Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
10-10588
CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780 -0020 10588 BUILDING PERMIT Permit Number: 10588 Address: 7928 GAL BLVD Permit Type: COMMERCIAL . ZEPHYRHILLS, FL. Class of Work: ADD /ALT COMMERCIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: ZEPHYR COMMONS Est. Value: Parcel Number: 35- 25 -21- 0130 - 00000 -0140 Improv. Cost: 79,764.00 , 7, 17. . ,,.r ; ,;,;: Date Issued: 6/16/2010 Name: ZEPHYR COMMONS 'Lc Total Fees: 9,730.00 Address: 3629 MADACA LANE Amount Paid: 4,558.60 TAMPA FL 33618 Date Paid: 6/16/2010 Phone: (813)933 -0629 Work Desc: 2ND BUILD OUT GREAT CLIPS 1200 SQ FT FM LIN - 1 LIN - •N R BUILD N 40800 S R •NN TI• • ME 1,608.00 KW MORROW & SONS ELECTRIC INC ELECTRICAL FEE 90.00 WATER CONNECTION COMMERC 512.80 DYSER PLUMBING CO PLUMBING FEE 60.00 TRAFFIC IMPACT FEE 99% 6,826.25 ABSOLUTE AIR SYSTEMS INC MECHANICAL FEE 42.00 TRAFFIC IMPACT FEE 1% 68.95 RADON 12.00 FIRE PLAN REVIEW FEES 72.00 FIRE INSPECTION FEES 30.00 ,V.410--/-30'16 ,1' "44/ F, • / v ' cp - �S�,o �, �� ► !' A 1-2t0 " ► ` 1►', rig/. •...,- - HPL MB I ®n �` IN ULA •• R 2NDR•U �J TI• EILIN FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE -METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE -SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to any one of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." ii...go or 44 /Iii• 'eA. C TRACTOR SIGNATURE PERMIT OFFI FR PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE - REQUIRED PROTECT CARD FROM WEATHER •••', ft.. le • e , (:) .1. • I 1 !, 3 . • • , • • r , ;•• Jacqueline Boges From: Kerry Barnett Sent: Tuesday, July 27, 2010 2:43 PM To: Jacqueline Boges Subject: RE: FM LINER CALLED IN FOR INSPECTION FOR THE GREAT CLIPS FINAL FOR WEDNESDAY 28TH Thanks, I scheduled it for tomorrow afternoon. From: Jacqueline Boges Sent: Tuesday, July 27, 2010 11:12 AM To: Kerry Barnett Subject: FM LINER CALLED IN FOR INSPECTION FOR THE GREAT CLIPS FINAL FOR WEDNESDAY 28TH Jackie Boges Code Support Specialist ext. 35 p effiv 4 07 2-1 0 6/16/20 ] 1O:25 AM cR ` - \� ---'—_ Tot,Th 4,5�J.6O a3sn; 0.0E Check: 4�53 o4#2O266 :Jp#105B8 _ ^ 6O ck#2Cr�/ ~~ apllD588 Custoaer 0: ' Cash1E,r/ bobbiE 7928 GALL BLVD 1200 SQ FT - GREAT CLIPS 2ND BUILDOUT PERMIT # 10588 SQ. FEET PRICE MAIN OR LIVING: 1,200 $ 66.47 TYPE V $114.47 - $48.00 OTHER AREA UNDER ROOF: - $ 91.00 OTHER: - $ - VALUATION $ 79,764.00 FEE SHEET $ 400.00 ADDRESS DRIVEWAY lig BUILDING: $ 408.00 / ELECTRICAL: $ 90.00 ur 1 i ' PLUMBING: $ 60.00 ✓ ' MECHANICAL: $ 42.00 Ls/ v l! , (p �` SUB -TOTAL $ 600.00 . ., RADON: $ 12.00 f P t TOTAL_ $ 612.00 SEWER: $ 1,608.00 L/' WATER: $ 512.80 ✓ . ` IRRIGATION: $ - �G TOTAL: $ 2,120.80 11 I WATER METER: - MASTER METER IRRIGATION METER $ I N/A FIRE DEPARTMENT FEES PLANS TOTAL: $ 72.00 ./ — �^ ` INSPECTION TOTAL: $ 30.00 ✓ 11 PERMIT TOTAL � `� �, / TOTAL: $ 102.00 V`"" PUBLIC SAFETY IMPACT FEES POLICE FIRE 5% $ - TOTAL: $ - PD DURING SHELL I SUB -TOTAL $ 2,834.80I I PARK IMPACT FEES $ - I N/A SIF'S: $ - C �^'_ _ 6 / 6 . () 100.0% $ - ( Y` � 5 $ 9 ° � a 1.0% $ - ` TOTAL: $ - N/A / r 7'67/6 R 38D T I F 'S . $ 6,895.20 5746 P' R 1000 SQ. FT t 99% $ _ ,.....