Loading...
HomeMy WebLinkAbout10-10427 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780 -0020 10427 BUILDING PERMIT Permit Number: 10427 Address: 38424 5TH AVE Permit Type: COMMERCIAL ZEPHYRHILLS, FL. Class of Work: ADD /ALT COMMERCIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 11 26 -21- 0010 - 16700 -0210 Improv. Cost: 1,000.00 Date Issued: 5/05/2010 Name: S AND M LEO-- Total Fees: 167.50 Address: 6315 FRONTIER DR Amount Paid: 167.50 ZEPHYRHILLS, FL. 33540 Date Paid: 5/05/2010 Phone: (813)782 -0858 Work Desc: ENCLOSE ARCHWAY/ UPGRADE ELECTRIC UN AT A ♦ N BUILDIN E 52.50 L -- I — AL F E 35.00 REESE ELECTRICAL INC FIRE PLAN REVIEW FEES 50.00 FIRE INSPECTION FEES 30.00 c 5V) • • R 2 ■ - • H PLU MI C N ULA 1• (LING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE -METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE -SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to any one of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." 2/ 44 itp 'te 7 CTOR SIGNATURE PERMIT OFFI FR PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813 - 780 -0020 City of Zephyrhills Permit Application / ,�; Z 1 Fax -813- 780 -0021 Building Department 11 Date Received - / b -( 0 Phone Contact for Permitting -- Owner's Name 60,4 41 iv) . L.1 / S /,-. Many*/ Owner Phone Number �� 3' 78 oL -o t$ Owner's Address J 5 c?)'�h y{° Owner Phone Number '3 i 2 j ' '7 r...7.- 0 es g-. Fee Simple Titleholder Name /OM& CO abelle Owner Phone Number Fee Simple Titleholder Address i 05Vrlf co 6/9_ JOB ADDRESS ( 3 . �� {�YC i(!�l qP 3 C� LOT # SUBDIVISION PARCEL ID# /` -- * 1 - bOio 16 - - Q�-IO r � // 4.01/ ( OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED � NEW ONSTR ADD /ALT SIGN I , 1 MOVE I I DEMOLISH INSTALL REPAIR PROPOSED USE I I SFR 14 COMM I I OTHER I I / TYPE OF CONSTRUCTION I ;/I BLOCK 1 1 FRAME I I STEEL � I 1 OTHER 1 I DESCRIPTION OF WORk,j 1 A� W%Vj O Q —_ C-LG BUILDING SIZE �, 7v. SQ FOOTAGE l Ja7 . HEIGHT f 9LLe/ BUILDINV $ ,S VALUATION OF TOTAL CONSTRUCTION 14.I ELECTRICAL $3%--0 m.9- AMP SERVICE 1 1 PROGRESS ENERGY I I W.R.E.C. I 1 PLUMBING $ I 1 MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION I 1 GAS I I ROOFING I I SPECIALTY I 1 OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA 1 IYES 1 INO 11:13111:0. _ _ -_ • - J r BUILDER / ^. - - i _ � , y COMPANY 1. .. "1: - E: : ,, SIGNATU X , /- REGISTERED I Y/ N I FEE CURRENT 1 Y/ N I Address License # { ELECTRICI \11/�s�- �) ` COMPANY R�/ �,Qw4u.�_, SIGNATURE REGISTERED I Y / N I FEE CURRENT I Y/ N I Address (O . ilLA. 071 z . L.,, License# M4 (5w(353 PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y/ N I Address License # MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y/ N I Address I License # OTHER COMPANY SIGNATURE REGISTERED I Y/ N I I FEE CURRENT I Y/ N I Address License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R -O -W Permit I for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions /large projects COMMERCIAL Attach (3) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R -O -W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. * ** *PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $5000) ** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades A/C Fences (Plot/Survey /Footage) Driveways -Not over Counter if on public roadways..needs ROW f NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division — Licensing Section at 727 -847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT /UTIL TIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees ane Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89 -07 and 90 -07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water /Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law — Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner ", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S /OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection- Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District - Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services /Environmental Health Unit - Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency- Asbestos abatement. - Federal Aviation Authority- Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone "V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A ", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed' by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fillI is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated', by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN_ FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR N • - 17FCOM iii., . FLORIDA JURAT (F.S. 117.03) OWNER OR AGENT i ' _ . i t ' 4 ° .i - • Li- CON - 4. CTOR !