Loading...
HomeMy WebLinkAbout08-7466 (2) !CITY OFZEPHYRHILLS CITY OF 5335-'8TH STREET (813)780-0020 7466 'BUILDING PERMIT sl fmK-t x. Permit Number: 7466 Permit Type: COMMERCIAL Address: 39450 SOUTH AVE Class of Work: NEW C0NST/C0MM ZEPHYRHILLS, FL. Proposed Use: COMMERCIAL Township; Range: Book: Square Feet: Lot(s): Block: Section: Subdivision:Est. Value: Subdivision: CITY OF ZEPHYRHILLS Improv. Cost: 2,713,6O9.17 Parcel Number: 13-26-21-owo-00100 0000 Date Issued: , . ... Total Fees: Name: CITY OF ZEPHYRHILLS Amount Paid: Address: 3940 SOUTH AVE Date Paid: ZEPHYRHILLS, FL. 33542 Phone: Work Desc: INSTALLATION OFT HANGER- FEE WAIVED-CITY PROPERTY CARR'S CONSTRUCTION SERVICESINC FOV n OTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c)when extra inspection trips are necessary due to any one of the following reasons: a)wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d)work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." NTRACTOR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 02-04-'_08 21:27 FROM-Zephyrhills Airport 813780@032 ;T_. =._ T-242 P002/002 F-026 fi L4 •c o c ,: � �o n�-t c�a� - 0 � o � aZao � o $ e�� � gN� N O � --. 4g40y4 OOOoOq O� ?�� ~ b� -------- 1 ! i1 000� AOAn ova ? ny V ! m o o Q Q Q �y O A * Q C1 �• cc`��� �1 `� N rn 1 3 O `' ^ :rte O ---=— w o C3'O CnmU ,cai� ZO4nnoo �o O y o► b b to cftn•. � j 1 A A A �`.'� O O Q w j A ti O Q• _ C'� . O 1 4 q 4 Q ee • `O o N T� ` a C � Z � y H bti Z- a' v 2 A a 1 0 N• ti O n C zCO • !e S� A I Y, ^ \ Ji // \I / � / / JJJ it I -�� / \ / / I N a //J ,/ \ b � .o <\ x \ \ / X f(. / \ •a ( \ c ? \\\\\ ___ O o �aaaapo Tg�S�a 5 � 1 taL-� 4- - V -:� I -V. V - a I L Yo + tsa �4h tc� l " - $2yy $ice �] " III � u �y YiR tt mam 6c- c�a $sty-�a M i /+ y Fi I P '� ; 1ilo e 9ZO-3 Z00/t00d Zf,3-,L = ZE@@08LE18 ;Jod.ztj sTTru daZ-WOa3 LZ:tZ 80,-$0-Z@ Pasco County Property Appraiser- Legal Description for: 13-26-21-0000-00100-0080 Page 1 of 1 welcome : Records Search : Parcel Details : Legal Description Legal Description 13-26-21-0000-00100-0080 Assessed in Section 13, Township 26 South, Range 21 East of Pasco County, Florida THAT PORTION OF FOLLOWING DESC PARCEL LYING WITHIN IN SEC 13: COM AT SW COR OF SEC 12 TH N89 DEG 54'37"E ALG SOUTH LN OF SEC 12 3219.83 FT TH S42DEG 09DEG 14'E 8.47 FT FOR POB TH N43EG 54'30"E 265.29 FT TH S47DEG 09'31"E 155.52 FT TH S43DEG 54'30"W 278.89 FT TH N42DEG 09'14"W 155.86 FT TO POB SUBJ TO INGRESS/EGRESS ESMT OVER WEST 40 FT THEREOF TOG WITH INGRESS/EGRESS ESMT OVER WLY 40 FT OF PCLS A B & C; AKA PARCEL D OR 139 PG 137 Please be advised that our legal descriptions are for assessment purposes only, and are not intended for use in legal conveyances. Pasco County Property Appraiser Page Layout Modified: 12/6/2007 9:18:55 AM The Local Time Is: 10/16/2008 3:50:14 PM http://appraiser.pascogov.com/search/legal.aspx?parcel=2126130000001000080&cache=... 10/16/2008 Pasco County Parcel: 12-26-21-0000-04900-0100 001 Page 1 of 1 Search,Ag�in Show Map Building Schematic Unavailable Estimate Taxes Frequently Asked Questions Other Agency Data*- Tax Collector School Board Supervisor of Elections Data Current as Of: Weekly Archive - Saturday, October 04, 2008 Parcel ID 1 12-26-21-0000-04900-0100 (Card: 001 of 001) Classification II 89 - Other Municipal Mailing Address Property Value CITY OF ZEPHYRHILLS Ag Land $0 5335 8TH ST Land $27,196 ZEPHYRHILLS, FL 335424312 Bu Physical Address Extra Features $0 $0 Physical Address N/A Market Value $27,196 Legal Description (First 4 Lines) Assessed (Save Our Homes) $0 THAT PORTION OF FOLLOWING DESC PARCEL LYING WITHIN IN SEC 12: Taxable Value $0 COM AT SW COR OF SEC 12 TH N89 DEG 54'37"E ALG SOUTH LN OF Land Detail (Card: 001 of 001) Line Use IDescriptionhi Zoning