Loading...
HomeMy WebLinkAbout09-9108 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780 -0020 9108 BUILDING PERMIT Permit Number: 9108 Address: 3951 COPELAND DR Permit Type: COMMERCIAL ZEPHYRHILLS, FL. Class of Work: NEW CONST /COMM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 24- 26 -21- 0000 - 00100 -0080 Improv. Cost: 310,000.00 °54g; �az._. z :_ 01 Date Issued: 5/14/2009 Name: WHEEL BLAST Total Fees: 9,140.21 Address: 3951 COPELAND DR Amount Paid: 9,140.21 ZEPHYRHILLS, FL. 33542 Date Paid: 5/14/2009 Phone: (813)715 -7117 Work Desc: 100 X 200 STEEL BUILDING rItr At!' 4 7: . �.s OWNER BUILDING FEE 1,665.00 SEWER C OMMERC 7,475.21 / P 0 C VVV ��L - /s 111 -134t Mi 4,4 get_ 9* i 9-09 FOOTER 2ND ROUGH PLUMB a MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE -METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE -SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to any one of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." L / i") air 41 , O R SIGNATURE PERMIT OFFI FR PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 0 p •r, ',% "fir s,r Z" W hibi ist i -_, i,,;,.4.,,,i-ceelvt.,,..1,., s.. '' 7..<' '., - 813- 715 -7117 VOICE 813- 780 -1771 FAX . May 13, 2009 To Whom it May Concern, I authorize Mr. Jeff Brown to pick up our building permit. He will have with him our check for $9140.21, made out to the City of Zephyrhills. Thank you for your help, . Michael Lynch President Wheelblast, Inc. State of r of tDA County of PA Sc-- 0 On this 13 day of 41 iti 2009, before me the undersigned notary public, personally appeared 11A tC l-114, L Ly IOC i known to me to be the person)s) whose name(s) is /are subscribed to the within instrument and acknowledged that he /she /they executed the same for the purposes therein contained. , . Notary Public Personally Known to me. " '•• LAWREWCELENIN r•, *: •• 1.1 MY COMMISSION # DD 678629 t EXPIRES: May 28, 2011 4, .. Bonded Thru Notary Put* Underwdbr 3951 Copeland Drive, Zephyrhills, Florida 33542 Jacqueline Boges From: , , RJ Keetch Sent: Wednesday, April 29, 2009 3:54 PM To: wheelblast @aol.com Cc: Todd Vandeberg; Jacqueline Boges Subject: Minutes /Approval Conditions Wheelblast Attachments: SPR Minutes04092009.docx Michael, I'm not sure if you received a copy of the minutes /approval conditions from the public hearing or not? Please see attached copy. Technically the way this was approved we're requiring that the landscaping be brought up to code. We won't hold you up on pulling building permits, but let's discuss sometime tomorrow if you're available. If you want to reference the landscape code requirements they're available on the City's web page at http: / /www.ci.zephyrhills.fl.us /Land 1227.asp . The code section is 7.06.00 RJ Keetch From: RJ Keetch Sent: Friday, April 10, 2009 4:50 PM To: Site Plan Committee; Keith Williams; mszi @verizon.net Subject: 4/09/09 Please see the attached SPRC meeting minutes. Disregard the previous attachment. RJ Keetch Planner, City of Zephyrhills Development Department (813) 780 -0000 x3535 rjkeetch(ii ci.zephyrhills.fLus 1 Bill Burgess From: Bill Burgess Sent: Thursday, April 09, 2009 10:29 AM To: wheelblast @aol.com Cc: RJ Keetch; Todd Vandeberg Subject: Sewer Connection Fee Mike as we discussed based on 30 total employees on an 8hr shift , Sewer Connection Fees would be a total of $7,475.21 1 W- , s • City of Zephyrhills Water and Sewer Impact Fee Calculation Land Use Type: Factory (A) No Showers Provided No. of Employees per 8hr Shift 30 Impact Fees For Type A Within City Limits Outside City Limits $ $ 2,979.86 Wastewater Collection System $ 4,791.61 $ 5,989.50 Wastewater Treatment Plant Capacity $ 2,683.60 $ 3,354.51 TOTAL $ Gr $ 12,323.86 (B) Showers Provided ' 75 ° ZI No. of Employees er 8hr Shift N per Impact Fees For Type B Within City Limits Outside City Limits Water Distribution System $ - $ - Wastewater Collection System $ - $ - Wastewater Treatment Plant Capacity $ - $ - TOTAL $ - $ - NOTE: Does not include industrial wastes. 813-780 -0020 City of Zephyrhills Permit Application Fax- 813 -780 -0021 Building Department G/ 0 Date Received / — 2p Th� ( (' : i Phone Contact for Permitting -- Owner's Name (, v ieG fb /1 t 2 ' - Owner Phone Number fi j 3 ''f /) r 7 // 7 Owner's Address J /CV COPe /4'r , i Owner Phone Numf p ° ' 4 A /3- "f p ? - 1 6; et) Fee Simple Titleholder Name WiCGla,f' / Owner Phone Number or' Fee Simple Titleholder Address �J JOB ADDRESS 3147 CA C /Q, -/J/ 1Z ,LA& LOT # SUBDIVISION PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD /ALT 1 I SIGN n MOVE 1 1 DEMOLISH INSTALL REPAIR PROPOSED USE n SFR 1 VI COMM 1 I OTHER I 1 TYPE OF CONSTRUCTION 1 1 BLOCK 1 1 FRAME 1.)<1 STEEL n OTHER DESCRIPTION OF WORK /t Z /� 0 X 00 /Ice/ / ./iZ./' BUILDING SIZE /00 400 SQ FOOTAGE Z 0 0.0 .0 HEIGHT Z3 / Z rr BUILDING $ 3 ie oo VALUATION OF TOTAL CONSTRUCTION 1 ELECTRICAL $ AMP SERVICE 1 1 PROGRESS ENERGY 1 I W.R.E.C. 1 1 PLUMBING Mgr M ( itA re ` I MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION Q��� t� !'i I 1� 1 GAS 1 1 ROOFING 1 1 SPECIALTY 1 1 OTHER %/ /0v C FINISHED FLOOR ELEVATIONS . 