� J- ` Subscribed and sworn to (or affirmed) before', me th' i Sub. - ' : • - .'7. i� rmed) before me this q- 12-24 0 by F')`.) (5€- i , • - • by Who is /are personally known to me or has/have produced o is /are personal known to me or has /have produced D r w t, G, r, V as identific as identification. I ( CQ �- � kA; k, � � Q . Notary Publi �`�� .'' � � - • Notary Public top, Co mmisr -l• ', • • 621833 ��D �t ■ C om ion No W� -- .4" EX ca., I mbar 12, 2010 Commi Ion No. 1 v .,. - ,go w !tMF1•d N •Y to ' \ Ck , Y M \ . 6 l1t \ Name of Notary typed, printed or sta ped Name of Notary typed, printed or stamped , ?$ , i ANDREA YOUNG ar: !AL t+a MY COMMISSION # DD 949059 'i. - � EXPIRES: January 9, 2014 •.F ;,Tc• bonded Thru Notary Public UndervYriters ..... Pasco County Parcel: 11- 26 -21- 0010 - 16700 -0210 001 Page 1 of 1 Data Current as Of: II Weekly Archive - Saturday, April 24, 2010 I Parcel ID I 11- 26 -21- 0010 -16700 -0210 (Card: 001 of 002) I Classification 11 - Retail Stores, One Story, All Types Mailing Address Final 2009 Value SANDMLLC AgLand $0 6315 FRONTIER DR Land $37,870 ZEPHYRHILLS FL 33540 -7623 Building $153,182 Physical Address - See All 5 addresses (First Extra Features $0 Shown) 38424 5TH AVE Market Value $191,052 ZEPHYRHILLS FL 33542 -4328 Assessed (Non - School Amendment 1) $191,052 Legal Description (First 4 Lines) See Plat for this Subdivision ./"' Taxable Value $191,052 CITY OF ZEPHYRHILLS PB 1 PG 54 EAST 70.00 FT OF LOTS 21 22 23 & 24 BLOCK 167 OR 5735 PG 496 I Land Detail (Card: 001 of 002) ) Line II Use IlDescription I Zoning II Units II Type II Price (I Condition II Value I 1 I 1100 (ISTORE 1FL2 I 00C2 II 7,000.00 II SF II $5.41 II 1.00 II $37,870 Additional Land Information I Acres II 0.16 11 Tax Area II 30ZH II FEMA Code II X IlCommerical Code(I M5AV2AB Building Information - Use 11 - Retail Stores (One Story) (Card: 001 of 002) Year Built 1937 Stories 1.0 Exterior Wall 1 Common Brick Exterior Wall 2 None Roof Structure Flat Roof Cover Built -Up Tar and Gravel Interior Wall 1 Masonary or Minimum Interior Wall 2 Plywood Panel Flooring 1 Asphalt Tile Flooring 2 Carpet Fuel Electric Heat Forced Air - Ducted A/C Central Baths 4.0 I Line II Description II Sq. Feet I I Repl. Cost New I 1 II SDA II 3,636 II $392,688 I 2 II FST II 1,220 II II $65,880 3 UST II 330 II $14,256 I 4 ll CAN ( I 560 II $18,144 I Extra Features (Card: 001 of 002) I Line II Description II Year II Units II Value I No Extra Features Sales History I Previous Owner I ) BSB HOLDINGS LLC Year II Moth II B ook /Page II Type II Amount I 2004 06 II 5902 / 0732 II WD II $ 2003 II 12 II 5676 / 0621 II WD 0 $0 I 2003 12 I I 5676 / 0623 II WD 0 $ http: // appraiser. pascogov.com /search/parcel.aspx ?sec =11 &twn= 26 &rng=21 &sbb= 0010 &bl... 5/4/2010 Pasco County Property Appraiser - Physical Address List for: 11- 26 -21- 0010 - 16700 -0210 Page 1 of 1 Welcome : Records Search : Parcel Details : Physical Addresses Physical Address List for Parcel: 11- 26 -21- 0010 - 16700 -0210 Displaying 5 records View in groups of: 10 25 50 100 500 Street Number Street Name # Unit 38424 5TH AVE 38426 5TH AVE 38428 5TH AVE 38430 5TH AVE 38430 5TH AVE 1 Pasco County Property Appraiser Page Layout Modified: 2/17/2009 1:10:37 PM The Local Time Is: 5/4/2010 2:31:52 PM http: // appraiser. pascogov. com /search/physadd.aspx ?parcel= 2126110010167000210 5/4/2010 Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (813) 780 -0041 Kerry Barnett Fax (813) 780 -0044 E -mail: kbarnett@fire.zephyrhills.fl.us Plan Review #: 10 -036 Project: Interior Renovation Number of Pages: 4 April 21, 2010 I have received and reviewed the plan for the renovation located at 38424 5 Ave and have rejected it due to the comments listed below. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. There has been no fees assessed at this time and fees will be assessed upon an approved review. 1. A floor plan is needed to show overall layout and location of issues being corrected. 2. Opening in wall that is being closed in needs better detail. UL number listed on the attached sheet providing ratings shows 2 X 4 studs not 2 X 6 studs. It also shows 5/8" Type "X" on both sides but that is not shown on the detail. 3. Provide UL details of # 1479 and 2079 mentioned on drawn plan for penetrations. 