HomeMy WebLinkAbout10-10661 / CITY OF ZEPHYRHILLS V 5335 - 8TH STREET (813) 780 -0020 10661 COMM EXHAUST HOOD /DUCT PERMIT Permit Number: 10661 Address: 5118 GALL BLVD Permit Type: FIRE COMM EXH HOOD /DUCT ZEPHYRHILLS, FL. Class of Work: FIRE -COM EXH KITCHEN HOOD /DUC1Township: Range: Book: Proposed Use: COMMERCIAL Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 11- 26 -21- 0010 - 07000 -0011 Improv. Cost: 1,000.00 aro. , - Date Issued: Name: FLING GARDENS Total Fees: 130.00 Address: 5118 GALL BLVD Amount Paid: 130.00 ZEPHYRHILLS, FL. 33542 Date Paid: 7/13/2010 Phone: (813)788 -4586 Work Desc: REPAIR EXHAUST DUCTWORK ON RANGE HOOD ,. •UN HE A 1= PE- 1 e 1- -LAN • W E 50.00 FIRE INSPECTION FEES 30.00 6 A a—C — 1 - q — /v FIR LI H T- ina Chapter 633, Florida Statutes, authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees, and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of $100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." dear' Cv0�TS TPGNATURE P IT OFFICER PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT - Fire Marshal Office - 813 - 780 -0041 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813) 780 -0020 10661 COMM EXHAUST HOOD /DUCT PERMIT Permit Number: 10661 Address: 5118 GALL BLVD Permit Type: FIRE COMM EXH HOOD /DUCT ZEPHYRHILLS, FL. Class of Work: FIRE -COM EXH KITCHEN HOOD /DUC'Wownship: Range: Book: Proposed Use: COMMERCIAL Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 11- 26 -21- 0010 - 07000 -0011 Improv. Cost: 1,000.00 x Date Issued: Name: FUNG GARDENS Total Fees: 130.00 Address: 5118 GALL BLVD Amount Paid: ZEPHYRHILLS, FL. 33542 Date Paid: Phone: (813)788 -4586 Work Desc: REPAIR EXHAUST DUCTWORK ON RANGE HOOD •UN Y H AL FIR - IT E 50.00 - PLAN - VIEW 50.00 FIRE INSPECTION FEES 30.00 Nt4. d SZ r. x; : 7t, ; Fl LI - inal Chapter 633, Florida Statutes, authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees, and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of $100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." agar' r CONTRACTOR SIGNATURE P ' IT OFFICER PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT - Fire Marshal Office - 813- 780 -0041 813 - 780 -0020 City of Zephyrhills Permit Applicatio Fax -813- 780 -0021 Building Department Date Received J ' I Phone Contact for Permittin . 502 -- Go • Owner's Name L E C PC7 CIL 4 "f U0PV't -L- Owner Phone Number Owner's Address / 1 ( G4 (L / [,-1 . Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS f 1 fg C4 j / FJ J), LOT # SUBDIVISION PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR 1U ADD /ALT 1 1 SIGN 1 1 1 DEMOLISH INSTALL REPAIR PROPOSED USE n SFR 1 1 COMM 1 1 OTHER TYPE OF CONSTRUCTION n BLOCK In .. FRAME ( 1 STEEL DESCRIPTION OF WORK ? P,?/// 6y46.03r Dc/6 ok.) R.RNG BUILDING SIZE _ SQFQDTA6E HEIGHT BUILDING $ VALUATION OF TOTAL CONSTRUCTION ]ELECTRICAL $ AMP SERVICE I PROGRESS ENERGY n W.R.E.C. 'PLUMBING $ 2 e4 - FiNI;.e ( 2) (c `- - MECHANICAL $ C ov VALUATION OF MECHANICAL INSTALLATION 00 D e 0c t GAS 1 1 ROOFING n SPECIALTY 1 (7- 1 OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA 1 'YES NO BUILDER COMPANY SIGNATURE REGISTERED I Y/ N 1 FEE CURREN I Y/ N 1 Address License # ELECTRICIAN COMPANY SIGNATURE REGISTERED 1 Y/ N I FEE CURREN i Y/ N i Address License # PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURREN i Y/ N i Address License # MECHANICAL COMPANY C 17LUS cast r" M6 SIGNATURE REGISTERED I Y/ N FEE CURREN Y/ N Address License # CScao9yg OTHER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURREN i Y/ N i Address License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R -O -W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions /large projects COMMERCIAL Attach (3) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R -O -W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized if over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey /Footage) Driveways -Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictibns" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division — Licensing Section at 727 -847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT /UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89 -07 and 90 -07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water /Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law — Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner ", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S /OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection - Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District - Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers - Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services /Environmental Health Unit - Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency- Asbestos abatement. Federal Aviation Authority- Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone "V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A ", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT (F.S. 117.03) OWNER OR AGENT CONTRACTOR _ Subscribed and sworn to (or affirmed) before me this Subscribed a s / ° � � , b . ° � <0�1rd by `; ■ Who is /are personally known to me or has/have produced Who is /are personally known to m • has/have produced as identification. _ as identification. ? 7 ii �1 J ubric Notary Public Commission No. Commission No. , BOBBIE S. SWETIAN Nota plat" I p� r u Name of Notary typed, printed or stamped Name of --Jay xplres e. ary 22, 2012 •• ,Rr„ . • Bonded Thu Troy Fain insurance 800-365-7019 Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (813) 780 -0041 Kerry Barnett Fax (813) 780 -0044 E -mail: kbarnett @fire.zephyrhills.fl.us Plan Review #: 10 -074 Project: Exhaust Hood Modification Number of Pages: Packet June 29, 2010 I have received and reviewed the packet for the exhaust hood modification located at 5118 Gall Blvd and will allow the project to move forward. Please note that this review does not eliminate any further requirements as the project continues moving forward. By receiving permit, contractor acknowledges to comply with the items listed below. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. 1. Modification shall be compliant to NFPA 96, current edition. 2. Ensure grease cups and hinge kits on both fans. 3. Ensure both ducts are completed, not just one. Inspections Required: 1. Inspection required after cleaning. 2. Light test required on new welded section. 3. Fina . 1, KE Y : • • ETT, FIRE MARSHAL ** *Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Fire Chief Keith Williams BUS (81 3)780 -004 Fax (813)780; -0044 FIRE SERVICE USER FEES Occupancy No.: J Plan No.: /® b 7 £ 9 Contractor: i j eali Sh� y C'&74 /� Business Name: ,)1, 6 alr.ae Billing Address: 4"3/t. ¶ Business Address: S 1.7 G,- /� Le` � /".1-- S WSZI Business Phone No Billing Phone No.: I 8b- 74z-734:2 Business Fax No.: Billing Fax No:: Contact: Contact: PLAN REVIEW FEES _ INSPECTION FEES PERMIT FEE ! _ FALSE ALARM FEE _ Site Plan N/C _ Annual N/C Sprinkler $5C1 _ 1st Alarm N/C _ Multi Family /Commercial .06 sf 1st Re- inspection N/C Standpipes $501 __ 2nd Alarm N/C (Minimum Charge $25.00 2nd Re- inspection $100 Fire Pump $501 ;3rd Alarm N/C -- 0 Plan Revisions DBL _ 3rd Re- inspection $250 Hoods _14th Alarm $100 4th Re- Inspection $500 Fire Alarm _ 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until LP Gas $50 _6th Alarm $200 0 - 25 Heads $50 violations corrected) Natural Gas $50 NON COMPLIANCE $150 26 plus Heads $100 _ SPRINKLER SYSTEMS Fuel Tanks- per tank $50 STANDPIPE SYSTEM _ Hydro Undergrounds $45 Sparklers $109 I . 