Loading...
HomeMy WebLinkAbout08-8013 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 8013 FIRE ALARM SYSTEM PERMIT Permit Number: 8013 Address: 6712 DAIRY RD Permit Type FIRE ALARM SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 02-26-21-0010-03800-0000 Improv. Cost: 6,731.25 Date Issued: 10/01/2008 Name: LUSARE INVESTMENT HOLDINGS LLC Total Fees: 200.00 Address: 28804 FALLING LEAVES WAY Amount Paid: 200.00 WESLEY CHAPEL, FL 335435761 Date Paid: 10/01/2008 Phone: (813)679-1883 Work Desc: INSTALL FIRE ALARM SYSTEM A TOTAL SOLUTION,INC ALARM INSPECTION FEES V 50.00 50.00 FIRE PLAN REVIEW FEES V 100.00 FIRE Ib2 .�v FIRE ACCEPTANCE Final FIRE ELEVATOR RECALL Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." a., CONTRAC IGN I IC R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- Fire Marshal Office- 813-780-0041 Licensing Portal - License Search Page 1 of 2 F:cria) vrrrent q i BusJneS Profess na! Regulation DBPR ONLINE SERVICES Log On Home i Help i Site Map 95824 AM 9118/2008 Public Services Search for a Licensee Apply for a License Data Contained In Search Results Is Current As Of View Application Status 09/16/2008 10:00 AM. Apply to Retake Exam Find Exam Information Search Results File a Complaint Please see our glossary of terms for an explanation of the AB&T Delinquent license status shown in these search results. Invoice &Activity For additional information, including any complaints or List Search discipline, click on the name. User Services Renew a License License Name License Change License Status Name Number/ Status/Expires Maintain Account Type Type Rank Change My Address Certified View Messages Alarm ROBINSON, EF0000441 Current, Active Change My PIN System JOHN S Primary Cert Alarm I 08/31/2010 View Continuing Ed Contractor I License Location 3531 KEYSTONE RD TARPON SPGS,FL Address*: 34689-9498 Term Glossary 3531 KEYSTONE RD TARPON SPGS,FL Main Address*: 34688-7815 Online Help (FAQs) Certified Alarm ROBINSON, Primary EF20000480 Current, Active System JOHN S Cert Alarm I 08/31/2010 Contractor I License Location 26774 HICKORY LOOP LUTZ,FL 33559 Address*: Main Address*: 3531 KEYSTONE RD TARPON SPGS,FL 34688-7815 Real Estate ROBINSON. BK3121044 Current, Active Broker or JOHN S Primary Broker 09/30/2010 Sales License Location 5300 TIMUCUA CIRCLE SAINT AUGUSTINE, Address*: FL 32086 Main Address*: 5300 TIMUCUA CIR SAINT AUGUSTINE,FL 32086 Real Estate ROBINSON, SL526542 Null and Void, Broker or JOHN Primary Sales O9/3O/2OO4 Sales SMYRE Associate Main Address*: 2270 COACH HOUSE LANE NAPLES,FL 34105-2713 Certified ROBINSON. CGC052769 Current, Active General JOHN Primary Cert General 08/31/2010 Contractor STEPHEN License Location 2718 NW 31ST AVE FT LAUNDERDALE,FL Address*: 33311 Main Address*: P O BOX 5543 FT LAUDERDALE,FL 33310 Real Estate ROBINSON, Primary Broker or JOHN BK3005411 Current, Active https://www.myfloridalicense.com/wll 1.asp?mode=3&search=Name&SID=&brd=&typ= 9/16/2008 ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Fire Chief Keith Williams Bus (813)780-0041 Fax (813)780-0044 FIRE SERVICE USER FEES Occupancy No.: JO Plan No.: Z> Contractor. 1 0 r- c C Billing. Address: Business Name: 1f a$ Business Address: Business Phone No.: Billing Phone No.: '- Business Fax No.. Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE 8 Site Plan N/C Annual N/C Sprinkler $50 1st Alarm N/C Muni-Famiy/Commercial .06 sf 1st Re.inspection N/C Standpipes $50 2nd Alarm N/C (Minimum Charge$25.00 2nd Re-inspection $100 Fire Pump $50 3rd Alarm N/C Plan Revisions DBL 3rd Re-inspection $250 Hoods $50 4th Alarm $100 4th Re-Inspection $500 Fire Alarm 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until LP Gas 6th Alarm $200 8 0-25 Heads $50 violations corrected) Natural Gas $50 NON COMPLIANCE $150 26 plus Heads $100 SPRINKLER SYSTEMS Fuel Tanks- pertank $50 STANDPIPE SYSTEM Hydro Undergrounds $45 Sparklers $100 0 Per Riser $50 Hydrostatic Test $65 per system Fire Works $500 FIRE PUMP Acceptance Test $45 persyseem Camp Fire $25 Per Pump $100 Hydrant Flow $75 Controlled Bum $100 FIRE ALARM SYSTEM Hood/Duct $50 -25 Devices $50 FIRE ALARM SYSTE Place of Assembly $50 Annual 26 plus Devices System Acceptance $50 Fire Protection $25 SUPPRESSION SYSTEMS U Recall Acceptance Flammable Application $50 Annual Wet $50 OTHER Waste Tire Storage $50 Annual Dry $50 Fire Wall/Smoke Wan $15 perwall Generator<KW $100 CO2 $50 LP Gas $25 per tank Generator>30 KW 150 Other $50 Natural Gas $25 per system Bio-Hazard Waste $100 Annual KITCHEN EXHAUST Fumigation Tenting $50 Hood/Ducts $50 Tent 10x10 or greater $15 pertent Torch Pot/Applied $50 OTHER U Fire Pump $45 Haz.Materials $100 Annual 8 LP Installation per tank $50 J Fire Suppression $30 Fuel Tank Installation $50 System Acceptance (Per Tank) $50 8 Exhaust Hood/Duct $30 Natural Gas Installation $50 Re-inspection DBL (Per System) (other than annual) Spray Booth $50 Inspection scheduled DBL and cancelled less than 24 hours 8 Construction Insp. N/C Emergency Vehicle Ac' $50 FALSE ALARM PLANS TOTAL INSPECTION TOTAL~ PERMIT TOTALHg" L TOTA GRAND TOTAL 1 — i Comments: Date: F_ InsRtctor. 1vvy i/ir/L_ ' ,' jt' Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (813) 780-0041 Kerry Barnett Fax(813) 780-0044 June 27, 2008 I have reviewed and approved the plans for a fire alarm system addition located at 6712 Dairy Rd. I have attached the comments for the plan approval. If there are any questions please contact my office at 813-780-0041. 1. System to be installed in accordance to NFPA 72,2007 edition. 2. Add smokes to upstairs file room and downstairs closet/storage rm. 3. Double backflow preventor shall have tampers. 4. Make sure batteries are dated and phone jacks are marked. Be sure batteries are sufficient size if any of these comments reflected a need to change. 5. Strobes to remain on when system is silenced. 6. Pulls, duct detectors and smokes shall be labeled for identification. Shall match what panel states. Zone maps shall be located at annuciator and panel. Inspections Required 1. Acceptance test. 813-780-0020 City of.Zephyrhills-Fire• O() Fax-813-780-0021 Permit Application Date Received 2 -Dg Phone Contact for Permit 7 2 7 Z Owner's Name LV 5-ArG ve.yr,v er4. - o L).. L Owner's Phone Number CI Owner's Address, /2,, O L( I A '',fin A/C sliC.ha FL 33>Lj 3 Fee Simple Titleholder Name I Titleholder Phone Number Fee Simple Titleholder Address Job Address J 2 L I S L__3_ 92 Lot# Sub Division Parcel# 02. 26 Z.1 UDIO L)3? JO 3000.<. Bio-Hazard Waste Storage-ANNUAL Fumigation Tent Comm Exhaust Kitchen Hood/Duct Hazardous Material(Tier II or RQ Facility)ANNUAL Controlled Bum Hood Installation Emergency Generator<30 kw LP/Natural Gas-Installation Emergency Generator>30 kw LP/Natural Gas-ANNUAL Sale Fire Protection Maintenance-ANNUAL Places of Assembly-ANNUAL r y emi ®nOther Sprinkler � 0 ❑ 0 Recreational Bum Fire Alarm � ❑ 0 0 I Sparklers Hood Cleaning � 0 0 ❑ II L1 Sprinkler System Installations Hood Suppression ❑ ❑ ❑ I I [ ] Standpipes(Sprinkler Sys) Fire Alarm Installation El Torch Roofing/Tar Kettle ElFire Pumps El Waste Tire Storage ANNUAL Fire Works Flammable Application-ANNUAL ? ,2-5 Valuation of Project Fuel Tanks Q Other: Contractor /J Company Tc ro.