4. There is no mention of the loft. This needs to be calculated for load capacity per square foot to ensure it meets specifications. As it is constructed now the head height is below the requirement and the stairs do not meet code. It is recommended to just remove the loft. 5. Rear egress door swings in and should swing out. It should have an approved lock installed. 6. On electric issues provide a scope of work of what is being corrected. It shall be shown on the plan. 7. Ensure w h the changes there is proper emergency /exit lighting. 1 %s� KERRY : ' ET , FIRE MARSHAL ** *Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. TRANSACTION REPORT P.oi /ol , APR /22/2009/WED 08:37 AM FAX(TX) # DATE START T. RECEIVER COM.TIME PAGE TYPE /NOTE FILE 01 APR /22 08:37AM 97889519 0:00:18 1 OK SG3 0426 Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 • Fire Marshal Bus (813) 780 -0041 Kerry Barnett Fax (813) 780 -0044 E -mail: kbamett c@fire.zephyrhills.fl.us Plan Review #: 10 -036 Project: Interior Renovation Number of Pages: 4 April 21, 2010 • I have received and reviewed the plan for the renovation located at 38424 5 Ave and have rejected it due to the comments listed below. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. There has been no fees assessed at this time and fees will be assessed upon an approved review. 1. A floor plan is needed to show overall layout and location of issues being corrected. 2. Opening in wall that is being closed in needs better detail. UL number listed on the attached sheet providing ratings shows 2 X 4 studs not 2 X 6 studs, It also shows 5/8" Type "X" on both sides but that is not shown on the detail. 3. Provide UL details of # 1479 and 2079 mentioned on drawn plan for penetrations. 4. There is no mention of the loft. This needs to be calculated for load capacity per square foot to ensure it meets specifications. As it is constructed now the head height is below the requirement and the stairs do not meet code. It is recommended to just remove the loft. 5. Rear egress door swings in and should swing out. It should have an approved lock installed. 6. On electric issues provide a scope of work of what is being corrected. It shall • be shown on the plan. 7. Ensure the changes there is proper emergency /exit lighting. — �,�1` KERRY f3 • E FIRE MARSHAL I-iA.L * **please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site • inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure . to be in compliance with all applicable NFPA codes and local ordinances. I -7-'• i ''41'. A / ',. r4f -- n r ! \ ( fi r' . Q o) � r 3 CJ) ) t u\ - --, — -7 At --,;;') J a r --� 1 V 0 '. - ' O l tt I - s P le. ", NS C i '' i 2D , r o REV3€w DAT " . : • r F • vRH i-S 4 PLANS EXAMINER___- L',;; i ,, i 'r11'L v.'11:11 ALL c RI ;v[l NO CC Dk k :LOR1UAblilLDT-' °':i C oDE I alo. \Al, EL CTla CODE AV.J r;17y OF LIT1-1\0.),F111.1.S ORDINANCE • QUICK SELECTOR FOR FIRE AND SOUND RATED SYSTEMS Gypsum Plaster Flreproof's° Column (10WF49 or heavier) (CAD FILE NAME GOLDB.omG OR GOLOB.oxfl No. Fire Rating Ref. Design No. Description STC Test No. 1 1 hr. BMS 92 -Table 40 3/4' (19.0 mm) gypsum plaster, 1:3 sand scratch, 1:3 None None GA CM 1300 sand brown on metal lath. 2 2 hr. -; UL X402 1' (25.4 mm) gypsum plaster, 100:2 perlite scratch, None None III GA CM 2320 100:3 polite brown, on self- furring lath. 3 3 hr. /, UL X402 1 3/8' (34.9 mm) gypsum plaster, 100:2 perlite scratch, None None GA CM 3310 100:3 periite brown, on self - furring lath. 4 4 hr. — -- -� UL X402 13/4' (44.5 mm) gypsum plaster, 100:2 periite scratch, None None GA CM 4410 100:3 perllte brown, on self- furring lath. _mo Gypsum Plaster Fireproofing Beams (8WF24 or heavier) (CAD FILE NAME GOLDC.DWG OR GOLDC.DXF) 1 2 hr. UL R4197-1 1 1/8" (28.6 mm) gypsum plaster, 10021/2 periite scratch None None GA BM 2221 coat, 100:2 1/2 per elite brown coat on self -fumng lath. 2 3 hr. UL R4197-1 1 1/4' (38.1 mm) wp.um plaster, 1002 1/2 pertite scratch None None sangriammg mosinewom GA BM 3110 coat, 100:21/2 periite brown coat on self-furring lath. Veneer Piaster Partitions -Wood Framing (coo FILE NAME GOLDE.DWG OR GOLDO.DXF) No. Fire Rating Ref. Design No. Description STC Test No. SINGLE LAYER 1 1 hr. = U. of Cal. E.S. 6727 3/32" (2.4 mm) Veneer Plaster applied to 1/2' (12.7 mm) 34 NGC 2161 Fire - Shield C Kal -Kore nailed to both sides of wood studs 16' o.c. (406 mm). Veneer Plaster Partitions -Steel Framing (CAD FILE NAME GOLDE.DWG OR GOLOE.DxF) SINGLE LAYER -- 2 1/2' (63.5 mm) STUDS 1 11w. -s. U. of Cal. E.S. 6892 3/32' (2.4 mm) Veneer Plaster applied to 1/2" (12.7 mm) 42 est. Fire -Shield C Kal-Kore on both sides of 21/2'63.5 mm) steel studs 24' o.c. (610 nun) with 1" (25.4 mm) screws 12" o.c. (t44 mm) and 9' o.c. (229 mm) along edges. Studs 16 o.c. (406 mm) preferred method. For additional Kal-Kore Fire and Sound rated systems reference gypsum wallboard systems. Gypsum Wallboard Partitions -Wood Framing (load- bearing) (cAO FILE NAME GOLDH.OWG OR GOLDH.DXF) No. Fire Rating Ref. Design No. Description STC Test No. SINGLE LAVER FIRE — SOUND 1 45 min. UL U317 1/2" (12.7 mm) Fire - Shield C Gypsum Wallboard or 1/2' 34 NGC 2161 (12.7 mm) Fire - Shield C Kal -Kore plaster base nailed both sides 2 x 4 (38 mm x 89 mm) studs, 16" o.c. (406 mm). 