Loading...
HomeMy WebLinkAbout09-9309 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780 -0020 9309 BUILDING PERMIT Permit Number: 9309 Address: 5236 18TH ST Permit Type: RE -ROOF ZEPHYRHILLS, FL. Class of Work: ROOF NEW Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 11- 26 -21- 0010 - 17700 -0120 lmprov. Cost: 6,350.00 Date Issued: 7/15/2009 Name: CONNELL, ROBERT & JERRI ANN Total Fees: 97.50 Address: 5236 18TH ST Amount Paid: 97.50 ZEPHYRHILLS, FL. 33542 Date Paid: 7/15/2009 Phone: (813)788 -4803 Work Desc: INSTALL METAL ROOF OVER EXISTING ROOF _ WA NEUMANN CONSTRUCTION INC REROO RESIDENTIAL 97.50 6 - � ...z �• �".� •' \� \ k = . E 77.1,457 e� &9 > C e \ F, •:°`\ a,gtw'� DRY IN ROOF INSP TAPE JOINTS R90 IN FINAL �� lt(4 REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to any one of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recordi g your n . - of commencement." CO» RA OR SIGNATURE PERMIT OFFI prR ERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780 -0020 9309 BUILDING PERMIT cfr Permit Number: 9309 Address: 5236 18TH ST Permit Type: RE -ROOF ZEPHYRHILLS, FL. Class of Work: ROOF NEW Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 11- 26 -21- 0010- 17700 -0120 Improv. Cost: 6,350.00 Date Issued: Name: CONNELL, ROBERT & JERRI ANN Total Fees: 97.50 Address: 5236 18TH ST Amount Paid: ZEPHYRHILLS, FL. 33542 Date Paid: Phone: (813)788 -4803 Work Desc: INSTALL METAL ROOF OVER EXISTING ROOF vvA UMANN CONSTRUCTION INC REROOF RESIDENTIAL 97.50 P - �:.r i � ?!' F a�� s a s g a a M 3 �- y ��,r g E a �g��� ,� DRY IN ROOF INSP TAPE JOINTS ROOF INSP FINAL REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to any one of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." CONTRACTOR SIGNATURE PERMIT OFFI FR PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780 -0020 City of Zephyrhills Permit Application Fax - 813-780 -0021 Building Department c7 309 Date Received • y - 2-9 Phone Contact for Permitting 3 � (37 Owner's Name l ° E - f C orJAJ Et L Owner Phone Number Owner's Address C �3 6 / <5/, Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS � i g -h S / LOT # SUBDIVISION PARCEL ID# / - Z4 - 2) - 00( : 1 7D ° — 0 /Z " (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR C ADD /ALT 1 I SIGN 1 I MOVE ( I DEMOLISH INSTALL REPAIR PROPOSED USE I I SFR 1 I COMM 1 1 OTHER TYPE OF CONSTRUCTION 1><, I BLOCK I I FRAME ( I STEEL n OTHER DESCRIPTION OF WORK IAJ31 4/- L Mi (t'Y L ROOF UVC EXIST, 5d (Ai L� BUILDING SIZE SQ FOOTAGE HEIGHT (- $ /'rV BUILDING $ / 35.D 0 VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ AMP SERVICE I 1 PROGRESS ENERGY I 1 W.R.E.C. I PLUMBING $ pV I MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION GAS � ROOFING I I SPECIALTY 1 1 OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA 1 IYES nNo 're V / 11/1/1•°/1A/A/ l �l/t/5!t v�T - -" BUILDER COMPANY ' SIGNATURE / REGISTERED I Y/ N I FEE CURRENT I Y/ N I Address 2 3 0( / / f j f ;--/ U- 1,44/ -4 7/✓ "o // 1 License # l ' 3 - 6 /‘ 6 ELECTRICIAN COMPANY SIGNATURE REGISTERED I Y/ N i FEE CURRENT I Y/ N i Address License # PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT 1 Y/ N I Address License # T MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y/ N I Address License # OTHER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y/ N I Address 1 License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R -O -W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions /large projects COMMERCIAL Attach (3) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R -O -W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. * ** *PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $5000) ** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades A/C Fences (PIot/Survey /Footage) Driveways -Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division — Licensing Section at 727 -847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT /UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89 -07 and 90 -07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water /Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law— Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner ", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S /OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection - Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District - Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers - Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services /Environmental Health Unit - Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency- Asbestos abatement. - Federal Aviation Authority- Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V" unless expressly permitted. If the fill material is to be used in Flood Zone "A ", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING LENDER OR AN ATTORNE FINANCING, CONSULT YOUR PROPERTY. IF YOU INTEND TO OBTAIN WITH YOUR Y BEFORE RECORDING OUR NOTICE OF COMMENCEMENT. FLORIDA JURAT (F.S. 117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to (or affirmed) before me this Subscribed and sworn to (or affirmed) before me this by Who is /are personally known to me or has/have produced Who is /are personally known to me or has /have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. typed, printed or stamped Name of Notary typed, printed or stamped Name of Notary typ P • City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: (A) A Al i''« el Date Received: ( - Z- `Y 09 Site: S23(2 / 8 t sr Permit Type: M -aif /''2A Approved wino comments Approved w /the below comments: ❑ Denied w /the below comments: ❑ This comment s heet hall ke t with the permit and /or plans. Kalvin S itzer - Plans aminer Date Contractor and/or Homeowner (Required when comments are present) I Pagel � Florida Building Code Online Y«.l..AFgtCI , ElrirxTalAF.11 ❑F• ► ' !"'" 'r; f '.. .�, . ,, ISIMMENEXUSSOMMI rnmurt ty 0 = BcIS Home 1 Log In I User Registration I Hot Topics 1 Submit Surcharge I Slats & Facts { Publications 1 FBC Staff I BCIS Site Map 1 links ' Search 1 0 61. lik. " r."' Product Approval USER: Public User PZI C. Grllnll11PIT 1 ... Aft „ ,= Prixkct.AAPProol. Meng > PrildkSt.BrA1>ileattial.Sedreh> aLcatLortalnt> Application Detail ONOMMOSONOOMO FL # FL9610 -R1 1:.CC#k'tf'htN4r,FrP, >AMmtto Revision Application Type Revi Revi Irtks/NGa MLln4ty Code Version drv> ig7PmeNf _ Approved Application Status F M v .Vie ,yvr,teNt Comments • ►office. r mu Archived Product Manufacturer UNION CORRUGATING COMPANY Address /Phone /Email 701 S. KING ST. FAYETTEVILLE, NC 28301 , �.�( (910) 483 -0479 Ext 24 ri ,_ e A y DATE �� jthornton @unlonc @ OF ZE P � H . (R �„� I L Authorized Signature Jason Thornton "�a �, EXAMINE jthornton ©un io ncoltrug9UrgI6 m Technical Representative Address /Phone /Email COMPLY WITH ALL FLORIDA Category Quality Assurance Representative Address /Phone /Email ALLWORK SHALL C BUILDIr+ NATIONAL CODE ANt Roofing IDIOM Metal Roofing CODE, ILLS ORD Subcategory. CITY OF ZEP HYR K Compliance. Method Certification Mark or Usting PREVAILING CODES, Certification Agency Miami -Dade BCCO - CER Validated. By Miami -Dade BCCO - VAL Referenced Standard and Year (of Standard) S r _Yam 1995 TAS 100 2003 TAS 125 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 07/08/2008 Date Validated 07/22/2008 Date Pending FBC Approval 07/25/2008 Date Approved 09/15/2008 hm, 1 / www. floridabuilding .org /pr /pr_app_dtl. aspx ?param= wGEVXQwtDgsfeBvzFfKl j %2... 2/25/2009 . Florida Building Code Online Page 2 of 2 7r122:tIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIoescri. ton IIIIIIIIIIIIIIII Min 26 ga., 24" wide, 1/2" high metal roof panel over 9610.1 .1 ood deck use in � e rtification Agency Certificate � - - - - - _ - I 71114Q1,pdf I Limits of Use HVHZ: Yes FL9610 R3 C_CAC_ 0 Quality Assurance Contract Expiration Date Approved for u 05 I I Approved for use outside HVHZ: Yes Instal /2012 Instructions 1 Impact Resistant: N/A De Pressure: +N /A/ - 120. 