Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
08-7630
CITY OF ZEPHYRHILLS 5335-8Th STREET (813)780-0020 7630 FIRE ALARM SYSTEM PERMIT Permit Number: 7630 Address: 6938 MEDICAL VIEW LN Permit Type: FIRE ALARM SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: COMMERCIAL Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 02-26-21-0290-00000-0070 Improv. Cost: 4,064.36 Date Issued: 3/18/2008 Name: LENDALL, KNIGHT& CHRISTINA Total Fees: 150.00 Address: 4901 SEMINARY RD Amount Paid: 150.00 ALEXANDER VI 22311 Date Paid: 3/18/2008 Phone: Work Desc: INSTALLATION OF NEW FIRE ALARM SYSTEM fl? A TOTAL SOLUTION,INC FIRE ALARM 50.00 FIRE PLAN REVIEW FEES 50.00 FIRE INSPECTION FEES 50.00 hN j ) fit 7S8 \\\O\ __ ___ ____________ FIRE ACCEPTANCE Final FIRE ELEVATOR RECALL Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." a., CONTRACTOR SIGNATURE I IC R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- Fire Marshal Office- 813-780-0041 EP `ZEP.HYRHILLS FIRE DEPARTMENT _ tTE 6907.Dairy Road,Zephyrhills, FL 33542 Fire Chief Keith Williams---_ Bus (813)780=.0041 Fax (813)780-0044 FIRE SERVICE USER FEES Occupancy No.: /, /�� . Plan No.: Contractor. Business Name: Billing.Address: 3 Business Address: Business Phone No.: Billing Phone'No.: - -- 4 Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE 8 Site Plan N/C Annual N/C Sprinkler $50 1st Alarm WC Muth -amiy/Commercial .06 sf 1st Re-inspection WC Standpipes $50 2nd Alarm N/C (Minimum Charge$25.00 2nd Re-inspection $100 Fire Pump $50 3rd Alarm WC fl Plan Revisions DBL 3rd Re-inspection $250 Hoods 4th Alarm $100 4th Re-Inspection $500 FueAlann 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until LP Gas $50 6th Alarm $200 0-25 Heads $50 violations corrected) Natural Gas $50 NON COMPUANCE $150 26 phis Heads $100 SPRINKLER SYSTEMS Fuel Tanks- pertank $50 STANDPIPE SYSTEM Hydro Undergrounds $45 Sparklers $100 Per Riser $50 Hydrostatic Test $65 per sysonn Fire Works $500 FIRE PUMP Acceptance Test $45 per syst n Camp Fire $25 Per Pump $100 Hydrant Flow $75 Controlled Bum $100 FIRE ALARM SYSTEM Hood/Duct $50 0-25 Devices FIRE ALARM SYSTE Place of Assembly $50 Annual 26 plus Devices $100 iN System Acceptance Fire Protection $25 SUPPRESSION SYSTEMS Recall Acceptance Flammable Application $50 Annual Wet $50 OTHER Waste Tire Storage $50 Annual Dry $50 Fire WaiSmoke Wall $15 pervaii Generator<KW $100 CO2 $50 LP Gas $25 per tank Generator>30 KW 150 Other $50 Natural Gas $25 per sys>em Bio-Hazard Waste $100 Annual KITCHEN EXHAUST Fumigation Tenting $50 Hood/Ducts $50 Terd 10X10'or greater $15 pent Torch Pot/Applied $50 OTHER Fire Pump $45 Haz Materials $100 Annual LP Installation pertank $50 Fire Suppression $30 Fuel Tank Installation $50 System Acceptance (Per Tank) $50 Exhaust Hood/Duct. $30 ❑Natural Gas Installation $50 Re-inspection DBL (Per System) (other than annual) Spray Booth $50 Inspection scheduled DBL and cancelled less than 24 hours Construction lnsp. N/C Emergency Vehicle Ac i $50 FALSE ALARM PLANS TOTAL ' INSPECTION TOTAL PERMIT TOTAL TOTAL GRAND TOTAL t Q Comments: Date: Ins%ctor Pasco County Parcel: 02-26-21-0290-00000-0070 001 Page 1 of 1 S__earch Again Show Map Generalized Building Schematic Estimate Taxes Frequently Asked Questions Other Agency Data: Tax_Coll_ector School Board Supervisor of Elections Data Current as Of: Weekly Archive - Friday, February 22, 2008 Parcel ID 02-26-21-0290-00000-0070 (Card: 001 of 001) Classification 19 - Professional Service Building Mailing Address Assessment (totals) KNIGHT LENDALL S&CHRISTINA M Ag Land $0 4901 SEMINARY RD APT 1528 Land $95,731 ALEXANDRIA,VA 223111833 Building $505,433 Physical Address - See All 2 addresses (First Shown) Extra Features $8,682 6938 MEDICAL VIEW LN ZEPHYRHILLS, FL 33542-6602 Total Assessment $609,846 Legal Description (First 4 Lines) Save Our Homes $0 DAUGHTERY ROAD PROFESSIONAL CENTER III PB 53 PG 024 Taxable Value $609,846 LOT 7 OR 6803 PG 1376 Land Detail (Card: 001 of 001) Line if Use IDescriptiolil Zoning if Units if Type if Price Condition Value 1 if 1900 if PROF.BLDG if 00OP I 12,000.00 if SF I $5.17 if 1.00 I $62,040 2 if 1900 if PROF.BLDG I 00OP I 11,780.00 I SF I $2.86 if 1.00 I $33,691 Additional Land Information Acres if 0.55 Tax Area if 30ZH FEMA Code if - Commerical Codeif PDRPIAA Building Information - Use 19 - Offices Professional or Medical (Card: 001 of 001) Year Built 2006 Stories 1.0 Exterior Wall 1 Concrete Block Stucco Exterior Wall 2 None Roof Structure Gable or Hip Roof Cover Asphalt or Composition Shingle Interior Wall 1 Drywall Interior Wall 2 None Flooring 1 VCT Flooring 2 None Fuel Electric Heat Forced Air- Ducted A/C Central Baths 4.0 Line I Description H Sq. Feet Repl. Cost New 1 BASH 4,500 if $517,500 2 if CAN H 104 I $3,565 Extra Features (Card: 001 of 001) Line Description Year Units Value 1 J PAV ASP 2006 8,520 $6,326 2 PAV CON 2006 1,450 $2,356 Sales History Previous Owner RYMAN KEVIN L&TAMMY L& Year Month Book/Page I Type Amount 2006 01 6803/ 1376 if WD $607,000 2003 09 5532 /0577 if WD $0 Search Again Show Map Generalized Building Schematic Estimate Taxes Frequently Asked Questions Other Agency Data: Tax Collector School Board Supervisor of Elections http://appraiser.pascogov.com/search/parcel.aspx?sec=02&twn=26&rng=21&sbb=0290&blk=00000&lot... 2/28/2008 Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (813) 780-0041 Kerry Barnett Fax (813) 780-0044 March 12, 2008 I have reviewed and approved the plans for a fire alarm system located at 6938 Medical View Ln. for the VA. I have attached the comments for the plan approval. If there are any questions please contact my office at 813-780-0041. 1. System to be installed in accordance to NFPA 72, 2007 edition. 2. Make sure batteries are dated and phone jacks are marked. 3. Provide a zone chart next to panel. 4. Smokes and pulls shall be addressable/labeled. 5. Add strobe outside of building on wall facing road. 6. Lock off and label breaker for fire alarm. 7. Copy of certificate of monitoring company at acceptance test. Inspections Required 1. Acceptance test 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Budding DepartmerR Date Received r/� -a?- co one Contact for Perm icing 7 /y - 19/ Owner's Name /\I1'5A1 LetuidRll 54('L.f1 f5 I'/1 f Owner Phone Number A Owners Address ' i -»:m Rr kd elc d 119 Owner Phone Number( /wv'/eI Fee Simple Titleholder Name �1 Owner Phone Number /V /► Fee Simple Titleholder Address /1 JOB ADDRESS 103 e / il e f/✓ L + ze /,/1 /IL. 3 r LOT# I SUBDIVISION ry PARCEL ID* 0? -l yC/ -© Q -Go 701 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED ® NEWCONSTR e ADD/ALT SIGN = MOVE DEMOLISH INSTALL REPAIR PROPOSED USE SFR COMM OTHER if TYPE OF CONSTRUCTION BLOCK [ J FRAME Q STEEL Q OTHER DESCRIPTION OF WORK I /i e vv r r e A/A<)fC /n S BUILDING SIZE C Q� SQ FOOTAGE / ( 78 J HEIGHT BUILDING $ VALUATION OF TOTAL CONSTRUCTION Q ELECTRICAL $ (/^ ' 3/ AMP SERVICE Q PROGRESS ENERGY Q WR.EC. PLUMBING $ 1� Q MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION Q GAS ROOFING [ J SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES =NO BUILDER '1//f? COMPANY SIGNATURE / REGISTERED Y N I FEE CURRENT N Address —_—� License# ELECTRICIAN i '✓ COMPANY SIGNATURE REGISTERED N FEE CURRENT Address ��'/// License# r PLUMBER 'j/ /� COMPANY IG SNATURE I ,I REGISTERED I Y/ N FEE CURRENT I Y/N Address License# MECHANICAL /,//O COMPANY J I SIGNATURE REGISTERED I Y/N j FEE CURRENT Y/N Address License# OTHER i1/%2 COMPANY SIGNATURE 7"' I REGISTERED I Y/N j FEE CURRENT Y/N N Address --� License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Sift Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Sift Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$5000) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with nolar¢ed letter from Owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the iwner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not property licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore,if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads,Wetland Areas and Environmentally Sensitive Lands,Wateul astewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V unless expressly permitted. - If the fill material is to be used in Flood Zone "A". it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning,gas,or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,after,or set aside any provisions of the technical codes,nor shag issuance of a perm prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is cormhenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the tine the work is commenced. An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BORE RECORDING YOUR NOTICE OF COMMENCEMENT FLORIDA,IURAT(F.S r�'7.0°3 o B�I OWNER OR AGTJ CONTRACTOR Subscribed and soon to(r► or rmed)bemire moths Subscribed and swan to(or affirmed)before me this 6'(-SIG' by VouC I.- r'f' Jo-4e"S by Vd,o s/are personally know/to me or has/have produced Who is/are personally known to me or has/have produced t c(.yi.$:' as identification. as identification. *;, ��� bpc Notary Public r ires DOW r 12 2010 Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped A TOTAL SOLUTION, INC 3531 KEYSTONE RD TARPON SPRINGS, FL 34688 FIRE ALARM LICENSE: EF0000441 LICENSE HOLDER: JOHN S. ROBINSON PHONE NUMBER: (727) 942-1993 PROJECT: P2717 VA MEDICAL OFFICE 6938 MEDICAL VIEW LN. ZEPHYRHILLS, FL. 33542 DESCRIPTION OF WORK FIRE ALARM SYSTEM APPROVED by wire Marshal of Zephyrhilis -pith ." ? is r"isle' with glan(s) Jobsite Information: FCPS-24FS6 / 8 Battery Calculation Regulated Load in Standb Number of Current Total Current Device Type Devices (Amps) (Amps) Main PC Board 1 X 0.065 = 0.065 Power Supervision Relays X 0.025 = 0 Auxiliary Current Draw X = 0 from TB4 Terminals 9&10 STANDBY LOAD = 0.065 Regulated Load in ALARM Number of Current Total Current Device Type Devices (Amps) (Amps) Main PC Board without AC 1 X 0.145 = 0.145 Power Supervision Relays X 0.025 = 0 Auxiliary Current Draw X = 0 from TB4 Terminals 9&10 NAC/Output#1 1 X 0.644 = 0.644 NAC/Output#2 X = 0 NAC/Output#3 X = 0 NAC/O ut#4 X = 0 ALARM LOAD = I 0.789 Battery Amp Hour Calculation Standby Load Required Standby Time Current(Amps) (Typically 24 or 60 Hours) 0.065 X 24 = 1.56 AH Alarm Load Required Alarm Time Current(Amps) (Typically 5 or 10 Minutes) 0.789 X 10 = 0.13 AH Sub Total Standby/Alarm Amp Hours 1.69 AH Multiply by the Derating Factor X 1.2 * Total Ampere Hours Required = 3 AH Derating Factor required to compensate for the non-linear discharge characteristic of a battery. A TOTAL SOLUTION.,1I INC . I ITotal Systems Integration. Installation. Sales. Design and Inspections Fire Alarm/Fire Sprinkler/Fire Hydrant/Security Alarm/Access Control/ CCTV(closed circuit TV)/Nurse Call and Intercom State Fire Sprinkler License#92353800012002 State Fire Alarm License#EF0000441 w-ww-.atotalsolution.com Northwind Property Management, LLC ONE CALL DOES!7 - 4901 Seminary Road Apt. 1528 Quote No: 7305 Alexandria, VA 22311 Date: 2/12/2008 Page: 1 of 3 Attention: Lendall/Christina Knight A Total Solution, Inc. is pleased to offer the following fire alarm system installation proposal at the location,VA Clinic - 6938 Medical View Lane 33.4'2 All equipment installed kiy ATS meets the NFPA 101 (2003), NFPA 72 (2002) standards and the Authority Having Jurisdiction The proposal is as follows; Quantity Equipment: 1 Fire/security control panel, manufactured by Bosch 1 120V Circuit Protector 2 Phone Line Surge Protector 1 Fire control Keypad station, Bosch 2 Fire Pull Station Double Action 5 Photo Electric Smoke Detector 5 Smoke Detector Base 4 Multi-Candela Audible Visual Device (White) 3 Visual Device Multi Can Strobe (White) The cost for this installation will be $4,064.36 . This price includes all parts (including cable, boxes, and hardware), labor, permits and state sales tax if applicable. The customer is responsible for providing a 120 volt dedicated circuit for the fire alarm system, Two dedicated telephone lines and necessary electrical boxes installed. The fire alarm system will have a one year warranty on parts and labor. The warranty will be voided if the system is found to be misused or abused and/or an act of nature occurs. Please allow 4 to 6 weeks for permiting. (if required) Permit fees are subject to change. We reserve the right to adjust our price if this occurs. 3531 KEYSTONE ROAD TARPON SPRINGS, FLORIDA 34688-7815 LOCAL(727)942-1993 CENTRAL FLORIDA 1-888-ATS-FIRE FAX(727)943-5919 A. TOTAL SOLUTION, Total Systems Integration. Installation_ Sales. Design and Inspections Fire Alarm/Fire Sprinkler/Fire Hydrant/Security Alarm/Access Control/ CCTV(closed circuit TV)/Nurse Call and Intercom State Fire Sprinkler License#92353800012002 State Fire Alarm License#EFO00044I n-ww-xv.atotalsolution.corn Northwind Property Management, LLC "ONE 0L-FOES TALL' 4901 Seminary Road Apt. 1528 Quote No: 7305 Date: 2/12/2008 Alexandria, VA 22311 Page: 2 of 3 This proposal is for the installation of a code compliant fire alarm system. This proposal includes smoke detection in all corridors and the equipment room. The customer is responsible for providing a 115 volt dedicated circuit. 3531 KEYSTONE ROAD TARPON SPRINGS, FLORIDA 34688-7815 LOCAL(727)942-1993 CENTRAL FLORIDA 1-888-ATS-FIRE FAX(727)943-5919 A TOTAL SOLUTION, INC . Total Systems Integration. Installation. Sales. Design and Inspections Fire Alarm/Fire Sprinkler/Fire Hydrant/Security Alarm/Access Control/ CCTV(closed circuit TV)/Nurse Call and Intercom State Fire Sprinkler License#92353800012002 State Fire Alarm License#EF000044I «w\v.atotalsolution.corn Northwind Property Management, LLC "ONE CALL DOES iT ALL., 4901 Seminary Road Apt. 1528 Quote No: 7305 Alexandria, VA 22311 Date: 2/12/2008 Page: 3 of 3 Installation Terms: The customer is responsible for all wall and/or ceiling repairs that may be necessary for fire alarm system access and installation purposes. ATS will be responsible for any drywall damage that could occur during this installation.When applicable the air conditioning contractor is responsible for the wiring of duct smoke detectors for system shut down purposes and the electrical contractor is responsible for the installation of the shunt trip devices when elevator shut down is required. If additional equipment is requested, that cost will be negotiated prior to the installation. Fire Alarm Monitoring ATS will provide monitoring of the alarm system for$32.00 per month (plus sales tax billed quarterly) Please initial below to have your fire alarm system connected to the central station for monitoring. Fire alarm monitoring requires two phone lines at the building. Customer Initials Installation Pa ment chedule: ,, / J2 10% Upon accept nce of contr ct. (P rmitting, es1i PE Seals) ^ "/0 JtJ 80% (Progress p ments) - Vyfien al electrical pre-wire has been completed for ch floor, p se or ilestone. O� D 10% Balen due after fi al insp tion accepted by the AHJ. � ��OrJ This proposal is valid for 30 days. If you should have any questions, please give me a call. Sincerely, Acceptance: Charlie Ragghianti Col-�r✓� OV 1 Director of Sales Customer Name (Please Print) Customer Signature Contract Amount $4,064.36 Date 3531 KEYSTONE ROAD TARPON SPRINGS, FLORIDA 34688-7815 