQNAND X ORY MR 07H ER _ EMPL,OYERE UABNJTY ANY PROPRIEIDPoPARr EREXECUTIVE E.L.EACH ACCIDENT $ 100.000 B OPFIGERINE C LODW ? 07-219268 08/27/07 06/27/08 E.Lou SEASE-EAEMPL 100,000 S IALPROVISIONSbelow E.L.DISEASE-POLICYLiMT 1 500 000 OTHER ]ESCRIPTIOM OF OPERATIONS 1 LOCATIONS I VEHICLES!EXCLUSIONS ADDED BY ENDORSEMENT!SPECIAL PROVISIONS Electric work IERT1FICATEE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION City of Zephyrhills DATE THEREOF.THE ISSUING INSURER WILL ENDEAVOR TO MAIL 10 DAYS WRITT1;N Contxaetor Certificate 5335 8th S tx*ot NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT.BUT FAILURE TO DO SO SHALL Zephythllls, FL 33542 IMPOSE NO OBLIGATION ORABILITY OF ANY KIND U The IN$UrpER,ITS AGENTS OR REPRESEA(TATWEB. AUTHORIZED REPRESE 1CORD 23(2001108) SI ACORD CORPORATION 1988 p �`3 ^{,^• rl�l i��i��F *4 x^d4�'��F'�t .M. 1 M t'itia i �FY �mf � , � ` � '• +�S � w°�aa4.1�*' u^".ei IM r, 'r '' ;�p a *'Yk rta.. Pt ,* � 'C t f uk 4 mI 'e., • ! a �d y . •yir x y of' 4 t. ' ', bti 5 r ! 4' y4 1� .s a rr�• *r� t�'�+nyA �P yr'�1�'rr Y�i# 1 �vgrtif IF{v$s k y' 1� R t o.• r�tv t�It.;.iaxi'�?�•� ��re��4�°� r�,�tl��N. d.,•�d n t 6 :t �, t r ��`Ik W ♦4♦ * "'Y d,�a fn:b.Y+t �(lr� tr3 tr« 1�.j SS a is r. +, �'V. •4 fSv " ,� .,* #`'Au * 7. ,� �. i w'Y�nnr'�k++�.'o.Ff--{.�it"s $1•.." +gyt`i!P�';'�1) \' ,wi.a +t F — 1�T1 t- '� •, > Jt ;txta ~• a4 ' 2 * �s Y Y.S �iwtt"1 Yi'� r L 44 - � � m '� �► % �''Yj I �•. � 'r r iyr� tot fl c �, ! srh t4 rrF a wa 44 +x 4 _tcr't a +f .jC . •rte , .F 1 , . atIr 4w'1 • '�p„ ' 44 t J y�fr'A•'' W ' �. T S 4 - , } �y s s i Mf • ` 44 � 3 1 VV t rn. {Qs g Ada V V p •✓VU a kV u. , J VV , v VV VV ' � � t r ) a�•ft' y, J ' VV �r s jr 4V VVVVV VV' VV V Y ty A. •qtr.• ,,.��E` 07-03-2007 ALEX SINK STATE OF FLORIDA CHIEF FINANCIAL OFFICER DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION * * CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS' COMPENSATION LAW CONSTRUCTION INDUSTRY EXEMPTION This certifies that the individual listed below has elected to be exempt from Florida Workers' Compensation law. EFFECTIVE DATE: 07/03/2007 EXPIRATION DATE: 07/02/2009 PERSON: PERILLO RANDY T FEIN: 202460382 BUSINESS NAME AND ADDRESS: PERILLO & ASSOCIATES LLC 5501 RIVA RIDGE DRIVE WESLEY CHAPEL FL 33544 SCOPES OF BUSINESS OR TRADE: 1- CERTIFIED GENERAL CONTRACTOR IMPORTANT: Pursuant to Chapter 440 . 05(14), F.S., an officer of a corporation who elects exemption from this chapter by filing a certificate of election under this section may not recover benefits or compensation under this chapter. Pursuant to Chapter 440.051121, F.S., Certificates of election to be exempt... apply only within the scope of the business or trade listed an the notice of election to be exempt. Pursuant to Chapter 440.05(13), F.S., Notices of election to be exempt and certificates of election to be exempt shall be subject to revocation if, at any time after the filing of the notice or the issuance of the certificate, the person named on the notice or certificate no longer meets the requirements of this section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the person named on the certificate to meet the requirements of this section. QUESTIONS? (850) 413-1609 OWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 09-06 PLEASE CUT OUT THE CARD BELOW AND RETAIN FOR FUTURE REFERENCE STATE OF FLORIDA IMPORTANT DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS'COMPENSATION F Pursuant to Chapter 440.05(14), F.S., an officer of a corporation who CONSTRUCTION INDUSTRY O elects exemption from this chapter by filing a certificate of election CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA - L under this Section may not recover benefits or compensation under this WORKERS'COMPENSATION LAW "• "� D chapter. EFFECTIVE: 07/03/2007 EXPIRATION DATE: 07/02/2009 H Pursuant to Chapter 440.05(12), F.S., Certificates of election to be PERSON: RANDY T PERILLO exempt.. apply only within the scope of the business or trade listed on FEIN: 202460382 E the notice of election to be exempt. BUSINESS NAME AND ADDRESS: E Pursuant to Chapter 440.05(13), F.S., Notices of election to be exempt PERILLO & ASSOCIATES LLC and certificates of election to be exempt shall be subject to revocation 5501 RIVA RIDGE DRIVE if, at any time after the filing of the notice or the issuance of the WESLEY CHAPEL, FL 33544 certificate, the person named on the notice or certificate no longer meets the requirements of this section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the SCOPE OF BUSINESS OR TRADE: person named on the certificate to meet the requirements of this 1- CERTIFIED GENERAL CONTRACTOR section. QUESTIONS? (850) 413-1609 CUT HERE * Carry bottom portion on the job, keep upper portion for your records. DWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 09-06 _ SEP. 7. 