Loading...
HomeMy WebLinkAbout09-9888 CITY OF ZEPHYRHILLS • 5335 - 8TH STREET (813)780 -0020 9888 BUILDING PERMIT 0 ... f:" �. Permit Number: 9888 Address: 5301 19TH ST Permit Type: RE -ROOF ZEPHYRHILLS, FL. Class of Work: ROOF REPLACEMENT Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 11- 26 -21- 0010 - 17700 -0040 Improv. Cost: 3,685.00 3�,_� ,el °` . .0 3., Date Issued: 12/11/2009 Name: STRUBLE, KEVIN Total Fees: 75.00 Address: 7645 FORBES RD Amount Paid: 75.00 ZEPHYRHILLS, FL. 33540 Date Paid: 12/11/2009 Phone: (813)469 -7771 Work Desc: METAL ROOF REROOF OVER EXISTING SHINGLE ROOF - Y AN RO• FIN R• • R SIDENTIAL 75.00 IOW �� � ..E.etAgr r �F, -. ..�.x 6. .. _ „ .�, x33 E �.. �. DRY IN R•OF TAP ITI1S ROOF INSP f 4 REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to any one of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." CONTRAC SIGNATURE PERMIT OFFI rR PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION — 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 2009177566 Rcpt:1277787 Rec: 10.00 DS: 0.00 IT :0.00 12/11/09 Dpty Clerk • NOTICE OF COMMENCEMENT PAULA S. O'NE1 : PASCO CLERK CLERK & COMPTROLLER 12 OOR 1 BK 9 8 L PG 0 YJ ic 1954 Permit No. Property Identification No. j1- d — (_QI0 - /77 0040 THE UNDERSIGNED hereby give informs you that the improvement will be made to certain real property, and in accordance with Section 713.13 of the Florida Statutes, the following information is provided in this NOTICE OF COMMENCEMENT. J � i d $ I.Description of property (legal desc , t � � Z2 t 4 )' 1 „ a .. J. - i 6.-P Lo-1 38 � 1'� 7 a) Street Address: * Lir�`�s��� 7T: IWI _ 2.General descrip ion of improv .. ents: n i • i • � l%T► a 1r lV a a?i Js �.',777it1P.l Yt�f 3.Owner Information f / ��)) f ' / a) Name and address: We iii ru 6 /P. 1 ,t 5 Forbes Rd . 7 .A yr �,' 33..CY' 0 b) Name and address of fee simple titleholder (if o than owner) J c) Interest in property 3 y Frontractor Information A,,/) ,? . (•V _II J a) Name and address: p W, / f 7 P/34/ `/� 1 I k L 33.; yl b) Telephone No.: 1 i 1 • - Fax No ( tc) //( V 5.Surety Information a) Name and address` , b) Amount of Bond: // c) Telephone No.: Fax No. (Opt.) 6.Lender J� a) Name and address: r / Phone No. 7. Identity of person within the State of Florida designated weer upon whom notices or other documents may be served: a) Name and address: ./Yon LJ SI , • b) Telephone No.: / / J 777() Fax No. (Opt.) 8.In addition to himself, owner designates the followmg person receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes: a) Name and address: . b) Telephone No.: -- Fax No. (Opt.) 9.Expiration date of Notice of Commencement (the expiration date is one year from the date of recording unless a different date is specified): • 7g. _ WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF i , a `: ; L COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, . . ' FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. . A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST 1. '. INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR AN ATTORNEY BEFORE 1 COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. . STATE OF FLORIDA . _ .. —i= COUNTY OF PASCO 1 / . I. I ..11 11 ►�� L � as + Si 'oza .. . a .' Au .or •-• Offi sirector/Partner/Manager Print ame ' (n W ti to W U The foregoing instrument was aclmowledgeil before me this // day of �(� e j " , 20 t , by U O .o <3 i -1 r as ev K 4j r ,e (type of authority, e.g. officer, trustee, attorney O 0 W j N in fact) for t ,P/ Q name of party on behalf of who •. ' . • ∎ent was e. -, uted). d O a W H W Personally Known _ OR Produced Identification f/ N otary Signature / , j 1. . at_, // C , k„ O _ - - 11 Iry ,ems erg, r� n T`� 1 >' O LL 0 <,„„ _ 0 , ..1(rir?:iU1vFIG () 1- Type of Identification Prodduced rt< D /r t VE,VS Lic . Name (print) = I - O > - U Y \ 1 Verification pursuant to Section 92.525, Florida Statutes. Under penalties of , I decl 147.34045y¢ Y flt. d at Q 1- < U the facts stated in it are true to the best of my knowledge and belief. 401,41 0 >- U 03 0 LL u_ O � � - -- a F Ct a Q > W i AA A....4 � �` 0 CYD LL.} . Az Sign' o Pers. •' gni ..... .Above -J t.tW 0 0 FORMS/NOC•rv,007 Lt. 0 U cc O d2 O CD 0 W cnQuww 1- I ct z co 813- 780 -0020 City of Zephyrhills Permit Application Fax -813- 780 -0021 Building Departmen Date Received Phone Contact for Permitting 71� ° -- V 7( Owner's Name Ke U U I S l UJI , Owner Phone Number e 3 - tog "iii Owner's Address ' ( 45 forheS Pd. Owner Phone Number Ig ) - 3 - 1 7 [ 1D Fee Simple Titleholder Name Owner Phone Number g 13-7 g -7(77 7 Fee Simple Titleholder Address 1 / JOB ADDRESS t530/ D/ / /T// J j", u 4 )`JS FL 3354A LOT# SUBDIVISION PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD /ALT 1 1 SIGN n MOVE 1 1 DEMOLISH INSTALL REPAIR PROPOSED USE SFR 1 1 COMM 1 1 OTHER I TYPE OF CONSTRUCTION I 1 BLOCK (` 1 1 FRAME � 1) STEEL � 1 l , 1 OTHER eaJ �on 'i DESCRIPTION OF WORK i n 1 e4 ove "e /� � s—ii s� /Ur !e roo-P• BUILDING SIZE SQ FOOTAGE HEIGHT ..1/1 BUILDING $ 340 TS , 0 0 VALUATION OF TOTAL CONSTRUCTION 1 I ELECTRICAL $ d AMP SERVICE 1 1 PROGRESS ENERGY n W.R.E.C. I I PLUMBING $ 1 1 MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION `S V 1 1 GAS jZir ROOFING 1 1 SPECIALTY 1 I OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA 1 IYES 1 (NO 6 BUILDER - COMPANY & /??ff — /t) /A" , SIGNATURE • '�'}►�$ REGISTERED / FEE CURRENT Y / N Address U License # ELECTRICIAN COMPANY SIGNATURE REGISTERED 1 Y/ N ] FEE CURRENT 1 Y/ N Address License # PLUMBER COMPANY SIGNATURE REGISTERED 1 Y/ N FEE CURRENT I Y/ N Address License # MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT 1 Y N Address License # OTHER COMPANY SIGNATURE REGISTERED Y/ N 1 FEE CURRENT I Y/ N1 Address License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R -O -W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions /large projects COMMERCIAL Attach (3) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R -O -W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. * ** *PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $5000) ** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades NC Fences (Plot/Survey /Footage) Driveways -Not over Counter if on public roadways..needs ROW R , NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division — Licensing Section at 727 -847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT /UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89 -07 and 90 -07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water /Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law — Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner ", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S /OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection - Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District - Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers - Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services /Environmental Health Unit - Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency- Asbestos abatement. Federal Aviation Authority- Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V" unless expressly permitted. If the fill material is to be used in Flood Zone "A ", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: • UR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMP' O EMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LEND R •�Si_i;,�RNEY BEFORE RECORDING YOUR N • ICE OF CO MENCEMENT. FLORIDA JURAT (F.S. /� �_ / r ' OWNER OR AGENT CONTRACTOR AN,A.4... C 4 Subscribed and sw. to (or affirmed) before me this Subscribed and sworn 1. (or affirm L' e .) bef. me this by by Who is /are personal v knownso me or has /have produced Who is /are personal) known to me or has /have produced as identification. as identification. '(Z-- /� }Lary • Publ 7( . .. /'G•/^ -� Notary Public Commission No. . .: .,.,d . .... -- ° J -. Commission No. . . -N,,.,,,. , ∎*6 ANN • A MARIE LYNCH -TERRY i�nr. L YNCH -TERRY 29 U ee:--, Notary Public - State of Florida -', Nnlary Public - State of Florida • a �s dbei�tpp iaP� s�Apt'�D Nam bf , + 6�nR 3t Eid�Ht 11�A[I 2012 'II oc Commission # DO 740169 u ' � ' ` Commission # OD 740169 6 ' � ; .. Bonded Thro National Notary Assn. 1 f -;' r ^1 'hi a,nh *ions &Notary Assn. Pasco County Parcel: 11- 26 -21- 0010 - 17700 -0040 001 Page 1 of 2 Search Again Map Generalized Building Schematic Frequently Asked Questions Estimate Taxes Other Agency Data: Tax Collector School Board Supervisor of Elections Data Current as Of: II Weekly Archive - Saturday, December 05, 2009 I Parcel ID II 11- 26 -21- 0010 - 17700 -0040 (Card: 001 of 001) Classification 11 01 - Single Family I Mailing Address Property Value STRUBLE KEVIN Ag Land $0 7645 FORBES RD Land $26,502 