HomeMy WebLinkAbout08-8005 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 8005 FIRE ALARM SYSTEM PERMIT Permit Number: 8005 Address: 4330 20TH ST Permit Type: FIRE ALARM SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: LIGHT INDUSTRY Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 13-26-21-0070-08900-0020 Improv. Cost: 17,881.00 Date Issued: 7/16/2008 Name: NESTLE WATERS NA, INC Total Fees: 150.00 Address: 4330 20TH ST Amount Paid: 150.00 ZEPHYRHILLS, FL. 33542 Date Paid: 7/16/2008 Phone: Work Desc: ADD TO EXISTING FIRE ALARM 10 NEW DEVICES SIMPLEX GRINNELL LP FIRE ALARM 50.00 FIRE PLAN REVIEW FEES 50.00 FIRE INSPECTION FEES 50.00 [bad go /1 & n,O FIRE ACCEPTANCE Final FIRE ELEVATOR RECALL6.1 Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." CONTRACTOR SIGNATURE I IC R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- Fire Marshal Office- 813-780-0041 _ .__ City of zepnyrnnls hermit Appncauon Building Department ' Date Received Phone Contact for Permitting '9 l 3 £I2 _ Owner's Name N� fie/�5 /c i.v �i Owner Phone Number / Owner's Address L v,/ 1,J ry µ- m a N Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS [ ' 7 3 Z b`i $T ?_ PA y 2`,,//S FL 33S P LOT LI 1 SUBDIVISION Z c PGA =/�S C1 PARCEL ID# -Z� l06 70 0 p©oa WORK PROPOSED B (OBTAINED FROM PROPERTY TAX NOTICE) NEW CONSTR ADD/ALT Q SIGN MOVE I t -- INSTALL e REPAIR L_..I DEMOLISH PROPOSED USE 0 SFR COMM TYPE OF CONSTRUCTION [l FRAME D OTHER LIII I] El STEEL [l OTHER[III III] DESCRIPTION OF WORK T p E I ,�.t --..L N ST%4C1 (_,t. A/*izm -j& BUILDING SIZELIjIIIIIIIIIjIjIIIjjIjIIIIJ ii ,11111 • , •i Sq FOOTAGE H .ji,,rr,ri11't,,nr., r, jj •, EIGHT VALUATION OF TOTAL CONSTRUCTION [J ELECTRICAL $J _-] AMP SERVICE EJ PROGRESS ENERGY a El PLUMBING $ . WR.E.C. C� MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION GAS Q ROOFING FINISHED FLOOR ELEVATIONS SPECIALTY Q OTHER FLOOD ZONE AREA AYES []NO BUILDER SIGNATURE TT J - COMPANY 'M (j REGISTERED N FEE CURRENT Address Y/N ff r l t ld `T ,wP4 License# l� C7pC, I f ELECTRICIAN 33(0! SIGNATURE COMPANY EE C REGISTEREDFURRENT Address Y/N License# !� PLUMBERLIIIIIIIIIII 1111111111 SIGNATURE COMPANY REGISTEREDFEE CURRENT Address Y/N MECHANICAL License# SIGNATURE COMPANY Address REGISTERED Y/ N FEE CURRENT Y/N OTHER License# SIGNATURE COMPANY REGISTERED Y/ FEE CURRENT Address Y 7 N RESIDENTIAL License# Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans W/Silt Fence COMMERCIAL Sanitary Facilities& 1 dumpster;Site Work Permit for subdivisions/large projects Attach(3)sets of Building Plans;(1)set of Energy Forms.R-O-W permitor new construction. installed, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fen SIGN PERMIT Sanitary Facilities& 1 dumpster. Site Work Permit for all new projects.All commercial requirements must meet compliance Attach(2)sets of Engineered Plans. Fence Installed, "PROPERTY SURVEY required for all NEW construction p Directions: Fill out application completely. Owner&Contractor sign back of application, notarized "" If over$2500,a Notice of Commencement is required. (A/C upgrades over$5000) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same 'OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter If on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation.Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be Identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with'a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and.Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the Information in this application is accurate and that all work will be,done in compliance with all applicable laws regulating construction, zoning and land development.. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in.the jurisdiction. I also certify that I Understand that the regulations of other government agencies may apply to the Intended work, and that it is my responsibility to Identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US'Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill:- - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. If the fill material is to be used In Flood.Zone "A", it is understood that a drainage plan addressing a • "compensating volume" will be submitted at time of permitting which Is prepared by'a,professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If.fill, material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached-permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to,violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit Issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension maybe requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for.ninety(90)consecutive days, the ob