2007_10: 12AM -A. KLBRIDE NO. 298P. 1D,YYYY) AGQRDw CERTIFICATE OF LIABILITY INSURANCE i nooi PRODUCER THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE 1401 W. Busch Boulevard ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW A. ICilbride Insurance, Inc. HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR Tampa, FL 33612 INSURERS AFFORDING COVERAGE NAIL# 813,931,7467 Phone/8X3.932.7336 Fax NSURER A; ld1d..Contirlent Casualty Company INSURED I Penile & ASSOCiat$s LLC INSURERS 14aosriaa> Staten In5urEnee ConpanY 5501 Riva Ridge Drive INSURER C: Wesley Chapel, FL 33544 INSURER D: INSURER E: COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED,NOTWITHSTANDING S ANY REQUIREMENT.TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS.EXCLUSIONS AND CONEITIONS OF SUCH POLICIES.AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED 9Y PAID CLAIMS. POLICY EFFECTNE POL LMITs R POLICY NUMBER DA EACH OCCURRENCE S 1 000 GENERAL LIABILITY S 100 OO PREMIS S Ea owirerroe COMMERCIALOENERALLIABILMY MEOEXP(Anyanopereen) s BJs;00. CLUD CWMSMADE Ez OCCUR PERSONAL6AOVINJURY S 1 .000.000 A 04GL000685844 O8/22/O7 08/22/08 GENERAL AGGREGATE s 2 000 000 aontraetural liability PRODUCTS-COMPIOPAGs S 2 000 000 GEN'L AGGREGATE LIMIT APPLIEri;iS PER' x POLICY S JE LOC pUTOMOBILELIABILITY COMBMED SINGLE LIMIT S �.,OOO OOO (Ea accldenll ANYAUTO BODILY INJURY ][ ALL OWNED AUTOS $ LED (Pc.person) SCHEDU AUTOS B SCEDLED 01CH3976211 01/17/07 01/17/08 BOPILYINJURY s (peraWdsr%) X NON-OWNED AUTOS PROPERTY OANMOE (DraccicI I) AUTO ONLYEAACCIDENT $ GARAGE LIABILITY EA GC S OTHER THAN ANYAIITO AUTO ONLY: AGG $ EACH OCCURRENCE i EXCESSIUMBRELLA LIABUTY AGGREGATE $ OCCUR CLAIMStpAPE $ S DE000nELE i RETENTION S WC ATU. OTT+ T TT WORKERSCOMPENSATIONAND E.1-.EACH ACCIDENT S EMPLOYERS'LIABILITY OPPICEREMS AWv r?40nwr RIPNiTN9PA0=UTNE EL.DISEASE-EA EMPUOVE $ flyeu d99P O6undef EL.DISEASE•POLICY.$MIT i SPECIAL PROVISIONS babes OTHER DESCRIPTION OF OPERATIONS!LOCATIONSI VEHICLES I EXCLUSIONS ADDED BY ENDORS EMENT J SPECIAL PROVISIONS Certified General Contractor/Homebuilder CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE TIiEREOF.THE ISSUING INSURER WILL ENDEAVOR TO MAIL 10 DAYS WWTTEN City of Zepherhills 5335 Sill Street NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT,BUT FAILURE TO DO SO SHALL IMPOSE NO OBLIGATION OR LIABILI Y OF ANY KIND UPON THE INSURER ITS AGENTS OR Zepherhil].s, EL 33542 REPRESENTATIVES Pax(813)433-2464 AUTHORIZEDREPRESE T ....( RD CORPORATIO 988 ACORD 25(2001108) P . 01 /01 TRANSACTION REPORT SEP/07/2007/FRI 02 : 28 PM FAX (TX) # DATE START T. RECEIVER COM.TIME PAGE TYPE/NOTE FILE 01 SEP/07 02: 27PM PASCO ADDRESSING 0:00:38 2 OK SG3 5289 e ' - :ICY +uCl'M1f y :....................... . u. .... ....... City of.Z.ephy 'hills — Building Dept Phone: (813)-78.0-0020• FAX: (813)-780-0021 Date: 9-7-07 TO: Judy/Gail FROM: Kj&ren- kmilleracizephyrhills.fl.us FAX#: 727-815-7000 • #PAGES: 2 • • MESSAGE: Hope your day is going GREAT. We have a project which we need an • address for. Listed below is the information concerning it. If you have any questions, • please contact me. Thank you. Parcel: 11-26-21 X001041600-0090 Type: • • • X Residential 0 7Commercial ❑ Other • Lot Number: 9 • • Street Facing: 13 . Street z a ��+ ri H: H EA P4 :..H G bm H oa _ O wvi O . O , H c� M UH Q 14 1 .0 140 . Go a N m H g ro9aa9 OH ao 0 aAc�7 E+ m oa z 0 a U a �HWOWH p; Ln O vqA WUa m�HH Oa o�•q ®cn a UA EEop'53 uU m. •°A OWE aA��rtHP4 264 wa4 mm• SID + t110 g •d Q6S =60 SO EZ °aU Dec 23 05 O9: 59a p22 . � 0 w pJ z ' q 0ci) v Cl) a k k w ' *'x 'HI �� w2§ &Q u& 1) S w \�� �� $ nk 24 k ALL w 2 §f �� �.. . . TT \. . . . . . . ■ / . KW _ . cc \ O r u NCO �o | L Q . QZW 0 S Ow E III } q 5w \ / 09/22/2006 22:29 8138898882 Vim'' 02-25-2005 3M GALLAcR nwwaAl OFFICER D1VIS ON OF WOORKERS COMPENSATION •CERTIFICATE OF EXEMPTION FROM FLORIDA WORKERS'COMPENSATION LAW ONSTRUCTION INDUSTRY EXEMPTION his certifies that the individual fisted below has elected to be exe iorids Workers' Compensation Law.. UOUTRE FFECTIVE DATE 02/25/2005 **EXP A 007 T ERSON: VARA I a CTRIC CORP 613 5 LANSHIRE DR TAMPA FL 33634 CRQBUSINESS 1 - ELECTRICAL CONTRACTOR PORTANT: Pursuant to Chapter 440 . 