( „ , . Signature (f Registered /N Fee Current /N Address 353 j Kt f to^e 1i Ta 5 r 1 (, 3 ij(, I License# EF 00 cc LtL) ELECTRICIAN Company Signature Registered Y/N Fee Current I Y/N Address j License# PLUMBER Company Signature Registered Y/N Fee Current Y/N Address License# MECHANICAL Company Signature Registered Y/N Fee Current Y/N Address License# OTHER Company Signature Registered Y/NJ Fee Current Y/N Address License# Directions: Fill out application completely. Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement is required(Mechanical work over$5000) Supply two(2)sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com) NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject,to-"deed°restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for-compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired -a-contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements mar:apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT i L2i __/L CONTRACTOR -' � Subscribed and sworn to(or affirmed)léfore me this Subscribed and swom to(o armed)before me this by by Who is/are personally known to me or has/have produced Who islare personally known to me or has/have produced as identification, as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped Search Again Show Map Building Schematic Unavailable Estimate Taxes Frequently Asked Questions Other Agency Data: Tax Collector School Board Supervisor of Elections Data Current as Of: Weekly Archive - Saturday, June 21, 2008 Parcel ID 02-26-21-0010-03800-0000 (Card: 001 of 001) Classification 10 - Vacant Commercial Mailing Address Assessment(totals) LUSARE INVESTMENT HOLDINGS LLC Ag Land $0 28804 FALLING LEAVES WAY Land $103,116 WESLEY CHAPEL, FL 335435761 Building $0 Physical Address Extra Features $1,048 6712 DAIRY RD ZEPHYRHILLS, FL 33542-6637 Total Assessment $104,164 Leaal Description (First 4 Lines) Save Our Homes $0 ZEPHYRHILLS COLONY COMPANY LANDS PB 1 PG 55 WEST 261.60 Taxable Value $104,164 FT OF TRACT 38 EXC WEST 15 FT THEREOF FOR RD R/W&EXC SOUTH Land Detail (Card: 001 of 001) Line Use Description Zoning Units Type Price Condition Value* 1 1000 COMMERCIAL 00OP 12,000.00 SF $3.98 1.00 $47,760 2 1000 COMMERCIAL 00OP 38,000.00 SF $1.33 1.00 $50,540 3 1000 COMMERCIAL 00OP 4,418.00 SF $1.09 1.00 $4,816 Additional Land Information Acres 1.25 Tax Area 30ZH FEMA Code X Commerical Code MDRD7AA Building Information (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features(Card: 001 of 001) Line Description Year Units Value 1 PAV ASP 1988 5,175 $1,048 Sales History Previous Owner LEON RAFAEL I&LYNNE A Year Month Book/Page Type Amount 2007 07 7569/ 1168 WD $375,000 1996 12 3680/ 1678 WD $145,000 1988 06 1712/0816 WD $79,900 Search Again Show Map Building Schematic Unavailable Estimate Taxes Frequently Asked Questions Other Agency Data: Tax Collector School Board Supervisor of Elections 1111111 11111 11111 11111 11111 111111111111111111111111111111111 2008143393 NOTICE OF COMMENCEMENT Rcpt: 1206193 Ree: 10.00 ?ermit N'o. DS: 0.00 IT: 0.00 ?arcel 1.D.No. 02 2 0010 03800 0000 10/01/08 Dpty Clerk ri E UNMERSICiN&i hereby gives notice that improvements will be made to certain real property, and in accordance with Section 713 of t ,/ .1orida Statutes,the following information is provided in this Notice of Commencement. 1. Description of property(legal description):ZEP RfflLLS COLONY CO LANDS PB 1 PG 55 W 261.60 FT OF TRACT 27 EXC W 15FT TEEREOF FOR RD R/W&EXC S a)Street(job)Address: 6712 Dairy Rd,Zephryhiils,FL 33542 JD PITTMAN ppASCO COUNTY CLERK '•General description of improvements: Installation of a Fire Alarm System 1 r73 m 1 of 1 OR BK 7X3 f PG 1877 I.Owner information a)Name and address: Lusare Investment Holding LLC 28804 Falling Leaves Way,Wesley Chapel FL 33543 b)Name and address of fee simple titleholder(if other than owner) c)Interest in property: Owner Contractor a)(name and address) A Total Solution Inc—3531 Keystone Rd,Tarpon Springs FL 34688 b)Telephone No.;727-942-I993 Fax No.(Opt.) 727-943-5919 Surety Information a)Name and address:N/a b)Amount of Bond: c)Telephone No.: Fax No.(Opt.) 6.Leader a)(name and addae s) b)Telephone No.: Fax No.(Opt.) Identity of person within the Sate of Florida designated by owner upon whom notices or other documents may be served: a)Name and address: b)Telephone No.: Fax No.(Opt.) In addition to himself,owner designatae'tl#e following person to receive a copy of the Lienor's Notice as provided in Section 13.13(1)(b),Florida Statutes: a)Name and address: b)Telephone No.: Fax No.(Opt.) Expiration date of Notice of Commencement(the expiration date is one year from the date of recording unless a different date is )Deified): ARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AF tIrR TIE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IPROPER PAYMENTh UNDER CHAPTER 71.3,PART 1,SECTION 713.13,FLORIDA STATUTES, WROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMtNT MUST BE EECOfDED AND POSTED ON THE JOB SITE BEFORE THE FIRST rSPENrJON.IF OU INTEND TO OBTAIlY b'INANCn�iG,CONSULT YOUR LENDER OR AND ATTORNEY BEFORE COMMENCING WORK OR R.ECORDfl DUR •)UR NOTICE OF COMMENCEMENT. 'ATE OF)MORD)A 5UN•TY OF PASCO 10. Signatu er Owner's Au-thorized Offlcer/Direetor/PartneriManager ll Z Print Name ) se foregoing instturuent fives acknow,}ed ed before tnc ihi � y of 08,by ,as � typ�f�t�ori�ty,e.g.officer,>zuste torney itt fact r Sa ri +�. me of party on behalf of who from was ecute orally Knawn or Produced Identification pe on Produced lorida pub * Bobbie J Knight My Comniissi0 My Commission DD764225 orM1 Expires 03/31/2012 arification pursuant to Section 92.525, Florida Statutes. Under penalties of perjury, I declare the ve r ad the foregoing and that the fac Res in it are true to the best of my knowledge and belief. IC a P a Above STATE CF FLORIDA COUNTY OF PASCC THIS IS TO CERTIFY THAT THE FOREGOING IS A TRUE AND CORRECT COPY OF THE DOCUMENT ON FILE OR OF PUBLIC RECORD IN THIS OF HAMp ANO EFiC AL SEAL WITNESS MY �V DAY OF frl4's P 7T AN,CLERK DF CI CI COURT ��. cf OEPUTY CLERK A TOTAL SOLUTION, INC 3531 KEYSTONE RD TARPON SPRINGS, FL 34688 FIRE ALARM LICENSE: EF0000441 LICENSE HOLDER: JOHN S. ROBINSON PHONE NUMBER: (727) 942-1993 PROJECT: 1E2785 MEDICAL OFFICE PEDIATRIC PARTNERS 6712 DIARY RD. ZEPHYRHILLS, FL. 33542 DESCRIPTION OF WORK FIRE ALARM SYSTEM 1J A TOTAL SOLUTION,ternsTot INC . Total Systems egrat Installation, Sales,Design and luspections Fire Alarm/Fire Sprinkles/Fire Hydrant/Secwty�i CCTV(closed circuit TV)/Nurse Call �/Access and Intercom Control/ -;;x'l 5 State Fire Sprinkle,License#92353800012002 State