is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT. CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this by by Who Is/are personally known to me or has/have produced Who Is/are personally known to me or has/have produced • as identification. as Identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped SiMPIOXOrinnOll FIRE A business unit of lyco Fire&5 ,r ALARM BE SAFE. SUBMITTAL SUBMITTAL DATE: May 27, 2008 NEW CONSTRUCTION PROJECT Zephyrhills Water 4330 20th Street Zephyrhills Florida, 33542 GENERAL CONTACTOR Haskell Construction Jacksonville, Florida ELECTRICAL CONTRACTOR E F Lea 339 East 50th Street Jacksonville, Florida 32208 ARCHITECT ELECTRICAL ENGINEER FIRE ALARM INSTALLATION / SUPPORT SIMPLEXGRINNELL 4701 OAK FAIR BLVD. TAMPA, FL 33610 PHONE: 813-626-5482 FAX: 813-664-1731 PROJECT MANAGER: :LEE SELLERS SALES REPRESENTATIVE :ALLEN VARGA Simplex6sinneft A business unit of Tyco Fire&Security BE SAFE. NEW CONSTRUCTION PROJECT Zephyrhills Water 4330 20th Street Zephyrhills Florida, 33542 SECTION AMOUNT PRODUCT ID DESCRIPTION COVER FIRE ALARM SUBMITTAL COVER INDEX INDEX WITH BILL OF MATERIALS A SUBMITTAL APPROVALS B INSTALLATION &TECHNICAL SUPPORT C WARRANTY D SCOPE OF WORK E DEVICE MOUNTING HEIGHTS F WIRING DISTANCE GUIDELINES SUBMITTAL APPROVALS ARCHITECT ELECTRICAL ENGINEER GENERAL CONTRACTOR OTHER APPROVAL PLEASE RETURN A COPY OF APPROVED SUBMITTALS TO SIMPLEXGRINNELL FOR EQUIPMENT RELEASE Technical Installer Support (TIS) TIS is'designed to make the expertise of a Simplex technician available at key, scheduled times during the project. This service is available during normal Simplex working hours, if scheduled five working days in advance. TIS includes the following activities by a factory-trained technician,when determined by Simplex to be appropriate. • Pre-construction review of submittals and drawings with the installer. • Technical advice during initial start up of control panels (including transponders) before installer wiring is connected. • Review of panel wiring, and preparation of a list of any items to be corrected by the installer. • Initial programming of control equipment. • Program editing to correct minor errors and omissions. • Assistance with one complete, functional test of the system. • One training session for the owner's representative. Additional installation support may be purchased from Simplex. TIS contributes significantly to the installation of Simplex equipment but does not alleviate the installer's responsibility to: • Provide skilled labor and supervision to complete the project. • Review and understand Simplex instructions for installing and testing Simplex equipment. Potential problems can be avoided by adhering to the following: • Do not initially start up the system, except in the presence of a Simplex technician. Simplex assumes no liability for damaged equipment, and warranty may be voided it this procedure is not followed. • Do not install smoke detectors (unless protected by plastic bags) until final construction clean up has occurred. This prevents damage caused by dust, dirt, and paint. Detectors installed prior to clean up may requite disassemble, cleaning, or replacement which is not covered by warranty. • Care must be taken to protect equipment during the installation and warranty period. Failures due to external causes (lighting surges, construction dust, water damage, etc.)will be repaired by Simplex only upon receipt of a valid written Purchase Order. • TIS includes one complete system test, which is coordinated by the installer. To avoid additional charges, the installer should schedule this test so that all appropriate parties are present. SimplexGrinnell A busrne unit of Tyco Fire&Security E SAFE. THE SimplexGrinnell WARRANTY—HARDWARE SIMPLEXGRINNELL WARANTY STATEMENT: SimplexGrinnell warrants to the purchaser of new SimplexGrinnell building systems product(s)that during the effective period of the warranty such product(s)shall be free of defects in workmanship and material. WARRANTY PERIOD: The warranty period will terminate immediately following the earliest occurrence of either of the following: • 18 months have elapsed following shipment of any system or subsystem from SimplexGrinnell to the customer site,or • 12 months have elapsed following the final connection operation and beneficial use of all or any part of the system. SIMPLEXGRINNELL OBLIGATION UNDER THE TERMS OF THE WARRANTY: SimplexGrinnell sole responsibility shall be to repair, adjust or replace at its option any SimplexGrinnell product which fails during this period, provided purchaser has promptly reported such failure to SimplexGrinnell in writing. Replacement parts provided under warranty of products may contain used parts which are equivalent to