Loading...
HomeMy WebLinkAbout08-7405 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 7405 FIRE ALARM SYSTEM PERMIT .... Permit Number: 74Q5 Address: 39825 ALSTON AVE Permit1yp�: ' E ALARM SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 13-26-21-0040-00D00-0030 Improv. Cost: 9,800.00 Date Issued: Name: CITY OF ZEPHYRHILLS Total Fees: 150.00 Address: 39825 ALSTON AVE Amount Paid: ZEPHYRHILLS, FL. 33542 Date Paid: Phone: Work Desc: INSTALLATION OF FIRE ALARM SYS FOR NEW ADMIN BLD-PER KB CHRG SITESECURE INC FIRE ALARM 50.00 FIRE PLAN REVIEW FEES 50.00 FIRE INSPECTION FEES 50.00 8C� FIRE ACCEPTANCE Final FIRE ELEVATOR RECALL Chapter 633, Florida Statutes, authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." a., CONTRACTOR SIGNATURE I IC R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- Fire Marshal Office- 813-780-0041 SEP-15-2008 NON 01:48 PM FAX NO. P. 01/01 SiteSecure Inc. Engineers & Integrators PAGES INCLUDING THIS SHEET: 1 DATE: 9-15-2008 TO: The City of Zephyrhills ATTN: Permit Officer IROM: John Murray MESSAGE: In reference to permit#7405 for a fire alarm system at the water treatment facility located at 5335, 8th, Street.We are waiting on notification of the fire water system being far enough along for us to connect to for monitoring purposes. Once the fire water is ready to be monitored we can complete our system installation and call for inspection. We have no idea how far along the fire water system is or if it has even been started at this point. We will be but will be checking on the project tomorrow(9/26/2008). Please advise of any further action necessary on our part to extend our permit#7405 until the rest of the site is prepared for inspection.Thank you and have a great day! John Murray SiteSecure Inc. 627 Progress Way Sanford,Fl. 32771 V: 407-328-5220 F: 407-328-8346 Page 1 of 1 Jacqueline Boges From: Kerry Barnett Sent: Tuesday, August 19, 2008 10:54 AM To: Jacqueline Boges Subject: RE: question about permit No, they have not called in for an inspection. Kerry Barnett Fire Marshal, Zephyrhills Fire Rescue 813-780-0041 kbarnett(c�fire zephyrhills.fl.us From: Jacqueline Boges Sent: Tuesday, August 19, 2008 8:49 AM To: Kerry Barnett Subject: question about permit Have you inspected the fire alarm system at 39825 Alston Ave in the new building installed by sitesecure inc? Jackie C1. W v _ � 8/19/2008 Pasco County Parcel: 13-26-21-0040-00D00-0030 001 Page 1 of 1 Search Again Show Map Generalized Building Schematic Estimate Taxes Frequently Asked Questions Other Parcel Cards: 1 1 2 1 3 1 4 1 5 Other Agency Data: Tax Collector School Board Supervisor of Elections Data Current as Of: Weekly Archive - Saturday, March 01, 2008 Parcel ID 13-26-21-0040-00D00-0030 (Card: 001 of 005) Classification 89 - Other Municipal Mailing Address Assessment (totals) CITY OF ZEPHYRHILLS Ag Land $0 5335 8TH ST Land $5,313 ZEPHYRHILLS, FL 335424312 Building $82,863 Physical Address- See All 2 addresses (First Shown) Extra Features $513 39825 ALSTON AVE ZEPHYRHILLS, FL 33542-6733 Total Assessment $88,689 Legal Description (First 4 Lines) Save Our Homes $0 Z PINES NO 1 PB 4 PG 27 POR OF Taxable Value $0 E 1/2 OF LOT 3 BLK D DESC AS COM SW COR OF NW1/4 OF SE1/4 TH NOODG 09' 35"W 447.77 FT Land Detail (Card: 001 of 005) Line Use IIDescriPti0flhI Zoning Units Type Price IlConditioflhl Value 1 2000 AIRPORT 0AP2 13,283.00 SF $0.40 1.00 $5,313 Additional Land Information Acres V 0.30 I Tax Area II ZH I FEMA Code I X hlCommerical Codell IZAP6CA Building Information - Use 80 —Metal Buildings (Card: 001 of 005) Year Built 1955 Stories 1.0 Exterior Wall 1 Modular Metal Exterior Wall 2 None Roof Structure Steel Frame or Truss Roof Cover Min Roof(Corr. or Sh M) Interior Wall 1 Masonary or Minimum Interior Wall 2 None Flooring 1 Finished Concrete Flooring 2 None Fuel None Heat None A/C None Baths 0.0 Line Description 1 Sq. Feet Repi. Cost New 1 BAS 3,120 $47,206 2 UOAII 240 II $545 Extra Features (Card: 001 of 005) Line Description F Year Units Value No Extra Features Sales History Previous Owner N/A Year Month II Book/Page Type II Amount -- No Sales History -- Search Again Show Map Generalized Building Schematic Estimate Taxes Frequently Asked Questions Other Parcel Cards: 1 1 2 1 3 1 4 1 5 Other Agency Data: Tax Collector School Board Supervisor of Elections http://appraiser.pascogov.com/search/parcel.aspx?sec=13&twn=26&rng=21&sbb=0040&bl... 3/7/2008 813-780-0020 City of Zephyrhills Permit Application Fax-B13-7B0-0021 795 Building Department Date Received Phone Contact for Permitting P 1 I - Owner's Name City of Zephyrhills OwnerPhoneNumber Owner`sAddress 5335 8th Street Zephyrhills, FL Owner Phone Number 813-780-0000 Fee Simple Titleholder Name City of Zephyrhills Owner Phone Number Fee Simple Titleholder Address 5335 8th Street Zephyrhills, FL JOB ADDRESS 39825 Alston Ave. LOT# I SUBDIVISION I PARCELID# 13-26-21-0040-00D00-0030 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED ® NEW CONSTR B ADD/ALT = SIGN = MOVE DEMOLISH INSTALL REPAIR PROPOSED USE SFR COMM = OTHER TYPE OF CONSTRUCTION = BLOCK FRAME = STEEL = OTHER I DESCRIPTION OF WORK Installation of Fire Alarm System for new Administration Bldg BUILDING SIZE 1 SQ FOOTAGE I HEIGHT = BUILDING $ VALUATION OF TOTAL CONSTRUCTION ® ELECTRICAL $ 9 800 AMP SERVICE = PROGRESS ENERGY = W.R.E.C. PLUMBING $ MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION GAS ROOFING = SPECIALTY = OTHER (Jr `i/rry FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED Y/ N I FEE CURRENT Y/N Address I License# ELECTRICIAN COMPANY SiteSecure, Inc. SIGNATURE REGISTERED Y/ N I FEE CURRENT I Y/N Address 627 Progress Way Sanford, FL 32771 License# EF 0000718 PLUMBER COMPANY SIGNATURE REGISTERED Y/ N I FEE CURRENT Y/N Address I License# F MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURRENT Y/N Address I License# II OTHER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT Y/N Address License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans WI Silt Fence installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "`•"PROPERTY SURVEY required for all NEW construction. A Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$5000) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone"V'unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter, or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRALTO Subscribed and sworn to(or affirmed)before me this S bsc'be nd swore or afrgmed) ¢tore pftss by t /jD by t 0.Y1GtN Tfn t{'r Who is/are personally known to me or has/have produced o are personally known to rnd or has/have produced as identification. ____________________________________as identification. asidentification. Notary Public Cam 1. _Notary Public Commission No. Commission No. ay DANYEL FELDT Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped Commission# DD 617044 My Commission Expires November 26, 2010 D O ONHH x w 04 "ay d N 4w 00Lzi � w K rr rr tir c CV z 14 0O. F+•ts'm (.O a�o�z P1 ,< U1 Cb m r• ry 0 o 00 1 O H ao cr H ao w CD 0 r K 0-o w Oz' aoZL W p Hs' C �: mIIJ v'% O 0 I1 O _M nt D U]H z r w LC77 i 0 � H n� O ►�H � � a t� C o N N 00 ACORD OP ID DATE(MM/DD/YYYY) CERTIFICATE OF LIABILITY INSURANCE WHART-1 12/21/07 PRODUCER THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE Brown & Brown of Florida, Inc. HOLDER.THIS CERTIFICATE DOES NOT AMEND,EXTEND OR 2600 Lake Lucien, Dr. , Ste. 330 ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. Maitland FL 32751-7234 Phone: 407-660-8282 Fax:407-660-2012 INSURERS AFFORDING COVERAGE NAIL# INSURED INSURER A: Amerisure Companies 19488 INSURERS: National Union Fire Ine. Co. SiteSecure, Inc. INSURER C: 627 Progress Way INSURER D: Sanford FL 32771 INSURER E: COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED.NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTR NSR TYPE OF INSURANCE POLICY NUMBER DATE(MM/DD/YY) PDATE MN DD/YY)N LIMITS GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 A X COMMERCIAL GENERAL LIABILITY GL 2036108020007 04/01/07 04/01/08 PREMISES(Eaoccurence) '$300,000 CLAIMS MADE L•� OCCUR MED EXP(Any one person) $ 10,000 PERSONAL&ADVINJURY $1,000,000 GENERAL AGGREGATE s2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG s2,000,000 POLICY X JECT LOC EmpBen. 1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $1,000,000 A X ANY AUTO CA 2036107 01 04/01/07 04/01/08 (Ea accident) ALL OWNED AUTOS BODILY INJURY $ (Per person) SCHEDULED AUTOS $1K COME/COIL DEDS - PET A HIRED AUTOS & LIGHT BODILY INJURY $ (Per accident) A X NON-OWNED AUTOS $5K COMP/COLT.DEDS-NEAVY A X $50,000 Hired PD PROPERTY DAMAGE _—� — - (Per accident) AUTO ONLY-EA ACCIDENT $ GARAGE LIABILITY ANY AUTO OTHER THAN EA ACC $ AUTO ONLY: AGG $ EXCESS/UMBRELLA LIABILITY EACH OCCURRENCE $20,000,000 B X OCCUR CLAIMSMADE BE6564391 04/01/07 04/01/08 AGGREGATE $20,000,000 DEDUCTIBLE X RETENTION $10,000 _ $ WORKERS COMPENSATION AND X TORY LIMITS ER A EMPLOYERS'LIABILITY WC2036109 04/01/07 04/01/08 E.L.EACH ACCIDENT $500,000 ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.DISEASE-EA EMPLOYEEI$500,000 OFFICER/MEMBER EXCLUDED? If yes,describe under E.L.DISEASE-POLICY LIMIT $500,000 SPECIAL PROVISIONS below OTHER DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES/EXCLUSIONS ADDED BY ENDORSEMENT/SPECIAL PROVISIONS Certificate holder is listed as additional insured with respects to general liability in regards to work performed by the named insured. *10 days for non pay. CERTIFICATE HOLDER CANCELLATION ZEPHYRl SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,THE ISSUING INSURER WILL ENDEAVOR TO MAIL *30 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT,BUT FAILURE TO DO SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER,ITS AGENTS OR City of Zephyrhills 5335 8th Street REPRESENTATIVES. Zephyrhills FL 33540 AUTHORIZED REPRESENTATIVE ©ACORD CORPORATION 1988 ACORD 25(2001/08) JAN-14-2008 NON 03: 17 PM FAX NO. P. 01/01 �`' ?-� - SEMINOLE COUNTY BUSINESS TAX RECEIPT R Ay VALUES, SEMINOLE COUNTY TAX COLLECTOR PO Bin (i30 • Sanford, FL 32772-0t 30 " Tcicphonfe: 407-665-1000 � ��w .scmi.nalctax.nr 4• � 1�Y w-C 1.P� �. w � VALID THROUGH 09/30/08 SITESECURE 1NC Account#:123410 627 PROGRESS WAY SANFORD,FL 32771 REGULATED RONALD F DAVOLI (PRES) State Lic.#-EF0000718 Qualifier-RANDY PINKHAM Receipt#:10172007090504773 Amount Paid: $45.00 Date Paid:09/05/2007 Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (813) 780-0041 Kerry Barnett Fax(813) 780-0044 January 16, 2008 I have reviewed and approved the plans for a fire alarm system located at 39825 Alston Ave for the Water Treatment Plant. I have attached the comments for the plan approval. If there are any questions please contact my office at 813-780-0041. 