Loading...
HomeMy WebLinkAbout09-8742 (2) ENGINEER'S NOTES: - 120 MPH1, SCREENED WALLS NOT SUPPORTING ROOFS OR GUARD RAILS 3 SEC GUST POSTS CARRYING LATERAL SCREEN PRESSURE (14 PSF) LOAD ONLY BASIC WIND VELOCITY. 120 MPH POST EXTRUSION POST SPACING/ LOAD WIDTH IMPORTANCE FACTOR: 0,77 SIZE i f EXPOSURE CATAGORY! B POST SPACING -0 4'-0" 4'-6" 5'-0" 5'-6" 6'-0" 6'-6' 7'-0" INTERNAL PRESSURE COEFFICIENT0.0 LOAD FT + x 56PLF 63 PLF 70 PLF 77 PLF 84 PLF 91 PLF 98 PLF = C&C DESIGN WIND PRESSURES PER TABLE 8301-6.2(2) EXISTING COVERED ADDITION COLUMNS 2'x2'x045' HOLLOW tS 8'-O" 7'-6" 7'-0" 3'x2 HOLLOW 9'-0" 8'-6" 8'-0" 7'-6" 7'-0" - - - - - _ 2'X3' HOLLOW n 10'-0" 9-6" 9'-0" 8'-6" 8'-0'" 7'-6" 7'-0" ==: 1'x2' ALUM BASE PLATE (TYP) < : 2'x4' HOLLOW I2'-0" 11-6" 11'-0" 10'-6" 10'-0" 9'-6" 9'-0" DECKING OF CHOICE ;; FASTEN PER MFGRS SPECS #10 TAPCONSX 3 1/2' -CORROSION RESISTANT 2' MIN IMBEDMENT IN 2'x6' PERIMETER JOISTS 1x2 ALUM SCREEN OPEN BACK CHANNEL ADDED TO SIDES OF EXISTING -�" 24'MAX O.C. -� ALUM COVERED ADDITION COLUMNS TYPICAL W/ #10x1 1/2 SMS 2 18' O.C. TYPICAL 1x2 ALUM SCREEN OPEN BACK73'x3' DE'T'AIL OF CHANNEL ADDED TO EXISTING BEA EXISTING M OPEN BACK ADDITION TO POST &WOOD DECK EXISTI.045' AL COLUMN W/ #10x1 1/2 SMS CONNECTION TYPICAL ALUM COLUMN SIZE PER ABOVE CHART r ADDED AS SHOWN BETWEEN EXISTING POSTS 1X2'OPEN BACK SCREEN CHANNEL - I __ ___ LL 7FASTEN TO EXISTING COLUMN iiiiuu1f/ 2'xU W/ #10x1 1/2 SMS 218' O.C. 1 M KICK PLATE SCREEN ' SCREEN BEAM 1'x2' ALUM C • BASE PLATE (TYP) / 33 ALUM FLUTED COLUMN #10 TAPCONSX 3 1/2' . .. ONC. SLAB -CORROSION RESISTANT _.._.._.._.. _. _.._.._.._.._.._.._. - 2' MIN IMBEDMENT 1x2 ALUM SCREEN OPEN BACK -6 24'MAX O,C, --- CHANNEL ADDED TO DECK TYPICAL VARIOUS LENGTHS PER DETAIL DETAIL OF OPEN BACK ADDITION TO POST & SLAB TYPICAL FRONT ELEVATION CONNECTION ADDITION OF 2X2 & 1x2 OPEN BACK MEMBERS CONVERSION OF EXISTING COVERED ADDITION TO SCREEN ROOM PRCtJECT SL MARY CO ERSION OF EXISTING COVERED PATIO TO SCREENED ROOM I hereby certif that I have erformed Qnd reviewed this Ian Qnd Found x2 SCREEN CHANNEL TO SIDES OF EXISTING ALUM. POSTS, BOTTOM OF TILT BEAMS& AT DECK SURFACE y P P A x2 SCREEN GIRTS TO PROVIDE FOR ADDITION OF SCREEN it to be in compliance with ASCE 7-02 & the Florida Building Code, 2004 Edition c D .. W . S�IITlf�i , P E CONVERSION OF SHEET OF COVERED PATIO TO and all revision & updates thru the 2006 Supplement to FBC 04, FLDRIDAPRffESSIMEK,fNCERLICER5ErlR�BCR53608 1 OF Custom Home Plan Service SCREEN ROOM Zi �J� 9909 dALLAST0N DRIVE-DADE CITY,FL0RIDA 33525 SCALE DATE PART N0. OCI52-521.0%5 rnx352.52I-0867 C-PAIL: asr wi,rni 1/4,=TFT 12/29/08 ENGINEER PASCO PERMIT SERVICE DESIGN/DRAVN CHECKED SCRN-06C David W. Smith,P E, LICENCE U536O9 SUZANNE BAHR 813-788-5314 D.W.SMITH,P.E.