% 6,826.25 ,., 1% Arille 68.95 7 _ , _ "a . - ..9.0' ' PAY $1723.80 + $2834.80 = $4558.60 r' TOTAL: '71.'9,730.00 BALANCE DUE B4 PRE METER- $5,171.40 • 7928 GALL BLVD 1200 SQ FT - GREAT CLIPS 2ND BUILDOUT PERMIT # 10588 SQ. FEET PRICE MAIN OR LIVING: 1,200 $ 66.47 TYPE V $114.47 - $48.00 OTHER AREA UNDER ROOF: - $ 91.00 OTHER: - $ - VALUATION $ 79,764.00 FEE SHEET $ 400.00 ADDRESS DRIVEWAY BUILDING: $ 408.00 ELECTRICAL: $ 90.00 PLUMBING: $ 60.00 MECHANICAL: $ 42.00 SUB -TOTAL $ 600.00 RADON: $ 12.00 TOTAL $ 612.00 SEWER: $ 1,608.00 WATER: $ 512.80 IRRIGATION: $ - TOTAL: $ 2,120.80 WATER METER: - IRRIGATION METER $ I N/A MASTER METER FIRE DEPARTMENT FEES PLANS TOTAL: $ 72.00 INSPECTION TOTAL: $ 30.00 PERMIT TOTAL TOTAL: $ 102.00 PUBLIC SAFETY IMPACT FEES POLICE FIRE 5% $ - TOTAL: $ - PD DURING SHELL SUB -TOTAL $ 2,834.80I PARK IMPACT FEES $ - I N/A SIF'S: $ - 100.0% $ - 1.0% $ - TOTAL: $ - N/A T I F 'S : $ 6,895.20 5746 PER 1000 SQ. FT 99% $ 6,826.25 1%_ $ 68.95 TOTAL: $ 9,730.00I L E G A L D E S C R I P T I O N : ASSESSED IN SECTION 35, TOWNSHIP 25 SOUTH, RANGE 21 EAST, PASCO COUNTY, FLORIDA ZEPHYR COMMONS PHASE 1 PB 65 PG 132 LOT 14 SUBJECT TO & TOGETHER WITH PARKING EASEMENT AGREEMENT PER OR 8046 PG 413 OR 7413 PG 626 IIIIII VIII II1II VIII VIII 11111 VIII VIII II1II V III IIII IIII NOTICE OF COMMENCEMENT 2010085405 Permit No. Rcpt :1310602 Rec: 10.00 DS: 0.00 IT: 0.00 06/16/10 K. Garcia, Dpty Clerk Property Identification No. 35' 2.5. 21 - 0 130 • 00000 - 0 1 4 40 THE UNDERSIGNED her give informs you that the improvement will b made to certain real property, and in accordance with Section 713.13 of the Florida Statutes, the following information is provided in this NOTICE OF COMMENCEMENT. • 1.Description of property (legal description:) Q, � U E. a) Street Address: 7' Z $ I f ki d . Zc f he r Ili 1 ` S , �L L. 2.General description of improvements: it t b u i l d ou 0 . . 3.Owner Information a) Name and address: W O j n e Bunn 792 a alli1 151 ucl . Z ep k r vials , R. b) Name and address of fee simple titleholder (if other than owner) c) Interest in property 43wne busi ntSs 4.Contractor information a) Name and address: t` . f1 . L i rl { r Co n- E ru C- t o A 2410 ,. Q. Sµ . I I t {-Z i CL 33S-5 4. b) Telephone No.: 813, 4 4Q • 0 4 Z g Fax No. (Opt.) 5.Surety Information a) Name and address: :; b) Amount of Bond: • c) Telephone No.:- Fax No. (Opt.) 6.Lender . a) Name and address: Phone No; 7. Identity of person within the State of Florida designated by owner upon whom notices or other documents may be served: a) Name and address: To hr Liytty 2414o .5.12...5q #) I I.I +Z, cL, 3 335 1 b) Telephone No.:. A13. 