Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
09-9292
CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780 -0020 9292 FIRE ALARM SYSTEM PERMIT Z Z r4; IS+." s E' g :"','"'"!f; fir` ` r if : Permit Number: 9292 Address: 6907 DAIRY RD Permit Type: FIRE ALARM SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 02-26-21-0010-01000-0000 Improv. Cost: 12,000.00 �.:, 7 ° . - 77 * _ . Date Issued: 6/25/2009 Name: CITY OF ZEPHYRHILLS Total Fees: 305.00 Address: 6907 DAIRY RD Amount Paid: 305.00 ZEPHYRHILLS, FL. 33542 Date Paid: 6/25/2009 Phone: Work Desc: INSTALLATION OF FIRE ALARM- FEE WAIVED CITY PROPERTY SIMPLEX GRINNELL LP FIRE ALARM N � i �� 5 0.00 FIRE INSPECTION FEES 155.00 FIRE PLAN REVIEW FEES 100.00 .-:. cd , f I >Y FIRE ACCEPTANCE E '' . � � ' 10 � Ea . €'. s t: ," , CE Final . = . FIRE ELEVATOR RECALL Chapter 633, Florida Statutes, authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees, and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of $100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CO = 1 T WITH YOUR LENDER OR AN ATTORNEY BEFORE RE m • 2 ?sIG Y. - OTICE OF COMMENCEMENT." Wil .., /0/ 1----- - al CONTRACTOR SIGNATURE - !�j I • IC R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT - Fire Marshal Office - 813 - 780 -0041 q��v Fax- 813 -780 -0021 City of,ZephyrhillsFire s1 7saoazo p e �i{ gpplication Phone Contact for Permit 7 Z7 - 4 AI XIM D Receroed ,; no � w A te- - .� e ND Q `e. A / / 5 Owners Phone Number 1 I l Owner's Name Owner's Address i � 7 � , l s ft., It-d _ Z e A ' �� � �^ Titleholder Phone Number re Simple Titleholder Name Fee Slmp � � - SmpteTrttehoe Add .,.._ ,x • .....' . ,. ._ ■_. ., .e .•'.....::' •. . . .��"°: ta..... z ,...x...., _ ..... M`. �' 'A' 2 �u .si ": "i+l lu .f'v: ;-cd i � *�.w.Yr.��,.r .�.,.., ..,:. km 4/ //s. �L Lot r Job Address Parcel # Sub Division Waste Storage- ANNUAL = g uµ,•,ca,. Fumt atloTent l I Bio-HaLard Hazardous Material (Tier II or RQ Facility) ANNUAL Comm Exhaust Kitchen Hood/Duct (— Hood Installation - Controlled Burn 1-- LP /Natural Gas - Installation Emergency Generator < 30 kw = LP /Natural Gas - ANNUAL Safe i j Emergency on Mai ten nc kw = Places of Assembly- ANNUAL • L j Fire Protection Maintenance = A' L. tr y] ner 0 0 0 E Recreational Bum Sprinkler [asu e 0 0 C Sparklers 0 0 C Sprinkler System Installatio Hood Cleaning rinkler Sys Hood Suppression 0 0 Standpipes (Sp 1 Torch Roofing/Tar Kettle Fire Alarm Installation • Waste Tire Storage ANNUAL Fire Pumps u I 1 Fire Works Z o ® — Valuation of Project I I Flammable Application - ANNUAL 1I Fuel Tanks I Other: f Company [Ql G Contractor ��,��� Registered Y / 7v Fee Current Signature Xliii ,h � i7��Z j L f 70 / O74IC- f -�41,1- Atiii / 7 j D/i, -L- License # 1 Address / Company ELECTRICIAN I Registered Y / N Fee Current Y/ N Sicnature JI License # Address Company PLUMBER Registered Y/ N 1 Fee Current 1 Y/ N Signature License Address 1 1 Company ME CHANIC ALI Registered Y / N 1 Fee Current L Y/ N Signature 11 Address I •License# 1 Company OTHER Company Y / N Fee Current Y/ N Signature Address y f License Directions: a,_ w Fill out application completely. Owner & Contractor sign back of application, notarized (Or, copy of signed contract with owner) If over $2500, a Notice of Commencement is required.(Mechanical work over $5000) Supply two (2) sets of drawings with applicable documentation Parcel # - obtained from Property Tax Notice (http: /lappraiser.pascogov.com) Allow 10 -14 days for review after submittal date. 'NOTICE∎;OF:DEED RESTRICTIONS: The undersigned understands that this permit maybe'subjectto "deed "msh lctions" which may be more restrictive than County regulations. The•.undersigned.assumes responsibility .forrcomplianae'with any .applicable deed restrictions. UNLICENSED 'CONTRACTORS AND 'CONTRACTOR RESP.ONSIBILmES: If 'the owner has - hired - :a- contractor or - - contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited - Fora misdemeanor violation under state law. If the owner or intended contractor are uncertain .as to what licensing requirements may :apply for the intendedlwork, they are advised to contact the Pasco County Building Inspection Division — Licensing Section_at 727-847 - 8009. Furthermore, if the 'owner has hired .a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which will be responsible. if you, as owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled permitting .privileges in Pasco County. CONSTRUCTION .LIEN LAW (Chapter713, Florida Statutes, -as :amended): If valuation of work is $2500.00 or more, I certify that 1, - the applicant, have .been provided with a copy of the 'Florida Construction Lien Law — Homeowner's Protection Guide" prepared by Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver itto the "owner" prior to commencement. CONTRACTOR'S /OWNER'S •AFFIDAVIT: I certif=y that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other . government agencies may apply to the intended work, and that it is my responsibility to identify what actions 1 must take to be in compliance. . If I am the AGENTFORTHE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. -1 understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit is-sued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the perrnit is suspended or abandoned for a period of six (6) months after the time.the work da s and demonstrate An may be requested, in writing, from the Building Official. for a period not to exceed ninety (90) y justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A'NOTICE 'OF 'COMMENCEMENT MAY 'RESULT IN 'YOUR - PAYING TWICE FOR IMPROVEMENTS ` YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WiTH YOUR LENDER O N ATTOR = ' BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDAJURAT (F.S.11 .0 Q om. OWNER OR /fre CONTRACTOR Subscribed and swom (r affirmed).before me this Subscribed and swom to (or affirmed) before me this by by y Who is/are personally known to me or has/have produced Who is/are personally known to me i has/have pon. roduced as identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed, printed ranted or stamped Name of Notary typed, printed or stamped - • SimplexGrinnell SimplexGrinnell LP 4701 Oak Fair Blvd Tampa, Florida 33610 Tele: 813- 626 -5482 Fax: 813- 886 -6320 www.simplexgrinnell.com AUTHORIZATION I, Ronald W. Reiss, hereby authorize the following to sign for and acquire permits and licenses using my State of Florida License No. 90251200012007. Monica Watson Craig Watson Jessica Watson Sonia M. Lee Patricia J. Arizmendi Kirk Blackburn If you should have any questions, please feel free to contact me at 813- 626 -5482. Ron d Reiss License No. 90251200012007 STATE OF: FLORIDA COUNTY OF: HILLSBOROUGH . Date: --J' // Du! Notary Public: �.� ' „uu,,, JULIE KENYON ``�ti r n � °p , { tY A,,Qi, , ' Notary Public - State of Florida �z c My Commission Expire,' Nov 27, 2010 ` v" ;` t�2 �� Commission # OD 617830 �', , ��:`` Ronde c:Thin! ighN„Lonai!! :a'.Assn Fire, Security, Communications, Workforce Solutions, Sales & Service Offices & Representatives in Principal Cities throughout the World Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (813) 780 -0041 Kerry Barnett Fax (813) 780 -0044 E- mail: kbarnett@fire.zephyrhills.fl.us Plan Review #: 09 -052 Project: Sprinkler System Number of Pages: 1 plus details and calcs June 24, 2009 I have received and reviewed the plans for the fire sprinkler system located at 6907 Dairy Road and will allow this to move forward. Obtaining permit, the applicant acknowledges complying with the items listed below. All permit and inspection fees have been waived due to departmental (City) project. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. 1. Plans were reviewed utilizing NFPA 13, latest edition. 2. A 5" Storz shall be installed for the FDC versus the standard 4" by 2' h " x2Y2 ". 3. Underground, prior to cover up, connection and pressure test shall be conducted. 4. Tamper switches shall be installed on double backflow preventor. Inspections Required: 1. Underground Pressure Test 2. Pressure Test 3. Acceptance Test KERRY .711f TT, FIRE MARSHAL ***Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a fmal approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Fire Chief Keith Williams Bus (813)780 -0041 Fax (813)780 -0044 FIRE SERVICE USER FEES Occupancy No.: // / Plan No.: S — 0 Contractor: / . / &.