LOCAL(727)942-1993 CENTRAL FLORIDA 1-888-ATS-FIRE FAX(727)943-5919 9 BOSCH Invented for life D7412G Control Panel ► Digital communicator with phone line monitor (loop or B0ScH ground start) ► Multiple telephone numbers,primary and duplicate paths with main and alternate destinations ► All reports within each of four route groups are programmable ► Optional dual phone line switcher monitors two phone lines• ra l ► Optional network interface module for two-way communication over Ethernet networks ► Automatic test and status reports ► Time windows for arming and open and close report ��.. suppression ► Programmable answering machine solution for remote programming on shared phone lines The D7412G Control Panel provides an integrated solution (NO)and or normally closed (NC) devices with end-of-line for Access Control, Security,and Fire Alarm system (EOL) resistor supervision. Each point is programmable for applications.The control panel is capable of monitoring fire,fire supervisory,or burglary applications. alarm points for intruder or fire alarms while operating user command centers and other outputs.The control panel System Response includes a communicator that reports events to selected • 31 custom point indexes,including fire supervisory PSTN or IP network destinations through four • Selectable point response time programmable route groups. Programming and accessory • Cross point compatibility • Fire alarm verification modules offer flexibility and beneficial features rarely found • Fire inspector's local test in other security control systems. • Watch mode The D7412G Control Panel provides eight on-board points, • Scheduled events(skeds) arm, disarm, bypass and up to 67 off-board points,64 relays,and two access control unbypass points,control relays,control authority levels, doors. Grant access from a Wiegand style card reader and control door access connected to:a D9210B Access Control Module,a request- to-enter or request-to-exit input,or a keypad. User Interface • Supervises up to eight command centers or keypads(up to 32 non-supervised command centers or keypads can Functions be used) • Custom command center text Programmable Outputs • Full function command menu including custom functions • 2 A alarm power at 12 VDC • Each user has authority by area and 16-character name • 1.4 A auxiliary power at 12 VDC • 14 custom authority levels control user's authority to • Four alarm output patterns change,add,delete passcodes or access control • Automatic bell test tokens/cards,disarm, bypass points,and initiate • Programmable bell shut-off timer system tests The D7412G Control Panel provides up to 75 individually identified points. Each point accommodates normally open • Adjustable brightness or volume for keypad display or provide a record of openings and closings without extra sounder communications costs. RPS operators can retrieve events Note At least one keypad per system is periodically using one phone call, rather than receiving recommended, several calls each day. When the control panel's event log reaches the storage limit,it can send a report to a receiver. Area Configurations Access events that you can store,view or print include: Area programming offers a wide selection of different • Access granted • No entry system configurations. Each area is assigned an account • Request-to-enter number to define annunciation, control, and reporting • Request-to-exit functions. Multiple areas can be linked to a shared area which is automatically controlled (hallway or lobby).Area Access Control arming can be conditional on other areas (master or • Custom door strike, point shunt and auto disarming associate), response by area • Logging options for:Access Granted, No Entry, User Passcodes Request-to-exit, and Request-to-enter • 14 panel-wide access levels with both manual and User passcodes contain three to six digits. Each user is scheduled control assigned one of 14 customized authority levels in each area. Passcodes can be restricted to operate only during certain Scheduled Events(Skeds) times.User names can contain up to 16 characters.The user The D7412G Control Panel's internal clock and calendar name can be viewed, printed, reported to a central station helps to operate individually scheduled events (skeds). in Modem Illa2 Communications format or retrieved with Skeds perform a specific function such as arm/disarm,relay Remote Programming(RPS)software. control,or point bypassing. The D7412G Control Panel offers: Security and Fire Detection • 40 scheduled events with up to 26 different functions The D7412G Control Panel provides eight on-board points, • 16 open or closing windows and up to 67 additional off-board points (depending on • Eight user windows model and expansion interfaces).Program individual points • Day-of-week,date-of-year, or holiday only schedules to monitor all types of burglar alarm,fire alarm,and • Four holiday schedules of 366 days each (leap year) supervision devices. Fire Test Communications When a user activates Fire Test Mode,the control panel The D7412G has four route groups. It can sort reports by suppresses all reports to the central station. Use a passcode at the keypad to activate Fire Test Mode.The priority and transmit reports to four route groups each of keypad and annunciator show all testing data.An automatic which has a programmable primary and backup destination, sensor reset feature saves time;you do not need to reset The D7412G is compatible with the D6600 NetCom the sensors manually.At the end of test,the keypad shows Communications System using a DX4020 Network Interface the number of untested points. Module. It has programmable anti-replay anti-substitution when using a DX4020. Programming,Diagnostics and Controls The Modem Illa2 Communications Format,available with Bosch receivers, adds reporting capabilities such as: Users can program all system functions on-site with a • Individual point numbers and text D5200 Programmer,or remotely through RPS.A • Opening or closing reports by area number, user programmable system passcode prevents unauthorized number, and user text remote programming. • Remote programming attempts The control panel accommodates up to four separate • Diagnostic reports telephone numbers for primary, alternate and backup receivers for automatic test reports. Event Log Storage,Viewing and Printing When resetting alarms,arming or disarming a combination All local and transmitted events(up to 1,000 total events) fire/burglary and/or access control system,the user is are stored in a log. The event log includes time, date and identified by name and number. event,with area, point and user number.You can view the event log from select keypads or remotely retrieve event information using RPS.With the printer interface module installed,the D7412G Control Panel allows the use of one on-site parallel printers.The Event Log and a local printer Certifications and Approvals Keypads D1260 Series K Keypads(01260,01260W,D1260R, D1260BLK,D1260B) UL Standards UL365,Police Station Burglar Alarm Units and Systems Ul609,Local Burglar Alarm Units and Systems Mod ��10-24-R Bell 24 V.25.4 cm(10 in.) UL864,Control Units for Fire-protective Signaling �� C900V2 Dialer Capture Module Sys- tems D125B Dual Class B Initiating Module UL985,Household Fire Warning System Units D127 Reversing Relay Module UL1023,Household Burglar-alarm System Units UL1076,Proprietary Burglar Alarm Units and Systems D129 Class A Initiating Module UL1610,Central-station Burglar-alarm Units D130 Auxiliary Relay Module UL1635,Digital Alarm Communicator System Units 0136 Plug-in Relay Approvals