4 4. -5S09 _ Fax No. (Opt.) 8.In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.13 (1)(b), Florida Statutes: a) Name and address: b) Telephone No.: Fax No. (Opt.) 9.Expiration date of Notice of Commencement (the expiration date is one year from the date of recording unless a different date is specified): 6.16 • I WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND PO TED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONS/ T YOUR LENDER OR AN ATTORNEY BEFORE • COMMENCING WORK OR RECORDING YOUR NOTICE / • ' ' NCEMENT. STATE OF FLORIDA COUNTY OF PASCO `r . SANWra of Owner or wn { uthor" Officer irectodPertner/Manager Print N / / am 7 Mr The foregoing instrument was acicnowledged before me this ` 6 day of Wye , 20 % fl , by itSt14..r✓Y ' 411:-.(P Ser ra as O Nt.NtJ>Glr.. _ (type of authority, e.g. officer, trustee, attorney in fact) for (name of party on behalf of . is 1 . '' I I ent • as exec ed.: � s , / Personally Known OR Produced Identification `� Notary Signatur: / /� , i / L ,' ' ' -/ Type of Identification Produced gag s-Q/ 9- ii4.111%.0 Name (print) ' • MAX K . VS t 1 -1ce Y7" Verification pursuant to Section 92.525, Florida Statutes. Under penalties of . rj ' /l eclare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge anti belief. i / • . ,! �I L FORMSyNOC,rvsd2007 1 R. MARK waarr O ' gnatu of Natural Person Signing Above 4 Commission DD 722666 • ' -�� . ' Expires. December 8, 2011 -' -,• „,„ aondedThmTmy Fain harrm$06- 3eSro1s PAULR S . 0'NE IL,Ph.D.PASCO K & COMPTROLL 06/ 16/10 OR /B01 K 8355 PG 142 T � DA COUNTY OF � 1 O J,.. THIS IS 1 �,E TiF r' THAT THE FQREG FNG IS A TRUE AND CORRECT COPY OF' THE DOCUMNT ON FILE OR CF PUBLIC RECORb IN THISOFFIGE•,, WITN , S MY HAND A OFFICIAL. SEAL THIS T / (PVC DAY OF PAULA S , O' • EIL, C RK & ;OMPTRQLL R , • r . BY At _ _ '.'DEPUTY CLERK ' p PASCO COUNTY, FLORIDA Permit No. M,5 D ate Permitted 6 - O Builder Name /Owner Name 'FM 11 €r- mMs Control # County Parcel No. 35-25-21— 01 30- 0000)0- 0 Ic(.O SubDiv: Z7 y Cr nnons Address /Location "7 9 2-6 c r4 11 (3� Classification/Type of Use Co rvmrvt erc, &L- Pja.rbeec or t�ec>l y TRANSPORTATION IMPACT FEE Rate: 5'7 q ( Sq Ft Unit: / a00 Exempt _ Yes _ No How Determined Impact Fee Amount $ ( 8 q 5 20 Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single- Family Detached House Amount $ /0 0/ - (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt L Yes No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ /OM Exempt _ Yes [ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt _ Yes _ No How Determined Total Amount / 0 //4- RESOURCE FEE ERU TOTAL AMOUNT Prepared By 8D Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence, but simply receipt of a copy of this form, placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY ' I VY FZ f! r Trr„ City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: f-A /?