Fire Alarm License#FF0000441 W W .atotaisolutin.caxn Ryman Construction of Florida* Inc. "ONE CALL DOES IT ALL" 36413 SR 54 Quote No: 7296 Zephyrhills, Florida 33541 Date: 11/13/2007 Attention: Richard Burkan Page: 1 of 3 A Total Solution, Inc. is pleased to offer the following fire alarm system installation the location,Medical Office Complex for Pediatric Pamers, Zephproposal at All equipment installed by ATS meets the NFPA 101 (2003), NFPA 72 3112 Authority Having Jurisdiction ( 2) standards and the The proposal is as follows; nti i 1 Addressable fire alarm control 1 Multiplex Expender LCD Keypad for O7024 1 120V Circuit Protector 2 Phone Line Surge Protector 3 Multiplex pull station 6 Multiplex P/E smoke detector head 5 2 Wire smoke detector base 2 Multiplex single input fire mod 10 Multi-Candela Audible Visual Device (White) 5 Visual Device Multi Can,Strobe (White) The cost for this installation will be cable, .boxes, and hardware $6,731.25 . This pricey includes all parts (Incluging )! labor, permits and state sales tax if OPPlicable. 3531 KEYST0?M ROAD T4 1O,j SSPRWCJS, FLORIDA 3468$•7816 1 OCAi (727)9429s C.ENTR PLOan14MAT&FAM FAX(127)943-5919 • A TOTAL SOLUTION INC . Total Systems tntegati Installation, S Finlrj /Fire Hydrant litre Alarm/Fire S r �,�8�and Iaspeckiol�s p e r rant/Security Alarm/Access Control/ CCTV(closed circuit TV)/Nurse can and Intercom State Fire Sprinkler License#92353$00012002 State Fire Alarm License#EF0000441 ntiv<V.atotalsolutAon.corn Ryman Construction of Florida, Inc. "ONE CALL DOES IT ALL" 36413 SR 54 Quote No: 7295 Zephyrhills, Florida 33541 Date. 91/13!2007 Page: 2 of 3 The customer is responsible for providing a 120 volt dedicated circuit for the fire alarm s stem and necessary electrical boxes Installed. y The fire alarm system will have a one year warrant),on parts and labor. The warranty will be voided if the system is found to be misused or abused and/or an act of nature occurs. Please allow 4 to 6 weeks for permitin . (if req ired) Permit fees are subject to Change. We reserve the fight to adjust our price if this occurs. This proposal Is for the installation of a fire alarm system. The system will be manufacture Bosch and will be configured into the fire sprinkler system. d by Fire pull stations will be located at every exit. Smoke detectors will be installed over the annuciator panel, fire panel, in brea safe room and mechanical rooms. Vg � I � Q^ k room, computer � T gyrl;5 �k � �t��G l GIDaE:'F The installation of audible visual devices will comply with the NFPA 72. ATS will configure the mechanical contractors duct smoke detectors into the fire alarm The elec�gal contractor will be responsible for providing (1) 115 system. volt dedtc�t�d CitcUit. vim . S..`AC ss 3531 kCE STONE ROAD TARPON SPRINGS, FL+U )A 3468&78!3 LO A!(72)942.j993 C TrRA[, A 1.888-ATs-FIRE FAX(727)9433919 IFA TOTAL SOLUTION,Total sysccros rixc aline. INC. - flInstallation,Sales,lesin and Inspections Fire Almon/Fire Sprinkler/Fire Hydrant/Security Alum/Access Control/ CCTV(closed circuit TV)/Nurse Call and Intercom State Fire Sprinkler License#92353800012002 State Fire Alarm Licc>E t#EFO0004 41 WVVW-atotalsolutiaa eo�nu Ryman Construction of Florida, Inc. ONE CALL DOES IT ALL' Quote No: 36413 SR 54 7295 Zephyrhills, Florida 33541 Date: 11/13/2007 Page: 3 of 3 installation Terms The customer is responsible for all wall and/or ceiling repairs that may be necessary for fire alarm system access and installation purposes. ATS will be responsible for any drywall damage that Could Occur during this installation.When applicable the air conditioning contractor is responsible for the wiring of duct smoke detectors for system shut down purposes and the electrical contractor is responsible for the installation of the shunt trip devices when elevator shut down is required. if additional equipment is requested, that cost will be negotiated prior to the installation. Fire Alarm Monitoring ATS will provide monitoring of the alarm system for$32.00 per month (plus sales tax billed quarterly) Please initial below to have your fire alarm system connected to the central station for monitoring. Fire alarm monitoring requires two phone lines at the building. Customer Initials ins a ion Parr nt le: 10% Upon acceptancjc,iL at c t. (Permitting, 80% (Progress pay nts en all elec tricalp wgirne has desE Seais) completed for ea oor, a or milestone, been1086 Baler d > er finspectlon accepted by the Atij. This proposal is valid for 30 days. If you should have any questions, please give me a calf. Sincerely, ��� Acceptances: Charlie Ragghienti Director of Sales C-i A c4�2IZ '-i--- 2_--, Customer Name(Please Print) Cuatom Contract Amount signature $6,731.26 _ Date 393 y'STONE ROAD TARPON SPRINQ$ PLO A 346864 li LOCM(727)942,1943 CEN4L pLORJAA,1-8$8-AT8- PAX(721)943-5919 FireGuide D7024 Battery Calculation Company: A-TOTAL SOLUTION,INC. Address: 3631 KEYSTONE RD. Project Name: PEDIATRIC PARTNERS City: TARPON SPRINGS Project Number: £2785 State: FL Zip: 34888 Date: 8/20/2008 Phone: (727)942-1993 Designer: GTB Fax: (727)943-6918 Standby Hours: 24 Alarm Mine: 15 Quantity Device Standby Alarm Each Total Each - Total Fire Mann Caabot Panel 1 D7024 Fire Alarm Control Panel 4 Zones Expandable to 8 0.200 0.200 0.380 0.380 1 D7039 Multiplerr Ex a nder for the D7024 0.150 0.150 0.150 0.150 Total Control Page!Standy Current. 0.350 Alarm: 0.530 Oon Bus Devices 1 D7033 Alphanumeric LCD Keypad 0.080 0.080 0.100 0.100 Total Option Bus Standby Current 0.080 Alann: 0.100 MUX Bus Devices 2 D7044M Mini Single Flit IrW Modtle 0.000550 0.001100 0.000550 0.001100 3 07045 Addressable Sigte Action Pull Station 0.000550 0.001650 .0.000550 0.001650 5 07050 Photoelectric Smoke Deleclor/Base 0.000600 0.002500 0.000580 0.002800 Tote!MUX Bus Standby Current: 0.006250 Alann: 0.006650 Nodleadon 6 Wli-30cd 0006 0.050 0.132 0.792 10 w-is c 0004 0.041 0.109 1.090 Total Noocailion Applance Standby Current: 0.091 Alarm: 1.882 System Total Fire Alarm Control Panel(D7024) 0.360000 0.630 Miscellaneous Accessories and Expanders 0.000000 0.000 Option Bus Devices 0.080000 0.100 MUX Bus Devices 0.006250 0.006 2-Wire(Loop Power)Devices 0.000000 0.000 4-Wire(Smoke Power)Devices&Accessories 0.000000 0.000 Other(Aux Power)Devices 0.000000 0.000 Notification Appliances 0.091400 1.882 Trial Standby Current CaicNiled: 0.627 X Standby Hours Requied(24) 24 Standby Amp-Hous Cal alaled: 12.040 Total Alarm Current Ca colaed: 2.518 X Almm Minikes(15)180 0.250 Alarm AnipHou s Calalded: 0.628 Total Amp4lotrs Cebtlaed 13.269 a[E cs L X Derating Factor of 1.2 1.200 Minimum Battery Si lets'-1tr9$ � Battery Size Selected: 18 AH "~� D7024 24V Fire Control/Communicator Specifications Features Conventional Features • Four conventional zone(expandable to eight)Fire Alarm Control Panel(FACP) • Built-in Digital Alarm Communicator Transmitter (DACT) • 4 Programmable authority levels • Each