Units H Type Price Condition Value* 1 8900 MUNICIPAL OAPs 12,000.00 II $1.42 1.00 $17,040 2 8900 MUNICIPAL OAPs 15,388.00 II $0.66 1.00 $10,156 Additional Land Information Acres 0.63 Tax Area 3OZH FEMA Code 0 Commercial Codell IZAPMAA Building Information (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line Description Year Units Value No Extra Features Sales History Previous Owner II N/A Year Month lh Book/Page Type Amount 1947 05 0139/0137 IIQC $0 Search Again Show Map Building Schematic Unavailable Estimate Taxes Frequently Asked Questions Other Agency Data: Tax Collector School Board Supervisor of Elections http://appraiser.pascogov.com/search/parcel.aspx?sec=12&twn=26&rng=21&sbb=0000&... 10/16/2008 ' D yr • c_ �,�� ill I II 9�l� t City of Zephyrhills: Building Department Phone: (813)-780-0020 Fax: (813)-780-0021 TO: Darryl FROM: Jackie { FAX#:813-715-0824 FAX#: { DATE:10-16-08 # OF PAGES including cover sheet: 4 { { { { MESSAGE: { You spoke with Steve Jones and he told me to fax over a release for power. We need a final { release of power given by City of Zephyrhills for hanger terminals located at 39450 South { Ave permit# 7466 (there are 10 terminals and all 10 where inspected)but we only want to { release power for 7 terminals right now the other three will be turned on when we have { terminals leased out. They will be under address 39450 South Ave: { Terminal 1 { { Terminal 2 { Terminal 3 { Terminal 4 { Terminal 5 Terminal 6 Terminal 7 { Any questions contact us at 813-780-0020 my name is Jackie and my ext. is #3513. { Thanks Jackie Map - Pasco County Property Appraiser Page 1 of 1 Pasco County, Florida i-3 miles M of"2ephyrtittls 12 26 21 0000 04900'0040 22621 0000 04000 0000 122621 DODO 04600 0000 / IWhen I click on the map: 122021 0000 04600 0100 r Quick Info Y„ le Full Info* r J Zoom In 1.5x Choose Layers: Parcel Lines(Black) , 1100O t00 8O Parcel Labels(Automatic) Street Names(Automatic) 1 2007 1 ft-Color Select Additional Layer Select Grouping 132621 0000 00100 0000 Image Size / Quality: 0000 (Quality applies if imagery is selected) Low Quality(Fast/]PEG)°t Links of Interest: Recent Sales in this area , Search for property in Pasco Map Search 670 Feet MapIC)#4289021 Street name information is maintained by the Pasco County BOCC GIS Department. http://maps.pascogov.com/maps/showmap.asp?Name=PascoMap_New&mdi=4289021&... 10/16/2008 813-780-0020 City of Zephyrhills t-ermlt Hppiicatwti - Building Department 1fI4; Date Received Phone Contact for Permitting III 11111 III 111111 11111 11111111 IiFFFITI UIIIIIIIIIIIII 1111 Owner's Name , (� �P t1 e'ir owncr Pno. �' I Owner's Address 53 Owner Phone Number Fee Simple Titleholder Name $6'w-e- �-J a 6U� Owner Phone Number S3 ' t.(1 s . 7_ ��f1 Fee Simple Titleholder Address JOB ADDRESS 3 G S a cc t- 2:1 I F LOT# I SUBDIVISION PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR e ADD/ALT = SIGN = MOVE = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR COMM = OTHER TYPE OF CONSTRUCTION = BLOCK = FRAME = STEEL = OTHER F- I �D GC ' DESCRIPTION OF WORK ZQ - ,t�( 1S �-� �� �/ '�"" �� �v(\ u6'i �I«r'\.J BUILDING SIZE 2 3 + c L/&" SQ FOOTAGE IQ v HEIGHT I tl BUILDING 13 t C� ( VALUATION OF TOTAL CONSTRUCTION = ELECTRICAL $ 19 / AMP SERVICE 0 PROGRESS ENERGY Q W.R.E.C. = PLUMBING $ = MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION LII GAS = ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS I FLOOD ZONE AREA =YES =NO BUILDER /' COMPANY I C4`L^ SIGNATURE (���^— REGISTERED Y/ N FEE CUR ENT Y/N .3 / Address 2_ �^ -J U�Lti'�? �/�S a ? v) License# F c 6Zo U b 4"b I ELECTRICIAN COMPANY SIGNATURE / REGISTERED Y/ FEE CURRENT Y/N , AddressL .a i License# /5'ol267!