Loading...
HomeMy WebLinkAbout09-9186 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780 -0020 9186 BUILDING PERMIT Permit Num 9186 Address: 6145 9TH ST Permit Type: RE -ROOF ZEPHYRHILLS, FL. Class of Work: ROOF REPLACEMENT Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: TYSON Est. Value: Parcel Number: 02- 26 -21- 0160 - 00200 -0110 Improv. Cost: 1,918.88 Date Issued: 6/03/2009 Name: PRICHARD, LISA Total Fees: 60.00 Address: 6145 9TH ST Amount Paid: 60.00 ZEPHYRHILLS, FL. 33542 Date Paid: 6/03/2009 Phone: (813)545 -5593 Work Desc: REROOF METAL ROOF OVER HOMEOWNER REROOF RESIDENTIAL 60.00 ' 1 vE� EafE p ,N i _ �zav •: ''`s2\ "yht *-0 P irt DRY IN ROOF INSP TAPE JOINTS ROOF INSP FINAL `(- ('1 .-Oq REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to any one of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." 4 �s GLvt�t -' 0 CONTRAC OR SIGNA RE PERMIT OFFI rR PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER _ R ft . • - City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: �1 �� �l' �u'' G� J `t / �Gc Con Date Received: 6 19 D ? Site: (x/15 Q S Permit Type: itelet-P — X l' Approved wino comments: Cl Approved w /the below comments: Denied w /the below comments: ❑ R , ► , , (4_1 a r, y / t Cli d'/ ► / : I, / 2) i tUv6L P Arat I �,/r ?/ f(' 9 `- t>e � . t ' IriA,1 S c rt5�-P Gk C d This comment sheet shall be kept with the permit and/or plans. / j . S '-. . _ 6 - 0/ , • KalSwitzer — P1 y ' Examiner Date Con ctor .02 and/or H eowner (Required when comments are present) 813 -780 -0020 City of Zephyrhills Permit Application 6 , 0 Fax -813- 780 -0021 Building Department �} i �7 / Date Received S `L I � � Phone Contact for Permittin. 8 (J ( -- /( 7/ Owner's Name I-1 5 A P21e/ ? 4/2 (D Owner Phone Number 5(3 ' SAS' 5S 3 Owner's Address Cpl( S 9 Z /7( 4(/ / ft 3. . Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address 7 "JOB ADDRESS CO ( q L C ' [ 'i /i t U5 / . 335 q LOT # SUBDIVISION PARCEL ID# 0.4 o2 a 1 ©l ' .(0U 006109 011 0 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD /ALT n SIGN 1 I MOVE 1 I DEMOLISH )4 INSTALL REPAIR PROPOSED USE 1 '›C 1 SFR [ COMM n OTHER 1 1 TYPE OF CONSTRUCTION n BLOCK ( I FRAME I I STEEL ni OTHER I DESCRIPTION OF WORK /Q6 /80,1)r 157K 54 � , F 4/IC BUILDING SIZE SQ FOOTAGE HEIGHT 1 BUILDING $ iq / a, VALUATION OF TOTAL CONSTRUCTION 1 ELECTRICAL $ AMP SERVICE 1 I PROGRESS ENERGY 1 1 W.R.E.C, 1 PLUMBING $ 1 MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION GAS n ROOFING 1 I SPECIALTY n OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA n YES I �r BUILDER I COMPANY / / � � *MA OLv /0 SIGNATURE / ' ` (sl REGISTERED I Y / N FEE CURRENT Y / N Address License # ELECTRICIAN COMPANY SIGNATURE REGISTERED I Y/ N 1 FEE CURRENT 1 Y/ N 1 Address 1 1 License # PLUMBER COMPANY SIGNATURE REGISTERED 1 Y / N I FEE CURRENT 1 Y / N 1 Address License # I MECHANICAL COMPANY SIGNATURE REGISTERED 1 Y/ N I FEE CURRENT I Y N I Address License # OTHER COMPANY SIGNATURE REGISTERED 1 Y/ N I FEE CURRENT I Y/ N I Address I 1 License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R -O -W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (3) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R -O -W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. * ** *PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $5000) ** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades A/C Fences (Plot/Survey /Footage) Driveways -Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division — Licensing Section at 727 -847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT /UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89 -07 and 90 -07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water /Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law — Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner ", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S /OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection - Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District - Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers - Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services /Environmental Health Unit - Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency- Asbestos abatement. - Federal Aviation Authority- Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V" unless expressly permitted. If the fill material is to be used in Flood Zone "A ", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TH YOUR LENDER AN ATTORNEY ' YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WI BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT (F.S. 117.03) �1 OWNER OR AGEN y, / g I j CONTRACTOR D a-vK ' c /f' csi H� - F � ''"" X711 Subsc b d ands m to r affirmed) be ore me this Subscribed and swo (or affirmed me this 7 7-01 by C4.4GtC-rx)C /� /xi N A44 -4 s= 29-09 by A.44 II�(fKlit:1416 Who is /are personally known to me or hash ve produced Who is /are personally known to me or ha /haven e produced . o as identification. Notary Public ;r Ps'� JACQUELINC BOGES Notary Public Y Commission DD 621833 ComEprs •4+ JACQUELINE BOGES s s = . `� Commission No. �` '" "'' Expires December 12, 2010 .rnmmigalgfi DO 621833 aole , o�'•�. ', Expires D ecember 12, 2010 oF„ F Bnndgd Thn4 T'Qy Non InfluMncn NW. 345 • •j /j knndsd Thom Tr.,Y FniH ingbMnwp00.:dM.mt Name of Notary typed, printed or stamped Name of Notary typed, printed or stamped May 29, 2009 To Whom It May Concern: I, Lisa Prichard authorize my father, Eugene R. Mimnaugh, Power of Attorney to sign on my behalf documentation for building permit. kQ ( ... A S Lisa Prichard The foregoing instrument was acknowledged before me this 29 day of May, 2009, by Lisa Prichard. She is personally known to me or has produced as identification. qlmidllhillyhawdb #0" a YOSELYN CRUZ • / 1 *" �`' Notary Pubic - SON d Florida /I 1 ` • CarrniMo Enke, !an 4, Toro ► Yosel n !Cruz, otary Publ' State of I • � �' Commission � � saoo7 Bonded By Winn Notary Ann. ► Florida OTIONNIPINWIllpowlemqprummipqrairwIli My Commission Expires: _ern 4 /, (90/0 � s 9 s, 0.6 !mss : is DISCLOSURE STATEMENT FOR OWNER CITY OF ZEPHYRHILLS BUILDING DEPARTMENT 1, 4(54 0 Pi /Gh4W have read - and fully understand and agree to the provisions of this instrument. The undersigned states and affirms that he or she is desirous of constructing, renovating, adding to or reroofing his or her own domicile, that he or she actually occupies, or will occupy by said domicile, and same is not for rent, lease or sale. That he or she shall comply with the following conditions: 1. That the owner and he or she alone shall act as the builder for all phases of construction. 2. That the owner will comply with all provisions of the City of Zephyrhills ordinances and codes pertinent to the building. 3. That in the event various phases of construction are subcontracted, he will engage only properly licensed subcontractors and will personally supervise such work. 4. That in the event the Building Inspector shall require corrections to be made, the owner will assume full responsibility to insure they are made, and upon completion will call for a reinspection before proceeding with the building. 5. That the owner shall assume full responsibility for the construction and will not expect supervision of his work from the City of Zephyrhills Building Department. 6. That prior to final inspection any additional fees, including reinspection fees, must be paid in full. A written request from this office shall constitute an official notice to pay additional fees. 7. That the owner shall comply with all City, State and Federal laws in regard to social security, workman's compensation, lien laws, etc., where applicable. B. That the owner shall comply with all the safety codes issued by the Florida Industrial Commission. 