-z >, /` Business Name: �' / Billing Address: _� i` 3 ,r' /i Business Address: ' �� .I /4/7--- P Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: _ PLAN REVIEW FEES _ INSPECTION FEES PERMIT FE _ FALSE ALARM FEE Amik _ Site Plan N/C J Annual N/C 0 Sprinkler '� — 1st Alarm N/C _ Multi -Family /Commercial .06 sf _ 1st Re- inspection N/C Standpipes • ,-- 2nd Alarm N/C (Minimum Charge $25.00 _ 2nd Re- inspection $100 II Fire Pump $50 — 3rd Alarm N/C El Plan Revisions DBL _ 3rd Re- inspection $250 II Hoods $50 — 4th Alarm $100 4th Re- Inspection $500 , Fire Alarm $50 _ 5th Alarm $150 — SPRINKLER SYSTEMS (Business closed until , LP Gas $50 _ 6th Alarm 5200 0 - 25 Heads $ violations corrected) ,Natural Gas $50 _ NON COMPLIANCE $150 26 plus Heads 100 SPRINKLER SYSTEM ,Fuel Tanks- per tank $50 Ali , Sparklers STANDPIPE SYS ��: ydro Undergrounds $100 Per Riser $50 `j Hydrostatic Test c"_•r "� , Fire Works $500 FIRE PUMP `fit Acceptance Test s rsystem ;system , Camp Fire $25 fl Per Pump $100 , ydrant Flow I Controlled Bum $100 _ FIRE ALARM SYSTEM , Hood/Duct $50 — 0 - 25 Devices $50 _ FIRE ALARM SYSTEM ■ Place of Assembly $50 Annual _ 26 plus Devices $100 _ System Acceptance $50 II Fire Protection $25 (JPPRESSION SYSTEMS /� — Recall Acceptance $50 III Flammable Application $50 Annual Wet ,� :ti _ OTHER , Waste Tire Storage $50 Annual r Dry 1 _ Fire Wall/Smoke Wall $15 per wan , Generator < KW $100 _ CO2 $50 _ LP Gas $25 per tank 111 Generator >30 KW 150 — Other $50 — Natural Gas $25 persystem ■ Bio-Hazard Waste $100 Annual KITCHEN EXHAUST _ I Fumigation Tenting $50 Ei Hood/Ducts $50 _ Tent 10k10' or greater $15 per tent , Torch Pot/Applied $50 OTHER _ Pump $45 , Haz. Materials 5100 Annual _ LP Installation per tank $50 — Fire Suppression $30 Fuel Tank Installation $50 _ System Acceptance (Per Tank) $50 _ Exhaust Hood/Duct $30 0 Natural Gas Installation $50 _ Re inspection DBL (Per System) (other than annual) _ ID Spray Booth $50 El Inspection scheduled DBL and cancelled less than _ _ 24 hours _ Construction lnsp. N/C _ Emergency Vehicle Ac. $50 l / ' FALSE ALARM PLANS TOTAL urn INSPECTION TOTAL _(r PERMIT TOTAL TOTAL /.0 GRAND TOTAL l `-3 - f Comments: Date: /2V ate: /2 "9 / Inspgctor: "f4 I/ W -- f�. ■ tL,CD / Fire & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series TY -FRB — 2.8, 4.2, 5.6, and 8.0 K- factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General tained when exposed to corrosive at- mospheres. Although corrosion resis- � � Description taut coated sprinklers have passed the standard corrosion tests of the appli- 4„F cable approval agencies, the testing is The Series TY -FRB, 2.8, 4.2, 5.6, and not representative of all possible cor- Wig 8.0 K- factor, Upright and Pendent rosive atmospheres. Consequently, it Sprinklers described in this data sheet is recommended that the end user be are quick response - standard cover- consulted with respect to the suitability - " age, decorative 3 mm glass bulb type 9 9 YP of these coatings for any given corro- spray sprinklers designed for use in sive environment. The effects of ambi- light or ordinary hazard, commercial ent temperature, concentration of occupancies such as banks, hotels, chemicals, and gas /chemical velocity, �" shopping malls, etc. should be considered, as a minimum, The recessed version of the Series along with the corrosive nature of the TY -FRB Pendent Sprinkler, where ap- chemical to which the sprinklers will be plicable, is intended for use in areas exposed. with a finished ceiling. It uses either a An intermediate level versions of the Style 10 (1/2 inch NPT) or Series TY -FRB Pendent Sprinklers or j rr Style 40 (3/4 inch NPT) Recessed Es- are detailed in Technical Data Sheet r cutcheon with 1/2 inch (12,7 mm) of TFP356, and Sprinkler Guards are de- recessed adjustment or up to 3/4 inch tailed in Technical Data Sheet TFP780 (19,1 mm) of total adjustment from the �Ir flush pendent position, or a two -piece WARNINGS Style 20 (1/2 inch NPT) or Style 30 (3/4 The Series TY -FRB Sprinklers de- inch NPT) Recessed Escutcheon with scribed herein must be installed and 1/4 inch (6,4 mm) of recessed adjust- maintained in compliance with this ment or up to 1/2 inch (12,7 mm) of document, as well as with the applica- total adjustment from the flush pen ble standards of the National Fire Pro - dent position. The adjustment pro- tection Association, in addition to the /� vided by the Recessed Escutcheon re- standards of any other authorities hay- Model /Sprinkler duces the accuracy to which the fixed ing jurisdiction. Failure to do so may pipe drops to the sprinklers must be impair the performance of these de- Identification cut. vices. Corrosion resistant coatings, where The owner is responsible for maintain- Numbers applicable, are utilized to extend the ing their fire protection system and de- life of copper alloy sprinklers beyond vices in proper operating condition. TY1131 - Upright 2.8K, 1/2 "NPT ' that which would otherwise be ob- The installing contractor or sprinkler TY1231 - Pendent 2.8K, 1/2 "NPT manufacturer should be contacted TY2131 - Upright 4.2K, 1/2 "NPT with any questions. TY2231 - Pendent 4.2K, 1/2"NPT IMPORTANT TY3131 - Upright 5.6K, 1/2 "NPT Always refer to Technical Data TY3231 - Pendent 5.6K, 1/2 "NPT Sheet TFP700 for the "INSTALLER TY4131 - - Upright 8.0K, 314 "NPT WARNING" that provides cautions TY4231 - Pendent 8.0K, 3/4 "NPT with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 APRIL, 2006 TFP171 Page 2 of 10 TFP171 ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING 1/2 ** NOMINAL RECESSED SURFACE NPT MAKE -IN ESCUTCHEON SSU* DEFLECTOR 1 , ! P 5 2 -1/4" 1.1.-- lo1' I 7/16" (57,2 mm) 1 = ��� NOMINAL i 4 MAKE -IN 2 1- 9/16" I rl 2- 3/16" .10 3 (39,7 mm) 1110 I, WRENCH i ■ II FLATS _ (55,6 mm) 0; ; � = 1 7 SSP DEFLECTOR * - 2 -7/8" (73,0 mm) DIA. 1/2" NPT ** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw * * Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING 1/2 ** NOMINAL RECESSED SURFACE NPT MAKE -IN ESCUTCHEON SSU i DEFLECTOR 1 \ ,..-- j — �— 6* 07)7\k 2- 3/16" mi� } '■rrm 7/16" i ce ' 5 ��� (11,1 mm) I I a � NOMINAL 4 (55,6 mm) L MAKE -IN 1,1/2" 1 mm I lg. fi Y A , I 2- 3/16 '� (38 2 WRE NCH + ` i (55,6 mm) 0 y o 1 FLATS = 3 i I 1 SSP DEFLECTOR 2 -7/8" (73,0 mm) DIA. 1 1/2" NPT ** f PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw * * Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K- FACTOR, 1/2 INCH NPT TFP171 Page 3 of 10 ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING 1/2„ ** NOMINAL RECESSED SSU* SURFACE NPT MAKE -IN ESCUTCHEON DEFLECTOR 6 11111 r T 2 -3/16" } 'sf 7/16" 5 ( 11,1 mm) (55,6mm) t I -I �iT �— NOMINAL �1� MAKE -IN (38,1 /mm) I' I " Q� �D 2 FLATS H — + (55,6 2-3/16 mm) 3 SSP DEFLECTOR* , 2 -7/8" (73,0 mm) DIA. 1 1/2" NPT ** } 1 PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw * * Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES 7Y-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) STYLE 30 or 40 PLATE SEATING 3/4 ** NOMINAL RECESSED SSU* SURFACE NPT MAKE -IN ESCUTCHEON DEFLECTOR 1 c ry - r - - - -�-�y r"7T0.., `I I^. E ' 5 6 1/2" 2- 5/16" 1 �� � � (12,7 mm) (58,7 mm) � A `_ — I NOMINAL L 4 �1� MAKE -IN ma 1 -9/16" 4 1 WRE NCH g� 2 -1/4" y � "d 2 (39,7 mm) i 1 j = i II — (57,2 mm) 400 T k -- 111 FLATS i 3 SSP DEFLECTOR --- 2 -7/8" (73,0 mm) DIA. j 3/4NPT** t " PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw * * Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K- FACTOR, 3/4 INCH NPT Page 4 of 10 TFP171 SPRINKLER FINISH (See Note 7) Technical K TYPE TEMP. BULB NATURAL CHROME WHITE*** LIQUID BRASS PLATED POLYESTER Data 135 °F /57 °C Orange Approvals PENDENT 155 °F /68 °C Red UL and C -UL Listed. (TY1231) 1, 2, 3, 5 FM, LPCB, and NYC Approved. and 175F/79°C Yellow (Refer to Table A and B for complete .. UPRIGHT 200 °F /93 °C Green approval information including corro- 2.8 (TY1131) 286 °F /141 °C Blue sion resistant status.) 1/2" Maximum Working Pressure NPT 135 °F /57 °C Orange Refer to Table C. RECESSED 155"F/68°C Red Discharge Coefficient PENDENT 175"F/79°C Yellow K = 2.8 GPM /psi / (40,3 LPM /bar / K = 4.2 GPM /psi / (60,5 LPM /bar Figure 5 200 °F /93 °C Green 1, 2, 5 K = 5.6 GPM /psil / (80,6 LPM/bar 135 °F /57 °C Orange K = 8.0 GPM /psil / (115,2 LPM /bar RECESSED 155 °F /68 °C Red Temperature Ratings PENDENT Refer to Table A and B (TY1231)** 175° F /79 °C Yellow Finishes Figure 6 200 °F /93 °C Green Sprinkler: Refer to Table A and B. 135 °F /57 °C Orange Recessed Escutcheon: White Coated, PENDENT Chrome Plated, or Brass Plated. (TY2231) 155 °F /68 °C Red and 175 °F /79 °C Yellow Physical Characteristics UPRIGHT 200 °F /93 °C Green Frame Bronze (TY2131) Button Brass /Copper 4.2 286 °F /141 °C Blue 1 2 Sealing Assembly 1/2" NPT 135 °F /57 °C Orange Beryllium Nickel w /Teflont Bulb Glass RECESSED 155 °F /68 °C Red Compression Screw Bronze PENDENT (TY2231)* 175 °F /79 °C Yellow Deflector Copper /Bronze Bushing (K =2.8) Bronze Figure 7 200 °F /93 °C Green 135 °F /57 °C Orange Operation RECESSED 155 °F /68 °C Red PENDENT The glass Bulb contains a fluid which (TY2231) ** 175 °F /79 °C Yellow expands when exposed to heat. When Figure 8 200 °F /93 °C Green the rated temperature is reached, the fluid expands sufficiently to shatter the NOTES: glass Bulb, allowing the sprinkler to 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. activate and water to flow. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) as Quick Re- sponse Sprinklers. Design 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. Criteria 5. Approved by the City of New York under MEA 354 -01 -E. 7. Where Polyester Coated Sprinklers are noted to be UL and C -UL Listed, the sprin- The Series TY - FRB Pendent and U klers are UL and C -UL Listed as Corrosion Resistant Sprinklers. p * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment right Sprinklers are intended for fire Recessed Escutcheon, as applicable. protection systems designed in ac- ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment cordance with the standard installation Recessed Escutcheon, as applicable. rules recognized by the applicable * ** Frame and Deflector only. Listings and approvals apply to color (Special Order). Listing or Approval agency (e.g., UL N /A: Not Available Listing is based on the requirements of , TABLEA NFPA 13, and FM Approval is based LABORATORY LISTINGS AND APPROVALS on the requirements bf FM's Loss Pr 2.8 AND 4.2 K- FACTOR SPRINKLERS vention Data Sheets ). Only the Style m 10, 20, 30, or 40 Recessed Escutch- F- eon, as applicable, is to be used for a recessed pendent installations. a) N o) d E' O a 7 0 4- TFP171 Page 5 of 10 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL CHROME WHITE*** LEAD LIQUID BRASS PLATED POLYESTER COATED 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY3231) 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5 and 175 °F /79 °C Yellow UPRIGHT 200 °F /93 °C Green 5.6 (TY3131) 286F/141°C Blue 1/2" NPT 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 4, 5 N/A (TY3231)* 175 °F /79 °C Yellow Figure 9 200 °F /93 °C Green 135 °F /57 °C Orange RECESSED 155F/68°C Red PENDENT 1, 2, 3, 4, 5 1, 2, 4, 5 N/A (TY3231) ** 175 °F /79 °C Yellow Figure 10 200 °F /93 °C Green 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY4231) 1, 2, 5 and 175 °F /79 °C Yellow 1, 2, 3, 4, 5, 6, 7 UPRIGHT 200 °F /93 °C Green 8.0 (TY4131) 286 °F /141 °C Blue 3/4" NPT 135 °F /57 °C Green RECESSED 155 °F /68 °C Orange PENDENT 1, 2, 4, 5 N/A (TY4231)* 175F/79°C Red Figure 11 200F/93°C Yellow 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 3, 4, 5 N/A (TY4231) ** 175 °F /79 °C Yellow Figure 12 200 °F /93 °C Green NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31 -53- 428- 4444/Fax 31 -53- 428 - 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. * ** Frame and Deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available • TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K- FACTOR SPRINKLERS Page 6 of 10 TFP171 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED POLYESTER COATED PENDENT (TY3231) and 2 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/2" RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A 3/4" RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (TY3131) OR 1/2" RECESSED PENDENT 175 PSI (12,1 BAR) NPT (TY323) (SEE NOTE 1) N/A PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8 UPRIGHT (TY4131) 3/4" RECESSED PENDENT NPT (TY4231) N/A NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C -UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE nections. Higher levels of torque may The Series TY -FRB Recessed Pen - Installation distort the sprinkler inlet and cause dent Sprinklers must be installed in leakage or impairment of the sprinkler. accordance with the following instruc- The Series TY -FRB Sprinklers must tions. be installed in accordance with the fol- Do not attempt to make -up for insuffi- lowing instructions: cient adjustment in the escutcheon Step A. After installing the Style 10. plate by under- or over - tightening the 20, 30, or 40 Mounting Plate, as appli- NOTES sprinkler. Readjust the position of the cable, over the sprinkler threads and Do not install any bulb type sprinkler if sprinkler fitting to suit. with pipe thread sealant applied to the pipe threads hand li hten quid from the bulb. With the sprinkler The Series TY -FRB Pendent and Up- klerr i nto the sprinkler lfitting. the sprin q P right Sprinklers must be installed in held horizontally, a small air bubble accordance with the following instruc- Step B. Tighten the sprinkler into the should be present. The diameter of the tions. sprinkler fitting using only the W -Type air bubble is approximately 1/16 inch 7 Recessed Sprinkler Wrench (Ref. for the 135F/57°C to 3/32 Step 1. Pendent sprinklers are to be ( 1,6 mm) 286°F/141°C installed in the pendent position, and Figure 14). the W-Type to Figure inch (2,4 mm) for the 286 °F /141 C p p 2, 3, and 4, the W -Type 7 Recessed temperature ratings. upright sprinklers are to be installed in Sprinkler Wrench is to be applied to the upright position. the sprinkler wrench flats. A leak tight 1/2 inch NPTsprinklerjoint Step 2. W ith pipe thread sealant a p should be obtained with a torque of 7 p p i p p Step C. After the ceiling has been in- to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- plied to the pipe threads, hand tighten stalled or the finish coat has been ap- mum of21 ft. lbs. (28,5 Nm) of torque the sprinkler into the sprinkler fitting. plied, slide on the Style 10, 20, 30, or may be used to install sprinklers with Step 3. Tighten the sprinkler into the 40 Closure over the Series TY -FRB 1/2 NPT connections. A leak tight 3/4 sprinkler fitting using only the W -Type Sprinkler and push the Closure over inch NPT sprinkler joint should be ob- 6 Sprinkler Wrench (Ref. Figure 13). the Mounting Plate until its flange tained with a torque of 10 to 20 ft.lbs. With reference to Figures 1, 2, 3, and comes in contact with the ceiling. (13,4 to 26,8 Nm). A maximum of 30 4, the W -Type 6 Sprinkler Wrench is to ft .lbs.(40,7Nm)oftorqueistobeused be applied to the sprinkler wrench to install sprinklers with 3/4 NPT con- flats. TFP171 Page 7 of 10 2 -7/8" DIA. 2 -7/8" DIA. (73,0 mm) 3/4" (19,1 mm) (73,0 mm) 5/8±1/4" 1/211/8" 1/2" (12,7 mm) (15,916,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (12,713,2 mm) 2 -1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) 1 MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER I PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" 1; (3,2 mm) 1 m (3,2 mm) 111 I- ii j MOUNTING t MOUNTING �: 1 SURFACE �' SURFACE iii ���� ii •�ks, CLOSURE SERIES 1- 5/16" (33,3 mm) CLOSURE SERIES 1 -5/16" (33,3 mm) TY -FRB 13/16" (20,6 mm) TY-FRB 1 -1/16" (27,0 mm) FIGURE 5 FIGURE 6 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K- FACTOR, 1/2 INCH NPT 2.8 K- FACTOR, 1/2 INCH NPT 2 -7/8" DIA. 2 -7/8" DIA. 5/811/4" (73,0 mm) 314" (19,1 mm) (73,0 mm) 1/211/8" 1/2" (12,7 mm) (15,916,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (12,713,2 mm) 2 -1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) 1 MOUNTING FACE OF (57,2 mm) I MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" •!' (3,2 mm) •� (3,2 mm) Jill a , lalil, , ��l�ll, ��' mil r , 111 w MOUNTING IN �r MOUNTING SURFACE � ■ SURFACE -• -- .- .. CLOSURE SERIES 1 -1/4" (31,8 mm) , CLOSURE SERIES 1 -1/4" (31,8 mm) TY-FRB 3/4" (19,1 mm) TY-FRB 1" (25,4 mm) FIGURE 7 FIGURE 8 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K- FACTOR, 1/2 INCH NPT 4.2 K- FACTOR, 1/2 INCH NPT Care and objects; otherwise, non - operation in by brushing it with a soft bristle brush. the eventofa fire or inadvertent opera- Care must be exercised to avoid dam M aintenance tion may result age to the sprinklers - before, during, Absence of an escutcheon, which is and after installation. Sprinklers dam - The Series TY -FRB Sprinklers must used to cover a clearance hole, may aged by dropping, striking, wrench be maintained and serviced in accord delay the time to sprinkler operation in twist/slippage, or the like, must be re- ance with the following instructions: a fire situation. placed. Also, replace any sprinkler Sprinklers that are found to be leaking that has a cracked bulb or that has lost NOTES or exhibiting visible signs of corrosion liquid from its bulb. (Ref. Installation • Before closing a fire protection system must be replaced. Section). . main control valve for maintenance never must i ne r tic sprinklers rnklers mus be Frequent visual inspections are rec- work on the fire protection system that Automatic plated, coated s ne err ommended to be initially performed for it controls, permission to shutdown the p p otherwise corrosion resistant coated sprinklers, affected fire protection system must be altered after leaving the factory. Modi- after the installation has been com- obtained from the proper authorities fied sprinklers must be replaced. pleted, to verify the integrity of the cor- and all personnel who maybe affected Sprinklers that have been exposed to rosion resistant coating. Thereafter, by this action must be notified. corrosive products of combustion, but annual inspections per NFPA 25 have not operated, should be replaced should suffice; however, instead of in- The owner must assure that the sprin- if they cannot be completely cleaned specting from the floor level, a random klers are not used for hanging of any by wiping the sprinkler with a cloth or Page 8 of 10 TFP171 2 -7/8" DIA. _ 2 -7/8" DIA. 5/8±1/4" (73,0 mm) (73,0 mm ) 3/4" (19,1 mm) 1/2±1/8" 1/2" (12,7 mm) (15,9±6,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (12,7±3,2 mm) 1 2 -1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8 �� (3,2 mm) l� (3,2 / = / A m X 11 I or IIP � MOUNTING MOUNTING , SURFACE SURFACE - ,_. CLOSURE SERIES 1 -1/4" (31,8 mm) CLOSURE SERIES 1 -1/4" (31,8 mm) TY-FRB 3/4" (19,1 mm) TY-FRB 1" (25,4 mm) FIGURE 9 FIGURE 10 SERIES TY -FRB RECESSED PENDENT SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K- FACTOR, 1/2 INCH NPT 5.6 K- FACTOR, 1/2 INCH NPT 2 -7/8" DIA. - 2 -7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) 1/2 ±1/8" (73,0 mm) 1/2" (12,7 mm) (15,9±6,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (12,7±3,2 mm) 2 -1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) (57,2 mm ) MOUNTING FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" r M ,A, (3,2 mm) ■�� % /i ' (3,2 mm) i %A. it 11 —i 1 f MOUNTING 4 MOUNTING � 1 SURFACE SURFACE i II , CLOSURE SERIES 1 -5/16" (33,3 mm) CLOSURE SERIES 1 -5/16" (33,3 mm) TY-FRB 13/16" (20,6 mm) TY-FRB 1 -1/16" (27,0 mm) FIGURE 11 FIGURE 12 SERIES TY -FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K- FACTOR, 3/4 INCH NPT 8.0 K- FACTOR, 3/4 INCH NPT sampling of close -up visual inspec- WRENCH tions should be made, so as to better RECESS determine the exact sprinkler condi- tion and the long term integrity of the WRENCH RECESS ri1 corrosion resistant coating, as it may (END "A" USED FOR be affected by the corrosive conditions 1/2" NPT MODELS) ^ present.. ■ II i i The owner is responsible for the in- ` u spection, testing, and maintenance of WRENCH RECESS ....... their fire protection system and de- PUSH WRENCH vices in compliance with this docu- (END "B" USED FOR P 3/4" NPT MODELS) IN TO ENSURE ment, as well as with the applicable ENGAGEMENT standards of the National Fire Protec- FIGURE 13 'WITH SPRINKLER tion Association (e.g., NFPA 25), in W -TYPE 6 SPRINKLER WRENCHING AREA addition to the standards of any other WRENCH FIGURE 14 authorities having jurisdiction. The in W -TYPE 7 RECESSED stalling contractor or sprinkler manu- SPRINKLER WRENCH facturer should be contacted relative tested, and maintained by a qualified to any questions. Inspection Service in accordance with It is recommended that automatic local requirements and /or national sprinkler systems be inspected, codes. TFP171 Page 9 of 10 P/N 57 - XXX - X - XXX I I TEMPERATURE MODEL/SIN RATING SPRINKLER 330 2.8K UPRIGHT (1/2 "NPT) TY1131 135 135 °F /57 °C 331 2.8K PENDENT (1/2 "NPT) TY1231 1 NATURAL BRASS 155 155F/68°C 340 4.2K UPRIGHT (1/2 "NPT) TY2131 4 WHITE POLYESTER 175 175 °F /79 °C 341 4.2K PENDENT (1/2 "NPT) TY2231 3 WHITE (RAL9010)* 200 200 °F /93 °C 370 5.6K UPRIGHT (1/2 "NPT) TY3131 9 CHROME PLATED 286 286 °F /141 °C 371 5.6K PENDENT (1/2 "NPT) TY3231 7 LEAD COATED 390 8.0K UPRIGHT (3/4 "NPT) TY4131 391 8.0K PENDENT (3/4 "NPT) TY4231 * Eastem Hemisphere sales only. TABLE D PART NUMBER SELECTION SERIES TY -FRB PENDENT AND UPRIGHT SPRINKLERS Limited charges, regardless of whether TFBP was informed about the possibility of Ordering such damages, and in no event shall Warranty TFBP's liability exceed an amount Procedure Products manufactured by Tyco Fire & equal to the sales price. Y y The foregoing When placing an order, indicate the Building Products (TFBP) are war- 9 n9 warrant y is made in lieu full product name. Refer to the Price ranted solely to the original Buyer for of any and all other warranties. ex List for complete listing of Part Num- ten (10) years against defects in mate- Dress or implied. including warranties bers. rial and workmanship when paid for of merchantability and fitness fora par - and properly installed and maintained ticularpurpose. Contact your local distributor for avail - under normal use and service. This This limited warranty sets forth the ex- ability. warranty will expire ten (10) years clusive remedy for claims based on Sprinkler Assemblies with NPT from date of shipment by TFBP. No failure of or defect in products, materi- Thread Connections: warranty is given for products or com- als or components, whether the claim Specify: (Specify Model /SIN), Quick ponents manufactured by companies is made in contract, tort, strict liability Response, (specify K- factor), (specify not affiliated by ownership with TFBP or any other legal theory. temperature rating), Series TY -FRB or for products and components which have been subject to misuse, improper This warranty will apply to the full ex- (specify Pendent or Upright) Sprinkler installation, corrosion, or which have tent permitted by law. The invalidity, in with (specify type of finish or coating), not been installed, maintained, modi- whole or part, of any portion of this P/N (specify from Table D). fied or repaired in accordance with ap- warranty will not affect the remainder. plicable Standards of the National Fire Recessed Escutcheon: Protection Association, and /or the Specify: Style (10, 20, 30, or 40) Re- standards of any other Authorities cessed Escutcheon with (specify") fin - Having Jurisdiction. Materials found ish, P/N (specify *). by TFBP to be defective shall be either • Refer to Technical Data Sheet TFP770. repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor Sprinkler Wrench: authorizes any person to assume for it, Specify: W -Type 6 Sprinkler Wrench, any other obligation in connection with P/N 56- 000 -6 -387. the sale of products or parts of prod- ucts. TFBP shall not be responsible for Specify: W -Type 7 Sprinkler Wrench, sprinkler system design errors or inac- P/N 56- 850 -4 -001. curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor Page 10 of 10 TFP171 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqco I Fire & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series DS -1 — 5.6 K- factor Dry Type Sprinklers Quick Response, Standard Coverage standards of any other authorities hay - General ing jurisdiction. Failure to do so may impair the performance of these de- Description vices. The Series DS -1, 5.6 K- factor, Quick The owner is responsible for maintain- ing their fire protection system and de- Response, Standard Coverage, Dry Type Sprinklers are decorative 3 mm vices in proper operating condition. glass bulb automatic sprinklers de The installing contractor or sprinkler signed for the following typical uses: manufacturer should be contacted with any questions. • where pendent sprinklers are re- quired on dry pipe systems that The Series DS -1 Dry Type Sprinklers are exposed to freezing tempera- must only be installed in fittings that tures (e.g. sprinkler drops from un meet the requirements of the Design heated portions of buildings) Criteria section. • where sprinklers and /or a portion of the connecting piping may be Model /Sprinkler 11 ., exposed to freezing temperatures Identification (e.g. sprinkler drops from wet sys- tems into freezers, sprinkler Numbers sprigs from wet systems into un- heated attics, or horizontal piping extensions through a wall to pro - TY3235 - (Pendent) '$ ¢✓C tect an unheated area of a build- TY3135 - (Upright) AC. ing) TY3335 - (Horizontal Sidewall) • where sprinklers are used on sys- : " tems that are seasonably drained Technical ,. to avoid freezing (e.g. vacation re- sort areas) Data WARNINGS Approvals The Series DS -1 Dry Type Sprinklers UL and C -UL Listed. Physical Characteristics described herein must be installed and FM and NYC Approved. Inlet Copper maintained in compliance with this (Refer to Table A) Plug Copper document, as well as with the applica- Yoke Stainless Steel ble standards of the National Fire Pro- Maximum Working Pressure Casing . . Galvanized Carbon Steel tection Association, in addition to the 175 psi (12,1 bar) Insert Bronze Inlet Thread Connection Bulb Seat Stainless Steel 1 inch NPT (Standard Order) Bulb Glass ISO 7 -R1 Compression Screw Bronze IMPORTANT Deflector Bronze Always refer to Technical Data Discharge Coefficient Frame Bronze Sheet TFP700 for the "INSTALLER K = 5.6 GPM /psi Guide Tube Stainless Steel WARNING" that provides cautions (80,6 LPM /barli Water Tube Stainless Steel with respect to handling and instal- Temperature Ratings Spring Stainless Steel lation of sprinkler systems and com Refer to Table A Sealing Assembly ponents. Improper handling and in- Beryllium Nickel wireflon* stallation can permanently damage Finishes Escutcheon Carbon Steel a sprinkler system or its compo- Sprinkler: Natural Brass, Chrome *Registered Trademark of DuPont nents and cause the sprinkler to fail Plated, White Polyester to operate in a fire situation or cause Escutcheon: White Coated or Chrome Patents it to operate prematurely. Plated U.S.A. Patent No. 5,188,185 Page 1 of 8 APRIL, 2004 TFP510 Page 2 of 8 TFP510 SPRINKLER FINISH TY3235 Pendent TY3235 Pendent TY3335 Hor. Sidewall w/ Standard w/ Std. Escutcheon with top of Recessed Escutcheon (Ref. Fig. 5) Deflector - to-Ceiling (Ref. Fig. 3) w/ Deep Escutcheon distance of w/ Wide Flange (Ref. Fig. 6) 4 to 12 inches Recessed Escutcheon w/o Escutcheon (100 to 300 mm) (Ref. Fig. 4) (Ref. Fig. 7) w/ Std. Escutcheon (Ref. Fig. 9) TY3135 Upright w/ Deep Escutcheon w/o Escutcheon (Ref. Fig. 10) (Ref. Fig. 8) w/o Escutcheon (Ref. Fig. 11) Temperature Bulb Natural Chrome White Natural Chrome White Natural Chrome White Rating Color Code Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135 °F /57 °C Orange 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1*, 2 *, 3 ", 4 1*, 2 *, 4 155 °F /68 °C Red 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1*, 2`, 3 ", 4 1*, 2 *, 4 175 °F /79 °C Yellow 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1*, 2 *, 3 4 1*, 2 *, 4 200 °F /93 °C Green 1 , 2, 3, 4 1 , 2, 4 1 , 2, 3, 4 1 , 2, 4 1*, 2 *, 3 ", 4 1 *, 2 *, 4 286 °F /141 °C Blue N/A 1, 2, 3, 4 1, 2, 4 1*, 2 *, 3 ", 4 1*, 2 *, 4 Notes: 1. Listed by Underwriters Laboratories, Inc (Maximum order length of 48 inches). 