�Y at54 Date Received: D - 9 ,0 Site: 792-5 0A-1l �it4) Permit Type: _4(/ ` W /Q( '(.7 Oa) ' _ ,E_ Approved wino comments: ❑ Approved w /the below comments: Denied w /the below comments: ❑ i ) 41 I F, T, c. (1 C< sL 11 t.e_ t', Akf ord aii r. Ao Ld i I- lam- r) of g i t Ec /LO a® 2) PON I4u It s rinki cs 1 PIA it 1 s c vdly� P � if Ahl 5 ;gi ICLee 3) ill oak 50 ir c' *anJqbl £ei-h ()no gG. No 26 01 fi v.tI EIS cg,ie__(,) ter- z (96 s hdo.6 , This co t s • t s- . 9 e lie with the permit and/or plans. .4/ /" /c L K. in Swi . -r - Pl _ ?f xaminer Date C tractor and/or Homeowner equired when comments are present) !I-13-780-0020 City of Zephyrhills Permit Application Fax - 813-780 -0021 Building Department Date Received Z 4 q - 513o q Phone Contact tor Permittl . 13 Owner's Name , % /rA/ : ' d (.t) Q 1" r Ul A • Owner Phone Number 813 Q3 3 - 0 (D ZQ Owner's Address l 36)2.c? madam I n Tam Pa 1 Owner Phone Number I Fee Simple Titleholder Name 1 Owner Phone Number 1 F Fee Simple Titleholder Address I JOB ADDRESS 1 7 q 2 8 Call Bi ti a, 1 LOT # 1 1 SUBDIVISION 1 PARCEL ID# 1 35-2.5. 2 1. 0130.00000 . 014 0 I (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED Ei NEW CONSTR r ADD /ALT j SIGN Q Q DEMOLISH INSTALL C REPAIR PROPOSED USE 0 SFR 0 COMM imi OTHER J TYPE OF CONSTRUCTION O BLOCK [J FRAME 1 J STEEL n 1 J I DESCRIPTION OF WORK 1 1 n tr ► 0 r 6u '11c1 o L4. 4- C BUILDING SIZE 1 20 f 1!Q o 1 SQ FOOTAGE 1 1 v V 112,4 0 HEIGHT /to r — i V QBUfLDiNG 1 *r 2 5, o I VALUATION OF TOTAL CONSTRUCTION J1ELECTRICAL Is 6,000 J AMP SERVICE PROGRESS ENERGY ® W.R.E,C. =PLUMBING I 614 0 C) I � t , -1�3 S-e kL" MECHANICAL J Ff m 6- 0 $ 5 0 Q VALUATION OF MECHANICAL INSTALLATION � te GAS Q ROOFING Q SPECIALTY MIN OTHER ..- de �' FINISHED FLOOR ELEVATIONS l l FLOOD ZONE AREA EYES NO BUILDER COMPANY 1 r". 1 1 n f r Co nS - I ru C 0 n I SIGNATURE REGISTERED 1 YIN 1 FEE CURREN 1 Y / N 1 Add roe 1 2 41' 4 o S. e. 511 .it I J 1-I Z .�3 SSR 1 License # 1 C CO 112 i 2 EIQNAT RED W COMPANY 1 1 (Y` LA) O(Z12_W O O So K e c E e REGISTERED 1 CO N 1 FEE CURREN 1 Y / N J Address !�s n'1 1"f �- "�C' CC 1 License # I /C /3 ©0 / / ii ii I PLUMBER SIGNATURE I O # COMPANY ( 5 f L G� /u 0.-v,.... -►. ,6IN REGISTERED Y / N 1 FEE CUR �-� 1 Y W 1 Address I 4 13 ` d 4 /e/-4.,, "- / 1 . /,i' 1 L icense d # 1 C p Go / J 9 / / I MECHANICAL .0 COMPANY IA* ,4 a 5 ) 9 5/60.., , � SIGNATURE REGISTERED "' 77 f f N I FEE CURREN i Y/ N 1 Address 137/ zg Koss /K ,41 Z/(1 ?My, License # 1 C Rc.. /xj, I OTHER I COMPANY SIGNATURE REGISTERED Y f N l 1 FEE CURREN 1 Y N I Address 1 License # 1 1111111111111111111111111111111111111111 RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1 ) set of Energy Forms; R-O-W Permit for new construction, • NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed In accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division — Licensing Section at 727 -847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT /UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89 -07 and 90 -07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not Involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water /Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law — Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner ", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S /OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. 1 certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection - Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District - Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers- Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services /Environmental Health Unit - Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency- Asbestos abatement. Federal Aviation Authority- Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V" unless expressly permitted. If the fill material is to be used in Flood Zone "A ", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used In any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to . violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit Is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, thekjob is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF CQMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT (F.S. 1 03) OWNER OR AGENT CONTRACTOR I b ribed n sworn affirmed) bef me this ibed ' to (o r ed) fo Ime this i s/are personally known to me or has /have produced W(7,(44-t-'76) s /are personally known to me has /have produced as identification. as identification. Notary Public / i j _ Notary Public Commission No. Commission No. •� +' " ''•• R. MARK WILLETT R. MARK WILLETT 'g ; " Name of Notary typed, _ e u "'� '"` " '• "' Name of Notary typed, prints c Expires a .. � Pi December 8, 2011 xpires December 8, 2011 •,;, Bonded TAN Troy Fain InsuranceTOro Balled TMu Troy Fan kimono, 601.38S-701g ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Fire Chief Keith Williams Bus (813)780 -0041 Fax (813)780 -0044 FIRE SERVICE USER FEES Occupancy No.: Plan No.: /d - 4040 7 Contractor: 6r/t/ L/ c5i( (44js t Business Name: ,[ Billing Address: 24'I ei $x ' Business Address: #.2.f.-6.4-# Z z _ 3 Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES _ INSPECTION FEES _ PERMIT FEE FALSE ALARM FEE _ Site Plan N/C _ Annual N/C _ Sprinkler $50 — 1st Alarm N/C _ Multi- Family /Commercial .06 sf _ 1s Re- inspection N/C _ Standpipes $50 — 2nd Alarm N/C /21X) (Minimum Charge $25.00 _ 2nd Re- inspection $100 _ Fire Pump $50 _ 3rd Alarm N/C 0 Plan Revisions DBL _ 3rd Re- inspection $250 _ Hoods $50 _ 4th Alarm $100 4th Re- Inspection $500 _ Fire Alarm $50 _ 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until _ LP Gas $50 _ 6th Alarm $200 0 - 25 Heads $50 violations