Loading...
HomeMy WebLinkAbout08-8632 (2) FLOOR PLAN EXIST . PARK MODEL 13 X 37 ' -6" 7 ' ---------------- ADD 2 ' X 44 ' -6" SLAB TO EXISTING ------------------------------------- -------------------------------------------------------------- ------------------------------------------------------------------------- SHED SUN ROOM WOOD FRAME CARPORT OVERHANG 3"X3"X . 093 POSTS 2X3 POSTS & BEAM 3068 2X6 SMB a --5'--I-----5' - ---4 '-- ----� ' -�-4 '--�- '- 9'-3 U 49,-3„ I I I --- 10' 16' 18 '-6" ��4 '- 3"X . 030 COMPOSITE PANEL ROOF FL 2291 VINYL SIDING 2X6 SMB z 2X3 KNEE BRACE II 3"X3"X . 093 3 '-0" 63" H POSTS L WINDOWS N z 4 " KICKPLATE / VINYL SIDING 10' NEW SLAB 10 ' 16' '- EXIST . SLA$ SIDE ELEVATION CODE. \TIC\. S 7'rx&e-o' PV L.�'y l V C'fLIrLCg 3912�DUAKER RIDGE DR. u I ND ZONE ZEPHYRHILLS, FL. 33540 110 MPH 621210 Ti Ifutg ZQad MAJESTIC OAKS 3rNtytclt[LL3., 971. 335112 SUN ROOM , D, CARPORT, SHEET AND CONCRETE SHE SLAB cS'ttzastit� LTafeL (813) 788-53111 DESIGN/DRAWN DATE �'ric V�ti 12/04/08 1 OF 1 ENGINEER'S NOTES: - 2 1/2' X 1 1/2' RECEIVING CHANNEL ADD OPEN BACK BASIC WIND VELOCITY: 125 MPH THRU BDLTED TO POST WITH 3' COMPOSITE PANEL ROOF IMPORTANCE FACTOR: 1.0 5/16-18 BOLTS FOR SIDE BEAM STRUCTAL OR ELITE OR EQUIV. INSIDE 2� CORROSION RESISTANT BOLTS, FASTEN PER MFG'RS SPECS. EXPOSURE CATAGORY: B #10x3/4' CORROSION RESISTENT MAXWASHERS, NUTS- TYPICAL W/#14x4 1/2' SEAL HD FENDER WASHER SCRWS INTERNAL PRESSURE COEFFICIENT=+,18/-.18 WASHER HEADED SCREWS D.C. DESIGN WIND PRESSURE ARE PER TABLE 1609.63 TYP BOTH SIDES #10x3' ROOF: +11/-28 PSF ZONE 13 INTO SIDE SMB 26' D.C. 2 8' O.C. M ' LJ WALLS: +27/-29 PSF ZONE 4B ' STRENGTHENED ° " " " ALUM COLUMN DETAIL ° � ALTERNATIVE TO 2x3 STUDS DETAIL OF FASTEN RECEIVING CHANNEL TO HOST 2x4 MIN FACIA SIDEBEAM �/ FASTEN 2x3 EDGE BEAM WITH 1110x2' LAG SCREWS@ 12' D.C. MAX CONNECTION 2'113'X.045' 2'113'X.045 TO COLUMN ALUM FLASHING W/(2) #1x3/4' TECHS Ctl1R£ (2) ROWS STAGGERED W/ CAPRI CLIIPS W/ INSTALLED UNDER DRIP EDGE OR 6' ALUM COLUMN ROOf #8 X 1/2' CORROSION RESISTA UNDER FIRST ROW OF SHINGLES CONNECTION DETAIL OF T STRU 1FOR ALUM UFLASSH FLASHING ALL PURPOSE SCREW POST TO 2"x3" BEAM SEALNWITH CAULK COATING NOS SEAL WITH CAULK NOTE: FOR ENCLOSED WALLS MAY USE REC. ALUM FLASHING H COMPOSITE TRUCZUR6 ROOF 3' COMPOSITE PANELS SECURED IN FOR HANNEL 0 ROOF PANELS2x3 COLUMNS S NOSE S W/#10x3/4'CHANNELS