2. Listed by Underwriters Laboratories for use in Canada. (Maximum order length of 48 inches). 3. Approved by Factory Mutual Research Corporation (Maximum order length of 48 inches) 4. Approved by the City of New York under MEA 352 -01 -E. Light and Ordinary Hazard Occupancies Only. ** Light Hazard Occupancies Only. N/A - Not Available. TABLE A SERIES DS -1, QUICK RESPONSE - STANDARD COVERAGE, DRY TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS �i�. WRENCH PLUG WITHri INLET RECESS GASKETED SPRING PLATE SEAL 11171 I SPRING YOKE � 1� =z CASING 1 1 \.� WATER 1 PUSH WRENCH IN TO TUBE 1 i 1 INSERT SPRINKLER WRENCHING AREA 1 I > GUIDE - 11'V FIGURE 2 TUBE - - $ SEAT W -TYPE 7 SPRINKLER WRENCH FRAME t A k Ir i � � ,i /__ 3 mm ' P' 4 / BULB VENT HOLE 'I Il � .' COMPRESSION DEFLECTOR -` SCREW FIGURE 1 SERIES DS -1 QUICK RESPONSE DRY TYPE SPRINKLER ASSEMBLY TFP510 Page 3 of 8 SPRINKLER FITTING SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN (REFER TO DESIGN (REFER TO DESIGN CRITERIA SECTION) - , -- CRITERIA SECTION) ' - - 1 CRITERIA SECTION , - - I r -- it ( - - - �-- , FACE OF FACE OF ;_;'l, FACE OF :_ j SPRINKLER SPRINKLER SPRINKLER FITTING `- -J , - - FITTING ` ' FITTING -1 --,` - - \ ORDER LENGTHS: ORDER LENGTHS: ORDER LENGTHS: 3-1/2" to 48" 3-1/2" to 48" 2 -1/2" to 48" 1 -3/4" DIA. (88,9 to 1219,2 mm) (88,9 to 1219,2 mm) (63,5 to 1219,2 mm) (44,5 mm) IN 1/4" (6,4 mm) 2 -1/4" DIA. IN 1/4" (6,4 mm) 3" DIA. IN 1/4" (6,4 mm) INCREMENTS (57,2 mm) INCREMENTS (76,2 mm) INCREMENTS 1 FACE OF FACE OF yl M r, CEILING r■ 1 CEILING • 1 1 - �GI• .'/ /� . FACE OF 1 1 � '/ CEILING SO ■ SO 1 -3/8" ± 1/8" 2 -7/8" DIA. 1 -3/8" t 1/8" 3 -5/8" DIA. 2 -3/16" ± 1/8" 3" DIA. (34,9 t 3,2 mm) (73,0 mm) (34,9 t 3,2 mm) ( mm) (55,6 ± 3,2 mm) _ ( mm) FIGURE 3 FIGURE 4 FIGURE 5 TY3235 PENDENT TY3235 PENDENT TY3235 PENDENT w/ STANDARD RECESSED w/ WIDE FLANGE RECESSED w/ STANDARD ESCUTCHEON ESCUTCHEON ESCUTCHEON SPRINKLER FITTING SPRINKLER FITTING / (REFER TO DESIGN (REFER TO DESIGN TOP OF CRITERIA SECTION) 1 - -1 -1 CRITERIA SECTION) - -Z r - --, DEFLECTOR FACE OF :-.-41-- FACE OF : -1"` SPRINKLER L__L L S PRINKLER { _ "' FITTING FITTING --..___I ORDER LENGTHS: ` J ' J - 5" to 48" I (127,0 to 1219,2 mm) ORDER LENGTHS: 3 -1/2" DIA.--_{ IN 1/4" (6,4 mm) 1/2" to 46" (88,9 mm) I ORDER LENGTHS: INCREMENTS (12,7 to 1168,4 mm) IN 1/4 "(6,4 mm) 2 -1/2" DIA. 5" to 48" INCREMENTS (63,5 mm) (127,0 to 1219,2 mm) FACE OF I" 1 IN 1/4" (6,4 mm) /%• Illf INCREMENTS S FRTT NG R FACE OF 1 - CEILING MINIMUM 4 -1/4" t 1/8" _. 1 -3/4" (44,5 mm) !' (108,0 t 3,2 mm) DEFLECTOR TO CEILING SPRINKLER FITTING L ---r --- I I f f - (REFER TO DESIGN CRITERIA SECTION) FIGURE 6 FIGURE 7 FIGURE 8 TY3235 PENDENT TY3235 PENDENT TY3135 UPRIGHT w/ DEEP ESCUTCHEON w/o ESCUTCHEON w/o ESCUTCHEON Page 4 of 8 TFP51 O ORDER LENGTHS: Operation 2-1/2" to 48" (63,5 to 1219,2 mm) _ IN 1/4' (6,4 mm) INCREMENTS 4' i 1/8' (101,6 x 3,2 mm) When the Series DS -1 is in service, FACE OF FACE OF 1 -3/4' DIA. water is prevented from entering the — SPRINKLER MOUNTING — (44,5 mm) assembly by the Plug & Belleville Seal- __ -i L FITTING SURFACE \ ing Assembly (Ref. Figure 1) in the 1 Inlet of the Sprinkler. The glass Bulb ! � ll1!,;I dui i1 3" DIA. contains a fluid that expands when ex- i;I1 Jai I (76,2 mm) posed to heat. When the rated tem- r / 3.5° perature is reached, the fluid expands ' SPRINKLER FITTING sufficiently to shatter the glass Bulb, -' (REFER TO DESIGN CENTERLINE 5/16" and the Bulb Seat is released. The CRITERIA SECTION) OF WATERWAY (7,9 mm) compressed Spring is then able to ex- FIGURE 9 pand and push the Water Tube as well TY3335 HORIZONTAL SIDEWALL w/ STANDARD ESCUTCHEON as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug & Belleville ORDER LENGTHS: FACE OF Seal from the Inlet allowing the sprin- 1/2' to 45-3/4" (12,7 to 1162,1 mm) MOUNTING kler to activate and flow water. IN 1 /4' (6,4 mm) INCREMENTS SURFACE 4- 13/16 "± 1/8' (122,2 * 3,2 mm) FACE OF --"2-1/2" DIA. SPRINKLER (63,5 mm) -1 -i FITTING \ 1 Design " DIA. Criteria � ' �1I1I I • —I ' ii�ll hill / 3-1/2 (88,9 mm) The Series DS -1 Sprinklers are in- ,- - � 3.5° tended for use in fire sprinkler systems SPRINKLER FITTING NI designed in accordance with the -- -'--- (REFER TO DESIGN CENTERLINE 5/16' standard installation rules recognized CRITERIA SECTION) OF WATERWAY (7,9 mm) by the applicable Listing or Approval FIGURE 10 agency (e.g., UL Listing is based on TY3335 HORIZONTAL SIDEWALL w/ DEEP ESCUTCHEON NFPA 13 requirements). The Series DS -1 Dry Type Sprinkler is ORDER LENGTHS: to be installed in the 1 inch NPT outlet 5' to 48" (127,0 to1219,2mm) or run of malleable or ductile iron IN 1/4" (6,4 mm) INCREMENTS MINIMUM threaded tee fittings that meet the di- 2-1/4"(57,2mm) mensional requirements of ANSI DEFLECTOR TO ACE OF MOUNTING B16.3 (Class 150) or cast iron — SPRINKLER SURFACE threaded tee fittings that meet the di- _ 1 ( FITTING mensional requirements of ANSI B16.4 (Class 125) with the end sprin- ql, 'I ! kler fitting on a branch line to be i� � ! / Th7 plugged as shown in Figures 3 - 11. '- 3.5° 5/16" �� 79 6" When installing 1 inch NPT Series SPRINKLER FITTING (' DS -1 Dry Type Sprinklers on a dry pipe - = — ' (REFER TO DESIGN CENTERLINE sprinkler system, only use the side CRITERIA SECTION) OF WATERWAY outlet of maximum 2 -1/2 inch size re- FIGURE 11 ducing tee's. TY3335 HORIZONTAL SIDEWALL w/o ESCUTCHEON For wet pipe sprinkler systems, the Series DS -1 Dry Type Sprinklers may also be installed in the 1 inch NPT outlet of a Central Figure 730 Me- chanical Tee or the following Tyco Fire Products CPVC fittings: (P /N 80145) 1" x 1" NPT Female Adapter or (P /N 80249) 1 "x 1 "x 1" NPT Sprinkler Head Adapter Tee. NOTE Do not install the Series DS -1 into any other type fitting without first consult- ing the Technical Services Depart- ment. Failure to use the appropriate fitting may result in: failure of the sprin- kler to properly operate due to forma- tion of ice over the inlet Plug or binding of the inlet Plug; or, insufficient en- TFP510 Page 5 of 8 gagement of the inlet pipe threads with Deep Escutcheon, hold the outer consequent leakage. Installation piece in contact with the mounting sur- Branch, cross, and feedmain piping The Series DS -1 Dry Type Sprinklers piece (ceiling), approximately and then rotate the inner Sprinklers and sub- rY YP P piece approximately 1/4 turn with re- connected to Dry P must be installed in accordance with spect to the outer piece, to hold the ject to freezing temperatures must be the following instructions: Deep Escutcheon firmly together. pitched for drainage in accordance with the minimum requirements of the NOTES National Fire Protection Association The Series DS -1 must only be installed Care and for dry pipe sprinkler systems. in fittings that meet the requirements ■� When Dry Sprinklers are to be used in of the Design Criteria section. Maintenance wet pipe sprinkler systems protecting Refer to the Design Criteria section for The Series DS -1 Dry Type Sprinklers areas subject to freezing temperatures other important requirements regard- must be maintained and serviced in (e.g., sprinkler drops into freezers), ing piping design and sealing of the accordance with the following instruc- consideration must be given to the ap- clearance space around the Sprinkler tions: propriate length of the sprinkler that Casing. will prevent freezing of the water in the NOTES connecting pipes due to conduction. Do not install any bulb type sprinkler if When the temperature surrounding the bulb is cracked or there is a loss of Absence of the outer piece of an es- the wet pipe sprinkler system is main- liquid from the bulb. With the sprinkler cutcheon, which is used to cover a tained at a minimum temperature of held horizontally, a small air bubble clearance hole, may delay the time to 40 °F /4 °C, the following are the mini- should be present. The diameter of the sprinkler operation in a fire situation. mum recommended lengths between air bubble is approximately 1/16 inch Before closing a fire protection system the face of the sprinkler fitting and the (1,6 mm) for the 135 °F /57 °C rating to main control valve for maintenance outside surface of the protected area 1/8 inch (3,2 mm) for the 286 °F /141 °C work on the fire protection system that (i.e., length exposed to minimum am- rating. it controls, permission to shut down bient of 40 °F /4 °C): A leak tight 1 inch NPT