corrected) _ Natural Gas $50 _ NON COMPLIANCE $150 26 plus Heads $100 _ SPRINKLER SYSTEMS _ Fuel Tanks- per tank $50 STANDPIPE SYSTEM _ Hydro Undergrounds $45 _ Sparklers $100 0 Per Riser $50 _ Hydrostatic Test $65 per system _ Fire Works $500 FIRE PUMP _ Acceptance Test $45 per system — Camp Fire $25 0 Per Pump $100 _ Hydrant Flow $75 _ Controlled Burn $100 ^ FIRE ALARM SYSTEM _ Hood /Duct $50 0 - 25 Devices $50 _ FIRE ALARM SYSTEM _ Place of Assembly $50 Annual _ 26 plus Devices $100 _ System Acceptance $50 _ Fire Protection $25 SUPPRESSION SYSTEMS _ Recall Acceptance $50 _ Flammable Application $50 Annual Wet $50 OTHER 7i ^ Waste Tire Storage $50 Annual — _ Dry $50 ire Wall /smoke Wall Ii _ Generator < KW $100 _ CO2 $50 LP Gas . : pe tank _ Generator >30 KW 150 Other $50 Natural Gas $25 per system — Bio -Hazard Waste $100 Annual KITCHEN EXHAUST _ _ Fumigation Tenting $50 0 Hood /Ducts $50 _ Tent 10'x10' or greater $15 per tent — Torch Pot/Applied $50 OTHER _ Fire Pump $45 _ Haz. Materials $100 Annual _ LP Installation per tank $50 _ Fire Suppression $30 _ Fuel Tank Installation $50 _ System Acceptance (Per Tank) $50 _ Exhaust Hood /Duct $30 El Natural Gas Installation $50 _ Re - inspection DBL (Per System) (other than annual) 0 Spray Booth $50 0 Inspection scheduled DBL _ and cancelled less than _ _ 24 hours Construction Insp. N/C — Emergency Vehicle Aci $50 FALSE ALARM PLANS TOTAL m it INSPECTION TOTAL LM r PERMIT TOTAL TOTAL GRAND TOTAL INVAc Comments: Date: /0 /e InsgRctor: /' ---vj 7 Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (813) 780 -0041 Kerry Barnett Fax (813) 780 -0044 E -mail: kbarnett@fire.zephyrhills.fl.us Plan Review #: 10 -067 Project: Secondary Build -out Number of Pages: 7 June 10, 2010 I have received and reviewed the revised plans for the interior build -out located at 7928 Gall Blvd and will allow the project to move forward. Please note that this review does not eliminate any further requirements as the project continues moving forward. By receiving permit, contractor acknowledges to comply with the items listed below. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. 1. The Florida Fire Prevention Code edition is 2007 not what is noted on the plans. Review to ensure the current edition does not affect the build -out. 2. Add emergency light to the restroom(s). 3. No storage will be allowed within 3' of electric panel. 4. No storage within 2 feet of ceiling. 5. Relocate fire extinguisher to front area. Therefore, one will be in fron and one in the rear. Inspections Required: 1. Final . /((, KERRY BA ' T, FIRE MARSHAL ** *Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. City of Zephyrhills Water and Sewer Impact Fee Calculation Land Use Type: Barber or Beauty Shop No of Shampoo Sinks 2 Fees Within City Limits Outside City Limits Water Distribution System $ 512.80 $ 641.00 Wastewater Collection