Loading...
HomeMy WebLinkAbout08-7315 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 7315 BUILDING PERMIT SINGLE FAMILY RESIDENTIALUiI Permit#:7315 Issued: 6/23/2008 Address: 37604 DALIHA TERR#22 LOT 211 Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range: Proposed Use: TOWNHOMES Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: Total Fees: 6,027.52 Subdivision: EILAND PARK TOWNHOMES Amount Paid: 6,027.52 Date Paid: 6/23/2008 Parcel Number: 03-26-21-0230-00000-2110 Name: LENNAR HOMES INC Name: LENNAR HOMES INC. Addr: 600 N WESTSHORE BLVD. STE 900 Address: 600 N. WESTSHORE BLVD TAMPA,FL. 33609 TAMPA, FL 33609 Phone: Lic: Phone: (813)769-5277 Work Desc: NEW TOWNHOME - ST CROIX- LOT 211 - 1392 SQ FT BUILDING FEE 650.58 ELECTRICAL FEE 130.28 PLUMBING FEE 86.85 MECHANICAL FEE 60.80 RADON 13.92 SEWER CONNECTION RESIDENT 2,010.00 WATER CONNECTION RESIDENT 641.00 WATER METER RES 3/4" 220.00 FIRE PLAN REVIEW FEES 93.28 FIRE INSPECTION FEES 13.50 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES TOWNHOMES 769.56 SCHOOL IMPACT FEE-sfr/100% 1,740.00 SCHOOL IMPACT FEE-sfr/1% 17.40 TRAFFIC IMPACT FEE 99% -963.27 TRAFFIC IMPACT FEE 1% -9.73 FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c)when extra inspection trips are necessary due to any one of the following reasons: a)wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d)work not ready for inspection when called e) permit not posted on job site f) plans not at job site g)work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to you property. If you intend to obtain financing,consult with your lender or an attorney before recording you no - f commencement." CONT GNATURE PERMIT OFFI P MIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 37614 Daliha Terrace #7321 r 37616 Daliha Terrace #7322 ------------------------------------ ------------- ------- ------ -- - rm out appiication completely. Owner&Contractor sign back of application,notarized If over$2500.a Notice of Commencement Is reaulred. (A/C unarades over$50001 NOTICE OF;DEED,RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which maybe more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed rei tfiatlar . UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has.hired a contractor or contractors to undertake'work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or Intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND.RESOURCE RECOVERY FEES: The undersigned understands that Transportation impact 1Fees'.and'Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The•undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to "certificate a of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must..be.•paid prior to permit Issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work Is $2,500.00 or more, I certify that I, the.;applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prep, red by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"awner" `I certify that I have obtained a copy of the above described document and promise in good faith to y deliver it to the owner prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain`a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that i understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest `.Florida Water Management District-Weals, Cypress Bayheads, Wetland Areas, Altering Watercourses Army Corps of.Engineers-Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks US Environmental Protection Agency-Asbestos abatement. - FederalI understand that the following viation restrictions apply to y-Runways. unthe use of fill: Use of fill is not allowed in.Flood Zone"V' unless expressly permitted. if the,fill material us to be used in Flood Zone " ", it is understood that a at time of permitting which is prepared rby agp ofessionale plan rengi engineer "compensating volume" will be submitted licensed by the State of Florida. If