✓ I PLUMBER I COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y/N Address I I License# MECHANICAL I COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT Y/N Address License# I OTHER I COMPANY SIGNATURE REGISTERED I Y/ N FEE CURRENT I Y/N Address I License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$5000) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for,compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired d contraictor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone"V" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent the diti If use of fill fouperm adversely issued under the,acent attached permit properties, a application, for lots less than violating (1) the conditions of the building p acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise understand that a separate permit ay be equiired for is I i faith d info rm the owner ofm conditions electr electrical forth this affidavit prior to commencing construction. in the on. A plumbing, signs, wells, pools, air conditioning, to roceeder with the work and not as authority tto dviolate, cancel, alter, or permit issued shall be construed to be a license proceed te set aside any provisions of the technical codes, nor sohall issuance of a permit prevent r violations of any codes. Every tperm t issued ed shall l become invalid requiring a correction of errors in plans, construct unless the work authorized by such permit is commenced of six(6) n montx months of hsafter the time the issuance, or if work commenced. An extension orized by the permit is suspended or abandoned for a period ( ) ninety days and will demonstrate may be requested, in writing,e iom the If work Building ceases forininety(90)period consecutive days, the job isOcons considered abandoned. justifiable cause for the extension. WA RNING TO OWNER: YOUR FAILURE TO RECORD RTOTICE OF INTO END TO OBTAIN F NANC NG CONSULT MMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPEY IF YOU OF COMMENCEMENT. WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE FLORIDA JURAT(F.S. 117.03) CONTRACTOR OWNER OR AGENT Subscribed and swo 7�fT1e�efo me this Subscribed and sworn to(or affirmed)before me this UL by who is p rsonally known to me or hasas Identification. hasveWho is personally known to me or Identlfcroduced ation Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (813) 780-0041 Kerry Barnett Fax (813) 780-0044 February 4, 2008 I have reviewed and approved the plans for a construction of new Group III T-hangars located at the Zephyrhills Airport. I have attached the comments for the plan approval. If there are any questions please contact my office at 813-780-0041. 1. Building construction shall be in compliance with the 2004 Florida Fire Prevention Code and all applicable NFPA standards and codes. 2. Fire hydrant shall be located within 350' of each hangar 3. Certified fire extinguishers shall be located within each space in accordance with NFPA 10. 4. An egress door shall be installed in each space and shall swing outward. (hangar aircraft door excluded) 5. There shall be 75' clearance around all sides of each hangar 6. No fuel transfer or fueling, welding, torch cutting, doping or spray painting shall be conducted inside the hangar. If so, the hangar shall be protected with a fire suppression system. Inspections Required 1. Building Final NOTE: FEES WAIVED DUE TO PROJECT BEING A CITY OWNED AND OPERATED STRUCTURE. Page 1 of 1 Jacq�ueMne Boges From: Trina Sweet Sent: Thursday, February 07, 2008 4:23 PM To: Jacqueline Boges Subject: t-hangar permit Jackie, I understand that you have requested written confirmation that the t-hangar project, for which Carr Contracting is applying for a permit, is indeed a city project located on airport property. These projects are