new parts when used. Replacement parts will be warranted only for the balance of the equipment warranty. SimplexGrinnell agrees to continue to honor all of the unexpired express warranties specified above on defective equipment after transfer of the equipment to purchaser's customer,provided purchaser's customer assumes the purchaser's obligations specified below. Except for the express warranties stated herein SimplexGrinnell disclaims all warranties on products furnished hereunder, including without limitation, all implied warranties of merchantability and fitness for a particular purpose, and the stated warranties are in lieu of all obligations or liabilities on the part of SimplexGrinnell arising out of or in connection with the performance of the products. The seller shall not be liable for a direct, incidental of consequential loss or damage to the purchaser or user of the equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. SimplexGrinnell make no warranty and now warranty shall be deemed to exist, that purchaser holds the goods free of claim of any third person by way of patent infringement for the like. PURCHASER'S OBLIGATION UNDER THE TERMS OF THE WARRANTY: This warranty is contingent upon the proper installation and use of the product(s). Such warranty shall not apply if the product failure is the result of accident, unusual physical, electrical or electromechanical stress, neglect, misuse, user programming errors, failure of electrical power, air conditioning or humidity control, construction dust, damage foreign substances, transportation or causes other than manufacturing defect. Purchaser agrees to provide full and free access to authorized SimplexGrinnell employees. WARRANTY SERVICE HOURS: Services provided under this warranty will be performed during 8:00 a.m. to 5:00 p.m. Monday through Friday, excluding locally observed SimplexGrinnell holidays. Off-hours response is available as an extra cost service option. WARRANTY EXCLUSIONS: • Labor,travel and mileage for: a. Service outside of SimplexGrinnell normal business hours. b. Programs and/or label changes c. Failures due to external caused(lightning surges,construction dust,etc.)other that manufacturing defect. • Electrical work external to the equipment supplied by SimplexGrinnell or maintenance of accessories, alterations, attachments or other devices not furnished by SimplexGrinnell. • Batteries • Coverage of equipment classed as a water flow monitoring/control devices installed in or on water piping. SimplexGrinnell LP SinpIexGrinneII aid Blvd. Tampa, FL 33610 A business unit of Tyco Fhe&Security Tel: 813-626-5482 Fax: 813-664-1731 BES FE„ www.simplexgrinnell .corn SCOPE OF WORK Provide, program and test 10 duct detectors for MAU and Supply Fans as shown on drawing EL3 & 4. Install a 127 point card in 4020 to increase panel point capacity to handle the new duct detectors. ice- 2 tll�i f r 2 `LS C 0 C� _ S Z uflr< tS s oz m � �1Ca " ri 2 cD Zh ?Z rwc rn 9 ------------- 1n�f 41Y0� yY r'i Jl7 n c-r icy l a 1 om WIRE_DISTANCE GUIDELINES TRUEALERT WIRE DISTANCE Conventional,Strobe Wire Distance Guideline GUIDELINE Wire Max. Wire Max. Wire Max. Wire Max. Amps Gauge Length Gauge Length Amps Gauge Length Gauge Length 0.1 14 6,140 12 9,766 0.1 14 2,500 12 2,500 0.2 14 3,070 12 4,883 0.2 14 1,640 12 2,500 0.3 14 2,047 12 3,255 0.3 14 1,097 12 1,788 0.4 14 1,535 12 2,442 0.4 14 825 12 1,343 0.5 14 1,228 12 1,953 0.5 14 662 12 1,077 0.6 14 1,023 12 1,628 0.6 14 553 12 899 0.7 14 877 12 1,395 0.7 14 476 12 772 0.8 14 767 12 1,221 0.8 14 418 12 677 0.9 14 682 12 1,085 0.9 14 372 12 603 1.0 14 614 12 977 1.0 14 336 12 543 1.1 14 558 12 888 1.1 14 306 12 495 1.2 14 512 12 814 1.2 14 282 12 454 1.3 14 472 12 751 1.3 14 261 12 420 1.4 14 439 12 698 1.4 14 243 12 391 1.5 14 409 12 651 1.5 14 227 12 366 1.6 14 384 12 610 1.6 14 214 12 343 1.7 14 361 12 574 1.7 14 202 12 324 1.8 14 341 12 543 1.8 14 191 12 306 1.9 14 323 12 514 1.9 14 182 12 291 2.0 14 307 12 488 2.0 14 173 12 277 2.1 14 292 12 465 2.1 14 167 12 266 2.2 14 279 12 444 2.2 14 159 12 254 2.3 14 267 12 425 2.3 14 153 12 244 2.4 14 256 12 407 2.4 14 147 12 234 2.5 14 141 12 225 Speaker Wire Distance Guideline -25v& 70v 2.7 14 132 12 209 Max. Wire Lengt Max. Watts Gauge Volts h Volts Length The Truealert maximum distance is to the 5 18 25 3,330 70 26,108 farthest device on the Branch or Channel. 10 18 25 1,665 70 13,054 It is not the total distance of the Branch or 15 18 25 1,110 70 8,703 Channel circuit. 