S 2A18A D.C. MAX PANELS MEMBERS PANELS 118 X 1/A` CORROSION UE SCREVTANT OFFET MAT'LS PROVIDE 1/8' DIA VEEP HOLES AT OUTSIDE BOTTOM OF REC. CHANNELS COMPOSITE OR ENCLOSE 2' R10010 FOAM INS. V/ .024 ALUM MOBILE HOME SKIN OR ROOF PANELS S DRYWALL AT INSIDE WALL & I/2' CDX FASTENED V/ 110 TEKS a 12' O.C. #1/4' 112 1/2' #14x3/4' TEKS -- ------------ ------------ COVER V6 IN SIDING OVER TYVEK OR EOUiV. VAPOR BARRIER TAPCONS (3)/SIDE a T 1x3 OPEN BACK U EDGE OF PANEL FINISHED W/ U C RECEIVEING CHANNEL FASTEN W/ 1110x3/4' TEKS 8'O.C. I T a I- _� �� U REC. I? ' • '.ii• i IF• R 3x2 x.045' 1X3 OPEN BACK CHANNEL 1�, i� ' , ��' FASTEN RECEIVING CHANNEL TO HOST 2x4 MIN FACIA : E FASTEN FASTEN FOR COMP. ./ •''. L WITH 1110x2' LAG SCREWS@ 12. O.C. MAX PAN W/ 1110x3 1/2' TEKS ELS •,- (2) ROWS STAGGERED W/ 1110x3 1/2' TEKS p M �I 12• D.C. a 12' D.C. _ •, • .. CAULK BEFORE FASTENING • TYPrCAL-CONN-ECTION 'DETAIL BASE RAIL TO DECK AND TO COLUMNS' CONNECTION TO EXISTING HOME 0' WIDE MAX WINDOW SIZE WINDOWS RATED FOR 125 MPH PER DETAIL /60' ITH 2x2 COLUMNS PTIOTE WINDOW MFGR TO PROVIDE 2'x3' ALUM COLUMN TYP (TYPICAL) INSTALLATION INSTRUCTIONS WIDE MAX WINDOW SIZE &WINDOWS TO BE INSTALLED PER 3' COMPOSITE PANEL ROOF #8 X 5/8' SMS W/WASHER ITH 2X3 OR STRENGTHENED COLUMNS 'FGR'S INSTRUCTIONS STRUCTAL OR ELITE OR EQUIV, CORROSION RESISTANT ER DETAIL ABOVE (TYPICAL) FASTEN PER MFG'RS SPECS. 3'112'X,045' 6r- / u 2'x2'STENXWITH 2x2'M BLOCKING CRI CLIPS +23 PSF +23 PSF +23 PSF -23 PSF a'23 PSF +23 PSF 2x3 ALUM POSTS @ 16' D.C, -25PSF -25PSF -25PSF -25PSF -25PSF -2VSF 6'X6' ' I VINYL SIDING OVER x �. 15/32' CDX OR OSB I / SLIDING ASS DOO U STRUCTURAL �I / �� 30' REF COLUMN 2 CORNERS +23/-2 PSF SHEATHING FASTEN W/ �III Ii I 1 OR#10x3/4' S.M.S 86' D.C. II IIii ii II Il ALUM COMPOSITE PANELS �I II /� I - IN RELIEVING CHANNELS Ii O ----------------------------------------- SWALE AS NECESSARY FRONT ELEVATION 3000 PSI CON(. -VARIOUS LENGTHS -- 12'W X 16' D FOOTER FASTEN UP TO 36' W/ (1) #5 REBAR CONTINUOUS. NOTE: 3000 PSI CONCRETE SLAB 4' THICK W/ 2x2x.045' ALUM I6' MAX 6x6/10-10 WWM OR FIBER FILL TYPICAL W/5/8'x3/4' SMS SIDE ELEVATION AY SUBSTITUTE OVER 6 MIL VAPOR FILM W/ EDGES LAPPED 6' & TAPED 3'x6'-8' PH DOOR W/ 3x2 ALUM HEADER +24/-27 PSF I hereby certify that I have performed o9eviewed this pLde, n 4 and it to be in compliance with ASCE 7-02& section R301 tithe rida Building E6de, ition D.W.SMITH,M.S.,P.E.