FCC:AJ9MLU-46532-AL-E 0185 Reverse Polarity Signaling Module Factory Mutual D192C Notification Appliance Circuit Module CSFM: D192G Notification Appliance • 7165-0801:123,Control Units-Non-high Rise Circuit Module • 7170-0801:175,Control Units-High Rise D8121A Derived Channel S.T.U.Five Zone(Non-UL) D8122 Derived Channel S.T.U.Five Zone(UL) D8125MUX Multiplex Bus Interface Installation/Configuration Notes 08125 POPEX Point Expander D8128D OctoPOPIT Eight Point Expander Compatible Products D8129 Octo-relay Module Keypads D1260 Series Keypads(D1260,D1260W,D1260R, D9127 Series POPIT Modules D1260BLK,D1260B) D9131A Printer and Parallel Interface Module 0720Series Keypads(D720,D720W,D720R,D720B) D9210BLC Access Control Interface Module D1255 Series Keypads(D1255,01255 W,D1255R, DS7432 Eight-input Remote Module D1255B,0125588) DS7457i Series Single Zone Multiplex Input Modules D1256 and D1256RB Fire Keypads DS7460i Two-input Module D1257 and D1257RB Remote Fire Alarm Annunciators DS7461i Single-input Multiplex Module D279A Independent Zone Control DS7465i Input and Output Module Detectors 00850 Series Outdoor TriTech Detectors DX4010i RS-232 Serial Interface Module MX250 Series Smoke Detectors DX4020 Network Interface Module MX775i Addressable PIR Detector Peripheral Hard- rvm4c Remote Video Module MX794i Long Range Multiplex PIR Detector ware MX934i Addressable PIR Detector Progtamnritg D5200 Series Programmers MX938i Addressable PIR Detector RPS or RPS-Lite Remote Programming Software ZX776Z PIR Detector Readers ARD-R10 iCLASS Mullion Reader ZX794Z Long Range PIR Detector ARD-R40 iCLASS Switchplate Reader ZX835 TriTech Microwave/PIR Detector ARD-RK40-09 iCLASS PIN Reader ZX935Z PIR Detector ARD-VSMART iCLASS Reader ZX938Z PIR Detector D8201/W Series Low-profile Readers ZX970 PIR/Microwave Detector D8203/W Series Mullion Proximity Readers Bosch conventional detectors include Blue Line,seis- D8223 Prox Pro Reader mic,PIR,TriTech PIR Microwave,photoelectric,and D8224 Mullion Reader heat,and smoke. Enclosures D8103 Universal Enclosure D8224-SP Switch Plate Reader D8 108A Attack-Resistant Enclosure 08225 Mini Mullion Reader D8109 Fire Enclosure 08227 Insert Card Reader MagreticContacts All Bosch magnetic contacts,including recessed,termi- D8301/W Series Low-profile Proximity Readers nal connection,miniature,overhead door,and surface 08302 Vandal-resistant Reader mount. D8303/W Series Mullion Proximity Readers Bells 0440 Bell 12 V,15 cm(6 in.) D8304/W Series Extended Range Proximity Readers D441 Bell 24 V,15 cm(6 in.) WP644 Series Waterproof Pass-through Readers MB-G10-12-R Bell 12 V,25.4 cm(10 in.) Keypads D1260 Series Keypads(D1260,D1260W,D1260R, Technical Specifications D1260BLK,D1260B) SAFECOM Radm SC2104 Series Slave Communicators Communications Communicators SDI Bus A(+): 9 VDC SC3100 Series Data Transfer Radio Communicators 4572 m(15,000 ft) SC4000 Series Full Data Transfer Radio Communicator SDI Bus B(-): 9 VDC Wireless Products D81251NV Wireless Interface 4572 m(15,000 ft) FA1 13 Keychain Remote Control Telephone Connection: • Two TelCo lines FA1 16 Executive Programmer • D928 Dual Phone Line module FA202 Wireless Smoke Detector and Transmitter required for 2 phone lines FA203S Necklace Pendant Transmitter(Single-button) Environmental Considerations FA203DNecklacePendantTransmitter(Double-button) Relative Humidity: 5%to 85%at+30°C(+86°F),non-con- FA204 Necklace Pendant Transmitter densing FA205S Belt Clip/Loop Transmitter(Single-button) Temperature(Operating): 0°C to+50°C(+32°F to+122°F) FA205D Belt Clip/Loop Transmitter(Double-button) Number of... FA206DS PIR Transmitter FA206i PIR Transmitter Areas: 8 FA209 Billtrap Transmitter Card Readers(Doors): 2 FA2 10 Universal Transmitter(Off-white) Credentials(Tokens): 396 FA2 10-BN Universal Transmitter(Brown) Custom Functions: 4 FA2 10W Universal Wide Gap Transmitter(Off-white) Events: Store up to 1,000 FA2 10W-BN Universal Wide Gap Transmitter(Brown) Hardware Addresses: 75 FA2 16L Low Temperature Transmitter Parallel Printers: 1 FA2 16H High Temperature Transmitter Passcode Users: 99,plus 1 service passcode FA223S Water-resistant Pendant(White Single-button) Points: 75(8 on-board,up to 67 off-board) FA223D Water-resistant Pendant(Black Double-but- Programmable Relay Outputs: 67 ton) RF Points: B7 FA250 High-power Universal Transmitter SKEDs: 40 FA400 Remote Receiver Power Requirements FA404R Transmitter Receiver FA416R Transmitter Receiver Current Draw(Minimum): 200 mA FA570 High Power Indoor Repeater Current Draw(Maximum): 500 mA FA575 High Power Indoor/Outdoor Repeater Output(Alarm): 2 A at 12 VDC Output(Auxiliary,Continuous Pow- 1.4 A at 10.2 VDC to 13.9 VDC Parts Included er,and Switched Auxiliary com- bined): D7412G Components Voltage(Operating): 12 VDC Quantity D7412G Board 1 Voltage(AC): 16.5 VAC 40 VA plug-in transformer (D1640) Mounting Skirt 1 Voltage(DC): • Up to 212 VDC,7Ah sealed lead Faceplate with D7412G Label 1 acid rechargeable batteries • Up to 212 VDC,18 Ah sealed lead acid rechargeable batteries D7412G Kit Ordering Information L� ���DT4l2G A p74126 8 D7412G-C D741]G p 74123 Board 1 1 1 —� I E4D—ransto-mer 1 t 1 1 H IJ FrrlosurP wdh t7!O,1 nck anA KPy Set ! I 8?C•8A Attack-Resistant irclns-11e w th❑:U1 1 R1:T0 r el sire with 1C:1r t j-_ock and KH�58—I -- 7:6 1�,?Frclosure with 01011 ck and Key Set [.�12] udl BdCC@f'Harness 1 J92FI Dual FhPna Lire SwrtCtYe! ---- l �-- 1 — ::ii 2.:it 171:1 0 aI Mo L ar c1roge Ooris --?——' --'— Ordering Information Ordering Information D7412G Control Panel D7412G D168A Telephone Remote Arming Module 0168A Includes one printed circuit board(PCB). A remote control module that arms or dis- D7412G Attack-Resistant Kit D7412G-A arms a security system remotely or locally Includes one PCB,one D8108A Attack-Re- through a telephone. sistant Enclosure,and one D1640 Trans- D928 Dual Phone Line Switcher D928 former. Allows the control panel to operate over and D7412G Ire and Burglar Kit D7412G-B supervise two separate phone lines.Only Includes one PCB,one 08109 Fie Endo- one 0162 phone cord is supplied.Two ad- sure,one 0928 Dual Phone Line Switcher, ditional 0161 or 0162 phone cords are and two D161 Dual Modular Phone Cords. required. D7412G Commercial Burglar Kit D7412G-C D1218 Battery(12 V,18 Ah) D1218 Includes one PCB,one 08103 Enclosure, A 12 V sealed lead-acid battery for standby and one D1640 Transformer, and auxiliary power with two bolt-fastened D7412G Commercial Burglar terminals.Includes hardware for attaching Kit 07412G-0 battery leads or spade connectors Includes one PCB,one 06103 Enclosure, and one D 1640 Transformer. 