7-7, ' f/ FLOOD ZONE AREA 1 (YES 1 'NO - a• BUILDER URE / `� COMPANY 444 e- /� / / I Y/ N j FEE CURRENT 1 `ON 1 Address 1 3 /J -/ Core /-hd� t2 (.,• License # ELECTRICIAN COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y/ N I Address 1 License # I PLUMBER COMPANY SIGNATURE REGISTERED 1 Y / N I FEE CURRENT I Y/ N Address License # MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y/ N I Address License # OTHER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y/ N 1 Address 1 I License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R -O -W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions /large projects COMMERCIAL Attach (3) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-0-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. * ** *PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $5000) ** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades NC Fences (Plot/Survey /Footage) Driveways -Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has, hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division — Licensing Section at 727 -847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT /UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89 -07 and 90 -07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water /Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law— Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner ", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S /OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection - Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District - Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers - Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services /Environmental Health Unit - Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency- Asbestos abatement. Federal Aviation Authority- Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A ", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for Tots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the \ job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS AN YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER RECORDING YOUR NOTICE OF COMMENCEMENT. f , FLORIDA JURAT (F.S. 117.03) OWNER OR AGENT CONTRACTOR S scribed and swo to or a "rme. b fore me this Subscribed and swo�r j to (or affirmed befpre me this 5.� d q by �c G Who -are a `'� � a ave 4 Who is /are ersonall known to me or has /h a produced Who Is are personally known to me or ha�hav produced L - as identification. as identification. _ t / M e_ Notary Public (3)ci Notary Public JACQUELINE B E S C m • sioor ► Commission DD 621833 Commission Expires December 12, 2010 Commission DD 621833 „oF�F °�° P Bonded Thru Troy Fain Insurance 800-385-7019 'Z; ‘_Commission. Deuernber iC, 2010 Name of Notary typed, printed or stamped Name of Notary typed, p edFbr stfti ,Trot/ Fain Insurance g0- 385 -7019 From: Kerry Barnett <kbarnett@fire.zephyrhills.fl.us> To: Michael Lynch•< wheelblast @aol.com> Sent: Wed, 6 May 2,009 10:34 am Subject: RE: Michael, Thanks for the information. I will attempt to review it today. Kerry Barnett Fire Marshal, Zephyrhills Fire Rescue 813- 780 -0041 kbarnett(a�fire.zephyrhills.fl.us From: Michael Lynch [mailto:wheelblast @aol.com] Sent: Wednesday, May 06, 2009 10:18 AM To: Kerry Barnett Subject: Re: Kerry, Attached please find our code review for for Insect Deterent System (shed). Please do not hesitate to call if you have any questions. Michael Lynch WHEELBLAST INC 813 - 917 -1361 Original Message From: Kerry Barnett <kbarnett@fire.zephyrhills.fl.us> To: wheelblast @aol.com Sent: Tue, 5 May 2009 11:25 am My email is attached per our recent conversation. Please send the report that was discussed that could help with plan review. Kerry Barnett Fire Marshal, Zephyrhills Fire Rescue 813 - 780 -0041 kbarnett@fire.zephyrhills.fl.us Big savings on Dell's most popular laptops. Now starting at $449! A Good Credit Score is 700 or Above. See yours in just 2 easy steps! 2 Jacqueline Boges From: Bill Burgess Sent: • Wednesday, May 13, 2009 2:25 PM To: Jacqueline Boges Subject: FW: Building permit for Wheel blast Attachments: wheelblast spray building.doc Jackie can you please file with the permit and call Mike Lynch 813 917 -1361 of Wheel blast and let them know they can get their permit if ready. Thanks Bill From: Kerry Barnett Sent: Tuesday, May 12, 2009 5:42 PM To: Michael Lynch Cc: Bill Burgess Subject: RE: Building permit for Wheelblast Michael, After reviewing the information at hand, plans and the different codes, as well as, talking with other fire marshals the items listed will be required. If you feel differently, you shall support your reasoning based on code. The language shall be forwarded to me to review. Also at this time, I will allow the concrete slab to be poured and building to be erected. However, the building will not be used until all comments attached are addressed. Should the building be used without authorization, fees and possible legal action will be implemented. I have forwarded a copy of this to the Building Official. Kerry Barnett Fire Marshal, Zephyrhills Fire Rescue 813 -780 -0041 kbarnett@fire.zephyrhills.fl.us From: Michael Lynch [mailto:wheelblast @aol.com] Sent: Monday, May 11, 2009 8:12 PM To: Kerry Barnett; dcook @stcsafety.com Subject: Building permit for Wheelblast Kerry, This email is to request that we be able to move forward with the basic construction of the building on our property as detailed on the drawings. This request is being made so that construction can run concurrent with our finalizing our safety review and implementation prior to facility start up. Wheelblast and our safety team will conduct our HAZOP review on Friday and resolve the issues to your satisfaction. Thank you again for your assistance in getting this project moving forward so we can satisfy our clients in this difficult market. Michael Lynch WHEELBLAST INC 813 -917 -1361 Original Message 1 Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (813) 780 -0041 Kerry Barnett Fax (813) 780 -0044 E -mail: kbarnett@fire.zephyrhills.fl.us Plan Review #: 09 -034 Project: Metal Frame Building for Flammable Spray Applications Number of Pages: 29 (2 sections) Date: May 11, 2009 I have received and reviewed the plans for the construction of a structure used for flammable spray application operations located at 3951 Copeland Dr. and have not approved this project to move on without the following items being addressed. Fees will be withheld until a revision is submitted. Should anyone have any questions, please do not hesitate to contact the Fire MarshaI's office. 