ZEPHYRHILLS, FL 335401958 Building $33,915 Physical Address Extra Features $557 5301 19TH ST ZEPHYRHILLS, FL 33542 -2175 Market Value $60,974 Legal Description (First 4 Lines) Assessed (Save Our Homes) $0 See Plat for this Subdivision .2" Taxable Value $60,974 CITY OF ZEPHYRHILLS PB 1 PG 54 LOTS 4 & 5 & THE SOUTH 1/2 OF LOT 3 BLOCK 177 OR 5999 PG 270 Land Detail (Card: 001 of 001) Line II Use °Description° Zoning II Units II Type 11 Price II Condition II Value 1 II 0100 I SFR II 00R2 II 8,400.00 II SF 1 $3.06 II 1.00 II $25,704 I 2 II 0100 II SFR II 00R2 II 2,100.00 II SF II $0.38 0 1.00 II $798 Additional Land Information Acres II 0.24 II Tax Area II 30ZH II FEMA Code II X IlResidential Codell ZHLHLP2 Building Information - Use 01 - Single Family Residential (Card: 001 of 001) Year Built 1948 Stories 1.0 Exterior Wall 1 Concrete or Cinder Block Exterior Wall 2 None Roof Structure Gable or Hip Roof Cover Asphalt or Composition Shingle Interior Wall 1 Drywall Interior Wall 2 None Flooring 1 Hardwood Flooring 2 Parquet Fuel Electric Heat Forced Air - Ducted A/C Central Baths 1.0 I Line II Description II Sq. Feet II Repl. Cost New I 1 II UGR II 280 II $3,478 2 II FEP Q 320 I I I $9,274 3 Q BAS II 816 $33,782 4 II FOP II 152 II $1,573 Extra Features (Card: 001 of 001) Line II Description II Year II Units II Value 1 CLFENCE II 1985 II 520 II $183 2 II DCFENCE II 1999 II 1,000 II $374 Sales History Previous Owner 11 FEDERAL NATIONAL MORTGAGE Year II Month II Book /Page II Type II Amount 2004 I I 08 II 5999 / 0270 II W D II $69,900 2004 II 06 II 5892 / 1795 II CT II $0 1995 II 01 II 3388 / 1794 0 WD II $50,000 http: // appraiser. pascogov .com /search/parcel.aspx ?sec =11 &twn= 26 &rng=21 &sbb= 0010 &... 12/11/2009 City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: C / Q Date Received: / {— 1/ 6 Site: 530 �% ` Permit Type: r4 irOrti Approved wino comments Approved w /the below comments: ❑ Denied w /the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Kalvin Switzer lans Examiner Date Contractor and/or Homeowner (Required when comments are present) Gulf Coast Supply & Mfg. Inc. Product Evaluation Report for 26 Ga. Tuff Rib 36" Wide over 1x4 Wood Purlins Florida Product Approval # 11651.14 Category: Roofing Subcategory: Metal Roofing Compliance Method: 9B- 72.070(1)(d) NON -HVHZ ALL WORK SHALL COMPLY WITH ALL PREVAILING CODES. FLORIDA BUILDII':G CODE, NATIONAL ELECTRIC CODE AN' 3 CITY OF ZEPHYRHILLS ORDINANCES Engineer Evaluator: Terrence E. Wolfe, P.E. # 44923 19530 Ramblewood Drive Humble, TX 77338 REVIEW DATE_a' L p Y CITY OF ZEPHYRHILLS Validator: PLANS EXAMINER S Locke Bowden, P.E., FL #49704 - ' - i`` 1/ 9450 Alysbury Place Montgomery, AL 36117 . No. 440e. • f A • • " 11. STATE OF • A• A Z O R I V' 7 ∎ 7 $1- $ 1 /1 1 1 ��� 1 of 3 November 9, 2008 Product Manufacturer: Gulf Coast Supply & Mfg, Inc. 4020 S.W. 449th Street Horseshoe Beach, FL 32648 352 -498 -7852 Product