2 1 hr. UL U305 5/8' (15.9 mm) Fire - Shield Gypsum Wallboard, 5/8" (15.9 mm) 35 NGC 2403 GA WP 3605 Fire - Shield Kal -Kore plaster base or 5/8' (15.9 mm) Fire - Shield MR Board nailed both sides 2 x 4 (38 mm x 89 mm) wood studs, 16" o.c. (406 mm). 10 NATIONAL GYPSUM QUICK SELECTOR/GENERAL REFERENCE QUICK SELECTOR FOR FIRE AND SOUND RATED SYSTEMS Gypsum Plaster Fireproofing Colman: (18WF4S or heavier) (CAD FlLE NAME Gomm OR GOIDe.DxF) No. Fire Rating Ref. Design No. Description STC Tbat No. 1 1 hr. BMS 92 -Table 40 3/4' 1(9.0 mm) gypsum plaster, 1:3 sand scratch, 1:3 None None GA CM 1300 sand brarm on metal lath. 2 2 hr. life UL X402 1" (25.4 mm) gypsum plaster, 100:2 partite scratch, None None GA CM 2320 100:3 perlite brown, on self- furring Iath. 3 3 hr. o UL X402 1 3/6' (34.9 mm) gypsum plaster, 100:2 perlite scratch, None None - GA CM 3310 100:3 perlite brown, on self- furring Iath. 4 4 hr. w,— UL X402 1 3/4' (44.5 mm) gypsum plaster, 100:2 perlite scratch, None None GA CM 4410 100:3 perlite brown, on self- furring Iath. Gypsum Plaster Fireproofing Beams (8WF24 or heavier) (CAD FILE NAME GoLDC.DwG on GOLDC.DXF) 1 2 hr. Kagrinmauganiamx UL R4197 -1 1 1/8' (28.6 mm) gypsum plaster, 100 perlite scratch None None milinemameit GA BM 2221 coat, 100:21/2 perlite brown coat on self - furring lath. 2 3 hr. UL R4197 -1 1 1/4' (38.1 mm) gptwn plaster, 100:2 1/2 perlite scratch None None monenommen GA BM 3110 coat, 100:2 1/2 perlite brown coat on self- furring lath. 1 1 Veneer Plaster Partitions -Wood Framing (CAD FILE NAME GDLDD.DWG OR GoLDO.DxF) No. Fire Rating Ref. Design No. Description STC Teat No. SINGLE LAYER 1 1 hr. U. of Cal. E.S. 6727 3/32' (2.4 mm) Veneer Plaster applied to 1/2' (12.7 mm) 34 NGC 2161 Fire - Shield C Kal -Kore nailed to both sides of wood studs 16" o.c. (406 mm). Veneer Plaster Partitions -Steel Framing (coo FILE NAME GoLDE.Dwc oR GOLDE.DxF) SINGLE LAVER — 21/2' (63.5 mm) STUDS 1 1M. U. of Cal. E.S. 6892 3/32' (2.4 mm) Veneer Plaster applied to 1/2' (12.7 mm) 42 est. • ! ... Fire- Shield C Kai -Kore on both sides of 21/2'63.5 mm) steel studs 24` o.c. (610 mm) with 1' (25.4 mm) screws 12' o.c. (144 mm) and 9' o.c. (229 mm) along edges. Studs 16 o.c. (406 mm) preferred method. For additional Kal -Kore Fire and Sound rated systems reference gypsum wallboard systems. Gypsum Wallboard Partitions -Wood Framing (toad - bearing) (CAD FILE NAME GOL)H.DWG OR GOLDH.DXF) No. Fire Rating Ref. Design No. Description STC Test No. SINGLE LAYER FIRE – SOUND 1 45 min. U L U317 1/2` (12.7 mm) Fire - Shield C Gypsum Wallboard or 1/2' 34 NGC 2161 (12.7 mm) Fire- Shield C Kal -Kore plaster base nailed both sides 2 x 4 (38 mm x 89 mm) studs, 16' o.c. (406 mm). 2 1 hr. il=== UL U305 5/8' (15.9 mm) Fire - Shield Gypsum Wallboard, 5/8' (15.9 mm) 35 NGC 2403 GA WP 3605 Fire - Shield Kal -Kore plaster base or 5/8' (15.9 mm) Fire- Shield MR Board nailed both sides 2 x 4 (38 mm x 89 mm) wood studs, 16' o.c. (406 mm). 10 NATIONAL GYPSUM QUICK SELECTOR/GENERAL REFERENCE XVi 1-i f / r / , p U q VJ City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: af—vl 51 Date Received: `i -/ ( - /0 Site: S f 2 Lf ' A4d Permit Type: C 10 S ( A SQT'C'A wty - G) e%d ' ict Approved w /no comments: Approved w /the below comments: ❑ Denied w /the below comments: ❑ This comments et s - b- ept with the permit and /or plans. Kalvin S itzer — ' . s Examiner Date Contractor and/or Homeowner (Required when comments are present) Jacqueline _Boges From: Jacqueline Boges Sent: Monday, May 03, 2010 3:11 PM To: Kerry Barnett Subject: revision plan in your box Kerry placed in your box revision plans from sunstate for Judy's boutique 38424 5 Ave . Jackie Boges Code Support Specialist ext. 35 r . ,. . , _ . '' nrrN 7 BYZEPHT'.x rY.t.,' t)rF'►rt� v Date._._._._ ._ ..... SUBMr BY ZEPl Date: irviewer: SUBMITTED PLAN(S) VE BEEN REVIEW BY • • . i MARSHAL'S OFFICE Date: `'�` o B.rviewer: i " ' 1 ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Fire Chief Keith Williams Bus (813)780 -0041 Fax (813)780-0044 FIRE SERVICE USER FEES Occupancy No.: //�� � � Plan No.: /e— 9 � Contractor: ,5 ISvi `(c: G S Business Name: .. Tud ys ,r� v L Billing Address: Business Address: 4,e1/.,- J Business Phone No.: Billing Phone No.: 7c --7 .3x'3 Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES _ INSPECTION FEES _ PERMIT FEE _ FALSE ALARM FEE ill R Site Plan N/C _ Annual N/C _Sprinkler $50 _ 1st Alarm N/C Muni- FamilvicommwciaL . 