#53608 SHEET or and the 2006 SUPPLEMENT to FBC 04. RJtIDA PR CD 0 ESSI0NAL GIICCR LICZNSC RER 536A SUN ROOM l� Custom Home Plan Service ADDITION 1 OF 1 99O9 WALLASTON DRIVE-SAXCITY.FLORIDA 33323 SCALE DATE PART NO. ?j.Q AOC'352-21-De55 r 32'52i-C, C wilt:d.srtaeeeo•thI,knt DO NOT SCALE 04/22/08 David W. Smi'th,P.E.#53608PASCO PERMIT SERVICE I DESIGN/DRAWN I CHECKEDI GLAS 08 SUZANNE BAHR 866-824-7894 D.W.SMITH,P.E. 125 ENGINEER'S NOTES: 3'x4'x 032' COMPOSITE PANEL ROOF FASTEN W/ #14x4 1/2' I,THE BASIC DESIGN WIND SPEEDS 125 MPH, 3 SEC GUST @ 8' OC. ATENDS AND RAKES DR ALUM FLASHING 2, THE WIND IMPORTANCE FACTOR IS 0.77 FOR 12'x3' x.032' ALUM PAN ROOF FASTEN W INSTALLED 6' MIN UNDER 3. THE WIND EXPOSURE CATAGORY USED IS 'B' FASTEN W/ (3) #10x3/4' WASHER/ FIRST ROW OF SHINGLES 4. THE INTERNAL PRESSURE COEFFICIENT FOR OPEN BUILDINGS IS 0.0 SEAL HD TECH SCREWS@ BOTH ENDS DR UNDER DRIP EDGE 5. C&C DESIGN WIND PRESSURE, ROOF =+18/-27 PSF VALENCE CAP #8x1/2' CORROSION RESISTANT HOST STRUCTURE ROOF WASHER HEADED SCREWS 12" APPR0X ---- ALUM FLASHING ///INSTALLED 6' MIN UNDER #8 X 1/2' CORROSION RESISTANT FIRST ROW OF SHINGLES 1/2 ALL PURPOSE SCREW �I MIN-- DR UNDER DRIP EDGE7 FASTEN 3',12'x032' ALUM PAN ROOF PANELS 1• 3105-H28 ALUM. TENSILE=28KSI/YIELD=24KSI _ BOTH ENDS W/ #10x3/4' TEKS \ 3/B-16 HEX HD BOLT, WASHERS &NUT (3) SCREWS PER PANEL EQ. SPACED \ CORROSION RESISTANT C2) CORROSION RESISTANT EXISTING 2',_'x044' 3'X3 1/8'x10' BREAK FORM CHANNEL Gj ROOF ALUM. TILT BEAM ATTACHED TO HOST STRUCTURE W/ #10X3' SMS CORROSION RESISTANT MA; @16' D.C. TO HOST STUDS STRIP SEALANT BETWEEN FACIA&HEADER FASTEN RECEIVING CHANNEL II TO HOST 2x4 MIN FACIA W/ 4X VIEW C #10x2' SMS OR LAG SCREWS SPAN=13' MAX FOR 3'xI2'x.032' ALUM PANS @ 12' D.C. MAX (2) ROWS STAGGERED SPAN =17'-3' FOR 'RHINO' GALV. STEEL PAN (3'X12'X26 GA. RISER PANELS) L� NOTE: CDNTRACTER TO VERIFY FACIA ATTACHMENT DETAIL CONDITION OF HOST STRUCTURE SPAN FOR 3'X.024' #1 DENSITY COMPOSITE PANELS =16'-6' MAX SPAN FOR 3'X.030' #1 DENSITY COMPOSITE PANELS =19'-6' MAX v X 1/2-13 HEX HD BOLT, WASHERS &NUT CORROSION RESISTANT (2) X 3',3'x,063' TO 8'-6' MAX 11 GA INTERNAL ALUM BASE g 3',3'x.093' TO 10'-6' MAX N PREDRILL VERT FLANGES (6) 1/4' rAPCONs/WASHERS&NUTS 2' MIN CD ALUMINUM COLUMNS @8' DC. MAX WITH 2x4 EDGE BEAM (2) 1/2' THRU BOLTS IMBEDMENT. CORROSION