9 FL9610_3,1_11_471114. CI_ ,Rdf. Other: Verlfled By: Mlaml -Dae BCCO - CER C by Independent Third Party: I ■ Evaluation Reports Created b Inde• -ndentThird Pa Advantage -Lok Min 26 ga., 16" wide, 1 -3/8" high standing seam metal !9610.2 roof •anel over pi ood deck 'Certification Agency Certificate ' -- -- - i C CA �04Q21.4.pdf Limits of Use EL9.61 — & -- _ Approved for use In HVHZ: Yes 07/10/2 nst 07/10/2013 Instructions 0on Assurance Contract Expiration Date Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N /A/ -84.3 I FL9610 R1_II 0B04ca0..•Rdf I , Other: Verif By: M iami -Dade BCCO - CER I Created by Independent Third Party: Evaluation Reports Created b Inde•endentThird Party: Min 26 ga., 16" wide, 1" high standing seam metal roof 9610.3 AdvantageLok II ' • -n et over • I ood deck Certification Agency Certi I Approved o f Use FL961�fZ1 —C CA.0 46k4.4215,R.d_f Data Approved for use In HVHZ: Yes : Quality Assurance Contract Expiration �, Approved for use outside HVHZ: Yes I Impact Resistant: N/A Installation 2/ 7/011 Instructions 1 Design Pressure: +N /A /- 108.15 , FL9610 12/07/2011 RoII 061.00l15pdf II, Other: Verified By: Miami -Dade BCCO - CER I d I Created by Independent Third Party: ,Evaluation Reports I I Created b Inde•endentThird Party: Min 26 ga., 36" wide, 3/4" high metal roof panel over 9610.4 MasterRlb ood deck Approved for use in HVHZ: Yes Cartifleatlon Agency Certificate Limits of Use F12619 R7 CGAC 07071.Q3 Rif Quality Assurance Contract Expiration Date Approved for use outside HVHZ: Yes 09/05/2012 h Impact Resistant: N/A 2012 Instructions Design Pressure: +N /A/ 114.3 , nako_ Installation 11_4 43..Sdf Other: Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports t Created b Inde • endent Third Party: MIE123111 11110311111 nrs admire st at140 Department of CContmnnnY Affairs Florida BotldIap Coda on/ma Codes and Standards 2555 Shurnard Oak Boulevard Tallahassee, Florida 3234 -0036 (850) 487 -182 Fax (850) e 2000 -2005 The State or Florida. All rights reserved• avAnht and Disdalmer Pro duct Approval Accepts: A "6a••Y • b tt,•// >;rww.floridabuilding.org/pr /pr_ app_ dtl. aspx? param= wGEVXQwtDgsfeBvzFfKlj %2... 2/25/2009 I I • MIAMI -DADE COUNTY, FLORIDA MM i� AOE METRO -DADS FLAMER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 BUILDING CODE COMPLIANCE OFFICE (BCCO) MIAMI, FLORIDA 33130-1563 PRODUCT CONTROL DIVISION (305) 375 -2901 FAX (305) 375 -2908 NOTICE OF ACCEPTANCE OA) Union Corrugating Company 701 South Sing Street Fayetteville, NC 23802 -0229 • SCOPE: This NOA is being issued under the applicable rules and regulations � governing Product Control Division and accepted The documentation submitted has been reviewed by Miami-Dade and other areas Div where and acc ep ed by the Board of Rules and Appeals (BORA) to be used in Miami Dade County the Authority Having Jurisdiction (AAJ). d This NOA shall not be valid after the expiration date stated below. The ode County Product pr Pr od uct the Control Division (In Miami Dade County) and/or the AEI (in areas other than Miami Dade or material County) fails reserve her in have this product or material tested for quality assurance purposes. If this pr and the AEI may immeo i n the accepted manner, the manufacturer will incur the expense of such testing revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right ed by Miami Dade County Product Control Division that this pro to revoke this acceptance, if it is deteimin y code. material fails to meet the requirements of the applicable building This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Master Rib® Metal Roof Panel LABELING: Each panel shall bear a permanent label with the manufacturers name or logo, city, state and the following statement: "Miami Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has an there has been no change in the applicable building code negatively affecting the performance TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in of any the materials, use, and/or manufacture o product or this NOA. Fa to comply product, for sales, advertising or any purposes with any section of this NOA shall be cause for termination and removal of NOA. preceded by the words Miami Dade County, Florida, and followed by ADVERTISEMENT: The NOA number p portion of the NOA is displayed, then it shall the expiration date may be displayed in advertising literature. If any