sprinkler joint the affected fire protection systems • 12 inches (300 mm) when the tem- should be obtained with a torque of 20 must be obtained from the proper . perature within the protected area to 30 ft.lbs. (26,8 to 40,2 Nm). Higher authorities and all personnel who may is - 20 °F / -29 °C levels of torque may distort the sprin- be affected by this action must be no- kler inlet with consequent leakage or tilled. • 18 inches (450 mm) when the tem- impairment of the sprinkler. A Vent Hole is provided in the Bulb perature within the protected area p is - 40 °F / -40 °C Do not attempt to compensate for in- Seat (Ref. Figure 1) to indicate if the sufficient adjustment in an Escutcheon Dry Sprinkler is remaining dry. Evi- • 24 inches (600 mm) when the tem- Plate by under- or over- tightening the dence of leakage from the Vent Hole perature within the protected area Sprinkler. Readjust the position of the is an indication that there may be is -60°F/-51°C sprinkler fitting to suit. weepage past the Inlet seal and that For protected area temperatures be- S tep 1. P endent sprinklers must be the sprinkler needs to be removed for tween those given above, the minimum installed only in the pendent position, determining the cause of leakage (e.g. recommended length from the face of an improper installation or an ice plug) recom . rec ra ting to the outside h from the the pro- and upright sprinklers must be in- The fire protection system control tected area may be determined by in- stalled only in the upright position. The valve must be closed and the system terpolating between the indicated val- deflector of a pendent or upright sprin drained before removing the sprinkler. kler is to be parallel to the ceiling. ues. Sprinklers that are found to be leaking Horizontal sidewall sprinklers are to be or exhibiting visible signs of corrosion NOTE installed in the horizontal position with must be replaced. When Dry Sprinklers penetrate a ceil- their centerline of waterway perpen- ing or wall into an area subject to freez- dicular to the back wall and parallel to Automatic sprinklers must never be ing, the clearance space around the the ceiling. The word `TOP" on the De- painted, plated, coated, or otherwise Sprinkler Casing must be completely flector is to face towards the ceiling. altered after leaving the factory. Modi- sealed in order to prevent the leakage fied sprinklers must be replaced. of moist air into the freezing area Step 2 . With pipe thread sealant ap Sprinklers that have been exposed to which might result in the formation of plied to the inlet threads hand tighten corrosive products of combustion, but condensate around the Frame, Deflec the sprinkler into the sprinkler fitting have not operated, should be com- tor, Bulb Seat, or Bulb. Failure to pre- Step 3. Wrench tighten the sprinkler by pletely cleaned by wiping the sprinkler vent the formation of condensate could wrenching on the Casing with a pipe with a cloth or by brushing it with a soft result in the build -up of ice around the wrench whenever the casing is readily bristle brush. releasing components. This could re- accessible. Otherwise, use a W -Type 7 Care must be exercised to avoid dam - sult an inadvertent operation of the Sprinkler Wrench (Ref. Figure 2). The age - before, during, and after instal - sprinkler or impaired operation due to wrench recess of the W -Type 7 is to be lation. Sprinklers damaged by drop - reduced thermal sensitivity. applied to the sprinkler wrench flats ping, striking, wrench twist/slippage, (Ref. Figure 2). or the like, must be replaced. Also, Step 4. After the ceiling /wall has been replace any sprinkler that has a installed /finished, slide on the outer cracked bulb or that has lost liquid from piece of the Escutcheon until it comes its bulb (Ref. Installation Section). in contact with the ceiling /wall. Do not The owner is responsible for the in- lift the ceiling panel out of its normal spection, testing, and maintenance of position. their fire protection system and de- In the case of the outer piece of the vices in compliance with this docu- Page 6 of 8 TF51O ment, as well as with the applicable MADE IN LIEU OF ANY AND ALL standards of the National Fire Protec- OTHER WARRANTIES EXPRESS OR tion Association (e.g., NFPA 25), in IMPLIED. INCLUDING WARRANTIES addition to the standards of any other OF MERCHANTABILITY AND FIT - authorities having jurisdiction. The in- NESS FOR A PARTICULAR PUR- stalling contractor or sprinkler manu- POSE. facturer should be contacted relative to any questions. It is recommended that automatic Ordering sprinkler systems be inspected, tested, and maintained by a qualified Procedure Inspection Service in accordance with local requirements and /or national Contact your local distributor for avail - codes. ability, and please specify the follow- ing: Limited 1. Sprinkler. Warranty • Model /SIN. • Quick Response, Standard Cover - Products manufactured by Tyco Fire age, Dry Type Sprinkler Products are warranted solely to the • Deflector Style. original Buyer for ten (10) years against defects in material and work- • 5.6 K- factor. manship when paid for and properly • Order Length. installed and maintained under normal use and service. This warranty will ex- Dry Type Sprinklers are furnished pire ten (10) years from date of ship- based upon Order Length as ment by Tyco Fire Products. No war- measured per Figure 3 through ranty is given for products or 11, as applicable. After the meas- components manufactured by comps- urement is taken, round it to the nies not affiliated by ownership with nearest 1/4 inch increment. Tyco Fire Products or for products and components which have been subject • Inlet Connection (1 Inch NPT or to misuse, improper installation, corro- ISO 7 -R1). sion, or which have not been installed, • Temperature Rating. maintained, modified or repaired in ac- cordance with applicable Standards of • Sprinkler Finish. the National Fire Protection Associa- • Escutcheon Style and Finish, as tion, and /or the standards of any other applicable. Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be • Part Number from Table B. (Part defective shall be either repaired or numbers are for 1 inch NPT stand - replaced, at Tyco Fire Products' sole _ and order sprinklers. Orders for all option. Tyco Fire Products neither as- other sprinkler assemblies must sumes, nor authorizes any person to be accompanied by a complete assume for it, any other obligation in description.) connection with the sale of products or 2. W -Type 7 Sprinkler Wrench. parts of products. Tyco Fire Products shall not be responsible for sprinkler Refer to the Price List for complete system design errors or inaccurate or listing of Part Numbers. incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS TFP510 Page 7 of 8 P/N 60 - XXX - X - XXX 1 ORDER . LENGTH (1) (EXAMPLES) 055 5.50" SPRINKLER ESCUTCHEON MODEUSIN FINISH FINISH (2) 082 8.25" 36 Pendent w/ Standard TY3235 1 NATURAL BRASS WHITE 180 18.00" Escutcheon (1" NPT) (Fig. 5) 4 WHITE POLYESTER WHITE 187 18.75" 33 Pendent w/ Deep TY3235 Escutcheon (1" NPT) (Fig. 6) 9 CHROME PLATED CHROME PLATED 372 37.25" 37 Pendent w/ Std. Recessed TY3235 0 CHROME PLATED WHITE 480 48.00" Escutcheon (1" NPT) (Fig. 3) 3 WHITE (RAL9010)" WHITE (RAL9010)" 32 Pendent w/o Escutcheon TY3235 Escutcheon (1" NPT) (Fig. 7) TEMPERATURE 34 Sidewall w/ Standard TY3335 I RATING (3) Escutcheon (1" NPT) (Fig. 9) 0 135F/57C 43 Sidewall w/ Deep TY3335 Escutcheon (1" NPT) (Fig. 10) 1 155F/68C 44 Sidewall w/o TY3335 2 175F/79C Escutcheon (1" NPT) (Fig. 11) 3 200F/93C 4 286F/141C 38 Upright w/o Escutcheon TY3135 - (1" NPT) (Fig. 8) NOTES (1). Dry Type Sprinklers are furnished based upon "Order Length" as measured per Figures 3 through 11, as applicable, and for each individual sprinkler where it is to be installed. After the meas- urement is taken, round it to the nearest 1/4 inch increment. (2). Escutcheon Finish applies to sprinklers provided with escutcheons. (3). The 286F/141C temperature rating applies to non - recessed sprinkler assemblies. * Eastern Hemisphere sales only. • TABLE B PART NUMBER SELECTION SERIES DS -1, QUICK RESPONSE, STANDARD COVERAGE, DRY TYPE SPRINKLERS (Use Prefix "1" for ISO 7 -R1 Connection, e.g., I -60 -361 -1 -180) Page 8 of 8 TF51O TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqCD /Ffre & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series TY -FRB — 5.6 K- factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General ment provided by the Recessed Es- cutcheon reduces the accuracy to Description which the fixed pipe nipples to the sprinklers must be cut. The Series TY -FRB, 5.6 K- Factor, Corrosion resistant coatings, where Horizontal and Vertical Sidewall Sprin- applicable, are utilized to extend the klers described in this data sheet are life of copper alloy sprinklers beyond °! quick response - standard coverage, that which would otherwise be ob -, " 9 ,, decorative 3 mm glass bulb type spray tained when exposed to corrosive at- sprinklers designed for use