the fill material is to be used in Flood Zo te "A" in area within the stem wnwith permitted building using stem wall construction, I certify that fill will be used onlyo affect if fill material s to be used in any dve sell affec adjacent properties, the will owner mayrbelcit d forviiolating properties. .If use of fill Is found to adversely the conditions of the building permit issued•under the attached permit application, for lots less than one ( ) acre which are elevated by fill, an engineered drainage plan is required. I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner W e permit may bpermitting requg required for conditions electrical forth work this affidavit prior to commencing'construction. as,or other installations that ll not specifically included in the application. A plumbing,.signs, wells, pools, air conditioning, g not as ermit issued shall be construed to be a license to proceed suaith ncehof a permitp event authority to violate, Building Official fromiitheralter, or eafter set.aside a rovisions of the technical codes, nor shall of.re uirin a correction of errors In plans construction or violations i six of permit ipermit nce,Uordif work authorized by invalid q 9 unless the work authorized by such permit is commenced days and will demonstrate the ermit is suspended or abandoned fora period of is'fosanthnot to time ninety d ys commenced An extension P may be requested, in.writing, from the Building Official period considered abandoned. justifiable cause for the extension. If work ceased for ninety(90) consecutive days, th jb is ;RESULT IN YOiJR YOUR RECORD A NOTICE OF COMMENC NCiNG, CONSULT WARNING.TO OWNER TS TO R PROPERTY. IF YOU INTEND T . BT E E T. PAYING TWICE FOR IMPhO.„ Y BE ECO DING YOU N IT Y FLORIDA JURAT(R.S.117.03) CONTRACTOR f e m OWNER.OR AGENT s eFMBE t.� Subscribed and sworn to(o aE�EMdEti Subscribed and sworn to(or aff'i )bet produced /¢slf�'toatl by_ who Is/are erson a or roduced � as identification. Who fs'ersonail to me or has/h e n as identifica ion. z z r z O o O w r D U p 0 a w O J W Y N w �¢�� a� z oo�'� mw o0 a0vwi� 3O o m m - w11 z Q O 4 J z ¢~N z Ca w a� y z adV) wo 00 0 ( (M/21,42) z m o�WZ Nw =w �m J S,. sue. 3NV1 K—IH38W P _ - _ 0 - 5 z� x �J 9gJ rri wm0� ww a L —N w�WJ a U O\ Q a H~J O C w Mmww �� a ?w zw Z,wa a z U) ,m w=j Oo D s0 qw LSz Ha (�r rr C:r. J �cn 000 z�' V)ic�wa mc� m¢a Ow =¢r ¢ zz= 00 warn= wz Iwow Q ��F-w OOcn Oz OQ_d U UW (n 2� z N •NIVM ON00 ,S N O F�f1 , I ',00'68 M.94,12.00 S i�� 0 u m 0£ _ „l 3 iV0S C.) 0/y O m U a 8 8-L£ 8-,L£ U Z 0 W ✓ nW S �0 O p� w w ITiI n U 6 ^ ry N ^ N m Z M z Um • W z (n N o (� Sf Sf W a I ` � 8iI - . I _ - UQ ao �gF• �s N w N N y o. G °tea < oZi �A `a o O6N s98 U OJ D Z F VD . a D Z0, / Y O 89'£ Sf'Sf c I/� / ( //(n/ ~ O N/ Ti Vf aAJ 3 94,12.00 N a Q. (8r a f w BAj U�d 0 c O per= w 3 zaz0 '. Z J < 0 O 00 ZCN � a6W mOz o N I Q O m vi g O to a. - v�o� aaw o I Q. NDO I ,-z O On Ov) zo = azz W OF- Jin W�Jo 000 8w li LL.W W li 4-Ii ti W W L li J NP v)i N N Q Q ch OlOWo v (nn Iillilllllllll w i o I t I l i l l l l l l l Z (n o I I I I I I I I I l i l l c OE ui C4lpta sol 1¢10•1 0•10•1 M z < P M1z��1�1z 21011—Miz�IMi ° z> Q I I I I I I I I I 0 w unuuouno11 ° u till u W UJj UJ w II w NON W O 11 W� Ww II Q�o�O a a 3zo'a' mcYi II Y OOQ�cncw7 -o y j )0 N Z 0 [' °wa ,..< < ° W J WIZ �, O i w ado oP E z" � aa a Ww <OUaYw0Or �VI m �'� c7U<C) UH ZramwO�ci�3 • F�>F0ZOWWZrw Q� 00 < �3 >QwQQ> `off p SZ<0<00 ,0S00ox 0cr c o w O J W JJ wo0 a a 0<Vr(n 0 J a ZJaWNx C.J JCDW ZOJ ° NI d O1 NI a � z W Z Y W W S W< )/V .,.,26LL a�x N mwzam a r9fi b l g 0 II O II N ..N O O W Naa © U S9'64 a «-z o m 86'Ll u T��8q[ vOi C, o W Jp `�;►. K v Lri m a ,- II O) f1 - r rn a Jz m N d� QC) d 86 L1 zOZO z or a 0 86'L L N I ! U N Q Wa z i� U) - (n W p 0 N ff) Q <>0 n < U r86'L t \ w o r o oAln n< a V) r Z II O O ZL m op0 <M � _ 86Ll co O m z z- of O Wll < 00 W 11011 o0 i w Y U WYU fl vi I U< w <zam°a p I U 000,oy, m 19.64 0 r96'L l z 0 a -o 0• m QQ o0 _1000Z O N a zno <n N w C.7 M II W 0O O 0 (! p O mzz O 0 0•z <� a r86b1 00 a• 0l�- .0 1n U__ ssLl z ~ ? omW z W II Z < o a jO1 < 'J ZO _,) - to W N o a fa. 