20 18 25 833 70 6,527 25 18 25 666 70 5,222 30 18 25 555 70 4,351 35 18 25 476 70 3,730 40 18 25 416 70 3,264 45 18 25 370 70 2,901 50 18 25 333 70 2,611 55 18 25 303 70 2,373 60 18 25 278 70 2,176 65 18 25 256 70 2,008 70 18 25 238 70 1,865 75 18 25 222 70 1,741 80 18 25 208 70 1,632 85 18 25 196 70 1,536 90 18 25 185 70 1,450 95 18 25 175 70 1,374 100 18 25 167 70 1,305 ®Simplex TrueAlarm® Analog Sensing UL, ULC, CSFM Listed;FM Approved; Addressable Duct Sensor Housings with TrueAlarm MEA (NYC)Acceptance* Photoelectric Sensor; Available with Multiple Relay Control Compact air duct sensor housing with clear ;pTM = -_ cover to monitor for the presence of smoke"' , `, Includes factory installed TrueAlarm (I : photoelectric smoke sensor and features: • Individual sensor information processed by the host control panel to determine sensor status • Digital transmission of analog sensor values via IDNetTM or MAPNET II®,2-wire communicationst • Programmable sensitivity,consistent accuracy, environmental compensation,status testing,and monitoring of sensor dirt accumulation Model 4098-9755: • Basic duct sensor housing(no relay output)powered by IDNet/MAPNET II communications Duct Sensor Housing, Front and Bottom View Model 4098-9756: • Duct sensor housing with supervised output for e E multiple remote relays;requires separate 24 VDC; includes one relay °• Relay output is under panel control• At the panel,relay output can be activated manually or in response to a separate alarm or other input 2098-9808 2098-9806 General features: Remote Status/Alarm Indicator and Test Station • UL listed to Standard 268A • - • • Clear cover allows visual inspection Operation.Simplex®compact air duct smoke sensor • Test ports provide functional smoke testing access housings provide TrueAlarm operation for the detection of with cover in place smoke in air conditioning or ventilating ducts.Sampling • Mounts to rectangular ducts or round ducts;minimum tubes are installed into the duct allowing air to be directed to size is 8"(203 mm)square or 18"(457 mm)diameter the smoke sensor mounted in the housing. • Magnetic test feature for alarm initiation at housing - . - • • Optional weatherproof enclosure is available - Digital Communication of Analog Sensing. separately(refer to data sheet S4098-0032) Analog information from the sensor is digitally Diagnostic LEDs (on interface board): communicated to the control panel where it is analyzed. • Red Alarm/Trouble LED for sensor status and Sensor input is stored and tracked as an average value communications polling display with an alarm or abnormal condition being determined by • Yellow LED for open or shorted trouble indication of comparing the sensor's present value against its average. supervised relay control(4098-9756 only) Intelligent Data Evaluation.Monitoring each Sampling tubes (ordered separately): photoelectric sensor's average value provides a software • Available in multiple lengths to match duct size filtering process that compensates for environmental factors(dust,dirt,etc.)and component aging,providing • Installed and serviced with housing in place an accurate reference for evaluating new activity.The Remote module options (ordered separately): result is a significant reduction in the probability of false • Remote red status/alarm LED(2098-9808) or nuisance alarms caused by shifts in sensitivity,either up or down. • Remote test station with LED(2098-9806) • 4098 9843 remote relays(refer to page 2 for details) i* Please note that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct.It is not intended ' These products have been approved by the California State Fire Marshal(CSFM)pursuant to to,and will not,replace smoke detection requirements for open Section 13144.1 of the California Health and Safety Code.See CSFM Listing 3240-0026.241 areas or other non-duct applications. for allowable values and/or conditions concerning material presented in this document.It is subject to re-examination,revision,and possible cancellation.Accepted for use—City of New t TrueAlarm sensors and IDNet and MAPNET II communications are protected by one or York Department of Buildings—MEA35-93E.Additional listings may be applicable;contact more of the following U.S.Patents:5,155,468;5,173,683;5,543,777;5,400,014; your local Simplex product supplier for the latest status.Listings and approvals under Simplex 5,543,777;5,710,541;D383,407;D388,352;D392,573;4,796,025. Time Recorder Co.are the property of Tyco Safety Products Westminster. S4098-0030-5 3/2007 Control Panel Selection.Peak activity per sensor is Typically duct sensor applications require less sensitive stored to assist in evaluating specific locations.The alarm settings(such as 2.5%per foot obscuration)due to the set point for each sensor is determined at the control ducts being a relative dirty environment.However,the panel,selectable as the individual application requires. standard seven levels of TrueAlarm