Description: Tuff Rib Roof Panel, 26 Ga. 0.0185 ", 36" Coverage, 3/4" Tall Rib, non - structural metal roof panel over 1x4 wood purlins attached to min. 15/32" Plywood. Panel Rollformer: MRS Metal Rollforming Systems 13906 N. Newport HWY Mead, Washington 99021 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2007, Sections 1504.3.2. Documentation Supporting the Compliance Statement: The product has been tested in accordance with: • UL 580 -94 / 1897 -98 by Force Engineering & Testing • Test Report #117- 0062T -07D, E dated 2 -19 -07 A) Test #1 Main Tested 9 -13 -06 B) Test #2 Edge Tested 9 -22 -06 Limitations and Conditions of use for NON -HVHZ: Maximum Roof Component Uplift Pressures: - 109.25 psf @ 9 "- 9 " -9 " -9" Fastener Pattern at 24" O.C. - 164.25 psf 9 "- 9 " -9 " -9" Fastener Pattem at 12" O.C. Panel Material Standards: 26 Ga., 0.0185" Thick material Grade 80. Panel Material shall comply with FBC 2007, Section 1507.4.3 Panel Fasteners: #9-15 x 1 -1/2" HWH Woodgrip w/ Sealer Washer. Fasteners must be Corrosion resistance per FBC 2007, Section 1507.4.4 Minimum Roof Slope: 2:12. Minimum Slope shall comply with FBC 2007, Section 1507.4.2 and Manufacturers recommendations. Substrate Description: 1x4 Wood Puffins attached to Min. 15/32" Plywood Deck designed by others Vapor Barrier: 30# Asphalt Saturated organic felt paper in compliance with ASTM D226, Type 1 or Type II. Roof Panel Fire Rating: Panel has a Class B fire exposure rating in accordance with FBC Section 1505.3 without added an additional fire barrier. O No. 449.' : • • '°' STATE OF • • o ."`,g; ZpRI1aA • .+�v sr �� S �S ,s s •ys III 1{ ?• 2 of 3 November 9, 2 0 0 8 Design Procedure: Based on the dimensions of the structure, appropriate wind Toads are determined using Chapter 16 of the FBC 2007 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support decking & framing must be in compliance with FBC 2007 Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for structural loading. Installation Requirements: Install the panel system according to the manufacturer's installation instruction. Quality Assurance Entity: Keystone Certifications, Inc: FBC #QUA1824 Certificate of Independence: See uploaded attachments Authorized Representative: Terrence E. Wolfe, P.E. #44923 O 4. 444. .' C � N � lt,i • Z • No. 4l9 L ( t. • STATE OF ; ck ►" ► 9 •. t� • A' L ORI V A •• 3 of 3 November 9, 2008 7/13/2009 4:11 PH nom: Gulf Coact Supply Gulf Coact Supply ...Manufacturing TO: 18137821975 PAGE: 001 OF D01 Gulf Coast Supply & Mfg, Inc . 