typically exempt from all application and permitting fees. Please let me know if you require any additional information. Thanks, Trina Sweet Airport Manager Zephyrhills Municipal Airport 2/8/2008 T-Hangar Curbing- Performance Test ` 3 PURPOSE: This test is to be conducted to determine if a sealed 6" metal curb will satisfy the NFPA 409 Criteria for Group III Hangars, specifically nested T-Hangars. CONSTRUCTED CONDITION: Building consists of a Pre-Engineered Metal Building that utilizes an L-shaped metal angle as the 6" curb. The curb is fastened to the floor with metal fasteners. The recommended installation is to place a continuous bead of a fuel resistant caulking under the angle so that the floor fastener is between the two beads, but an alternate method is to seal the angle along the outside edge and seal each floor fastener. All vertical joints are sealed as well in both installation methods. The building slab is constructed with a slope to the outside of the structure so that spilled liquids do not pool inside the building. The building slab slope is%2%; falling 1%" over 24'. INTENDED USE OF STRUCTURE: The nested T-Hangars are to be used for the storage of private aircraft. The size of the hangar units limits the aircraft types to certain Group 1 aircraft with minimally-sized fuel tanks. TEST APPROACH &ASSUMPTIONS: Test will be conducted to imitate a sudden rupture of a stored aircraft's fuel tank. This is considered the more severe instance as the sloped floor would account for any slow leaks that may be present, taking any excess fuel to the outside of the hangar space. Assumptions are: • Aircraft is parked in its normal position inside the unit • Fuel Tanks in the aircraft are full (approximately 30 gallons per tank) • A tank is ruptured in a manner that directs the fuel away from the door, toward the walls TEST PROCEDURE: 1) Identify the location of the"Leak" 2) Hold a hose above the slab (Approximately 30"—36") 3) Turn on the hose, allowing water to splatter and run on floor. 4) Hold the hose in place for over 2 minutes assuming a flow rate of 15 gallons a minute. 5) Observe for leaks in the curbing. Observations will be made on both sides of the wall. 6) Identify any leak locations and determine if caulk had failed or if it was misapplied. TEST CERTIFICATION The Test was conducted in tenter part of the Hangar on November 17th 2008 at Zephyrhills Municipal Airport and leaks/ no leaks were observed. NO L l�/LK 5 - L /nJ 1, T Signed S Date 1 '1 7 -v -r — M v,r 1 A44R' ►LIS r-t !L c�vr OaDfL, T-Hangar Curbing Performance Test I PURPOSE: This test is to be conducted to determine if a sealed 6" metal curb will satisfy the NFPA 409 Criteria for Group III Hangars, specifically nested T-Hangars. CONSTRUCTED CONDITION: Building consists of a Pre-Engineered Metal Building that utilizes an L-shaped metal angle as the 6" curb. The curb is fastened to the floor with metal fasteners. The recommended installation is to place a continuous bead of a fuel resistant caulking under the angle so that the floor fastener is between the two beads, but an alternate method is to seal the angle along the outside edge and seal each floor fastener. All vertical joints are sealed as well in both installation methods. The building slab is constructed with a slope to the outside of the structure so that spilled liquids do not pool inside the building. The building slab slope is%%; falling 1%z" over 24'. INTENDED USE OF STRUCTURE: The nested T-Hangars are to be used for the storage of private aircraft. The size of the hangar units limits the aircraft types to certain Group 1 aircraft with minimally-sized fuel tanks. TEST APPROACH &ASSUMPTIONS: Test will be conducted to imitate a sudden rupture of a