sensor sensitivity are Sensor Status LED.Each sensor housing's red status available for each individual sensor,ranging from 0.2%to LED(located on the electrical interface board)pulses to 3.7%per foot of smoke obscuration. Sensitivity is indicate communications with the panel.If the control selected and monitored at the fire alarm control panel. panel determines that a sensor is in alarm,or that it is _ • dirty or has some other type of trouble,the details are annunciated at the control panel and that sensor housing's • Individual smoke sensitivity selection status LED will be turned on steadily.During a system • Sensitivity monitoring that satisfies NFPA 72 alarm,the control panel will control the LEDs such that sensitivity testing requirements an LED indicating a trouble will return to pulsing to help • Peak value logging allows accurate analysis for identify any alarmed sensors.(Remote Status/Alarm sensitivity selection LEDs track the operation of the sensor housing LED.) • Automatic,once per minute individual sensor ITrmflrTJ calibration check verifies sensor integrity TrueAlarm photoelectric sensors use a stable,pulsed • Automatic environmental compensation infrared LED light source and a silicon photodiode • Smoke sensitivity is displayed in percent per foot receiver to provide consistent and accurate low power • Ability to display and print detailed sensor smoke sensing. information in plain English language • Relays of model 4098-9756 are under panel control • _ • for ON,OFF,or override Duct Smoke Sensor Housing with Photoelectric Sensor* Model., Description Compatibility, Basic Duct Sensor Housing; operating power is supplied Simplex fire alarm control panel models 4010, 4098-9755 by 4020,4100, 4100U, and 4120.Also 2120 CDT if either IDNet or MAPNET II communications(no relay output) configured for MAPNET II,TrueAlarm operation Duct Sensor Housing with supervised multiple relay output, Same as above except relay operation is not compatible with 2120 CDT; 4098-9756 requires separate 24 VDC fire alarm power and 4081-9008 end-of-line resistor harness;includes one 4098-9843 relay Relay output is for up to 15 total 4098-9843 Relays(additional relays are ordered separately) Remote LED Indicator and Test Station, Select One if Required Model Description Compatibility Mounting 2098-9808 Red LED status indicator Use single gang box, Test Station with keyswitch and red LED status indicator 4098-9755 3"H x 2"W x 2"D 2098-9806 4098-9756 (turning switch to"TEST"initiates alarm for system testing) (76 mm x 51 mm x 51 mm) Epoxy Encapsulated Remote Relay and End-of-Line Resistor Model Description Compatibility Location Relay; single Form C(7 A @ 120 VAC); refer to pages 3 and 4 Locate relays within 3 ft 4098-9843 for additional relay information; one included with 4098-9756; 4098 9756 only; (1 m)of device being wiring is 18 AWG(0.82 mm2)color coded wire leads connect up to 15 controlled per NFPA 72 4081-9008 End-of-Line Resistor Harness; 10 kQ, 1/2 W; (ref. 733-894); required to supervise remote relay coil connection 4098 9756 At last relay location Each duct housing includes an internally mounted model 4098-9714 TrueAlarm photoelectric sensor and an exhaust tube.A correctly sized sampling tube(ordered per application)is required, refer to chart below. Overall Duct Width Tube Required Suggested Cut Length 12"(305 mm) 2098-9796 1/2"(12.7 mm)longer than duct width 13"to 23"(330 mm to 584 mm) 2098-9804 1/2"(12.7 mm)longer than duct width 24"to 46"(610 mm to 1168 mm) 2098-9797 2"(51 mm)longer than duct width 46"to 71"(1168 mm to 1803 mm) 2098-9798 2"(51 mm)longer than duct width 71"to 95"(1803 mm to 2413 mm) 2098-9799 2"(51 mm)longer than duct width 2 S4098-0030-5 3/2007 NOTE: Refer to Installation Instructions 574-776 for additional detail and maintenance information. P ,w�p.*"�" 11 3/8 (289 m ) - Conduit b others " 4098-9714 Smoke sensor,mounted ° in special interface base(supplied) r..M ��_ Metal plate with dual holes for 3/4"(19 mm)conduit,plug `� ---- „ ,® supplied for unused hole (171 mm) r3J+ Yellow LED relay control trouble Sampling tubek` indicator(4098-9756 only) access hole '� , Red sensor k status LED Side of duct � 33 Wrong terminals Stationary baffle(built in) Captive fastening screws(4) Magnetic test area ` r Mount as shown(preferred)or Transparent cover Gasketed sensor area with electronics area located to the LEFT or UP ONLY 3-3/8" (86 mm) _1k 7 I• • 13/16" Gaskets(supplied) (21 mm) Duct wall Test ports(2)provided Exhaust tube(supplied) for measuring airflow Sampling tube,ordered and for separately per duct width aerosol injection End View with Duct and Tubes Duct housing 18"Round duct outline 4098-9843 Remote Relay (minimum diameter) (7 A @ 120 VAC,for use with 4098-9756 only) ________ NOTE: Mount in separate electrical box within I_ I 3 ft(1 m)of device being controlled per NFPA 72 8"Square duct outline Exhaust tube I (minimum width) I \\ 13/16" (21 mm) J 1-1121 I Sam lin tube,ke ed for ro er hole all nment 1-3/16 (30 P 9 Y P P 9 (38 mm) mm) with holes facing into airflow(template is provided for proper tube installation) 3 S4098-0030-5 3/2007 hi II1Il!er .I*1r• Preferred Duct Sensor Locations: 1. A minimum of six duct widths downstream from Exhaust Sensor bends or inlets to avoid air turbulence. d Damper OK 2. On the downstream side of filters to detect fires in the Exhaust.