1. Add additional smoke in hallway. 2. Install in accordance with NFPA 72, latest edition. 3. Label all indicating devices so they match the alarm panel. 4. Provide zone map by alarm panel. Inspections Required 1. Acceptance test ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Fire Chief Keith Williams Bus (813)780-0041 Fax (813)780-0044 FIRE SERVICE USER FEES Occupancy No.: C 9 Plan No.: 3- Contractor. J Business Name: L. Billing Address: ro r Business Address: v �. Business Phone No.: Billing Phone No.: Business Fax No.. Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE 8 Site Plan N/C Annual N/C Sprinkler $50 1st Alarm N/C Multi-Family/Commercial .06 sf 1st Re-inspection N/C Standpipes $50 2nd Alarm N/C (Minimum Charge$25.00 2nd Re-inspection $100 Fire Pump $50 3rd Alarm N/C fl Plan Revisions DBL 3rd Re-inspection $250 Hoods 4th Alarm $100 4th Re-Inspection $500 Fire Alarm 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until LP Gas 6th Alarm $200 El0-25 Heads $50 Violation connected) Natural Gas $50 NON COMPLIANCE $150 26 plus Heads $100 SPRINKLER SYSTEMS Fuel Tanks- per tank $50 STANDPIPE SYSTEM Hydro Undergrounds $45 Sparklers $100 Per Riser $50 Hydrostatic Test $65 per system Fire Works $500 FIRE PUMP Acceptance Test $45 per system Camp Fire $25 Per Pump $100 Hydrant Flow $75 Controlled Bum $100 FIRE ALARM SYSTEM Hood/Duct $50 0-25 Devices FIRE ALARM SYSTEM Place of Assembly $50 Annual Li 26 plus Devices Jjj System Acceptance X50 Fire Protection $25 SUPPRESSION SYSTEMS Recall Acceptance Flammable Application $50 Annual Wet $50 OTHER Waste Tire Storage $50 Annual Dry $50 Fire Wall/Smoke Wall $15 per wall Generator<KW $100 CO2 $50 LP Gas $25 pertank Generator>30 KW 150 Other $50 Natural Gas $25 persystwn Bio-Hazard Waste $100 Annual KITCHEN EXHAUST Fumigation Tenting $50 flHood/Ducts $50 Tent 10'x10 or greater $15 per tent Torch Pot/Applied $50 OTHER Fire Pump $45 Haz.Materials $100 Annual LP Installation per tank $50 Fire Suppression $30 Fuel Tank Installation $50 System Acceptance ❑ (Per Tank) $50 Exhaust Hood/Duct $30 Natural Gas Installation $50 Re-inspection DBL (Per System) (other than annual) ❑Spray Booth $50 Inspection scheduled DBL and cancelled less than 24 hours Construction Insp. N/C____ R Emergency Vehicle Aa i FALSE ALARM PLANS TOTAL f; [J INSPECTION TOTAL PERMIT TOTAL TOTAL GRAND TOTAL Comments: Date: 1 Insp ctor: — Sitesecure,Inc. 627 Progress Way _ SiteSecure, Inc. Sanford,FL 32771 Tel:407-328-5220 Engineers&integrators Toll Free:877-SITE-123 i Fax:407-328-8346 www.SiteSecure.com FIRE ALARM SYSTEM FOR: CITY OF ZEPHYRHILLS, FLORIDA WASTEWATER TREATMENT FACILITIES EXPANSION OPERATIONS BUILDING SODIUM HYPOCHLORITE STORAGE CATALOG DATA SHEETS BATTERY CALCULATIONS hal i�f , ph�thih by Fire MT ro aides w th pian(S) Frith cc Farenhyt Single Loop Analog/Addressable Fire Alarm Control System IFP-100 IFP-100 is an intelligent analog/addressable fire control panel.The basic IFP-100 system has a single SLC loop and four notification appliance = u` MEA circuits that can be programmed for notification outputs or auxiliary power. IFP-100 also has a built-in dual line digital fire communicator, Form C 429-92-E Vol.XIV trouble relay, and two programmable Form C relays.The firmware has powerful features, such as detector sensitivity, day/night thresholds,drift compensation and pre-trouble maintenance alert. IFP-100 supports a variety of other devices that can be added to the system such as RA-100 remote annunciator, 5824 serial/parallel printer interface module(for printing system reports), and 5496 intelligent power module, and Hochiki or Intelligent Device Protocol(IDP)devices. Features • Built-in support for up to127 Hochiki devices or 99 IDP detectors and 99 IDP modules • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator for remote reporting of system activity and system programming • Central station reporting by point or by zone • Jumpstart®auto-programming • Supports Class B (Style 4)and Class A(Style 6 or Style 7)configuration for SLC • Distributed, intelligent power IFP-100 • Built-in synchronization for AMSECO, Gentex®, Faraday, System • 6 amp power supply and maximum charging Sensor®, and Wheelock®appliances capacity of 35 amp hours(An additional • Sensor sensitivity settings and day/night sensitivity setting cabinet enclosure is required for batteries in excess of 18 amp hours) • Automatic drift compensation • • Notification circuits configurable as 2 Class A(Style Z ,4 Class B(Style Integrated dead front panel protects operator 9 ( tY ) ( Y from exposure to electrical components Y), or auxiliary power for resettable, constant, or door holder power • The FACP enclosure features a Piexiglass® • Built-in annunciator with a backlit 80-character LCD display viewing window to protect annunciator • RS-485 bus provides communication to system accessories • Programmable to automatically display oldest • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC event first or display tally of system events • Two built-in Form C programmable relays rated at 2.5 amps at 27.4 VDC • Acknowledge function allows operator to keep track of event status • SLC device locator can be used to locate a single or multiple devices on a SLC loop • Programmable date setting for Daylight Saving Time • System automatically performs detector sensitivity test • 13 preset notification cadence patterns(including ANSI 3.41)and four installation user programmable patterns • Built-in RS-232 and USB interface for programming The IFP-100 can be surface or flush mounted. • Upload or download programming, event history,or detector status onsite or from a remote location using a PC and 5650/5651 Silent Knight Software Suite(SKSS) • Improvements in SKSS deliver five times faster upload/downloads • Non volatile event history stores up to 1000 events • 125 Software zones and 125 output groups SILENT 7550 Meridian Circle Maple Grove,Mn 55369-4927 PIN 350388 Rev E 04/21/06 KNIGHT 763-493-6455 Copyright©2006 Silent Knight 1-800-328-0103 Jumpstart-is a Registered Trademark of Fax:763-493-7475 Silent Knight by Honeywell http://www.farenhyt.com Compatibility Telephone The IFP-100 SLC supports multiple device types of the same Requirements: FCC Part 15&Part 68 approved protocol: Jack: RJ31X(two required) • Hochiki ' Approvals • IDP NFPA 13, NFPA 15, NFPA 16, NFPA 70, & You cannot mix Hochiki and IDP devices on a FACP. However, NFPA 72: Central Station; Remote Signalling; Local Protective any combination of addressable devices of the same protocol Signalling Systems;Auxiliary Protected Premises Unit; &Water can be used on the IFP-100. Deluge Releasing Service.Suitable for automatic, manual, See Hochiki Devices specification sheet(PN 350360)and IDP waterflow, sprinkler supervisory(DACT non-coded)signalling Device Protocol Devices specfication sheet(PN 350361)for services. more information. Other Approvals: UL Listed; CSFM 7170-0559: 142; MEA 429-92-E Vol.XIV Specifications Physical Ordering Information Flush Mount Dimensions: 14.5"W x 24.75"H x 3.5"D IFP-100 Intelligent Fire Alarm Control Panel. (36.8 W x 62.9 H x 8.73 D cm) SBUS Accessories Overall Dimensions: 16"W x 26.4"H x 4.65"D RA-100 Remote Annunciator. Same operation and (40.6 W x 67 H x 11.8 D cm) similar appearance to FACP annunciator. Weight: 28 lbs. (12.8 kg) RA-1000R Remote Annunciator. Four line LCD Color: Red annunciator with 20 characters per line. Red. Environmental RA-1000 Remote Annunciator. Four line LCD Operating Temperature: 32°F—120°F(0°C—49°C) annunciator with 20 characters per line. Humidity: 10%—93%non-condensing Gray. RPS-1000 Intelligent Power Module. Electrical 5496 Intelligent Power Module. Primary AC: 120 VRMS @ 50/60 Hz, 2.5A 5824 Serial/Parallel Printer Interface Module. Total Accessory Load:6A @ 27.4 VDC power-limited 5880 LED I/O Module. Standby Current: 170 mA 5865-3&5865-4 LED Fire Annunciators. Alarm Current: 325 mA 5883 Relay Interface Board. Battery Charging Capacity: 7 to 35 AH Hochiki and IDP Devices Battery Size: 18 AH max.allowed in control panel cabinet. See the specification sheets listed below for a complete listing Larger capacity batteries can be housed in RBB accessory of the Hochiki and IDP devices. cabinet. 350360 Hochiki Devices Specification Sheet. Notification Appliance Circuits 350361 Intelligent Device Protocol Devices Four circuits that can be programmed individually as: Specification Sheet. Notification Circuits: 3A per circuit @ 27.4 VDC, power-limited Miscellaneous Accessories Auxiliary Power Circuits:3A per circuit @ 27.4 VDC, 5650/5651 Silent Knight Software Suite. Provides power-limited programming, upload/download,and Indicator Lights event reporting. Alarm(Red): Flashes when in alarm; solid when alarm silenced 5670 Silent Knight Software Suite. Provides Supervisory(Yellow): Flashes when a supervisory condition facility monitoring. exists; solid when supervisory silenced RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit Trouble(Yellow): Flashes when a trouble condition exists; solid into FACP cabinet. Dimensions: when trouble silenced 16"W x 10"H x 6"D Silenced (Yellow): Solid when an alarm,trouble or supervisory (406 mm W x 254 mm H x 152 mm D) condition has been silenced but not yet cleared Power(Green): Flashes for AC failure; solid when power systems are normal SILENT This document is not intended to be used for installation purposes.We try to keep our KNIGHT product information up-to-date and accurate.We cannot cover all specific applications �■ ... or anticipate all requirements.All specifications are subject to change without notice. ®_ For more information,contact Silent Knight 7550 Meridian Circle Suite 100,Maple Grove,Mn 55369-4927.Phone:(800)328-0103, Fax:(763)493-6475. by Honeywell Made in the U.S.A. Farenhyt Addressable Pull Station Model SD500.PS and SDSOO-PSDA Addressable Pull Station The SD500-PS is a single action addressable fire pull station, and � ,. U IV!EA the SD500-PSDA is a dual action addressable fire pull station. The SD500-PS/PSDA feature rugged metal construction. A terminal 429-92-E Vol.9 strip on back of the pull station allows interconnection of the pull station to the SLC loop of a Silent Knight analog/addressable fire alarm control panel. The SD500-PS/PSDA is designed for indoor , use in non-explosive environments. The normally open initiating point contacts are gold-plated to avoid risk of corrosion. The SD500-PS/PSDA has been tested by UL for compliance to the requirements of the Americans with Disabilities ACT(ADA). Features • UL Listed • CSFM listed • ADA compliant • Key reset(Same key as Silent Knight enclosures) • Surface mount back box available • Terminals-accept up to 14 gauge wire • Extremely easy to operate • Corrosion-resistant gold-plated contacts. • Reflective label makes it easier to locate in low light • v�'M"�" The SD500-PS single action pull stations are operated by a pull on the front pull cover of the station. The SD500-PSDA dual action pull SD500-PS stations are operated by lifting up an access plate and then pulling forward on the front cover of the pull station. A plunger switch, wired to a self contained addressable module, is released as the Operating Voltage: 24VDC pull station opens to initiate the alarm. Once operated, the cover hangs down and can be seen up to 100 feet away. The pull station Standby Current: .55mA is reset by returning the front cover to the normal upright position Alarm Current: .55mA and relocking the station with a reset key. The reset keys are the Ambient same keys used on Silent Knight enclosures. Temperature: 32°F to 120°F The SD500-PS/PSDA includes a status LED which blinks, indicating (0°C to 49°C) that the addressable module is communicating with the loop. The Mounting: Single gang box status LED lights continuously during an alarm. A dip switch on the Optional Red Surface addressable module is used to set the unique address. Mount Box PS-SMBB Dual Action Conversion kit SD500-LK Included with SD500- PSDA or it can be ordered separately and used to convert SD500-PS to SD500-PSDAs (See illustration on SILENT 7550 Meridian Circle back page.) Maple Grove,Mn 55369-4927 763-493-6455 KNIGHT 1-800-328-0103 P/N 350254,09/02 Fax:763-493-7475 Copyright©2002 Silent Knight http://www.farenhyt.com i 3 r . t s r SLC...... _.._... .._._......