RESISTANT ALUMINUM COLUMNS @10' D.C. MAX WITH 2x6 EDGE BEAM TYPICAL - - I 3/8-16 HEX HD BOLT, WASHERS &NUT 3/8-16 HEX HD BOLT, WASHERS UT CORROSION RESISTANT (2) " '• -:'-"=r *- =: - CORROSION RESISTANT (2> 4' CONCRETE SLAB OR FOOTING 11 GA INTERNAL ALUMINUM BASE WITH 6X6 10/10 WWM OVER DETAIL OF O PREDRILL VERT FLANGES 6 MIL POLY FILM OVERLAPPED 6' END POST TO CONCRETE (2) 3/8' THRU BOLTS TH OVER CLEAN COMPACTED SOIL CONNECTION WITH EDGES TAPED 2',4'x.063' COLUMN' 5 FASTENED EXPANSION BOLT- -- - - -- - ALUM TILT BEAM 2 1/2' MIN. ENGAGEMENT WITH SLAB 3'x3'x,063' ALUMINUM COLUMNS @B' O.C. MAX TYPICAL (3) IN FRONT@ 8' O.C. GRADE ENLARGED VIEW I NOTE NO FOOTER REQ'D EXCEPT WHEN ADDRESSING ERROSION T COLUMN TO SIB 4' 2500 PSI NOMINAL SLAB W/D FOOTER MAY __ BE USED ON LEVEL GROUND UP TO SLOPES OF 1'/12' H&W=6'x8' FOR GRADE SLOPE GREATER THAN 1'/12' UP TO 2'/12' ALT 062 INTERNAL U CUP 3',3'X.063' ALUMINUM COLUMN H&W=12'x12' FOR GRADE SLOPES GREATER THAN 2'/ NEW SLABS TO HAVE EITHER 6'x6'-#I0/IOW COVERED ADDITION OP FIBERMESH l� V 2',2'x062' ANGL /16-18 HEX HD BOLT, WASHERS &NUT , 250 FOOTER NOTE TYPICAL SIDE ELEVATION EACH SIDE CORROSION RESISTANT(2) 2500 PSI W/ 1 #5 REBAR CONTINUOUS : :i. 1'x2' ALUM BASE PLATE (TYP) FASTEN/TDOCJONISTS 2 NOTE: MAY ALSO BE CONSTRUCTED ON WOOD DECK W/#Ex3 DECK SCREWS I hereby certif that I have 3000 PSI CONCRETE 2'X2'X2' FOOTING Y perforr�ed and reviewed this 'plan and found OVER CLEAN COMPACTED SOIL it to be in compliance with ASCE 7-02 & R301 of the Florida Building Code, 2004 edition, 3'X3'X.06' MIN ALUM COLUMN IMBEDDED 2' MIN IN and the 2006 SUPPLE ENT t FBC 04, PIER WITH I a 5 X 12' REBAR MOUNTED CROSSWISE David W. Smith,P.E&CENTRAL THRU COLUMN APPROX. 4' FROM COLUMN END T 2'x8' PERIMETER JOIST — PIER FOOTINGS LOCATED PER PLAN CUSTOMER: 24'MAX D.C. REFER TO INCLUDED SITE SPECIFIC SHEET TYPICAL DETAIL O TYPICAL I MAY BE USED FOR ADDITIONS TD MOBILE HOMES INDICATING WHERE CONNECTION IS APPLICABLE MODULAR & PARK MODEL HOMES AS WELL AS D.1'V.S'�TITH,M.S. ,P.E. SHEET Or ISOLATED FOOTER SIZE PER AAF 2004 TABLE 604 LOAD INDEX # A THRU O ALTERNATIVE WOOD DECK #10 TAPCONSX 3 1/2' SITE BUILT BLOCK DR FRAME HOMES. J FLJRIDA PROFESSIDNiL ENE i EER LICCNSE R,�RBER 53608 COVERED ADDITION POST TO DECK1 OF 1 ENLARGED VIEW -CORROSION RESISTANT / Custom Home Plan Service CONNECTION 2' MIN IMBEDMENT IN 2'x6' Z ( 4909 WALLASTON