0 Per Riser $50 _ Hydrostatic Test $65 per system Fire Works $500 FIRE PUMP _ Acceptance Test $45 par system Camp Fire $251 0 Per Pump $100 Hydrant Flow $75 Controlled Bum $100 FIRE ALARM SYSTEM Hood/Duct $50 — 0 - 25 Devices $50 _ FIRE ALARM SYSTEM Place of Assembly $50 ! Annual 26 plus Devices $100 _ System Acceptance $50 Fire Protection - $25 _ SUPPRESSION SYSTEMS _ Recall Acceptance $5 0 Flammable Application $50 Annual — Wet $50 _ OTHER Waste Tire Storage . $50 Annual Dry $50 _ Fire Wall/Smoke Wall $15 per wall Generator < KW $10 — CO2 $50 _ LP Gas $25 per tank Generator >30 KW 150 _ Other $50 _Natural Gas $25 per system Bio- Hazard Waste $10 Annum KITCHEN EXHAUST Fumigation Tenting $501 pi Hood/ reater $15 9 _ Tent 10'x10' or per tent Torch Pot/Applied $50 OTHER Fire Pump $45 Haz. Materials $100; Annual LP Installation per tank $50 _ Fire Suppression $30 Fuel Tank installation $50 System Acceptance (Per Tank) $50 Exhaust Hood/Duct �/ ❑ Natural Gas Installation $50 � Re inspection DBL (Per System) (other than annual) 0 Spray Booth $50 0 Inspection scheduled DBL and cancelled Tess than 24 hours Construction Insp. N/C e _ Emergency Vehicle A 21 4 FALSE ALARM PLANS TOTAL tij INSPECTION TOT PERMIT TOTAL TO50 TALI I ■ GRAND TOTAL IIIIII Main Comments: Date: e 2* o InspActor: -`. / -° /t_e...l. 46, • T itrus. csce 5 Count. Sheet Metal Inc. 5 314 South Flora Avow* ayeraesl. . 344S0 SOO762.7368 Correct Range Hood Exhaust Duct Installation to Meet Code Requirements Per Fire Marshal Inspection At Fung Garden Chinese Restaurant 5118 Gall Blvd. Zephyrhills, FL Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the SUBMITTED PLAN(S HA BEEN REYIE contractor's sole responsibility to ensure that the plans are in BY ZEPHYRHILL -, • HALS complete compliance with all applicable NFPA codes and � Date: / , CE local ordinances. In the event that further examination or ?itviewar: site inspection reveals areas of non- compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA Codes and local ordinances. b9flifTIOVe '..";r !O aehsig yitiat4r 9 tEtfirt :d Q ;"4.; :"- lafKagc .3(4e °teals: CCSM Office From: "Kerry Banter <kbamett@fire.zephyrhills.fl.us> To: "CCSM Office" <ccsm @tampabay.rr.c:om> Sent: Wednesday, June 02, 2010 2:51 PM Subject RE: Fung Garden Chinese Restaurant Steve, Thanks for getting with me. You would be correct for the most part. I believe everything should be scheduled to keep her from being down long. The fire barrier /enclosure that surrounds the duct needs to be taken out. Then everything should be cleaned by the hood cleaner. Any tiles that need to be replaced also should be done. I want to make sure we get rid of the grease build up in, around and behind the duct in the ceiling area. Once that is complete the pan can be installed on the curb to route the grease in the right direction. The duct then can be wrapped versus a new barrier being installed. As for the fan unit, some new hinges and a proper grease cup shall be installed. Please be advised a permit will be required to complete this work. Submit a plan showing scope of work. If you have any questions, please let me know. Kerry Barnett Fire Marshal 6907 Dairy Rd Zephyrhills, FL. 33545 (813) 780-0041 CELL: (813) 813-714-6326 This permit application is to accomplish the following: • Wrap exhaust duct with zero clearance fire wrap (specs attached). • Furnish and install a 16 ga. top pan to be welded to duct with continuous liquid tight weld and seal roof curb to duct to route accumulated grease back down to the