'W ~ W Z W O Q J U D as Wz� OCO Ilmz�� amn 0° >< M v our V(A�1nom o 700 Q I < <3 <Z Wax Z< ULJNN } X OOmW 'Q<W < 0•K oNN i— 000 •o a�1110•L Wo w 0m00 W =ova N �< N O O w 2 <0 r 7 << mm U NI O U fl W d n NO V CZ7 WOn II (rUw33 Wm V=i0o�° �J� T Q U < zic f i O J N a vo O�ti 0) M WNo a.f Z 0 0_ -WW O o Uov i r O 00 - 0 W1�J <> m U 3 ZO d O ♦U♦ NOO W OtoL) r zV) 16-- VIInOW t- UU 'U O < UPI Ljaw�- �z a p=U J�U U-a0 03 z�-J Il iiIIIIIIIIIIIIIII111111111IIIIDIII11111IIIIIII 2008089274 Rept: 1186756 Rec: 10.00 DS: 0.00 IT: 0.00 06/16/08 Dpty Clerk JED PITTMAN. PASCO COUNTY CLERK 06/16/08 11:57am I of 1 NOTICE OF COMMENCEMENT OR BK 7861 PG 1938 Permit No. Property Identification No;' 3-2(.-,Z/- p�30-pp o O- THE UNDERSIGNED hereby give informs you that the improvement will be made to certain real property,and in accordance with Section 71313 of the Florida Statutes,the following information is provided in this NOTICE OF COMMENCEMENT. 1.Description of property(legal description:) ILor 2ll ,tToe /NowS P3 Go PG/O�, a)Street.Address c( AA6/#4 -r '&f 2.General description of improvements 4esiyevcc /fo_ /.ScddAJ ENc�.osu�E 3,Owner Information a)Name and address: LEWNAK '4'O,4fE.j C- 600 /V. desrJNo&E 34yD, - q.Npy p,,,,'t. 33401 b)Name and address of fee simple titleholder(if other than owner) c)Interest in property 4,C or Information Name and address: •Yr,ye S'm,r'/ (p00 Al 1 Vo2E l3avo Sre 600 y,T,4ief h 33o7 Telephone No,: ($13) 749-52'?? Fax No. (Opt.) 5.Surety Information a)Name and address: /✓_A b)Amount of Bond: N LA _ c)Telephone No.: Fax No. (Opt.) 6.Lender a)Name and address:___________________________________________________ Phone No. 7. Identity of person within the State of Florida designated by owner upon whom notices or other documents-may be served: a)Name and address:.S'rEVESwi r,I— (d ,V- Lt/esTJNORf &vD, .YTE OOd rAMttA , fit 33609 b)Telephone No.:..( l 31 7 9—_527? Fax No. (Opt.) 8.In addition to himself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes: a)Name and address: _V1f9 b)Telephone No.: Fax No. (Opt.) 9.Expiration date of Notice of Commencement(the expiration date is one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE.CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART I,SECTION 713.13, FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS.TO YOUR:PROPERTY . A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT YOUR LENDER OR AN ATTORNEY BEFORE. COMMENCING WORK OR RECORDING YOUR NOTICE OF COM MENT. STATE OF FLORIDA `n COUNTY OF PASCO L V Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager 4cyyec 64lNS Print Name The foregoing instrument was acknowledged before me this I3rµ day of J yt J t 20.0 a by /4.'e,q,466 k .S'7EpRNS as Nl4NAGE2 (type of authority,e .officer,trustee,attorney in fact)for LEN/yA C O fe.'Oo94 Zlo4 (name of party on behalf of whom' ent was executed). Personally Known ✓ OR Produced Identification Notary Signature 'f Type of Identification Produced. Name(print) £_i S s'A i/a Verification',pursuant to Section'92.525,Florida Statutes.Under penalties ofperjury,I declare that l have read the foregoing and that the facts stated in,it are true to the best of my knowledge and belief. Signal o N on.Signing Above ORMSfNOCtvad200T ELISSA M.HOLLERAN f«r .. Commission DD 774023 : r Expires June 6,2012 ,., Baaoa nw troy Fain Yw�Ka eoo-sesmto STATE OF FLORIDA COUNTY OF PASO THIS IS TO GERTIFY THAT THE FOREGOING iS A TRUE AND CORRECT COPY OF THE DOCUMENT ON FILE OR OF PUBLIC RECORD IN THIS OFFIC WITNESS MY H D AND OFFICIAL SEAL THIS DAY OF p TMA ERK OF CIRCUIT COQ_ ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Fire Chief Keith Williams Bus (813)780-0041 Fax(813)780-0044 FIRE SERVICE USER FEES Occupancy No.: Plan No.: p Contractor: cc!