01224 Battery(12 V,24 Ah) D1224 Accessories A 12 V sealed lead-acid battery for standby and auxiliary power with two bolt-fastened ICP-EZTS Dual Tamper Switch ICP-EZTS terminals.Includes hardware for attaching Combination tamper switch with a wire loop battery leads or spade connectors. for additional tamper outputs. D1238 Battery(12 V,38 Ah) 01238 D101 Lock and Key Set D101 A 12 V sealed lead-acid battery for standby Standard lock set with one key supplied, and auxiliary power with two bolt-fastened Uses the 0102(1358)replacement key. terminals.Includes hardware for attaching D122 Dual Battery Harness D122 battery leads or spade connectors. Harness with circuit breaker.Connects two 01640 Transformer 01640 batteries to a compatible control panel. System transformer rated at 16.5 VAC, D122L Dual Battery Harness with Long Leads D122L 40 VA. Color-coded harness with circuit breaker 08103 Enclosure 08103 and leads measuring 89 cm(35 in.).Con- Grey steel enclosure measuring 41 cm x nects 12 V batteries to compatible control 41 cm x 9 cm(16 in.x 16 in.x 3.5 in.). panels. D8108A Attack Resistant Enclosure D8108A D126 Standby Battery(12 V,7 Ah) D126 Grey steel enclosure measuring 41 cm x Sealed lead-acid standby and auxiliary re- 41 cm x 9 cm(16 in.x 16 in.x 3.5 in.).UL chargeable power supply. Listed.Includes lock and key set.Requires D137 Mounting Bracket 0137 the D2402 Mounting Plate. Used to mount accessory modules in 08109 Fire Enclosure D8109 D8103,D8108A,and D8109 enclosures. Red steel enclosure measuring 40.6 cm x 0138 Mounting Bracket,Right Angle D138 40.6 cm x 8.9 cm(16 in.x 16 in.x 3.5 in). Used to mount accessory modules in UL Listed.Includes a lock and key set. 08103,D8108A,and 08109 enclosures. D9002-5 Mounting Skirt D9002-5 Mounts inside D8103,D8108A,and D8109 enclosures.Can accept up to six standard 7.62 cm x 12.7 cm(3 in.x 5 in.)cards. Ordering Information D136 Plug-In Relay D136 Maximum rating is 1 A at 24 VDC or 2 A at 12 VDC.Available individually(D136)or in a package of 25(D136-25). Software Options RPS Kit(LPT) D55000-LPT Account management and control panel- programming software with LPTconnection. RPS Kit(USB) D55000-USB Account management and control panel- programming software with USB connec- tion. Europe,Middle East,Artie: America AsirPadRc. Represented by Bosch Security Systems B.V. Bosch Security Systems,Inc. Bosch Security Systems Pte Ltd P.O.Box 80002 130 Perinton Parkway 38C Jalan Pemimpin 5600 JB Eindhoven,The Netherlands Fairport,New York,14450,USA Singapore 577180 Phone:a 3140 2577 284 Phone:*1 800 289 0096 Phone:*65 6319 3450 Fax:*31 40 2577 330 Fax:+1589 223 9180 Fax:*65 6319 3499 emea.securitysystems@bosch.com security.sales@us.bosch.com apr.securitysystems@bosch.com www.boschsecurity.com www.boschsecurity.us www.boschsecurity.com O BOSCH Invented for life D1256RB Fire VFD Keypad ► Compatible with Bosch GV2 Series control panels (firmware version 7.04 and higher) ► Provides system control with easy to use function keys I ��� ► Built-in multi-tone sounder "� ► Easy to read vacuum-fluorescent display(VFD)shows complete system status in English , ...■ ► Programmable custom text for each point ► Local system test display ► Molded red ABS plastic construction The D1256RB Fire Keypad is a full-function system Certifications and Approvals controller and annunciator.This SDI bus compatible device works with the Bosch GV2 Series control panels (firmware Region Certification version 7.04 and higher). Four one-touch function keys provide user-friendly control over the system.The function USA FM keys allow the user to silence the audible alarm output, Listings and Ap- UL AMCX:Central Station Alarm Units(UL1610) silence the trouble sounder, reset the annunciator display, provals: and reset the system detectors. Four additional ULAPAW:Police Station Alarm Units(UL365) navigational keys allow access to other programmed system ULAPOU:Proprietary Alarm Units(UL1076) functions. The D1256RB can be mounted in secure areas. ULNBSX:Household BurglaryAlarm System Units (UL1023) UL UOXX:Control Unit Accessories,System(UL864 Functions 9th edition) Display UL UTOU:Control Units and Accessories-Household The display uses words,numbers,and symbols to show the System Type(UL985) status of the fire system. When several events occur, each event is shown in order of priority followed by the time of occurrence. In conjunction with the 16-character vacuum- Installation/Configuration Notes fluorescent display (VFD),four LEDs provide the following Compatible Control Panels system status indications: The D1256RB Fire Keypad is compatible with the • Fire D9412GV2,D7412GV2,and D7212GV2*control panels • Silenced with firmware version 7.04 or higher. • Supervisory • Trouble *The D7212GV2 is not listed for commercial fire applications. Mounting Considerations Trademarks The keypad is a low profile, surface-mounted unit molded in durable red plastic with three mounting holes in the base P0LYLAC°isaregisteredtrademarkofCHIME[IndustrialCorporation,LTD. that allow secure, correct Positioning during installation. Plexiglas is a registered trademark of Arkema. Protect the surface-mounted keypad by mounting it to a D56 or D56R Conduit Back Box. For desktop applications, the keypad can be mounted to a D55 Desk Stand. Ordering Information Note Do not install the keypad in direct sunlight. D1256R8 Fire VFD Keypad D1256RB This damages the module components and Accessories makes the display less visible.Do not mount in D55 Keypad Desk Stand D55 wet or moist locations. Portable desk stand in smoke colored Wiring Considerations Plexiglas®. The keypad connects to the control panel for data and D56 Surface Mount Conduit Box D56 power through a standard four-wire flying lead cable. For White surface mount box. field wiring use 0.8 mm(22 AWG)or 1.2 mm(18 AWG)wire. D56R Red Surface Mount Conduit Box D56R Resistance cannot exceed 25 O. The field wiring connects Red surface mount box. to a four-wire harness supplied with the unit. Note Use shielded cable where excessive electromagnetic interference is a problem. Parts Included Quant. Component 1 Keypad 1 Hardware pack 1 Literature pack Technical Specifications Environmental Considerations Relative Humidity: 5%to 85%non-condensing at+30°C(+86°F) Temperature(operating): 0°C to+50°C(+32°F to+122°F) Mechanical Properties Color: Red Dimensions: 11.7 cm x 21 cm x 2cm (4.6 in.x 8.2 in.x 0.8 in.) Material: CHI MEI P0LYLAC°PA757 ABS with UV Stabilizer.UL94-HB Fire Rated Power Requirements Current: 104 mA minimum,225 mA maximum Voltage: 12 VDC nominal supplied by the control panel Amarkas, Europe,Middle East,Africa: Asia-Pacific Bosch Security Systems,Inc. Bosch Security Systems B.V. Bosch Security Systems Pte Ltd RePresanted by 130 Perinton Parkway P.O.Box 80002 38C Jalan Pemimpin Fairport,New York,14450,USA 5600 JB Eindhoven,The Netherlands Singapore 577180 Phone:+1 800 289 0096 Phone:+3140 2577 284 Phone:+65 6319 3450 Fax:+1 585 223 9180 Fax:+31 40 2577 330 Fax:+65 6319 3499 securitysalesous.bosch.com emea.securitysystems8bosch.com apr.securitysystems@bosch orn wwwboschsecurity.us www.boschsecurity.com www.boschsecurity.com D7038 Remote NAC Power Supply Specifications Features • Remote NAC Power Supply with 6 A of notification power • Outputs can be configured for NAC output or constant auxiliary power • 4 Class B,Style Y Circuits • Multiple output patterns • Ground fault indication • Regulated 24 Volt output (nominal) • Over current protection • Charger control monitor • Supervision of AC, battery and circuit expander • Fully supervised outputs • Compatible with the following Radionics controls: D7022 FACP, 07024 Fire Alarm Control/Communicator and the D8024, D9024 and 010024 Analog FACPs Description The Radionics D7038 Remote Notification Appliance Circuit D7038 Remote NAC Power Su (RNAC) Power Supply is UL Listed to be used in commercial fire alarm applications. This regulated power supply provides Application up to six amps of power that are used to recharge batteries and operate both continuous and intermittent alarm loads.This The D7038 is designed to add four additional notification six amps of power can be distributed through the four Class B, appliance circuits (NFPA 72, Class B, Style Y)to a fire alarm Style Y circuits that are part of the D7038.It is also compatible control panel. with any UL Listed control unit utilizing reverse polarity The 07038 can be used with other fire alarm control panels. supervised notification outputs using 24 VDC regulated outputs. Supervision and control is provided through a supervised, The D7038 is provided in a red enclosure that houses the polarity