9. State law requires construction to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor with certain restrictions even though you do not have a license. You must provide direct onsite supervision of the construction yourself. You may build or improve a one - family or two - family residence or a farm outbuilding. You may also build or improve a commercial building, provided your costs do not exceed $25,000. The building or residence must be for your own use or occupancy. It may not be built or substantially improved for sale or lease. If you sell or lease a building you have built or substantially improved yourself within 1 year after the construction is complete, the law will presume that you .built or substantially improved if for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building. It is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any person working on your building who is not licensed must work under your direct supervision and must be employed by you, which means that you must deduct F.I.C.A. and withholding tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. r G OWNER'S SIGNATURE WIN - t ., , t I DATE ADDRESS of -���I�1i i hL'iil'� , PHONE 5/ 3 5W5 SS%3 WITNESS PERMIT # y n • r ' ° �� v {$ r • 4 rats t om. a rt' -v, ::-5,--7:-.1-7',7---'. t � 01 # t,yt- '<_s 'V -, i :'. S f c 1 ..,.& 4 w � . f '',' ur n a j '' tx • ~g .li, ' ' i v ��_ METAL SYSTEMS INC. ` 4 GALVALUME WARRANTY m k . -V METAL SYSTEMS INC. warrants to the buyer that METAL SYSTEMS INC.'S hot dipped aluminum -zinc alloy coated t' f k *' . , 7' GALVALUME (T) sheet steel sold for use as unpainted steel building roofing and siding panels, if erected within the k. + f i.;., United States, will not rupture, fail structurally, or perforate within a period of 20 years after shipment from METAL ,. r SYS TEMS INC. due to exposure p ' posure to normal atmos heric corrosion ter ....,,e,.§1 -.0 # � , This warranty My DOES NOT APPLY to sheets ex posed at any time to corrosive or aggressive atmospheric conditions including but not limited to: E F 1. Areas subject to salt -water marine atmospheres or to constant spraying of either salt or fresh water. ;� 2. Areas subject to fallout or exposure to corrosive chemicals, fumes, ash, cement dust or animal waste. 1 k �• 3. Areas subject to water run -off from lead or copper flashing or areas in metallic contact with lead or copper.cs< Wit. ' y ` 4 Conditions/circumstances where corrosive fumes or condensates are generated or released inside the ,, building. *x d am , a"' `,,,,i.. ' This warranty DOES NOT APPLY in the event of: ' ,":,��'' • : 1. Bends less than 2T for sheet thickness 0.030 and thinner and less than 4T for sheet thickness 0.031 and 4 { - . s - thicker. s { ' , 2. Slopes of the roof or sections of the roof flatter than V.:12. tt ‘ , r 3. Mechanical, chemical, or other damage sustained during shipment, storage, forming, fabrication, or during , or after erection. > -� � : 4. Forming which incorporates severe reverse bending or which subjects coating to alternate compression '. , ' and tension. ,4 r ` pr 5. Failure to provide free drainage or water, including internal condensation, from overlaps and all other ` ` ' 43-r : Tr ` surfaces of the sheets or panels. w � 6. Failure to remove debris from overlaps and all other surfaces of the sheets or panels. . �� .. 7. Damage caused to the metallic coating by improper roll forming, scouring or cleaning procedures. : , , ;z.:. 8. Deterioration of the panels caused by contact with green or wet lumber or wet storage stain caused by ` ;; { '"' :{ # water damage or condensation. 4Y y r ► 9. Presence of damp insulation or other corrosive materials in contact with or close proximity to the panel -W 10. This warranty does not apply in the event of deterioration to the panels caused directly or indirectly by ' t r ' panel contact with fasteners. Selection of suitable long- lasting fasteners to be used with Galvalume ' k roofing and siding panels rests solely with the Buyer. +rte , 5 = � r . ti 4 Y1 ; y • y 1, This warranty shall be subject to the stipulations, limitations, and conditions hereinafter set forth: "° =� W ;f iF k cik+aa; �,, ,,-,...1,-,,, X , 1. Metal Systems, Inc 's liability for breach of this warranty shall be limited exclusively to the cost of either repairing ; °= : -7::-, : s11 A � i I , r onconformieg panels, or at Metal System's Ire's sole options of frnishirg FOB Bayer's plaid sufficient sheet = r eroded to enable Buyer to fabricate replacement panels for the rorcorforming panels. � - . . 