HomeMy WebLinkAbout08-8155 (2) EXIST . HOUSE ROOF
Ht _____________ __
EXIST . OPEN
HOUSE PORCH - EXISTING EXISTING -
HOUSE SHED
NEW ROOM
ADDITION
15' 11 '
WALL A/C UNIT
FRONT ELEVATION O
D
HOUSE WALL AND DOOR
WILL REMAIN NEW ADDITION
NEW WALLS
WALL A/C UNIT 11'
OPEN EXISTING
PORCH SHED FRONT DOOR
NEW ADDITION 0 0
-5' 13 '
FLOOR / ELECTRICAL PLAN
SIDE ELEVATION
PcZ.�l.4�Q- 'C J1HtLi� CJ '�LVlC G'. RWANDA $AWARDS WIND ZONE
39507 MEADAWOOD LOOP 120 MPH
6440 T& t 1I 9 Zaud ZEPHYRH1LlS, FL. 33542
3phyh/i*11.1, TL. 33542 ENCLOSE CARPORT - $- R88H SHEET
oFfICF
DESIGN/DRAWN DATE
cf'uLccsut¢ [�a1+sL (813) ?88-5314 efae- �6,L 0s/04/Da 1 OF I
ENGINEER'S NOTES WINDOW &DOOR MANUFACTURERS TO PROVIDE CERTIFICATION THAT THEIR WINDOWS AND
1) THE BASIC DESIGN WIND SPEED=120 MPH, 3 SEC GUST DOORS WILL WITHSTAND THE FORCE RESULTING FROM THE SPECIFIED DESIGN C&C WIND PRESSURE.
> THE IMPORTANCE FACTOR = 0,77 AND PROVIDE INSTALLATION INFORMATION TO THE BUILDER SUCH THAT WHEN INSTALLED PER SAID INSTRUCTIONS
THE WINDOW WILL PROVIDE THE CERTIFIED PERFORMANCE.
3) THE EXPOSURE CATAGORY = B THE CONTRACTOR IS TO INSTALL THE WINDOWS AND DOORS ACCORDING TO THE SPECIFIC INSTALLATION INSTRUCTIONS
THE INTERNAL PRESSURE CDEFF.= +/-0.55 PARTIALLY OPEN SUPPLIED BY THE WINDOW AND DOOR MANUFACTURER.
BUILDER TO HAVE MANUFACTURERS SPECIFICATIONS (CUT SHEETS) ON SITE AT THE TIME OF INSPECTION
> THE COMP. & CLADDING DESIGN PRESSURES ARE PER FOR REFIEW BY THE BUILDING INSPECTOR,
TABLE R301.2(2) FBCB 2004 NOTE: WHEN ENCLOSED STRUCTURES IS BELOW BFE
IT SHALL BE CONSTRUCTED OF WATER RESISTANT MATERIALS 1/2' CDX SHEATHING NAILED W/801 R/S NAILS @ 6' O.C. ON EDGES
& WITH HYDROSTATIC OPENINGS PER SITE SPECIFIC SHEET &10' O.C. IN FIELD. USE 1/2' PLYCLIPS.
PER FEMA-TB-1-93&NFIP 60.3(c)(5) &ASCE 24-98 15# FELT AND SPECIFIED SHINGLES APPLIED
1/2' MIN. GYPSUM SEPARATION FROM LIVING AREA APPLIED TO GARAGE SIDE OF WALL PER MFGRS SPECS FOR 110MPH WIND SPEED ZONE
STRUCTURAL PANELS PER R309.2 (4) NAILS MIN PER SHINGLE.
NOTE: WOOD STRUCTURAL PANELS OF SIDE WALLS SHALL
OVERLAP THE TOP MEMBER OF THE SIMPSON HIO CLIP @ ALL
DOUBLE TOP PLATE AND THE BOTTOM PLATE. TRUSS TO DBL TOP PLATE
A ROW OF 1001 NAILS 2 3' D.C. SHALL BE 1/2' CONNECTIONS (RATED 905# UPLIFT) R25 INS
MINIMUM FROM EDGE OF BOTH TOP PLATES&BOTTOM PLATE.
USE TWO STAGGERED ROWS OF NAILS ON 3' D.C
@BOTTOM PLATE &6' @VERTICAL EDGES&12' IN FIELD PRE ENGINEERED TRUSSES @2' OC.