P be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA No. 06- 1002.14 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tiger a. • NOA No.: 07- 0713.03 Expiration Date: 09/05/12 Approval Date: 09/06/07 Pagelof6 ..r \ . I'I ROOFING ASSEMBLY APPROVAL: Ca. Roofing Sub - Category: Non - Structural Metal Roofing Material: Steel Deck Type: Wood Maximum Design Pressure -114.3 psf. See Table A herein TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specifications pfioonn Master Rib Metal Length: varies TAS 125 Metal Roof panel coated with various Roof Panel Width: 41" approved coatings of Ceram -A -Star® (Coverage width : 36 ") 1050. Height: 3/4" Min. Thickness 0.019" EVIDENCE SUBMITTED: . Test Aaencv Test Identifier Test Name/Report Date Akzo Nobel Coatings, Lab Test Certification ASTM B -117 Inc ASTM G -23 Ceram A -Star Lab Test Certification ASTM - G-23 PRI Asphalt UCC- 002 -02 -01 TAS 100 05/22/02 Technologies, Inc. Hurricane Test 0293- 0417 -02 TAS 125 06/14/02 Laboratory, Inc. 0293-0611 -05 06/28/05 • NOA No.: 07- 11713.03 •. E xpiration Date: 09/05/12 Approval Date: 09/06/07 Page 2 of 6 SYSTEM DESCRIPTION SYSTEM A -1S: "Master Rib" 26 Ga. Metal Panel Deck Type: Wood, Non - insulated Deck Description: 19 /32" or greater plywood or wood plank. Slope Range: 2 ": 12" or greater Maximum Uplift See General Limitations #2 Pressure: Deck Attachment: In accordance with applicable Building Code, but in no case it shall be less than #8 x 2!' screws spaced at 6" o. c. In reroofing, where the deck is less than 19/32" thick (Minimum 15/32 "), the above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be an ASTM D 226 Type 11 installed with a minimum 4" side -laps and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and I1/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with Union Corrugating Company's current published installation instructions. Fire Barrier Board: Any approved fire barrier having an NOA. Or for class A or B fire rating, install minimum 1/4" thick Georgia Pacific "Dens Deck" (with current NOA) or minimum 4mm thick of Tritex, RockRoof (with current NOA) or 5 /8" water resistant type X gypsum sheathing with treated core and facer or Elk Versashield (with current NOA). Metal Panels and Install the "Master Rib Roofing Panel" and accessories in compliance with Accessories: Union Corrugating Company' s current published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards RAS 133. Master Rib Roofing Panels shall be fastened with a minimum of #9 Hex Head Wood corrosion resistant fasteners with sealing washer. Fasteners shall of sufficient length to penetrate through the sheathing a minimum of 3 /16'. Fasteners shall be place in accordance with fastener detail herein as follows: NOA No.: 07- 0713.03 Expiration Date: 09/05/12 Approval Date: 09/06/07 ; rr<, Page3of6 GENERAL LINIITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Neither rational analysis, nor extrapolation shall be permitted for the maximum design pressures listed in the `Perimeter and Comer" roof areas as noted in Table "A" herein. 3. Panels shall be roll formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Roofing Application Standard RAS 133. 4. All panels shall be permanently labeled with the manufacturer's name or logo, city, state and the following statement: "Miami Dade County Product Control Approved ". NOA No.: 07- 0713.03 , Expiration Date: 09/05/12 ^' Approval Date: 09/06/07 ;go/ o Page 5 of 6 1. Panel side ribs shall be fastened along side of the panel inside rib, one fastener at the overlap. Field panel ribs shall be fastened with one fastener per rib the side of the panel. 2. All fasteners at center ribs and overlap rib shall be spaced at a maximum distance as noted in Table A below parallel to the roof slope. See detail herein. 