— II ..Retum filters. LJ Air 3. In return ducts,ahead of mixing areas. Do not locate 4. Upstream of air humidifier and cooling coil. sensor here Retum air 5. With accessibility for test and service. damper 6. For additional information,refer to NFPA 90A, Standardfor the Installation ofAir Conditioning and Ventilating Systems. Fresh Supply air—' Air Locations to Avoid: Filter Sensor I. Where dampers closed for comfort control would Do not locate bank sensor here OK interfere with airflow. Bend or other 2. Next to outside air inlets(unless the intent is to obstruction � monitor smoke entry from that area). 3. In return air damper branch ducts and mixing areas Return air 6 Duct inlet s oust where airflow may be restricted. widths widths minimum ; minimum Outdoor Applications Note: For outdoor applications,refer to data sheet S4098-0032 for information on weatherproof enclosure 4098-9845. General Mechanical and Environmenfat ' Air Velocity Range(linear ft/min) 300 to 4000 ft/min(91 to 1220 m/min) Sensor Sensitivity Range 0.2%to 3.7%per foot of obscuration, selectable at host control panel UL Listed Temperature Range 32° F to 100°F(0°C to 38°C) Operating Temperature Range 32° F to 122°F(0°C to 50°C) Storage Temperature Range 0°F to 140° F(-18°C to 60°C) Humidity Range 10%to 95% RH, non-condensing Wiring Connections Terminal blocks, 18 to 12 AWG(0.82 mm2 to 3.31 mm2) Housing Color Black base with clear cover Remote Status/Alarm LED and Test Station with Remote Status/Alarm LED Remote Alarm LED Current 1.2 mA, no impact to 24 VDC alarm current(2098-9808 or 2098-9806) Test Station Keyswitch Current 3.3 mA, no impact to 24 VDC alarm current(2098-9806) Remote Alarm LED and Test Station Distance 250 ft(76 m)maximum Addressable Operation Data Communications IDNet or MAPNET II communications, auto-select,one address per housing; provides operating power to model 4098-9755 Model 4098-9756 with Supervised Multiple Relay Control,Requires Separate Fused 24 VDC from Fire Alarm Power Supply Input Voltage 18-32 VDC(24 VDC nominal) Standby Current 3 mA @ 24 VDC Alarm Current(one relay activated) 15 mA @ 24 VDC; add 15 mA for each additional remote 4098-9843 relay For use with 4098-9843 relay only,quantity of 15 maximum;distance of 500 ft Supervised Remote Relay Control Output (152 m)maximum; requires 4081-9008(ref. 733-894) 10 kc≥, 1/2 W end-of-line resistor 4098-9843 Relay Output Ratings,Single Form C,use with Model 4098-9756 Only Coil Current 15 mA @ 24 VDC, up to 15 maximum per relay control output Relay Contacts 7 A at 0.35 PF @ 28 VDC& 120 VAC 250µA@5VDC Location Distance 500 ft(152 m)maximum to relay coils; relays must be within 3 ft(1 m)of device being controlled per NFPA 72 Tyco,Simplex,the Simplex logo,TrueAlarm,IDNet,and MAPNET/1 are trademarks of Tyco International Services AG or its affiliates in the U.S.and or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association(NFPA). 93®Simplex Tyco Safety Products Westminster•Westminster, MA-01441-0001-USA S4098-0030-5 3/2007 www.tycosafetyproducts-usa-wm corn c 2007 Tyco Safety Products Westminster.All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. ®Simplex System Accessories UL, CSFM Listed; Fire Alarm Control Relays, Track Mount and MEA (NYC)Acceptance* Encapsulated; Model 4098-9843 and 2088 Series UL listed under Standard 864 as Control Unit Accessory (UOXX) Track mount package availability: • Single relay module or four relay module,with or er. without cover,with SPDT or DPDT contacts ��g Ar �" �x ? � • ��� �t • LED indicates relay module status • Cover provide status LED viewing ports • Multiple coil voltage inputs,diode polarized for DC • Modules are track mounted with snap-apart feature design allowing the four relay module to be separated 2088-9020 with Enclosure, osure( C, Four DPDT Relay Package (shown with cover removed) Single encapsulated SPDT relay package with color coded 18 AWG wire leads, available in two versions: • 2088-9021 (PAM 1)Provides diode polarized multiple input voltage ability and LED indication • 4098-9843 (PAM-SD)Provides a diode polarized 