2. Metal Systems, Inc shall rot it any event be liable for the cost of tabor ezperded by others on any noeweformirg 1' sheet or for ar V l '' special, V. any spec' , indirect or consequential damages 17 i'' have beer Nonconforming. to ar ywe by reasos of the fact that such panels shall b e rb , A , '' 3. Claims must be promptly reported in writing to Metal Systems, Inc. and Metal Systems, Inc. shall be giver a . reasonable opportumity to inspect the pate's claimed to be nonconforming. Adequate idertificatios of the material � Y Z v i . ti , mvohred In the daim, irdrding date of iastallatior, Metal Systems, Inc. order number, invoice number, and date of V? ?-; shipment must be established by Buyer. _ ;s* 4. Buyer shall exercise diligence in inspection of sheets as received from Metal Systems, Inc. so as to mitigate repair 7 ' t„r fix _ or rep +� " 5. Metal S ystems, Inc. extends this warranty solely to the Buyer. This warranty is eon- transferable and non- 1 ' assigeable Vs 1 :. '''' e 6. Metal Systems, Inc . reserves the right to terminate this warranty at any time (expect as to orders already accepted) Epee the giving of written notice thereof. a x; , 'tea s , :. ; i , METAL SYSTEMS, INC. MARES NO GUARANTEES EITHER EXPRESS OR IMPLIED BEYOND THE FACT HEREOF INCLUDING, WITHOUT : • : a. `{ „ ' LIMITATION WARRANTIES OF FIT AND MERCHANTABILITY MW SHALL HAVE NO OTHER LABILITY WITH RESPECT THERETO. �=- `, i A pr r i ti , a < to ' y sx,. ®. ti+ ,.r s... 4'4" ` » �,��, } , � w s L � " car h " `its" ' ' ' 11 : , y, - ,, • -. , Z " F' - L ' � �' -^.'"-_,,,,...;-''1'7 c. . •off 3, ice, [} ,it " 46",4,,'6.'?` . - - . • A -. i„ ..� �,:tM .. sF1 C o mmun ity Affairs rocA HOME A9OU1" FICA ginZEZZMy CONTACT DCA. BCIS Home ! Log In Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map ' Links Search 01 Product Approval i l USER: Public User Corn rnunity � Y ✓ Affairs Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL6508 it COMMUNITY PLANNING Application Type e HOUSING b COMMUNITY ° 2004 Code Version DEVELOPMENT EMERGENCY Application Status A r ed MANAGEMENT Comments *OFFICE OF THE Archived SECRETARY Product Manufacturer Metal Systems, Inc. Address /Phone /Email 3301 Paul Buchman Hwy Plant (813) City, FL 752- 708 gALL WORK SHALL COMPLY WITH AU flvalldation@ya LING CODES, FLORIDA WitilW CODE, NATIONAL ELECTRIC I# �+�. AND Authorized Signature Steve Waller CITY OF ZEPH i if 5 IORD flvalidation @yahoo.com Technical Representative Address /Phone /Email Quality Assurance Representative REVIEW DATE- L ?f Address /Phone /Email c ` R" ' P r� Lk` i ti <.� : 1 i1E�+}�a 6 5 Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who Terrence E. Wolfe developed the Evaluation Report Florida License PE -44923 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date Validated By Locke Bowden Validation Checklist - Hardcopy Received Certificate of Independence FL6508 COI _ FET Letter of Cert.PDF Referenced Standard and Year (of Standard) Standard y r FLORIDA BUILDING CODE 004 UL 1897 998 http: / /www.floridabuilding .org/pr /pr_app_dtl. aspx ?param=wGEVXQwtDqubsyUdumBSk... 