HomeMy WebLinkAbout08-8303 (2) o e-
ENGINEER'S NOTES: BETWEEN PURLOINS AND PANS
BOARDS
1.THE BASIC DESIGN WIND SPEED= 140 MPH, 3 SEC GUST 5�
EDGE OF EXISTING ROOF
2. THE WIND IMPORTANCE FACTOR IS 1.0
ie
3. THE WIND EXPOSURE CATAGORY ='B' - I
4. THE INTERNAL PRESSURE COEFFICIENT = +.18/-,18
TOTALLY ENCLOSED TYPE U STRUCTURE 316 D!A (3) H 'OLE 2' 1 1/2'
S. C&C DESIGN WIND PRESSURES ARE PER — 4' O. , MAX FASTEN /ALUM NIDX3LR W TEKS 1�
e 12. 0 C' MAX
FBCB 2004 TABLE R301,2(2) CORROSION RESISTIVE I
024' RIDGE CAP 2' THICK SYROFOAM INSULATION BOARDS 112'
FASTEN TO TOP OF EACH RISER V/ LIP& FASTENERS PER DETAIL EN AND 11
tICx1/2' SCREW& NEOPRENE WASHER 6CLIP ATTACHMENT PLAN BETE PURLINS PANS L-��---
LIP& FASTENERS PER DETAIL RIDGE LINE - TYPICAL �---
&CLIP ATTACHMENT PLAN
3/4' 2'x2 PURLI - 26 GA. SUNSTATE
GALVANIZED CLIP DETAIL
FASTEN TO ROOF OR ALUMINUM PURLIN
1 1/2'xl2'x.024' W/(3> N10x3/4' TEKS
ALUM ROOF PANEL
METALS USA FLM 1779.1 _
OR EQUIVALENT RATED FOR
INDICATED WIND SPEED
.Is+'w mar
TYPICAL SECTION 0 ROOF OVER ACIA OR GUTTER
OPT IGNAL
.024 RIDGE CAP LIP& FASTENERS PER DETAIL
FASTEN TO TOP OF EACH RISER V/ &CLIP ATTACHMENT PLAN ' MAX $$ E[ EE T Y P IC A L
*ICx1/2' SCREW& NEOPRENE WASHER 6CLIP AITACNHMENTPPRADETAIL I /
ALIUM,RIOOF PANEL EDGE OF EXISTING ROOF
�_ 3/4' METALS USA FL& 1779.1
OR EQUIVALENT RATED FCR
INDICATED WIND SPEED J-" S'
361 FELT MIN. OVER 15/32'MIN. STRUCTURAL PURLIN ATTACHMENT PLAN TYPICAL
WOOD PANEL ROOF PAN INSTLALLED TO
CXIST,N Ac tA OR GUTTER L FOR PANS TO PURLIN . W/INSULATING STYROFOAM EXIS TING SHINGLED ROOF OR
FlOPTIONAL TO PLYWOOD SUBSTRATE&30M FELT
TYPICAL SECTION 0 ALUM PAN ROOF OVER
30# FELT OVER STRUCTURAL WOOD PANEL SHEATHING FORMED LEADING EDGE OF PAN
CONTINUOUS CRIMPED TOGETHER
V/ DRIP EDGE USING SEAMING T00. FACIA TRIM
.032' THICK\\ ,,
_ _ VARIES 2'x2' ALUM PURLIN
N10 X 1 1/2' TEKS
_ _ _ _
° -'-4_� a 12' DC. MAX O
CORROSION RESISTIv
/ / /// �� �/�'j � / // \ EXISTING ROOF
/� ,,� /: A IES PANEL CLOSURE DETAIL
N VITN CLIPS PER PLAN
FAST NpWI HANEL , . TYPICAL BOTH ENDS
f ASTE
/ /% / / /// f/1 , YI ! rf !` ! /// ////
11 / l (,�I Itl ' ��I� I* I \
ROGF tCLt�ATSACHMENT�PLANETAR r(1'lI 11 i1�.1\. �I. I 1`11\I,.
C
-,aa ALUM PUR≤IN,i ITI � _ ,-,•
/j IES
CLIP ATTACHMENT PLAN
FOR PANS TO STRUCTURAL WOOD PA EL ROO
SHADED AREA CLIPS @ 2' DC.
SEE PANEL\SURE DETAIL CLIP ATTACHMENT DETAIL CLIPt FASTENERS CRIMPED BETWECN PANEL LIPS CENTER UNSHADED AREA: 4' D.C.
SEE PLAN SHEET#3 WITH SEAMING TOOL
PACT R\THICK - -- - D.W.SMITH M S P E #,5360 ROOF OVER SYSTEMS
SHEET Ix
2 2 ALUM PURL{N I hereby certify that I have performed and reviewed this plan and found FLIIRIDA PROFESSIONAL LICENSE ASER 53608 CNGINEEd 1 OF 1
1_EXISTTAGR0 it to be in compliance with ASCE 7-02 §ions 1609 of FBCB 2004 and p1 99C09 TO o°i EeDADEIan FSeR1oA aces UESIGN/DRAIN DATE PART O.
section R301 of FBCR 2004 edition and the 2006 Supplements to FBC 04. PO(32ulDelis IAX T2-521-C%7 - Ii�rsrlp2P°ru1; �t D.W.SMITH.P.E. 08/20/08
PASCO PERMIT SERVICE SCALE RFOVR-SS1
SUZANNE BAHR 813-788-5314 AS NOTED 13O