reversal output(depending on the panel that is in use). power supply board and standby batteries. Ample room is For the D8024, 09024 and D10024 analog panels,the D7038 provided inside the enclosure to make AC power connections connects through a NAC circuit. No serial bus connection is and route field wiring to connection points on the power supply necessary. board. All wiring is connected to the power supply board via The D7038 can also be used as a power supply for fire- sa-ew terminals that can accept up to#12 AWG(2.3 mm)wire. protective signaling systems. The D7038 can be connected to the 07024 via the four wire Installation connection to the Option Bus. This connection provides individual control of each output by the D7024, and complete The D7038 power supply board and enclosure are shipped in supervision of the power supply. one box. The D7038's enclosure should be mounted in a The following options can be set with the DIP switches:Option convenient location for servicing and maintenance.The power Bus Address, NAC Input Variable and AC Failure Time Delay. supply board must be mounted in the enclosure using the The NAC Input Variable option allows for split functioning of provided hardware. the D7038's inputs. Input 1 can either be set to drive all four Primary power(120 VAC)from an unswitched dedicated branch NAC outputs, or NAC Outputs 1 and 2. If the latter option is circuit is routed to the power supply enclosure and connections chosen, then Input 2 will drive NAC Outputs 3 and 4. are made inside. Field wiring to control modules or There are seven local status display LEDs on the D7038 board continuously powered devices are routed into the enclosure that monitor the following conditions: High Voltage, AC OK, via knockouts provided on the enclosure. Low Battery, Loop Trouble, Ground Fault, Output Active and When all circuits are determined to be free of earth grounds NAC Short. and wire-to-wire shorts,connect the primary power to the supply and then install the batteries in the locations provided in the enclosure. A member of the radionics Bosch Group Specifications Operating Temperature +32°F to+120°F(0°C to+49°C) Output Voltage 24.1 or 27.4 VDC Input Power 120 VAC,60 Hz,2.5 A Max.Output Current 850 mA Battery Voltage 24 VDC,nominal(20.2 to 28.0 VDC) Max.Battery Capadty 38 Ah Output Voltage(AC Operation) 27.4+1-0.1 VDC @25°C(77°F) Cord Type Form-C• Contact Rating 1.5 A©32 VDC Output Voltage(DC Operation 24.1+1-0.6 VDC Q 25°C(77°F) Total Our Curry 6A Listings and Approvals Ripple voltage ≤250 mV • UL 864 Listed Control Unit Accessory Enclosure Dimensions(w/o door) 14.8 in.W x 20.4 in.H x 4.1 in.D • UL1481 Listed Power Supply for Fire-Protective Signaling (38cmWx52tmHx10.4anD) g Systems • CSFM NYC-MEA Input votiage fl VDCIVRMS Ordering Information Input to Output Response Time ≤50 me EOL Resistor User suppled D126 12 V,7 Ah Battery D1224 12 V,24 Ah Battery Standby Voltage -5.0 VDC EOL Resistor 2.2K ohms+1.5% D1238 12 V,38 Ah Battery Output Voltage 24.1 or 27.4 VDC) D7038 Remote NAC Power Supply Rated Output Current(per ougwt)x 4 1.5 A Max.Output per Circuit 2.5 A Max.Output for Al Circuits 6.0 A Local Status Display LEDs High Voltage LED Dipswtich Bank O AC POweLJj O Option Bus TerminalsI ? , Terminals •11 VOLTAGE 1/O r Terminals � 't rrxO Battery Red Leads D7038 Remote NAC Power Supply Board tso 9002 U� CERTIFICATE Na A5137 ©2001 Radionics,a division of Detection Systems,Inc. PM:38788D 8101 PO Box 80012,Salinas,CA 93912-0012 USA Specifications D7038 Customer Service:(800)538-5807 L960 Page 2 of 2 ■ Features Single or Dual Action • Key Reset DSMS-SAWK Single Action,Leads,Key • Wire Leads or Terminal Connectors DSMS-SATK Single Action,Tertninafs,Key • Gold Plated SPST Contacts DSMS-DAWK Dual Action,Leads,Key • Mounts on Standard Single Gang Box DSMS-GR Dual Action Tent*aais,Key • Surface and Weather-proof Backboxes Available Hose: AN gels are shipped with one scored acrylic breakrod and • High Gloss Red Enamel Finish one key • Scored Acrylic Breakrod • ADA Compliant • UL Listed, CSFM Approved ■ Basic Function Operation PUSH • The DSMS Series is operated by pulling the handle on the front of the station as far down as it will go, at PULL PULL which point the handle locks into place and is easily visible from up to 50 ft. (15 m). The handle is reset by opening the station with the key, placing the handle in the normal upright position and re-locking the station. On the action models, the push bar rotates inward allowing the Pull handle to be grasped in a one handed motion. ■ Certifications THe DSMS is a high quality, die-cast metal Fire Alarm UL Listing$6650 CSFM 7150-1062:124 Pull Station available in either single or dual action configurations with SPST gold contacts, key resets, and either wire lead or terminal strip connections. The normally open contact, which closes when the pull station is activated, is rated for 1 amp, 30 VDC. The contacts are gold plated to avoid the risk of corrosion. All models in the series have been tested by UL for compliance to the latest requirements of the Americans with Disabilities Act(ADA). r7C■ iintoriinn eic}cme A ,o,,.f fhn ■ Wiring ■ Optional Accessories C d' '^z ,G wt+" vy,'hSa£d d uu fi F W f sx. sa • J rw;;r xan ww„p:aa+" x+mc��ss wA,�s Mweur. r+ J € a Ed Qa wa ILL FU > c 005 O W H w J m' M J a U ¢a do L C HU ■ Technical Specifications All models mount on a standard single gang backbox, model DSMS-BB interior surface metal backbox, or DSMS-WBB weather proof backbox 1 Amp Q 30 VDC or 120 VAC 4.75in.Hx3.25in.Wx1.1i.D (12 cmHx8.3cmWx2.8cmD) war s;� 4.75n.Hx3.25in.WxP-25in.D (12 cmHx8.3cmWx5.7cmD) Body:Red with raised white letters. Pull Bar.White with red raised letters. P/N 45791 D Detection Systems,Inc. 1'An Porintnn Parkway Faimnrt Now Vnrk 16dcr1-QjQQ 's°'°°'n 1 1 Fire I F220 Photoelectric Smoke Detectors F220 Photoelectric Smoke Detectors The F220 photoelectric smoke detectors are UL Listed,open-area photoelectric smoke detectors designed for use with commercial fire protective signaling systems and household fire warning systems(see NFPA 72,the National Fire II I/ Alarm Code).These smoke detectors scatter light using a pulsed infrared _ source operating with a gated, high-speed,photodiode infrared sensor. The symmetry of the optical chamber allows 360°uniform smoke entry,but minimizes external light entry.By using low current electronic circuitry,you can connect the detectors to a wide range of power source circuits. Features Monitoring the Detection Chamber • Two- or four-wire bases These detectors have several features that work together to • Use with 12 VDC or 24 VDC systems maximize the performance of the optical chamber: • Optional CO-sensor,heat-sensor enhanced detection Compensation:The detector monitors the chamber for chamber the effects of dust build-up within the chamber and • Clean chamber without removal or disassembly automatically compensates for these effects.If the • CleanMe®signaling capability chamber becomes contaminated beyond compensation, • Sensitivity readout on detector the green LED flashes every 4 sec to indicate trouble. • Detector chamber compensates for dust build-up Chamber Check®Self-diagnostics:The detector • Tamper protection automatically indicates visually if the calibration is out • Dual-color LED of the factory-listed range.This meets NFPA guidelines for sensitivity testing,because you can visually inspect Basic Functions the detector and check the flash rate of the LED.If the Compatible Bases calibration is out of range,the green LED on the detector Configure the detectors into two-wire or four-wire versions by