System $ 1,030.73 $ 1,288.41 Wastewater Treatment Plant Capacity $ 577.27 $ 721.59 TOTAL $ 2,120.80 $ 2,651.00 , f:/'n. LNER License # CBCO 11812 (813) 949 -0428 Fax 949 -5447 CONSTRUCTION, 24160 STATE ROAD 54, UNIT 1 e LUTZ, FLORIDA 33559 inc. E -mail: Liner.constructionl @verizon.net GREAT CLIPS 4Kett'Ci 5-a6 " I 7928 GALL BLVD. ZEPHYRHILLS, FLORIDA ATTN. WAYNE BUNN w I (.c, WE OffdwaSEPB CONSTRUCT BUILD -OUT AS FOLLOWS: GENERAL: PROVIDE ENGINEERED PLANS FOR BUILD -OUT. PROVIDE BUILDING PERMIT. Ilv PACT FEES `BY OWNER ". DEMOLITION, REMOVE EXISTING RESTROOM PARTITIONS AND FIXTURES. SAW CUT CONCRETE FOR PLUMBING CONNECTIONS. CONCRETE: PATCH CONCRETE FROM TRENCH WORK. CARPENTRY: CONSTRUCT PARTITIONS PER PLAN (BRING TO ACOUSTICAL CFIT ING). PATCH A.C.T. CEILING FROM RELOCATED RESTROOM DOORS: RELOCATE EXISTING RESTROOM DOOR. PROVIDE TWO (2) Th TERIOR DOORS TO MATCH. 1 WINDOWS: INSTALL ONE -WAY MIRROR AT OFFICE. INTERIOR FINISH: PROVIDE '/" DRYWALL ON NEW PARTITIONS AND REAR WALL, INSULATION: PROVIDE RIGID INSULATION AT REAR WALL. PAINTING: PRIME AND PAINT SPACE AS PER PLAN. MECHANICAL: MODIFY EXISTING HVAC SYSTEM PER PLAN. RELOCATE EXISTING EXHAUST FAN. ELECTRICAL: RELOCATE EXISTING LAY -D4 LIGHTS. PROVIDE SEVEN (7) NEW LAY -IN LIGHTS. PROVIDE ELEVEN (1 I) QUAD OUTLETS. PROVIDE FOUR (4) DATA'PHONE JACKS. PROVIDE FOUR (4) GFI OUTLETS. PROVIDE NINE (9) DUPLEX OUTLETS. INSTALL OWNERS TRACK LIGHTING (3 LOCATIONS). PROVIDE ONE (1) EMERGENCY LIGHT. PROVIDE ONE (1) EXIT LIGHT: PROVIDE SEVEN (7) RECESSED CAN LIGHTS. PROVIDE THREE (3) 3 -WAY SWITCHES. PROVIDE POWER TO WATER HEATER. RELOCATE POWER TO EXHAUST FAN. 2 PROVIDE POWER TO WASHER/DRYER. PLUMBING: RELOCATE PLUMBING CONNECTIONS FOR RELOCATED RESTROOM. PROVIDE 40 GAL. WATER HEATER RELOCATE PLUMBING FIXTURES TO NEW RESTROOM LOCATIONS. PROVIDE UTILITY SINK/FAUCET. PROVIDE WASHER BOX. PROVIDE FLOOR DRAIN. INSTALL OWNERS TWO (2) SHAMPOO SINKS WITH FAUCETS AND HAIR TRAPS. FLOORING: ALL MATERIAL `BY OWNER ". INSTALL OWNERS V.C.T., WOOD LAMINATE, CARPET TILES AND VINYL BASE. MISCFI .LAN'EOUS INSTALL OWNERS GRAPHICS. INSTALL OWNERS STATION DIVIDERS. INSTALL OWNERS MIRRORS. INSTALL OWNERS RECEPTION DESK. INSTALL OWNERS WORK STATIONS /CHAIRS. INSTALL OWNERS MERCHANDISER AND VIDEO WALL. RELOCATE GRAB BARS AND TOILET ACCESSORIES. CLEAN JOB SITE, HAUL DEB1S AND PAY DUMP FEES. CLEAN SPACE FOR USE. PRICE: 538,700.00 G t. t r 3 (ti1G 12 rvLS ' YVn 6.'V,71{ L - -� , .( • F C° P LE c' ti' May '26 10 02:26p Great C.Nps 813-792-0581 P.I s.: , ,n(ro , CH MRS \'1 \1 I {PANI.R:s \fl-.P,CII:0.09M \ \ I) ViDi 0 RI:1 trA, All- (.K.U3 ti \1rZ.$ \ \I) 1r )11 I ACCV.SSIAUES ( L- V JOB Silk }WA. i)OiaN V D P-0 DI.j:\P }Li s, ■L'I...i. -,`, 5} ‘..k C. i'.:31 / ...-•-'"Th / / , A V.C" P.I N.'.. Or ;Pr ■• fi:f In;', ! X71%4 q 1 OA 7.•:!RI C I il ":".. / 3 2- 6 0 R\i, \r:1.4% r H i - .i 1"::“.. i. \ i 't.it (1!; 1 1 )4.11'1 i: TION 1