6 sf _ 1st Re inspection N/C _ Standpipes $50, _ 2nd Alarm N/C inimum Charge $25.00 — 2nd Re- inspection $100 _Fire Pump $50, _ 3rd Alarm N/C ions DBL ^ 3rd Re inspection $250 _ Hoods $50 _4th Alarm $100 _ 4th Re Inspection $500 Fire Alarm $50 _ 5th Alarm $150 _ SPRINKLER SYSTEMS (Business closed until _ LP Gas $50' _ 6th Alarm $200 — 0 - 25 Heads $50 violations corrected) — Natural Gas $50 NON COMPLIANCE $150 26 plus Heads $100 SPRINKLER SYSTEMS _ Fuel Tanks- per tank $50 • STANDPIPE SYSTEM Hydro Undergrounds $45 Sparklers $100 0 Per Riser $50 Hydrostatic Test $65 per system _ Fire Works $500 FIRE PUMP Acceptance Test $45 per system _ Camp Fire $25" Ei Per Pump $100 Hydrant Flow $75 _ Controlled Bum $100 _ FIRE ALARM SYSTEM Hood/Duct $50 0 - 25 Devices $50 FIRE ALARM SYSTEM _ Place of Assembly $50'; Annual 26 plus Devices $100 System Acceptance $50 Fire Protection $25 _ _ _ SUPPRESSION SYSTEMS Recall Acce 550 _ Flammable Application $50 Annual _ Wet $50 OTHER u _ "AC Waste Tire Storage 550 Annual Dry $50 ire Wall/Smoke Wall $15 p er wall _ Generator < KW $100 _ CO2 $50 LP Gas $25 per tank _ Generator >30 KW 150 Other $50 Natural Gas $25 per system _ Bio-Hazard Waste $100 Annual KITCHEN EXHAUST _ _ Fumigation Tenting $50, 0 Hood/Ducts $50 _ Tent 10'x10' or greater $15 per tent — Torch Pot/Applied $50 OTHER _ Fire Pump $45 — Haz. Materials $100; Annual ^ LP Installation per tank $ 50 _ Fire Suppression $30 Fuel Tank Installation $50 System Acceptance (Per Tank) $50 [J Exhaust Hood/Duct $30 ❑ Natural Gas Installation $50 Re - inspection DBL (Per System) (other than annual) Spray Booth $50 Ei Inspection scheduled DBL Id and cancelled less than 24 hours B Construction Insp. N/C Emergency Vehicle Aa $50 FALSE ALARM PLANS TOTAL. `'' INSPECTION TOTAL I 0 PERMIT TOTAL I 1 TOTAL GRAND TOTAL _ ' d r , oz Comments: Date: 610/0 /(j Insrgctor: ie ,Jlti/ri�ti 0 7 Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (813) 780 -0041 Kerry Barnett Fax (813) 780 -0044 E -mail: kbarnett@fire.zephyrhills.fl.us Plan Review #: 10 -043 Project: Interior Remodel Number of Pages: 5 May 4, 2010 I have received and reviewed the plans for the interior remodel (revision) located at 38424 5 Ave and will allow the project to move forward. Please note that this review does not eliminate any further requirements as the project continues moving forward. By receiving permit, contractor acknowledges to comply with the items listed below. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. 1. Remodel shall be conducted in accordance to applicable NFPA codes. 2. Ensure entire loft is removed. 3. Hardware installed on rear door shall be of a single motion type. 4. If no emergency light is located in the rear area change the exit light being installed to a combination exit/emergency light. 5. Ensure there are 2 certified fire extinguishers, front and rear. 6. Ensure rated drywall mud is used. 7. At final, provide a letter that the electric has been checked to be compliant. Inspections Required: 1. Screw inspection for each layer of rated drywall installed. 2. Final ►' Vii' //0 %— KERRY BARNETT, FIRE MARSHAL ** *Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a fmal approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. - BXUV.U303 - Fire Resistance Ratings - ANSUUL ''2b3 rage i or oi . _ ; II I ' A ; BXUV.U303 Fire Resistance Ratings- ANSI /UL 263 pace Bottom Design /System /Construction /Assembly Usage Disclaimer • Authorities Having Jurisdiction should be consulted in ell Cafes as to the pbrticular requirements covering the installation and use of UL Listed or Classified products, equipment, system, devlceis, and materials. • Authorities Having Juriisdietion should be consulted before construction. • Fire resistance assemblies and products are developed by the dealgn submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot aiweys address every construction nuance encountered in the field. • When field Issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product menufecturer noted for the design, Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information Includes specifics concerning alternate materials and alternate methods of construction. • Only products which beer UL's Mark are considered as Classified, Listed, or Recognized. Fire Resistance Ratings - ANSI /UL 263 ee General information for Fire Resistance Ra}tinnq - ANSI /US. 263 SUBMITTED PLAN(S) HAVE BEEN REVIEWS!' BY ZEPHYRHI 1 ' SHAL'S OFFICE Design No. U303 DMZ: ��� .