1. This building was reviewed under NFPA 33, 2007 edition. This standard applies to the spray application of flammable or combustible materials, as herein defined, either continuously or intermittently by any of the following: (1) compressed air atomization, (2) airless or hydraulic atomization, (3) Electrostatic application methods or (4) other means of atomized application. This structure utilizes (3). The building is a partially enclosed structure (roof and semi enclosed walls on 2 sides) Therefore defines this area as an unenclosed spray area (NFPA 33, Chapter 3.3.1.3.1) There is no exception in NFPA stating this open shed design is equivalent to the outdoors. 2. 1.1.4 of NFPA 33 refers to makes a statement that it does not apply to application processes that are conducted outdoor, however when you read the information under that section in the appendix it refers to the spraying of a building or similar item in the outdoor. 3. NFPA 33, Chapter 1.3 states chapters 4 through 10 and Chapter 18 shall apply to all spray application processes which includes, construction, electrical, ventilation, storage & handling, protection, operation & maintenance and training. 4. Once the materials are laid out to be sprayed, there shall be a 3' clear space maintained on all sides and through the centers to provide for an unobstructed and safe egress. NFPA 33, Chapter 5.3.2 5. Chapter 7.2 states each spray area shall be provided with mechanical ventilation. It shall be designed in accordance to NFPA 91. 6. Electrical shall be in accordance to chapter 7 ofNFPA 33 and NFPA 70. 7. Fire protection shall be in accordance with chapter 9 ofNFPA 33. 2 8. , Maintenance procedures shall be established for maintaining all spray equipment, including air hoses, any ventilation equipment, and fire protection equipment. Approved waste containers shall be provided in designated locations for the disposal of impregnated (with sprayed material) rags or waste. Chapter 10 of NFPA 33. 9. No smoking signs shall be posted at all spray areas and mixing Iocations. Signs shall state "NO SMOKING OR OPEN FLAMES" in large letters on contrasting color background. Chapter 10 of NFPA 33 10. No hot work of any kind is allowed in or adjacent to the spray area without authorized approval from the AHJ. Chapter 10 of NFPA 33 11. All personnel involved in the spraying application process shall be trained in potential safety and health hazards, operational, maintenance, and emergency procedures required, and importance of constant operator awareness. They also shall be instructed in proper use, maintenance and storage of all emergency, safety or personal protective equipment required. All training shall be documented with name of person(s) attending training along with type of training and date. This information shall be provided to the AHJ prior to construction final. 12. The interior surfaces shall be smooth, designed and installed to prevent pockets that can trap residues, and designed to facilitate ventilation and cleaning. 13. When netting is installed over unenclosed openings, the building becomes enclosed and shall comply with NFPA 101, Chapter 7, Life Safety Code, which includes but not limited to, exit and emergency lighting and type of locking hardware allowed. 14, Portable fire extinguishers shall be in accordance with NFPA 10. NFPA 33 states that the hazard classification is "extra high ", therefore Chapter 6 of NFPA 10 states extinguisher type shall be a minimum of 40 -B provided every 30 feet or 80 -B provided every 50 feet. i f# ✓ KERR ` ' '4- TT, FIRE MARSHAL ***Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. 44,04d' 21-0 9 t� ,___ �a ?.I►t7 -s ,/(, i s City of Z ephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: WA ediks v Date Received: 1 -27-d i Site: 39c 5 5(x i Permit Type: C 5 /lO) 2od 3-Ved Skid Approved w /no comments Approved w /the below comments: k Denied w /the below comments: ❑ • I ) W et Ae GA 1 ri p tut be 4 7 4 7c. 21 if t» dose, +0 0 4 Iti p Ct. Tf od ck not I._ live- Idu ili ituttcl 1 Pit, Os c -a Coo,,, i--) • , • 1 z SiaLly (, o o/ W 111 A / Al • I — r1 / 0 rA 1 . -.P`C, S e 5 1 1 : �` -f l rJ . 2 1? h i4 ( ell 04 SI a. 1/ be Acef ,i ) 3 /VI w.e Ids sila f 6e IA r C /(of 6. 0/) /nd,ere r1 dP,, f' s ci if ov) av e i y q ,i/ r-e er b 54(1/ (' 9 f /494 i-o Me 64 pie This comment s eet all be kept with the permit and/or plans. 19 1- / / Kal in Switzer ans Examiner Date S/ act Homeowner • • equired when comments are present) WHEELBLAST, INC. 44224 City of Zephyrhills 5/13/2009 9,140.21 Bank of America Chec Permit 9,140.21 Prepared by and after recording . return to: Josie Turner ' Bank of America, N.A. Doc Retention — GCF MO 1- 800 -08 -11 800 Market Street, 8 Floor St. Louis, MO 63101 -2510 Permit No. Tax Folio No. NOTICE OF COMMENCEMENT The undersigned hereby gives notice that improvement will be made to certain real property and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: this s . ace reserved for the recorder 1. Legal Description of Property: Lot Block Unit # Bldg # ❑ Lengthy legal attached Subdivision / Condominium: Street Address if available: 3951 Copeland Dr, Zephyrhills, FL 33542 - 8403 2. General description of Improvement: 20,000 SF Steel Building 3. a. Owner name & address: Wheelblast, Inc. b. Interest in property: Fee Simple c. Name & address of fee simple Wheelblast, Inc., 3951 Copeland Dr, Zephyrhills, FL 33542 Title holder (if other than Owner): 4. a.. Contractor name & address: Canco General Contractors, Inc., 2502 Frontage Park Place, Plant City, FL 33563 b. Contractor's phone number: 813 - 750 - 1222 5. a. Surety name and address: N/A b. Surety's phone number: N/A c. Amount of bond $ N/A 6. a. Lender name & address Bank of America, N.A., 9000 Southside Blvd #100, Jacksonville, FL 32256 b. Lender's phone number: 7 a. Persons within the State of Fbrida designated by Owner upon whom notices or other documents may be served provided by Section 713.13(1)(a)7., Florida Statutes: Name: Bank of America, N.A. Address: 9000 Southside Blvd #100, Jacksonville, FL 32256 b. Phone Number: 8. a. In addition to himself or herself, the Owner designates: to receive a copy of Lienor's Notice per Section 713.13(1)(b), Florida b. Phone number of person or entity designated by owner: 9. Expiration date of notice of commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMECNCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Signature(s) of Owner(s) or Owner(s)' Authorized Officer /Director /Partner/Manager Wheelblast, Inc. Wheelblast, Inc. By �10r By Print Name Michael B Lynch Print Naran C. Purvear Title /Office President Title /Office Vice President STATE OF FLORIDA COUNTY OF PASCO T `H The foregoing instrument was acknowledged before me this L day of May, 2009 By chael B. Lynch and Susan C. Puryear co I rvidually, or x as Officers for Wheelblast, Inc. , a Florida Corporation Personally known, or ❑ produced the following type of identification: I i0 .. Signature of Notary Public: V._ .#10 .., , / , / Print Name: /� V f� LE v/ iF (SEAL) LAWRENCE .4: • MY COMMISSION # LEVI 6 78629 VERIFICATION PURSUANT TO SECTION 92.525. FLORIDA STATUTES ._ ' -= EXPIRES: May 28, 2011 f f ( 9ardad Thru • Nota Pu Underwriters Under penalties of perjury, I declare that I have read the foregoing and That the facts stated in it are true, to the best of my knowledge and belief. Signature(s) of Owner(s) or Owner(s)' Aut ' d Officer /Director /Partner/Manager who signed above: /r By Michael B. , Preside B y us+ . Pu ea 6 V Presi enQ t -sr—,----401 Ref: 1000128818 - K: \Non Real Estate Team \HotDocs Loan Documents \Turner, Josie \...G C F LOANS \Wheelblast, Inc. = Pkg #31609 \GCF 31609 Notice of Commencement.doc Date: March 25, 2009 To: City Manager, Mayor & SPR Committee From: RJ Keetch RE: Site Plan Review Committee Attendance: David Shears, Shane Le Blanc, David Henderson, Steve Spina, Bill Burgess, RJ Keetch, Rick Moore, Keith Williams 1. Wheelblast (SPR- 02 -09) — Site Plan Review to add an additional structure to an existing manufacturing business located at 3951 Copeland Drive. The applicant, Mr. Mike Lynch, presented site plans showing the location of a proposed 20,000 square foot, 45 foot high steel and canvas building. The applicant described the nature of their business and their desire to construct a structure to protect their manufacturing process from the spring "love bugs ". The Site Plan Review Committee recommended approval with the following conditions: i. Verify proposed size (length, width and height) of structure and submit final site plans to Development Services. Provide at least two site plans for stamped approval; ii. Provide an up to date SWFWMD permit and/or letter from the engineer verifying that current proposed activities are permitted and/or will not require an additional permit; iii. Comply with the 2007 Building Code (including the 110 mph wind load); iv. Coordinate with fire Department (Keith Williams / Kerry Barnett); v. Coordinate with Utilities Department (David Henderson) regarding utilities / septic. The applicant is advised that City Sewer is available; vi. Landscape buffer w/ water supply needs to be brought up to code on site (western boundary, Tucker Road & Copeland Drive. Applicant to provide a landscape plan to Development Services; vii. Trina Sweet will coordinate with LPA for height compliance of proposed structure with City Airport zoning ordinance. 2. Saturday Nite Cruise — Special Event Application (Saturday April 25, 2009 & the fourth Saturday night of the week for one year). Main Street will host a car show on Saturday April 25, 2009 (4 pm to 9pm) and every fourth Saturday of the month for a period of one year. As with previous events the show will take place on 5 Avenue between 7 and 10 Street. Brenda Welcher, executive director of the Main Street program presented the application. At the last SPR meeting Mr. Spina asked Ms. Welcher to survey the businesses downtown. The ten businesses • that responded to the survey are all in favor of a car show once a month downtown. Two representatives from the Pasco Roadrunners club were also present at the meeting. Mr. Le Blanc thanked them for the "great job cleaning up" and promised to coordinate with them for the upcoming events. The SPR Committee recommended approval. 813- 780 -0020 City of Zephyrhills Permit Application Building Department 93 - i tij a Date Received -2.4-o9 phone Contact for Permitting – VI / $ Owner's Name A/4e /b/.f f ....27/..- Owner Phone Number ') 3 -- 'J /Jam- 1/7 • 3/.5 / C o pe /arc, j�,- , 04– 0 813- 917 - 13o! ` a Owner's Address O wner Phone Num Fee Simple Titleholder Name' Lace J %.r . Z /'- Owner Phone Number l Fee Simple Titleholder Address . JOB ADDRESS 3 4',,,,,i%' n /S / LPC ,!