/ Business Name: ,' 6 Billing Address: t,.1rBusiness Address: cr Billing Phone No.: 024!:2 C_ 3 CO Business Phone No.: ��T Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE Site Plan Annual N/C Sprinkler $50 1st Alarm N/C Mufti-Family/Commercial sf 1st Re-inspection N/C Standpipes $50 2nd Alarm N/C (Minimum Charge$25.00 2nd Re-inspection $100 Fire Pump $50 3rd Alarm N/C Plan Revisions DBL 3rd Re-inspection $250 Hoods $50 4th Alarm $100 4th Re-Inspection $500 Fire Alarm $50 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until LP Gas $50 6th Alarm $200 8 0-25 Heads $50 violations corrected) Natural Gas $50 NON COMPLIANCE $150 26 plus Heads $100 SPRINKLER SYSTEMS Fuel Tanks- per tank $50 STANDPIPE SYSTEM Hydro Undergrounds $45 Sparklers $100 Per Riser $50 Hydrostatic Test $65 per system Fire Works $500 FIRE PUMP Acceptance Test $45 per system Camp Fire $25 Per Pump $100 Hydrant Flow $75 Controlled Bum $100 FIRE ALARM SYSTEM Hood/Duct $50 0-25 Devices $50 FIRE ALARM SYSTEM Place of Assembly $50 Annual 26 plus Devices $100 System Acceptance $50 Fire Protection $25 SUPPRESSION SYSTEMS Recall Acceptance $50 Flammable Application $50 Annual Wet $50 OTHER Waste Tire Storage $50 Annual Dry $50 Fire Wall/Smoke Wall 15Kper Generator<KW $100 CO2 $50 LP Gas pertank Generator X30 KW 150 Other $50 Natural Gas $25 per system Bio-Hazard Waste $100 Annual KITCHEN EXHAUST Fumigation Tenting $50 Hood/Ducts $50 Tent 10x10'or greater $15 pertent Torch Pot/Applied $50 OTHER Fire Pump $45 Haz.Materials $100 Annual 8 LP Installation per tank $50 Fire Suppression $30 Fuel Tank Installation $50 System Acceptance (Per Tank) $50 H Exhaust Hood/Duct $30 Natural Gas Installation $50 Re-inspection DBL (Per System) (other than annual) Spray Booth $50 Inspection scheduled DBL and cancelled less than 24 hours Construction Insp. N/C Emergency Vehicle AG $50 � FALSE ALARM PLANS TOTAL INSPECTION TOTAL ✓� PERMIT TOTAL TOTAL GRAND TOTAL 0 Comments: Date: J �i! O Insgpcton <�/ Lennar-Daliha Terr-37604(lot 211) St. Croix Model-Permit#7315 SQ. FEET PRICE MAIN OR LIVING: 1,392 $ 94.99 OTHER AREA UNDER ROOF: - $ 94.99 OTHER: - $ - VALUATION $ 132,226.08 FEE SHEET $ 579.00 ADDRESS $ 30.00 DRIVEWAY $ 30.00 BUILDING: $ 650.58 ELECTRICAL: $ 130.28 PLUMBING: $ 86.85 MECHANICAL: $ 60.80 SUB-TOTAL $ 928.51 RADON: $ 13.92 TOTAL $ 942.43 SEWER: $ 2,010.00 WATER: $ 641.00 IRRIGATION: $ - TOTAL: $ 2,651.00 WATER METER: $ 220.00 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: $ 93.28 INSPECTION TOTAL: $ 13.50 PERMIT TOTAL TOTAL: $ 106.78 PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 4,473.56 PARK IMPACT FEES $ 769.56 SIF'S: $ 1,740.00 100.0% $ 1,740.00 1.0% $ 17.40 TOTAL: $ 1,757.40 T I F'S : $ (973.00) Minus Credit-check on balance 99%_$ (963.27)J Minus Credit-check on balance 1%_$ (9.73)J Minus Credit-check on balance TOTAL: $ 6,027.52 City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Ler,r r- Date Received: IZI13 IO-7 Site: 3"7(ooL}- I a— lecr *22. Lai-211 Permit Type: •-rOLQ5r rLQ Approved wino comments:❑ Approved w/the below comments: Denied w/the below comments: El e Q(q This comment sheet shall be kept with the permit and/or plans. XI __________________ Kalvin Switzer-Plans ' er Date Contractor and/or Homeowner (Required when comments are present) - '4 - -- * " j ik FORM 600A-2004R EnergyGauge®4.5.2 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: US1353SC-ST. CROIX- 1353 S.F. LIVING AREA Builder: U.S. HOMEDl er' Address: ?5Z(:.;C { � , �� � � •z l L Permitting Office: City, State: „��� Permit Number: '1345 Owner: Lenc�o�c -km�-o s Jurisdiction Number: (vlt(, Climate Zone: Central 1. New construction or existing New — 12. Cooling systems 2. Single family or multi-family Multi-family _ a. Central Unit Cap:28.8 kBtu/hr — 3. Number of units,if