24 VDC coil with in/out wiring ' *i.i gi1IT1• APAC-PAM SD These multi-purpose control relays offer SPDT or DPDT, ""R� BE° 10 A(or 7 A)contacts in a variety of mechanical RED L°RG packages. Models are available for coil operation by one of four input voltages allowing a single relay to be Encapsulated Relay Package energized from a voltage source of 18-35 VDC or VAC, (typical of 2088-9021, PAM-1 and 4098-9843, PAM-SD) 120 VAC, or 230 VAC(not available with 4098-9843). Voltage selection is made by wiring to the appropriate input terminals or wire leads. • - . • -• Each relay model (except model 4098-9843)contains a Encapsulated Relays,see page 2 for dimensions red LED which indicates that the relay is energized. 18 AWG(0.82 mm2)color-coded Connections wire leads Mounting options are varied for application flexibility. Track mounted relays may be"snapped apart"from a Relay 2088-9021 standard four-module assembly and used independently if Contact Ratings 10 A @ 120 VAC, resistive desired. Coil Voltage 18-35 VACNDC, 120, or 240 VAC . - • Ratings Current 15 mA @ 24 VACNDC, &@ 120 or 230 VAC Track Mount Relays,see page 2 for dimensions Relay 4098-9843 Coil Voltage 18-35 VACNDC, 120, or 230 VAC 18-32 VDC input, polarized, 15 mA SPDT models= 18 mA Coil Ratings @ 24 VDC Coil Current DPDT models=40 mA 7 A at 0.35 p.f @28 VDC& Terminal Blocks Up to 14 AWG(2.08 mm2) Contact Ratings 120 VAC 10A@120VAC 250pA@5VDC Contact Ratings N.O. rated 1/6 HP, N.C. rated 1/8 HP Temperature Ratings 7A @ 28 VDC and @ 230 VAC UL Listed Range 32° F to 120° F(0°C to 49°C) Temperature Ratings Operating Range -58°F to 185° F(-50°C to 85°C) UL Listed Range 32°F to 120° F(0°C to 49°C) Humidity 85%RH Non-condensing Operating Range -58° F to 185°F(-50°C to 85°C) Humidity 85% RH Non-condensing `Product listings are by Air Products&Controls Inc.(www.ap-c.com)per model numbers shown on page 2.These products are also available through Space Age Electronics Inc. (www.1sae.com)with an SSU-prefix. S2088-0010-8 3/2006 date nc At�ro s P actF Pdn Ete ��` �`°111tc�ef,.; �..._T`.... � a among' •2088-9007 MR-101/T SPDT 3-1/4' H x 2-1/8"W x 1-1/2" D 2088-9009 MR-201/T DPDT Track mount, without cover One (83 mm x 54 mm x 38 mm) 2088-9008 MR-101/C SPDT 5-1/8"H x 3-1/8"W x 2-1/2" D Track mount with cover 2088-9010 MR-201/C DPDT (131 mm x 79 mm x 64 mm) 2088-9017 MR-104/T SPDT 3-1/4" H x 8-1/2"W x 1-1/2"D Track mount, without cover 2088-9019 MR-204/T DPDT (83 mm x 216 mm x 38 mm) Four 2088-9018 MR-104/C SPDT 5-1/8" H x 9-1/2"W x 2-1/2" D Track mount with cover 2088-9020 MR-204/C DPDT (131 mm x 241 mm x 64 mm) Encapsulated, multi-voltage coil, 1 1/2"H x 1"W x 7/8" D 2088-9021 PAM-1 color coded 18 AWG (0.82 mm )wire (38 mm x 25.4 mm x 22 mm) leads, with coil status LED NA SPDT Encapsulated, 24 VDC coil, color coded 1-1/2" H x 1-3/16"W x 13/16" D 4098-9843 PAM-SD 18 AWG (0.82 mm 2)wire leads (no LED) (38 mm x 30 mm x 21 mm) SPDT contacts rated DPDT contacts rated 10 A @ 120 VAC, resistive 10 A @ 120 VAC, resistive ® NC C NO® ® @ NC C NO NC C NO Relay energized LED 0 L0 0 ® ® L® ® ® ®1 0 18/24 115 230 ® ® 0 18/24 115 230 (18-35)VDC [7i (+) (18-35)VDC (-) (+) Coil voltage Coil voltage (note polarity (18-35)VAC AC AC (note polarity (18-35)VAC AC AC for DC) 120 VAC N V for DC) 120 VAC N V 230 VAC V V 230 VAC V V Terminal strip connections Terminal strip connections SPDT models DPDT models Tyco.Simplex,and the Simplex logo are trademarks of Tyco International Services AG or its affiliates in the U.S.andor other countries.Include any other pertinent trademark information here.i.e.:NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association(NFPA). f3®Simplex Tyco Safety Products Westminster• Westminster, MA•01441-0001 •USA S2088-0010-8 3/2006 www.tycosafetyproducts-usa-wm.corn S 2006 Tyco Safety Products Westminster All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. ®Simplex MAPNET II® Communicating Devices UL Listed; FM and Zone Adapter Modules (ZAMs) CSFM Approved* Addressable Interface to Conventional Circuits 1L JELT1 MAPNET II ZAMs provide an addressable interface • to conventional fire alarm zone circuit devices** including: • Initiating devices(Monitor ZAM) fl00#m s • Notification appliance circuits(Signal ZAM) • Control relays(Control ZAM) These ZAMs are compatible with the following Simplex fire alarm control panels when equipped with MAPNET II communications: • 4100/4100U Series fire alarm control panels Signal/Control ZAM • 4100 Series Universal Transponders • 4120 Series Network node fire alarm control panels • 4020 Series fire alarm control panels • 2120 Communicating Device Transponders ) tact MAPNET II communications can be wired: • NFPA Style 4/Class B or Style 6/Class A • Style 