3. Pane overlap shall be fastened at the high point with' /4 -7/8" long Hex Head corrosion resistant fasteners with sealing washer spaced at a maximum distance as noted in Table A below parallel to the roof slope. See detail herein. TABLE A Maximum Design Pressure Field Perimeter and Corner' Maximum Design Pressure -61.8 psf -1143 psf Maximum Fastener Spacing 30" o.c. 24" o.c. 1. Extrapolation shall not be allowed • i NOA No.: 07- 0713.03 Expiration Date: 09/05/12 Approval Date: 09/06/07 fir!. Page4of6 \ DRAWINGS 36" COVERAGE - 9" 3/4 3/16" •• — 1 7/8" FASTENER w/ WASHER PANEL OVERLAP FASTENER w/ WASHER 9" vP ) SUBSTRATE FASTENING PATTERN OF PANEL • 11 101/1:: 4 30" o.c. For - 61.80psf. (see Table A) 24" o.c. For - 114.30psf. (see Table A) Overlap 2" From Panel End MASTER RIB PANEL END OF THIS ACCEPTANCE NOA No.: 07- 0713.03 Expiration Date: 09/05/12 Approval Date: 09/06/07 moor • Page 6 of 6 0 M M z w z CO 0 � OD OD n� D C7� m m Z z -< m o o r \ .. z \ \ ® m z > 9, —I O coD D �e coD c),-• V 0°3 n iJ \ m , m m 0 rn \ m D \ ICJ o I Fri o < \ c '0 ► n \1 z z f O o .A 71 UNION CORRUGATING sY P B R P as el 56V °" ° °"' u COMPANY RA o 701 SO 10X6 ST .e... MC WE on. 5515 9 o«MiY^� 6- 1a -lDDp V $ FAR70.MLLE, V4 9732 MOM Pk 111H o-SM IA6 045 415-1111 1P 00%W David Yocum 1 111111114' EUINAANN RS'OJ1Ig, RESIDENTIAL • MOBILE HOME • COMMERCIAL 12630 Curley Street, Suite 104 • San Antonio, FL 33576 Phone: 352 -588 -0910 • Fax: 352 -588 -0911 LIC# CBCO58155 - LIC# CCC1326166 www.neumannroofs.com June 12, 2009 Re: Re -Roof Proposal (METAL) Robert & Jerri Connell 5236 18 Street Zephyrhills, FL 33542 gr3- 7/y Neumann Roofing, Inc. proposes to furnish all the labor, material, supervision, equipment, fees and other costs to complete the project located at the subject property according to specifications listed below: 1. Record NOC and pull all permitting required. 2. Install a 30# felt underlayment system over existing shingle roof system to serve as a barrier between existing and new proposed metal roof system. 3. Install new metal drip edge to match color of new installed roof system. 4. Install a new complete Union Master Rib 29 -gauge roofing system on main roof. Color: lL4/ 5. Roof system includes: Union Master Rib roof panels cut to length, ridge cap, rake trim, 6" T -style eave drip, and valley metal; all of matching material finish and color. 6. Haul away all roof - related debris. 7. Our liability insurance coverage is based on completed operations. 8. Provide a 5 -year workmanship warranty. 9. Provide a 30 -year manufacturer's warranty against streaking/fading of painted finish. 10. Provide a 40 -year manufacturer's warranty against rust/corrosion of metal roof system. 11. Payment schedule: Full amount at job completion GAF FL. Contractor #: CCC1326166 — GAF -ELK License #: ME12709 Ml'Ellte 12630 Curley Street- Suite 104- San Antonio • Florida • 33576- Ph: (352) 588 -0910 • Fax: (352) 588 -0911 N i ELAN Rpofin, Inc. RESIDENTIAL • MOBILE HOME • COMMERCIAL 12630 Curley Street, Suite 104 • San Antonio, FL 33576 Phone: 352 -588 -0910 • Fax: 352 -588 -0911 LIC# CBCO58155 - LIC# CCC1326166 www.neumannroofs.com It is understood and agreed the Neumann Roofing, Inc. will be held harmless for alleged or actual damages /claims as a result of algae, fungus, or mold. It is understood the roofing contractor and the roofing contractor's insurance will exclude all coverage, including defense, damages, related to bodily injury, property damage and clean up directly or indirectly in whole or in part for any action brought by mold, including fungus and mildew regardless of the cost, event, product or workmanship that my have contributed concurrently or in any sequence to the injury or damage occurs. Neumann Roofin 's Commitment to Quality: • All work will be supervised by project managers to ensure quality work is preformed according to our proposed contract. • All carpentry work will be performed in conjunction with roofing work, in a timely manner. • All work will be completed by skilled and knowledgeable craftsman to ensure production of high quality of work. • The job -site will be kept free of debris throughout the duration of the project. • The perimeter of the project area will be swept with magnets to pick up any loose nails, staples, or other various scrap sheet metal components. • Neumann Roofing, Inc. is fully insured with workman compensation and general liability insurance. FL. Contractor #: CCC1326166 Cd1F F , L J , GAF -ELK License #: ME12709 NI�'Elite 12630 Curley Street• Suite 104• San Antonio • Florida • 33576. Ph: (352) 588 -0910 • Fax: (352) 588 -0911 i ELIMANN Rgo fi ng , r nc. I RESIDENTIAL • MOBILE HOME • COMMERCIAL 12630 Curley Street, Suite 104 • San Antonio, FL 33576 Phone: 352 -588 -0910 • Fax: 352 -588 -0911 LIC# CBCO58155 - LIC# CCC1326166 www.neumannroofs.com Options 1. grade from 29 -Gage Painted MasterRib to a 26 -Gage Painted MasterRib. 