stored aircraft's fuel tank. This is considered the more severe instance as the sloped floor would account for any slow leaks that may be present, taking any excess fuel to the outside of the hangar space. Assumptions are: • Aircraft is parked in its normal position inside the unit • Fuel Tanks in the aircraft are full (approximately 30 gallons per tank) • A tank is ruptured in a manner that directs the fuel away from the door, toward the walls TEST PROCEDURE: 1) Place a 55-Gallon Drum in the back of a Pickup Truck 2) Cut out a portion of the top of the drum 3) Fill the drum with approximately 30 gallons of water 4) Back truck into the unit so that the back of the truck is located near the approximate location of the fuel tank. 5) Turn the drum over so that the water rushes out onto the slab, replicating the tank rupture 6) Observe for leaks in the curbing. Observations will be made on both sides of the wall. 7) Identify any leak locations and determine if caulk had failed or if it was misapplied. TEST CERTIFICATION The Test was condycted in the front part of the Hangar on November 14th, 2008 at Zephyrhills Municipal Airport and leaks/ 7 no leaks were observed. A� -�.rL. I� 7 Zcr)T _ Nv (,64K6 CO GuRF3i.�6 A � Alvve_ Signed t' Date is —i4(2 ) — MA, >4s TL-1!t T-Hangar Curbing' Perforrtanee Testz PURPOSE: This test is to be conducted to determine if a sealed 6" metal curb will satisfy the NFPA 409 Criteria for Group III Hangars, specifically nested T-Hangars. CONSTRUCTED CONDITION: Building consists of a Pre-Engineered Metal Building that utilizes an L-shaped metal angle as the 6" curb. The curb is fastened to the floor with metal fasteners. The recommended installation is to place a continuous bead of a fuel resistant caulking under the angle so that the floor fastener is between the two beads, but an alternate method is to seal the angle along the outside edge and seal each floor fastener. All vertical joints are sealed as well in both installation methods. The building slab is constructed with a slope to the outside of the structure so that spilled liquids do not pool inside the building. The building slab slope is%2%; falling 1%z" over 24'. INTENDED USE OF STRUCTURE: The nested T-Hangars are to be used for the storage of private aircraft. The size of the hangar units limits the aircraft types to certain Group 1 aircraft with minimally-sized fuel tanks. TEST APPROACH &ASSUMPTIONS: Test will be conducted to imitate a sudden rupture of a stored aircraft's fuel tank. This is considered the more severe instance as the sloped floor would account for any slow leaks that may be present,taking any excess fuel to the outside of the hangar space. Assumptions are: • Aircraft is parked in its normal position inside the unit • Fuel Tanks in the aircraft are full (approximately 30 gallons per tank) • A tank is ruptured in a manner that directs the fuel away from the door, toward the walls TEST PROCEDURE: 1) Place a 55-Gallon Drum in the back of a Pickup Truck 2) Cut out a portion of the top of the drum 3) Fill the drum with approximately 30 gallons of water 4) Back truck into the unit so that the back of the truck is located near the approximate location of the fuel tank. 5) Turn the drum over so that the water rushes out onto the slab, replicating the tank rupture 6) Observe for leaks in the curbing. Observations will be made on both sides of the wall. 7) Identify any leak locations and determine if caulk had failed or if it was misapplied. TEST CERTIFICATION The Test wws conducted in the rear part of the Hangar on November 14th 2008 at Zephyrhills Municipal Airport and leaks/ no leaks were observed. 2. rfvca-►-� ) (. r5,4lcg —Joh T3 *b BZL Signed ,'%C 4!%- Date /1 ' 1�-UL) L borLr7��,2