-- Ass ?Y. January 21, 2030 WCT: _ �.— Bearing Wall Rating —, 1 Mr Load Rastrtcted Mr Canadian Applications — See Guide BXUV7 PC-)\.. CC:i1N.,,,,,,IL - rae gs 1141141_ - ,, : .-/ 0 r • @TS: ; 1. Wood Studs — Nom 2 by 4 in. spaced 16 in. OC, effectively cross - braced. 2. Gypturn board* — 5/8 in. thick, with square or tapered edges, applied verticaiiy or horizontally with vertical Joints centered over studs, Horizontal Joints need not be backed by framing. Fastened to studs and pietes With 1 -7/8 in. long bd cement coated nails spaced 7 in. OC or with 1 -7/8 In. long Type S screws spaced 8 in. OC, or 1 -1/4 in. long Type W ctlstee thread gypsum panel steel screws spaced a max 8 in. OC, with last srcrew 1 in. from edge or board. 34 in, widths ap horizontally. , `' CANADIAN GYPSUM COMPANY — Types AR, C, 1P-AR, IP -X1, IP -X2, IPC -AR, SCX, WRC, WRX, UNITED STATES GYPSUM CO — Types AR, C, FRX-G, 1P -AR, IP -X1, IP -X2, IPC -AR, SCX, WRC or WRX. http n 1 . j:aba 1 7 c o . 0 nln/cgi- bin /XYV /template /LISEX c a c i 7 ,� � i a - I N a No n R N �`tml ?j j A c : 7 . 1 . . 0 1 0 Z L r l tl v BXUV.U404 - Fire Resistance Ratings - ANSI/UL 4bJ ragc .3 01 3. CementitioUa Backer Units"' — 1/2 In. or 5/8 in. thick, applied vertically or horizontally with vertical joints centered over studs. Fastened to studs and runners with corrosion resistant, Chamfered, ribbed wafer head screws with a minimum head diameter of .400 inch. For nonbearing systems, fastened to studs and bottom runners with the uppermost screws placed 1/2 in. to 2 In. below the bottom edge of the leg of the top runner. Horizontal joints need not be backed by framing. 1 Hr System - Screws shall be min 1 -1/4 in. long and spaced a max of 8 in. OC. Alt vertical joints staggered one stud cavity from gypsum board vertical joints on the opposite side of studs. Horizontal edge joints and horizontal butt joints on opposite sides of studs need not be staggered. 2 -Hr System - For the base layer in Configuration B, the screws shell be min 1.1/4 In. long and spaced a may of 12 in. OC. For the face layers, screws shall be 1 -5/8 in. long and spaced a max of 8 In. OC. All race layer joints offset min 12 in. from underlying base layer Joints. )olnts in either layer need not be staggered from joints oh the opposite side of the wail. UNITED STATES GYPSUM CO — DUROCK Exterior Cement Board, or DUROCK Brand Cement Board. 4. Batts and Blankets" — Min 3 in. thick miner!! wool insulation batts, friction fitted between studs . THERMAFIBER INC — Type SAFB. 5. Gypsum Boards -- 5/8 In. thick, with square or tapered edges, applied vertically Or horizontally with vertical joints centered over studs. Horizontal joints need not be backed by framing. Fastened with Type 5 -12 screws. 1 -Hr System - For vertical application, fastened to studs and runners with 1 in. long screws spaced max 8 In. OC at vertical edges and spaced max 12 in. OC In the field. For horizontal application, fastened to studs and runners with 1 In. long screws spaced max 8 In. OC. Vertical joints staggered one stud cavity from cement board vertical Joints on opposite side of studs. Horizontal edge Joints and horizontal butt joints on opposite sides of studs need not be staggered. 2 -Hr System - Base layer with an overlying gypsum board face layer, fastened with 1 In, long screws spaced max 16 In. OC to studs and runners. Base layer with an overlying cement board face layer, fastened with 1 In. long screws spaced max 12 in. OC to studs and runners. Face layers fastened with 1 -5/8 In. long screws spaced max 16 In. OC to studs and runners with screws offset 8 in. from face layer screws. Face layer joints offset min 12 in. from base layer joints. Joints In either layer need not be staggered from joints on the opposite side of the wall. When used in widths other than 413 in., gypsum panels to be Installed horizontally. CANADIAN GYPSUM COMPANY — Types AR, C, IP -AR, IP -X1, IP -X2, IPC -AR, SCX, SHX, WRC or WRX. UNITED STATES GYPSUM CO — Type AR, C, fRX -G, IP -AR, IP -X1, IP -X2, IPC -AR, SCX, SHX, WRC, WRX, USGX (Joint tape and compound, Items 6 and 7, optional for use with Type USGX) USG MEXICO 15 A DE C V — Types AR, C, IP-AR, IP -X1, IP -X2, IPC -AR, SCX, SHX, WRC, WRX. SA. Gypsum Board* — (As an alternate to Ram 5 may be used as the base layer on one or both Sides of wall, For direct attachment only) - Nom 5/8 in. thick lead backed gypsum panels with beveled, square or tapered edges, applied vertically. Vertical joints centered over studs and staggered min 1 stud cavity on opposite sides of studs. Wallboard secured to studs with 1-1/4 in. lohg Type S -12 steel screws spaced 8 in. OC at perimeter and 12 in. OC in the field. RAY -BAR ENGINEERING CORP — Type R8 -LBG 5B. Gypsum Board" — (As an alternate to Rem 5 or SA may be used as Inc base layer on one or both sides of wall, For direct attachment only). Nominal 5/8 In. thick lead backed gypsum panels with beveled, square or tapered edges, applied vertically. Vertical joints centered over studs end staggered min 1 stud cavity on opposite sides of studs. Wallboard secured to studs with 1 -1/4 In, long Type S -12 (or #6 by 1-1 /4 in. long bugle head fine driller) steel screws spaced 8 In. OC at perimeter and 12 in. OC in the field. NEW ENGLAND LEAD BURNING CO INC, DBA NELCO — Nalco 6. Joints — Covered with glass fiber mesh tape and latex modified Portland cement mortar or basecoat, or Type I organic adhesive, 7. Joints — When tapered edge gypsum board is used, face layer joints covered with Joint compound and paper tape. As an alternate, gypsum veneer plaster may be applied to the entire surface of Classified veneer baseboard with joints reinforced. When square -edge gypsum board is used, treatment orjolnts is optional. 8. Vapor Retarder, Water serrier or Weather Resistive Barrier — (Optional — Not shown) — As required. 9. Lead Batten Strips — (Not Shown, Por use With Item SA) - Lead Patten strips, min 1 -3/2 In. wide, max 10 ft long with a max thickness of 0.125 ih. Strips placed on Inc interior face of studs and attached from the exterior face of the stud with two 1 in. long Type 5 -12 pan head steel screws, one at the top of Inc strip and one at the bottom orthe strip. Lead batten strips to have a purity of 99.9% meeting the Federal specification QQ- L -201f, Grade "C ". Lead batten strips required behind httpj; " bin /XW /template /LYSEXTRSI?1 a31N; NOS1198 33t ? Wd8S Zl O10Z LZ 'ad BXUV.U404 - Fire Resistance Ratings - ANSI/UL 2b3 rage u1 �+ vertical joints of lead backed gypsum wallboard (Item 5A) and optional at remaining stud locations. Required behind vertical joints. 10. Lead Discs or Tabs — (Not Shown, for use With Item 5A) - Used In lieu of or in addition to the lead batten strips (Item 9) or optional et other locations - Max 3/4 in. diem by max 0.125 in. Mick Teed discs compression fitted or adhered over steel screw heeds or max 112 in. by 1 - 1/ 4 in. by max 0.125 in. thick lead tabs placed on gYpsum boards (Item 5A) underneath screw locations prior to the inStabatton of the screws. Lead discs or tabs to have a puny of 99.9 meeting the Federal specification QQ -L -2011, Grade "C ". I]. Lead Batten Stripe — (Not Shown, For Use With Item 5B) Lead batten strips, 2 in. wide, max 10 ft long with a max thickness of 0.142 in. Strips placed on the face of studs and attached to the stud wltn two min. 1 in. long rnin. Type 5 -9 pan head steel screws, one at the top of the strip and one at the bottom of the strip or with one min. 1 in. long min. Type s pan head steel screw at the top of the strip. Lead batten strips to have a purity of 99.9% meeting Me Federal specification QQ•L -201f, Grade "C ". Lead batten strips required behind vertical joints of lead backed gypsum wallboard (Item 59) and optional at remaining stud locations. 12. Lead Tabs — (Not Shown, For Use With Item SB) 2 in. wide, 5 In. long with a max thickness of 0.142 in. Tabs friction - flt around front face of stud, the stud folded back flange, and the back fate of the stud. Tabs required at each location where a screw (that secures the gypsum boards, Item 58) will penetrate the steel Stud. Lead tabs to have a purity of 99.9% meeting Ma Federal specification 0Q- L -201f, Grade "C ", Lead tabs may be held In place with standard adhesive tape if necessary. "Bearing the UL ClassIflcatiorl Mark Lest undateg on 2009.10 -16 • Ouestions? Print this peat Notice of Disclaimer Page Top Convvrktht 2010 Underwriters Lnhnratedes Inc.