detector zone supports up to 20 two-wire smoke detectors • Up to 18 programmable relay outputs • 32 character backlit LCD display • Supports up to four D7033 Fire System Controllers and eight D7030X Series LED Annunciators • Two Notification Appliance Circuits(NAC)on board O7024 Fire Control/Communicator • Internal 24VDC,4 an NAC power supply • through front panel interface or A viewing port in the keyed panel enclosure door leaves remote Programmable Fire System Coned interface ler the system status LEDs and LCD display visible while mai�ining system control key security. • 99 event history buffer Unlocking the enclosure door provides access to the • Option Bus provides serial data interface for fire system keys for silencing alarm and trouble conditions, alarm accessories zone bypassing,detector resetting,testing,and other • UL Listed for fire applications fire functions as well as programming.These functions • Compatible with RAM IV are also available on all D7033 Controllers connected to • WheelockTM Signal Sync the system. Multiplex Features D7039 Al system controllers provide custom text annunciation P ( ) on a 32 character,bacidt,two-line LCD display.All • Expandable to 255 addresses using multiplex system controllers also have built-in sounders. Back- technology light intensity and sounder volume are programmable. • Relay outputs expandable to 58 16 Personal Identification Numbers(PIN)are available • 499 event history buffer for access to system control. Each number can be • PINs available for up to 100 system users an authority level to limit system control • Compatible With RAM IV fu ons that may be armed. The system stores events in a 99-event memory log. Description The D7024 Communicator reports to two telephone numbers with full single,double,and backup reporting Conventional 07024 FACP and c omm rricates in BFSK,SIA,Contact ID,Modem The Radionics O7024 is a fully integrated FACP Than Ilia'and 412 and 311 Tone Bursts. provides four zones and is capable of supporting both The D7024 enclosure has space for additional two wire and four-wire detectors.Each zone can essoiy modules and two D1218 12V, 17 Ah batteries support up to 20 two-wire detectors,or any number of or two D126 12V,7 Ah batteries. four-wire detectors(depending on available power). Multiplex Technology(D7039) Two Notification Appliance Cu-cuts(NAC)provides up The O7024 conventional be to 4 amps of 24-volt power to operate horns,strobes, version features 2.02 res can r bells,and other notification appiarices.Each NAC can enhanced,when or higher be programmed to provide the WheelodkTM' fimrware with the addition of a D7039 Multiplex Senchroamed Output on Module.The D7039 expands the base system up to 255 addressable points,increases the System control can be accessed through a built-in user number of relay outputs to 58 and adds an additional interface in the panel,or through the remote D7033 Fire 400 events to the history buffer for a total of 499 events. System Controllers connected to the system. The D7039 also allows for up to 100 system users(an addition of 84 PINs from the base system). A member of the radionics Bosch Group D7024 Application Ttm D7024 con be used in corruriercial and pubic FNumbw re +32•to 120'F to building applications such as schools,universities, manufacturing plants and health care faciNes. It is listed by UL for Central Station,Local,Auxiliary and naling Two C B,Style 4SLC'sRemote Station Systems SLC) (can be combined into one Class 6 cIrcuit) Installation woo 15 in. .1 cm) The 07024 enclosure and the CerdrollComnwricstor Nelit20.8 at(52.7 cn are shipped together. All mounting hardware necessary 4.3 n. 10.8 cm for mounting the Contrd/Communic a or m the enclosure is included.The control panel must be installed in 07033 Kaw.de Four(max.) accordance to the National Electrical Code(NFPA 70), 0703oX Series Eight(max.) the National Fire Alarm Code(NFPA 72)and the Authority Having Jurisdiction. Wore Type #18 AWG(min.);four-conductor F.P.L. Specifications erg 4,000 ft 1,219.2m max. a x Listings and Approvals Input 120 V.60 Hz,1.5 1.5A max x • Underwriters Laboratories UL 864 A hrsed • CSFM NAC 24 VDC nominal 4 A;circuit :2.5 A. � 12-92-E Vol.VII Auxiliary 24 VDC nomea unlillered 1.0 A • NYC-MOption Smoke 2412 VDC 500 m& Ordering Information fy NAC Outputs 2 on-board D128 12 V 7 Ala (6 in.x 2.6 in.x 3.94 in.) NAC Wtring Standard Class B,StyN Y opNation.use 07015 for Class A.Styts Z 0185 Reverse Polarity SigneBag Module x- 0275 End Of Line Power Supervision Module On-board Relays Two Form"C"relays rated at 5 A, D1218(2) 12 V,17 Ah Battery 2$VDCeach (7.13 m.x3 in.x6.63in. Off-board Relays Up to two 07035 Octal Relay Modules 07014 Class A Zone Converter providrg eight Form'C'relay outp& 07015 Class A NAC Converter each.Contacts raMd at 5 28 VDC. D7024 24VOC Fire ControUCommunicator D7030X Eht Point LED Annunicator Number of 2- Four curls,expandable to eight using D7030X-S2 Eight Point LED Annunicator Wire Circuits a 07034 Four Poi t Expander Module. Yellow,6 Red) Circuit Type Class B,Style B(use a 07014 for D7030X-S8 Eight Point LED Annunicator Class D YeIo EOL Resistor 2.21 K ohms PM:25899,UL 07031 Silence Reset Module Supervisory 8-20 mM 07032 8 Zone LED Annunciator Expander Current 07033 LCD Fire System Controller Keypad Required Alarm 25 mA 07034 Four Point Expander Current D7035/8 Octal Relay Module/Box Max.Short 44 mA D7035 LCD Annunicator Circuit Current Silence and Reset Key enabled) Max.Line 150 ohms 07038 Remote NAC Power Supply Resistance D7039 llax Expansion Module Circuit Voltage 20.4—282 VDC D /g Mdl ,1ex Eht-hiputRemote Module Ran a Octal Driver Max.Detectors 20 detectors" ' D70481B-rrire) 07060 Photoelectric Smoke Detector wl Chamber Total r Pont Check Chamber Sensing y Current ren 3,M max. D705 0Th pho Smoke Detector W/H' Standby High Response Time Fast=0.5 sec:pregramnable ham 1 to Temperature Sensing&Chamber Check 89 seconds Dirty Chamber Sensng 7050.86—6 n.Base Required) D343 Mtitplex Duct Smoke Detector ®2002 Radionics,a division of Detection Systems, Inc. 43334B 2/02 PO Box 80012,Salinas, CA 93912-0012, USA Specifications 07024 Customer Service:(800)538-5807 Page 2 of 2 D7039 Multiplex Expansion Module Specifications Features • Multiplex (Addressable) Point Expansion Module • Compatible with O7024 Fire Alarm Control/Communicator (with version 2.0 or greater firmware installed) • Provides 2 two 4Mre (Class B, Style 3.5)multiplex buses • Provides 1 four-wire (Class A, Style 6) multiplex bus (supports Addresses 9-128) • Adds 240 additional addressable input points • Expands number of user codes to 100 PINs • Increases Event History Buffer to 499 events • Compatible with RAM IV • Easy to install Description The Radionics D7039 is a Multiplex Expansion Module designed for use with the D7024 Fire Alarm Control/ Communicator with version 2.0 or greater firmware installed. The D7039 connects directly to