DRIVE-DADE CITT,FLQRIDA 33525 SCALE DATE PART NO. ALTERNATIVE PIER FOOTING DETAIL : PERIMETER JOISTS J AotN-Ri-0%5 FA7752-YI-�861 E'•"IE' ds'peeewhi rct DO NOT SCA12/O1/O8 CA 125 PASCO PERMIT SERVICE DESIGN/DRAVNCHECKED „B2„ EN,1NEER LICENCE a53eO8 SUZANNE BAHR 813-788-5314 �E).W.SVITH,P.E NOTE 3'xl2'x 032'MIN ENGINEER'S NOTES: THE FourvDATrory sHowN IS BASED GN ALUM RISER PAN ROOF FASTEN COMPOSITE PANELS TO RECEIVING CHANNEL W/#1Dx1' TEKS @ 12' O.C. EITHER TOP OR BOTTOM & 1. THE DESIGN WIND SPEED = 125 MPH , 3 SEC GUST A M;NIMUM SOIL BEARING PRESSURE / 3 SCREWS/PANEL FASTEN PAN TO RECEIVING CHANNEL W/#10x1' TEKS (3 PER PAN) EITHER TOP OR BOTTOM OF I000PSF. 2. THE WIND IMPORTANCE FACTOR IS 0.77 FASTEN RECEIVING CHANNEL TO HOST WALL OR HOST 2x4 MIN FACIA WITH #10x2' SMS OR LAO SCREWS 2 12' OC, MAX 77 3. THE WIND EXPOSURE CATAGORY USED IS 'B' (2) ROWS STAGGERED 4. THE INTERNAL PRESSURE COEFFICIENT=+/-0,18 ENCLOSED ' ______________ CATAGORY I BUILDING MINOR STORAGE SHED 5. COMPONENTS&CLADDING DESIGN PRESSURES ARE PER: 3'x4' STRUCTAL OR EQUIV. INSULATED ALUMINUM COMPOSITE ROOF PANELS FBC TABLE 1609,6B OR R301.2(2) FOR A MEAN ROOF HEIGHT DETAIL F / FASTEN TO DBL 2X4 TOP PLATE W/#10x4 1/2' SEAL/WASHER HEX HEAD SCRWS. LESS THAN 30 FT. \AN FASTENIN ,/ 12' D.C. AT ENDS & RAKES ROOF: +12/-26 PSF ZONE 1B - OR 3'x12'x.032' RISER PANS FASTEN TO DBL TOP PLATE W/ 310x1 1/4' TEKS (3 PER END) WALLS: +25/-27 PSF ZONE 4B ALL FASTENERS TO BE CORROSION RESISTANT #10 X 1 1/2' HEX HD CORROSION RESISTANT METAL SCREW FROM FBCR TABLE R502.5(I) &WASHER&SEAL INTO DBL 2x4 TOP PLATE 1/2' PLYWOOD SHEATHING EXTERIOR BEARING !BALL W/UP TO 20' BLDG WIDTH APPROX 6' DC MAX. (TYPICAL BOTH SIDES) FASTEN PER STRUCTURAL PANEL NOTE HEADERS SIZE MAXIMUM 2x4 EDGEWISE BLOCKING BEARING WALL SPAN AT PANEL EDGES DBL 24 TOP PLATE 2-2'x4' 3'-6' TO PROVIDE NAILING ✓/ CORNERS LAPPED 2x4 STUD CONSTRUCTION 216'0.C. 2-2'x6' 5'-5' WHEN WALL HT. #10 X 3' HEX HD CORROSION RESISTANT METAL SCREW USE SPI HURRICANE CLIPS AT ROOF & CEILING GREATER THAN SPAN &`✓ASHER&SEAL INTO DBL 2x4 TOP PLATE BOTTOM PLATE & SP2 AT DBL TO 2 2'x8' 6'-10' OF PANELS APPROX 2 1/2' O.C. MAX. (3 SCREWS /PANEL BOTH ENDS) PLATE TO STUD CONNECTIONS 2-2'x10' 6'-5' AS SHOWN ABOVE @ DETAIL 2 LOCATIONS SPECIFIED IN F STRUCTURAL PANEL FASTENING NOTE 2-2'x12' 10'-0' � � �� 3-2'x12' 12'-2' TYP WINDOW MAY BE _l rLOCATED AT ANY SIDE