_ ;. S Wiring Dimensions 4 SD500-LK Installation SILENT 7550 Meridian Circle, Maple Grove, MN 55369-4927 rv.rrrrrrrrr 1-800-446-6444 or in Minnesota 763-493-6435 KNIGHT FAX: 763-493-6475 World Wide Web: http://www.farenhyt.com Made in the U.S.A. Farenhyt Duct detector housing with Relay module(SD505-AHDR)and Remote Test Switch(SD505-DTS) SD505-ADHR / DTS Duct Detector Housing with Relay Module and Remote Test Switch The SD505-ADHR analog addressable duct smoke detector with built-in relay module detects products of combustion present in air moving through an HVAC system. The SD505-ADHR is compatible with the S0505-DTS , which provides remote annuncaition and testing capabilities for the SD505-ADHR. The SD505-ADHR is a heavy duty metal housing with a pre- installed fp „F?vA U detector base. When smoke is detected in a duct, the unit communicates the condition to the FACP. The panel, in turn, depending on programming, turns off fans, blowers, and other devices. The SD505-ADHR is designed to be used with the SD505-APS Photoelectric Smoke Detector and SD505-AIS Ionization Smoke f ` Detector. ( y Features • Two-wire connection to SLC • LED alarm indication and communication on sensor head • Rugged steel backbox with clear plastic cover • Installation template included • Large terminal connection screws • Interchangeable "plug-in" photoelectric or ionization heads • UL listed'"` • Alarm Relay rated at 120/240 VAC @ 10A to control HVAC SD505-ADHR power. • Built-in Trouble Relay SD505-ADHR Alarm: 75 mA@ 24 VDC Standby: 35 mA @ 24 VDC Specifications SLC Current: .082 mA Included Parts: Alarm Relay: 10A @ 120/240VAC Metal housing with 7.5"exhaust tube 10A @ 24 VDC SD505-4AB detector base Trouble Relay: 2.5 A @ 30VDC Installation template Air Velocity: 500-4000 fpm SD505-DTS 4 mounting screws (SD505-APS) SD505-DTS Specifications Accessories: 300-4000 fpm (SD505-AIS) Dimensions: Photoelectric Smoke Det.SD505-APS Height: 4.5" Ionization Smoke Det.SD505-AIS Sensitivity: 1.1 (SD505-APS) Width: 2.75" Sampling tube for 6"to 2.5'duct width 0.8(SD505-AIS) Depth: 1-5/8" STS-2.5 Ambient Color: Red Sampling tube for 2.5'to 5.0'duct Temperature: 32°F to 100°F width STS-5.0 (0°C to 37°C) Sampling tube for 5.0'to 10.0'duct Humidity: 10 to 85%RH width STS-10.0 Dimensions: 10"H x 8.25"W x Operating Voltage: 24VDCNDC, 2.25"D 120/240 VAC Color: Gray Current: SILENT 7550 Meridian Circle Maple Grove,Mn 55369-4927 I j KNIGHT 763-493-6455 P/N 350326 Rev. B,02/04 1-800-328-0103 Copyright©2004 Silent Knight Fax:763-493-6475 by Honeywell www.farenhyt.com FACP/5815XL Connection FACP/5815XL / Connection s. ' s+ IA C IN s pty�)TAIL- V ..T r(• t LC. SL( TRnu N,R I.idP LF.P .. .. .—.. Class B (Style 4) Class A(Style 6) J DTS connections SILENT This document is not intended to be used for installation purposes.We try to keep our r KNIGHT product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. .,, For more information,contact Silent Knight 7550 Meridian Circle Suite 100,Maple b Hone well Grove,Mn 55369-4927.Phone:(800)328-0103,Fax:(763)493-6475. Y Y Made in the U.S.A. Farehnhyt Analog,Addressable Photoelectric Smoke Detector SD505-APS In addition to accurately detecting a smoldering fire, each SD505- APS photoelectric detector has a unique address, which is recognized by the FACP. The SD505-APS compensates automatically for contamination in M EA F the environment. Detector calibration testing is simple—even from a remote site. The SD505-APS offers a low profile installation and uses the Model SD505-6AB base, compatible with other detectors 429-92-E, Vol. 9 APPROVED in the series, allowing for complete application and placement flexibility. Like other Farenhyt smoke detectors, the SD505-APS offers easy installation, stable operation, RF/transient protection, and vandal-resistant locking. Features -h{ IJ • Low profile, 2 inches, including base 09 L • Simple and reliable addressing without mechanical switches • Automatic compensation for sensor contamination • Built-in fire test feature �'°<r ` gip• • Simple detector calibration testing through the control panel or remotely through a WindowsTM based computer. (WindowsTM software required for remote testing.) • Vandal-resistance locking features • Field cleanable • UL listed, meets NFPA 72 Ch 7 requirements • CSFM Approved �` µa • MEA Approved • FM Approved Specifications Operating Voltage: 17-41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Operating Temperature: 32°F to 120°F (0°C to 49°C) Relative Humidity: 85% noncondensing Sensitivity: 0.88% - 3.56% FT Air Velocity: 0 - 300 FPM SILENT 7550 Meridian Circle Maple Grove,MN 55369-4927 KNIGHT 1-800-328-0103 763-493-6435(in Minnesota) P/N 350226 Rev C,05/16/05 by Honeywell Fax:763-493-6475 Copyright m 2005 Silent Knight http://www.farenhyt.com FACP/5815XL Terminal 5 or 6 6" Base — z P/N SD505-6AB Sc- s+ S -'N L SLC UT °�~l %' ` Terminal 1 or 2 Wiring to SLC Diameter=3-15116" Diameter=5-15/16" Height=:2 es including base f : ( ! _ ce wtnc�ti Model SD505-APS Model SD505-6AB (Top View) Detector Base (Top View) SILENT This document is not intended to be used for installation purposes.We try to keep our ,_ _„ KNIGHT product information up-to-date and accurate.We cannot cover all specific applications ■""■"'�'�■ or anticipate all requirements.All specifications are subject to change without notice. .� For more information,contact Silent Knight 7550 Meridian Circle Suite 100, Maple by Honeywell ll Grove,Mn 55369-4927.Phone:(800)328-0103,Fax:(763)493-6475. Made in the U.S.A. Farenhyt Dry Contact Input Module SD500-AIM & SD500-MIM The SD500-AIM and SD500-MIM are addressable input modules for UL MEA use with the Farenhyt fire alarm control panels (FACPs). The 429-92-E Vol.IX SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. Both input modules are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. "' p.�aR These modules are supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring fault conditions. If a fault occurs in the wiring, the SO500-AIM module alerts the FACP. Each addressable input module is programmed with a unique signal line circuit (SLC) loop address. Features • Single contact monitor • Support for Class A(Style 6& Style 7) or Class B (Style 4) wiring • Attractive ivory cover plate with the SD500-AIM SD500-MIM • Small and lightweight size allows for flexible mounting options with the SD500-MIM Compatibility • DIP switch programmable for fast installation The SD500-AIM and SD500-MIM are • Up to 2500 ft wiring distance from either input module to contact compatible with the following FACPs: • Use up to 14 gauge wire • IFP-1000 Intelligent Fire Panel • UL listed • IFP-100 Intelligent Fire Panel Installation • IFP-50 Intelligent Fire Panel The SD500-AIM mounts in a 4" square or double gang junction box The SD-500MIM mounts in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. SILENT 7550 Meridian Circle Maple Grove,Mn 55369-4927 KNIGHT 763-493-6455 P/N 350232 Rev C,05/04/06 1-800-328-0103 Copyright©2006 Silent Knight Fax:763-493-6475 by Honeywell www.farenhyt.com . Toc lad ...,.. � bAnlj nfOniki'4L7 c9t � AD Wv ' ` ff�MS'S�JU42Rt54'd "` FOWM L:iruSen To contact ococo d? EdV Specifications Environmental Physical Operating Temperature: 32°F— 120°F(0°C-49°C) SD500-AIM Humidity: 10%—93%non-condensing Width:4.9"(12.4 cm) als ov Height:4.9"(12.4 cm) Approvals v Depth: 1"(2.5 cm) Shipping Weight: 3.6 oz(120.1 g) UL Listed SD500-MIM CSFM 7300-0559: 132; Width: 1.5"(3.8 cm) Height:2.5"(6.4 cm) MEA 429-92-E Vol IX Depth: 0.7"(1.8 cm) FM approved for use with IFP-1000 Shipping Weight: 1.6 oz(45.4 g) Electrical Ordering Information Standby Current: 0.55 mA SD500-AIM Addressable Input Module Alarm Current: 23 mA max for one device; 46 mA max for two SD500-MIM Addressable Mini Input Module devices; 0.55 mA for each additional device Line Resistance: 50O max SILENT This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. ,...._ "® KNIGHT For more information,contact Silent Knight 7550 Meridian Circle Suite 100,Maple .. Hone ell Grove,Mn 55369-4927.Phone:(800)328-0103,Fax:(763)493-6475. y Made in the U.S.A. Farenhyt Two Form C contacts,2.OA @ 30 VDC or.6A @ 120 VAC SD500- ARM Addressable Relay Module The SD500-ARM is an addressable device that adds two M EA Form C contacts to the Farenhyt system. The contacts are F M rated at 2.0 amps @ 30 VDC or .6 amp @ 120 VAC. The 429-92-E, Vol. 9 SD500-ARM allows you to control a wide variety of normally APPROVED open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applica- tions can be located at any point in the signaling line circuit. Features • Two sets of Form C contacts. (Double pull/Double Throw relays) • Contacts are rated at 2A @ 30 VDC or.6A @ 120 VAC. • Up to 127 relays can be used on each SLC loop. • Relay programming is completely flexible—can be mapped to zone conditions. • Polling LED visible through cover plate. • UL listed, complies with NFPA 72. • CSFM approved • MEA approved o r' , • FM approved Spedfaations Contact Rating: Form C 2A @ 30 VDC or .6A@ 120 VAC Standby Current: .55 mA Alarm Current: .55 mA Operating Temperature: 32°F to 