4020 SW 449' St. Horseshoe Beads, FL 32648 Pik (352) 4984778 FX: (352) 498.7852 www.eullroasl8epply eom To Whom It May Concern: Gulf Coast Supply & Mfg. Inc. approves the installation of Tuff Rib® roofing panels over one layer of shingles, as allowed for in 'Section 1610 Reroofing, 1610.3 Recovering versus replacement", providing a barrier layer is applied between the existing roofing and the metal panels (nominal 1x4 purlins spaced according to our engineered spacing guide or minimum 30# asphalt saturated felt paper, Titanium UDL25® or equivalent). Installation in this manner is approved by Gulf Coast Supply & Mfg as the manufacturer, as required by the Florida Budding Code. if applied without purlins, decking must be inspected to insure that It has not deteriorated to the point that it is not adequate as a base for additional roofing. Jonathan Sherrill General Manager . , , . C5 . : • .... • . , •• (D 0 LL i LLI __I 2 LLI LL i A 4 --- - L E2 1 4- -- 0 ,5 CC - V) C.) r cn 0 01 , co ..."- —J A i, •, 0 4 CV , . 0 ( f ) W co . ' a) <cu .4.2 u)(0 co LO Ct N -- Ch (/) IL 0 —I D M 2 - - --- a- < 0 Lii . N ....1 1— , cy oa e. u) , Z I . ,..... 0 i. u) 1 Lii Z CG , .&) r W . .„ __J W LU , ..s.,‘ W e . „ 0 1 1 w < z „A , 1— ix x - u) w b > i LU a_ ...--- < • 0 ' -'-' Z 1 --- - - ''- U... 00 W To . 0 6 --I 1— .. (N Z -,1 LL1 z -- 0 0 , a. CL z &) —J < . , < CC . Tr , a 0 . 11 E sot * CL 7 1- 1 cN, (I) LI- D Ts . A ' CO Ct 0 a i U-1() ‘ t 0 01111 ,,,,, CO 1 (I D Z Ce }--- - ..• , 1 ... . :Iti *** 0 P 5 it . , .1 : 7 ' ., . ' ' • aNt ../.... 0 Z ON i • 0 .; CN1 rn . ,Z 0 Cr -c-6 ',' ' . ",' : , A- 1- •:. - 17 : ; , .. ..." f ; P II " c; l' -- -- • _1 7, , . c4 . . 1 / • =N , . . , L , '1 7 4 4. \ ..) CC • < : P 7. ' _ 4 _ 4 N , i . • e6 (ll 1 ', , , , . c ) .• "' . . • • • • • • Ilo% 0 • . • / r' . _ z al ' - - • -1.f i 1 i 1 c‘i , . - . 0 Z co ,t- _ (0 0 CJ 01 1 L P 9 L (,) „, a L _ . Lu a 1J / 1 ".1 1,11 __I .e LU U- 0.5 CC - LO a II m cn D nt 03 ( 7,5 U) LIJ co > ' f- CI) k..) 00 (I) stD CO < C•1 ( 0 0 0 111 LU Z o d' CO Ce U.1 LL 0 , -J U) '-' 5 D 1 O ' , CD C)` 0 z i o < WO , LLI LLI Z i 0 l r , e : ; P 4 / . . i 4 i I 1 L ZWw 1 i I 1 -r— 1 I t % 1 1 v cn co 46 0 co z : i ' / -,1 . , , , •iii. 0 s-1 , -J o w - ...c W Z ,' * 4 1,i : I Z CO I I-- o Ln Lu i ' i 1 ' i / , , Z 0 o ,,- < W i , 1 /,' , u) < Q co > - '---- 1 Z CO cr ' I I , l ) 7-1 0 / , ! ir. _ CC ' i ' D Z .i Il Fe w ve z , , o 0 . .' --7- (1) 0 < ' 0 0 0 c., > I w a. '/ i i '/' w 0 0 lit x d is 01 , II d 3: 3: i 0 cn Co ' - L a) 2 R . v• co ,1* A * T1 Z EL x - H LI 1.1_ - WI LU u_ U) 0 ss ssuli,,, Z -.L. CL I- 0 "q • . < w • \.• • 14,'N' • • • v/ c .:• 0 .• ...,••• 0 : CI m CC i 4... • w a. 5R ., 0 u) W .- • c 04 14 D 0 - -- -.1 . Lu Et • < : .. 44 r. i Li : W -z 1...‘ • z : a) 44 0 Z . ° : F— 0 : .9 w F_, -... -1.- • -5 ..-::: 0 --#•,--_-,... E-4 > w : x.\> • •' --.. •• W , i:.. •',,co ; > ai cr w • cs/ o a. 4”. ,... • z < 0 ' ''' grta! w _ ---, (.1 - - 26 Ga. Tuff Rib 36 Wide over 1 x4 Wood Purlins RIDGE RC-2 STYLE RIDGE/HIP FLASHING 9-15 X 11/2" WOOD SCREW W/WASHER [8 PER PANEL] 9-15 X 21/2" WOOD SCREW [SEE PANEL INFO. SHEET] W/WASHER (9" O. C.) (THROUGH RIB) OUTSIDE CLOSURE ' 1 , OUTSIDE CLOSURE OR VENT MATERIAL OR - - -- , 2 . coal' VENT MATERIAL ----':- _ . -- - _ - 4. Il lik ., -,--;---.----%-- .,.. * - -- : ....-,-, ..,-- ,....... ___ „....--y ” -- ..--:---:- - ' co' .1-_-- „,...._.! - 0 . ... -- - ---:- - EXISTING PLYWOOD 1x4 WOOD PREFINISHED PURLINS APPROVED UNDERLAYMENT TUFF-RIB PANEL OR EXISTING ASPHALT 8d X 21/2" RING SHANK NAIL SHINGLES *UP TO 2" OF DECK SHEATHING (4" O.C. MAY BE REMOVED FROM EACH SIDE OF RIDGE FOR VENTILATION HIP 6" CONT. HIP RC-2 STYLE RIDGEJHIP FLASHING SEALANT MATERIAL 9-15 X 1Y2" WOOD SCREW 9-15 X 2W WOOD SCREW W/WASHER [8 PER PANEL] I , W/WASHER (9" 0. C.) [SEE PANEL INFO. SHEET] _.-- ----„, (THROUGH RIB) .. - __---- __ .., .. _ ______- - — ._______. ---_,-__ a.: .... - -4 - - -- z-:-__,-.-",.. . EXISTING PLYWOOD _ :_ 4 __,- - - - - 1 , ".-";-- ... . 1x4 WOOD ' 1 - __- PREFINISHED PURLINS APPROVED UNDERLAYMENT TUFF-RIB' PANEL OR EXISTING ASPHALT 8d X 2W RING SHANK NAIL SHINGLES (4" 0.C) ,,, ,,,,, .. • , a Q *** C, E N s '.. 40 .• % . v RC-1 STYLE RIDGE/HIP FLASHING z i... . N . i : I o 449 • I : Slab ot Raft : * : * : * : C4A. *MO GULF COAST SUPPLY & MFG., INC. -; spOF :3 4020 SW 449 STREET 0 .4. HORSESHOE BEACH, FL 32648 0 R k ...\• &,.% 888-393-0335 P .--i-• el - November 8, 2008 , ; k...) Z „co ".... 'V (0 , C\1 Lu u_ pa 111 LLJ a- Z i CO 0 LLI o_ 2 e ' , - ■ - 1 -1-1 Z CO 0_ co co F.- D ap C) < < H z cc . kt . , . z el r Z ii: LL. • 0 — CO D I- 111 la- I !'■ > C < CV ( I ) 6 6 ----•- CO 0 U) '' 0 ° 0 0 W I 1 1 t , Ct 0 •tr u) 0- Ct o_ z 0 ,... • D 1 co 1 0 - N U.1 .• W l- 1 __I —.1 WI • -1111. :s. 1 -J 4 1 TE CO J., 1 Z 1 0 ■ I 1 ' Z $ ■ ' Z U") < .1 7.1 a. ,,,.. 1 ■ , ce --I D a_ Ea a 0 N q o ...., , 4,1 Q ..-44.. ,.-• 0 X 0 V I I 73 2 U) W cr - ,.... 4 1 x , 'CI 11 - 0 0' ■ 0 w '• 0 *. 3 n C 13›- ..... -......, 1, t' 71 :4 • 0 '0.. 0 H 4 ,• - - 1 • Ir '4 CL. ..' 0 0 . 0 .yi......-• I. 4.44;.,, .. ..:.. ..Alfr . ..." 4 . - V 'V. s :•:* ,', WC* VS' eeltariel : `, N.,, 1 Z 1 .... I -1 E ,....... (1) LO -' Z 5 \ / 0 :3 LU = Z CC m Y D - ro . ,,,,,,, i co 0 (1 o 0 z C4 • • • ... A, .„, „, 03 w •,'.::: • . v /0"•:, - 4-i ......%-‘ 44 4- • 1- - 8 .• • ,_ n• Wt. °D OW 0 - • i *. El •t Lif • -.. . . CCI •.• • .C... . ••••• • ....... IN .. 1 • : ill : L■1 • • < r• (1) RS : 0 • 0 a - - 1> .■ \)-\ . C° ' > . .■-■ ,:*** 0 4., u . • . * • - - Z 4.,*‘,., *.* ••-• . 0 ,- , "•*;' * • •• w U Z o0 0 U _ N cn 0 p W J Z OM Fc w CL WLL _ I S J �= O ?' c/? U�"� co W X m a�wM Li a in D co u) LLI 06 A O N W ill I ' 1 CC IL • O = M ; D e • 0 W ■ • \ c r 0 0 I —j p Q O _ z ifl Y O ;_ 0 � ; z Q O J S \ _ Zor Co Y m xQ i Ua Z 0 to a w� I ►r.I o N0 U O x O Z w . � m a J X x � ,-I 'COD _ _ Z Q J w S0 i 4 i o w '. g Q 13• I 7 5 0 < . • � 0 w Z --i z a O 0 — 3 Z H ��i►����.ie Z M � LL L , I a W W • , �, � • . • • J ,t , � 4• o V W LL y U) 0 > C . • 'S c h 4-. `r• o CL D z Z 0 =• % 0 P • , - N CL. F- . - .. 