6/23/2008 1 ub'., I V1 J • UL 580 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/09/2006 Date Validated 06/21/2006 Date Pending FBC Approval 06/23/2006 Date Approved 07/12/2006 Summary of Products FL # Model, Number or Name Description 6508.1 .26 Ga. PBR R PANEL 26 GA PBR R PANEL Limits of Use Installation Instructions Approved for use in HVHZ: No FL6508_RO_II_PBR Details .PDF Approved for use outside HVHZ: Yes Verified By: TERRANCE WOLFE PE 44923 Impact Resistant: N/A Created by Independent Third Party: Design Pressure: +N /A/- -136.2 Evaluation Reports Other: - 136 .2PSF @10 "O.C. -113.5PSF @12 "0.C. FL6508_RO AE 26GA PBR Eval Report.PDF - 56.75PSF @24 "0.C. NOT FOR USE IN HVHZ. FL6508 RO AE 26GA PBR Load TBL.PDF INSTALL PER MANUFACTURERS DETAILS. Created by Independent Third Party: 6508.2 126 Ga. RIB PANEL 126 GA RIB PANEL 36" WIDTH Limits of Use (Installation Instructions Approved for use in HVHZ: No FL6508 ROII Rib Details .PDF Approved for use outside HVHZ: Yes Verified By: TERRANCE WOLFE PE 44923 Impact Resistant: N/A Created by Independent Third Party: Design Pressure: +N /A /-- 173.5PS Evaluation Reports Other: - 86.75PSF 024 "O.C. - 173.5PSF @12 "O.C. FL6508RO AE26GA RIB Eval Report.PDF NOT FOR USE IN HVHZ. INSTALL PER FL6508_RO_AE 26GA RIB Load TBL.PDF ` MANUFACTURERS DETAILS. Created by Independent Third Party: )6508.3 129 Ga. RIB PANEL 129GA RIB PANEL 36" WIDTH Limits of Use Installation Instructions Approved for use in HVHZ: No FL6508 Details .PDF Approved for use outside HVHZ: Yes Verified By: Terrence E. Wolfe PE 44923 Impact Resistant: N/A Created by Independent Third Party: Design Pressure: +N /A /- 168.5PSF Evaluation Reports Other: - 168.5PSF @12" O.C. - 84.25PSF @24 "O.C. FL6508_RO_AE_29GA Load TBL.PDF NOT FOR USE IN HVHZ. INSTALL PER FL6508 AE 29GARIB Eval Report.PDF MANUFACTURERS DETAILS. i Created by Independent Third Party: Back Next DCA AdministratioR Department of Commun ty Affairs Florida Building Code Online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399 -2100 (850) 487 -1824, Fax (850) 414 -8436 ® 2000 -2005 The State of Florida. All rights reserved. Copyright and Disclaimer Product Approval Accepts: 1E9 II http: / /www.floridabuilding.org /pr /pr_ app_ dtl .aspx ?param=wGEVXQwtDqubsyUdumB Sk... 6/23/2008 Installation Instructions METAL SYSTEMS, INC. 9 -5 Rib Panel metal roofing panels are a strong, resilient, economical, eye- catching solution to the increasing interest and requests for metal roofing opportunities. Panel applications can cover residential homes, commercial applications, agricultural and utility buildings in Florida. 9 -5 Rib Panel metal panels provide a 36 -inch coverage with 3 /4 -inch ribs on nine -inch centers, and utilize an anti- siphoning channel to provide protection from severe weather conditions. Both panels and trim are fabricated using state -of -the -art computerized equipment at our manufacturing facility Plant City, Florida to assure uniformity and consistency in manufacturing the product. Two gauges of material are available - - -26 gauge and 29 -gauge metal panels. Your METAL SYSTEMS, INC. Representative is waiting to assist you in making the best choice for your particular roofing needs. Panels are roll - formed to the lengths specified by customers in either galvanized, Galvalume or multiple colors of painted 26 gauge and 29 gauge high- tensile metal, ready for either customer pickup or on -site delivery. METAL SYSTEMS, INC. also stocks a complete line of fasteners, sealant, and other accessories to every need of either the do- it- yourself homeowner or roofing contractor. Both in -stock and custom -made flashing and trims are available in all colors as well. The paint system applicable to our product provides exterior protection plus superior resistance to corrosion and ultra violet radiation. All of METAL SYSTEMS, INC. 9 -5 Rib Panel finishes are of the highest quality in the industry. ROOF PITCH METAL SYSTEMS, INC. panels require a specified degree of pitch to ensure proper water drainage. The minimum roof slope recommended for all panels is 3 inches of rise per foot. If the slope of the roof is below a 3/12 pitch, contact our representative before using metal roofing on less than a 3/12 pitch. FLORIDA BUILDING CODE REQUIRES A MINIMUM OF A 3/12 PITCH. ROOF APPLICATION Panel installation should begin at the gable end of the roof opposite the