hood. • Repair misaligned hinges on exhaust blower. • Clean and repair grease catch pan on blower. Also, to be accomplished by others: • Clean all grease from exhaust duct inside and outside. • Clean grease accumulation from surrounding area including top of hood, wall and roof trusses. • Remove and replace ceiling where grease contamination has occurred. Rig) 1nerrrial ' " s 1- Commercial Kitchen Grease Duct Fim Air Ventilation Duct Fire Protection Systems 1•9A'F; is %q . Product Data and Installation Guide ` ? ' 4 p0, IMC ;. # ti ilk r NFPA 96 o ' e0 NA10 * 4- 11131t VW) M � a ra"� Y I t ♦, li , 1. Product Description a Physical Characteristics Thermal Ceramics FireMaster' FastWrap+ is a one -layer foil- FireMsster Units encapsulated, non - combustible high temperature, low biopersis- Product Unit Size Ctn. Wt./Ctn. tence, flexible fireproofing wrap specifically tested to provide a 1 or , FastWrap+ Roll 2' x 24* x 20' 1 53 lbs. 2 hour fire rated enclosure for horizontal and vertical commercial (51 mm x 610mm x 6m) (24 kg) kitchen grease and air ventilation ducts. The core blanket chemistry FastWrap+ Roll 2" x 48" x 20' 1 100 lbs. is alkaline -earth silicate wool free of binders and lubricants. Thermal • (51 mm x 1.2m x 6m) (45 kg) Ceramics FireMaster FastWrap+ is classified by Omega Point FastWrap+ Collar Roll 1W x 6' x 20' 4 46 lbs. Laboratories Listing and Follow -up Service Program to ensure uni- (38.1 mm x 152mm x 6m) (20.9 kq) form thickness and density specifications, thus providing consis- Color White blanket with tency in end physical properties for required fire ratings. Thermal silver foil- encapsulation Ceramics FireMaster FastWrap+ is a proven performance altema- five through extensive testing to 1 or 2 -hour fire - resistance rated 4. SpeC1fications shaft enclosures. With its excellent insulating capability of with- This specification guide covers the application of Thermal Ceramics standing fire condition temperatures up to 2000 °F (1093°C), it pro- FireMaster FastWrap+ and Fire Barrier 2000 +, 1000 N/S or 1003 S/L tects combustible constructions at zero clearance at the overlap or Silicone Sealant. collar for commercial kitchen grease ducts in tight congested areas. Firm Thy_ When the duct penetrates fire rated walls and floors, Fire Barrier Resistive Enclosure Penetration 2000 +, 1000 N/S or 1003 S/L Silicone Sealant used in combination application Rating Specification System System with Thermal Ceramics FireMaster FastWrap+ provides an alternate Grease DuctS 1 or 2 1 layer GD513F, OPL means of protection to rigid shafts by maintaining the integrity of hours FastWrap+, 3' GD514F FS548F the 1 or 2 hour fire rated wall and floor assembly. (75mm) perimeter and longitudinal Product Features overlap • One -layer system with 3 optional installation techniques Air Ducts 1 or 2 ' 1 layer VAD516F OPL • Low biopersistent insulation blanket hours FastWrap+, 3` FS549F • Shaft alternative (75mm) perimeter • Zero clearance to combustibles protection at the overlap or and longitudinal collar overlap • Lightweight, compact design saves space • Lightweight flexible system requires minimum labor and resists cracking • Problem solver for tight, congested areas • Passive fire proof material does not lose fire fighting capabilities with age • Totally foil - encapsulated system protects against material degradation, potential fire hazards and allows easy installation. ,' • Product markings on foil ensure proper material identification for ; / easy inspections / • Wide variety through - penetration systems 7 ( , 2. v Detail A Applications , \ 1 or 2 Hour Commercial Kitchen Grease Duct Enclosure ',..;:\ 1 or 2 Hour Air Ventilation Duct Enclosure ��a