flashes once every 4 sec.This indicates that the detector selecting the appropriate mounting base.These detectors are must be cleaned per the instructions provided with the compatible with any of the F220-B6 bases: detector. • F220-B6 Two-Wire Mounting Base CleanMe Mode:Indicates if the calibration is out of the • F220-B6R Standard Four-Wire Mounting Base factory-listed range by sending a trouble signal to the • F220-B6C Four-Wire Mounting Base with Auxiliary CleanMe-compatible control panel,if so programmed. Relay • F220-B6E Power Supervision Mounting Base ROSE14 2 1 F220 Photoelectric Smoke Detectors • Chamber Maid'"':The detector has a unique,patent- Tamper Detection pending cleaning mechanism.Use the valve on the back When detector heads are properly installed in any of the F220- of the detector to insert the nozzle of a can of clean,dry B6 bases,tamper detection is provided by the wiring of the compressed air.Clean the chamber with a short(1 to 2 positive power line.The control panel initiates a trouble signal sec)blast of air. if a detector is removed from its base.A mechanical tamper Heat and Carbon Monoxide Enhancements lock comes with each base to prevent unauthorized head The detectors are available with an optional fixed-temperature removal heat sensor or a combination of heat and CO sensors.These optional sensors enhance the operation of the smoke detector Certifications and is by reducing false alarms. • Carbon Monoxide:Without the presence of CO,a Listings and UROX:Smoke-Automatic Fire Detectors norm byproduct of combustion,the detection Approvals: (UL268) al chamber is half as sensitive to smoke as a standard ULGS52ao2 commercial photoelectric smoke chamber.This reduces Planning false alarms.When the sensor detects CO,the detection chamber's sensitivity to smoke increases so it equals or Compatible Control Panels exceeds that of a standard commercial photoelectric Two-wire:Refer to Technical Service Note(P/N: smoke chamber. 4998148185). • Heat:When the heat sensor detects a temperature rise, Note: Bosch Security Systems makes no claim written, the photoelectric chamber becomes more smoke oral,or implied that the F220 Photoelectric Smoke sensitive.The heat sensor initiates an alarm if the Detectors work with any two-wire control panels ambient temperature exceeds+135°F(+57°C). except those specified in the Control Panel Dual-color LED Compatibility chart in the Technical Service Note A dual color LED indicator flashes green every 8 sec when the F (P/N:4998148185). detector has power and the smoke sampling circuitry is our-wire:Compatible with all UL Listed four-wire working.If CleanMe is enabled,the green LED double flashes control panels.Refer to the manufacturer's installation instructions for proper EOL resistor selection. (two flashes a half second apart)every 8 sec to indicate normal operation.The LED turns red if an alarm is sent.After the Mounting the Bases alarm condition clears,reset the detector by interrupting its Note. Consult NFPA 72 for proper detector placement. power.If the chamber becomes contaminated beyond Depending on local regulations,the bases can be surface compensation,the green LED flashes every 4 sec to indicate mounted directly to four-inch square or octagonal electrical trouble. boxes and single-gang switch boxes. Test Functions Warning: The volume of any electrical box used should be The F220 Photoelectric Smoke Detectors feature a unique large enough to accommodate the number and size magnet operation and sensitivity test function.Test the ofconductors as specified by the National Electrical by placing the Code or any local Authorities Having Jurisdiction detector's operation magnet next to the (AHJ). detector's LED for three consecutive flashes.This causes the detector to send an alarm.Placing a magnet next to the Loop Supervision detector's LED for at least one red flash but less than three Loop supervision requires one EOL200 or F220-B6E per loop flashes activates the detector's sensitivity mode. when using F220-B6R/B6C/B6RC bases and is supervised by the control panel. Wiring the Bases Note: Refer to the F220 Series Installation Instructions (P/N:4998138694)for detailed instructions. Screw Terminal Connections:Do not twist the wires or loop the wires around terminals.The wires for terminal connection must be cut,stripped,and inserted as individual ends. F220 Photoelectric Smoke Detectors 13 Order Number F220-B6 usx.8µa+ fvk w �`me Use the F220-B6 Mounting Base with two- Photoelectric detector head with heat and CO sensors only; wire(12 VDC or 24 VDC system) requires base. applications.It is UL Listed when used in Note: The CO sensor is not a separate detector.It combination with the UL Listed,F220 enhances the operation of the smoke detector. detectors. Technical Specifications Photoelectric detector head only;requires base. Power Requirements Current(alarm): limited to 20 mA minimum at 8.5 VDC; 35 mA maximum at 32 VDC. aY Current(standby): nominally 90 pA at 12 VDC,100 pA at Photoelectric detector head with heat sensor only r u eqires 24 VDC,and 120 pA maximum at 32 VDC base. Hardware Accessories Order Number F22O-B6R The F220-B6R Mounting Base is the Order Number DRA-5 standard base for four-wire(12 VDC or 24 VDC)detector systems.It is UL Listed Provides remote annunciation of alarms when used in combination with the UL for fire detectors.Voltage is 5 VDC. Listed F220 detectors. Current draw is 10 mA at 5 VDC. Dimensions(H x W x D)are 4.8 in.x 3.1 in.x 0.25 in.(12.3 cm x 7.8 cm x Technical Specifications 0.63 cm). Outputs Alarm relay type: normally open(NO)and closes on alarm Order Number DT-2 Relay rating: 0.5 A at 100 VDC Power Requirements Current(alarm): 13.5 mA at 12 VDC,16.5 mA at 24 VDC,and Use the DT-2 to remove,replace,or test the detector head by attaching the appropriate 19 mA maximum at 30 VDC Current(standby): nominally 90 pA at 12 VDC,100 pA at length of half inch diameter conduit(not 24 VDC,and 120 pA maximum at 32 VDC supplied).Test magnet supplied. NumberOrder EO ��, Order Number F22O-B6C Used with four-wire 12 VDC or 24 VDC systems for power supervision.Uses a The F220-B6C Mounting Base has a 2.2 W EOL resistor. normally-open(NO)alarm loop relay and a set of auxiliary contacts.It is UL Listed when used in combination with the UL Listed F220 detectors. 4 1 F220 Photoelectric Smoke Detectors Technical Spec{fications Technical Sp ecifications Outputs Auxiliary contacts: One set of norm Detector/Base Design ak-open(NO),common(C), Color: White normally dosed(NC)contacts Dimensions(diameterxD): 6.75 in.x 2.25 in. Contact rating: 0.5 A at 125 VAC, 1.0 A at 30 VDC for resistive loads 07.1 cm x 6.4 cm) Environmental Considerations Power Requirements Relative Humidity: 0%to 95%noncondensing Current(alarm): 31 mA at 12 VDC,35 mA at 24 VDC,and (15%to 95%noncondensing for CO 40 mA maximum at 30 VDC Current(stand sensing models) by): nominally 90 pA at 12 VDC,100 NA at Temperature +32°F to+100°F(0°C to+38°C) 24 VDC,and 120 pA maximum at 32 VDC (normal operation): Power Requirements Current(alarm): 20 mA minimum at 8.5 VDC; Order Number F220-36E x5 (dd only) 35 mA maximum at 32 VDC Current(start-up): 0.12 mA maximum at 32 VDC Maximum The F220-B6E Power Supervision Base has RMS Ripple: 25%of DC input Power-up Time: 22 seconds maximum a normally open(NO)alarm relay and an Voltage(standby): Two-wire:8.5 VDC to 32.0 VDC EOL power supervision relay.The EOL Four-wire:10.0 VDC to 30.0 VDC relay eliminates the need for separate Trademarks power supervision devices.It is UL Listed ® Chamber Check®is a registered trademark of Bosch Security when used in combination