the control/communicator. It adds an additional 240 addressable input points to the base D7039 Multiplex Expansion Module system (eight conventional points + 240 addressable points, 248 points total). The D7039 also increases the number of Application relay outputs to 58,adds an additional 400 events to the history buffer for a total of 499 non-volatile events and also allows for The O7039 Multiplex Expansion Module is designed to up to 100 system users(an addition of 84 PINS from the base enhance the conventional features of the 07024 Fire Alarm system). Control/Communicator. The O7039 can be programmed remotely from a laptop or PC using the RAM IV Remote Account Manager software utility. Installation The D7039 mounts onto the control/communicator board inside of the panel's enclosure via connector pins. An I/O module mounts to the inside wall of the enclosure for field wiring. Instal,test and maintain this device according to its installation guide. NFPA 72, Local Codes and the Authority Having Jurisdiction. Failure to follow these procedures may result in failure of the device to operate properly. Radionics is not responsible for devices that are improperly installed, tested or maintained. A member of the ci radionics Bosch Group Specifications Listings and Approvals • UL 864 • CSFM QriNW"C arat Oaaw 15D nA n • MEA Mmunm Bus Moaige 16 VDC r � Ordering Information Mmonvn V E*g Re sirMaroe i olms D7024 24 VDC Fie Alarm r (w/vaaion 2.0 or greater fimrware iataled) D7039 Mr*As Pail Enpersion Module D7042 Mutiplax Epl*4ngt Remote Module D7024 ControUCommunicator Board ff I/O module Standoffs and alternate r_ mounting holes for the I/O module D7039 Multiplex Expansion Module D7039 Location In 07024 Enclosure raoswzØ CERrtICATE N0.A513? ®2001 Radronics,a division of Detection Systems,Inc. 45147C 8101 PO Box 80012,Salinas,CA 93912-0012 USA Specifications D7039 Customer Service:(800)538-5807 Page 2 oft D7033 Addressable Fire System Controller Specifications Features • Addressable Fire System Controller • Compatible with the 07024 Fire Alarm Control/ Communicator • Two-line, 32-character, alphanumeric LCD display • Status LEDs identify Alarm, Trouble, Power and Sid conditions • Address setting by jumper • Permits remote control of system,inducing commands and programming 40 • Passcode protection controls system access x•; :r rg • Low profile design Description The Radionics 07033 Fire System Controller co nbines fire system annunciator and controller functions. it operates D7033Addressable Fire System Controller identically to the built-in user interface on the 07024 Fire Alarm Control/Communicator. Up to four 07033 controllers may be Application connected to a 07024. The 07033 Fire System Controller combines remote Placing jumpers on the address pins sets the controller address. annunciator and controller functions for fire alarm systems The 07033 allows remote initiation of local system tests,system controlled by the D7024 Fire Alarm Control/Communicator. programming and system control,as well as remote viewing of Access to control functions is passcode protected, allowing the system's event log. Access to system functions can be installation in areas open to the general public. passcode protected. The two-line, 32-character LCD display annunciates system status and events.The top line provides general system status Installation information,while the bottom line identifies specific devices or The D7033 is a low profile unit that maybe surface-mounted or procedures. internal sounder signals alarm and trouble mounted to a single gang,double gang,or 4 inch square back Anconditions,and box annunciates keystrokes during programming and control procedures. The control panel connection to the controller is through four wires terminating at the controller's terminal strip.Two wires are reserved Four status LEDs indicate power,alarm, trouble and silenced p -t unicalion;the othertwowires are used conditions, to supply 12 VDC power. A pullout slide with operating instructions fits behind the Refer to the control panel's installation guide for detailed wiring mounting base. length information. Install,test,and maintain this device according to its Installation Guide, NFPA 72, Local Codes and the Authority Having Jurisdiction. Failure to follow these procedures may result in failure of the device to operate properly. Radionics is not responsible for devices that are improperly installed,tested or maintained. A member of the Li ] radionics Bosch Group Specifications Listings and Approvals UL864 • CSFM Nominal Supply Volta 12 VDC ,W mA Ordering Information Standby C""ef1t (use 75 mA for battery calculations) Alarm Current 100 mA (use 75 mA ter barery calculations) 07014 Class A Zone Adapter Operating Temperature +32•F to+122•F(.0C to+50•C) D7015 Class A NAC Adapter Relative Humidity 5 b 85%RI-Non Condensing(Q 86•F) D7024 24 VDC Fie Alarm width s3 in.(18A an) Cont oUComrnunicator Height 4A in.(12.0 cm) 07030 EI t Point LED Annunciator Depth 12 in.(3.0 cm} D7033 Addressable Fire System Controller 07034 Four Paint Expander Wire Gauge #18 AWG(1.2 nm) D7035 Octal Relay Module Wire Type non-s Mde&4-type 07038 Remote NAC Power Supply Max.#of keypads/system4 07039 Multiplex Expansion Module Max.distance between 2,0002(610 m) 07042 Multiplex Eight Input Remote Module control&keypad Max.distance of keypad 4,0001t.(1,219 m) widngiws Address Jumper (Address 1) © v III 24t .. 0 Address Pins m e e® Terminal Strip ®p o � O ri Internal Sounder leottttri csmWICATS se Mis? m 2001 Radionics,a division of Detection Systems,Inc. 36256E 8/01 PO Box 80012,Salinas,CA 93912-0012 USA Specifications D7033 Customer Service:(800)538-5807 L887 Page 2 of 2 D7044, D7044M, D7052 Multiplex Input Modules Specifications Features • D7044M Single Input Contact,Class B- Fits into a Single Gang Box • D7044 Single Input Contact,Class B-Fits into a standard Double Gang or 4x4 Box • D7052 Dual Input Contact,Class A or B- Fits into a standard Double Gang or 4x4 Box donics • Easy Addressing via Rotary Switches • Low Current Draw • Use with D7024 Series Fire Alarm Control Panels with a multiplex bus • U L Listed Description The D7044,D7044M and D7052 Multiplex Input Modules Installation are general purpose devices that connect a WO contact device to the multiplex bus of the control panel with a Connections are made using the terminals on the rear supervised input loop.All operating power for the input of the and including o D7 #12 All terminals can accommodate modules is drawn from the control panel. up to AWG(2.3 mm)wire,however, make sure to follow wiring guidelines as specified by Rotary switches provide for convenient address setting. NFPA-70 (the National Electrical Code). All wiring is An on-board status LED on the Multiplex Input Modules power limited and supervised. indicates Normal,Alarm and Trouble conditions and is Connections for the D7044M are made using the