Loading...
HomeMy WebLinkAbout09-9831 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780 -0020 9831 BUILDING PERMIT Permit Number: 9831 Address: 6606 6610 STADIUM DR Permit Type: RE -ROOF ZEPHYRHILLS, FL. Class of Work: ROOF REPLACEMENT Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 02- 26- 21 -001B- 00000 -0010 Improv. Cost: 22,000.00 Date Issued: 12/07/2009 Name: PICKERING, MICHAEL & SUE Total Fees: 140.00 Address: 4201 BAYSHORE BLVD #1701 Amount Paid: 140.00 TAMPA FL 33611 Date Paid: 12/07/2009 Phone: (813)882 -0586 Work Desc: ROOF OVER EXISTING MODIFIED FLAT ROOF �. . WI • R ' s • • MM R IAL 140.00 > > ,j '► + = YIN =•• I - - TAPE JOINTS R OF INSP FINAL — ( L f —f (J REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to any one of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." CONTRA R SIGNATURE 64 1ERM 2V IT OFFI r /44 /: ERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER ASUM AN 170 PRODUCT DATA Polyester i11iMMIS rim DESCRIPTION AWAPLAN 170 is reinforced with a 180 g/m nonwoven polyester mat saturated with asphalt and coated on both sides with SBS rubber modified asphalt and surfaced with cep amic granules for protection from ultraviolet degradation. . USES Roofing membrane in Series 200 Specifications and flashing membrane in select TAMMY flashing details. Easily applied by mopping in hot asphalt or approved cold adhesive_ ADVANTAGES • Exceptional performance characteristics over a broad temperature range • Excellent cold weather flexibility • High puncture and tear resistance • Cold or hot process application • 12 year limited material warranty I - • High elongation • Minimal dead load weight • Superior nail full- through characteristics ' CERTIFICATIONS U.L Classified Membrane tor Roofing Systems - , FM Approved' ASTM D 6164, Type l Miami Dade County Approved ICC -ES ESR -1013 • Roar b G A604 Cxa;4h>. TYPICAL PHYSICAL PROPERTIES Tensile Strength MD = 131 LBF/IN (W 0 deg F & 0.08 in/min) CD = 96 LBF /IN Elongation MD -=- 5696 (CO deg F & 0.08 in/min) CD = 58% Strain Energy MD = 37 IN- LB/IN (00 deg F & 0.08 in/min) CD = 28 IN- LB/IN2 PROD DATA' Tear Strength MD = 140 LBS Reinfor emerrt 180 g/m Polyester Mat CD = 106 LBS Asphalt Modifier WS Roll Weight 94 Ibs (42.2kg) Low Temp Flex MD = - 20 deg F Roll Size 33'11" x 39 -3/6" (10.3m x 1m) (PASS) CD = -20 deg F Productckness 145 mils Teeth were conducted using ASTM 0 5147 rest methods. Coverage 1 square WI vales elated as nominal and CAUTION: The National Institute for Occupational Safety and (NIOSH) has concludcd that fumes of heatod aa are a potent ocx apatiothal carcitlOgtn Apply heat to this product on w hop requ ited for proper app ileation on i n a we vent area. A void breathing the fu nes, and avo Health sk co uact. Do not burn this product. Cenral District 220 West 4111 Street. Jape+, Mia4ari 64801 e00- 941 -4(91 Northern Oi6 ct 4500 Tenon Drive, Frad,ddc. rwyland 21701 800 - 368-2055 Southeast District 2300 35th Street. Tuscaloosa. Alabama 35401 t100-228-21158 r f Southwest District 7910 South Cenral Expressway, Dallas, Texas 75216 800+443.1834 weslam mina 5300 43rd Avenue, Delmer, Colorado 80216 600-53048866 T 1 i 1 I '` ) tamko.com MAIM PINWIINS T4MKa► is a replayed trademark oh TAtaCO ttulano Prod. , Ins. .P25470 5006 "MIME, 17 d £8L00000£9 'ON /1717: l l '1S /517: l l 6002 £Z AON (NOW) WOdd H TECHNICAL DATA SHEET enrg. HE553 - MBA GOLD MODIFIED BITUMEN ADHESIVE SI OMNI. 91111.9.011919. • Last 14, Date: 000412000 1E112 Lap Peel Strength Specific Gravity 0 77 F (28'C) Glossy black, fibrous >30 lbffin I 1 0.99 ( Color Maxinurn VOC Suependability • Black 390 WI I Sages slightly Consistency 411) Tr F Maximum VOS Weight Per Gallon I Squeegee, brush, or spray 32 rbsigai I ; 7.0 Ibs Flash Point - Solids By Weight 105, 465% Manufactured to meet the requirements of ASTM 0-3019, Type III and Dade County Compliant. FM approved. Subject to the conditions of approval as a roof COafing when Installed as described In the current edition of the FMRC approval guide. APPROVED Consult Henry Representative for specific assembly ratings and requirements. mom 486-1278 See Henry Specification Manual for detailed Roofing, Reroofing, and Roof Maintenance & Restoration. HE553 - MBA GOLD MODWIED BITUMEN ADHESIVE is a fibrated rubberized adhesive with a bonding strength designed specifically for adhering modified bitumen and asphalt coated membranes to properly prepared surfaces. it sets by loss of solvent content through evaporation. Because of its ease of application. economical cost and strong bonding. it is widely used in application of modified bitumen cap sheets. Lap strengths far exceed minimum requirements of ASTM D-3019. HE553 - MBA GOLD MODIFIED BITUMEN ADHESIVE has excellent low temperature flexibility.. It does not require red label solvent idendfIcation. Hot for eau in the following areas: California South Coast Mr Quality Management District (SCAQMD), New Jersey, Connecticut, Maryland, and District of Columbia. Contact Henry Customer Service for alternate products in MOSS MOW HE563 - MBA GOLD MODIFIED BITUMEN ADHESIVE is especially formulated for use as a cold adhesive over asphalt coated base sheets. HE553 - MBA GOLD MODWIED BITUMEN ADHESIVE Is designed! to be used to adhere modified bitumen membrane having no polyethylene backing. It has many advantages over the usekd hot asphalt in applying modified asphalt sheets. HE553 - MBA GOLD MODIFIED BITUMEN ADHESIVE eliminates the hazard of hot kettle fires around industrial plants. Roofing can be applied under controlled conditions. The hazards of torch application, as well as hot asphalt fumes and odors. are eliminated. I 4 1.5 gallons per 100 square feet. Al surfaces to be coated with HE553 - MBA GOLD MODIFIED BITUMEN ADHESIVE must be dry, swept clean, and free from oll. grease, rust. scale. loose paint, dirt and other foreign matter that would knerfeie with a good bond. Hem Company - 909 P4OFtTH SEPULVEDA BLVD., EL SEGUNDO. 90240 Tectrical Santos - 800-400-1378 En: Isch6erikeiallenlYi9 wowhorry.cam 9 d £8).00000E9 'ON/tt: '1S/9tr: I 60E 2 Z AON(NOW) INOdJ i Stir in container and apply by notched squeegee, brush or suitable spray equipment. A notched squeegee with notches 114" long. 1/8" deep and spaced 1" on centers is preferred method for smooth surfaces..For irregular surfaces, the notch should be 1/4" deep. Average application rate is 1.5 gallons per 100 square feet. Do not over apply. Sufficent adhesive should be applied at laps to result le a visible bead of adhesive at competed lap . edge. Modified Bitumen Membranes should be cut In maximum 15 foot lengths and membrane allowed to relax on job site. Laps must be walked in or rolled after application. A Speeflow or Greco pump capable of deilvertng 3-5 gallons of mastic coating type material per minute is suitable. A pole gun with suitable spray tip orifice (usualy 80 to 80 mils), without a breaker bar, is recommended. The material hose should be heavy duty, 3/4 inch I.D. air hose from pump to gun is preferred. When spraying at ambient temperatures below 70°F, use an in -line warmer to reduce back pressure and increase speed of application. Do not allow the material to exceed 110°F at the tip. CLOSE AIR INTAKES ON ROOF UNTIL SOLVENTS DISSIPATE! NOT RECOMMENDED FOR USE ON EPDM OR PVC SHEET ROOFING, W000 SHINGLES, OR OVER GRAVEL. NOT TO BE USED F,OR MODIFIED BITUMEN SINGLE PLY PRODUCTS WITH POLYETHYLENE BACKING. SOLVENT VAPOR CAN PENETRATE POROUS ROOF DECKS SUCH AS WOOD, PLYWOOD, OSB, CEMENTIOUS WOOD - FIBER PANELS, AND LIGHTWEIGHT CONCRETE. THE UNDERSIDE OF THESE TYPES OF ROOF DECKS MUST BE PROPERLY VENTILATED TO THE OUTSIDE TO PREVENT ODOR INSIDE THE BUILDING. HE563 - MBA GOLD MODIFIED BITUMEN ADHESIVE does not freeze. Cold weather will cause 11 to stiffen, making application difficult. Store unopened container in a warm area at least 24 hours before using. This product is ready to use. Do not thin. Do not heat container or store at temperatures greater than 110° F. When transporting this product, be sure the pall is secured and the lid is tight. Do not allow pail to tumble as this may loosen the lid and allow leakage to occur. Not all APP torch down membranes are alike and as such, application of HE553 - MBA GOLD MODIFIED BITUMEN ADHESNE with APP membranes may not yield satisfactory results. Please contact the Henry Technical Services Department and the APP membrane manufacturer before proceeding. Do not use this product as a coating, or attempt to seal gravel. rubber. or PVC sheet roofing, or shingles of any kind - NOTE: This adhesive, like all asphalt -based products, fomrs a small amount of water soluble material as it weathers. Normally this is not noticeable because the rain washes N away. However, roofs having a pitch less than 1/2" per foot, or ones having poor drainage. will accentuate the problem by concentrating the water soluble material le low spots. If there is no rainfall, hose these roofs off to remove the water solubies. Frequent inspection of these roofs is recommended because abnormally rapid deterioration of any roofing material may occur where water stands for long periods. Ail equipment and tools should be leaned with kerosene or mineral spirits immediately after use. Use care In handNng solvents. Clean hands with a waterless hand cleaner. COMBUSTIBLE! KEEP OUT OF REACH OF CHILDREN. Contains petroleum distillate. Keep away from heat and fame. Do not heat container or store at temperatures greater the 110° F. CLOSE AIR INTAI,CES until solvents dissipate. Contains volatile solvents that might contaminate potable water. Close container after use. DANGER! HARMFUL OR FATAL IF SWALLOWED! If swallowed. do not induce vomiting. CALL A PHYSICIAN IMMEDIATELY! Use protective measures to avoid contact with eyes and shin. In case of eye contact, open eyelids wide and flush immediately with plenty of water for at least 15 minutes. In case of accidental injection by power spray equipment, GET MEDICAL ATTENTION IMMEDIATELY! USE ONLY WITH ADEQUATE VENTILATION! ff you experience eye watering, headaches, or dizzi less, leave area immediately or Increase fresh air or wear respiratory protection (NIOSWMSHA TC 23C or equivalent). Repeatedland prolonged occupational overexposure to solvent vapor may cause permanent brain and nervous system damage, and may cause Neer or kidney damage. WARNING: This product contains detectable amounts of chemicals known to the State of Cadfomia to cause cancer, or birth defects. or other reproductive harm. EMPLOYERS should obtain a copy of the Material Safety Data Sheet (MSDS) from your supplier or directly from Henry at the toll free number or website below. 5 GALLON (43.05 lb) 55 GAL/205 L (4119 lb) We. the manufacturer. warrant only that this product is free of defects. since many factors which affect the results obtained from this product - such as weather. workmanship. equipment utilized and prior condition of the substrate - are all beyond our control. We will replace et no charge any product proved to be defective within 12 months of purchase. provided it has been applied In Homy Company -cos NORTH SEPULVEDA rive, E.5EOUNOO, CA 90245 Technical Smites -1004116-1271 Em lecfrianolcaellhanry.cian rew.heny.Crnn 9 d £8200000£9 'ON /bti: l l '1S /917: l l 600Z £Z AON {NOW) WOdd accordance with our written directions for rases we recommended as suitable for this product. Proof of pine must be provided. DISCLA R �a_� s AND LJMITA _ QF LIABILITY: THIS LIMITED WARRANTY IS IN LIEU OF ANY OTHER WARRANTE EI�RES OR N1PLEED INCLUDING BUT NOT UNITED TO ANY IMPLIED WARRANTY OF MERCHANTABIUTY OR FOR A PARTICULAR PURPOSE. MANUFACTURER SHALL HAVE NO LIABILITY OF ANY KIND BEYOND PRODUCT REPLACEMENT. INCLUDING FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES RESULTING FROM ANY DEFECTS OR ANY DELAYS CAMEO BY REPLACEMENT OR OTIERWISE. THIS LIMITED WARRANTY PROVIDES THE PURCHASER'S EXCLUSIVE REMEDY FOR ANY DEFECT IN THE PRODUCT. AI1 FORK SHALL COMPLY WITH ALL PRWAILING CODES, FLORIDA BUILDING CO 7E, NATIONAL ELECTRIC CODE ANr CI LjY OF ZEPHYRHILLS ORDINANCES V RS CITY FLAW:: Henry Camping - 909 NORTH SEPULVEDA BLVD. H. SEGUNDO. CA 90245 Tedi+lcd Services - $00.486 -1278 EmW:IOdieMCI, ry.cOr^ wwwhwry.cam L d £$L00000£9 'ON /bb: l l '1S /917: l l 6002 2? AON (NOW) WOd� _ k t , -1,` , City of Zephyrhills BUILDING PLAN REVIEW COMMENTS d Contractor/omeowner: v2 . tl . lSII� Date Received: /1 _ 2' /) Site: ry () - lv Cv /U ' t /1,114/114.... /11-• Permit Type: 3..:. i14—e- L • /r AI_ .; / , 70d -- Approved w /no comments: Approved w /the below comments: ❑ Denied w /the below comments: ❑ This co -nt sh: -t sh. be kept with the permit and/or plans. J 4I4 , ' 1 Kalvin wi F.' . s Examiner Date Contractor and/or Homeowner (Required when comments are present) Fax - 813- 780 -0021 813 -780 -0020 City of Zephyrhills Permit Application o Building Department 93 Date Received ! —. - 0 Phone Contact for Per ing if A b l i •.•u 11110 o 3 . . Owner's Name m 1 CHM ?) CKeft isle - .3 (AI , 'Owner Phone- Number 813 8yel £S8 6, Owner's Address IKaOt +✓ t �i� IhORe '81 d - /76/ 3 PAL Phone Number I V13 4 00744/ I r �� ( ( M i d/het p/CxeR /Aj& '0W O wner Phone Number I Fee Simple Titleholder Name Fee Simple Titleholder Address 1 I JOB ADDRESS I 64a 166/0 $ Thpiu l 2 zero 33542, I LOT # I /AZ I SUBDIVISION 1�7 I [ 4 an &IA I PARCEL ID 40 " 4,14 4 / - D %r ACCIDO - a7,0 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR I I ADD /ALT I SIGN 1 1 MOVE 1 I DEMOLISH n N E l REPAIR II J INSTALL PROPOSED USE I I SFR 1 1 COMM I 1 OTHER 1 TYPE OF CONSTRUCTION I I BLOCK I I FRAME 1 I STEEL I I OTHER' DESCRIPTION OF WORK I Poo 6 €I- " 2170 ` & .4 D BUILDING SIZE I - 1,5 - o0 ..sr I SQ FOOTAGE I I HEIGHT / SKI BUILDING 1 2ai0Otto . I VALUATION OF TOTAL CONSTRUCTION AR) 000 I 1 ELECTRICAL IS I AMP SERVICE I I PROGRESS ENERGY 1 1 W.R.E.C. �r 9' 1 1 PLUMBING I I �� I I MECHANICAL $ VALUATION OF MECHANICAL INSTALLATN I I GAS ,r ROOFING I 1 SPECIALTY I 1 OTHER FINISHED FLOOR ELEVATIONS i I FLOOD ZONE AREA 1 IYES LINO COMPANY I I BUILDER I F EE CURRENT Y / N 1 SIGNATURE I REGISTERED L Y/ N � � I Li cense # I I Address I I ELECTRICIAN I COMPANY I SIGNATURE REGISTERED L Y/ N 1 FEE CURRENT 1 Y/ N 1 Address I I License # 1 I PLUMBER COMPANY 1 I SIGNATURE I REGISTERED I Y/ N 1 FEE CURRENT 1 Y/ N I L icense # I I Address I I MECHANICAL COMPANY SIGNATURE REGISTERED 1 Y/ N 1 FEE CURRENT 1 Y/ N 1 Address License # I I /l COMPANY I Th OTHER /�OrI i AtON\°' REGISTERED / N 1 1 SIGNATURE E FEE CURRENT ( I N I Address 0Z /B E. tla pp � �/ 400 .0 Po/ d, 7'R', License # [eke 00316 8. I RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R -O -W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (3) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R -O -W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. "' "PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A /C upgrades over $5000) ** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroof Sewers Service Upgrades A/C Fences (Plot/Survey /Footage) Driveways -Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions, UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a.. contractor or contractors'to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division— Licensing Section at 727 -847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT /UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse.Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89 -07 and 90 -07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water /Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law — Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner ", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner ": prior to commencement. CONTRACTOR'S /OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection- Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District - Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers - Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services /Environmental Health Unit - Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency- Asbestos abatement. - Federal Aviation Authority- Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A ", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If 1 am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, Construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official 'for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR N ICE OF COMMENCEMENT. FLORIDA JURAT (F.S. 117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to (or affirmed) before me this Subscrib ?d an sworn to (or affirmed) b ore me this by ERR` by ho is /are personally known to me or has /have produced Who is /are personally known to me or has/have produced as identification. � as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed, printed or stamped Name of Notary typed, printed or stamped ?asco County Parcel: 02- 26- 21 -001B- 00000 -0010 001 http: / /www. appraiser. pascogov. com /search/parcel.aspx ?sec= 02 &twn.. Search Again Map Generalized Building Schematic Frequently Asked Questions Estimate Taxes Other Parcel Cards: 1 1 2 Other Agency Data: Tax Collector School Board Supervisor of Elections Data Current as Of: Weekly Archive - Saturday, November 21, 2009 Parcel ID 02- 26- 21 -001B- 00000 -0010 (Card: 001 of 002) Classification I 19 - Professional Service Building Mailing Address Property Value PICKERING MICHAEL ] & Ag Land $0 MICKY SUE Land $53,034 4201 BAYSHORE BLVD UNIT 1701 Building $433,649 TAMPA, FL 336111667 Extra Features $2,025 Physical Address - See All 2 addresses (First Shown) 6606 STADIUM DR Market Value $488,708 ZEPHYRHILLS, FL 33542 -7510 Assessed (Save Our Homes) $0 Legal Description (First 4 Lines) Taxable Value $488,708 See Plat for this Subdivision 1- STADIUM PARK PB 19 PG 145 LOT 1 & LOT 2 AKA RETENTION AREA OR 4153 PG 1659 Land Detail (Card: 001 of 002) Line Use Description Zoning links Type Price Condition Value 1 1900 PROF.BLDG 00C2 12,000.00 5E $2.20 1.00 I $26,400 2 1900 PROF.BLDG 00C2 17,388.00 SF $1.53 1.00 $26,604 3 I 1900 I PROF.BLDG 00C2 ) 3,000.00 I SE $0.01 1.00 $30 Additional Land Information Acres I 0.78 I Tax Area I 30ZH I FEMA Code I X 1 Commerical Code I PSTP2AA Building Information - Use 19 Offices Professional or Medical (Card: 001 of 002) Year Built 1980 Stories 1.0 Exterior Wall 1 Concrete Block Stucco Exterior Wall 2 None Roof Structure Rigid Frame w /Bar Joist Roof Cover Built -Up Tar and Gravel Interior Wall 1 Drywall Interior Wall 2 None Flooring 1 Cork or Vinyl Tile Fboring 2 Carpet Fuel Electric Heat Forced Air - Ducted A/C Central Baths 4.0 Line Description Sq. Feet RepL Cost New 1 AOF 7,200 $664,200 2 1 CAN I 484 I $13,376 Extra Fe atures (Card: 001 of 002) Line Description Year Units Value 1 PAV ASP ( 1980 1 10,000 I $2,025 Sales History Previous Owner HUFF JOHN R & BARBARA E I Year Month Book /Page Type Amount 1999 05 4153 / 1659 WD $335,000 . 1996 I 04 I 3555 / 1844 1 WD $0 Search Again Map Generalized Building Schematic Frequently Asked Questions Estimate Taxes Other Parcel Cards: 1 1 2 1 of 2 11/23/2009 12:55 P] Oct 19 09 06 :03a Wilson 813- 354 -2779 p.1 M.R.Wilson Contractors Estimate Sheet 218 E.Bearss Ave. #332 Tampa, Florida. 33613 Phone 81.3-404-4952 Fax 813 - 354 -2779 We have inspected your property today at 4606 -0 Wc/rrt D. Z P.Jvf 4,5 (-C)4111 and offer the proposal below to: c a jii Name 1) TA C1106 Phone A CST "Zepk ed. m tl cJ 71/4,‘ Sei4W.3G w c 7t! a., GUh !7* 6RAIU1J1 -e s( /e" dee !Y)DDf 'Eli AIDP d c 47r Atl (, Io . Atougs =WeLULti"S ALL P esv T, f x' mv /?A./ t 6 , )+ #f de4I- S�lc. gg ec.770,0+ v tti7 ? / �2�t.. ��r ' f ►� CAC, S. — it't - t \ocl 4:*`' Sod Your com . I repre- • n ►: 've is AICJ( B Afy Accepted by: ph .ss State Licensed Contractor CRC0036: 2, ended and Insured since 1972 BBB rated A and Bob Vila approved contractor. Ocn contractor 100098291 gill 4 riff# OCT 19,2009 05:57A 813 354 2779 page 1 This space for 1 11 1111 11111 1 1111 1 1111 11111 11111 11111 11111 11111 111 1 1 011 11 11 p use by Clerk of the Circuit Court only. 2009168813 ace Rept:1275039 Ree:10.00 DS: 0.00 IT: 0.00 11/24/09 -- - - - - -- - .- - - - -__ Dpty Clerk PAULA S. O'NEIL, PASCO CLERK & COMPTROLLER 13OR4 4 � 1 1 5 NOTICE OF COMMENCEMENT Permit Number: Tax Folio No., is - t P Oa= pQ /47 The undersigned hereby gives notice that improvements will be made to certain real property, and in accordance with Section 713.13 of the Florida Statutes, the following information is provided in the NOTICE OF COMMENCEMENT. 1. Legal Descripti.n of property (street address required): 6606 09141 bb (o $r40 fCiM • 1 . _ 1 J� , ALL,.. iv. , . D lent- / AI►►d a_ ■e.4- Re7?^n7MJ AiEd, 2. General description of improvements: ROOF °Veit 3a. Owner Name: ml Ch4?eL ,' 3 ci eR, jc Owner Address: #aQ '$,/md /7o/ MO" ) 2 . 336 3b. ,Owner's interest in site: X1.31 ,R„ 3c. Fee Simple Title holder (of other than owner) - Address: Contractor Name: A. 1411.4. j Address: os E FaX64.5 f TifrOieL 334,1 r Phone: 873 4S94 5. Surety Name: Amount of bored: Address: Phone: 6. Lender Name: Contact: Address: Phone: 7. Person within the State of Florida designated by owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7, Florida Statutes. Name:A /Come 9 i Ger—AV . Address:4 20/ 847.sAodu. gA'z .?#ITOI nrkx Phone Number: 813 •Z etz 4G,/ 8. In addition to himself, Owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name: Riekt ale -4y - Address: Po. $a q . TAMPq 33b Phone Number: 81 46 4 ( EI3Z 9. Expiration date of Notice of Commencement (expiration date is one (1) year from date of recording unless a different date is specified). WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Signature of Owner wner's Authorized Officer /Director/Partner /Manager STATE OF FLORIDA COUNTY OF HILLSBOROUGH The foregoing instrument was acknowledge before me this 073 day of / M'aegi 20 Clq by Rl6IMf• Om , as MR6l for_ le e1Mei. F'scirseara G Personally Known V OR Produced Identification Type of Identification Produced , 3 P GARRE - MY COMMISSION # DD.,' "^ / • ; -to EXPIRES November 03, 2012 107 316.0153 F icridoNotarykervics.ebn Signature - Notary Public Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. &/d Signature of Natural Pers igning Above (A copy of any bond t be attached at the time of recordation of this Notice of Commencement) Updated February 2008 STATE OF FLORIDA, COUNTY OF PASCp % &)t.!,•‘` THIS IS TO CERTIFY THAT THE FOREGOING k ' ., ! i �h _ . TRUE AND CORRECT COPY OF THE DOCUM Nt� , ,�1,,„,y, '� . ON FILE OR OF PUBLIC RECORD IN THIS 0P 3C " _ WITNESS MY HAND AND 0 FICIAL EAL THI g\ ! y ( ' � Z, DAY OF C 2 o a }; , • 3. PAULA S i'NEIL, CLERK & ?MPTR• f BY / 0 � j py!r� �1;1 � ii -1 / r lir RK •/