prevailing rain - bearing wind (this will provide added assurance against wind - driven rain being forced under the laps). Measure one panel width in from the roof edge. At this point, snap a chalk line from ridge to eave. Place a leading edge of the first panel along this line. It is extremely important that this panel be laid square to the eave and ridge so that the remaining panels will line up square on the roof frame. It is wise to have a person at the eave and at the ridge to ensure that the proper panel coverage is being maintained across the roof. Make sure that the metal panels are correctly side - lapped. In applications where end - lapping is required, the upper panel on the slope should lap over the panel that is lower on the slope. Lower roof pitch requires a greater amount of panel overlap. All end -lap applications require two horizontal rows (across the panel) of butyl sealant tape and proper fastening to ensure a maximum water seal application. Providing an overhang of 2 to 3 inches is recommended to provide a drip edge, although only a 1 -inch overhang is required where gutters are used. The open metal panel ribs at the eave can be sealed with inside closures. For maximum weather - tightness, a row of butyl tape can be applied above and beneath inside closures. Screwing panels will leave raw metal particles that can cause rust marks on panels and trim. Likewise, any particles left on the roof caused by the application of screws must be removed. Care should be taken to remove all loose particles from roof surfaces after application. To cut panels lengthwise: Note carefully where the panel is to be cut, and, using a straightedge, score deeply down the length of the panel with a sharp- pointed utility knife. Folding the panel along the score mark, and bending back again if necessary, should produce a clean break in the panel. Using sheet metal hand tools would be preferred, if you chosse not to purchase these specialized tools be sure that utility knife stays sharp. ORDERING ROOF PANELS AND SCREWS Care should be taken when ordering metal panels that correct length measurements are stated to avoid having to take corrective measures after purchase. Panel lengths should fall 2 to 3 inches short of the ridge when a vented ridge is desired and should extend 2 to 3 inches past eave to allow a sufficient drip edge (except concerning gutters). The METAL SYSTEMS, INC. sales personnel are ready to assist customers with information specific to their particular metal roofing needs. Specially - washered screws applied through the flat of the metal is the recommended method used to attach metal roofing panels. 1 -inch screws can be used if penetration of only 3 /a inch is either necessary or desired; otherwise #10x1 -1/2 inch screws are recommended for metal to wood application. 2 -1/2 inch screws are also available, and are often applied by installers who hold to through- the -rib fastening, and for ridge cap application. ORDERING AND APPLYING TRIM Common flashing for metal roofing is the ridge cap, which is applied at the peak of a roof where two opposing roof slopes join. Other flashing include transition flashing, end wall, side wall flashing, and valleys. Eave flashing include gable flashing and eave drip, which are commonly applied above fascia trim. For a roof pitch exceeding 5/12 (a 5 inch rise in 12 inches), the slope of the roof should be specified upon ordering ridge caps, end walls, and eave drip, Verify local code requirements. Both slopes should be specified when ordering transition flashing if a steeper roof slope meets a lesser slope. At the gable edge, the use of gable trim adds to the appearance of the structure and protects the fly- rafter, and a side wall flashing is used where the side of a panel butts up against an adjacent wall. In both instances, the installer /contractor should be careful to seal between the gable rake or side wall and panel with butyl Specified separately from