flying visible on the module or via an aesthetically pleasing, leads from the device. low profile faceplate. Install, test and maintain this device according to the Application Installation Guide, NFPA 72, Local Codes and the Authority Having Jurisdiction. Failure to follow these The D7044,D7044M and D7052 Multiplex Input Modules procedures may result in failure of the device to operate are used whenever it in necessary to connect a Normally properly. Radionics is not responsible for devices that Open (N/O) contact to the Multiplex Bus of a D7024. are improperly installed,tested and maintained. The D7044 and D7044M may be used in a Class B configuration with a Supervised input. The D7052 is suitable for 2 Class B Supervised inputs or 1 Class A input. A member of the radionics Bosch Group Specifications POWER REQUIREMENTS 122VVDC nominal,550pA Alarm and Standby.Power supplied from the Multiplex INPUTS 07044M and 07044 accept a single Normally Open(N.O.)input contact. SSupervised by a 2.21 It EOL. D7052 accepts Iwo Normally Open(N.O.) contacts in Class B operation. Each input is supervMsed by a 2.21 k EOL The 07052 viii also accept 1 Input In Class A operation.No EOL is required in Class A operation. ALARM OUTPUT Reports Alarm and Point Number to the FACP. TROUBLE OUTPUT Reports Trouble and Potts Number to the FACP. RADIO FREQUENCY INTERF£RE14CE No alarm on critical frequencies in the range from 26 to 950 Megahertz (RA)IMMUNITY at 30 yam_ STORAGE&OPERATING +32°to+120°F/0°to+49°C.non-condensing RH. TEMPERATURE TEST FEATURES Internal LED Indicates the modtie status:Flashes every 4 seconds for an Alarm oondMon,(ashes every 8 seconds to indicate normal operation and flashes every 16 seconds to indicate a Trouble condition. ADDRESS PROGRAMMING Addresses are set by 3 rotary switches. ENCLOSURE DESIGN ABS plastic enclosure. D7044M Measures:i W16 in.H.,by 23!4 in.W.,by 11/16 in.D.(4 cm H.,7 cm W.,1.75 cm D).Weighs 2.9 oz.(82 9). 07044 and D7052 Meas re 4 5/16 in.H. by 4 5116 in.W.,by 1 1/16 in.D.(10.9 cm H.,10.9 c m W.,2.7 cm D).Weighs 3.e oz.(110 g). WIRING D7044M has 16 AWG(1.5 mm)flying leads. D7044 and 07052 ternnine!blocks accept up to 12 AWG(2.3 mm)wire. MOUNTING D7044M will It into a single gang or larger electrical box. 07044 and D7052 mount onto a double gang or a 4 in.square electrical box. LISTINGS UL Listing UL864 II '- 8 ovM� � ovum. ti S D7044 D7044M D7052 moseesQ C l7IRCAlEwa.A$127 ®2002 Radionics,a division of Detection Systems, Inc. 50889B 5/02 PO Box 80012,Salinas,CA 93912-0012 USA Specifications D7044, D7044M, D7052 Customer Service: (800) 538-5807 Page 2 of 2 D7045 Multiplex Fire Alarm Pull Station Specifications Features • D7045 Single Action Pull Station • Use with 07024 Series Fire Alarm Control Panels with D7039 Multiplex Bus Module • Easy Addressing via Rotary Switches 1 • Low Current Draw • Keylock Reset • Replaceable Glass Breakrod Option • Terminal Connections • ADA Compliant • UL Listed 07045 Manual Fire Alarm Pull Station Description Application The D7045 Manual Fire Alarm Pull Station is an accessory The Radionics' D7045 Multiplex Fire Alarm Pull Station,is a device for the Radionics D7024 FACP used in fire alarm single action,UL listed fire alarm initiating device.The D7045 applications. Fire alarm boxes are generally installed near has an easily identifiable pull down lever and contains an building fire exits such as lobbies or stairways. Persons integral break glass rod carrier, evacuating the building during an emergency are able to The D7045 is compatible with the following accessory initiate an alarm by pulling down a lever.This alerts others devices: who may still be inside.Schools,factories,offices,and health • D463 Double Action Lift Kit care facilities are typical applications. • D464 Red, Deep Back Box The snap lock feature of the 07045 prevents the unit from being reset without a key so the origin of the alarm can be • 0465 Glass Break Tubes more easily determined. The unit is a high quality manual fire alarm box constructed Installation entirely of non-toxic materials with a low profile and rounded edges to fit most design applications. All components are The Radionics' D7045 Manual Fire Alarm Pull Station is a prepainted or have plated surfaces to inhibit corrosion.Non- UL listed fire alarm initiating device.The D7045 is installed corroding screw terminals are provided for wire connections alone or with other approved mechanical devices on to the 07045. Radionics 07024 FACP.Fire alarm boxes must be installed The 07045 is manufactured in conformance with the according to codes set by the authority having jurisdiction. standards set forth in the Americans with Disabilities Act. The D7045 mounts to a standard flush or surface mounted The 07045 has a white pull down lever in its center.Pulling single gang switch box or plaster ring. Slotted screw holes down the lever latches it into place. The D7045's normally allow for correct positioning during installation. open contact switch is shorted causing an alarm on the fire Two corrosion resistant screw terminals are provided for wire initiating loop. The pull down lever can not be reset unless connections. All wiring and installation is subject to the the correct key is inserted into the manual fire alarm box authority having jurisdiction. lock and the unit is opened.The latching lever can then be restored to its normal position. Install, test and maintain this device according to the When the D7045 is being reset and has a glass break rod Installation Guide,NFPA 72,Local Codes and the Authority Having Jurisdiction. Failure to follow these procedures may installed,all debris must be removed prior to installing another result in failure of the device to operate properly. Radionics rod to ensure the unit will dose and lock securely. is not responsible for devices that are improperly installed, tested and maintained. A member of the cii radionics Bosch Group Specifications POWER REQUIREMENTS 12 VDC nominal,550pA Alarm and Standby.Power supplied from the Multiplex bus. INPUTS Single Action. ALARM OUTPUT Reports Alarm and Point Number to the FACP. TROUBLE OUTPUT Reports Trouble and Point Number to the FACP. RADIO FREQUENCY INTERFERENCE No alarm on critical frequencies in the range from 2610 950 Megahertz (RFI)IMMUNITY at 30 v/m. STORAGE&OE RATING +32°to+120°F 10°to+49°C.non-condensing RH. ADDRESS PROGRAMMING Addresses are set by 3 rotary switches. ENCLOSURE DESIGN Diecasi Zinc Alloy and steel enclosure. D7045 Measures:4.75 in.H.,by 3.75 In.W.,by 3.25 in.D.(12 cm H.,9.5 cm W., 8.2 cm D).Weighs I L.8 oz.