120°F (0°C to 49°C) Dimensions: 4-7/8"H x 4-7/8"W x 1"D Mounting: 4-square Compatible Control Panels IFP-1000 IFP-100 7550 Meridian Circle SILENT Maple Grove,MN 55369-4927 KNIGHT 1-800-328-0103 763-493-6455(in Minnesota) P/N 350219, 12/01 Fax:763-493-6475 Copyright©2001 Silent Knight http:l/www.farenhyt.com FRONT VIEW O O O O H 4-7/8" 1/4" Dimensions Contact 1 ^ 1 Contact 2 SD500-ARM Wiring SILENT 7550 Meridian Circle, Maple Grove, MN 55369-4927 KNIGHT 1-800-446-6444 or in Minnesota 763-493-6435 FAX: 763-493-6475 World Wide Web: http://www.farenhyt.com Made in the U.S.A. SYSTEM �$ SENSOR Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlert'Advance selectable-output horns,strobes, and horn/strobes are rich with features guaranteed to p� �� cut installation times and maximize profits. SPECTRNe� rt The SpectrAlert Advance series of notification appliances is Features designed to simplify installations,with features such as plug in Electrically compatible with existing SpectrAlert products designs,instant feedback messages to ensure correct installation of • individual devices,and 11 field-selectable candela settings for wall Automatic selection of 12 or 24 volt operation at 15 and 15/75 candela and ceiling strobes and horn/strobes. •Plug-in design When installing Advance products,first attach a universal mounting •Field selectable candela settings on wall and ceiling units:15,15/75, plate to a four-inch square,four-inch octagon or double-gang 30,75,95,110,115,135,150,177,185 junction box.The two-wire mounting plate attaches to a single-gang •Same mounting plate for wall-and ceiling-mount units junction box. •Shorting spring on mounting plate for continuity check before installation Next,connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. •Tamper resistant construction •Outdoor wall and ceiling products rated from-40°F to 151°F Finally,attach the horn,strobe or horn/strobe to the mounting plate •Design allows minimal intrusion into the back box by inserting the product's tabs in the mounting plate's grooves.The .Horn rated at 88+dbA at 16 volts device will rotate into position,locking the product's pins into the mounting plate's terminals.The device will temporarily hold in place •Rotary switch for horn tone and three volume selections with a catch until it is secured with a captured mounting screw. •Outdoor products UL listed to UL 1638(strobe)and UL 464(horn) outdoor requirements The SpectrAlert Advance series includes outdoor notification •Outdoor products rainproof per UL 50(NEMA 3R) appliances.Outdoor strobes and horn/strobes(two wire and four wire)are available for wall or ceiling.Outdoor horns are available for •Compatible with MDL sync module wall only.All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Agency Listings msiuure U: , r &,� NIEA _,s 1 ib':31R approved best LISTED APPROVED 5,'1'd.mom..chme;; 54011 ?C2357? :1[14',0€I »i2 53ic SpectrAlert Advance Specifications General SpectrAlert Advance horns,strobes and horn/strobes shall mount to a standard 4 x 4 x 1 Y'-inch back box,4-inch octagon back box or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 1 to-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync.Circuit"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 120124 volts.When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.Strobes and horn/strobes shall have field-selectable candela settings including 15,15/75,30, 75,95,110,115,135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system Horn/Strobe Combination The horn/strobe shall he a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous) pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns,strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn/strobe models over a single pair of wires.The module shall mount to a 40;56 x 4'1/,e x 2¼-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z (class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 1201(0°C to 49°C) K Series Operating Temperature -40-F to 151°F(-40°C to 66°C) Humidity Range 10 to 93%non-condensing(indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Range2 8 to 17.5 V(12V nominal)or 16 to 33 V(24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Wall mount dimensions(including lens) 5.61 x 4.7W x 2.5-D(142 mm Lx 119 min W x 64 mm D) Horn dimensions 5.61 x 4.7'W x 1.3D(142 mm L x 1 19 mm W x 33 mm D) Wall-mount back box skirt dimensions(BSS-2,BBSW-2) 5.90E x 5.0 W x 2.21)1151 mm Lx 128 mm W x 56 mm D) Ceiling-mount back box skirt dimensions(BBSC-2,BBSCW-2) 7.1'diameter x 2.25'high(180 mm diameter x 57 mm high) Wall-mount weatherproof back box dimensions(SA-WBB) STl x 5.1"W x 7.0"D(145 mm I x 130 mm W x 51 mm D) Ceiling-mount weatherproof back box dimensions(SA-WBBC) 7.1'diameter x 2.0"high(180 mm diameter x 51 mm high) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time varying pourer source that is used on some power supply and panel outputs 2.P,5,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data II] I] lflWIJI1 •IIF :r it • ii ii i"ii 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15* 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75* 142 148 77 81 Temporal Medium 44 49 58 69 30* NA NA 94 96 Temporal Low 38 44 44 48 75* NA NA 158 153 Non-temporal High 57 56 69 75 95* NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 8-17.5 Volts 16-33 Volts DClnput 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed candela ,. ratings must be reduced in accordance with this table. 24 Volt Nominal 8-17.5 16-33 Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at-40°F Position Sound Pattern d6 DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32°F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non-temporal High 82 82 88 88 93 92 100 100 95 70 5 Non-temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non-temporal Low 75 75 81 81 88 84 96 92 115 115 7t Coded High 82 82 88 88 93 92 101 101 135 135 gt Coded Medium 78 78 85 85 90 90 97 98 150 150 9' Coded Low 75 75 81 81 88 85 96 92 177 177 Settings 7,8,and 9 are not available on 2-wire horn/strobe. 185 185 ,' -O3vs-no_ SpectrAlert Advance Dimensions 5.6" Wall-mount horn/strobes Ceiling-mount horn/strobes 5.98" o O o o O O O C C Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Wall Horn/Strobes Ceiling Horn/Strobes(cont'd.) P2R*' 2-wire Horn/Strobe,Standard cd',Red PC2W*' 2-wire Horn/Strobe,Standard cd,White P2RH* 2-wire Horn/Strobe,High cd,Red PC2WH*' 2-wire Horn/Strobe,High cd,White P2RK* 2-wire Horn/Strobe,Standard cd,Red,Outdoor PC4R 4-wire Horn/Strobe,Standard cd,Red P2RHK* 2-wire Horn/Strobe,High cd,Red,Outdoor PC4RH 4-wire Horn/Strobe,High cd,Red P2W* 2-wire Horn/Strobe,Standard cd,White PC4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor P2WH* 2-wire Horn/Strobe,High cd,White PC4RHK 4-wire Horn/Strobe,High cd,Red,Outdoor P4R* 4-wire Horn/Strobe,Standard cd,Red PC4W 4-wire Horn/Strobe,Standard cd,White P4RH* 4-wire Horn/Strobe,High cd,Red PC4WH 4-wire Horn/Strobe,High cd,White P4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor Ceiling Strobes P4RHK 4-wire Horn/Strobe,High cd,Red,Outdoor SCR* Strobe,Standard cd,Red P4W* 4-wire Horn/Strobe,Standard cd,White SCRH* Strobe,High cd,Red P4WH* 4-wire Horn/Strobe,High cd,White SCRK Strobe,Standard cd,Red,Outdoor Wall Strobes SCRHK Strobe,High cd,Red,Outdoor SR*' Strobe,Standard cd,Red SCW*' Strobe,Standard cd,White SRH*' Strobe,High cd,Red 5CWH*1 Strobe,High cd,White SRK Strobe,Standard cd,Red,Outdoor Horns SRHK Strobe,High cd,Red,Outdoor HR Horn,Red SW* Strobe,Standard cd,White HRK Horn,Red,Outdoor SWH* Strobe,High cd,White HW Horn,White Ceiling Horn/Strobes Accessories PC2R* 2-wire Horn/Strobe,Standard cd,Red BBS-2 Back Box Skirt,Wall,Red PC2RH* 2-wire Horn/Strobe,High cd,Red BBSW-2 Back Box Skirt,Wall,White PC2RK 2-wire Horn/Strobe,Standard cd,Red,Outdoor BBSC-2 Back Box Skirt,Ceiling,Red PC2RHK 2-wire Horn/Strobe,High cd,Red,Outdoor BBSCW-2 Back Box Skirt,Ceiling,White Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2R-P t Add"-SP"to model number for"FUEGO"marking on cover,e.g.,P2R-SP #"Standard cd,"refers to strobes that include 15,15/75,30,75,95,110,and 1 15 candela settings."High cd refers to strobes that include 135,150,177,and 185 candela settings. All outdoor units ending in"K"include a weatherproof back box. n 1 SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 e rt m rc SENSOR. Phone:800-SENSOR2•Fax:630-377-6495 IJIIIIIIIIIIIIIililiillllilllllllllllllilllll NOTICE OF•COivnv>r�NCEMENT 2008135437 II IIIII IIII Ill! Permit No. 7 L1.0 Rept.: 1203770 Roe: 10.00 DS: 0.00 IT: 0.00 Property Identification No. �-2iy Z/—[`)[) .i U -- (jd bw—d d 3Q 09/17/08 Dpty Clerk ------- THE UNDERSIGNED hereby give informs you that the improvement will be made to certain real property,and in accordance with Section 713.13 of the Florida Statutes,the following information is provided in this NOTICE OF COMMENCEMENT. a-F-2eplot-k�ffs 1.Description of property(legal description:) Z ►t'- N o t P6 # QG- 27 PO r ad1' t '/2 f b-i a)Street Address: 9 25 6 . ,.General description of improvements: 'C..: x,.11O.I scv. c.. ✓'n., 3,.Owner Information n a)Name and address: r.fl:(( gga'J� LSI o/1 tQç 2 ept, rL;IBS/ F) b)Name and address of fee simple titleholder(if o er than owner) 3 S�1 c)Interest in property .4. tractor Information ,_ Q a)Name and address: S i l e Lure. T,nG. (p a-7 PrrdgteS5 L lce�t San foro _ I. 3 Y7 b)Telephone No.: -5 aa0 F x No.(Opt.) (-877- N8 7H 8 5.Surety Information a)Name and address: b)Amount of Bond: c)Telephone No.: Fax No.(Opt.) JED PITTMAN PASCO COUNTY CLERK 6.Lender 09/17/08 1g:28am 1 of 1 a)Name and address:. OR BK 7927 PG 28 Phone No. 7.Identity of person within the State of Florida designated by owner upon whom notices or other documents may be served: a)Name and address: b)Telephone,No.: Fax No.(Opt.) 8.In addition to himself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes: a)Name and address: •b)Telephone No.: Fax No..(Opt.) _ 9.Expiration date of Notice of Commencement(the expiration.date is one year from the date of recording.unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART I,SECTION 713.13,. FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PASCO gnature of wner's Authorized Officer/Director/Partner/Meneger PrintName . rr T 1 The foregoing instrument was acknowledged before me this �_day of ..