1— x : al : :2 °' -- • .J • (14 .) -J 2 D CL W Q "V • 0 o i 0.0= H W O " iC„ • .' • It cc a �' ♦c •'' 0 CD 0 s'is+si�� 0 N F ? co < a_ - co � J � c' 0 ( C ) a ° U) 2 F- . O c� W x z W ` X" U a C7 C a .1. W c") co oc D�t CO g3 Q rr CO U w� 0 w tY O ■ wO 0 H v) a Jr m z O I I { I ,i W 0w /J � _J \ a. u_ r ! = , i R Z z oo � J Y Y �( O CO ,--1 \wZ rr r /( Q o� = Q , 1, i U) _ -J W a) XQa rii / : z_ mz O 'n W l : : r / J 0 O o Li T} ! i i ,,' a m a -�+ i / I- 0 /,r Z o N U W 0 X A W , .., 0 J < x �; • • • • • * 4, ••• co _ a 2 i a (1) CO ,, �j It , / o w a �, • :0 d z / , ' ` ZZ a ; • C O • o o.2vA t _i W LL } 0 C7 : kr : Z m . __I 4 af- W� � =U•v o g 0. C7 W ' ,d,' • • ••.•�4`' cA a Z �� " rr • N • u) U z co ct i. `.. N �`� CL CL 0 �r'F -M . ' o Z W LL U O .� O W= Z O _.i -.J 0) oa CC z > d. W Cr) ¢ E 1 `` ' �- Z a J D'r LI _ J QU y\ $ \V'•,. S Q �'SWao W X y, U) > F-- Q O CO (1) W ;,i a N 1 CO ' � Z p W \\ `1 \, v `, y � a'�`;\ ( N1 P? J 0 0 v e 1` X O D 2 Z D _ = oo o . 5A '. • Z I- W . \\, ti mo C >Q * 1 s Q v p Z Z 0! y;` l r } 2 � �' � I ` //r` w - pa W W c % /% ' Ts w O ce < 1+ :' Cr p ap • 4 -I o X Oo0? • • r, ' OOZ Q w ./ W U ill p o ¢ a. j` f I /if / F- m 0 �W W ; .. W i J Z Y ; " .! 1 ' S2 W fn :74, i , a • l.o ,�; w a •� -S • 6' � a M J j //' o CO C C u' p; Cl s 1 W I '! ° O Z Q . Lj • • z 4 o ...1 _ t 4 p s// O DC7 _W.ti1 "s7 * �•Q W a l I / I I �Z ° v :v O F 0 •p: rl w m _ j �I , _, F- W Z % ,j n- OXC� E. � //if 0 W Z ��,�� , Q d. C7 a F- , . '. , t- < O U) (/) l X N W 1 1 TUFF -RIB 26 GA. GULF LOAD TABLE OVER 1x4 WOOD PURLINS COAST Buildings having a Roof Mean Height <_ 20' -0 "; Roof Slope: 2 "/12" -6 "112" Gable Roof Wind Speeds 110 -140 mph, Exp C, I = 1.0, based on FLORIDA BUILDING CODE 2007 TUFF -RIB 26 GA. FASTENER SPACING WIND SPEED ZONE ZONE FASTENER SUBSTRATE 110 120 130 140 ON CENTER ON CENTER ON CENTER ON CENTER SPACING SPACING SPACING SPACING ZONE 1 #9 -15 x 1 -1/2" 1x4 WOOD 24" 24" 24" 24" PURLINS ZONE 2 #9 -15 x 1 -1/2" 1x4 WOOD 24" 24" 24" 24" PURLINS ZONE 3 #9 x 1 - 1/2" 1X4 WOOD 12" 12" 12" 12" PURLINS 1) PANEL DESCRIPTION: TUFF RIB, MIN. 26 GA., 3 /" TALL RIB, 36" WIDTH. 2) PANEL FASTENER: #9 -15 x 1 -1/2" HWH W/ WASHER. 3) PANEL ROLLFORMER: MRS METAL ROLLFORMING SYSTEMS. 4) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: 109.25 PSF @ 24" O.C., 164.25 @ 12" O.C. BASED ON UL 580 /UL 1897 TESTING BY FORCE ENGINEERING TEST REPORT #117 -0062T -07D, E. 5) PLYWOOD DECKING: 1x4 WOOD PURLINS OVER MIN. 15/32" THICK PLYWOOD. MUST BE DESIGNED IN ACCORDANCE WITH FBC 2007. STANDARD PATTERN 1 9' CONTINUOUS coNoUS TAPE SEAL I < SIC FOR USE ON SLOPES + 9' I< 9' LESS TIEN 3:12 `\ ` -#9 -15 x 1 1/2' 1Y000GRIP , o s ttetttE . .s� C 1GE E. l ✓'' ZONE ., f257 .Q •• CE NT '" O, * 4111". F ja ~ .. No.44 . *' , . 0 • • STA e F ►• 4U Ridge Gable •• do , it �'`. 1j *.•.L ....• • fa ZONE 1 NOV 0 8 2008 -, 1- Note: Dimension (a) is defined as 10% of the minimum width of the building or 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be less than either 4% of the ZONE 3 Eave minimum width of the building or 3 feet.