that used on the drip edge when ordering. To prevent penetration of water, insects, and debris at the ridge, outside closures may be inserted between the ridge cap and the top end of the pane;. Screws are applied through the ridge cap, closure, and rib in at least every other rib of the panels. At least a #10 x 1 1 /2 " and up to a 2 1 /2 " screw should be used for attaching ridge caps. Self - drilling lap screws can be used to attach ridge caps. See Diagram: Drawings attached to this guide. NOTE: Diagram drawings are typical in this installation guide per product specifications or an equivalent product. TYPICAL EAVE DETAIL Lave Drip & Fascia k -- 3 " —r FHA Style ED-3 Style ? Eave drip Eave drip {.,;y, a -rya^ .& r a k 'a 4 For custom eave drip, specify the amount of the eave that will be covered (dimension "a "), and , for steeper roofs, specify pitch. If fascia is desired, specify the dimension you order will concealed by the eave drip. Eave drip and fascia provide a complete appearance along the drip eave of the house, as well as providing protection for the materials they cover. The eave drip should completely cover the top edge of the fascia. Inside closures, provide for sealing off the open ribs of the panels, as an alternative option. TYPICAL VALLEY DETAIL :-.\--...:::..-2...-..:.:,:..::.:;::-:,- ,.--_-_-_z_ii_..::::::::::,...„.._____ L N:. i ---,,,.. . jjj ff 7 f ..............r...................z\drpn..........e...................._ ,,,E.,,_,rF . ' , , _ panc.1 Performed Valley Pre - formed valleys use a diverted to prevent water from rushing under panels on the opposite side therefore channeling water off the roof. Expanding foam closures (A -10 Tape) are generally used to assure a good seal. ik\I 4 e ' • C I i t ' 7' 1 \ \ ;' _ Huai tam — ti t --1 t' , _ Elan -I stsIe 711 ,., GABL E FLASHING OR EQUIVALENT Gable flashing is used to trim the edge of the roofing panel at the gable end of the roof. It should match the eave drip extends along the drip edge of the roof. If the panel is allowed to hang over the gable end, eave drip can be used as an alternative. Butyl tape between the trim and panel eliminates potential leaks. SIDE -WALL FLASHING OR EQUIVALENT caulk iSolar Seal recurnmended _ . caulk edge (order S11/4C) (used it sidewall not — \\\ b covered by siding'r Mg& Butyl tale 3 '4" a � . J I� tt ► 1 Sa of x*Lndurd . i fr wll trim Side wall flashing is applied when the side of the roof butts up against an adjacent wall. The wall -side of the flashing can either be covered over with siding or sealed with counter flashing. Butyl tape should be applied where the "foot" of the flashing attaches to the roof, and, if used, along the top edge of the counter- flashing. 1 N iiiii ' : . 101111111111111111. f F - • tit • e au : k (.50.t3f 593P -..3J }k edge totder $W ( Lsed f end'a3•1 •ot wove red D s d rg i . --- 3, _ Like the ridge cap, the END WALL FLASHING diagrammed above can be sealed using outside closures. End -wall flashing or equivalent is applied where the upward slope of a roof meets a wall. The wall side of the flashing can be covered with siding or counter - flashing, and outside closures are used to seal between the flashing and the panel. Roof slope should be specified when a roof slope exceeds 5/12 pitch. Transition Flashing or equivalent - -- prevents leakage at the point where two different roof pitches meet. .... --'...-- „.,...„---- . .7..„..." FY f .�F r- f i i 2110 46,, -'. ,,,....,,....,... „. " . ...e . " .e''''''''''''''''''''" cI tr ur: __ i - . a _ The transition flashing provides a continuous drainage where two slopes meet. It is sealed on the lower side with outside closures. For custom transition flashing specify the pitches of the two roof slopes and, if required, specify dimensions "a" and "b" ii►. ti ti - _ ', .