{Q:a CL. ,2Q Q ,by y �l ok- . AUfr" as CST+�cK (type of authority,e.g.officer,trustee,attorney in fact)for . (name of party on behalf of whom instrument was ecuu'ted). Personally Known' OR Produced Identification ✓ Notary Signature Type of Identification Produced UCL' Name(print) a G Verification pursuant to Section 92.525,Florida Statutes.Under penalties of jerj,pry, read the foregoing and that the facts stated in it are true to the best of my knowledge and belief �g'"Y •., JAC UELIN OGE Commission DD 621833 - <r Expires December 12,2010 Bonded 11iiu Troy Fain Insurance 8005-7019 , Signature of Natural Person Signing Above FORMSMOCrvsd2007 STATE OF FLORIDA COUNTY OF PASCO THIS IS TO CERTIFY THAT THE FOREGOING IS A TRUE AND CORRECT COPY'OF THE DOCUMENT ON FILE OR OF PUBLIC RECORD iI D:-iI OFFICEITNESS MY HAND NID 13FF WAL, SEAL JS DAY OF JEIT1 �.IOCUIT CO - C t 'FPUiY CLERK DTK-120S15A Series Surge Protection 39kA/4 Series Connected Surge Protector ITEK General Product Specifications DITEK's 120S products protect power on 120V electrical circuits. The hybrid series design provides maximum critical load protection, with EMI/RFI filtering. Series installation eliminates the need to dedicate a circuit breaker for surge protection, while allowing installation flexibility. The 120S15A meets stringent government and military specs for control panel applications, and is suitable for use on any critical 15 Amp load. DTK-120S15A Application Features Line Diagram • Series design for fast response and best protection • Four-stage hybrid circuit design • User replaceable fusing for quick fault recovery • EMI/RFI filtering included [1 • Compact design fits a variety of equipment cabinets • Screw terminal connections with safety covers 2.227 • LEDs indicate protection status, ground presence, ground fault indication and fuse status 5070 Specifications Agency Approvals: Tested by Wyle Labs to UL1449, 2nd Edition 2007 criteria Service Voltage: 120VAC 0.190 MCOV: 150VAC 3. 73 Peak Surge Current: 39,000 Amps per phase Continuous Current: 15A EMl/RFl Attenuation: >56d6, 100kHz-100MHz Protection Modes: L-N, L-G, N-G Suppressed Voltage Rating: 500V 5.510 Temperature Range: -40°F - 185°F (-40°C-85°C) Dimensions: 6.00" x 3.58" x 2.32" (152mm x 91 mm x 59mm) Weight: .551b (.25kg) Housing: ABS ISO �R*� 9001-2000 �e Warranty: Ten Year Limited Warranty ® �.e. One DITEK Center 1-800-753-2345 Document:SPS-100047-001 Rev 3 9-07 1720 Starkey Road Technical Support: 1-888-472-6100 ©2007 DITEK Corp. Largo, FL 33771 www.ditekcoro.com Specification Subject to Change LVLP Series Voice, Data and Signaling Circuit Surge Protection ITEK General Product Specifications DITEK's Low Voltage Line Protector series of signal, a4 data and loop circuit surge protectors provide strong protection in a compact hard wire package. Applications DTK-4LVLPD include protection of 4-20mA current loops, alarm panel NAC, SLC and IDC loops, and burglar alarm panels. Models are available to protect 1, 2, 4 or 8 pairs. LVLAWG models can handle #14410 AWG wiring connections. DTK-LVLP Selection Guide Application Features • Series connection, parallel function adds no DTK-##LVL### resistance to loop circuits • Protect 1, 2, 4 or 8 pairs to match your configuration needs • Seven voltage levels available to protect all types of voice/data/loop applications SAD-Based: "Z" • "SCP" model provides automatically resetting Number of Pairs:: 1, 2, 4, 8 fusing and sneak current protection Wire Gauge: "P"for#22-16, "AWG" for#14-10 Sneak Current Protection: .15A current, "SCP" Voltage Level: D, X, LV, OPX, SPK, SGR, RUV Specifications (see table below for voltage ranges) Agency Approvals: UL497B, UL497A Connection Method: #22-#16 AWG screw terminals Example: DTK-4LVLPSCPD (LVLP), #14-#10 AWG screw terminals (LVLAWG) Example: DTK-8LVLAWGRUV Max Continuous Current: 5 Amps, 0.15 Amps (-SCP) Example: DTK-Z4LVLPLV Max Surge Current: 2,000 Amps per pair(6V-50V) Performance Data 9,000 Amps per pair(75V-130V) Protection Modes: Line-Ground (All) Model Service Clamp Operating Temperature: -40°F - 158°F (-40°C - 70°C) DTK-LVL# Voltage MCOV Voltage Maximum Humidity: 95% non-condensing D 0-6 V 8VDC 12V Dimensions: 1 LVL-4LVL— 1.6"H x 3.0"W x 1.6"D x 14V 18VDC 22V (41 mm x 76mm x 41 mm) LV 30 V 38VDC 47V 8LVL- 1.5"H x 4.8"W x 2.3"D (35mm x 122mm x 58mm) OPX 50 V 66VDC 82V Weight: 4oz (113g) SPK 75 V 102VDC 120V Housing: ABS SGR 95 V 127VDC 150V Warranty: Ten Year Limited Warranty Accessories: DIN Rail Kit— Part Number DTK-DRK RUV 130 V 175VDC 204V [so 9001-2000 `. 9L uS One DITEK Center 1-800-753-2345 Direct: 727-812-5000 Doc. Number:SPS-100030-001 Rev 2 9-07 1720 Starkey Road Technical Support: 1-888-472-6100 ©2007 DITEK Corp. Largo, FL 33771 www.ditekcorp.com Specification Subject to Change Global Project values: ' F a�-e n h y t �«�� Ze h rhills W WTF O rations Standby Hours Project ID 1110 Alarm Mins: 5 Prepared By J.Grocke,CET Deraft Fedor 1.2 Date:12/19/2007—� Voltage Drop Wamf Threshold%�0 Panel ID: IFP-100 I Model:IFP-1OO Max NAC Current 3.O Amps Location:I Maintenance Room 108 Volts: 24 VDC Max Panel Current:6.O Amps Ckt.# Circuit Name Q Current Draw Wire AWG Ohms Per Length(ft) Actual Volts ty %Drop Standby Alarm &Type 1OOO Ft. One-Way Ohms EOL IFP-1OO IFP-100 Main Control 1 O.2O6 O.358 SLC-DEV Addrsbl SLC Devices 7 O.OOO" 0.004 RA-1OO LCD Remote Annunc O.OOO `OOOO 5824 Serial/Parallel Module O.OOO 0000 RPS-1OOO Power Expander 0.000 0.0700 5865-4 LED Annunciator(4G) 0)100. "O.OOO 5865-3 LED Annunciator(3G) 0.000 O.OOO 588O LED Driver Module O.OOO" O.OOO Other Other SD-Duct Duct Hsg w/Relay 1 O.O35 0.075 5883 Relay Module O.OOO; 0.000 NAC#1 ' Notification Appl Circuit O.OOO " O.38O #14 Solid 2.52 500 2.52 18.94 7.16% NAC#2 Notification Appl Circuit O.OOO O.OOO #12 Solid 2.52 O.OO 2O.4O 0.00% NAC#3 Notification Appi Circuit O.OOO OOOO #12 Solid 1.59 O.OO 20.40 O.OO% NAC#4 Notification Appi Circuit 0.000 0.000 #12 Solid 1.59` O.OO 2O.4O O.OO% Total Standby Current(Anip O.241 1.O15 Total Alarm Current(Amps) Standby Time In Hour 24 O.O83 Alarm Time In Minutes 16O (5 Mins) Total Standby AH Reuirs 5.793 0.085 Total Alarm AH ReQuired Total Combined AH R 5.88 Command Shortcuts MuWply By The Derating Fact 1.2O Minimum Battery Am Hours Require 7.05 Configure Circuits j Print Page .IIIKIllIIThL!tulf1ur.1. Project Information Project Name: Zephyrhills WWTF Operations Project ID: 1110 Prepared By: J. Grocke, CET Date: 12/19/2007 Ckt. Number:NAC#1 Panel ID: IFP-100 Ckt. Name: Notification Appi Circuit I/O Usel Notification Appi Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 PC2415/ 15 0.000 0.079 0.000 0.316 4 PC2415/ 15 0.000 0.066 0.000 0.264 Unused 0.000 0.000 ' O.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.580 Ckt. Number: NAC#2 Panel ID: IFP-100 Ckt. Name: Notification Appi Circuit I/O Use: Notification Appi arcuit �1 Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 O.000 > 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.00O Totals 0.000 0.000 Ckt.Number:NAC#3 Panel ID: IFP-100 Ckt.Name: Notification Appl Circuit I/O Use: Notification Appi arcuit I l Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Configuration Project Information Project Name: Zephyrhills WWTF Operations Project ID: 1110 Prepared By: J. Grocke, CET Date: 12/19/2007 Ckt. Number: NAG#4 Panel ID: IFP-100 Ckt.Name: Notification Appi Circuit I/O Use: Notification Appi arcuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000` 0.000 0.000 ' 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 ' 0.000 0.000 0.000 0.000 Totals 0.000 0.000 SiteSecure,Inc. 627 Progress Way SiteSecure, Inc. Sanford,FL 32771 i Tel:407-328-5220 Englnn-ra & Int( ratur.: Toll Free:877-SITE-123 Fax:407-328-8346 www.SiteSecure.com FIRE ALARM SYSTEM FOR: CITY OF ZEPHYRHILLS, FLORIDA WASTEWATER TREATMENT FACILITIES EXPANSION OPERATIONS BUILDING SODIUM HYPOCHLORITE STORAGE CATALOG DATA SHEETS BATTERY CALCULATIONS APPROVED by Fire Marshal of Zephyrhilis with comm is provided with plan(s) Farenhyt Single Loop Analog/Addressable Fire Alarm Control System IFP-100 IFP-100 is an intelligent analog/addressable fire control panel.The basic IFP-100 system has a single SLC loop and four notification appliance ® MEA circuits that can be programmed for notification outputs or auxiliary power. IFP-100 also has a built-in dual line digital fire communicator, Form C 429-92-E Vol.XIV trouble relay, and two programmable Form C relays.The firmware has powerful features, such as detector sensitivity, day/night thresholds, drift compensation and pre-trouble maintenance alert. Ip IFP-100 supports a variety of other devices that can be added to the system such as RA-100 remote annunciator, 5824 serial/parallel printer interface module(for printing system reports), and 5496 intelligent power module, and Hochiki or Intelligent Device Protocol (IDP)devices. Features • Built-in support for up to127 Hochiki devices or 99 IDP detectors and 99 IDP modules • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator for remote reporting of system activity and system programming • Central station reporting by point or by zone • Jumpstart®auto-programming • Supports Class B(Style 4)and Class A(Style 6 or Style 7)configuration for SLC • Distributed, intelligent power IFP-100 • Built-in synchronization for AMSECO, Gentex®, Faraday, System • 6 amp power supply and maximum charging Sensor®, and Wheelock®appliances capacity of 35 amp hours (An additional • Sensor sensitivity settings and day/night sensitivity setting cabinet enclosure is required for batteries in excess of 18 amp hours) • Automatic drift compensation • • Notification circuits configurable as 2 Class A(Style Z , 4 Class B (Style from ntegratpo dead front panel protects operator 9 ( tY ) ( Y exposure to electrical components Y), or auxiliary power for resettable, constant, or door holder power • The FACP enclosure features a • Built-in annunciator with a backlit 80-character LCD displayannunciator ciato lass® r viewing window to protect annunciator • RS-485 bus provides communication to system accessories • Programmable to automatically display oldest • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC event first or display tally of system events • Two built-in Form C programmable relays rated at 2.5 amps at 27.4 VDC • Acknowledge function allows operator to keep track of event status • SLC device locator can be used to locate a single or multiple devices on a SLC loop • Programmable date setting for Daylight Saving Time • System automatically performs detector sensitivity test • 13 preset notification cadence patterns (including ANSI 3.41)and four Installation user programmable patterns • Built-in RS-232 and USB interface for programming The IFP-100 can be surface or flush mounted. • Upload or download programming, event history, or detector status onsite or from a remote location using a PC and 5650/5651 Silent Knight Software Suite(SKSS) • Improvements in SKSS deliver five times faster upload/downloads • Non volatile event history stores up to 1000 events • 125 Software zones and 125 output