® The appearance of a company's name or product in this database does not In itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered Under UL's Foltow•Up SeMite. Always look for the Mark on the product. UL permits the reproduction of the material contained In the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and /or Listings (files) must be presented m their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format; "Copyright te 2010 Underwrtters Laboratories Inc. ®" An inne;.ananni argaAitaiion warKIng fcr n aster world with integrity, precision Ina knowindge le 4 i p 1 � http "'.caba � •oNn/cgi- bin/XYV/ template /LISEX I �d�31N3 NOSf1 • • • 'it l? • • - • . l . . 0 o M LZ " ' dd -Nev‘ L4 tr-c-sz-S c..:(\c),4\q • ■• N CC) k.)." 1 -7 ‹) AczcZWs:A,3 N(N rY V3t, ra_c J oy r .P s a ti N - 1 j S a --'1 . r 1 Ti ,G a O -4 S ti W y `� y A r- t I Q a n 34 x )a j b h ° o 1 r ■ ti 1 — 'D '# k k \ N %it , c), c Print Date: 4/1/2010 2:43:21PM :$PNYAMII� � :t �,�.� �` � ,. � � � � I� �.�� 13� , � 1 t � aa'� �� ;3s I '� ,,, i 1i F Commercial Activity Date: 4/1/2010 1:05:30PM t ; 5 R .f' C e , , Zephyrhills Fire Rescue ctivity Number: 1-171-10-0342 FLORIDA , Fire Prevention Bureau Activity Cause: Request 6907 Dairy Rd Inspector Name. Hector Noyes Zephyrhills, FL 33542 Inspector Phone: Phone: 813 -780 -0041 p Fax: 813- 780 -0044 Party: Occupancy Type: Mercantile Judy's Boutigue & Consignment Property Use: Specialty Shop (000578) Total Violation: 0 38424 5TH AVE Corrected Violation: 0 ZEPHYRHILLS, FL 33542 Hours: 1.17 Total Fees: $ 0.00 erg .. 5 •. �! �i zs , ` , .,' r 3 E - 3 � # � i 1 Ref. Number: NFPA101 (2006) Florida Fire Prevention (2007) 36.2.4.3 Number of Exits. A single means of egress shall be permitted in a Class C mercantile occupancy, provided that the travel distance to the exit or to a mall does not exceed 23 m (75 ft). 2 Ref. Number: NFPA101 (2006) Florida Fire Prevention (2007) 36.3.5.3 Extinguishment Requirements. Portable fire extinguishers shall be provided in all mercantile occupancies in accordance with 9.7.4.1. Comment: 2A -10 BC shall be provided 3 Ref. Number: NFPA 1 (2006) Florida Fire Prevention (2007) 10.10.1 Smoking. Where smoking is considered a fire hazard, the AHJ shall be authorized to order the owner in writing to post "No Smoking" signs in conspicuous, designated locations where smoking is prohibited. Comment: No Smoking signs shall be posted. 4 Ref. Number: NFPA 1 (2006) Florida Fire Prevention (2007) 10.19.6 Attic, Under - Floor, and Concealed Spaces. Attic, under -floor, and concealed spaces used for storage of combustible materials shall comply with the protection from hazards requirements for storage rooms in NFPA 101. 5 Ref. Number: NFPA 1 (2006) Florida Fire Prevention (2007) 10.19.3.1 Ceiling Clearance. Storage shall be maintained 2 ft (610 mm) or more from the ceiling in nonsprinklered areas of buildings. Comment: Both sales floor and storage room apply. 6 Ref. Number: NFPA 1 (2006) Florida Fire Prevention (2007) 11.1.3 Electrical Fire Safety. Permanent wiring shall be installed and maintained in accordance with NFPA 70. Comment: All areas where there is exposed electrical high voltage wiring must be inclosed in an approved raceway. If dead, wiring must be tagged "Abandoned in Place" 7 Ref. Number: NFPA 1 (2006) Florida Fire Prevention (2007) 11.1.5 Electrical Fire Safety. Extension cords shall not be used as a substitute for permanent wiring. 8 Ref. Number: NFPA 1 (2006) Florida Fire Prevention (2007) 11.1.5.2.3 Relocatable Power Taps. Relocatable power tap cords shall not extend through walls, ceilings, or floors; under doors or floor coverings; or be subject to environmental or physical damage. Comment: This pertains to extension cords. Remember extension cords are for temporary use. 9 Ref. Number: NFPA 1 (2006) Florida Fire Prevention (2007) 14.14.4* Power Source. Where emergency lighting facilities are required by the applicable provisions of Chapter 11 through Chapter 42 of NFPA 101 for individual occupancies, the signs, other than approved self - luminous signs and listed photoluminescent signs in accordance with 14.14.6.4.2, shall be illuminated by the emergency lighting facilities. The level of illumination of the signs shall be in accordance with 14.14.6.3 for the required emergency lighting duration as specified in 14.14.6.4. However, the level of illumination shall be permitted to decline to 60 percent at the end of the emergency lighting duration. [101:7.10.4] Comment: Remove exit/emergency light located at the rear door and install at street exit. Page 1 of 2