05(14). P.S. an officer of a corporation who elects cemotlon from this chapter by fi�ielB a certificate of election under this section may not recover its or compensation under this chapter. $Z cernRCATE OF aECT)0N TO BE EXEWr FAMED c 1-os OIlES110S? (8101413-1601 PLEASE CUT OUT THE CARO BELOW AND RETAIN FOR FUTURE REFERENCE itv°rop ss°FATi t� F TNJc110N J USTRY O ' T i Av R"WA D IMPORTANT rnE 0212512006 , fAMIATXX DATE 02/2512007 H FwWw to Chapter 444.46(14, F.$,, a officer of e sr: VARA NTS E capaedoe who uses exNeptaa from ill chapter by fling 73 R e certif ute of ekcden under the eectioa may cot recover E benefit: or coapenution under this chapter. Fl 33634 OF f+sU6 LSS OR TRADE :TFtICAL CONTRACTOR DLISIDIS7 (950) 413.1609 CUT HERE • Carry bottom portion on the job, keep upper portion for your records. t CSITWCATE OF MECTION To BE E)C .WT REVIBFp 01-04 89/22/2006 22:29 8138898082 VARA r.. OLFU+ STATE OF FLORIDA DEPART T OE BUSINE98 AND PROFESSIONAL REGULATION ELECTRICAL CONTRACTORS LICEN$xNG BOARD (850) 487-1395 1940 NORTH MONROE STREET TALLABASSEE FL 32399-0783 YARA. ROI+ANDO ' vARA ELECTRIC CORP T6135 �eSIRS DR A FL 33634 yy, , Y.ppt ' wry a• I x�, • .�f.►w •ta pit = �, i q DETACH HERE m I•,�r�•':� ,' �f t.:�;5-S7o:'L r<' '? �' '� �'i;:':�kdsii �'r[;'�y�-+�' :t�j `+' fy A4y(,�(ra. a µ.�1,�•k•�j��, rt• '1'..�• / ji•. li.1�'.t•r,•••' y riy'I r\'.�Cj �' r•1r't.: � j �1.."•, 74T.Y},/'y 71 S"'�t ;•� ' .t' ;'4/•,;s' 1�%7, 1, r; tf t t. yfJ•,A,� y7,• ji.;:' -i ?y'�'ti�r,�'q tlY,t'.iii' t Yt` 1-• 7,�r, 9•••s',�}' '•�•+tY', + .y,•• 1 f`H .,a n•.'"'tJ•.+�.�/. i<r r j;?; r �t ! .:l.,tf*'+r '; i:• a 7 �•Js`�. � �3•+. '�� ..kctirlr, r,.,,+ttt :1,'ri.i. 'rs'.• �' Y r.. Jr. 7 M.,..u�:i•,+ J*Hr '�•. � '.•lyjt,�!y:•; .• •xtiycS"�3sr+-•' • \ `11ft Y' J+(i t .7 .� ,�;}.. tire_ L• ..., '••s�� ,t •i M•`r�•t't,;; 'v, t'..:?:,1y�p:.t� '• .tg#•,r F!'r :t ..�,:•.��yv. ..A yrr' •1 ..:. Sh. i•1 ' �• < r4 .:,. 'j','••'� 7, iz:t' sly• '}r. V r v n .... .i.C .` .. .�ti !. :1�::::t yY'"' ''�'�•s ryY,.t :Ste '�::fjiis�f'�1�s•j�1{*!,�i1Jt•. �. qJ 'r•' \•�j,�� � .1' �l'�: . wr..^.Rt .�yy� t ,;r �c"y' • 1 -:.t `• �+:•- •tY•'`^lLr.r,'...,^��X.�e::l�� �;, e.7 f�'t. ,+�Lrs '.jt r,:1 "�... Yii�s�lf��7{1(I�•,t .: r : — j� ' ,,jj aw :•.rjl�,�'S R' rJrr ;..�L..• r+'ti.'r'� �� tom. r 'i '�:, 'i:.. �I{ ,�}j�`• ' .. . ' tr.• I . rj:••: :'• .a. •.a�- r{r ti 1,t„• .t...• 1r. 1 i s:*•. jp .t'N• '• :�•�'":\ ,,•'� y�. .ti t.; � f• t k.t,i, Fi`•t•:•{t Y"jt'•.� �Lq�f a�;Z1:•,C�''b,;,l,.+'•,n: '�• cL, ! , •T�"`' Y : �'7\ �.�t1_ ,+� �l 'Vs;iyra•,..�.i.�a•`�+�:�'r•.?'t,: , ff �ie. rl• a f'� '!.'.,�yh i. .•R1"'�;+,�Zk' '�'�'��1-„t�'Ts�x !i;.: yr ��• art'• � +�, �tl* .x+4t, +•' y ' j� ti �Yf1 r.Ji. :.1d� mot! •T:��'J�;�, r.t•.•.,�,. •3'� �• IJf.�i • •�r�, ��.r ,�. i '.�I '�;.. :���! t.'�y� r '�L F li r" •`G• :;•i',L ::�., v � ,.y[�'t A � _t .j . , .•,••\y.S':� t:::4)7�•7�F%I i�t ��- � ,� 4K.,:•rYJr.''4• •N!'t�•r. y} t S j 1. 1...tS.r.. ta... r{ •::„ 1�7•"t•J'rt•y i�'.:�r .FYI' is „�.•rl1 '�!�` � �••-at�'�'�. 1`.,;,::.ice ^.N..K.ri. Y't �` t'- M�: ; .r' �.!,. ;•�. '1' ,s „l`,•,�:,.:,:.''1' ,�7)s"��7 -N'.• `�j - ,'pi,''G•rwR'.li.',.;'r..,.:��• n f.. •�•y t'•'•,}�•�p.•" � �Y.,, •.,�w JAS. ,,•r �.. :'.'`•• �: r {•'��VI••. t.7Y 1, 57• ;,yh'• _.i` rJ�,{ai.i.•.^:rr..yyy/'�ir,✓Lti' ht1 .* i �.i•' .41 i.it .."t�,r�'tt'��.r,: �. � r.1{i` j d J'r.;- thS�!,:�i,,'•i�a:r ' ,�. ��. ',}.. ;r., 'i., •=8' .,r.a�J .'.� Pub. .s •'}?if,F�j�S�}Y';:.'✓--jj♦. r.r„• ,.. ljyyj��••.. !• •• •'r..� .•.,..• •:: F,`a• ;✓;r� +t�:.r;t.ti'.'•�w��•�. •: p \li;.t,�..a.l .7'. •R.f !Sr' 'In'?� { Y( •ti ';' r •;;, '•s:�; :'!; J. y'JY• •''' \r� ''L 'XCI4'. °,ditrK..;.'rr�' ! L.{:rN ;:A' •�Q I jPa�•,"Yft` r. ' `a r. ::fl� tJ.y rte J�. f.. -�e• :{� '\s, �• ii ,^�';:� JC�"fy,. .� r•^-\ w .�. J;CI ,J .`; ,. •a�'..;�.yt,�•,'}:�.�'�'y. r•.:Vie,:.,�,�r.:' r: ..1�•Kt�i.r 1.\a �•�f�•� 1 •� "' jl,,y. :�.f.'': n.,.r '.rte,' 1r 5.•. .C' � •'•� . ... avJ:i�Y17Lli';.y .y: ..y:: ri:.{+'.• ':Ws''.,•ti7;:\; ( + f T'r• "F�':'7 '•••'•,�'i.:Lrrr ..^.�4. 7f s y r • a,}:•'.r. i. �.r.,� �.r. � •.. s4' i.. •.r.t.,'pf f's�ra� .5,',,• :t. - ';r ...t'�, ,O�'.. '•' .',�',r •... .•./.i:, '1 �' .. 3:1;.. :�'{.! l•i!^��.' "'.'.. ...... t:•7.3. .r.4 �G.`��ypr�� � _...:•' ...,-.�. '.�1tK�1'18%:-9•.i.ii�.lrt\ '.4t"iL: .:1. L..�•.3� •a:s;.^.'..: •l�sj='•: ACORD., CERTIFICATE OF LIABILITY INSURANCE p DC 09-05-2006 PAODuc R THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION NORTHEAST 1�GENCfES INC/PHS -FLO ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. 210204 P: (866)467-8730 F: (800)308-5459 ALTERT E H COVERAGE AFFORDED BY THE POLICIESBEOW. 4401 MIDDLE SETTLEMENT RD NEW HARTFORD NY 13 413 INSURERS AFFORDING COVERAGE Iw o INSURSI A:Hartford Casualty Ins Co INSUR61B: ROLANDO VARA & VARA ELECTRIC CORP INSURERC: 6135 LANSHIRE DR. INSURERD: TAMPA FL 3 4 INSURER E: COVERAGES THE POLICIES Of INSURANCE USTED BELOW HAVE U NAMED L INDICATED.NOTWffHSTAN I ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. lAf6R TYPr≤OF/A6LIL4M7E POLICY A/MBL!P PLLILYEfL1<Cr/VE PIDILCr EXPIRA TA71Y n. LMIITS LiSVERAL LMAWY EACH OCCURRENCE s l 000, 000 A coMMERCIAL wmwAL u*BIUTY 01 SBM AP 0543 5 4 3 03/07/06 03/07/07 FIRE DAMAGE(An .n.No) s300,000 CWMS MADE [ j OCCUR MB)EXP(Mw on. son) 110 000 X Business Liab PERSONALAADVINJURY $1,000, 000 GENERAL AGGREGATE s2,000,000 GEN'L AOG EGATE LIMIT APPLIES PER: PRODUCTS-COMPIOP AGO s 2 000, 000 PoucY X �1OT1LOC ALIT NOW LNBLJTY COMBINED SINGLE UMIT ANY AUTO (Em i°@ld.nS ALL OWNED AUTOS BODILY INJURY SCHEDULED AUTOS ( (poison) $ ( (poison) HIRED AUTOS BODILY INJURY NON-OWNED AUTOS (PM.00idut) $ PROPERTY DAMAGE (Pw AooidnS) SAMGE LMSBfV AUTO ONLY-EA ACCIDENT $ ANY AUTO OTHER THAN EA ACC 4 AUTO ONLY: AGO I E>CESSLM8WT' EACH OCCURRENCE $ OCCUR CLAIMS MADE AGGREGATE $ DEDUCTIBLE $ RETENTION $ $ VIONXIMS COAVIEN&AAONAAO WC STAN- OTH- EMPWYMS LIABIPrY E.L.EACH ACCIDENT $ E.L.DISEASE-EA EMPLOYEE $ EL DISEASE-POLICY OMIT $ o7NR DESCRFaONOFOPERAYJVAWAOCAY=AISlwI LES'EXaLSEOMSADDEDBYEADOR NrAWEL7MAl PAOYLS"S Those usual to the Insured' s Operations. CERTIFICATE HOLDER Li Aaa 1 &4L AYSURED D L.ER[ETTEA CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,THE ISSUING INSURER WILL ENDEAVOR TO MAIL 30 DAYS WRITTEN NOTICE(10 DAYS FOR NON-PAYMENT)TO THE CERTIFICATE Parillo Associates HOLDER NAMED TO THE LEFT,BUT FAILURE TO DO SO SHALL IMPOSE NO )BLIGATION OR OOR LI BIUTY OF ANY KIND UPON THE INSURER,ITS AGENTS OR 5501 Riveridge Dr. Gibsonton, FL 33534 AUTD REPAWdT.41,W ACORD 25-S(7/97) °ACORD CORPORATION 1988 f'*4o ct'°> PERFORMANCE BUSINESS PRODUCTS,INC.813-719-8008 FAX 813-719-7919 i f CITY OF ZEPHYRHILLS ZEPHYRHILLS,FLORIDA WATER ACCT.NO._____________________________ DATE_g -O OWNER/ � .�c�� � RENTER G�f i 1�v o l 5Soc (3 is MAILING a-7 g"da 1-i h ca(r, PI a - q SERVICE ADDRESS E3 5 l t'2,-fl 34- 1 WATER SHUT OFF SERVICE ❑ ❑ SEWER TURN ON SERVICE ❑ GARBAGE INSTALL METER i IN CITY READ METER ❑ ❑ OUT CITY CHECK METER ❑ No.OF UNITS OTHER ❑ DEPOSIT AMOUNT q AMOUNT LAST BILL DATE f . l MISC.CHARGE WORK COMPLETED BY ORDER TAKEN BY &DATE COMPLETED ORDER GIVEN BY / 7? 4 ) Retain white form in office at all times. Send pink&yellow forms to Water Service Dept. Water Service Dept to sign yellow form&return to office. J PERMIT APPLICATION DRIVEWAY PERMIT,APPLICATION CONSTRUCTION=WITHIN PUBLIC=RIGHT-OF-WAY ;All information must-be-filled-in completely eCrty.ofZephyrh111S 5335.8th Street,Zephyrhil ls,:FL 33542 Telephone.8.13.780.0000 Fax 813.780.0005 PROJECT JOBSITE: -PROPERTY'OWNER Address: Name: La, Unit: Unit#: Address: 3tC' State 21 D Parcel identification Number: -L6Z phone: ax: ONTRACTOR: Company: U 4 Name: ° E-Mail: + Contractor's License#: ° Fax: Phone: - Cell: =ARCHITECT/ENGINEER: Name: Firm:Name: City: State: Zip: Address: Phone: Cell: Fax: State License#, eeseriotion of Project tO LENGTH OF DRIVEWAY CULVERTS'NEEDED TYPE F DRIVEWAY ti i►WIDTH OF DRIVEWAY ( )REINFORCED CONCRETE RESIDENTIAL DRIVEWAY O WEXCAVATION ( ):CORRUGATED MATERIAL COMMERCIAL DRIVEWAY UN ( )BOX CULVERT PUBLIC ACCESS DRIVEWAYDEFTH ( )OTHER(EXPLAIN) U CONSTRUCTION MATERIAL CRB`CUT REQUIREDYES NO _ OPHALT NCRETE HEADWALL REQUIRED? YES NO NOTICE TO APPLICANT: If actual work exceeds scope of this description,additional permits or drawings will be required. UTILITY LOCATIONS REQUIRED: CALL BEFORE YOU DIG: 1.800.432.4770 HT*Ai, : t►ati rNca# Page.'1 of 3 rtirrAv Irr -- - - PERMIT APPL3CATION OFF.ICEIUSEfONL ( -Concrete (mm . 6") Y N Asphalt Base(min. 6") Y N ' • •r . Asphalt(min.11/2") -Y •N Length (min.Y9') Y N Width (10'min-.20'max) Y N Existing sidewalk. Y N, New sidewalk. Y N ADA compliant. Y N • A- I.JO S (' L Expansion material required. Y N Contiguous parking pad. Y (N ) Triangular flare(3'W x 7'L) Y N Visibility triangle o.k.? Y N Side set back(3'min. R.O.W.) Y N Plan Review Fee • Imo)c r . . TE EPoJbEb 4i CLiJ4 ( - w)c5r M. 7 bE • F2 U C t T NC°_i.aJ S W ` U N� Permit appilcation approved by: • Date: • Page 3 of 3 SCALE: 1" = 30' I I I I I 0' 30' 60' -I >---------------------------------------a I2. I I /i6 li 140' (R) S 64'51'12' W. - 140.03' (M) of 52.0' 68.0' 20.0 — uj I iI LQ.' v'� N PROPOSED RESIDENCE 19.7' 20.0' o / O --------------- ---------- ---- N,(n •I I 46.3' 33.6' J I 140 (R) S. 644940' W. - 140.03' (M) -I_i------ --------------------- ------7 NOTES: Bounary information shown hereon is based on a survey.Boundary Survey by John Walsh, order #W07-0306, dated 3/23/2007. Subject Parcel is Zoned R2-setback requirements are 20'front, 10' side and rear. � ."P�•✓� �'�yI J 4" �q,�, �S... ,k "�[�i y1 '+.r Tc '. yam,;. jam. _. ' l i ✓3r >a .+ }i: r. tf/ {� / n + f K '1 t pY� K � jti t 3 J t + i'0.. I - �++R- t_ N \ Esc.. T f .+."�s .�`^a .'I �,,�• a u � _ .. .,w s J,y�'��! •I ; a.�• +' '+:Ryx '\ate•. +r:r .:+�'nwr i ��i`..•r -..x �r! (ti '�.iF +q;_+ f r i� s -',«-^:.'',e+�.r� !^ s+am'4✓'Y .'' a., I ..• , L`. hsry t ,- -k �a� ,.r aM ^' +c �` 1 stS ✓+sue/ ,e r^ � "� / ; T ' (`p �,r.L'�yy�"}fi'!•�/` �t ��� f'- � t �.i Y' �'• R�Ftt°P5r �� St �. °'• .� {t �P } �,ter'" v �i•+'°:. +�.-}:� _,�+,•_ x •,,� o: „�, ` ^.•--ti',.. ,�rR,a Apr. "S•� "'o-'F`�"' i-y,..l �'S a,. t.,� to + •!'� * "`' "'t'°!►m- +` *. `, .. "., " L ''•� �' `.�' {�-x•„�`�' ;` t `-'�� o� 'fit ^"" �' `�„"' r,,.�- "y ,r a yam, ' t n. �w - off "' YI. "' .*•-'r" ^ "�z'&�c `'" *h w Js t _v fi - t, ` -'.= . }"'•' - -" •t•- �(,1� �., 4 Vii,,,•- ;'. c ` �� ��- •'^f_,,.. �, ;rte� f r .��,...� �',k.-� .� ,,,`• } " .�. _ � yam.- .t. Y� •�,.,w '�rx. ��`'<�dc.,%' *1, €-�.:; - { ! g ,_ -• T 1 + �d i w F pp z ^� tom`,�.•' ..1 '?" r �ja prr - tea, { '- i ` kt ' �>, ; t�.a: f- s, 3� .fry - ou �• �� } j. 1r AI 6 T'4 , ,1: '� e++•'•: by �~ City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Perillo & Assoc. Date Received: 9-7-07 Site: 5541 13th Street Permit Type: Single Family Residence Approved w/no comments:❑ Approved w/the below comments: A Denied w/the below comments: ❑ 1. F.F.E. shall be 8" above road elevation. -- 2. Tie-in survey required before pre-slab inspection. 3. Compaction test required if 24" of fill is brought in at any one place. 4. All setbacks shall be met 5. All appliances shall be protected from car impact in garage. 6. Return air in all bedrooms. FBCR M1620.4 7. Ground mounted A/C units shall be anchored per FBCR M1307.3.1 8. Lot shall be graded as to comply with 401.3 of the F.B.C. 9. Drainage Plan Requirements must be met: Ordinance no. 974-07 Section 6. Attached. This comment sheet shall be kept with the permit and/or plans. / .( C Kalvin Switzer— ans Examiner Date 96iactor and/or Homeowner (Required when comments are present) Lot 15 1 Lot 6 I I 1 � L----------------------------- 1 I I 1 I 1 � Lot 14 1 Lot 7 1 I 1 1 ------------� ------------------, - ------------------'II ' 1 i FL003 ELEVATION '1 CONSTRUCT SWALE I Lot 13 �06p.3 ,p.s Lot 8 X f ° 1 X °' Xe.a 331 � ------------, \°gX1O2�'1 O. 140O"(R) S. 64.51'12' W. - 140. (M)-----j I Qg---yC99ga A t°' -------- a „A" - Lot 12 " GARAGE "q 93 rnI m () Lot 9 EXISTING FLOOR ELEVATI ,X _- �0 MASONRY RESIDENCE w __ NDER CONSTRUCTION 19.7' USTING w i N =10.94 031 6.0' X9' Lot 11 ; 7 Y ------------- ----- --- --jO.A 10.2 °A `' 1 POSITION S. 64.49'40' WERM . - 14 3' (M) AROUND EXISTING WCAMPHOR TREE ALE AND B o (TREE NOT SHOWN ON SURVEY) ' CONSTRUCT SWALE REMOVE MULBERRY TREE X �e, 3 FlELD LOT TO ALLOW FOR SWALE 9' AROUND C 0.31 O 03 STREE RV NOT O pa TBM81 - ELEVATION ASSUMED I ---------------------------------- o i m -- - - — "I � w / n � U I Ps' ' / SWALE VIDTH 10'3 / Vl / ., SOD SLOPES SOD SLOPES SECTION "8"-"g" SECTION 'A"-';q" SOUTH SWALE SHOWN DIVERSION SWALE NORTH SWALE SIMILAR (NOT TO SCALE) (NOT TO SCALE) Vl SECTION p, TOWNSHIP N ASCp C�U S., RANGE 21 E. v ' 7'�; FLORIDA ,I 1 / fig$ I1 E a i 1 / I / , 955 X VALLEY DRIVE AS �/ S ROADSIDE SVALE / , SCALE: 1" = 60' o / I A N 0' z A X DRAINAGE 120 off: NOTES: a a.80 BySTING JOHN ELEVATIONS LSS ARE BASED ON TOPOG ON ASSUMED DATUM ACCORD/NG TOH/C SUf7VEy 9.5 k M4ppER WORK ORDER NUMBER B RVE4T DATED 06 0604, THAT SURVEY /17/2008, AND ARE BASED EXISTING ELEVATIONS ARE SHOWN THUS X 0 PROPOSED ELEVATIONS ARE SHOWN THUS: 9 6 a7E SWALE S,p T�£E PROPOSED SURFACE FLOW 0 DIRECTION IS SHOWN THUS. "J 96 ENGINEER S DISCL,q IMER �cE�e1 The Floor Elevations others. This are existing and elevations, Plan 13 not intended to were dd established b 10.00 This is and this en ineer address floor y IA0UMa lot g g is not res rading plan on/ ponsible for same. LOT GR ADING PLAN LEGAL DESCRIPTION: Lots 9Q recorded in Plat Book 1, po a 10, Block 116, If'r ss 9 54, Public Records of OF ZEPHotILLS, of Pasco Couunty, Florida , FOR: � John Mulligan , ' 'I ¢ 0 J 0. WEST g- Z IONS COAST DESK; INC min 0 O U N CIML/SITE DEApN� � d �R O-020 WEST tOa, COAST DESIGN INC. j j 'TAMTS CATS a/1o/bs mow•SUITE LOT GRADING PLAN ISLAND,� I 205 ZEPHYRHILLS LOT GRADING PLAN PASCO COUNTY, LOTS g FLORIDA & 10, BLOCK 116 (� 1 TOWN OF ZEPHYRHILLS C I NOTES: I. The purpose of this Boundary Survey is to locate the in-process construction of form-boards for a proposed residential building on the subject property. No concrete foundation exists at this time. 2. This surveyor was not provided with a title search or abstract of title for the subject property. Therefore easements and/or other instruments of record may affect title and/or the boundaries of the subject parcel. 3. Bearings shown on this survey are based on the east line of Block 116, as monumented being N. 25°05'42"W. assumed. 4. No underground utilities were located on this survey. ---------------------------------------4 SCALE: 1" = 40' F° 414' conr,.t.Mananx0 Na w 0' 40' 80' 8th AVENUE 8 FaaM 4'x4' Conant No ID V FWlld 4'x4' Cm'ereb Yo o w N. 64'5719" E. — 360.05JMZ------------------ T---------- -------- 60.00' -- I I I I I I I I Lot 1 I I I I I I I I I I I I r---------� r--------------r - --------- � C> I I 1 1 — v 1 i I 1l Lot 2 --------- �--�\-------------------------1 I 1 II �I I Fouts 1' I n P , 1, I II End of Wood 3n. Foand 1/2'Inn Rod I I a No ID�I I I /—xFaw na't/2 Lot 8 .+a m cavpsueoet' I r/ JI I a II No ID EiM 03 N. I s I I '_'/ 140 (R) S. I 51'12 W. - 140.03' (M) I o, , I 1 a I I NI 66.00' 10 20.0' 0 I I ..N! Lot 9 I - " ► I 3NI t' Exterior Foundation L4 I-- ----� (�n1 ---------- 'o�i--- Form BOorda J Cn Cn ---- _ -20.0' o /2" -- . N�w o Lot 10 r o 0 I I m N m L---------] I 140' (R) S. 6449'40" W. - 140.03' (M) Fouad 1/2.� S. 6449'40" W. - 3?0.07' (M) ka„ I No w I 7th AVENUE 0 1 60' RIGHT OF WAY Fwna 4'x4' I 20`ASPHALT PAVEMENT CononM No-0- M .t I FouM 1" S.6449'40'W. - .297.33 , LEGAL DESCRIPTION Lots 9 & 10 Block 116 of TOWN OF ZEPHYRHILLS, as recorded in Plat Book 1, Page 54 of the public records of Pasco County,Florida. he IHE SURVEY DEP CIEU HERE S IWI COVERED U I PROEESSIUNAE UAUIEIIV INSURANCE, gong partytions or dprohib prohibited wiions to thouis t written map c sent of the other signing thp party. John Walsh, Professional Surveyor& Mapper Mulliganz Boundary Survey Client: John Work order number: W013--0203 31009 Pasco Road Phone: (352) 588-3680 Date of Survey: 02/27/2008 San Antonio, Florida 33576 Certified To: John Mulligan Certificate of authorization number LS 6061 Not valid without the sian.ture and the orininal raised sp�l 1909 ' N uo% v y .coIla(unS vp..L QI27O7.I `AJNfOO OOS6d ff I z 3JN6'X 'S 92' dIHSNM 0,L ` << Nors��s JO Vd C w 'Una t tM iaddew DUB JoAaiuns nasuanu pnuni-i pin NOTES: 1. The purpose of this Boundary Survey is to locate the in-process construction of form-boards for a proposed residential building on the subject property. No concrete foundation exists at this time. 2. This surveyor was not provided with a title search or abstract of title for the subject property. Therefore easements and/or other instruments of record may affect title and/or the boundaries of the subject parcel. 3. Bearings shown on this survey are based on the east line of Block 116, as monumented being N.25°05'42"W. assumed. 4. No underground utilities were located on this survey. SCALE: 1" = 40' Fpnd 4'x4' Cana W � No D 0' 40' 80' 8th AVENUE S Found 4'x4' o-4I r� No ID Found 4'o4' Conant.Mooun4rd N. 64'57'19" E. — 360.05'M1————— No ID ———————— —————— ————————————— , ' r-- 60.00 I I I I I Lot 1 I I I I I I I I I I I Nr----------1 -6 r-------------- — ----------1 I I I `11 I I Lot 2 I m1----------(� I-- -------------------------4 I `J ` I I Fond 1' OWi I2 V I II End of Wood Fa ax Found 1/2'Iron Rod I HOLD I I I Found 1/z Lot 8 .'tx D CapP9d O61' ' I y V I I II No IDN°d End a wood FMrq I v 0FY ;�---------� �II 140 (R) $ 64\5112 W. - 140.03' (M) Ig I I M 68.00 r 20.0' o 8 0 ' t� V,1I a L `Exterior Foundation i., o_ N D't�j -----1 �(r 01 --------- � Form Boards V: cn — N-------- —20.0' cn coil ——-— I (n Found 1/2' Ui I I �01 Found l o Lot 10 + I I � I I L---------J I 140' (R) S. 6449'40" W. — 140.03' (M) FwW 1 2 S. 6449'40" W. - 3?0.07' (M) I No ID o I 7th 4V JR 8 61RGHT oe NAY Found 4'x4' I 2n''ASPHALT PAVEMENT C000,00. � Manum4M No D Found 1' Irano O Na D I S.64'49'40'W. - 297.33 7 90 ' N uoi v s8a s,.to/an.cn12107,E `AIAT12OO OOST�d ` d0 ` Z !2 �0N6'?I S 9a dIHSNM0L I I N0LLD�S 30 Vd ,FS,,d. 'ys�D j u jeddeua pue aoiceMns pasuao!l eppo a Io !eas pasleW !eu!6uo ay} pue aJnaeu6is ay}Inoyf!M pl!eA ION 1.909 S-1 aagwnu uoijeziaogjne jo ajeoilpeo 9L5££ BPuo!d `o!uOluy ueg ue5tTtny� o: :on pat;t�aa� auo peoI nosed 6006£ goo / / o :Aanans ;o a;eQ 089£-889 (Z5£) : 4d COZO-9OM :aaquXnu aapao x.zoly ueslttn uuor :}uallo iedde j y ao/(a/Lns leuoIsseJoJd `uslee uqop �aa..MS /Ulopunog pod aqi UD Jbaay o 6q podea ao dowalatinsn s y} 01 suol}a opi,00 S o! p'd 30N�OSNI )llli8d111dN@1SS110Nd 11A001U SI 3N1N O]I d] I]A.NOS 1Nl •upuold`nlunoD oosad,lo spi000i oilgnd ogl Jo bS oSt'(1 I )l00 ld UI pop.a000a sl S'I-11H21AHd3Z 10 kMOI Jo 911 doolfl 01 6 shod MOhLdRIDS1Q lIV9311 FEB-28-2008 03:55P FROM:JOHN WALSH PSM 352 588 3680 TO:7800021 P.1 31009 Paaco Rd. • San Antonio,FL 33576 I II Phone/Fax(352)588-3680 • • • • k'11J.II Fax To: City of Zephyrhills Building Dept From: John Walsh,P.S.M. Fax: 813 760-0021 Pages: 2 including cover Phone•. 780-0018 Data: 2/28/2008 Re: Form Board Tie-in CC: 0 Urgent 0 For Review O Please Comment ❑Please Reply O Please Recycle •Comments:The survey is of Lots 9&10,Block 116,Town of Zephyrhills,Parcel ID11-26-21-0010- 11600-0090 at the comer of 7°i Ave & 13'" St, owner John Mulligan. Original copies to follow via. regular mail. FEB-28-2008 03:56P FROM:JOHN WALSH PSM 352 588 3680 70:7800021 P.2 NOTES: .J. The purpose of this Boundary Survey is to locate the in-process construction of form-boards for a proposed residential building on the subject property.No concrete foundation exists at this time. 2. This surveyor was not provided with a title search or abstract of title for the subject property.Therefore easements and/or other instruments of record may affect title and/or the boundaries of the subject parcel. 3. Bearings shown on this survey are based on the cast line of Block 116, as monumented being N.25°05'42"W.assumed. 4. No underground utilities were located on this survey. -------------------------------- SCALE: t" 40 F_I=+� N.o 0' 40' 80' 8th AVENUE 8 r«r.1C �! �----------', M.657.16 6o *e._J .o0JM� ------------ , ----- wo r-- I I I ----- 60.00' \I I I I Lot 1 I I I I I j ,fir----------I -r-------------- - --------- t $1 I I 1 T , , "I I I K Lot 2 I I �I---------- y--------------------------1 � I � v I I cI •B , II wr+.r'' Lot 8 -I v 1J Imo I y � II N.o cl I �I 140' (R) S. 64' 51'12' W. - 140.03' (M) I W 1---------- $ . I I F I I m 20.0 rn to I I ? 4 sees' c y 4 I I Lot 9 of .. ? j.. ieaNalba "t 4 ' t',e' -----------1 gem ---------- --r.--- 24Q uN ' 1 IAA i� ,or I I m J' c Lot f0 - o o^: I I ;m .,m I .� 1 I 1 140' (R) S. 64'49'40" W. - 140.03' (M) S.64'49'40 W. -]00.07'(M) "—'ry N,O $ I 7th AV.RNU ' 8 so'flour of WAY w.,,w• I 70'-4W 1414.T PAVE$D(r _\ S.64.49 40"W. -,297.33 , LEGAL DESCRIPTION Lots 9& 10 Block 116 of TOWN OF ZEPI IYRHILLS,as recorded in Plot Book I. Page 54 of the public records of Pasco County,Florida. THE SI a UU filED NERE 6 IWI COVERED V N EESSIONAI doll IURAMCE. p "led� sooty op l John Walsh, Professional Surveyor& Mapper Work order a b QQ_0203 31009 Pasco Road Phone:(352)588-3680 Date of Survey:.. 02/27/2008 San Antonio,Florida 33576 Certified To: John)--UttMigan Certificate of authorization number LS 6061 = - - Not valid without the signature and the original raised seal of a Florida licensed surveyor and mapper. 44,hn W.uSh; P.S PACE SECTION I t TOWNSHIP 26 S. RANGE 21 E. 1 OF ' PASCO COUNTY, FLORID ride. Surveyor' Regtiatra ' N . 6061 Periflo Associates STATE CERTIFIED GENERAL CONTRACTORS September 17, 2007 To Whom It May Concern: This letter is to inform you that John Mulligan is able to sign for permits in my behalf in your city. If you have any questions please feel free to contact myself at 561-212-2663. Thank yo for your time. andy Perillo 5501 Riva Ridge Drive Wesley Chapel,Fl 33544 Phone:813.994.7663 • Cell:561.212.2663 •Fax:813.433.2464 e-mail: randyperillo@yahoo.com Residential & Commercial • CGC 1508834 NOTES: 1. The purpo§e of this Boundary Survey is to locate the in-process construction of form-boards for a proposed residential building on the subject property. No concrete foundation exists at this time. 2. This surveyor was not provided with a title search or abstract of title for the subject property. Therefore easements and/or other instruments of record may affect title and/or the boundaries of the subject parcel. 3. Bearings shown on this survey are based on the east line of Block 116, as monumented being N. 25°05'42" W. assumed. 4. No underground utilities were located on this survey. ---------------------------------------1 SCALE: 1" = 40' Farad 4'"4'J No D 0 40' 80' 8th AVENUE 8 FCo'x4C000 �onun,.nt No ID n Found 4x4' N. 6419" E. - 360.05SMJ——————— Miarot I I 1 60.00' I I I I I I I Lot 1 I NI I I I I I I I I Nr--------- � r-------------,� -- ---------� NI I I I r.I I I I Lot 2 I I m----------C - ------- Q `J I V I II 0W, Fxd End of Wood F4nw Found 1/Z' Rod I I'a NID oI I Found t/s' 1.3 s Lot 8wv'LensMeoet' I 11 / N010 End of Wood F4no4 I I I II/ 140' (R) $ 64 51'12" W. - 140.03' (M) I o W 1---------- t 20.0' I C " �i Lot 9 o w Cn1 - Exterior Foundation C. o U�I Form Boards "CJ ----------.I 1 N W. -------- N-------- —20.0' U1 Found n Rat/2' O LOt 10 L---------� 140' (R) S. 6449'40" W. — 140.03' (M) S. 64'49'40" W. — 300.07' (M) Fouts NaID 1/2' won hh D 7th AVENUE $ o I 60 RIGHT'OF WAY Found 4x4" 1 20' ASPHALT PAVEMENT 1uonum.ot I F—d 1' I Na D r--- ------- {----------------------- tea• S.64'4940W. - ,297.33 7 LEGAL DESCRIPTION Lots 9 & 10 Block 116 of TOWN OF ZEPHYRHILLS, as recorded in Plat Book 1, Page 54 of the public records of Pasco County,Florida. 1HL SURVEY DLP CILD HERE IS W I iñTCOVERED BV I WI LJSIWNAL EIAUIE I I INSURANCE, going partytions or dpr prohibited without written map or sent report by other signing thparty. John Walsh, Professional Surveyor& Mapper dyMulliga�z Bounar Survey Client: John Work order number: W0C--0203 31009 Pasco Road Phone: (352) 588-3680 Date of Survey: 02/27/2008 San Antonio, Florida 33576 Certified To: Johr. Mulligan Certificate of authorization number LS 6061 Not valid without the signature and the original raised seal of a Florida licensed surveyor and mapper. Ohm Walsh, P.S PA GE SECTION 11 ' OF ' TOWNSHIP 26 S. RANGE 21 E. �i/� L PASCO COUNTY, FLORID rida Surveyor' Registration N1 6061 NOTES: 1. The purpose of this Boundary Survey is to locate the in-process construction of form-boards for a proposed residential building on the subject property. No concrete foundation exists at this time. 2. This surveyor was not provided with a title search or abstract of title for the subject property. Therefore easements and/or other instruments of record may affect title and/or the boundaries of the subject parcel. 3. Bearings shown on this survey are based on the east line of Block 116, as monumented being N.25°05'42" W. assumed. 4. No underground utilities were located on this survey. ---------------------------------------1 SCALE: 1 = 40 0-ore,;uonM=n; No ID 0' 40' 80' D, 0 8th AVENUE o Found 4'x4' Conoreto Yonllment No ID Found 4,. ConanrG t4onumont N. 6457'19" E. - 360.05SM_L------------------ No 10 I I 60.00' t`—— I I I I I I Lot 1 I I I I - I or--------- - r-------------- --------� tnl I 1 —�— I -- I I I I ----------- ; I I I! Lot 2 I iI---------- CI-- --------------------------1 I 1 1. I I Won 1' 0 I 1 I End«Wooe1 jnw Found 1/2'Iron Rod I Noo 100 II Found 1/2' Lot 8 pith 0 Cap'75NeD61' V I I Q II No 10 0d End w wood FD.nc. - 1 Y "1 ———— 140' (R) S. 64' 51'12" W. - 140.03' (M) I c ---------- ' ----- I o cn1 68.00' 20.0' O 3 Nl 1 W �Lot9 8W N �� " Cn Exterior Foundation w o A N Fortn Boarde - `''Cn " L --------- ��'cn. ---------- N-------- —20.0' to cn ► I I C, Iron i/2 2 O N P 4 ^m No 10 o Lot 10 o o^' I I ' 54. 3N L---------J S. 64.49'40" W. - 300.07' (M) 140' (R) S. 6449'40" W. - 140.03' (M) Found 1r� I Na m 8. 7th ATWX l ' s I 6a'fJxr W v sa F000d 4 x4 I 20 N T-i(�)<M No Found 1' I Noo ID T — S.64'49'40"W. -29---------------------- ---y LEGAL DESCRIPTION Lots 9 & 10 Block 116 of TOWN OF ZEPHYRHILLS, as recorded in Plat Book 1, Page 54 of the public records of Pasco County,Florida. INL SUR V DEPICTED HERE IS NOI COVERED BY PROFESSIONAL LIABILITY INSURANCE, Additions or signing deletions to prohibited without written map c sor ent report fthe other signing t party.the John Walsh Professional Surveyor& Mapper Boundary Survey y pp Client: John Mulligan Work order number: W08-0203 31009 Pasco Road Phone: (352)588-3680 Date of Survey: 02/27/2008 San Antonio, Florida 33576 Certified To: John Mulligan Certificate of authorization number LS 6061 Not valid without the signature and the original raised seal of a Florida licensed surveyor and mapper. n ►'Yalsh, P.Sabi. PAGE SECTION 11 / z TOWNSHIP 26 S. RANGE 21 E. 1 OF 1 PASCO COUNTY, FLORI Flonda surveyor's Registration N . 6061 2008 City ieph" rh1��=..