with the UL Listed F220 detectors. Systems in the United States. Chamber Maid"''is a trademark of Bosch Security Systems in Note: Use only one F220-B6E base per the United States. zone run as the last base on the CleanMe is a trademark of GE Interlogix. run in a style B circuit. Technical Specifications Outputs Alarm relay type: normally open(NO),closes on alarm Relay rating: 0.5 A at 100 VDC for resistive loads Power Requirements Current(alarm): 25 mA at 12 VDC,30 mA at 24 VDC,and 34 mA maximum at 30 VDC Current(standby): 16 mA maximum at 30 VDC Bostsh Secrrity Systems BOSCHFor more inionnation please visit ltYsyWWosdiaectem&com deal for 2 wire applications with 3 se actable dBA settings (99, 95, 99)and Wall Mount Horn Strobes vall or ceiling mounting. F R; Available features and options: E. Color: Red or White Mounting: Wall or Ceiling AS-24MCW-FR Red Order co 9024 de UL Max.Current 15cd 30cd 75cd 11 Multi-Candela or High Intensity 0cd AS-24MCW-FW White 9025 High(99)dBA 24 VDC 0.088 0.125 0.200 0.267 135/185cd Med(95)dBA 24 VDC 0.074 0.110 0.190 0.253 Square AS-24MCWH-FR Red 3468 Low(90)dBA 24 VDC 0.068 0.105 0.182 0.245 Standard Backbo-eS AS-24MCWH-FW White 3469 1575cd UL Max.Current 135cd 185cd 1575cd Strobe/horn Synchronization AS-241575W-FR Red 7405 24 VDC 12 VDC AS-241575W-FW White 7420 High(99)dBA 0.355 0.480 0.121 0.320 Approvals: UL, ULC, FM, 1575cd Med(95)dBA 0.340 0.465 0.107 0.275_CSFM, MEA, BFP AS-121575W-FR Red 7410 Low(90)dBA 0.335 0.460 0.100 0.265 AS-121575W-FW White 7425 Mounting Options: B,D,E,F,G,H,J,N,O,PR,X Ceiling Mount Horn Strobes ieries AS 480 FIRE UL Max.Current 15cd 30cd 75cd 95cd High(99)dBA 24 VDC 0.095 0.138 0.221 0.285 Med(95)dBA 24 VDC 0.080 0.121 0.201 0.269 4 8o == Low(90)dBA 24 VDC 0.074 0.113 0.198 0 263 15/30/75/95cd Order Code AS-24MCC-FR Red 3161 UL Max.Current 115cd 177cd o AS-24MCC-FW White 3162 High(99)dBA 24 VDC 0.355 0.480 115/177cd Med(95)dBA 24 VDC 0.340 0.465 AS-24MCCH-FR Red 3466 Low(90)dBA 24 VDC 0.335 0.460 ieries AH AS-24MCCH-FR White 3467 Mounting Options: B,D,E,F,G,H,J,N,O,PR,X 4.8 Wall or Ceiling Mount Horns - 1 . Order Code UL Max. Current AH-24-R Audible AH-24-W Red 7892 24 VDC 12 VDC White 7893 High(99)dBA 0.080 0.192 AH-12-R Red 7891 Med(95)dBA 0.043 0.108 AH-12-W White 7894 Please reference the back of this catalog for Low(90)dBA 0.021 0.058 more information on mounting options. For the Series ASWP or AHWP Weatherproof Mounting Options: B,D,E,F,G,H,J,N,O,PR,X appliances,please see page 1-11. 1-2 06/06 (800)631-2148 • www.cooperwheelock.com Wall Mount Strobes/Strobe Plates RSS Strobes provide a wide range of intensities and mounting options for wall or ceiling applications. RSSP Strobe Plates are designed for retrofitting existing audible notification tI appliances to strobe applications FIRE Available features and options: Color: Red or White Mounting: Wall or Ceiling 15130i75/110cd Order Code RSS-24MCW-FR Red 9400 UL Max.Current 15cd 30cd 75cd 110cd Multi-Candela or High Intensity RSS-24MCW-FW White 9401 24 VDC 0.060 0.092 0.165 0 220 Retrofit Plates 135i185cd Round or Square RSS-24MCWH-FR Red 3465 UL Max.Current 135cd 185cd RSS-24MCWH-FW White 3464 24 VDC 0.300 0.420 Replaceable Cover 1575cd Standard Backboxes RSS-241575W-FR Red 7471 UL Max.Current 15/75cd RSS-241575W-FW White 7788 24VDC 12VDC Strobe Synchronization 1575cd 0.090 0.255 Approvals: UL, ULC, FM, CSFM, RSS-121575W-FR Red 7476 MEA, BFP RSS-121575W-FW White 7468 Mounting Options: B,D,E,FG,H,J,N,O,PR,X Strobe Plates Order Code D,E,Z(Strobe Plates) 15/30/75/110cd RSSP-24MCW-FR Red 9402 RSSP-24MCW-FW White 9403 135/185cci 2.58_n Series RSS Round RSSP-24MCWH-FR Red 9482 4.75 2.58_ 1575cd RSSP-241575W-FR Red 7493 .82� RSSP-241575W-FW White 7992 7.38 1575cd RSSP-121575W-FR Red 7798 RSSP-121575W-FW White 8109 Ceiling Mount Strobes F n Series RSSP �s.86 2.70 .56r Round Order Code 15/30/75/95cd o 0 RSS-24MCCR-FR Red 3159 11.76 RSS-24MCCR-FW White 3160 UL Max.Current 15cd 30cd 75cd 95cd 115/177cd 24 VDC 0.065 0.105 0.189 0.249 FIR E RSS-24MCCHR-FR Red 3462 �(� RSS-24MCCHR-FW White 3463 UL Max.Current 115cd 177cd II Il�� Square Order Code 24 VDC 0.300 0.420 FIR E 15/30/75/95cd RSS-24MCC-FR Red 3157 RSS-24MCC-FW White 3158 115/177cd Please reference the back of this catalog for more information on mounting options. RSS-24MCCH-FR Red 3460 Mounting Options: B,D,E,F,G,H,J,N,O,P,R,X RSS-24MCCH-FW White 3461 For the Series RSSWP Weatherproof appli- ances,please see page 1-11. (800)631-2148 www.cooperwheelock.com 1-7 06/06 • DTK=MRJ Series Modular Station Set SURGE PROTECTION thii 111111 DTK-MRJ-11 DTK-MRJ-14 ,yx222 } �i tea" D DTK-MRJ-25 TK-MRJ-45 ti "Location, location, location!" "Who cares?" With the "MRJ" series of surge protectors from DITEK, you can protect two line systems and individual equipment at the service entrance, the "Point of Use" equipment, or anywhere in between. Plus, with over one hundred variations of components, wiring and pin configurations, there are not many applications that can't be protected. From incoming "CO" lines, to stations, TI, ISDN, RS data and more, DITEK's "MRJ" series will protect them all. FEATURES I BENEFITS Multiple damping voltages Meets specific applications Modular Easy integration =self--resetting e protection Voltag e&erage in9 (specifyprotection .-- - Self Restoring Lower maintenance ONE DITEK CENTER 1720 Starkey Road, 1-8753-2345 Largo,FL 33771 www.ditekcorp.com �TEK General Specifications - MRJ Series Agency Approvals: UL497B, UL497A(specify) Connection Method: Universal RJ11/14/25/45(1-4 pair, specify) Continuous Current: 0.150 Amps ('SCP') 5.0 Amps (non 'SCP') Protection Modes: T-G, R-G(all modes) Warranty: Limited Lifetime Warranty Dimension: 3.08"x 2.67"x 1.16" Weight: 0.44 lbs Housing: ABS Other Specifications D X LV OPX SPK SGR RUV Service Voltage 6V 14V 30V 50V 75V 95V 130V MCOV: 8VDC 18VDC 38VDC 66VDC 102VDC 127VDC 175VDC Typical clamp: 9-16 20-24 42-52 74-90 108-132 135-165 184-224 Max Surge Current: 2000 2000A 2000A 2000A 9000A 9000A 9000A Joules *: 4 8 17 30 44 60 76 *Per pair —y m ` _ 22' I i 'I, � r M198-MRJ Rav4/9M3 _ DTK-1 20S 1 5A Series SURGE PROTECTION The DTK-120S 15A `Critical Load' surge protector from DITEK is a true multi-stage series hybrid design which provides the best filtering and lowest clamp levels in its class. Available in both 120V and 120/240V versions for circuits up to 20 Amps, it meets both government and military specs for fire panel applications. A user replaceable fuse means less down time and longer service life. FEATURES BENEFITS Series Design Fastest response time available; Tighter clamp than parallel device Hybrid Protection Circuitry Four stages of protection insures maximum performance User replaceable fusing Less"post event"downtime Screw Lug Termination Speedy connect/disconnect of power wiring; Neat appearance, no wire nuts needed Low profile design Uses less space, fits wide variety of cabinet depths Multiple diagnostic indicators Monitor protection status, ground presence, ground fault and fuse status ONE DITEK CENTER 1-800-753-2345 1720 Starkey Road, www•ditekeorp.com Largo,FL 33771 General Specifications - 120S15A Agency Approvals: UL 1449,Wyle Labs Service Voltage: 110-120 VAC or 120/240 VAC MCOV: 130 VAC or 130/260 VAC Continuous Current: 15 or 20 S Amps P (Specify) Max. Surge Current: 39,000 Amps EMI/RFI Noise Filtering: >56db 100KHz- 100MHz Protection Modes: L- L, L- N, L -G, N - G Suppressed Voltage Rating: 330V Warranty: Limited Lifetime Warranty Diminsions: 6.00"x 3.58"x 2.32" Weight: .55 lbs. Housing: ABS 27C0W 294' ® :_ J(161 61* 1X.J1' r 11 23 I II 2X2.2 M-198/S 15A Rev 3/23/03 L _