DBL 2X8 W/1/2' OSB ND REFER TO ABOVE HEADER SPAN TABLE P2 FOR OTHER DOOR WIDTHS TYP 2x HEADER I IMPSON MST x Q LOCAT OR Q ON'AT T IS SH 3030 +26 PSF- cv -28 PSF- +25 PSF -26PSF O O SIMPSON SPH4 R EQUIV SP1 fTYP f . . f Jj ,J.: EXTERIOR FINISH H ' EXTERIOR FINISHED PER OWNERS SPECIFICATIONS SIDING OR STUCCO AS SPECIFIED BY OWNER -- 16' MAX - LENGTH TO SUIT SECURE TO SLAB W/ DOOR STRUCTURAL PANELS PT 2'X4' BOTTOM PLATE 72'X78' PREHUNG NOTE: 1/2' CDX OR OSS STRUCTURAL PANELS SHALL NOTE: NO FOOTER REQ' I/2' D EXCEPT WHEN ADDRESSING ERROSION EXPANSION BOLT NOTE: INSTALLATION OF DOOR TO BE OVERLAP THE TOP MEMBER OF THE DOUBLE TOP PLATE AND THE PT. BOTTOM PLATE 4' 2500 PSI NOMINAL SLAB W/O FOOTER MAY 3' IMBEDMENT 2 1/2' MIN EDGE DISTANCE PER MANUFACTURERS SPECIFICATIONS BE USED ON LEVEL GROUND UP TO SLOPES OF 1'/12" 24' O.C. APPROX., WITHIN DBL HEADER JACKS TO COMPLY WITH 110 MPH WIND SPEED Rows OF 1od NAILS 23' O.C. SHALL BE 1/2' 1' OF C❑RNERS&EACH SIDE OF MINIMUM FROM EDGE OF BOTH MEMBERS OF TOP PLATE H&W=12'x12' FOR GRADE SLOPES GREATER THAN 2'/12' D❑ORS&WINDOW OPENINGS REQUIREMENTS & DBL ROW AT BOTTOM PLATE PANELS SHALL HAVE NAILS AT SPECIFIED SPACING OF 6' O.C. NEW SLABS TO HAVE EITHER 6'x6" X10/IOWWM CAULK AND SEAL DOOR BEFORE FASTENING 2 VERTICAL EDGES AND 12' MAX IN FIELD OR FIBERMESH TYPICAL SIDE ELEVATION NOTE: WHERE WINDOWS OR DOORS INTERRUPT THE WOOD STRUCTURAL SHEATHING AND WITHIN 4' OF r EACH CORNER AND ATTACHMENTS TO EXISTING STRUCTURE I hereby Certify that I have perForrned and reviewed this plan and Found / FOR PARK MODEL MOBILE HOMES/'MODULAR HOME ADDITIONS USE SIMPSON SP2&SPI OR E'JUIV 2 TOP&BOTTOM PLATE/STUD Florid a Building �5 CONNECTIONS APPLIED PER MFCRS SPECIFICATIONS it to be in COllp�lanCe with Section 1609 of the ing Code, 2004 edition �L * S . D .NV. SLIIrI iI�1�1 7 . ,p ,E PAN ROOF `J/ STUD WALL CGNST. SHEET OF and ASCE 7-02 & Section R301 Of FBCR 2004 &the 2006 SUPPLEMENT to FBC 04„ FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 WOOD FRAME SHED Custom Home Plan Service 16' W X LENGTH TO SUIT I OF 1 J 19909 WALLAS TON DRIVE-DARE CITY,FLORIDA 33525 SCALE I DATE I PART NO. \(" FHp !352.521-0865 1AX:352-52I-0867 E-MAIL': drsTI Feorthunknet AS NOTED I 12/08/08 SHED 01-16 David W. S nith,P,E. I PASCO PERMIT SERVICE DESIGN/DRAN CHECKED --_-- - ENGINEER LICENCE X53608 1 SUZANNE BAHR 813-788-5314 D.W.JMITH,P,E, 120