(680 g). WIRING Terminal block accepts up to 12 AWG(2.3 mm)wire. MOUNTING The D7045mounts to a 3 in.x 2 in.x 314 device box(like a Steel City CXW)or a 4 in.x 21/8 square box wish a 518 in.mud ring(Il ke the Steel City 5 171 box and 52-C-14-5/8 mud ring)wilt the two provided screws. OPTIONS O463 Double Action Cover. D464 Red Back Box for manual Pull Stations,Deep. D465 Replacement Glass Break Rod. LISTINGS UL Listing UL864 ORDERING INFORMATION D7045 Single Action Pull Station IrT D7045 Rear View rso lm CERnRCA7E NO.A5137 ®2002 Radionics,a division of Detection Systems, Inc. 50891 B 5102 PO Box 80012, Salinas,CA 93912-0012 USA Specifications D7045 Customer Service:(800) 538-5807 Page 2 of 2 D7050 Series Multiplex Photoelectric Smoke Detectors Specifications Features • Cones to a two-wire Flex sus • Superior Dust Immunity • Exclusive Chamber Check Sell Diagnostics • Automatic Sensitivity Test Features • 135•F(57•C)Heat Sensor(D7050TH) • Easy 0isassenthly forCleaning • 07050 and D7050TH Require a D7050`88 Base • D705ODH Requires a D343 Duct Smoke Detector Housing • UL, ULC,CSFM Listed Description The D7050 and D7050TH are low profile, Multiplexing, D7050 Series Smoke Detectors Photoelectric System type smoke detectors for the 07024 Installation Series Fire Alarm Control/Communicators using a D7039 Multiplex Expansion Module. The D7050DH is designed for Radio. cs smoke and heat detectors are compound devices. use with the 0343 Dud Smoke Deleclor Housing.The paierNed The deleclor base installs over a back box and contains all the chamber design provides superior immunity to false alaiTns yam.The dettedor head attaches to the base by aligning the caused by dust. The detector is designed for use with head with the base and turning it clockwise. No tools are commercial and household fire warning systems. An LED aed for insabio n other than the hex key used to tighten indicator flashes to verify>hct the detector has power and the fine tamper stew. smoke sampling cattrilry is fincfioring. maintain these When properly installed using the D7050-86 base or the D343 devices according to their Smoke Detector Housing, tamper protection is provided by uicu ' NFPA e t Local Codes and these procedures d Authority multiplex wiring. This causes the combat panel to miflate a tlavang'Icrrisdiction failure to follow may trouble signal when a detector is removed from its base. resat in thicure of acre device b operate properly. Rad s is to not resporuslole for devioes drat are improperly installed,tested and maintained. Application The D7050 Series smoke detectors are intended for detection D7050-B6 Multiplex Smoke Detector circuits installed in areas where personnel are present Heat Base detectors are appropriate for circuits that supervise property. The D7050 Series Photoelectric Smoke Detectors are to detect large smoke the D7050 and D7050TH Multiplex Photoelectric Smoke The D7050TH which has an added fixed temperature sensor, gang his odagoeasy-t instil base can be nttac attached to single gang or 3.5 in.octagonal box,surface mounted, or mounted expands the detector application to confined areas where a b a 4 in.square electrical gang box using the supplied adaptor fire increases air temperature slowly and where there is a to substantial increase in air tsmpemtuse before the fee breaks confinement, such as furnace rooms, closets, and other confined areas. Features The D70500H Photoeleckic Smoke Detector is designed to detect smoke particles in air ducts when used with the 0343 • yto insIst Duct Smoke Detector Housing. • Compact tow proms design • Stainless steel contacts rjJA member of the radionics Bosch Group Specifications Listings and Approvals • UL(UL864),ULC, CSFM Listed • X,St Fiats*A o 85 to 12 vi era Ordering Information Standby SM pA Nominal Current Alarm Current 550 pA Max. Operating +32-F to 100F(0'C to 36'C) 07080 Multiplex Photoelectric Smoke Detector Temperatuiee D70ti0TH Multiplex Photoelectric Smoke Detector with Heat Sensor 07050TH +135'F(57'C)high temperature.re. 135•F(57'C)Heat Sensor Chamber The Chamber Checc automalc sensileriyr Net D7060DH Multiplex Photoelectric Smoke Detector for use Check Self feature provides an iron(the detector is with the 0343 Duct Smoke Detector Housing Diagnostics outside the factory c lbmW apseie.th nor. 07060.86 Multiplex Base This feature reduces service coals because the DRA-12124 Remote Alarm Annunciator installer can easily determine vMukh detectors require attention.This feature aiso induces DT-1 Removal Tool false alarms by Muting the and user that lie SMK-TM Test Magnet detector is lily,long baton the pond y of producing a false sham A unique Chamber Check signal is provided. Patented The detection chamber includes computer Chamber designed chamber ask and lenses to optimize Design internal light scattering and dust hiding capabilities.This provides for industry leading dust irrrsrnlyr without sacrificing detection.The detection chamber can be easily removed should it require cleaning. Radio No alarm or setup on critical frequencies in the Frequency range 01 26 to 950 Megahertz at 50 vim. interference (RFI)Immunity Tout Features LED automatically flashes to indicate calibration trouble condition.A steady LED indicates an alarm condition.Sensitivity can be verified bye nognet lest. Power-up Time 22 seconds maximum Enclosure High impact,lire retardant ABS plastic Dimension enclosure.4 in.(102 cn Diameter 1.3 in.(3.3 cm) Height ISO 9002 CERTIRCATE NO.A5137 ®2002 Radionics, a division of Detection Systems, Inc. 48817C 11102 PO Box 80012,Salinas,CA 93912-0012 USA Specification Sheet D7050 Series Customer Service: (888)538-5807 L1149 Page 2 of 2 WheBlock,NC. • • - - Helping People Take Actions"" -•• • Description: Series AS Audible Strobe £r Series AH Audible Appliances are ideal for 2 wire applications with 3 selectable dBA settings(90,95, 99)End wall or ceiling mounting. Strobe Options: Single Candela Wall: 1575 cd Multi Candela Field Selectable Wall: 15/30/75/110 cd or 135/185 cd Ceiling: 15/30/75/95 cd or 115/177 cd Features: • Selectable Continuous Horn or Temporal(Code 3) • 3 Selectable dBA settings of 90,95 and 99 dBA in both tones • Patented Universal Mounting Plate Series AH • Wall and ceiling mount Series AS • Synchronize strobe and audible with Wheelock SM,DSM Sync Modules or PS-1 2/24-8CP and PS-1 2/24-8MP Power Supplies with built-in sync protocol Specification and Ordering Information Model Model Agency Approvals Model Number Order Strobe 24 12 Wall Ceiling 9 Y PP ovals Code Candela VDC VDC Mount Mount Color Color Mounting Options# Red White UL MEA CSFM FM BFP AS-24MCW-FW 9025 15/30175/110 X - X - - X B,D,E,F,GH,J,N,O,R,X X X X X X AS-24MCWH-FW 3469 135/185 X - X - - X B,D,E,F,GH,J,N,O,R,X X * X * AS-121575W-FR 7410 15(75 on Aps) - X X X B,D,E,F,GH,J,N,O,R,X X X X X it AS-24MCC-FW 3162 15/30!75/95 X - - X - X B,D,E,F,GH,J,N,O,R,X X X X * * it ASWP-2475W-FR 9012 180@77F x - x - X I(Outdoor) X X X X X 75 @-31F AH-24-W 7893 - X - X X - X B,D,E,F,GH,J,N,O,R,X X X X X X AH-12-W 7894 - - X X X - X B,D,E,F,GH,J,N,O,R,X X X X X X AH-12WP-R 7415 - - X X X X - K(Outdoor) X X X * X #See mounting options pull out guide in the last section of this binder. X=Approved *=Pending Average RMS Current Audible Wall