/'� i•vt'- LOT# SUBDIVISION PARCEL ID#( (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ( ADD /ALT n SIGN n MOVE n DEMOLISH INSTALL REPAIR PROPOSED USE n SFR I SZI COMM n OTHER I I TYPE OF CONSTRUCTION n BLOCK I FRAME /� AME STEEL n OTHER I 1 ) DESCRIPTION OF WORK / 0 0 X Z 00 / ? ✓e.,/ ►,e j BUILDING SIZE 1 /00 ,j! Z 00 SO FOOTAGE 2 0 ODo HEIGHT' Z / Z rr � 1/41 BUILDING $ 3 he e oD VALUATION OF TOTAL CONSTRUCTION n ELECTRICAL 11111111111111M AMP SERVICE I PROGRESS ENERGY n W.R.E.C. ;fit• ,, I� PLUMBING'.; I MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION 4 1 ...,----- 1-1 n GAS 1 ROOFING 1 SPECIALTY n OTHER c/ FINISHED FLOOR ELEVATIONS 77 s - r f/ FLOOD ZONE AREA nYES nNo BUILDER - : ,..44f p 7 COMPANY K//lC4./47 �"/c– SIGNATURE /� a n 7 • REGISTERED I Y/ N I FEE CURRENT I Y/ N I Address I 3'9r/ C,e %,ads ".4. 1 License# ELECTRICIAN COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y/ N I Address 1 License # PLUMBER COMPANY ' SIGNATURE REGISTERED I Y/ N 1 FEE CURRENT I Y/ N 1 Address I License# MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y/ N I Address 1 License # OTHER COMPANY SIGNATURE REGISTERED I Y/ N 1 FEE CURRENT I Y/ N I Address I 1 License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R -O -W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (3) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R -O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilltles_8 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. _ ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over 35000) •• Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades NC Fences (Plot/Survey /Footage) Driveways -Not over Counter if on public roadways..needs ROW NO lecitk — SYy 1 y$ • Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (813) 780 -0041 Kerry Barnett Fax (813) 780 -0044 E -mail: kbarnett@fire.zephyrhills.fl.us Plan Review #: 09 -0041 Project: Revision for Spray Application Structure Number of Pages: letter format (3) June 2, 2009 I have received and reviewed the supplemental plan from our meeting for the flammable spray application structure located at 3951 Copeland Dr. This project will be allowed to move forward with comments made below. Paying for permit, contractor acknowledges complying with the following items below. Be advised no revision fees were charged. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. 1. Operation and maintenance procedures will be shown to the Fire Marshal prior to CO. 2. Training conducted for employees shall be shown to Fire Marshal prior to CO. 3. Monitoring shall be conducted periodically (several times a year or when the type of flammable spray is changed) to verify vapors do not exceed the 25% of the lower flammable limit. Inspections Required: 1. Final KE • :.f 4 TT, FIRE MARSHAL ***Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non- compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Fire Chief Keith'Willianis Bus (813)780 -0041 Fax (813)780 -0044 • FIRE SERVICE USER FEES Occupancy No.: Plan No.: 09-- C3�f/ Contractor: i..i • .il,. Business Name: /, �6/.4;Sd' Billing Address: •e_ r 1���W! Business Address: 5W) Cr -4 - -1- ' Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES _ PERMIT FEE — FALSE ALARM FEE II Site Plan N/C 1 Annual N/C _ Sprinkler $50 _ 1st Alarm N/C 1 Multi Family /Commercial 06 sf J 1st Re- inspection N/C _ Standpipes 550 _ 2nd Alarm N/C inimum Charge 525.00 , 2nd Re- inspection $100 _ Fire Pump $50 — 3rd Alarm N/C Ian Revisions, 3rd Re- inspection $250 — Hoods 550 4th Alarm — 5100 4th Re Inspection $500 Fire Alarm 550 5th Alarm 5150 SPRINKLER SYSTEMS (Business closed until _ LP Gas 550 — 6th Alarm $200 R 0 - 25 Heads $50 violations corrected) _ Natural Gas $50 NON COMPLIANCE $150 26 plus Heads $100 SPRINKLER SYSTEMS _Fuel Tanks per rank $50 STANDPIPE SYSTEM Hydro Undergrounds 545 _ Sparklers 5100 ri Per Riser 550 Hydrostatic Test 565 per system ` Fire Works 5500 FIRE PUMP Acceptance Test $45 per system _ Camp Fire $25 0 Per Pump 5100 Hydrant Flow $75 _ Controlled Bum $100 FIRE ALARM SYSTEM Hood/Duct 550 ^ — _ 0 - 25 Devices $50 FIRE ALARM SYSTEM _ Place of Assembly 550 Annual _ 26 plus Devices 5100 System Acceptance 550 _ Fire Protection 525 SUPPRESSION SYSTEMS Recall Acceptance $50 _ Flammable Application 550 Annual Wet 550 _ OTHER _ Waste Tire Storage $50 Annual Dry 550 _ Are Wall/Smoke Wall $15 p er wall _ Generator < KW 5100 CO2 $50 _ LP Gas $25 per tank _ Generator >30 KW 150 Other $50 _ Natural Gas $25 per system — Bio-Hazard Waste $100 Annual KITCHEN EXHAUST _ Fumigation Tenting 550 0 Hood/Ducts $50 _ Tent 10x10' or greater $15 p er tent _ Torch Pot/Applied 550 ' OTHER _ Fire Pump $45 _ Haz. Materials $100 Annual LP Installation per tank $50 _ Fire Suppression 530 Fuel Tank Installation 550 System Acceptance (Per Tank) $50 Ex B haust Hood/Duct $30 El Natural Gas Installation $50 Re DBL (Per System) (other than annual) 11 Spray Booth 550 ❑ Inspection scheduled DBL and cancelled less than _ 24 hours _ Construction Insp. N/C ■ Emergency Vehicle Act $50 FALSE ALARM PLANS TOTAL r ; INSPECTION TOTAL PERMIT TOTAL TOTAL d GRAND TOTAL I / I - 1 Comments: Date: i/2 P, InsA / i ce.# .1c rte Whe : Inc • .• 813 - 715 -7117 VOICE 813 - 780 -1771 FAX TRANSMITTAL SHEET TO: FROM: Zephyrhills Building Department Michael B. Lynch COMPANY: DATE: City of Zephyrhills MAY 28, 2009 FAX NUMBER: TOTAL NO. OF PAGES INCLUDING COVER: PHONE NUMBER: SENDER'S REFERENCE NUMBER: 813- 780 -0020 RE: Permit # 9108 ❑ URGENT X FOR REVIEW ❑ PLEASE COMMENT ❑ PLEASE REPLY X FOR APPROVAL Attached please find 3 sets of documentation for review for the Life and Safety Plans of the Insect Control Spray Structure. Attachments: (3 copies of each) Supplemental Plan Submittal Cut sheet of Polytuf Brands CG -2 Containment Fabric 3951 COPELAND DRIVE ZEPHYRHILLS, FLORIDA 33542 MRS'- 26- 2009(TUE) 14.12 FH5 (FAX )863 534 1170 P. 0011002 ' ` ` I ' Q lest .Inc. • ij X341' ' Re: Wheelblast, Inc Supplemental Plan Submittal Below is supplemental information and covenants for the construction and operation of a canopy designed to control insects