� 'ti -, a T :. '- - - war: } .1111111111111111*- rr< V The RIDGE CAP is used to seal the point at which two upward slopes meet. This can be both along the ridge of the roof as well as a covering for a hip. Either wood -grip or self - drilling lap TEK screws are applied through the ribs of the metal roofing panels. tl li� Cli" yur f xi1'anding t)uttiid Foam Debris, insects, prevailing rain can find easy access under the ridge cap, so closures are often used to either totally or partially seal the opening. Closures under ridge caps are available in 3 types: solid, vented, and hip valley type. ti Pipe Boots provide a water tight seal around roof vents and come in a variety of sizes. Boots seal with caulk or butyl tape and conform to the shape of the metal panel ribs. KEEP METAL ROOFING PRODUCT MATERIALS DRY Paint and finishes of METAL SYSTEMS, INC. panels and trim are designed to endure severe rain and wet weather conditions. CAUTION: Neither paint, galvanized, nor Galvalume finishes, are designed to be in continuous contact with water or condensation for long periods of time. Damage will result if uninstalled panels or trim are allowed to remain wet in storage. Be sure to store material that will not be installed immediately in a dry location. Wet material should be air -dried and re- stacked if installation immediate. NOTE: Plastic should not be used to cover metal panels. HOW TO FIGURE SCREWS: On low-pitched roofs, butyl tape or caulk should be applied at the panel lap to keep water from overflowing the lap. For 2 -foot spacing between rows of screws, multiply the total linear feet of metal times 2.7. Example; Ifyour order is 1500 feet of 9 -5 Rib roofing. 1500 x 2.7= 4050 screws would be applicable for fastening. Contact your METAL SYSTEMS, INC. representative for a free estimate. Metal roofing application can be aided by pre- drilling panels, allowing screws to go quickly and accurately into the desired spacing. Pre - drilling will work provided that pilot holes are placed accurately in the proper locations on panels. Purlin spacing must be uniform and carefully measured. HIGH VELOCITY WIND ZONES For solid decking, at least 1 %2 - inch structural plywood or OSB (5/8" for any High velocity wind zone of 120 and above) supported on rafters at a max of 24" o center. Battens: 9-5 Rib Metal Roofing can be separated from the moisture barrier by minimum, nominal 1 "x3" yellow pine battens s on maxim 7'4" c o r accordi t : SCE; 7 -98 raicuia ions were applicable. CAUTION: Direct contact between pressure treated lumber, green, damp, and metal roofing must be avoided in order to prevent potential corrosion and moisture buildup. THE battens must be fastened to the roof deck with minimum #6 screws at 12" on- center or two mimnimum 8d common or pneumatic nails spaced 8" on- center or one every 4" on- center (or by applicable calculations according to ASCE 7 -98.) Battens must be installed to support the entire width and length of ridge, eave, hip, valley, and gable end trims. Battens are optional if re- roofing over shingles. Note: Re- roofing over shingles without a batten is allowed providing the roof has been checked by a licensed roofing contractor to insure levelness and pullout integrity. Put down 30# Felt with a 30" lap on Felt Paper. Pulin can be up to 30 inches for 29 -gauge (2 feet is most common ) and up to 4 '/2 feet for 26 -gauge roofing. Screws should be placed on both sides of the ribs on the eave Screw Spacing (purlin) Liner feet of panels in your 12 inch 18 inch 24 inch 30 inch order 50 270 180 135 108 100 540 360 270 216 200 1,080 720 540 432 300 1,620 1,080 810 648 400 2,160 1,440 1,080 864 500 2,700 1,800 1,350 1,080 600 3,240 2,160 1,620 1,296 700 3,780 2,520 1,890 1,512 800 4,320 2,880 2,160 1,728 900 4,860 3,240 2,430 1,944 1,000 5,400 3,600 2,700 2,160 1,100 5,940 3,960 2,970 2,376 1,200 6,480 4,320 3,240 2,592 Policies Indemnity: All prices and designs are subject to change without notice. Disclaimer: Despite the fact that we have made every attempt at accuracy in this manual, we are not responsible for typographic, printing, or technical errors.