Mount Audible Strobe Models Ceiling Mount Strobe Models 24 VDC Models AH-24 AS-241575W AS-24MCW AS-24MCWH AS-24MCC AS-24MCCH 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 24 vdc 0.062 0.100 0.080 0.102 0.150 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 High(99)dBA UL max* 0.080 0.121 0.088 0.125 0.200 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 24 vdc 0.033 0.080 0.060 0.084 0.132 0.173 0.230 0.305 0.066 0.092 0.145 0.186 0.230 0.305 Med(95)dBA UL max* 0.043 0.107 0.074 0.110 0.190 0.253 0.340 0.465 0.080 0.122 0.201 0.269 0.340 0.465 24 vdc 0.017 0.072 0.052 0.076 0.121 0.158 0.220 0.295 0.056 0.082 0.132 0.173 0.220 0.295 Low(90)dBA UL max* 0.021 0.100 0.068 0.105 0.182 0.245 0.335 0.460 0.074 0.113 0.198 0.263 0.335 0.460 Audible Wall Mount Audible AH-12 Strobe AS-121575W per average are g*RMS current ratingsUL RMS method. UL max current 12 vDC Models rating is the maximum RMS current within the listed voltage range (16- High(99) Low High(99) Med Low 33v for 24v units). For strobes the UL max current is usually at the dBA Med(95)dBA (90) dBA (95) (90) minimum listed voltage(16v for 24v units). For audibles the max current DBA I dBA DBA is usually at the maximum listed voltage(33v for 24v units). For unfiltered 12 vdc 0.163 0.076 0.039 0.260 0.195 0.175 FWR ratings, see installation instructions. UL max* 0.192 0.108 0.058 0.320 0.275 0.265 08/04 wheelock INC. • • Helping People Take Actions"" • • • Description: ' • • Wheelock Series RSS Strobes provide a wide range ofintensities and mounting options for wall or ceiling applications. Series RSSP Single&Multi-Candela Strobe Plates are designed for retrofitting existing audible notification appliances to strobe applications. Strobe Options: Single Candela: 1575 cd (wall), 75 cd (weatherproofl Multi Candela Field Selectable Wall: 1 5/30/75/11 0 cd or 135/185 cd Ceiling: 15/30/75/95 cd or 11 5/1 77 cd Features: Series RSS • Patented Universal Mounting Plate • Low current draw to reduce power consumption and wiring costs • Strobes produce 1 flash per second over the regulated voltage range Series RSSP • Synchronize with Wheelock's SM,DSM Sync Modules or PS-1 2/24-8CP and PS-1 2/24-8MP Power Supplies with built-in sync protocol Specification and Ordering Information Order Model y vals Model Number Code Mount Mount Candela VDC VDC ReColor C Strobe 24 12 olor Mounting Options# square or UL MEAcCSFMoFM BFP RSS-24MCW-FW 9401 X - 15/30175/110 X - - X B,D,E,F,CxH,J,N,O,P,R,X Square X X X X X RSS-241575W-FW 7788 X - 15(75 on Ads) X - - X B,D,E,F,G,H,J,N,O,P,R) Square X X X X X RSS-121575W-FW 7468 X - 15(75 on Axis) - X - X B,D,E,F,CAH,J,N,O,P,R,X Square X X X X X RSS-24MCCR-FW 3159 - X 15/30/75/95 x - - x B,D,E,F,G,H,J,N,O,P,R,X Round X X X X RSS-24MCCHR-FW 3463 - x 115/177 X - - X B,D,E,F,G,H,J,N,O,P,R,X Round X X X * * RSSWP-2475W-FR 9013 X - 180@77F x - X - B,D,E,F,GH,J,N,O,P,R,X Square X X X X * 75@-31T RSSP-121575W-FR 7798 X - 15(75 on Axis) - X X - E,Z Square X X X X X RSSP-241575W-FR 7793 X - 15(75 on Axis) - - X - E,Z Square X X X X X #See mounting options pull out guide in the last section of this binder. Average RMS Current X =Approved *=Pending RSSIRSSP RSS/RSSP-Wall Mount RSS-Ceiling Mount 24VDC 241575W 24MCW 24MCWH 24MCC 24MCCH Models 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 24 vdc 0.060 0.041 0.063 0.109 0.140 0.195 0.270 0.045 0.070 0.119 0.159 0.195 0.270 UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 RSSIRSSP RSSIRSSP *RMS current ratings are per UL average RMS method. UL max current rating is the maximum 24VDC Wall Mount RMS current within the listed voltage range(16-33v for 24v units). For strobes the UL max Models 121575W current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR 12 vdc 0.152 ratings, see installation instructions. UL max* 0.255 08/04 DTK=MRJ Series Modular Station Set SURGE PROTECTION 4 II k DTK4MRJ-11 ', s � a DTK-MRJ-14 Sr DTK-MRJ-25 DTK4 0-45 "Location, location, location!" "Who cares?" With the "MRJ" series of surge protectors from DITEK, you can protect two line systems and individual equipment at the service entrance, the "Point of Use" equipment, or anywhere in between. Plus, with over one hundred variations of components, wiring and pin configurations, there are not many applications that can't be protected- From incoming "CO" lines, to stations, T1, ISDN, RS data and more, DITEK's "MRJ" series will protect them all. FEATURES BENEFITS Multiple damping voltages Meets specific applications Modular Easy integration Provides over voltage protection Voltage&amperage protection and self-resetting fusing(specify 'SCP'suffix) Self Restoring Lower maintenance ONE DFTEK CENTER 100-753.2345 *„; 1720 Starkey Road, www.ditekcorp.com Largo,FL 33771 General Specifications - MRJ Series Agency Approvals: UL497B, UL497A(specify) Connection Method: Universal RJ11/14/25/45(1-4 pair,specify) Continuous Current: 0.150 Amps('SCP') 5.0 Amps(non 'SCP') Protection Modes: T-G, R-G(all modes) Warranty: Limited Lifetime Warranty Dimension: 3.08"x 2.67"x 1.16" Weight: 0.44 lbs Housing: ABS Other Specifications D X LV OPX SPK SGR RUV Service Voltage 6V 14V 30V 50V 75V 95V 130V MCOV: BVDC I8VDC 38VDC 66VDC 102VDC 127V0 175VDC Typical clamp: 9-16 20-24 4252 74-90 108-132 135-165 184-224 Max Surge Current: 20001 2000A 2000A 2000A 9000A 9000A 9000A Joules *: 4 8 17 30 44 60 76 *Per pair F 1 16" .old" ______ M198-MRJ Rev4P2 03 DTK-1 20S1 5A Series SURGE PROTECTION The DTK-120S15A `Critical Load' surge protector from DITEK is a true multi-stage series hybrid design which provides the best filtering and lowest clamp levels in its class. Available in both 120V and 120/240V versions for circuits up to 20 Amps, it meets both government and military specs for fire panel applications. A user replaceable fuse means less down time and longer service life. FEATURES BENEFITS Series Design Fastest response time available; Tighter damp than parallel device Hybrid Protection Circuitry Four stages of protection insures maximum performance User replaceable fusing Less"post event"downtime Screw Lug Termination Speedy connect/disconnect of power wiring; Neat appearance,no wire nuts needed Low profile design Uses less space,fits wide variety of cabinet depths Multiple diagnostic indicators Monitor protection status,ground presence, ground fault and fuse status ONE DITEK CENTER 1-800-753-2345 1720 Starkey Road, www.diitekoorp.com Largo,FL 33771 General Specifications - 120S15A Agency Approvals: UL 1449,Wyle Labs Service Voltage: 110-120 VAC or 120/240 VAC MCOV: , : 130 VAC or 130/260 VAC Continuous Current: 15 or 20 Amps(Specify) Max. Surge Current: 39,000 Amps EMIIRFI Noise Filtering: >56db 100KHz- 100MHz Protection Modes: L -L,L, L- N, L-G, N -G Suppressed Voltage Rating: 330V Warranty: Limited Lifetime Warranty Diminsions: 6.00"x 3.58"x 2.32" Weight: .55 lbs. Housing: ABS 2x 0.19' I ±fl I 232 M 22F 1.9Zt. M-1981S15A Rev 3123103