to be used for the spray application of flammable or combustible materials onto non - combustible objects utilizing airless application technology at 3951 Copeland Drive, Zephyrhitla, Florida. Should anyone have any questions, please do not hesitate to contact Mike Lynch, President, Wheelblast, Inc. 1. The Wheelblast operation is not a typical spray finishing operation in that the process does not produce vapors that exceed twenty -five (25) percent of the lower flammable limit due to the airless spray technology, unconfined spray area of over three - hundred- seventy thousand (370,000) cubic feet, and natural atmospheric dilution. Data collected to date on the current alike outdoor operations have yielded no detectable combustible emissions as close as one (1) foot from the spray nozzle. An alr sampling protocol designed to establish that the spray process within the canopy does not produce vapors that exceed twenty -five (25) percent of the lower flammable limit shall and Implemented immediately upon commencing operations. The air sampling protocol shall follow the criteria of the American Industrial Hygiene Association and be designed to provide a confidence interval that vapors that exceed twenty -five (25) percent of the lower flammable limit. Periodic monitoring Intervals shall be established based upon the initial survey data to assure that the confidence Interval 18 maintained. The air sampling protocol and data shall be available to the Authority Having Jurisdiction at all times. 2. The canopy shall be of open type design with at least three - quarters (3/4) of the structure perimeter shall open to the atmosphere or protected by fire retardant insect protection products that restrict ventilation to not less than 400 feet per minute. The canopy shall be provided with a standard ridge vent traversing the entire length of the canopy. Mechanical dilution ventilation shall be provided to supplement the natural ventilation if Indicated by the air sampling protocol described above. The assumption, based on existing data, Is that vapors that will never approach twenty - five (25) percent of the lower flammable limit that would require supplemental mechanical ventilation. 3. A three (3) foot clear space shall be maintained on all sides and through the centers when objects are laid out to be sprayed to provide for an unobstructed and safe egress. Length of materials will dictate vertical or horizontal layout within the canopy in a manner to ensure aisles are available and maintained. In addition, a center aisle will be continuously maintained of approximately eight (8) feet in width to facilitate access 4, No motorized for employees m to ial handling equipment will be operated at any time with: R�vl� ICS canopy while spray activities are being conducted. Detailed proce• l • _ • , ' - developed and all personnel trained In these procedures prioric -'• n - of the canopy spray process. .'� Ott ,% / j,I® / 5. No electrical equipment installation is planned within or t• " - = • • • ray area. This eliminates a potential spark producing ' Oast . our.- 1 0 electrical power from external sources shall be allowed withi Aced" cent to the canopy without execution of the Wheelbiast Hot Work penrit pr cess. Wheetblast, Inc. Page 1 of 2 5126/2009 MR9 26- 2009(TUE) 14: 12 FH5 (FRX)863 534 1170 P. 002/002 . •11, • e lj 0 • • 6. Approved waste containers shall be provided In designated locations for the disposal of rags or waste impregnated with sprayed material. 7. Operation and maintenance procedures including maintaining spray equipment, air hoses, and fire protection equipment will be established prior to Initial operation of the canopy. 8. All personnel involved in the spraying application process shall be trained in potential safety and health hazards, operational, maintenance, and emergency procedures required, and importance of constant operator awareness. They also shall be Instructed In proper use, maintenance and storage of all emergency, safety or personal protective equipment required. All training shall be documented with name of person(s) attending training along with type of training and date. This information shall be provided to the Authority Having Jurisdiction prior to initial operation. 9. No smoking signs shall be posted at all spray areas and mixing locations. Signs shall state "NO SMOKING OR OPEN FLAMES" in large letters on contrasting Dolor background, 10. No Hot Work of any kind is allowed within or adjacent to the canopy spray area without executing the Wheelblast Hot Work Permit process and authorized approval from the Authority Having Jurisdiction. 11. The canopy shall comply with NFPA 101, Life Safety Code, with respect to but not limited to exit numbers, marking, and door locking hardware. Exits travel will be limited to a maximum of seventy-five (75) feet, identified by self luminescent signs, and doors equipped with panic typed hardware if equipped with latches. The active use of the building will be limited to daytime activities and natural lighting will be available from translucent panels on the canopy when occupied negating the need for emergency lighting. 12. The canopy structural materials are non - combustible, the objects to be sprayed are non - combustible, and the insect protection products are fire retardant per NFPA 701, Standard Methods of Fire Tests for Flame Propagation of Textiles and Films. Fire protection shall be provided by 10 pound 4A:8013C portable fire extinguishers placed on 25' centers along the sides of the 200 foot canopy span. Additional fire extinguishers will be provided as needed. 