groups SILENT 7550 Meridian Circle Maple Grove,Mn 55369-4927 I P/N 350388 Rev E 04/21/06 KNIGHT 763-493-6455 Copyright®2006 Silent Knight 1-800-328-0103 Jumpstart>is a Registered Trademark of Fax:763-493-7475 Silent Knight by Honeywell http://www.farenhyt.com Compatibility Telephone The IFP-100 SLC supports multiple device types of the same Requirements: FCC Part 15&Part 68 approved protocol: Jack: RJ31X(two required) • Hochiki Approvals • IDP NFPA 13, NFPA 15, NFPA 16, NFPA 70, & You cannot mix Hochiki and IDP devices on a FACP. However, NFPA 72: Central Station; Remote Signalling; Local Protective any combination of addressable devices of the same protocol Signalling Systems;Auxiliary Protected Premises Unit; &Water can be used on the IFP-100. Deluge Releasing Service.Suitable for automatic, manual, waterflow, sprinkler supervisory(DACT non-coded)signalling See Hochiki Devices specification sheet(PN 350360)and IDP Device Protocol Devices specfication sheet(PN 350361)for services. more information. Other Approvals: UL Listed; CSFM 7170-0559: 142; MEA 429-92-E Vol.XIV Specifications Ordering Information Physical Flush Mount Dimensions: 14.5"W x 24.75"H x 3.5"D IFP 100 Intelligent Fire Alarm Control Panel. (36.8 W x 62.9 H x 8.73 D cm) SBUS Accessories Overall Dimensions: 16"W x 26.4"H x 4.65"D RA-100 Remote Annunciator. Same operation and (40.6 W x 67 H x 11.8 D cm) similar appearance to FACP annunciator. Weight: 28 lbs. (12.8 kg) RA-1000R Remote Annunciator. Four line LCD annunciator with 20 characters per line. Color: Red Red. Environmental RA-1000 Remote Annunciator. Four line LCD Operating Temperature: 32°F- 120°F (0°C—49°C) annunciator with 20 characters per line. Gray. Humidity: 10%—93% non-condensing RPS-1000 Intelligent Power Module. Electrical 5496 Intelligent Power Module. Primary AC: 120 VRMS @ 50/60 Hz, 2.5A 5824 Serial/Parallel Printer Interface Module. Total Accessory Load:6A @ 27.4 VDC power-limited 5880 LED I/O Module. Standby Current: 170 mA 5865-3&5865-4 LED Fire Annunciators. Alarm Current: 325 mA 5883 Relay Interface Board. Battery Charging Capacity: 7 to 35 AH Hochiki and IDP Devices Battery Size: 18 AH max. allowed in control panel cabinet. See the specification sheets listed below for a complete listing Larger capacity batteries can be housed in RBB accessory of the Hochiki and IDP devices. cabinet. 350360 Hochiki Devices Specification Sheet. Notification Appliance Circuits 350361 Intelligent Device Protocol Devices Four circuits that can be programmed individually as: Specification Sheet. Notification Circuits: 3A per circuit @ 27.4 VDC, power-limited Miscellaneous Accessories Auxiliary Power Circuits: 3A per circuit @ 27.4 VDC, 5650/5651 Silent Knight Software Suite. Provides power-limited programming, upload/download, and Indicator Lights event reporting. Alarm(Red): Flashes when in alarm;solid when alarm silenced 5670 Silent Knight Software Suite. Provides facility monitoring. Supervisory (Yellow): Flashes when a supervisory condition exists; solid when supervisory silenced RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit Trouble(Yellow): Flashes when a trouble condition exists; solid into FACP cabinet. Dimensions: when trouble silenced 16"W x 10" H x 6" D Silenced (Yellow): Solid when an alarm,trouble or supervisory (406 mm W x 254 mm H x 152 mm D) condition has been silenced but not yet cleared Power(Green): Flashes for AC failure; solid when power systems are normal i' This document is not intended to be used for installation purposes.We try to keep our f product information up-to-date and accurate.We cannot cover all specific applications KNIGHT or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight 7550 Meridian Circle Suite 100, Maple 1 Grove,Mn 55369-4927.Phone:(800)328-0103, Fax:(763)493-6475. by Honoy''. e Made in the U.S.A I'°I Farenhyt Addressable Pull Station Model SD500-PS and SDSOO-PSSDA Addressable Pull Station The SD500-PS is a single action addressable fire pull station, and ,'ry if}i ( UM EA the SD500-PSDA is a dual action addressable fire pull station. The SD500-PS/PSDA feature rugged metal construction. A terminal , 429-92-E Vol.9 strip on back of the pull station allows interconnection of the pull station to the SLC loop of a Silent Knight analog/addressable fire alarm control panel. The SD500-PS/PSDA is designed for indoor use in non-explosive environments. The normally open initiating point contacts are gold-plated to avoid risk of corrosion. The SD500-PS/PSDA has been tested by UL for compliance to the requirements of the Americans with Disabilities ACT (ADA). Features • UL Listed • CSFM listed • ADA compliant # • Key reset (Same key as Silent Knight enclosures) • Surface mount back box available • Terminals - accept up to 14 gauge wire 1 A • Extremely easy to operate • Corrosion-resistant gold-plated contacts. • Reflective label makes it easier to locate in low light 0 The SO500-PS single action pull stations are operated by a pull on the front pull cover of the station. The SD500-PSDA dual action pull SDSOO-PS stations are operated by lifting up an access plate and then pulling forward on the front cover of the pull station. A plunger switch, Spuffic bons wired to a self contained addressable module, is released as the pull station opens to initiate the alarm. Once operated, the cover Operating Voltage: 24VDC hangs down and can be seen up to 100 feet away. The pull station Standby Current. .55mA is reset by returning the front cover to the normal upright position Alarm Current: .55mA and relocking the station with a reset key. The reset keys are the Ambient same keys used on Silent Knight enclosures. Temperature: 32°F to 120°F The SD500-PS/PSDA includes a status LED which blinks, indicating (0°C to 49°C) that the addressable module is communicating with the loop. The Mounting: Single gang box status LED lights continuously during an alarm. A dip switch on the Optional Red Surface addressable module is used to set the unique address. Mount Box PS-SMBB Dual Action Conversion Kit SD500-LK Included with SD500- PSDA or it can be ordered separately and used to convert SD500-PS to SD500-PSDAs (See illustration on r 7550 Meridian Circle back page.) S I I. _N�I Maple Grove,Mn 55369-4927 i, 763-493-6455 R\ I(7 TI' 1-800-328-0103 P/N 350254,09/02 Fax:763-493-7475 Copyright©2002 Silent Knight http://www.farenhyt.com rrithu SLC Wiring Dimensions R#r r F SD500-U(Installation D SiLENT 7550 Meridian Circle, Maple Grove, MN 55369-4927 1-800-446-6444 or in Minnesota 763-493-6435 KNIGHT FAX: 763-493-6475 World Wide Web: http://www.farenhyt.com Made in the U.S.A. Farenhyt Duct m detector housing with Relay module(SD505-AHDR)and Remote Test Switch (SD505-DTS) SO505-ADHR I DTS Duct Detector Housing with Relay Module and Remote Test Switch The SD505-ADHR analog addressable duct smoke detector with built-in relay module detects products of combustion present in air moving through an HVAC system.The SD505-ADHR is compatible with the SD505-DTS , which provides remote annuncaition and testing capabilities for the SD505-ADHR. The SD505-ADHR is a heavy duty metal housing with a pre- installed detector base. When smoke is detected in a duct, the unit communicates the condition to the FACP. The panel, in turn, depending on programming, turns off fans, blowers, and other devices. --."- - -- The SD505-ADHR is designed to be used with the SD505-APS Detector. Photoelectric Smoke Detector and SD505-AIS Ionization Smoke Features • Two-wire connection to SLC • LED alarm indication and communication on sensor head • Rugged steel backbox with clear plastic cover • Installation template included • Large terminal connection screws • Interchangeable "plug-in" photoelectric or ionization heads • UL listed a s • Alarm Relay rated at 120/240 VAC @ 10A to control HVAC SD505-ADHR power. • Built-in Trouble Relay SD505-ADHR Alarm: 75 mA @ 24 VDC Standby: 35 mA @ 24 VDC Specifications SLC Current: .082 mA Included Parts: Alarm Relay: 10A @ 120/240VAC Metal housing with 7.5"exhaust tube 10A@ 24 VDC SD505-4AB detector base Trouble Relay: 2.5 A @ 30VDC Installation template Air Velocity: 500-4000 fpm SD505-DTS 4 mounting screws (SD505-APS) 5D505-DTS Specifications Accessories: 300-4000 fpm (SD505-AIS) Dimensions: Photoelectric Smoke Det.SD505-APS Height: 4.5" Ionization Smoke Det.SD505-AIS Sensitivity: 1.1 (SD505-APS) Width: 2.75" Sampling tube for 6"to 2.5'duct width 0.8(SD505-AIS) Depth: 1-5/8" STS-2.5 Ambient Color: Red Temperature: 3 °F to 100°F Sampling tube for 2.5'to 5.0'duct 2 width STS-5.0 (0 C to 37 C) Humidity: 10 to 85%RH Sampling tube for 5.0'to 10.0'duct width STS-10.0 Dimensions: 10"H x 8.25"W x 2.25"D Operating Voltage: 24VDCNDC, 120/240 VAC Color: Gray Current: S 7550 Meridian Circle r SILENT Maple Grove,Mn 55369-4927 KNIGHT 763-493-6455 P/N 350326 Rev. B, 02/04 1-800-328-0103 Copyright @ 2004 Silent Knight Fax:763-493-6475 by Honey'P:ei! www.farenhyt.com FACP/5815XL `� -sql FACP/5815XL Connection Connection tint{'C1�'f _ _ t Class B (Style 4) Class A(Style 6) E DTS connections SILENT This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific applications I<N IC HT or anticipate all requirements.All specifications are subject to change without notice For more information,contact Silent Knight 7550 Meridian Circle Suite 100,Maple Y Hfy } Grove,Mn 55369-4927.Phone:(800)328-0103.Fax:(763)493-6475. t l, ;2i1 Made in the U.S.A F a r e n h y t Analog/Addressable Photoelectric Smoke Ntector SD505-APS In addition to accurately detecting a smoldering fire, each SD505- APS photoelectric detector has a unique address, which is recognized by the FACP. The SD505-APS compensates automatically for contamination in M EA F the environment. Detector calibration testing is simple—even from a remote site. The SD505-APS offers a low profile installation and uses the Model SD505-6AB base, compatible with other detectors 429-92-E, Vol. 9 APPROVED in the series, allowing for complete application and placement flexibility. Like other Farenhyt smoke detectors, the SD505-APS offers easy installation, stable operation, RF/transient protection, and vandal-resistant locking. (� ay . Features ,.i • Low profile, 2 inches, including base • Simple and reliable addressing without mechanical switches —' • Automatic compensation for sensor contamination • Built-in fire test feature • Simple detector calibration testing through the control panel or remotely through a WindowsTM based computer. (WindowsTM software required for remote testing.) # • Vandal-resistance locking features • Field cleanable • UL listed, meets NFPA 72 Ch 7 requirements • CSFM Approved • MEA Approved • FM Approved Specifications Operating Voltage: 17-41 VDC Current Consumption: Standby: .55 mA Alarm: .55 mA Operating Temperature: 32°F to 120°F (0'C to 49°C) Relative Humidity: 85% noncondensing Sensitivity: 0.88% - 3.56% FT Air Velocity: 0 - 300 FPM 7550 Meridian Circle SILENT Maple Grove,MN 55369-4927 KNIGHT 1-800-328-0103 763-493-6435(in Minnesota) P/N 350226 Rev C, 05/16/05 Fax:763-493-6475 Copyright©2005 Silent Knight http://www.farenhyt.com FACP/5815XL Terminal 5 or 6 6" Base 1 'rI \ / \ -- P/N SD505-6AB s„c,• ou'r €.c tv jt Terminal 1 or 2 Wiring to SLC Diameter=5-15,15• Diameter=3-15/16" — GI. Height=2 inches, including base i ( SRfi.14T Model SD505-APS Model SD505-6AB (Top View) Detector Base (Top View) This document is not intended to be used for installation purposes.We to keep our SILENT P Ptry 4� �a KNIGHT product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight 7550 Meridian Circle Suite 100.Maple by HDrev,, .e Grove.Mn 55369-4927 Phone:(800)328-0103, Fax:(763)493-6475. Made in the U.S.A. Fa r e fl ti 3( t Dry Contact Input Module SD500-AIM & SD500-MIM The SD500-AIM and SD500-MIM are addressable input modules for UL MEA use with the Farenhyt fire alarm control panels (FACPs). The 429-92-E Vol.IX SD500-AIM addressable input module mounts to a 4"-square box. The SD500-MIM mini input module fits inside a single gang box. Both input modules are designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. ©" These modules are supervised, single input contact monitors. Using an EOL resistor, they monitor for alarm contact closures and for open circuit wiring fault conditions. If a fault occurs in the wiring, the $D500-AIM module alerts the FACP. Each addressable input module is programmed with a unique signal line circuit (SLC) loop address. Features • Single contact monitor -. • Support for Class A(Style 6 & Style 7) or Class B (Style 4) wiring • Attractive ivory cover plate with the SD500-AIM sooa-aalM • Small and lightweight size allows for flexible mounting options with the SD500-MIM Compatibility • DIP switch programmable for fast installation The SD500-AIM and SD500-MIM are • Up to 2500 ft wiring distance from either input module to contact compatible with the following FACPs: • Use up to 14 gauge wire • IFP-1000 Intelligent Fire Panel • UL listed IFP-100 Intelligent Fire Panel Installation • IFP-50 Intelligent Fire Panel The SD500-AIM mounts in a 4" square or double gang junction box The SD-500MIM mounts in a single gang junction box directly behind the monitored device. Its small size and light weight allow it to be installed without rigid mounting requirements. SIiEVT 7550 Meridian Circle � 7 Maple Grove,Mn 55369-4927 K 1 G HT 763-493-6455 P/N 350232 Rev C,05/04/06 1-800-328-0103 Copyright©2006 Silent Knight Fax:763-493-6475 by Ho nee;`t24i www.farenhyt.com To:-Liu gp� . Specifications Environmental Operating Temperature: 32°F- 120°F(0°C-49°C) Physical SD500-AIM Humidity: 10%—93% non-condensing Width: 4.9"(12.4 cm) Approvals Height: 4.9"(12.4 cm) NFPA 72 Depth: 1"(2.5 cm) Shipping Weight: 3.6 oz(120.1 g) UL Listed SD500-MIM CSFM 7300-0559: 132; Width: 1.5"(3.8 cm) Height: 2.5"(6.4 cm) MEA 429-92-E Vol IX Depth: 0.7"(1.8 cm) FM approved for use with IFP-1000 Shipping Weight: 1.6 oz(45-4 g) Electrical Ordering Information Standby Current: 0.55 mA SD500-AIM Addressable Input Module Alarm Current: 23 mA max for one device; 46 mA max for two SD500-MIM Addressable Mini Input Module devices; 0.55 mA for each additional device Line Resistance: 50O max SILENT This document is not intended to be used for installation purposes.We try to keep our r _ product information up-to-date and accurate.We cannot cover all specific applications 44 KI\I �FIT or anticipate all requirements.All specifications are subject to change without notice For more information,contact Silent Knight 7550 Meridian Circle Suite 100, Maple by Syr V r.Ec Grove,Mn 55369-4927 Phone:(800)328-0103,Fax:(763)493-6475. Made in the U.S.A ae ri I' i t Two Form C contacts,2.OA @ 30 VDC or.6A @ 120 VAC SD500-ARM Addressable Relay(Nodule The SD500-ARM is an addressable device that adds two M EA Form C contacts to the Farenhyt system. The contacts are F M rated at 2.0 amps @ 30 VDC or .6 amp @ 120 VAC. The 429-92-E, Vol. 9 SD500-ARM allows you to control a wide variety of normally APPROVED open and normally closed applications, including elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is addressable, these applica- tions can be located at any point in the signaling line circuit. Features • Two sets of Form C contacts. (Double pull/Double Throw relays) • Contacts are rated at 2A @ 30 VDC or .6A @ 120 VAC. • Up to 127 relays can be used on each SLC loop. • Relay programming is completely flexible—can be mapped to zone conditions. • Polling LED visible through cover plate. • UL listed, complies with NFPA 72. • CSFM approved Qc•6Q • MEA approved • FM approved Specifications Contact Rating: Form C 2A @ 30 VDC or ,6A @ 120 VAC Standby Current: .55 mA Alarm Current: .55 mA Operating Temperature: 32°F to 120°F (0°C to 49°C) Dimensions: 4-7/8"H x 4-7/8"W x 1"D Mounting: 4-square Compatible Control Panels IFP-1000 IFP-100 7550 Meridian Circle SI LEINi T Maple Grove,MN 55369-4927 1-800-328-0103 K1\KNIGHT 763-493-6455(in Minnesota) PIN 350219. 12/01 Fax:763-493-6475 Copyright©2001 Silent Knight http://wNw.farenhyt.com FRONT VIEW 0 O 0 O O O O iaarr �vr II a 0 00 4-7/8" 1/4" Dimensions �— , x� s. W.C OI tN Contact 1 Contact 2 SD500-ARM Wiring SftF 7550 Meridian Circle, Maple Grove, MN 55369-4927 Ll _ 1 1-800-446-6444 or in Minnesota 763-493-6435 K N I G li I' FAX: 763-493-6475 World Wide Web: http://www.farenhyt.com Made in the U.SA. SYSTEM LL>u r. . Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlert'Advance selectable-output horns,strobes, and horn/strobes are rich with features guaranteed to j� cut installation times and maximize profits. Sr ECTRA1Crt The SpectrAlert Advance series of notification appliances is Features designed to simplify installations,with features such as plug in Electrically compatible with existing SpectrAlert products designs,instant feedback messages to ensure correct installation of •Automatic selection of 1 2 or 24 volt opera-ion at 15 and 15/75 individual devices,and 11 field-selectable candela settings for wall candela and ceiling strobes and horn/strobes. •Plug-in design When installing Advance products,first attach a universal mounting •Field selectable candela settings on wall and ceiling units:15,15/75, plate to a four-inch square,four-inch octagon or double-gang 30,75,95,110,1 15,135,150,177,185 junction box.The two-wire mounting plate attaches to a single-gang •Same mounting plate for wall-and ceiling-mount units junction box. •Shorting spring on mounting plate for continuity check before installation Next,connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. •Tamper resistant construction •Outdoor wall and ceiling products rated from-40°F to 151°F Finally,attach the horn,strobe or horn/strobe to the mounting plate .Design allows minimal intrusion into the back box by inserting the product's tabs in the mounting plate's grooves.The .Horn rated at 88+dhA at 16 volts device will rotate into position,locking the product's pins into the mounting plate's terminals.The device will temporarily hold in place •Rotary switch for horn tone and three volume selections with a catch until it is secured with a captured mounting screw. •Outdoor products UL listed to UL 1638(strobe)and UL 464(horn) outdoor requirements The SpectrAlert Advance series includes outdoor notification •Outdoor products rainproof per UL 50 IINEMA 3R) appliances.Outdoor strobes and horn/strobes(two wire and four wire)are available for wall or ceiling.Outdoor horns are available for •Compatible with iMDL sync module wall only.All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenl reit in wet or dry anpiications Agency Listings srciuurc ® F MEA ®� 3 LISTED APPROVED approved SpectrAlert Advance Specifications General SpectrAlert Advance horns,strobes and horn/strobes shall mourn to a standard 4 x 4 x 1½-inch back box,4-inch octagon back box or double-gang back box.Tvvo-wire products_hall also mount to a single-gang 2 x 4 x I%s-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the Sync-Circuit .Module accessory,shall be poweed from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts,When used with the Sync.•C rr ct Module, i 0-volt rated notification appliance circu1t outputs shall operate between nine and 175 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts indoor SpectrAlert Advance products shall operate between 32 and 120 decrees Fahrenheit from a regulated DC,or full-vvave rectified unfiltered power supply.Strobes and horn/strobes shall have field-selectable candela settings including 15.t 5/75.30 75,95,110,1 15,135,150,177,185. Strcba the strobe shall he 3 System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service.The strove shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's cnt,ro operating voltage range.The strobe light shall consist of a xenon flash tubc and associated lens/reflector systemn Horn/Strobe Combrnat,,cn The horn/strobe shall he a System Sensor SpectrAlert Advance Model listed to lJL 1971 and IJL 464 and shall he approved for fire protective service Tire horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a nor-temporal(continuous) pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns,strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit.The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries, Synchronizat;c rt Module The module shall be a System Sensor Syn Cir_uit model MDL listed to UL 464 and shall be approved for fire protective service The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn/strobe models over a single pair of wires.The module shall mount to a 4'Yie x 4°5',c x 21/winch back box.The module shall also control two Style Y(class B)circuits or one Style Z (class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120F(0°C to 49°Q K Series Operating Temperature —40°F to 151°F(-40°C to 66°C) Humidity Range 10 to 93%non-condensing(indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Range' 8 to 17.5 V(12V nominal)or 16 to 33 V(24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions(including lens) 6.8 diameter x 2.5-high(173 mm diameter x 64 min high) Wall mount dimensions(including lens` 5.61 x 4.7-W x 2.5-D(142 mm Lx 11';min VV x 64 rnm D) Horn dimensions 5.61 x 4.7W x 1.3'D(142 mm Lx i 19 mm W x 33 rnm D) Wall-mount back box skirt dimensions(BBS-2,BBSW-2) 5.91 x 5.0"W x 2.2D(151 mm Lx 128 mm W x 56 mm D) Ceiling-mount back box skirt dimensions(BBSC-2,BBSC}VJ-2) 7.1 diameter x 2.25 high(180 rnm diameter x 57 rnm high) Wail mountweatherproof back box dimensions(SA-W88) 5.71 x 5.1W x J.0"D(145 mm 1 x 137 mm W x 51 rnm Dl Ceiling-mount weatherproof back box dimensions(SA-WBBC) 7.1 diameter x 2.0"high(120 mm diameter x St min highl Motes: 1 cull Wage Rectified(FVVR)voltage is a non-regulated,time varying power source that is used an some power supply and panel outputs 2.25 PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd UL Current Draw Data 8-17.5 Volts 16-33 Volts 8-175 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern d6 DC FWR DC FWR Standard 15* 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75° 142 148 77 81 Temporal Medium 44 49 58 69 30* NA NA 94 96 Temporal Low 38 44 44 48 75* NA NA 158 133 Non-temporal High 57 56 69 75 95* NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 L11! ii 8-173 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temooral High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 III 16-33 Volts 16-33 Volts DClnput 135 150 177 185 FWRInput 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temooral Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal.Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed candeia ratings must be reduced in accordance with this table. 8-173 16-33 24 Volt Nominal ,. Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at-40°F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32 2 Temporal Medium 74 74 80 80 86 86 96 96 30 -- 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non-temporal High 82 82 88 88 93 92 100 100 95 70 5 Non-temporal Medium 78 78 85 85 90 90 98 98 110 110 o Non-temporal Low 75 75 81 el 88 84 96 92 115 115 7' Coded High 82 82 88 88 93 92 101 101 135 135 8' Coded Medium 78 78 85 85 90 90 97 98 150 150 9- Coded Low 75 75 81 81 88 85 96 92 177 177 '3emngs 7,8,and 9 are not availabie on 2-wire horn/strobe 185 185 SpectrAlert Advance Dimensions • r-4.7" 2.5- Dia. T 2.5' Wail-mount hero/strobes Ceiling-mount horn/strobes 7.1' 2.25 11 2.0' Dia. 5.05'- 2.231 Dia.O o o O o ® o O v 0 C O Wall back bu..skirt Ceiling back box s'k:rx Wall weatherproof hack box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Wall Horn/Strobes Ceiling Horn/Strobes(cont'd.) P2R*' 2-wire Horn/Strobe,Standard cdr,Red PC2W*' 2-wire Horn/Strobe,Standard cd,1//hite P2RH* 2-wire Horn/Strobe,High cd,Red PC2WH*i 2-wire Horn/Strobe,High cd,White P2RK* 2-wire Horn/Strobe,Standard cd,Red,Outdoor PC4R 4-wire Horn/Strobe,Standard cd,Red P2RHK* 2-wire Horn/Strobe,High cd,Red,Outdoor PC4RH 4-wire Horn/Strobe,High cd,Red P2W' 2-wire Horn/Strobe,Standard cd,White PC4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor P2WH' 2-wire Horn/Strobe,High cd,White PC4RHK 4-wire Horn/Strobe,High cd,Red,Outdoor P4R 4-wire Horn/Strobe,Standard cd,Red PC4W 4-wire Horn/Strobe,Standard cd,White P4RH' 4-wire Horn/Strobe,High cd,Red PC4WH 4-wire Horn/Strobe,High cd,White P4RK 4-wire Horn/Strobe,Standard cd,Red,Outdoor Ceiling Strobes P4RHK 4-wire Horn/Strobe,High cd,Red,Outdoor SCR' Strobe,Standard cd,Red P4W' 4-wire Horn/Strobe,Standard cd,White SCRH' Strobe,High cd,Red P4WH' 4-wire Horn/Strobe,High cd,White SCRK Strobe,Standard cd,Red,Outdoor Wail Strobes SCRHK Strobe,High cd,Red,Outdoor SR" Strobe,Standard cd,Red SCW" Strobe,Standard cd,White SRH'' Strobe,High cd,Red SCWH*i Strobe,High cd,White SRK Strobe,Standard cd,Red,Outdoor Horns SRHK Strobe,High cd,Red,Outdoor HR Horn,Red SW' Strobe,Standard cd,White HRK Horn,Red,Outdoor SWH* Strobe,High cd,White HW Horn,White Ceiling Horn/Strobes Accessories PC2R' 2-wire Horn/Strobe,Standard cd,Red BBS-2 Back Box Skirt,Wall,Red PC2RH* 2-wire Horn/Strobe,Higl-i Cd,Red BBSW-2 Back Box Skirt,Wall,White PC2RK 2-wire Horn/Strobe,Standard cd,Red,Outdoor BBSC-2 Back Box Skirt,Ceiling,Red PC2RHK 2-wire Horn/Strobe,High cd,Red,Outdoor BBSCW-2 Back Box Skirt,Ceiling,White Notes: 'Add'-P"to moue)number for plain housing(no"FIRE"marking on cover),e.g.P2R-P t Add SP'to model number for"FUECO"marking on cover,e.g.,P2R-SP r Standard cd"refers to strobes that include 15,15/75,30,75,95.1 10,and 1 15_andela set*ii)gs High cd;refers to strobes that include 135,150,177,and 185 candela settings. All outdoor units ending in'K"include a weatherproof back box. 3825 Ohio Avenue St Charles,IL 60174 �`\ sevso 4 Phone S00-SENSOR2•Fax 630-377-5495 DTK-120S15A Series Surge Protection 39kA/qh Series Connected Surge Protector i. DITEK General Product Specifications DITEK's 120S products protect •power on 120V electrical circuits. The hybrid series �► design provides maximum critical load a1u1 protection, with EMI/RFI filtering. Series installation eliminates the need to dedicate a f circuit breaker for surge protection, while allowing installation flexibility. The 120S15A meets stringent government and military specs for control panel applications, and is suitable for use on any critical 15 Amp load. DTK-120S15A Application Features Line Diagram • Series design for fast response and best protection • Four-stage hybrid circuit design • User replaceable fusing for quick fault recovery • EMI/RFI filtering included • Compact design fits a variety of equipment cabinets • Screw terminal connections with safety covers = • LEDs indicate protection status, ground presence, f' ground fault indication and fuse status .. Specifications Agency Approvals: Tested by Wyle Labs to jQ . y � UL1449, 2nd Edition 2007 criteria f I # Service Voltage: 120VAC r MCOV: 150VAC Peak Surge Current: 39,000 Amps per phase r£ Continuous Current: 15A EMI/RFI Attenuation: >56d6, 100kHz-100MHz Protection Modes: L-N, L-G, N-G O Suppressed Voltage Rating: 500V Temperature Range: -40°F- 185°F (-40°C-85°C) Dimensions: 6.00" x 3.58" x 2.32" (152mm x 91 mm x 59mm) Weight: .551b (.25kg) Housing: ABS ISO ,RT, Warranty: Ten Year Limited Warranty 9001-2000 (WY�,.d One DITEK Center 1-800-753-2345 Document:SPS-100047-001 Rev 3 9-07 1720 Starkey Road Technical Support: 1-888-472-6100 @2007 DITEK Corp. Largo, FL 33771 wwv.ditekcorrr)cc)m Specification Subject to Change LVLP Series Voice, Data and Signaling Circuit Surge Protection /DITE\K . General Product Specifications DITEK's Low Voltage Line Protector series of signal, data and loop circuit surge protectors provide strong protection in a compact hard wire package. Applications DTK-4LVLPD include protection of 4-20mA current loops, alarm panel NAC, SLC and IDC loops, and burglar alarm panels. Models are available to protect 1, 2, 4 or 8 pairs. t' LVLAWG models can handle #14410 AWG wiring connections. . DTK-LVLP Selection Guide Application Features • Series connection, parallel function adds no DTK-##LVL### resistance to loop circuits • Protect 1, 2, 4 or 8 pairs to match your configuration needs • Seven voltage levels available to protect all types of voice/data/loop applications SAD-Based: "Z" • "SCP" model provides automatically resetting Number of Pairs:: 1, 2, 4, 8 fusing and sneak current protection Wire Gauge: "P"for#22-16, "AWG" for#14-10 Sneak Current Protection: .15A current, "SCP" Voltage Level: D, X, LV, OPX, SPK, SGR, RUV Specifications (see table below for voltage ranges) Agency Approvals: UL497B, UL497A Connection Method: #22416 AWG screw terminals Example: DTK-4LVLPSCPD (LVLP), #14-#10 AWG screw terminals (LVLAWG) Example: DTK-8LVLAWGRUV Max Continuous Current: 5 Amps, 0.15 Amps (-SCP) Example: DTK-Z4LVLPLV Max Surge Current: 2,000 Amps per pair(6V-50V) Performance Data 9,000 Amps per pair(75V-130V) Protection Modes: Line-Ground (All) Model Service Clamp Operating Temperature: -40°F - 158°F (-40°C - 70°C) DTK-LVL# Voltage MCOV Voltage Maximum Humidity: 95% non-condensing D 0-6 V 8VDC 12V Dimensions: 1 LVL-4LVL— 1.6"H x 3.0"W x 1.6"D X 14 V 18VDC 22V (41 mm x 76mm x 41 mm) 8LVL— 1.5"H x 4.8"W x 2.3"D LV 30 V 38VDC 47V (35mm x 122mm x 58mm) OPX 50 V 66VDC 82V Weight: 4oz (113g) SPK 75 V 102VDC 120V Housing: ABS SGR 95 V 127VDC 150V Warranty: Ten Year Limited Warranty Accessories: DIN Rail Kit— Part Number DTK-DRK RUV 130 V 175VDC 204V 1St) 9001.2001) C U� u5 One DITEK Center 1-800-753-2345 Direct:727-812-5000 Doc. Number:SPS-100030-001 Rev 2 9-07 1720 Starkey Road Technical Support: 1-888-472-6100 ©2007 DITEK Corp. Largo, FL 33771 wwv.ditekcoro.ccm Specification Subject to Change Global Project Values: Fa r e n h t Name Ze h chills WWTF O rations Standby Hours 24 yProject ID:1110 Alarm Mins:05 Prepared By J.Grocke,CET Derailing Factor 1.2 Date: 12/19/2007 Voltage Drop Warning Threshold%: 20 Panel ID: IFP-100 t Model:IFP-100 Max NAC Current: 3.0 Amps Location:IMaintenance Room 108 I Volts: 24 VDC Max Panel Current 6.0 Amps CkL# Circuit Name oty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm &Type 1000 Ft. One-Way Ohms EOL IFP-100 IFP-100 Main Control 1 0.206 0.356 SLC-DEV Addrsbl SLC Devices 7 0.000 0.004 RA-100 LCD Remote Annunc 0.000 0.000 5824 Serial/Parallel Module 0.000 0.000 RPS-1000 Power Expander 0.000 0.000 5865-4 LED Annunciator(4G) 0.000 0.000 5865-3 LED Annunciator(3G) 0.000 0.000 5880 LED Driver Module 0.000 0.000 Other Other SD-Duct Duct Hsg w/Relay 1 0.035 0.075 5883 Relay Module 0.000 0.000 NAC#1 Notification Appi Circuit 0.000 0.580 #14 Solid 2.52 500 2.52 18.9447.161% NAC#2 Notification Appi Circuit 0.000 0.000 #12 Solid 2.52 0.00 20.40 NAC#3 Notification Appi Circuit 0.000 0.000 #12 Solid 1.59 0.00 20.4NAC#4 Notfication I Circuit 0.000 0.000 #12 Solid 1.59 0.00 20.40 Total Standby Current(Amps 0.241 1.015 Total Alarm Current(Amps) Standby Time In How 24 0.083 Alarm Time In Minutes/60 (5 Mins) Total Standby AH Reauire 5.793 0.085 Total Alarm AH Reouired Total Combined AH Require 5.88 Command Shortcuts Multiply By The Derating Facti 1.20 Minimum Battery Am Hours Requirt 7.05 Configure Circuits Print Page `• • • • Project Information Project Name: Zephyrhills WWTF Operations Project ID: 1110 Prepared By: J. Grocke, CET Date: 12/19/2007 Ckt. Number: NAC#1 Panel ID: IFP-100 Ckt. Name: Notification Appl Circuit I/O Use Notification Appl Circuit • Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 PC2415/ 15 0.000 0.079 0.000 0.316 4 PC2415/ 15 0.000 0.066 0.000 0.264 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.580 Ckt. Number: NAC#2 Panel ID: IFP-100 Ckt. Name: Notification Appl Circuit I/O Use: Notification App!Circuit Qty Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt. Number: NAC#3 Panel ID: IFP-100 Ckt. Name: Notification Appl Circuit I/O Use: Notification Appl Grcuit • Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 iii •UIII!1Th.iuitui.ii Project Information Project Name: Zephyrhills WWTF Operations Project ID: 1110 Prepared By: J. Grocke, CET Date: 12/19/2007 Ckt. Number: NAG#4 Panel ID: IFP-100 Ckt. Name: Notification Appl Circuit I/O Use: Notification App1 Circuit [ ] Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000