USE 801 NAILS @ 6' @ VERT. EDGES&12' D.C. IN FIELD 2X4 WOOD SUB FASCIA 47PSF LOADING/SHINGLES/12OMPH WIND LOAD
&ALUM DRIP' AND FASCIA ROOF PITCH PER SITE SPECIFIC PLAN
NOTE:
WHEREVER THE STRUCTURAL PANELS ARE NOT CONTINUOUS FROM
TOP MEMBER OF TOP PLATE TO BOTTOM PLATE AND
WITHIN 4FT OF EACH CORNER AND ATTACHMENTS TO EXISTING STRUCTURE
USE SIMPSON SP1 DR EQUIVALENT AT STUD TO BOTTOM PLATE CONNECTION & VINYL SOFFET MATERIALS
USE SIMPSON SP2 OR EQUIVALENT AT STUD TO DBL TOP PLATE CONNECTION
OR EQUIV. APPLIED PER MFG'RS SPECIFICATIONS INSIDE OR OUTSIDE DBL 2x4 TOP PLATE SIMPSON SP2 1/2' CEILING GYPSUM
PER NOTE FASTEN 27' O.C. MAX
CONFIRM EXISTING CLIP
@ TRUSSES TO EXISTING BEAM
1/2' GYPSUM
DBL 2x-HEADER PER
R25 INS PER FBC 2308.5 W/
(1) LAYER 1/2' ❑SB OR CDX WINDOWS PER SCHEDULE
(QQ�Qs RATED FOR 110 MPH WIND SPEED &
1/2' CEILING GYPSUM APPLIED PER MFGRS INSTRUCTIONS
N. FASTEN 27' D.C. MAX 1/2' CDX OR OSB `I)
EXISTING ROOF& TRUSS STRUCTURE STRUCTURAL SHEATHING MARBLE WINDOW SILLS
FASTEN PER NOTE
EXISTING BOXED BEAM
AT EXISTING CARPORT DR R11 INS 2x4 STUDS@16' O.C. CONSTRUCTION
COVERED PATIO STRUCTURE
SIDING AS SPECIFIED SIDING WOOD BASE TRIM
SINGLE 2x4 TOP PLATE AS SPECIFIED
1/2' CDX OR OSB
OVER TYVEC OVER WHEN ATTACHED TO EXISTING BEAM FLOOR COVERING
STRUCTURAL SHEATHING TYPICAL 2x4 STUDS@ 16' D.C. WALL CONSTRUCTION PT 2x4 BASE PLATE SIMPSON SP1 PER OWNER
FASTEN PER NOTE WITH CLIPS TO TOP&BOTTOM PLATE PER DETAIL FASTEN TO FOUNDATION W/ PER NOTE
L / -
APPLIED PER MFGRS SPECS TO EITHER OUSIDE OR INSIDE 1/2' WEDGE ANCHORS x4 1/4'
EMBEDMENT LOCATED WITHIN 8' OF CORNERS
EACH SIDE OF DOORS &WINDOWS OPENINGS ••
& 24' D.C. MAX
PT 2x4 BASE PLATE �%/\�j/\/\\\/\\//\ '•.... '• •�j�\\/�/\�j/j/\\j\\//�\\//\\///\�//\\///\
FASTEN TO FOUNDATION W/ � \\ \\j //j \/\/ / \ \ \j ////\\/\ 4" 3000 PSI CONCRETE SLAB
1/2' WEDGE ANC \ \/ / FIL
EMBEDMEDG LANCTEDW/6x6-#10/#10 WWM OR POLY
�\\-
OVER 6 MIL POLY FILM W/ EDGES
EACH SIDE OF DOORS &WINDOWS OPENINGS LAPPED 6' & TAPED OVER
& 24' D.C. MAX
HORS x4' CLEAN COMPACTED TERMITE
EXISTING 2500 PSI 4' MIN SLAB AND FDUNDATI IN /�/ / \\\�/\\ TREATED SOIL
WOOD AND NON TERMITE RESISTIVE MATERIALS 3000 PSI CONCRETE
SHALL BE 6' ABOVE GRADE C2 TYPICAL WOOD FRAME
SEE DETAIL
OR EQUIV. ON FOUNDATION SHEET I hereby certify that I have perforned and reviewed / 16Hx 12W MONOLITHIC FOOTER
this plan and found it to be in compliance with ASCE 7-02 & W/(2) #5 REBAR CONTINUOUS SECTION
the Florida building code 2004 edition and all updates. ON CHAIRS SPACED 4' MAX D.C.
and r visions through the 2006 SUPPLEMENT to FBC 04
:%\�i��\ �� #
D.W.SMITH,M.S., P.E.#53608 TYPICAL SECTION SHEET OF
\ FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 FRAME ROOM ADDITION 1 OF
WOOD FRAME WALL DETAIL FOR t' Projects Consulting Engineer
9909 WALLASTON DRIVE-DADE CITY,FLORIDA 33525 SCALE I DATE PART NO.
CONVERSION OF COVERED ADDITION `� David W, Smith,P,E, P4 M352-521-D%5 FAr:N-52l-o87 E-NAIL dWipeewthur.net DO NOT SCALE 07/14/08
FRAME WALL
TO ROOM ADDITION - � ' ENGINEER PASCO PERMIT SERVICE DESIGN/DRAWN CHECKED SECTIONS
LICENCE #53608 SUZANNE BAHR 866-824-7894 D.W.SMITH,P.E.