13. All pertinent safety, operating procedure, training, permit, sampling documents shall be readily available to the Authority Having Jurisdiction at any time Mike Lynch David Cook CSP CHMM President Vice President of Consultation Programs Wheelblast, Inc. Safety Training and Consulting Inc. Wheelblast, Inc. Page 2 of 2 525/2009 p .. y tuf Toll Free: (888) 765 -9883 • (330) 773 -0184 • Fax: (330) 773 -0390 • E -mail: sales @polytuf.com rands,Inc. P.O. Box 3079 — Cuyahoga Falls, OH 44223 www.polytuf.com CG -2 4.72 oz. Polypropylene White MESH 85% Containment Fabric Fabric Specifications: Fiber Content: 100% Polypropylene Thread Count (per inch): 20 x 20 Shade Factor 48% Weight (coated): 4.72 oz. /yd2. Tensile Strength (ASTM D- 5034 -5 I Grab Method):Warp: 337 lbf Fill: 337 lbf Elongation (ASTM D -4632 I Grab Method) Warp: 17% Fill: 17% Tear Strength (ASTM D -2261 I Trap Method): Warp: 78 lbf Fill: 68 lbf Burst Strength (ASTM D -3786 I Mullen): 409 plbs /in2 Puncture Strength (ASTM D -4833 Modified) 123.6 lbs Air Flow: 312 cfm Standard color: White This material is an 4.72 oz. polypropylene that is a woven Mesh with an 85% permissible air flow rating. This material meets the SSPC Guide 6 for class 4 containment under Containment System (5.3 of Guide) This product meets the specification NFPA -701 for flame resistance. The coating on this product meets the specification NFPA -701 for flame resistance governed by: The National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02169 -7471 Phone: 617- 770 -3000 Fax: 617 -70 -0700 ww .n tpa.or � The results of NFPA 701 are used to assess the propagation of flame of various textiles and films under specified fire conditions. The test methods included apply to curtains, window shades, draperies, table linens, textile wall hangings as well as to fabrics used in the assembly of awnings, tents, tarps and other similar architectural fabric structures and banners. Specific information is provided on the types of test apparatus, calibration of equipment, conditioning of specimens and testing and cleaning procedures. NFPA 701 (Small Scale) testing measures the ignition resistance of a fabric after it is exposed to a flame for 12 seconds. The flame, char length, and flaming residue are recorded. The fabric will pass the test if all samples meet the following criteria: 1. An after flame of less than 2.0 seconds 2. A char length of less than 6.5" 3. The specimen does not continue to flame after reaching the floor of the test chamber Fabric certified as flame retardant is certified to have been tested and passed the NFPA 701 test. signmummilliiiii llll Rcpt:1244636 731% 0.00 Rcc: 18.80 • 22/09 IT: p 00 Clerk 1 COVERSHEET Please keep this cover sheet with the document through all distribution and communication. DO NOT DISCARD! PAULA S O'NEIL, PASCO CLERK & COMPTROLLER 1000128818 06OR B 1P6 o 14 35 Borrower Name: Wheelblast, I nc. Document: Notice of Commencement GCF Package: 31609 Guarantor Name: Document Type: Real Estate - Oth Line of Business: Centralized Credit Delivery/ CCD System of Record: AFSEAST Bank Number: 21 Obligor Number: 0003380768 PLEASE RETURN THIS DOCUMENT TO BANK OF AMERICA Ref 1000125818 - K:Noe Red Fitme Team \RotDon Lan Mammas \ Turner, Jou& .0 C F WANSWheelb t, Inc . - Pkg #31609\OCF_31609Notice of Commencement doe 4. Prepared by and after recording return to: Josie Turner Bank of Americo, N.A. IA K e c T1't T \ OR BK 8090 PO 1436 Doc Retention — GCF p9 ) 01- 800 -08 r- ,9 2 of 2 801 Market Street, et, 8 Floor 1 J J (0 St. Louis, MO 63101 -2510 (e) s+ L0 '(S M 0 Permit No. 1 f Tax x Folio No. iCJ I t0 NOTICE OF COMMENCEMENT The undersigned hereby gives notice that improvement will be made to certain real property and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: this s, ace reserved for the recorder I. Legal Description of Property: Lot Block Unit # Bldg # ❑ Lengthy legal attached Subdivision / Condominium: Street Address if available: 3951 Copeland Dr, Zephyrhills, FL 335424403 2. General description of Improvement: 20,000 SF Steel Building 3. a. Owner name & address: Wheelblast, Inc. b. Interest in property: Fee Simple c. Name & address of fee simple Wheelblast, Inc., 3951 Copeland Dr, Zephyrhills, FL 33542 Title holder (if other than Owner): 4. a.. Contractor name & address: Canco General Contractors, Inc., 2502 Frontage Park Place, Plant City, FL 33563 b. Contractor's phone number: 813 -750 -1222 5. a. Surety name and address: N/A b. Surety's phone number. N/A c. Amount of bond S N/A 6. a. Lender name & address Bank of America, N.A., 9000 Southside Blvd #100, Jacksonville, FL 32256 b. Lender's phone number: 7 a. Persons within the State of Fbrida designated by Owner upon whom notices or other documents may be served provided by Section 713.13(1x0)7., Florida Statutes: Name: - Bank of America, N.A. Address: 9000 Southside Blvd #100, Jacksonville, FL 32256 b. Phone Number: 8. a. In addition to himself or herself, the Owner designates: to receive a copy of Lienor's Notice per Section 713.13(1)(b), Florida b. Phone number of person or entity designated by owner: 9. Expiration date of notice of commencement: (the expiration date is 1 year from the date of recording unless adifferent date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMECNCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Signature(s) of Owner(s) or Owner(s)' Authorized Officer/Director/Penner/Manager Wheelblast, Inc. Wheelblast, Inc. By B Print Name 'duel B. Lvuch Print Na a C. Purvear Title/Office Prestent Title/0 Vice President STATE OF FLORIDA COUNTY OF PASCO �} The foregoing instrument was acknowledged before me this 1(4 t ' day of May, 2009 • By Mic ael B. Lynch and Susan C. Puryear Int>dually, or x as Officers for Wheelblast, Inc. , a Florida Corporation Personalty known, or ❑ produced the following type of identification: ,f Signature of Notary Public: t• 1 » 1 fh,LJI 07/ LEY Print Name: LE V / - (SEAL) lABIENCEIEYN VERIFICATION PURSUANT TO SECTION 92.525. FLORIDA STATUTES Ni PAY CAAiA ICN EXPIRES. May 28, 2011 Under allies of award IlinNdry PYouderedm pen perjury, I declare that I have read the foregoing and That the facts stated in it are true, to the best of my knowledge and belief. Signature(s) of Owners) or Owner(s)' Authorized Officer /Director /Partner/Manager who signed above: B y B i . dent Ref: 1000128818 - K: Non Real Rowe Team \NuiDou Lon, Documents \Turner, Joie \ ..0 C F LOANS IWheelNea, lee. = Ping 83160910CF_31609 Notice ofCammaeennoldoc 18-Jun-2009 04:56 PM Bank of America 727 - 532.2820 2/2 . P,repaWd by and eller recording roam to. losie'hmer Sank of Mama, N.A. r n� � hdD! t00 Os�- f i a .K tsc TNT'. OR gK 8090 PG 1 436 600 Market Strew, S` Floor P. . Oki O� fe 2 � of 2 BL Lour, M0 01014510 (e) l�ok is M 0 Permit No Tba Folio N. &p 1G 4 NOTICE OF COMMENCEMENT s lue The undersigned hereby are 00110. Ihat unprovemont will be made to cattalo reel property and m aoaordanaswith Chapter 713, Plodda Statute, dui Ibt lowing tnfbrmiUon it provided to thn Nato of Commatramnent 1 awa maenad Oar m. rot 1 Legal Pesoriptron of Property Lot Block unit ff eta R p Lan Subdlv2stert /Condonnmum I Lengthy Ir ;d atmehcd Street Add= itavniabIR 3931 CepnIand Dr, Zephyrhllle, FL 333424400 I General dettrrptton ofImprovement 30,000 SF Steal Building 3 a. Owner note Madden,. Wheetblay Ina b Interest rn mow. Pee P n Name St lddrese of de merle Whaotbla 3933 Copdead Dr, ZephyrhIlle, FL 32342 TEN holler 0folherthan Owner) 4 a Contactor nanra A whims. Canto General Coolraeton, Inc, 11102 Frontage Perlt Place, Plat City, FL, 33563 b Contractor's phone number ei3.750.1222 3 a Surerynune and admit WA b Sardy'e phone number NFA e. Amount of bond S N/A 6 a. Lends, now de ddrau Dank of America, N.A. 9000 Southold* Ulvd 0100, Jutted bell le, F1,32206 b Lender'aphoneUmber f e, Amon within the Meta of endedeny, ated byOwnerrrpenwhamhekeaearother dominantsmayboservedprovidedbySeaton 713 ,4(1)(.)7, Ronda Amen Ni • Batik of Am.11u N.A. Address 9000 Soulhalde Blvd 0100,daaluouvtlt , FL 32256 b Phone Number. 9 o Inadd, twnro bluff or harm; the Owner dungeon 1.Neav e aor'et4vmceper ton 71313(1) ), ea b Phone numberofpe:soner entity dummied by owner 9 5aplNUon doe ofnotleoofeommrnamene (tbs mrprmtton dale N 1 year Rom Ole de od f tsmrdmg tiniest ad ihrent dale rt spenAed) WARNINO TO ON7dBBi ANy PAYMENTS MADE EYTHE OWNER AFTSit THE 3 IPAT10)4 0FTN2NOT or COMMIDICe m r ARE PAAYIIN RO TyANO7IC80900NMMICNCk 'M FLORIDA 5NTMUM*O RRECOR °,AN�DPOOTI JOB seem berme The Rear IN3P0JLT10N 19 YOU MVO TO OBTAIN 9INANC040, CONSULT WITH YOUR LII MISRORANATTOINIY BEFORE COMMN$CINO WORK OR M:CORPINO YOUR NOTES OPCOMMENOL'M K StualiuMefOoii o1errDvw e de) ' Awkward OOtrmr.atern'adnniMwp,r W+.aret, Ira 1YiMNur, kW By maiPema 6 th � nl NI Title/Oisee pn,Me. fled° Vienewid.,t 6'TATDOPFLORMA COUNTYo' PASCO The Reticles IN1mmeat was aakaoti iodaed wore raw 1210 1'1 day o May, 2009 • BY�M 18 Laub and Math C. rdryear lie)M ally, et 0 la =on 2br WMdtl Ow . a FInoida tatlr Cooperation ono iluY kaova ar D produd ti Mewing yyaorgemetktne6 3r5r.rue otNatayreline M a Peat Name µ41K0 LEVI,' caeAta -- t uICOID N i na smacatabuttaumantrama M a� Under phoebe* of - I mfl p aNq 1declarethatIhavereadgipM s led }:. r.rers0 The the Ikea dated pt R a . mute the bat army kadad= sand beWIer ..— Sgamue(gaf0wags) Own a'Au mud Offku /Doxioat'4eNMInaawwho mined auye °y M ea. PER Id ti Mlle Pal ao.Ta. arm.. t. snows.m,aw,2,.w, - tee aiuonoctinauwaa.raa.,.asa Jacqueline Boges From: RJ Keetch U Sent: - -• Monday, June 22, 2009 1:37 PM To: Jacqueline Boges Subject: RE: Approval conditions for Wheelblast From: RJ Keetch Sent: Monday, June 22, 2009 1:19 PM To: Todd Vandeberg Subject: RE: Approval conditions for Wheelblast Todd, I think we're good on these except for #2. I have a call into their engineer to find out the status of their SWFWMD permit. We might add the following language as a D.O special condition.: 1. "provide Development Services with approval from SWFWMD verifying permit modification" 2. "as discussed continue landscape improvements on Copland Drive ". RJ From: R] Keetch Sent: Friday, June 19, 2009 4:25 PM To: Todd Vandeberg Subject: Approval conditions for Wheelblast Todd, Here are the approval conditions for Wheelblast. I need to find the file to verify #2, but I think we're in good shape otherwise. The Site Plan Review Committee recommended approval with the following conditions: i. Verify proposed size (length, width and height) of structure and submit final site plans to Development Services. Provide at least two site plans for stamped approval; ii. Provide an up to date SWFWMD permit and /or letter from the engineer verifying that current proposed activities are permitted and/or will not require an additional permit; iii. Comply with the 2007 Building Code (including the 110 mph wind load); iv. Coordinate with fire Department (Keith Williams / Kerry Barnett); v. Coordinate with Utilities Department (David Henderson) regarding utilities / septic. The applicant is advised that City Sewer is available; vi. Landscape buffer w/ water supply needs to be brought up to code on site (western boundary, Tucker Road & Copeland Drive. Applicant to provide a landscape plan to Development Services; 1 vii. Trina Sweet will coordinate with LPA for height compliance of proposed structure with City Airport zoning ordinance. RJ %etch Assistant CityPlanner/Economic Development, Ciry of Zephyrhills, Development Department (813) 780 -0000 x3535 rjkeetch@ci.zephyrhills11.us 2