multi-family 4 — SEER: 13.00 — 4. Number of Bedrooms 3 _ b.N/A _ 5. Is this a worst case? Yes _ - _ 6. Conditioned floor area(ft2) 1353 ft2 c. N/A _ 7. Glass typeI and area:(Label reqd.by 13-104.4.5 if not default) a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a(Sngle Default) 185.0 ft2 — a. Electric Heat Pump Cap:27.8 kBtu/hr b. SHGC: HSPF:8.00 _ (or Clear or Tint DEFAULT) 7b. (Clear) 185.0 ft2 _ b.N/A _ 8. Floor types _ a. Slab-On-Grade Edge Insulation R=0.0, 103.0(p)ft _ c. N/A b.N/A _ c. N/A _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap:40.0 gallons a. Concrete,Int Insul,Exterior R=4.1,691.0 ft2 _ EF:0.92 — b. Concrete,Int Insul,Adjacent R=4.1,744.0 112 _ b. N/A _ c. N/A _ d. N/A _ c. Conservation credits e. N/A _ (HR-Heat recovery,Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=30.0,692.0 ft2 15. HVAC credits PT, _ b.N/A _ (CF-Ceiling fan,CV-Cross ventilation, c. N/A HF-Whole house fan, 11. Ducts _ PT-Programmable Thermostat, a. Sup:Unc. Ret:Con. AH(Sealed):Interior Sup.R=6.0,150.0 ft MZ-C-Multizone cooling, b.N/A _ MZ-H-Multizone heating) Glass/Floor Area: 0.14 Total as-built points: 17957 PASS Total base points: 18362 I hereby certify that the plans and specifications covered by Review of the plans and &-VUE ST�r this calculation are in compliance with the Florida Energy specifications covered by this do = _ A0 Code. calculation indicates compliance ' ''' _ PREPARED BY: with the Florida Energy Code. Before construction is completed DATE: this building will be inspected for 0 a I hereby certify that this bull ' signed,' n compliance compliance with Section 553.908 with the Florida Energy, Florida Statutes. cOD WEB OWNER/AGENT: BUILDING OFFICIAL• DATE: DATE: 7`2 ≥)2c- 1 Predominant glass type.For actual glass type and areas,see Summer&Winter Glass output on pages 2&4. EnergyGauge®(Version: FLRCSB v4.5.2) FORM 600A-2004R EnergyGauge®4.5.2 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: US1353SC-ST. CROIX-1353 S.F. LIVING AREA Builder: U.S. HOMES Address: ( ��Ltic ��s,r Permitting Office: City, State: �� ti � <�,L Permit Number: Owner: Jurisdiction Number: Climate Zone: Central 1 New construction or existing New — 12. Cooling systems 2. Single family or multi-family Multi-family — a. Central Unit Cap:28.8 kBtu/hr 3. Number of units,if multi-family 4 _ SEER: 13.00 _ 4. Number of Bedrooms 3 _ b.N/A _ 5. Is this a worst case? Yes _ _ 6. Conditioned floor area(ft2) 1353 ft2 c. N/A 7. Glass type I and area:(Label reqd.by 13-104.4.5 if not default) a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a(Sngle Default) 185.0 ft' — a. Electric Heat Pump Cap:27.8 kBtu/hr _ b. SHGC: HSPF:8.00 _ (or Clear or Tint DEFAULT) 7b. (Clear) 185.0 ft' — b.N/A 8. Floor types _ a. Slab-On-Grade Edge Insulation R=0..0,103.0(p)ft _ c. N/A _ b.N/A _ _ c. N/A _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap:40.0 gallons _ a. Concrete,Int Insul,Exterior R=4.1,691.0 ft' _ EF:0.92 _ b. Concrete,Int Insul,Adjacent R=4.1,744.0 ft' b. N/A c. N/A _ d. N/A c. Conservation credits e. N/A _ (HR-Heat recovery,Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=30.0,692.0 ft' 15. HVAC credits PT, _ b.N/A _ (CF-Ceiling fan,CV-Cross ventilation, c. N/A _ HF-Whole house fan, 11. Ducts _ PT-Programmable Thermostat, a. Sup:Unc. Ret:Con. AH(Sealed):Interior Sup.R=6.0, 150.0 ft MZ-C-Multizone cooling, b.N/A _ MZ-H-Multizone heating) Glass/Floor Area: 0.14 Total as-built points: 17957 PASS Total base points: 18362 I hereby certify that the plans and specifications covered by Review of the plans and THE sT this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance yt�~�'''. ,.;;•,,O'°� PREPARED BY: with the Florida Energy Code. DATE: Before construction is completed this building will be inspected for Florida Statutes. I hereby certify that.this'building,as ned, is in compliance compliance with Section 553.908 *l with the Florida Energy f 'VG,OD � OWNER/AGENT: BUILDING OFFICIAL: hA. .S DATE: DATE: _0- l7-cT 1 Predominant glass type.For actual glass type and areas,see Summer&Winter Glass output on pages 2&4. EnergyGauge®(Version: FLRCSB v4.5.2) FORM 600A-2004R EnergyGauge®4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: BASE AS-BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 1353.0 24.35 5930.0 1.Single,Clear SE 1.3 15.0 32.0 61.07 1.00 1953.0 2.Single,Clear SE 1.3 15.0 32.0 61.07 1.00 1953.0 3.Single,Clear SW 1.3 15.0 32.0 56.99 1.00 1819.0 4.Single,Clear SW 1.3 17.0 9.0 56.99 1.00 511.0 5.Single,Clear SW 1.3 9.0 16.0 56.99 0.98 896.0 6.Single,Clear SW 1.3 9.0 16.0 56.99 0.98 896.0 7.Single,Clear SE 1.3 6.0 16.0 61.07 0.92 897.0 8.Single,Clear SE 1.3 6.0 32.0 61.07 0.92 1794.0 As-Built Total: 185.0 10719.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 744.0 0.70 520.8 1.Concrete, Int Insul,Exterior 4.1 691.0 1.18 815.4 Exterior 691.0 1.90 1312.9 2.Concrete, Int Insul,Adjacent 4.1 744.0 0.65 479.9 Base Total: 1435.0 1833.7 As-Built Total: 1435.0 1295.3 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Wood 20.0 7.20 144.0 Exterior 20.0 4.80 96.0 Base Total: 20.0 96.0 As-Built Total: 20.0 144.0 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 692.0 2.13 1474.0 1.Under Attic 30.0 692.0 2.13 X 1.00 1474.0 Base Total: 692.0 1474.0 As-Built Total: 692.0 1474.0 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 103.0(p) -31.8 -3275.4 1.Slab-On-Grade Edge Insulation 0.0 103.0(p -31.90 -3285.7 Raised 0.0 0.00 0.0 Base Total: -3275.4 As-Built Total: 103.0 -3285.7 INFILTRATION Area X BSPM = Points Area X SPM = Points 1353.0 14.31 19361.4 1353.0 14.31 19361.4 EnergyGauge®DCA Form 600A-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 • FORM 600A-2004R EnergyGauge®4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: BASE a AS-BUILT Summer Base Points: 25419.7 Summer As-Built Points: 29707.9 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1:Central Unit 28800btuh,SEER/EFF(13.0)Ducts:Unc(S),Con(R),Int(AH),R6.0(INS) 29708 1.00 (1.08x 1.150x 0.85) 0.260 0.950 7784.9 25419.7 0.3250 8261.4 29707.9 1.00 1.061 0.260 0.950 7784.9 EnergyGaugeM DCA Form 600A-2004R EnergyGauge®/FIaRES'2004R FLRCSB v4.5.2 FORM 600A-2004R EnerdyGauge®4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: BASE a AS-BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOE= Point .18 1353.0 9.11 2219.0 1.Single,Clear SE 1.3 15.0 32.0 10.59 1.01 341.0 2.Single,Clear SE 1.3 15.0 32.0 10.59 1.01 341.0 3.Single,Clear SW 1.3 15.0 32.0 11.59 1.00 371.0 4.Single,Clear SW 1.3 17.0 9.0 11.59 1.00 104.0 5.Single,Clear SW 1.3 9.0 16.0 11.59 1.01 186.0 6.Single,Clear SW 1.3 9.0 16.0 11.59 1.01 186.0 7.Single,Clear SE 1.3 6.0 16.0 10.59 1.04 176.0 8.Single,Clear SE 1.3 6.0 32.0 10.59 1.04 352.0 As-Built Total: 185.0 2057.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 744.0 1.80 1339.2 1.Concrete, Int Insul,Exterior 4.1 691.0 3.31 2283.8 Exterior 691.0 2.00 1382.0 2.Concrete, Int Insul,Adjacent 4.1 744.0 2.08 1547.5 Base Total: 1435.0 2721.2 As-Built Total: 1435.0 3831.3 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Wood 20.0 7.60 152.0 Exterior 20.0 5.10 102.0 Base Total: 20.0 102.0 As-Built Total: 20.0 152.0 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM= Points Under Attic 692.0 0.64 442.9 1.Under Attic 30.0 692.0 0.64 X 1.00 442.9 Base Total: 692.0 442.9 As-Built Total: 692.0 442.9 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 103.0(p) -1.9 -195.7 1. Slab-On-Grade Edge Insulation 0.0 103.0(p 2.50 257.5 Raised 0.0 0.00 0.0 Base Total: -195.7 As-Built Total: 103.0 257.5 INFILTRATION Area X BWPM = Points Area X WPM = Points 1353.0 -0.28 -378.8 1353.0 -0.28 -378.8 EnergyGauge®DCA Form 600A-2004R EnergyGauge®/FIaRES'2004R FLRCSB v4.5.2 FORM 600A-2004R EnergyGauge®4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: BASE AS-BUILT Winter Base Points: 4910.5 Winter As-Built Points: 6361.8 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 27800 btuh,EFF(8.0)Ducts:Unc(S),Con(R),Int(AH),R6.0 6361.8 1.000 (1.068 x 1.160 x 0.87)0.427 0.950 2791.8 4910.5 0.5540 2720.4 6361.8 1.00 1.083 0.427 0.950 2791.8 EnergyGauge'rm DCA Form 600A-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 FORM 600A-2004R EnergyGauge®4.5.2 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: BASE AS-BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2460.00 7380.0 40.0 0.92 3 1.00 2460.00 1.00 7380.0 As-Built Total: 7380.0 CODE COMPLIANCE STATUS BASE AS-BUILT Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total Points Points Points Points Points Points Points Points 8261 2720 7380 18362 7785 2792 7380 17957 L1 PASS y�yo4 z srgp�o� a EnergyGaugeTM'DCA Form 600A-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 FORM 600A-2004R EnergyGauge®4.5.2 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT#: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENT FOR EACH PRACTICE CHECK Exterior Windows&Doors 606.1.ABC.1.1 Maximum:.3 cfm/sq.ft.window area; .5 cfm/sq.ft.door area. Exterior&Adjacent Walls 606.1.ABC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall; foundation&wall sole or sill plate;joints between exterior wall panels at corners; utility penetrations;between wall panels&top/bottom plates;between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from,and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members. EXCEPTION:Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter,penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls&ceilings;penetrations of ceiling plane of top floor;around shafts,chases, soffits,chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plate; attic access.EXCEPTION:Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter,at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated,installed inside a sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from conditioned space,tested. Multi-story Houses _ 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2.Switch or clearly marked cir breaker(electric)or cutoff(gas)must be provided. External or built-in heat trap required. Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated). Non-commercial pools must have a pump timer.Gas spa&pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically attached,sealed,insulated,and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics:R-6 min.insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1,602.1 Ceilings-Min. R-19.Common walls-Frame R-11 or CBS R-3 both sides. Common ceiling&floors R-1 1. EnergyGaugeT"'DCA Form 600A-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* =86.0 The higher the score,the more efficient the home. 1. New construction or existing New 12. Cooling systems 2. Single family or multi-family Multi-family _ a. Central Unit Cap:28.8 kBtu/hr 3. Number of units,if multi-family 4 SEER: 13.00 _ 4. Number of Bedrooms 3 _ b. N/A _ 5. Is this a worst case? Yes _ _ 6. Conditioned floor area(ft2) 1353 ft2 _ c. N/A _ 7. Glass type'and area:(Label reqd.by 13-104.4.5 if not default) _ a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a(Sngle Default) 185.0 ft2 _ a. Electric Heat Pump Cap:27.8 kBtu/hr b. SHGC: HSPF:8.00 (or Clear or Tint DEFAULT) 7b. (Clear) 185.0 ft2 — b.N/A 8. Floor types _ a. Slab-On-Grade Edge Insulation R=0.0,103.0(p)ft _ c. N/A _ b. N/A c. N/A _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap:40.0 gallons _ a. Concrete,Int Insul,Exterior R=4.1,691.0 ft2 _ EF:0.92 _ b. Concrete,Int Insul,Adjacent R=4.1,744.0 ft2 _ b. N/A _ c. N/A d. N/A _ c. Conservation credits e. N/A (HR-Heat recovery,Solar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=30.0,692.0 ft2 _ 15. HVAC credits PT, _ b.N/A (CF-Ceiling fan,CV-Cross ventilation, c. N/A _ HF-Whole house fan, 11. Ducts PT-Programmable Thermostat, a. Sup:Unc. Ret:Con. AH(Sealed):Interior Sup.R=6.0,150.0 ft _ MZ-C-Multizone cooling, b.N/A _ MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building qUE ST Construction through the above energy saving features which will be installed(or exceeded) in this home before final inspection.Otherwise,a new EPL Display Card will be completed ��„ '� based on installed Co eatures. Builder Signature: Date: Address of New Home: C' d', City/FL Zip: *NOTE.. The home's estimated energy performance score is only available through the FLA/RES co pufeipto am. This is not a Building Energy Rating. If your score is 80 or greater(or 86 for a US EPA/DOE EnergyStar'h'designation), your home may qualify for energy efficiency mortgage(EEA4)incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site at www.fsec.ucfedu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 850/487-1824. 1 Predominant glass type.For actual glass type and areas,see Summer&Winter Glass output on ages 2&4. EnergyGauge®(Version:FLKCSB v4.5.2) •MAR-19-2007 11:25 SIMPSON MECHANICAL 813 558 8578 P. 18 Load Short Form Jai: .'S7-CROIX-1363 S.F.1..•. - wrlghtsoft- Entire House dil�i•: -1a/�soas Bar:' SIMPSON MECHANICAL For U.S. HOMES D • • • Htg Clg tnfiltrefion'... Outside db(°F) 35 92 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD (°F) 35 17 Fireplaces 0 Daily range - L Inside humidity(%) - 50 Moisture difference(grub) - 65 HEATING EQUIPMENT COOLING EOUIPIINT Make Carrier Make Carrier Trade Base 13 Puron HP Trade Base 13 Puron HP Model 25HBA330A30 Cond 25HBA330A30 Coil FY4ANF030 Efficiency 8.3 HSPF Efficiency 93;SE R Heating input Sensible cooling 21570 Btuh Heating output 31800 Btuh c 47°F Latent cooling ' 7630 Btuh Temperature rise 29 °F Total cooling 292,00 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0,0;45 cfm/Btuh Static pressure 0.00 in H2O Static pressure •'O'00 in H2O Space thermostat 2 STAGE HEA Load sensible heat ratio Q;82 ROOM NAME Area Htg load Clg load Htg AV ' Cig AVF (F) (Btuh) (Btuh) (cfm) (cfm) LIVING 342 5182 3467 2161 ; 154 DINING 163 5567 5140 23Z 229 KITCHEN 120 2891 2647 12Q 118 POWDER 33 466 110 10 . 5 STAIRS 42 1186 280 4� 12 HALL 43 422 429 . 1a3 19 B.R. #2 160 1984 2438 83 109 B.R_#3 160 2858 3408 119 152 MASTER B.R. 195 2933 3945 122 . 176 MASTER BATH 52 495 505 2�" 22 HALL BATH 44 66 72 2 3 Bold/Mal/c values have been manuagy ovenydden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wnghtsoft Right-Sulte Resldontial 6.0.100 RSR43$13 t 2007 Matite 11;bl:47 Z:%Temmy HVAC1U31353SCJe,frp CeIc-MJ6 0 1enteF°n=NE Pegs 7 MAR-19-2007 11:25 SIMPSON MECHANICAL 813 558 8578 P. 19 Entire House 1353 24041 22442 1100'. 9000 Other equip loads 1483 720 Equip, . 0.97 RSM 22468 Latent cooling 4989 TOTALS 1353 25524 27457 1000'• 1000 a • Rofd/► rlo ve►ues have been menially Ovwrldden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wnghtsoft RigM-Suite Resldpnti016.0.100 RSR43B13 200T-Mer•1811:51:47 /ti les ZVTommy I VACWS1353SCJ9,rry C■b=Md8 Orientation=NE Page 2 ❑�❑ Kimley-Horn and Associates, Inc. November 17,2008 Suite 300 10117 Princess Palm Avenue Tampa,Florida Mr.Bill Burgess 33610-8300 Building Official City of Zephyrhills 5335 8th Street Zephyrhills,Florida 33540 Re: Eiland Park Townhomes—Lots 211-220 `? / lay Dear Mr.Burgess: I have reviewed the As-Built Surveys of the lot grading for the above subject lots and find them in general conformance with the approved Paving, Grading& Drainage Plan. The project is located east of Massey Road and south of Eiland Boulevard. At this time the plat has not been recorded and addresses have not been assigned. If you have any questions,please do not hesitate to contact me at(813)620-1460. Sincerely, KIMLEY-HORN AND ASSOCIATES,INC. W`RJtJ'^"^ f 11 dkk William J.Ma r,P.E. Senior Project Manager WJM:slk Attachment cc: Lennar Homes,Inc. ■ TEL 813 620 1460 FAX 813 620 1542