50.00 Total: $(6,000:00) ‘3,c0, 00 1 Upgrades: $ t- :00 Final Total: $ 1 s"z .00 • 100% payment due upon job completion. • Our proposed price is valid until June 26, 2009; after which prices are subject to change. Accepted By: Neumann Roofin: _ I. . # , y_ ../ .0./ Ae_. -_," Date: Date: G`- 71-1°1 FL. Contractor #: CCC1326166 GAFLLI\ GAF -ELK License #: ME12709 ,,' o 12630 Curley Street. Suite 104. San Antonio • Florida • 33576. Ph: (352) 588 -0910 • Fax: (352) 588 -0911 i iiiiii iiiii II 1 111 hill II 1 iiiii hill iIII hill ii i ii i 2009088780 Rept:1250540 Ree: 10.00 DS: 0.00 IT 0.00 06/26/09 Dpty Clerk NOTICE OF COMMENCEMENT Permit N0. PAULA S O'NEIL, PRSCO CLERK & COMPTROLLER 06/26/09 8 4 1 o 1 552 OR BK PG Property Identification No. 11- 26 -21- 0010- 17700 -0120 THE UNDERSIGNED hereby give informs you that the improvement will be made to certain real property. and in accordance with Section 713.13 of the Flonda Statutes. the following information is provided in this NOTICE OF COMMENCEMENT. CITY OF ZEPHYRHILLS PB 1 PG 54 LOTS 12 13 & LOT 14 LESS NORTH 14.00 FT ALL 1 _Description of property (legal description: l IN BLOCK 177 OR 1361 PG 1772 a) Street Address: 5238 1RTH STRFFT 7FPHYRHII I S Fl 33547 -21561 2.General delscription of unprovements: INSTAI 13D -YR UNION MASTFR RIR MFTAI ROOF PANFI C)VFR FXISTINCI SHINPA F RC)OF SYSTFM 3.Owner Information a) Name and address: CONNELL, ROBERT DALE & JERRI ANN; 5236 18TH STREET, ZEPHYRHILLS, FL 33542 - 2156 b) Name and address of fee simple titleholder (if other than owner) Fee Simple Titleholder c) Interest in property Fee Simple Titleholder ontractor Information a) Name and address: W.A. Neumann Construction, Inc. — 12630 Curley St., Ste. 104; San Antonio, FL 33576 b) Telephone No.: 352 - 588 -0910 Fax No. (Opt.) 352 - 588 -0911 5.Sttrety Information a) Name and address: N/A b) Amount of Bond: c) Telephone No.: Fax No. (Opt.) 6.Lender a) Name and address: N/A Phone No. 7. Identity of person within the State of Florida designated by owner upon whom notices or other documents may be served: a) Name and address: b) Telephone No.: Fax No. (Opt.) 8.In addition to himself, owner designates the following person to receive a copy of the Lienor`s Notice as provided in Section 713.13(1)(b), Florida Statutes: a) Name and address: b) Telephone No.: Fax No. (Opt.) 9.Expiration date of Notice of Commencement (the expiration date is one year from the date of recording unless a different date is specified): _ WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED LMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPRO`EMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTALti FINANCLNG, CONSULT YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEME COUNTY OL1T1' OF FLORIDA C: :4 _ � OF PASCO DANIEL RAY BONEBRAKE,I�R /��,Q�/ ' Notary Public, State of Florida patine of Owner or Owners Authorized Officer Director Pa:nier \.anger My Commission Expires June 15, 2012 Conenission No. DD798045 Print Name The foregoing instrument was acknowledged before me this /Z day of V . 20q . by as (type o ithority. e.g. officer, trustee. attorney in fact) for (name of party on behalf of who r - n n 'as executed). Personally Known OR Produced Identification Notary Signature - Type of Identification Produced f 0 5u4F.t Name (pent) ,;,",�E /• ",1 rit,- Verification pursuant to Section 92.525. Florida Statutes. Under penaltie of perjury. I declare that I have read the foregoing and that the facts stated to it are true to the best of my knowledge and belief. / _,,,49,ere...,ez, Signature of Natural Person Sirnmg Above FO RW SNOC,'sd2007