4/Class B communications may be wired either"T"tapped or In/Out Convenient DIP switch address selection UL listed to Standard 864 Monitor ZAM MAPNET II zone adapter modules (ZAMs)provide • "i•ij an addressable interface between conventional zone Control ZAMs provide addressable control functions devices and the host fire alarm control panel. such as elevator capture,HVAC control,pressurization Monitor ZAMs provide status monitoring and fan control, and damper control.The control relay supervision of an initiating device circuit(IDC)zone and provides a DPDT contact(contact ratings are shown on are used for circuits with non-addressable detectors and page 4). for other contact closures such as waterflow and tamper switches or non-addressable manual stations.Different • - • models of Monitor ZAMs are available for two-wire IDCs Class B,or Class A,and for four-wire IDCs with Class B Communications Supplied by MAPNET II, IDC input. Each type required a separate 24 VDC input 24 to 40 VDC with data power from a listed fire alarm power supply. Power Separate 24 VDC required from listed fire alarm power supply Signal ZAMs supervise and operate 24 VDC notification appliances,speakers,and telephone circuits. Output Wiring Information Refer to reference diagrams on pages 3 and 4 capacity is up to 2 A (@24 VDC,or 50 W of 25 VRMS speakers, or up to three simultaneously activated Wire Connections Screw terminals for in/out wiring, firefighter phones. The signal ZAM is available for either 18 to 12 AWG wire Style Y/Class B or Style Z/Class A operation for Address Means DIP switch,8 position notification appliance circuits. ern erature Range 32°F to 120°F(0°C to 49°C) T This product has been approved by the California State Fire Marshal(CSFM)pursuant to p g intended for indoor operation Section 13144.1 of the California Health and Safety Code.See CSFM Listing 7300-0026182 for allowable values and/or conditions concerning material presented in this Humidity Range Up to 85%RH at 86°F (30°C) document.It is subject to re-examination,revision,and possible cancellation.This product was not ULC listed or approved by MEA(NYC)as of document revision date.Additional listings may be applicable,contact your local Simplex product supplier for the latest status. °° MAPNET II addressable communications are protected by U.S.Patent No. 4,796,025. S2190-0012-14 12/01 Zone Adapter Modules, Monitor ZAMs (separate 24 VDC power is required) MQd < Caver Type Description upervtsory;Current, Alarm Current 2190-9153 Surface 2190-9154 Flush Monitor ZAM, Class A(Style D) 2190-9155 Surface Monitor ZAM, Class B (Style B) 20 mA @ 24 VDC 90 mA @ 24 VDC 2190-9156 Flush 2190-9157 Surface 4-Wire Detector ZAM, Class B IDC input 2190-9158 Flush Zone Adapter Modules, Signal and Control ZAMs (separate 24 VDC power is required) Model Coyer Type Description: Supervisory Current Alarm Current 2190-9159 Surface 2190-9160 Flush Signal ZAM, Class A(Style Z) 15 mA @ 24 VDC 65 mA @ 24 VDC 2190-9161 Surface Signal ZAM, Class B(Style Y) 15 mA @ 24 VDC 2190-9162 Flush 2190-9163 Surface 40 mA @ 24 VDC Control Relay ZAM, DPDT Contacts 10 mA @ 24 VDC 2190-9164 Flush 4-11/16" (119 mm) Square box, 2-1/8" (54 mm) deep 0 1 Typical ZAM assembly 1 O J (� o O o $E O 4-11/16" (119 mm) O Square extension ring, L1 J 1-1/2" (54 mm) deep Flush cover, 5-7/16" ex O square (138 mm) Surface cover, 4-15/16" square (125 mm) 2 S2190-0012-14 12/01 24 VDC + Monitor Class B,Style B ZAM 2-Wire monitor circuit "T"Tapped + or IN/OUT MAPNET II wiring _ communications Shield Monitor Monitor circuit circuit Resettable Return Detector power End of line relay Class A/Style D 4-Wire detector 2-Wire monitor circuit ZAM wiring + 24 VDC Class B/Style Y notification appliance circuit(speakers shown for reference) "T"Tapped or MAPNET II IN/OUT wiring communications Shield Signal input,audio or phone 0- Primary • Class A/Style Z notification appliance circuit Return Signal input,audio or phone 3 S2190-0012-14 12/01 Control ZAM 24 VDC Common 1 'T"Tapped or MAPNET II IN/OUT wiring communications N.C.2 Shield Common 2 Controlled device Control Power Applicationt Resistive Rating inductive Rating** Power Limited* 2 A @ 28 VDC 1 A @ 28 VDC 2A@28VDC 1A@28VDC Non-Power Limited 1/2 A @ 120 VAC 1/2 A @ 120 VAC * DC Voltage must be from a listed Fire Alarm power supply. ** Inductive loads must be properly suppressed. Tyco,Simplex,the Simplex logo,and MAPNET 11 are trademarks of Tyco International Services AG or its affiliates in the U.S.and or other countries. ®Simplex Westminster,Massachusetts 01441-0001 USA www.simplexnet.com S2190-0012-14 12/01 2.2001 Simplex Time Recorder Co.DBA TEPG-CIS(a Tyco company).All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice.