HomeMy WebLinkAbout08-7320 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 7320
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
X22.
Permit#:7320 Issued: 6/23/2008 Address: 37612 DALIHA TERR#22 LOT 216
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range:
Proposed Use: TOWNHOMES Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: Total Fees: 6,142.72 Subdivision: EILAND PARK TOWNHOMES
Amount Paid: 6,142.72 Date Paid: 6/23/2008 Parcel Number: 03-26-21-0230-00000-2160
Name: LENNAR HOMES INC Name: LENNAR HOMES INC.
Addr: 600 N WESTSHORE BLVD. STE 900 Address: 600 N. WESTSHORE BLVD
TAMPA,FL. 33609 TAMPA, FL 33609
Phone: Lic: Phone: (813)769-5277
Work Desc: NEW TOWNHOME - MARTINQUE - LOT 216 - 1663 SQ FT
BUILDING FEE 727.08 ELECTRICAL FEE 147.15 PLUMBING FEE 98.10
MECHANICAL FEE 68.67 RADON 16.63 SEWER CONNECTION RESIDENT 2,010.00
WATER CONNECTION RESIDENT 641.00 WATER METER RES 3/4" 220.00 FIRE PLAN REVIEW FEES 93.28
FIRE INSPECTION FEES 13.50 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES TOWNHOMES 769.56 SCHOOL IMPACT FEE-sfr/100% 1,740.00
SCHOOL IMPACT FEE-sfr/1% 17.40 TRAFFIC IMPACT FEE 99% —963.27 TRAFFIC IMPACT FEE 1% —9.73
agp
FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80(2)(c)when extra inspection
trips are necessary due to any one of the following reasons: a)wrong address b) condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d)work not ready for
inspection when called e) permit not posted on job site f) plans not at job site g)work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your commencement."
CONT ATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
PERFORMANCE BUSINESS PRODUCTS.INC.813-719-8008 FAX 813-719-7919
CITY OF ZEPHYRHILLS
ZEPHYRHILLS,FLORIDA
WATER ACCT.NO. DATE___________
OE T R ER LPIr
MAIUNG ( Oo JhC5'>_o 1? uG - eb �I C
SERVICE ADDRESS ` LJla Tc�l L.hc err - #22 Lo A- 21(0
Ill WATER <I
SHUT OFF SERVICE ❑
-1 ❑ SEWER
TURN ON SERVICE LM
❑ GARBAGE
INSTALL METER
B'
IN
L`7 IN CITY
READ METER ❑
❑ OUT CITY
CHECK METER ❑
I No.OF UNITS
OTHER ❑
DEPOSIT AMOUNT
-yam
��YYl7 c- — '7o AMOUNT LAST BILL
11 s .\ rL DATE
MISC.CHARGE
WORK COMPLETED BY ORDER TAKEN BY
&DATE COMPLETED
Retain white form in office at all times
Send pink&yellow forms to Water Service Dept.
Water Service Dept.to sign yellow form&return to office.
Lennar-Daliha Ter-37612(lot 216) Martinque Model-Prmt#7320
SQ. FEET PRICE
MAIN OR LIVING: 1,663 $ 94.99
OTHER AREA UNDER ROOF: - $ 94.99
OTHER: - $ -
VALUATION $ 157,968.37
FEE SHEET $ 654.00
ADDRESS $ 30.00
DRIVEWAY $ 30.00
BUILDING: $ 727.08
ELECTRICAL: $ 147.15
PLUMBING: $ 98.10
MECHANICAL: $ 68.67
SUB-TOTAL $ 1,041.00
RADON: $ 16.63
TOTAL $ 1,057.63
SEWER: $ 2,010.00
WATER: $ 641.00
IRRIGATION: $ -
TOTAL: $ 2,651.00
WATER METER: $ 220.00
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: $ 93.28
INSPECTION TOTAL: $ 13.50
PERMIT TOTAL
TOTAL: $ 106.78
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 4,588.76
PARK IMPACT FEES $ 769.56
SIF'S: $ 1,740.00
100.0% $ 1,740.00
1.0% $ 17.40
TOTAL: $ 1,757.40
T I F'S: $ (973.00)] Minus Credit-check on balance
99% $ (963.27j Minus Credit-check on balance
1% $ (9.73) Minus Credit-check on balance
TOTAL: $ 6,142.72
b '
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: ►___
Date Received: 12�IU-7
Site: 1tola. ; - -T2 - - '*ZZ Lo+ ZI("
Permit Type: I __ ho ___
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
' S 4 /
This comment sheet shall be kept with the permit and/or plans.
Kalvin witzer—Plans E er Date Contractor and/or Homeowner
(Required when comments are present)
11/13/08 21:35 FAX 8137695262 LENNAR CORP 9006
CENTRAL. PERMITTING DATE:: 11/04/08 TIMiE: 09:23
PASCO coUHTY. FLORIDAPAt E: I OF' 1
;ONTRACTOR #- 01.7105• ISSUE OFFICE: N
IA04E: :-10EPH .ø R SCI TH . _ RECEIPT NuJ tk. 01115146
DDR: x.5VI"J• KIN) JANES COURT OFFICE: NEit PORT RICH EY
/Si. ijI}E` SA FL 33556
OR: CHE X # 4021
#7320
37612 DALI HA TERR. #22 LOT#216
XlNTRACT[OR: 017105
TOTAL AMOUNT: 10.54
%CCHT Cf3MPNY ACCOUNT CENTER AMOUNT I}ESCRIPTION/PERMT DATA DR/CR
3.14 B450 363000 - 2 10.54 XXEtMx SOLID WASTE FEE 60
.C:EIVED BY
813-78U-(JUZU '. ILy UI LCpIIyrIIIII r-crrint nNNn%.auvi1 ') V
Building Department.�
Date Received $Z�)—7 Phone Contact for Permitting S/ __J .9/B — X53
,/
Owner's Name btiV A/AW ri O,41ES Owner Phone Number 3 ____?(c9____3277
Owner's Address 4 OO N a,,srrµOR.6. f LL0 _A A-33bo4 Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
JOB'ADDRESS 3 76 DAL/_/M I^ER• Z "HyG me $i F` .335�D LOT#
SUBDIVISION. t1L/41/�� .1 /�/�/�-. i PARCEL ID# D. "•2/O-21"0Z3 Q:-.d00j� ""O2 r�Ov
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED ® NEW CONSTR e ADD/ALT = SIGN = MOVE [ DEMOLISH
INSTALL REPAIR
PROPOSED USE = SFR COMM = OTHER
TYPE OF CONSTRUCTION BLOCK FRAME STEEL OTHER
DESCRIPTION OF WORK W :≥,IVS'r (JC:T/O I'..!_ — 7 Q7 '.JAI/-/o/1S
BUILDING SIZE I SQ FOOTAGE I_/_ 3/ I/ HEIGHT `
= BUILDING Is
.,t /r VALUATION OF TOTAL CONSTRUCTION '
= ELECTRICAL •
I_ 'Vo AMP SERVICE PROGRESS ENERGY
PLUMBING l rT�3�SI. I�14C
= MECHANICAL VALUATION OF MECHANICAL INSTALLATION
GAS = ROOFING SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES ='NO,
BUILDER COMPANY NlJg..
SIGNATURE REGISTERED / N FEE CURRENT I_NI
Address �d/v d✓ 7Lfy1AQE B&frD A 33 G0 License SS'7:≤/ I
ELECTRICIAN COMPANY /10 'GAn1 �G>F4f lc. �l/rI Aw "C
SIGNATURE REGISTERED I_ 9/_NI FEE CURRENT....... VIN
/N .
Address 1/ jj1. O ,_NOF S r Gp k!_,e.io 3308 License IC 13 0'S b
PLUMBER COMPANY AR ScryGE:M�ii/ ,P� 4 6/N
SIGNATURE REGISTERED N FEE CURRENT N
Address /'/92 4 f6i2.Qf' ?AM y ..'2_ 33 /3l License# i7 y 72 /!
MECHANICAL COMPANY 8d OA/ET/ ui►'1d/r�esr frfi977�/ �q,1 .
SIGNATURE REGISTERED / N FEE CURRENT ' /N
Address 0. Box 30 84 oNFr,; iJ trf` FL3Y69 License# 9 SS.O. 2'
OTHER COMPANY G'. 'ic1(z- ,l►?�r9ur- ' . 16 .Tvc.
SIGNATURE REGISTERED N FEE CURRENT' N
Address' 5#O4 L/N 8M/D` _4'_ /tG ,C63Y`o License# o ?9 1
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans:(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans;Stormwate.Plans w/Silt Fence Installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R=Q-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater:plans w/;Silt Fence installed,
Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements"r .ist meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
"'PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement Is required. (A/C upgrades over$5000) .
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (Front of Application Only)
Reroofs Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-.Not.over Counter if on public roadways..needs ROW
to"deed"NOTICE OF DEED �tESTRICTIO.NS: The undersigned understands
ttathis
s permit
esmay
onslbiltyect compliance restrictions'any
which may be mere;'restricttve than County regulations. The undersignedP
applicable.deed�re tric�ti na.-
contractor UNLICENSED cONTI ACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired. a r or
l cconntracto o the
contractors to undertake`work,,they may be required to be licensed in accordance with state and local regulations.
contractor Is hot licensed as required by law, both the own s to what I censing requiremenits may apply violation
the
under state law. If the owner or Intended contractor are uncertain a
intended work, they are`advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the'owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES:
The news sigd ngs change of
that Transportation lmpact'F.ees`:and erstands
Recourse Recovery Fees may apply the construction
use in existing buildings or..expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands,
fees,.as may be due, will be Identified at the time of
permitting. Trans must be paid prior to
permitting, It Is further understood that portation Impact Fees and Resource Recovery Fees
receiving a "certificate of occupancy" or final power release. If the project does not iinvolve asco Countyer cate of occupancy or
Water/Sewer Impact
final power release, the fees must be paid prior to permit issuance. Furthermore,
fees are due, they must be.pald, prior to permit issuance in accordance with applicable Pasco Co hty ordinances..
CONSTRUCTION LIEN LAW(Chapter 713, Fidel withta teS as amended) If valuation of copy of the "Florida Construction Lien Law—Homeowner's
certify that I, the; applicant, have been pro
Protection Guide" prep,aretiry the Florida Department of Agriculture and,Consumer Affairs. If the applicant is someone
, the
other than the"owner";"I certify,that I have obtained a copy of the above described document and promise In good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I c that
construction,n zonls ing application is accurate
land development. all work is
will be done In compliance with all applicable laws regulating
hereby made to obtain a permit to Bonn wot rk nd that all installation
will be performed,toemeetrtify that no work or standards of all lawsilation has
regulating
commenced prior to issuance of a per
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I Understand that the regulations of other government
take to be in compliance.ies may appl to the inndd work, and th Such agencies include but not limited tot:it is
my responsibility to identify what actions I
- Department of Environmental Protection-Cypress Bayheads, Wetland.Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment. Bayheads, Wetland Areas, Altering
Southwest' Florida Water Management District-Wells, Cypress y
Watercourses.,
Army Corps of.Engineers-Seawalls, Docks, Navigable Waterways.
Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks
US Environmental Protection Agency
-�sbestos abatement.
Federal Aviation Authority-Runways.
I understand that the following restrictions apply
to the use of fill:
_ Use of fill is not allowed in Flood Zone."V" unless expressly permitted. e plan
a
If the fill material us to be used, e permitting which is prepared rby a gprofessiona reng neer
"compensating volume will be submitted at time of
licensed by the State of Florida.
_ If the' fill material Is to be used in Flood Zone "A" in connection
with
permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem w
If fill material is to be used in any area, I certify that use of such fill will hot adversely affect adjacent
ro erties. If use of fill is found to adversely affect adjacent
pr properties,
applicat the wner for ay lots`less thanrviolating
P P permit issued under the permit the conditions of the building
acre which are elevated by fill, an engineered drainage plan is required.If I m owner of the itting this a
the AGENT FOR THEOWNER, I promise in good faith
that inform separate permit may be required for conditions
electrical forth
work;
this affidavit prior to commencing construction. I,unders a
lica ion.
plumbing, signs,
wells, pools, air conditioning, gas, or other installations not specifically included in the app
th e wprk and not as , cance ter, or
,per
mlt Issued shall be construed to be a license to proceed issuaincehof a permit prevent the Building Officeial frorrik elinaalid
fter
set aside any provisions of the technical codes, nor shall
requiring a correction of errors in plans, is constructionithin sixions of of permi permit issued
ordif woll become rk authorized
dlby
q 9
unless the work authorized by such permit is comet g0 days and will demonstrate
on
the*permit is suspended or abandoned for Buildingol of six( ) months after the time ial fora period not to exceedtnin work
is) ommenced. An day, d abandoned.
may be requested, in writing, from the Bu 9 gp consecutive days, th�job is cons
justifiable cause for the extension. If work ceases for ninety( ) T MAY RESULT IN YOUR
G TO OWNER: YOUR FAILURE TO RECORPERTY TI YOU IN OF OEN C FIN RESULT
, CONSULT
WARNING S TO YOUR PRO NCEIVIENT.
PAYING TWICE FOR IMPR V : EY BE ORE RECD ING Y R N
WIT U E ER
FLORIDA JURAT(F.S. 11 CONTRACTOR
ore me this aEcErodEti
OyyN ibed AGENT this 0If4EMBf2— Subscribed and savor to
Subscribed and sworn to r
e o /yrw, zv 7 by
�¢f f,Zo0 by aslhave produced Who i rsonally knownto a or has/have Produce
as identification.
Who is"— /personally known ss identlficatlon.
Notary Public
Notary Public
Commission No. D 32 4 SO
Commission No.
ed, Anted or stamped
Name of Notary typ P =
Name o r Ellasa M. Holleran.
Elissa M. Holleran
A-Commission#DO3Z8507
Commission#DD326507i ! ? Expires June 6,2008
,004
Expires June 6,2008 '�; ,;, io"wnwrw•M. ,"' °1
r.`C�`amd.d T,ev Ftln•Mwnr�, ..7010
FORM 600A-2004R EnergyGauge®4.5.2
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: US1531M-MARTINIQUE - 1531 S.F. LIVING AREABuilder:
Address: �._j 2 . 0 Zi to Permitting Office: �C��-a t 5
h shill
City, State: Permit Number:
Owner: ,
�..�.\.z`\\ t t~ 130
1,-enn l-�arneS Jurisdiction Number: C (Dp p
Climate Zone: Central
1. New construction or existing New — 12. Cooling systems
2. Single family or multi-family Multi-family — a. Central Unit Cap:28.8 kBtu/hr _
3. Number of units,if multi-family 4 _ SEER: 13.00
4. Number of Bedrooms 2 _ b.N/A —
5. Is this a worst case? Yes _ _ —
6. Conditioned floor area(ft2) 1531 ft2 c. N/A
7. Glass type I and area:(Label reqd.by 13-104.4.5 if not default)
a. U-factor: Description Area 13. Heating systems
(or Single or Double DEFAULT) 7a(Sngle Default) 127.0 ft2 a. Electric Heat Pump Cap:27.8 kBtu/hr
b. SHGC: —
(or Clear or Tint DEFAULT) 7b. 2 HSPF:8.00 —
(Clear) 127.0 ft b.N/A
8. Floor types —
a. Slab-On-Grade Edge Insulation R=0.0,134.0(p)ft _ c. N/A
b. Raised Wood,Post or Pier R=11.0, 124.0ft2 _ —
c. N/A — 14. Hot water systems
9. Wall types a. Electric Resistance Cap:40.0 gallons _
a. Concrete,Int Insul,Exterior R=4.1,789.0 ft2 — EF:0.92 _
b. Concrete,Int Insul,Adjacent R=4.1, 1400.0 ft2 b.N/A
c. N/A —d. N/A _ c. Conservation credits
e. N/A — (HR-Heat recovery,Solar
10. Ceiling types — DHP-Dedicated heat pump)
a. Under Attic R=30.0,878.0 ft2 15. HVAC credits PT
b.N/A — (CF-Ceiling fan,CV-Cross ventilation,
c. N/A HF-Whole house fan,
11. Ducts _ PT-Programmable Thermostat,
a. Sup:Unc. Ret:Con. AH(Sealed):Interior Sup.R=6.0, 150.0 ft MZ-C-Multizone cooling,
b.N/A — MZ-H-Multizone heating)
LGtasslFboor Area: 0.08 Total as-built points: 15740 PASS
Total base points: 17780
hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this p4TKE ST'�l�
Code. calculation indicates compliance
PREPARED BY: with the Florida Energy Code.
„ off
DATE: I Before construction is completed
this building will be inspected for
I hereby certify that this build designed, is in compliance compliance with Section 553.908
with the Florida Energy Co Florida Statutes. V
OWNER/AGENT: BUILDING OFFICIAL: CODS
DATE 7
1 Predominant glass type.For actual glass type and areas,see Summer&Winter Glass output on pages 2&4.
EnergyGauge®(Version: FLRCSB v4.5.2)
FORM 600A-2004R EnergyGauge®4.5.2
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: US1531 M- MARTINIQUE -1531 S.F. LIVING AREABuilder: HOMES
Address: 3Z ( �Z ) l rr, Permitting Office:
City, State: Permit Number:
Owner: Z �V �. �1< , C�
Jurisdiction Number:
Climate Zone: Central
I. New construction or existing New 12. Cooling systems
2. Single family or multi-family Multi-family a. Central Unit Cap:28.8 kBtu/hr
3. Number of units,if multi-family 4 SEER: 13.00 _
4. Number of Bedrooms 2 b. N/A
5. Is this a worst case? Yes
6. Conditioned floor area(ft2) 1531 ft2 _ c. N/A
7. Glass type'and area:(Label reqd.by 13-104.4.5 if not default) —
a. U-factor: Description Area 13. Heating systems
(or Single or Double DEFAULT) 7a(Sngle Default) 127.0 ft2 — a. Electric Heat Pump Cap:27.8 kBtu/hr
b. SHGC: —
(or Clear or Tint DEFAULT) 7b. HSPF:8.00 —
(Clear) 127.0 ft2 — b.N/A
8. Floor types
a. Slab-On-Grade Edge Insulation R=0.0, 134.0(p)ft c. N/A
b. Raised Wood,Post or Pier R=I 1.0, 124.0ft2
c. N/A _ 14. Hot water systems
9. Wall types a. Electric
Resistance Cap:40.0 gallons _
a. Concrete,Int Insul,Exterior R=4.1,789.0 112 EF:0.92
b. Concrete,Int Insul,Adjacent R=4.1, 1400.0 ft2 b. N/A
c. N/A
d. N/A _ c. Conservation credits
e. N/A (HR-Heat recovery,Solar
10. Ceiling types — DHP-Dedicated heat pump)
a. Under Attic R=30.0,878.0 ft2 15. HVAC credits PT,
b.N/A — (CF-Ceiling fan,CV-Cross ventilation,
c. N/A - HF-Whole house fan,
11. Ducts — PT-Programmable Thermostat,
a. Sup:Unc. Ret:Con. AH(Sealed):Interior Sup.R=6.0, 150.0 ft MZ-C-Multizone cooling,
b.N/A — MZ-H-Multizone heating)
Glass/Floor Area: 0.08 Total as-built points: 15740 PASS
Total base points: 17780
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this O,,OtEST,�TA
Code. 1 calculation indicates compliance
PREPARED BY: with the Florida Energy Code.
DATE: Before construction is completed
this building will be inspected for
I hereby certify that this buildi g, as esigned, is in compliance compliance with Section 553.908 ff
with the Florida Energy Code Florida Statutes. f�
OWNER/AGENT; BUILDING OFFICIAL:
DATE: / ___ ___
DATE:
1 Predominant glass type.For actual glass type and areas,see Summer&Winter Glass output on pages 2&4.
EnergyGauge®(Version: FLRCSB v4.5.2)
FORM 600A-2004R EnergyGauge®4.5.2
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT#:
BASE AS-BUILT
GLASS TYPES
.18 X Conditioned X BSPM = Points Overhang
Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points
.18 1531.0 24.35 6710.0 1.Single,Clear W 1.3 6.0 16.0 57.68 0.94 863.0
2.Single,Clear W 6.0 4.0 7.0 57.68 0.46 187.0
3.Single,Clear E 6.0 9.0 40.0 63.97 0.64 1642.0
4.Single,Clear W 1.3 6.0 16.0 57.68 0.94 863.0
5.Single,Clear W 1.3 10.0 16.0 57.68 0.99 912.0
6.Single,Clear E 1.3 6.0 32.0 63.97 0.94 1917.0
As-Built Total: 127.0 6384.0
WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points
Adjacent 1400.0 0.70 980.0 1.Concrete,Int Insul,Exterior 4.1 789.0 1.18 931.0
Exterior 789.0 1.90 1499.1 2.Concrete, Int Insul,Adjacent 4.1 1400.0 0.65 903.0
Base Total: 2189.0 2479.1 As-Built Total: 2189.0 1834.0
DOOR TYPES Area X BSPM = Points Type Area X SPM = Points
Adjacent 0.0 0.00 0.0 1.Exterior Wood 20.0 7.20 144.0
Exterior 20.0 4.80 96.0
Base Total: 20.0 96.0 As-Built Total: 20.0 144.0
CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points
Under Attic 878.0 2.13 1870.1 1.Under Attic 30.0 878.0 2.13 X 1.00 1870.1
Base Total: 878.0 1870.1 As-Built Total: 878.0 1870.1
FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points
Slab 134.0(p) -31.8 -4261.2 1.Slab-On-Grade Edge Insulation 0.0 134.0(p -31.90 -4274.6
Raised 124.0 -3.43 -425.3 2. Raised Wood, Post or Pier 11.0 124.0 1.83 226.3
Base Total: -4686.5 As-Built Total: 258.0 -4048.3
INFILTRATION Area X BSPM = Points Area X SPM = Points
1531.0 14.31 21908.6 1531.0 14.31 21908.6
EnergyGauge®DCA Form 600A-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2
FORM 600A-2004R EnergyGauge®4.5.2
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT#:
BASE AS-BUILT
Summer Base Points: 28377.3 Summer As-Built Points: 28092.5
Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(System - Points) (DM x DSM x AHU)
(sys 1:Central Unit 28800btuh,SEER/EFF(13.0)Ducts:Unc(S),Con(R),lnt(AH),R6.0(INS)
28092 1.00 (1.08 x 1.150 x 0.85) 0.260 0.950 7361.6
28377.3 0.3250 9222.6 28092.5 1.00 1.061 0.260 0.950 7361.6
EnergyGaugeTM DCA Form 600A-2004R EnergyGauge®/FIaRES'2004R FLRCSB v4.5.2
FORM 600A-2004R EnergyGauge®4.5.2
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT#:
BASE s AS-BUILT
GLASS TYPES
.18 X Conditioned X BWPM = Points Overhang
Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point
.18 1531.0 9.11 2511.0 1.Single,Clear W 1.3 6.0 16.0 13.25 1.01 213.0
2.Single,Clear W 6.0 4.0 7.0 13.25 1.10 102.0
3.Single,Clear E 6.0 9.0 40.0 12.37 1.10 542.0
4.Single,Clear W 1.3 6.0 16.0 13.25 1.01 213.0
5.Single,Clear W 1.3 10.0 16.0 13.25 1.00 211.0
6.Single,Clear E 1.3 6.0 32.0 12.37 1.01 401.0
As-Built Total: 127.0 1682.0
WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points
Adjacent 1400.0 1.80 2520.0 1. Concrete, Int Insul,Exterior 4.1 789.0 3.31 2607.6
Exterior 789.0 2.00 1578.0 2.Concrete,Int Insul,Adjacent 4.1 1400.0 2.08 2912.0
Base Total: 2189.0 4098.0 As-Built Total: 2189.0 5519.6
DOOR TYPES Area X BWPM = Points Type Area X WPM = Points
Adjacent 0.0 0.00 0.0 1.Exterior Wood 20.0 7.60 152.0
Exterior 20.0 5.10 102.0
Base Total: 20.0 102.0 As-Built Total: 20.0 152.0
CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points
Under Attic 878.0 0.64 561.9 1. Under Attic 30.0 878.0 0.64 X 1.00 561.9
Base Total: 878.0 561.9 As-Built Total: 878.0 561.9
FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points
Slab 134.0(p) -1.9 -254.6 1.Slab-On-Grade Edge Insulation 0.0 134.0(p 2.50 335.0
Raised 124.0 -0.20 -24.8 2. Raised Wood,Post or Pier 11.0 124.0 0.47 58.4
Base Total: -279.4 As-Built Total: 258.0 393.4
INFILTRATION Area X BWPM = Points Area X WPM = Points
1531.0 -0.28 -428.7 1531.0 -0.28 -428.7
EnergyGauge®DCA Form 600A-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2
FORM 600A-2004R EnergyGauge®4.5.2
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT#:
BASE g AS-BUILT
Winter Base Points: 6564.8 Winter As-Built Points: 7880.3
Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(System - Points) (DM x DSM x AHU)
(sys 1:Electric Heat Pump 27800 btuh,EFF(8.0)Ducts:Unc(S),Con(R),Int(AH),R6.0
7880.3 1.000 (1.068 x 1.160 x 0.87)0.427 0.950 3458.2
6564.8 0.5540 3636.9 7880.3 1.00 1.083 0.427 0.950 3458.2
EnergyGaugeTM DCA Form 600A-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2
FORM 600A-2004R EnergyGauge®4.5.2
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT#:
BASE a AS-BUILT
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
2 2460.00 4920.0 40.0 0.92 2 1.00 2460.00 1.00 4920.0
As-Built Total: 4920.0
CODE COMPLIANCE STATUS
BASE AS-BUILT
Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total
Points Points Points Points Points Points Points Points
9223 3637 4920 17780 7362 3458 4920 15740
PASS
yp4 THE ST,gl�os
a d
EnergyGaugeTM DCA Form 600A-2004R EnergyGauge®/FIaRES'2004R FLRCSB v4.5.2
FORM 600A-2004R EnergyGauge®4.5.2
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT#:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS SECTION REQUIREMENT FOR EACH PRACTICE CHECK
Exterior Windows&Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft.window area; 5 cfm/sg ft.door area.
Exterior&Adjacent Walls 606.1.ABC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall;
foundation&wall sole or sill plate;joints between exterior wall panels at corners; utility
penetrations;between wall panels&top/bottom plates;between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from,and is sealed to,the foundation to the top plate.
Floors 606.1.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members.
EXCEPTION:Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter penetrations and seams.
Ceilings 606.1.ABC.1.2.3 Between walls&ceilings;penetrations of ceiling plane of top floor;around shafts,chases,
soffits,chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the erimeter,at enetrations and seams.
Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated,installed inside a
sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from
conditioned space,tested.
---------- ----- ------
Multi-story ouses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS SECTION REQUIREMENTS CHECK
Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir
breaker(electric)or cutoff(gas)must be�rovided. External or built-in heat trap required.
Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated). Non-commercial pools
must have a pump timer.Gas spa&pool heaters must have a minimum thermal
efficient of78%.
Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically
attached,sealed,insulated,and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics:R-6 min. insulation.
HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system.
Insulation 604.1,602.1 Ceilings-Min. R-19.Common walls-Frame R-11 or CBS R-3 both sides.
Common ceiling&floors R-1 1.
EnergyGaugeTM DCA Form 600A-2004R EnergyGauge®/FIaRES'2004R FLRCSB v4.5.2
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 88.0
The higher the score,the more efficient the home.
1. New construction or existing New — 12. Cooling systems
2. Single family or multi-family Multi-family — a. Central Unit Cap:28.8 kBtu/hr _
3. Number of units,if multi-family 4 — SEER: 13.00
4. Number of Bedrooms 2 _ b.N/A
5. Is this a worst case? Yes _
6. Conditioned floor area(112) 1531 ft2 c. N/A
7. Glass type I and area:(Label reqd.by 13-104.4.5 if not default)
a. U-factor: Description Area 13. Heating systems
(or Single or Double DEFAULT) 7a(Sngle Default)127.0 ft2 — a. Electric Heat Pump Cap:27.8 kBtu/hr _
b. SHGC: HSPF:8.00 _
(or Clear or Tint DEFAULT) 7b. (Clear) 127.0 ft2 _ b. N/A
8. Floor types
a. Slab-On-Grade Edge Insulation R=0.0, 134.0(p)ft c. N/A
b. Raised Wood,Post or Pier R=11.0, 124.0112 _
c. N/A 14. Hot water systems
9. Wall types a. Electric Resistance Cap:40.0 gallons
a. Concrete,Int Insul,Exterior R=4.1,789.0 ft2 EF:0.92 _
b. Concrete,Int Insul,Adjacent R=4.1, 1400.0 ft2 _ b.N/A
c. N/A
d. N/A c. Conservation credits _
e. N/A _ (HR-Heat recovery,Solar
10. Ceiling types DHP-Dedicated heat pump)
a. Under Attic R=30.0,878.0 ft2 — 15. HVAC credits PT
b. N/A — (CF-Ceiling fan,CV-Cross ventilation,
c. N/A — HF-Whole house fan,
11. Ducts PT-Programmable Thermostat,
a. Sup:Unc. Ret:Con. AH(Sealed):Interior Sup.R=6.0, 150.0 ft _ MZ-C-Multizone cooling,
b.N/A _ MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building Z8E sT
Construction through the above energy saving features which will be installed(or exceeded)
in this home before final inspection.Otherwise,a new EPL Display Card will be completed ,,;'''� =
based on installed Code compliant features. "
Builder Signature: Date:
Address of New Home: City/FL Zip:
*NOTE: The home's estimated energy performance score is only available through the FLA/RES computer program.
This is not a Building Energy Rating. If your score is 80 or greater(or 86 for a US EPA/DOE EnergyStardesignation),
your home may qualms for energy efficiency mortgage(EEM)incentives ifyou obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site at www.fsec.ucfedu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building
Construction, contact the Department of Community Affairs at 850/487-1824.
1 Predominant glass type.For actual glass type and areas,see Summer&Winter Glass out ut on ages 2&4.
EnergyGauge®(Version:FLRCSB v4.5.2)
MAR-19-2787 11:25 SIMPSON MECHANICAL 813 558 8578 P.16
4 igiitsott- Load Short Form .rte: iwARTINIQUe-1531 S.,..
Entire House By'1112 005
By: TRH
SIMPSON MECHANICAL
For- U.S. HOMES
HOutside db(°F) 40 t 9g 2 Infiltration: ::
Inside db(°F) 70Method � Simplified
Design TD(°F) 30 75 Construction quality Average
Daily range - Fireplaces 0
Inside humidity(%) - L
52 Moisture difference(grub) -
HEATING EQUIPMENT COOLING EQUIPNT
Make Carrier Make Carrier
Trade Base 13 Puron HP Trade Base 13 Puron HP
Model 25HBA330A30 Cond 25HBA330A30
Efficiency 8.3 HSPF Coil FY4ANF030
Efficiency 13 SEER Heating input
Heating output Sensible cooling .21570 Btuh
tP 31800 Btuh( 47°F Latent cooling :7630 Btuh
Temperature rise 29 °F Total cooling 900 Btuh
Actual air flow 1000 cfm Actual air flow
Air flow factor 0.044 cfm/Btuh Air flow factor 1904 cfm
Static pressure 0.00 in H Static 2O 0. 51 in H2O h
Space thermostat pressure 0!00 H2O
Load sensible heat ratio ;0.84
ROOM NAME Area Htg load Gig load Htg A17F`: Cig AVE
(ft) (Btuh) (Btuh) (cfm) ' (cfm)
FOYER 68 2777 1975 1'2 101
KITCHEN-NOOK 100 1834 1772
DINING 160 1622 91
POWDER-STAIRS 131 1269 296 56
296 19
LIVING 297 7432 56 , 15
STAIRS-HALL 102 5111 32'8 262
MASTER B.R. 239 446 37S 7b 19
MASTER BATH 3206 4478 141 230
FLEX ROOM 58 195 173 9! , 9
HALL BATH 146 686 571 30 29
B.R.#2 174 3025 4180 158 195 173 215
5
Ho1W►N//*wlusa flaw boon menuemy oyerylddp4'p
Printout certified byACCA to meet all requirements of Manual J 8th Ed.
wrightsafic RI#hl-SuiteRaadeMfal6.0.1ooFZSR4381a
Z:\Tommy►1vACWS1S31MJe.rrp Caicvttia O n vW !• 1007-Mar-lo 12:07:24
MAR-19-2007 11:25 SIMPSON MECHANICAL 813 558 8578 P. 17
Entire House 1531 22686 19482 1000 1000
Other equip loads 1059 614
Equip. 0.97 RSM 19573
Latent cooling 3824
TOTALS 1531 23745 23397 1000 1000
8old//Wlc values heve be manually owrndden
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
wnghtsot Rlght&idle Reeldeni el 1,0.100 RBR43B73 2oo7.Mar•t912 072
ACC Z1TOy HVAC1U81331 MJB,rrp ClIC=MJ8 Orientation.W
Page 2
1111111 IIIII Ilill 11111 11111 11111 11111 11111 11111 11111 1111 1111
2008089279
Rcpt: 1186756 Rec: 10.00
DS: 0.00 IT: 0.00
06/16/08 Dpty Clerk
NOTICE OF COMMENCEMENT JED 16 PI08 1 , PASCO COUNTY CLERK
08 11:57am 1 of 1
OR BK 7861 PG 1943
Permit No.
Property Identification No'03-.?L--7/- p�30_ —ppoO_Z160
THE UNDERSIGNED hereby give informs you that the improvement will be made to certain real property,and in accordance with
Section 113 13 of the Florida Statutes,the following information is provided in this NOTICE OF COMMENCEMENT
1.Description of property(legal description:)LQ r 2l( IQo,�k To /Mo S , öly Pis/
p.
a)Street Address: 3 7 / G/ 7Z '
2.General description of improvements: JIN6LE ,AM/ ibex/ rc , ,
3.Owner Information
a)Name and address: LENN'c, xl fE& J/c . G 00 /V. tJdsrJNo,cE 34.vo,1 g , L L J3 6o9
q
b)Name and address of fee simple titleholder(if other than owner)
c)Interest in property
ntractor Information
a)Name and address: ..5TEYES'nrn,rN—. GOO ,4f WJdsrSNo2E l3& o.s'rE LDO , tWA/ �t 334o9
b)Telephone No.: Al 13) ?(.9-5277 Fax No.(Opt.)
5.Surety Information
a)Name,and address: NIA
b)Amount of Bond: 'jig
c)Telephone No.: Fax No.(Opt.)
6.Lender
a)Name and address:
Phone No.
7. Identity of person within the State of Florida designated by owner upon whom notices or other documents may be served:
a)Name and address:JYEVEJi,r,g— (.c o 4/. AA sTJNoRf &t D, .5rE 600 T,vy # F,4 3 ci
b)Telephone No.: (813) 7 —.S2 7'7 Fax No. (Opt.)
8.In addition to himself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Section
713.13(1)(b),Florida Statutes:
a)Name and address: ,yZA
b)Telephone No.: Fax No.(Opt.)
9.Expiration date of Notice of Commencement(the expiration date is one year from the date of recording unless a different date is
specified):
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF
COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART I,SECTION 713.13,
FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS.TO YOUR.PROPERTY.
A NOTICE OF COMMENCEMENT MUST BE RECORDED.AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT YOUR LENDER OR AN ATTORNEY BEFORE.
COMMENCING WORK OR RECORDING YOUR NOTICE OF COM MENT.
STATE OF FLORIDA I
Signature of or Owner's Authorized Officer/Director/Partner/Manager
/ L/dget .f' J7 W/ 'V$
Print Name
The foregoing,instrument was acknowledged before me this I3rµ day of .J utV E .2O 0 a by' _1i e N,9E 1 k
.5'7E VS as MANAG E PL (type of authority,e.g. officer,trustee,attorney
in fact)for LENNvAR. 6Xi009AT,o AJ (name of party on behalf of whom ins ant was executed).
Personally Known ✓ OR Produced Identification Notary Signature
Type of IdentificationProduced.�_ Name(print) £L..,S sA Na c e E rt�n.�
Verification pursuant to Section 92.525,Florida Statutes.Under penalties of.perjury,I declare that I have read the foregoing and that
the facts stated;in it are true to the best of my knowledge and-belief..
Si cure o erson.Signing Above
F0RMS0C.r a 2OO7
� EUSSA M.HOLLERAN
Commission DD 774023
Expires June 6,2012
6a,did Z:Troy F&%4rua,po 990,*6.7919
STATE OF FLOP`DA
COUNTY OF PAS'O
THIS IS TO CERTIFY THAT THE Ffl aO M'
TRUE AND CORRECT COPY OF YK 00C
OR OF PUBLIC RECORD IN THIS OrFIC J 1
D AND OFFICIAL SEAL THI
DA,
D ITTM ^LERK QF cICICUIT GCI�r)
FORM.600A-2004R EnergyGauge®4.5.2
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: US1531 M- MARTINIQUE -1531 S.F. LIVING AREABuilder: U.S. HOMES / /-
Address: �_T G\� y t � `C. Permitting Office: C,' o4 242k41rYt c 16
City, State: _ Permit Number: JJ
Owner: c :,,'ti ..�\ � 32 6
Jurisdiction Number: & 1l(Poo
Climate Zone: Central
1. New construction or existing New — 12. Cooling systems
2. Single family or multi-family Multi-family — a. Central Unit Cap:28.8 kBtu/hr _
3. Number of units,if multi-family 4 — SEER: 13.00
4. Number of Bedrooms 2 _ b. N/A 5. Is this a worst case? Yes
6. Conditioned floor area(ft2) 1531 fV c. N/A —
7. Glass typeI and area:(Label regd.by 13-104.4.5 if not default)
a. U-factor: Description Area 13. Heating systems
(or Single or Double DEFAULT) 7a(Sngle Default) 127.0 ft2 a. Electric Heat Pump Cap:27.8 kBtu/hr _
b. SHGC: HSPF:8.00
(or Clear or Tint DEFAULT) 7b. (Clear) 127.0 ft2 _ b. N/A
8. Floor types a. Slab-On-Grade Edge Insulation R=0.0,134.0(p)ft _ c. N/A
b. Raised Wood,Post or Pier R=11.0, 124.0112 —
c. N/A — 14. Hot water systems
9. Wall types a. Electric Resistance Cap:40.0 gallons _
a. Concrete,hit Insul,Exterior R=4.1,789.0 ft2 — EF:0.92
b. Concrete,hit Insul,Adjacent R=4.1, 1400.0 ft2 b. N/A
c. N/A d.N/A _ c. Conservation credits
e. N/A (HR-Heat recovery,Solar
10. Ceiling types DHP-Dedicated heat pump)
a. Under Attic R=30.0,878.0 ft2 15. HVAC credits PT,
b.N/A (CF-Ceiling fan,CV-Cross ventilation,
c. N/A — HF-Whole house fan,
11. Ducts — PT-Programmable Thermostat,
a. Sup:Unc. Ret:Con. AH(Sealed):Interior Sup.R=6.0, 150.0 ft MZ-C-Multizone cooling,
b.N/A — MZ-H-Multizone heating)
Glass/Floor Area: 0.08 Total as-built points: 15740 I'AS S
_P ___
i'll
Total base points: 17780
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this p�ZIiBSTg1�
Code. calculation indicates compliance
PREPARED BY: with the Florida Energy Code.
DATE: I Before construction is completed ►�
this building will be inspected for
1 hereby certify that this buildi a designed, is in compliance compliance with Section 553.908 tr
with the Florida Energy Cod LFlorida Statutes.
wE
OWNERIAGENT: BUILDING OFFICIAL:
DATE: DATE: __ � 7 (� �(
1 Predominant glass type.For actual glass type and areas,see Summer&Winter Glass output on pages 2&4.
EnergyGauge®(Version: FLRCSB v4.5.2)
FORM 600A-2004R EnergyGauge®4.5.2
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name. US1531 M-MARTINIQUE-1531 S.F. LIVING AREABuilder U.S. HOMES
Address: l Permitting Office:
City, State: Permit Number:
Owner: ,e.���� .:1�s �_. a
Jurisdiction Number:
Climate Zone: Central
1. New construction or existing New _ T12. Cooling systems
2. Single family or multi-family Multi-family a. Central Unit Cap:28.8 kBtu/hr —�
3. Number of units,if multi-family 4 — SEER: 13.00 _
4. Number of Bedrooms 2 b. N/A
5. Is this a worst case? Yes
6. Conditioned floor area(ft2) 1531 ft2 c. N/A
7. Glass type I and area:(Label reqd.by 13-104.4.5 if not default) —
a. U-factor: Description Area 13. Heating systems
(or Single or Double DEFAULT) 7a(Sngle Default) 127.0 ft2 — a. Electric Heat Pump Cap:27.8 kBtu/hr _
b. SHGC: HSPF:8.00
(or Clear or Tint DEFAULT) 7b. (Clear) 127.0 ft2 — b. N/A
8. Floor types —
a. Slab-On-Grade Edge Insulation R=0.0, 134.0(p)ft _ c. N/A
b.Raised Wood,Post or Pier R=I1.0, 124.0ft2 _
c. N/A 14. Hot water systems
9. Wall types a. Electric Resistance Cap:40.0 gallons _
a. Concrete,Int Insul,Exterior R=4.1,789.0 ft2 EF:0.92 _
b. Concrete,Int Insul,Adjacent R=4.1, 1400.0 ft2 b. N/A
c. N/A —
d. N/A _ c. Conservation credits
e. N/A _ (HR-Heat recovery,Solar
10. Ceiling types — DHP-Dedicated heat pump)
a. Under Attic R=30.0,878.0 ft2 15. HVAC credits PT,
b.N/A (CF-Ceiling fan,CV-Cross ventilation,
c. N/A _ HF-Whole house fan,
11. Ducts _ PT-Programmable Thermostat,
a. Sup:Unc. Ret:Con. AH(Sealed):Interior Sup.R=6.0, 150.0 ft MZ-C-Multizone cooling,
b.N/A — MZ-H-Multizone heating) _J
Glass/Floor Area: 0.08 Total as-built points: 15740 PAS
S�
Total base points: 17780 /`1
I hereby certify that the plans and specifications covered by Review of the plans and
Code. calculation indicates compliance
this calculation are in compliance with the Florida Energy specifications covered by this -,TftE Sr42T
~���%
PREPARED BY: with the Florida Energy Code. ti ,,,,,
DATE: Before construction is completed
this building will be inspected for
I hereby certify that this build g, s designed, is in compliance compliance with Section 553.908
with the Florida Energy Cod Florida Statutes. y"t
OWNER/AGEN BUILDING OFFICIAL:
DATE: DATE:
1 Predominant glass type. For actual glass type and areas,see Summer&Winter Glass output on pages 2&4.
EnergyGauge®(Version: FLRCSB v4.5.2)
FORM 6,00A-2004R EnergyGauge®4.5.2
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT#:
BASE a AS-BUILT
GLASS TYPES
.18 X Conditioned X BSPM = Points Overhang
Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF= Points
.18 1531.0 24.35 6710.0 1.Single,Clear W 1.3 6.0 16.0 57.68 0.94 863.0
2.Single,Clear W 6.0 4.0 7.0 57.68 0.46 187.0
3.Single,Clear E 6.0 9.0 40.0 63.97 0.64 1642.0
4.Single,Clear W 1.3 6.0 16.0 57.68 0.94 863.0
5.Single,Clear W 1.3 10.0 16.0 57.68 0.99 912.0
6.Single,Clear E 1.3 6.0 32.0 63.97 0.94 1917.0
As-Built Total: 127.0 6384.0
WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points
Adjacent 1400.0 0.70 980.0 1.Concrete, lnt Insul, Exterior 4.1 789.0 1.18 931.0
Exterior 789.0 1.90 1499.1 2.Concrete, Int Insul,Adjacent 4.1 1400.0 0.65 903.0
Base Total: 2189.0 2479.1 As-Built Total: 2189.0 1834.0
DOOR TYPES Area X BSPM = Points Type Area X SPM = Points
Adjacent 0.0 0.00 0.0 1.Exterior Wood 20.0 7.20 144.0
Exterior 20.0 4.80 96.0
Base Total: 20.0 96.0 As-Built Total: 20.0 144.0
CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points
Under Attic 878.0 2.13 1870.1 1.Under Attic 30.0 878.0 2.13 X 1.00 1870.1
Base Total: 878.0 1870.1 As-Built Total: 878.0 1870.1
FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points
Slab 134.0(p) -31.8 -4261.2 1.Slab-On-Grade Edge Insulation 0.0 134.0(p -31.90 -4274.6
Raised 124.0 -3.43 -425.3 2.Raised Wood,Post or Pier 11.0 124.0 1.83 226.3
Base Total: -4686.5 As-Built Total: 258.0 -4048.3
INFILTRATION Area X BSPM = Points Area X SPM = Points
1531.0 14.31 21908.6 1531.0 14.31 21908.6
EnergyGauge®DCA Form 600A-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2
FORM 600A-2004R EnergyGauge®4.5.2
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT#:
BASE AS-BUILT
Summer Base Points: 28377.3 Summer As-Built Points: 28092.5
Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(System - Points) (DM x DSM x AHU)
(sys 1:Central Unit 28800btuh,SEER/EFF(13.0)Ducts:Unc(S),Con(R),Int(AH),R6.0(INS)
28092 1.00 (1.08x 1.150x 0.85) 0.260 0.950 7361.6
28377.3 0.3250 9222.6 28092.5 1.00 1.061 0.260 0.950 7361.6
EnergyGaugeTM DCA Form 600A-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2
FORM 600A-2004R EnergyGauge®4.5.2
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT#:
BASE AS-BUILT
GLASS TYPES
.18 X Conditioned X BWPM = Points Overhang
Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point
.18 1531.0 9.11 2511.0 1.Single,Clear W 1.3 6.0 16.0 13.25 1.01 213.0
2.Single,Clear W 6.0 4.0 7.0 13.25 1.10 102.0
3.Single,Clear E 6.0 9.0 40.0 12.37 1.10 542.0
14.Single,Clear W 1.3 6.0 16.0 13.25 1.01 213.0
5.Single,Clear W 1.3 10.0 16.0 13.25 1.00 211.0
6.Single,Clear E 1.3 6.0 32.0 12.37 1.01 401.0
As-Built Total: 127.0 1682.0
WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points
Adjacent 1400.0 1.80 2520.0 1.Concrete,Int Insul,Exterior 4.1 789.0 3.31 2607.6
Exterior 789.0 2.00 1578.0 2. Concrete, Int Insul,Adjacent 4.1 1400.0 2.08 2912.0
Base Total: 2189.0 4098.0 As-Built Total: 2189.0 5519.6
DOOR TYPES Area X BWPM = Points Type Area X WPM = Points
Adjacent 0.0 0.00 0.0 1.Exterior Wood 20.0 7.60 152.0
Exterior 20.0 5.10 102.0
Base Total: 20.0 102.0 As-Built Total: 20.0 152.0
CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points
Under Attic 878.0 0.64 561.9 1.Under Attic 30.0 878.0 0.64 X 1.00 561.9
Base Total: 878.0 561.9 As-Built Total: 878.0 561.9
FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points
Slab 134.0(p) -1.9 -254.6 1.Slab-On-Grade Edge Insulation 0.0 134.0(p 2.50 335.0
Raised 124.0 -0.20 -24.8 2. Raised Wood,Post or Pier 11.0 124.0 0.47 58.4
Base Total: -279.4 As-Built Total: 258.0 393.4
INFILTRATION Area X BWPM = Points Area X WPM = Points
1531.0 -0.28 -428.7 1531.0 -0.28 -428.7
EnergyGauge®DCA Form 600A-2004R EnergyGauge®/FIaRES'2004R FLRCSB v4.5.2
FORM 600A-2004R EnergyGauge®4.5.2
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , PERMIT#:
BASE a AS-BUILT
Winter Base Points: 6564.8 Winter As-Built Points: 7880.3
Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating
Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points
(System - Points) (DM x DSM x AHU)
(sys 1: Electric Heat Pump 27800 btuh,EFF(8.0)Ducts:Unc(S),Con(R),Int(AH),R6.0
7880.3 1.000 (1.068 x 1.160 x 0.87)0.427 0.950 3458.2
6564.8 0.5540 3636.9 7880.3 1.00 1.083 0.427 0.950 3458.2
EnergyGaugeTM DCA Form 600A-2004R EnergyGauge®/FIaRES'2004R FLRCSB v4.5.2
FORM 600A-2004R EnergyGauge®4.5.2
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT#:
BASE g AS-BUILT
WATER HEATING
Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total
Bedrooms Volume Bedrooms Ratio Multiplier
2 2460.00 4920.0 40.0 0.92 2 1.00 2460.00 1.00 4920.0
As-Built Total: 4920.0
CODE COMPLIANCE STATUS
BASE AS-BUILT
Cooling + Heating + Hot Water = Total Cooling + Heating + Hot Water = Total
Points Points Points Points Points Points Points Points
9223 3637 4920 17780 7362 3458 4920 15740
PASS
yp4 THE STAI.. c
� a
r,I,CO WE �yS
EnergyGaugeTM DCA Form 600A-2004R EnergyGauge®/FlaRES'2004R FLRCSB v4.5.2
FORM 600A-2004R EnergyGauge®4.5.2
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT#:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS SECTION REQUIREMENT FOR EACH PRACTICE CHECK
Exterior Windows&Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft.window area; .5 cfm/sq.ft._door area
Exterior&Adjacent Walls 606.1.ABC.1.2.1 Caulk,gasket,weatherstrip or seal between:windows/doors&frames,surrounding wall;
foundation&wall sole or sill plate;joints between exterior wall panels at corners;utility
penetrations;between wall panels&top/bottom plates; between walls and floor.
EXCEPTION:Frame walls where a continuous infiltration barrier is installed that extends
from,and is sealed to,the foundation to the top plate.
Floors 606.1.ABC.1.2.2 Penetrations/openings>1/8"sealed unless backed by truss or joint members.
EXCEPTION:Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter,penetrations and seams.
Ceilings 606.1.ABC.1.2.3 Between walls&ceilings;penetrations of ceiling plane of top floor;around shafts,chases,
soffits,chimneys,cabinets sealed to continuous air barrier;gaps in gyp board&top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter at enetrations and seams.
Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations,sealed;or Type IC or non-IC rated,installed inside a
sealed box with 1/2"clearance&3"from insulation;or Type IC rated with<2.0 cfm from
conditioned space tested.
Multi-sto Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavi between floors.
Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors,dampers;combustion space heaters comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS SECTION REQUIREMENTS CHECK
Water Heaters 1 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2.Switch or clearly marked cir
breaker electric or cutoff(gas)must be rovided.External or built-in heat trap required.
Swimming Pools&Spas 612.1 Spas&heated pools must have covers(except solar heated). Non-commercial pools
must have a pump timer.Gas spa&pool heaters must have a minimum thermal
efficient of 78 . __
Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically
attached,sealed,insulated,and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics:R-6 min. insulation.
HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system.
Insulation 604.1,602.1 Ceilings-Min.R-19.Common walls-Frame R-11 or CBS R-3 both sides.
Common ceiling&floors R-1 1.
EnergyGaugeTm DCA Form 600A-2004R EnergyGauge®/FIaRES'2004R FLRCSB v4.5.2
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* =88.0
The higher the score,the more efficient the home.
1. New construction or existing New — 12. Cooling systems
2. Single family or multi-family Multi-family — a. Central Unit Cap:28.8 kBtu/hr
3. Number of units,if multi-family 4 — SEER: 13.00
4. Number of Bedrooms 2 _ b.N/A
5. Is this a worst case? Yes _
6. Conditioned floor area(ft2) 1531 ft2 _ c. N/A
7. Glass type'and area:(Label reqd.by 13-104.4.5 if not default)
a. U-factor: Description Area 13. Heating systems
(or Single or Double DEFAULT) 7a(Sngle Default)127.0 ft2 _ a. Electric Heat Pump Cap:27.8 kBtu/hr
b. SHGC: HSPF:8.00 _
(or Clear or Tint DEFAULT) 7b. (Clear) 127.0 ft2 _ b. N/A _
8. Floor types
a. Slab-On-Grade Edge Insulation R-O.0, 134.0(p)ft _ c. N/A _
b. Raised Wood,Post or Pier R=11.0, 124.0ft2
c. N/A _ 14. Hot water systems
9. Wall types a. Electric Resistance Cap:40.0 gallons _
a. Concrete,Int Insul,Exterior R=4.1,789.0 ft2 _ EF:0.92 _
b. Concrete,Int Insul,Adjacent R=4.1, 1400.0 ft2 _ b. N/A _
c. N/A
d. N/A c. Conservation credits _
e. N/A _ (HR-Heat recovery,Solar
10. Ceiling types DHP-Dedicated heat pump)
a. Under Attic R=30.0,878.0 ft2 _ 15. HVAC credits PT,
b. N/A _ (CF-Ceiling fan,CV-Cross ventilation,
c. N/A _ HF-Whole house fan,
11. Ducts PT-Programmable Thermostat,
a. Sup:Unc. Ret:Con. AH(Sealed):Interior Sup.R=6.0, 150.0 ft _ MZ-C-Multizone cooling,
b.N/A MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building ztir sT
Construction through the above energy saving features which will be installed(or exceeded)
in this home before final ' .Otherwise,a new EPL Display Card will be completed � .,'' �+
based on installed Code pl nt eatures.
Builder Signature: Date: f
Address of New Home: 3 City/FL Zip:2k�
*NOTE: The home's estimated energy performance score is only available through the FLA/RES computer program.
This is not a Building Energy Rating. If your score is 80 or greater(or 86 for a US EPA/DOE EnergyStardesignation),
your home may qualms for energy efficiency mortgage(EEM) incentives ifyou obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site at www.fsec.ucf edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building
Construction, contact the Department of Community Affairs at 850/487-1824.
I Predominant glass type.For actual glass type and areas,see Summer&Winter Glass out pit on ages 2&4.
EnergyGauge®(Version:FLRCSB p v4.5.2)
• MAR-19-2087 11:25 SIMPSON MECHANICAL 813 558 8578 P.16
- Wrightsvft� . Load Short Form J: MARTINIQUE-1531 S....
Entire House a:1R 00s
By; TRH
SIMPSON MECHANICAL
For: U.S. HOMES HOutside db(°F) I 92 g Gig Infiltratio :
Method Simplified
Inside db(°F) 70 75 Construction quality Average
Design TD(°F) 30 17 Fireplaces g
Daily range - L 0
Inside humidity(%) - 60
Moisture difference(grub) _ 52
HEATING EQUIPMENT COOLING EQUIP? PVT
Make Carrier Make Carrier
Trade Base 13 Puron HP Trade Base 13 Puron HP
Model 25HBA33OA30 Cond 25HBA33OA30
Coil FY4ANF030
Efficiency 8.3 HSPF
Efficiency
Heating input 13;BEER
Heating output Sensible cooling .2:1570 Btuh
P 31800 Btuh @ 47°F Latent cooling ..:734 Btuh
Temperature rise 29 °F Total cooling
Actual air flow 1000 cfm Actual air flow ?9000 Btuh
Air flow factor 0.044 cfm/Btuh Air flow factor .l 51 cfm
Staticpressure 0.051 cfm/Btuh
0.00 in H2O Static pressure 0!00 in H2O
Space thermostat Load sensible heat ratio 0,84
ROOM NAME Area Htg load Cig load Htg AVF': Cig AVF
(ft ) (Btuh) (Btuh) (cfm) (cfm)
FOYER 68 2777 1975 1'2 101
KITCHEN-NOOK 100 1834 1772 8'1' 91
DINING 160 1622 378 74
POWDER-STAIRS 131 1269 296 19
LIVING 297 7432 56 , 15
STAIRS-HALL 102 446 511 375 7b 1 32t 262
MASTER B.R. 23919
MASTER BATH 3206 4478 141 230
FLEX ROOM 58 195 173 9: , 9
HALL BATH 146 686 571 30 29
B.R.#2 2 58 195 173 ,9 9
174 3025 4180 13 215
8oldypl/a valoea hays been manually oVerrldden
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
wr1ghtscft RiqHl-suiteRealdeMial6.o.loo 2007-Mar-19
Z,1Tornny HVAC1US1531MJe.rrp Calc v Meru O ernaIon a W 12:07:24
P#99 I
• I�
MAR-19-2007 11:25 SIMPSON MECHANICAL 813 558 8578 P. 17
Entire House 1531 22686 19482 1000 1000
Other equip loads 1059 614
Equip. oQ 0.97 RSM 19573
Latent cooling 3824
TOTALS 1531 23745 23397 10c0 1000
QvWA a is values have peen manually ovenydden
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
wnghtsolF Right Suite Reeldenllel e.0.100 RSR43e13
ALXP zoo7•Mar•1$12 072
Z\Totmly M/ACUJ8t337 NUB,rrp CYIC=MJ8 Ortentatlon vy Ps 29a 2
Eiland Park Townhomes — Plan Review Comments
Below comments/highlights noted on master plan for Eiland Park Building by the Building
Official and Fire Marshal of the City of Zephyrhills.
1. Building shall comply with the applicable codes of Florida Fire Prevention Handbook
NFPA&the City of Zephyrhills. (Page 1)
2. Call about Extinguisher Placement(Page 1)
3. Inspection(s) required by Zephyrhills Fire Department(Page 1)
a. Fire Walls (screw/final)
b. Final
4. Building shall comply with all applicable City of Zephyrhills Ordinance (Page 1)
5. Finish floor elevation shall comply with engineered design and/or City of Zephyrhills
Ordinance (Page 1). A minimum 8" above road elevation.
6. Tie-in survey required before pre-slab inspection to show elevation.
7. Compaction test required if 24" of fill is brought in at any one place.
8. All setbacks shall be met.
9. Return air in all bedrooms. F.B.C. M1620.4
10. All water heaters shall have a thermal expansion control device installed per F.B.C.
plumbing 607.3.
11. Ground mounted A/C units shall be anchored per F.B.C. M1307.3.1
12. Lot shall be graded as to comply with 401.3 of the F.B.C.
13. Drainage Plan Requirements must be made: Ordinance#974-07, Section 6.
14. Smoke alarms to be installed per code 313.1 of the F.B.C.
15. All glazing requirements to be met per code 308.4 of the F.B.C.
16. Building shall comply with all applicable building, electrical, plumbing and mechanical
codes (Page 1)
17. Egress Note— Highlighted: Each bedroom must have one window that complies with
egress codes per code 311 of the F.B.C., if there is no access to exterior through a
door. The window must have a maximum sill height of 44" above finished floor line
of that particular room. (Sheet 1 A, 1 B, 1 C).
18. Alt. Fire Wall Detail at Common Wall — Highlighted: Be aware of the requirements
for fire caulk; fire resistant OSB sheathing; GYP Panels, Separation wall in roof
system. (Sheet S3).
19. Stencil firewall in attic area, both sides in several areas. "Firewall-do not penetrate"
(Sheet S6)
REV1E�""' -r y Ai rT , T1 r' �Wt PTXWITHA7L�.
TILLT J
CITY OF ZEPHYRU.ILLS ORDINANCES
F.F.E. — Finished Floor Elevation
F.B.C. — Florida Building Code
R.O.W. — Right of Way REVIEW DATE, I I ' —07
CITY OF ZEPI-_(RHILLS
PLANS EXAMINER�.,.L
L k