in light and mospheres. Although corrosion resis- __..... ordinary hazard, commercial occupan- tant coated sprinklers have passed the cies such as banks, hotels, shopping standard corrosion tests of the appli- malls, etc. They are designed for in- cable approval agencies, the testing is stallation along a wall or the side of a not representative of all possible cor- beam and just beneath a smooth ceil rosive atmospheres. Consequently, it ing. Sidewall sprinklers are commonly is recommended that the end user be 7 ' used instead of pendent or upright consulted with respect to the suitability sprinklers due to aesthetics or building of these coatings for any given corro construction considerations, where sive environment. The effects of ambi- ent temperature, concentration of ab le ing across the ceiling is not desir chemicals, and gas /chemical velocity, should be considered, as a minimum, The recessed version of the Series - TY -FRB Horizontal Sidewall Sprinkler chemical to which the sprinklers will be .:r—"°" along with the corrosive nature of the is intended for use in areas with a exposed. finished wall. It uses a two -piece Style , 10 Recessed Escutcheon with 1/2 inch WARNINGS (12,7 mm) of recessed adjustment or The Series TY -FRB Sprinklers de- up to 3/4 inch (19,1 mm) of total adjust- scribed herein must be installed and ment from the flush sidewall position, maintained in compliance with this or a two -piece Style 20 Recessed Es- document, as well as with the applica- cutcheon with 1/4 inch (6,4 mm) of ble standards of the National Fire Pro- Technical recessed adjustment or up to 1/2 inch tection Association, in addition to the Data (12,7 mm) of total adjustment from the standards of any other authorities hay- flush sidewall position. The adjust- ing jurisdiction. Failure to do so may Approvals impair the performance of these de- UL and C -UL Listed. vices. FM, LPCB, and NYC Approved. The owner is responsible for maintain- (Refer to Table A for complete ap- ing their fire protection system and de- proval information including corrosion IMPORTANT vices in proper operating condition. resistant status.) The installing contractor or sprinkler Maximum Workin Pressure Always refer to Technical Data manufacturer should be contacted g Refer to Table B. Sheet TFP700 for the "INSTALLER with any questions. WARNING" that provides cautions Discharge Coefficient with respect to handling and instal- N lOdel�Sprinkler K = 5.6 GPM /psi (80,6 LPM /bar lation of sprinkler s stems and corn- Temperature Ratings ponents. Improper handling and in- P 9 stallation can permanently damage Identification Refer to Table A. a sprinkler system or its compo- Finishes nents and cause the sprinkler to fail Numbers Sprinkler: Refer to Table A. to operate in a fire situation or cause Recessed Escutcheon: White Coated, it to operate prematurely. TY3331 - Horizontal Chrome Plated, or Brass Plated. TY3431 - Vertical Page 1 of 6 APRIL, 2006 TFP176 Page 2 of 6 TFP176 SPRINKLER FINISH (See Note 11) K TYPE TEMP. BULB NATURAL CHROME WHITE"** LEAD LIQUID BRASS PLATED POLYESTER COATED 135 °F /57 °C Orange HORIZ. 155 °F /68 °C Red SIDEWALL 1, 2, 3, 4, 9, 10 1, 2, 3, 9 1, 2, 3, 9 (TY3331) 175 °F /79 °C Yellow 200 °F /93 °C Green 5.6 286 °F /141 °C Blue 1/2" NPT RECESSED 135 °F /57 °C Orange HORIZ. 155 °F /68 °C Red SIDEWALL 1, 2, 4, 9, 10 1, 2, 9 N/A (TY3331)* 175 °F /79 °C Yellow Figure 3 200F/93°C Green RECESSED 135 °F /57 °C Orange HORIZ. 155 °F /68 °C Red SIDEWALL 1, 2, 3, 4, 9 N/A (TY3331) ** 175 °F /79 °C Yellow Figure 4 200 °F /93 °C Green VERTICAL 135 °F /57 °C Orange SIDEWALL 155 °F /68 °C Red 5.6 (TY3431) 5, 6, 7, 8, 9 5, 6, 7, 9 1/2" Installed 175 °F /79 °C Yellow NPT Pendent 200 °F /93 °C Green or Upright 286 °F /141 °C Blue NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. 2. Listed by Underwriters Laboratories Inc. for use in Canada (C -UL) as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers for use in Light Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007a/04) at a 4 to 6 inch (100 to 150 mm) top of deflector to ceiling distance. The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 5. Listed by Underwriters Laboratories, Inc. as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. 6. Listed by Underwriters Laboratories for use in Canada (C -UL) as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. 7. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers for use in Light Hazard Occupancies. 8. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06 & 007a/04) as Quick Response Sprinklers. 9. Approved by the City of New York under MEA 354 -01 -E. 10. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) at a 4 to 6 inch (100 to 150 mm) top of deflector to ceiling distance. The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. 11. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) 3/4" Total Adjustment Recessed Escutcheon. ** Installed with Style 20 (1/2" NPT) 1/2" Total Adjustment Recessed Escutcheon. * ** Frame and deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS Physical Characteristics Frame Bronze Operation Button Brass /Copper Sealing Assembly The glass Bulb contains a fluid which F- Beryllium Nickel w /Teflont expands when exposed to heat. When Bulb Glass the rated temperature is reached, the Compression Screw Bronze fluid expands sufficiently to shatter the o, HSW Deflector Bronze glass Bulb, allowing the sprinkler to VSW Deflector Copper activate and water to flow. Patents o a U.S.A. 5,810,263 7 TFP176 Page 3 of 6 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED POLYESTER COATED HORIZONTAL SIDEWALL 250 PSI (17,2 BAR) (TY3331) OR 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 5.6 RECESSED HORIZ. 1/2" SIDEWALL (TY3331) (SEE NOTE 1) N/A NPT VERTICAL SIDEWALL (TY3431) 175 PSI (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C -UL); and, the Approval by the City of New York. TABLE B, MAXIMUM WORKING PRESSURE Design * Temperature rating is DEFLECTOR indicated on deflector or HAT 5 Criteria adjacent to orifice seat t gat # 011 6 on frame. The Series TY -FRB Horizontal and * * Pipe thread Vertical Sidewall Sprinklers are in- connections per ISO 7/1 / Vap\ tended for fire protection systems de- can be provided on signed in accordance with the stand- special request. and installation rules recognized by the 6 4 2 3 1 applicable Listing or Approval agency (e.g., UL Listing is based on the re 9/16" WRENCH 1/2" quirements of NFPA 13, and FM Ap (14,3 mm) FLATS NPT proval is based on the requirements of _ FM's Loss Prevention Data Sheets). r — Only the Style 10 or 20 Recessed Es- _ emu II � / Il � ETZEi IIIII�I��IIIIIY for recessed d horizontal tal applicable, installations. lations. be used 1.111, O — �I ' nII1IIIII111111 I� for recessed orizonal sal � , � =; �I • 1- 13/16" 7/16" (46,0 mm) (11,1 mm) - CENTERLINE NOMINAL OF SPRINKLER MAKE -IN WATERWAY 1-1/2" _ (38,1 mm) 2- 3/16" (55,6 mm) 1 - Frame STYLE ESCUTCHEON 2 - Button 3 - Sealing 10 or 20 — PLATE SEATING Assembly RECESSED I SURFACE 4 - Bulb ESCUTCHEON 5 - Compression Screw ■ 6 - Deflector 2-7/8" DIA. II■(411,1IIIIIIIIIIII (73,0 mm) � 4 1M111 I FIGURE 1 5.6 K- FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS Page 4 of 6 TFP176 Installation ARROW MUST POINT AWAY The Series TY -FRB Sprinklers must 7/16" FROM AND BE O kw- 0 be installed in accordance with the fol- ESCUTCHEON (11,1 mm) PERPENDICULAR lowing instructions: PLATE SEATING ** NOMINAL TO THE BACK SURFACE NPT MAKE -IN WALL SURFACE 4 NOTES Do not install any bulb type sprinkler if *6 s -�� -t the bulb is cracked or there is a loss of * liquid from the bulb. With the sprinkler I IIIL � _ f _ '..,, ; 5 held horizontally, a small air bubble 2 - 3/16" �� } IM 2 - 3/16" I should be present. The diameter of the (55,6 mm) /IL \I► (55,6 mm) 4 air bubble is approximately 1/16 inch i `III J ` (1,6 mm) for the 135F/57°C to 3/32 1.1/2 � r ` � 2 inch (2,4 mm) for the 286 °F /141 °C WRENCH �� temperature ratings. (38,--u2 - FLATS 7 p 3 A leak tight 1/2 inch NPT sprinkler joint z� ^� YYY• should be obtained with a torque of 7 1 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- SHOWN SHOWN CROSS mum of21 ft. lbs. (28,5 Nm) of torque PENDENT UPRIGHT SECTION may be used to install sprinklers with 1/2 NPT connections. Higher levels of torque may distort the sprinkler and 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector cause leakage or impairment of the 2 - Button Assembly 5 - Compression 7- Ejection Spring sprinkler. Screw Do not attempt to make -up for insuffi- cient adjustment in the escutcheon * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. plate by under or over - tightening the * *Pipe thread connections per ISO 7/1 can be provided on special request. sprinkler. Readjust the position of the sprinkler fitting to suit. FIGURE 2 The Series TY -FRB Horizontal and 5.6 K- FACTOR QUICK RESPONSE Vertical Sidewall Sprinklers must be SERIES TY -FRB VERTICAL SIDEWALL (TY3431) SPRINKLERS installed in accordance with the follow- ing instructions. Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of water- Step B. After installing the Style 10 or Care and way perpendicular to the back wall and 20 Mounting Plate over the sprinkler parallel to the ceiling. The word "TOP" threads, hand tighten the sprinkler into on the Deflector is to face towards the the sprinkler fitting. Maintenance ceiling. Step C. Tighten the sprinkler into the Vertical sidewall sprinklers are to be sprinkler fitting using only the W -Type The maintained and ance with the following g i instructions: accord- n - installed in the pendent or upright po- 7 Recessed Sprinkler Wrench (Ref. nd s e sition with the arrow on the Deflector Figure 6). With reference to Figure 1, s: pointing away from the wall. the W -Type 7 Recessed Sprinkler NOTES Step 2. With pipe thread sealant ap- Wrench is to be applied to the sprinkler Before closing a fire protection system plied to the pipe threads, hand tighten wrench flats. main control valve for maintenance the sprinkler into the sprinkler fitting. Step D. After the ceiling has been in- work on the fire protection system that Step 3. Tighten the sprinkler into the stalled or the finish coat has been ap- it controls, permission to shut down sprinkler fitting using only the W-Type plied, slide on the Style 10 or 20 Clo- the affected fire protection system 6 Sprinkler Wrench (Ref. Figure 5), sure over the Series TY -FRB Sprinkler must be obtained from the proper With reference to Figure 1 or 2, the and push the Closure over the Mount- authorities and all personnel who may W-Type 6 Sprinkler Wrench is to be ing Plate until its flange comes in con- be affected by this action must be no- applied to the wrench flats. tact with the ceiling tified. The Series TY -FRB Recessed Hori- The owner must assure that the sprin- zontal Series TY-FRB Sprinklers must be k/ers are not used for hanging of any installed in accordance with the follow- objects; otherwise, non - operation in ing instructions. the event of a fire or inadvertent opera- tion may result. Step A. Recessed horizontal sidewall Absence of an escutcheon, which is sprinklers are to be installed in the horizontal position with their centerline used to cover a clearance hole, may of waterway perpendicular to the back delay the time to sprinkler operation in wall and parallel to the ceiling. The a fire situation. word "TOP" on the Deflector is to face Sprinklers that are found to be leaking towards the ceiling. or exhibiting visible signs of corrosion TFP176 Page 5 of 6 y - 5/8 ±1/4" Lc (15,9 ±6,4 mm) MOUNTING FACE OF WRENCH RECESS "A" USED FOR SURFACE SPRINKLER ^ ( 1 2" NPT MODELS) FITTING FIGURE 5 CLOSURE / – W -TYPE 6 SPRINKLER WRENCH ..101,Ng 2 -7/8" DIA. SERIES (73,0 mm) WRENCH RECESS TY -FRB i 2 -1/4" DIA. (57,2 mm) / � MOUNTING I � P Ar LATE / y , 1/8" PUSH WRENCH (3,2 mm) IN TO ENSURE ENGAGEMENT 1 -1/4" (31,8 mm) 3/4" (19,1 mm) WITH SPRINKLER 3/4" (19,1 mm) 1/4" (6,4 mm) WRENCHING AREA FIGURE 3 FIGURE 6 SERIES TY -FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER W -TYPE 7 RECESSED WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT SPRINKLER WRENCH STYLE 10 RECESSED ESCUTCHEON y 1/2 ±1/8" must be replaced. (12,7 ±3,2 mm) Automatic sprinklers must never be painted, plated, coated or otherwise MOUNTING FACE OF altered after leaving the factory. Modi- SURFACE SPRINKLER fled sprinklers must be replaced. FITTING Sprinklers that have been exposed to corrosive products of combustion, but A have not operated, should be replaced I if they cannot be completely cleaned by wiping the sprinkler with a cloth or –411_,—,1 2 -7 / 8 " DIA. by brushing it with a soft bristle brush. SERIES (73,0 mm) Care must be exercised to avoid dam- age to the sprinklers - before, during, TY FRB t 111rAlril _- 2-1/4" mm) 4" DIA. and after installation. Sprinklers dam - (57,2 aged by dropping, striking, wrench twist/slippage, or the like, must be re- `� j placed. Also, replace any sprinkler MOUNTING , that has a cracked bulb or that has lost PLATE % . liquid from its bulb. (Ref. Installation Section). y Frequent visual inspections are rec- 1/8" ommended to be initially performed for (3,2 mm) corrosion resistant Boated sprinklers, after the installation has been com- 1-1/4" (31,8 mm) 1/2" (12,7 mm) pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, 1" (25,4 mm) 1/4" (6,4 mm) annual inspections per NFPA 25 should suffice; however, instead of in- FIGURE 4 specting from the floor level, a random SERIES TY -FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER sampling of close -up visual inspec- WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT tions should be made, so as to better STYLE20 RECESSED ESCUTCHEON determine the exact sprinkler condi- tion and the long term integrity of the Page 6 of 6 TFP176 P/N 57 - XXX - X - XXX I i SPRINKLER TEMPERATURE MODEUSIN RATING 378 HORIZONTAL SIDEWALL TY3331 1 NATURAL BRASS 135 135 °F /57 °C 375 VERTICAL SIDEWALL TY3431 4 WHITE POLYESTER 155 155F/68°C 3 WHITE RAL9010)* 175 175 °F /79 °C 9 CHROME PLATED 200 200 °F /93 °C 7 LEAD COATED 286 286 °F /141 °C TABLE C * Eastern Hemisphere sales only. PART NUMBER SELECTION SERIES TY -FRB HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS corrosion resistant coating, as it may standards of any other Authorities be affected by the corrosive conditions Having Jurisdiction. Materials found Ordering present. by TFBP to be defective shall be either repaired or replaced, at TFBP's sole P rocedure The owner is responsible for the in- option. TFBP neither assumes, nor spection, testing, and maintenance of authorizes any person to assume for it, When placing an order, indicate the their fire protection system and de- any other obligation in connection with full product name. Refer to the Price vices in compliance with this docu- the sale of products or parts of prod- List for complete listing of Part Num- ment, as well as with the applicable ucts. TFBP shall not be responsible for bers. standards of the National Fire Protec- sprinkler system design errors or inac- Contact your local distributor for avail - tion Association (e.g., NFPA 25), in curate or incomplete information sup- ability. addition to the standards of any other plied by Buyer or Buyer's repre- authorities having jurisdiction. The in- sentatives. Sprinkler Assemblies with NPT stalling contractor or sprinkler manu In no event shall TFBP be liable, in Thread Connections: facturer should be contacted relative t t conrac, tort, strict liability or under Specify: (Specify Model/SIN), any questions. y ( p y ). Quick any other legal theory, for incidental, Response, (specify K- factor), (specify It is recommended that automatic indirect, special or consequential dam- temperature rating), Series TY -FRB sprinkler systems be inspected, ages, including but not limited to labor (specify Horizontal Sidewall or Vertical tested, and maintained by a qualified charges, regardless of whether TFBP Sidewall) Sprinkler with (specify type Inspection Service in accordance with was informed about the possibility of of finish or coating), P/N (specify from local requirements and /or national such damages, and in no event shall Table C). codes. TFBP's liability exceed an amount equal to the sales price. Recessed Escutcheon: Limited The foregoing warranty is made in lieu E cu t ch 20) Recessed Ess cutch of any and all other warranties. ex- eoon n with ( (spee cify *) finish, P/N press or implied. including warranties (specify *). Warranty 9 p � 9 of merchantability and fitness for a par- * Refer to Technical Data Sheet TFP770. Products manufactured by Tyco Fire & ticular purpose. Building Products (TFBP) are war- This limited warranty sets forth the ex- Sprinkler Wrench: ranted solely to the original Buyer for clusive remedy for claims based on Specify: W -Type 6 Sprinkler Wrench, ten (10) years against defects in mate- failure of or defect in products, materi- P/N 56- 000 -6 -387. rial and workmanship when paid for als or components, whether the claim and properly installed and maintained is made in contract, tort, strict liability pecify: W-Type 7 Sprinkler Wrench, under normal use and service. This y P/N 56- 8550 0-4 001. warranty will expire ten (10) years or any other legal theory. from date of shipment by TFBP. No This warranty will apply to the full ex- warranty is given for products or com- tent permitted by law. The invalidity, in ponents manufactured by companies whole or part, of any portion of this not affiliated by ownership with TFBP warranty will not affect the remainder. or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and /or the TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Fire Station #1 Drawing Date:5 /29/09 5/29/09 13:40 HYDRAULIC DESIGN INFORMATION SHEET Job Name: Fire Station #1 Location: 6907 Dairy Road Zephyrhills, Florida 33542 Drawing Date: 5/29/09 Remote Area Number: 1 Contractor: SimplexGrinnell LP Telephone:813- 626 -5482 4701 Oak Fair Blvd. Tampa, Florida 33610 Designer: Al Strickland Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Existing Occupancy:Fire Station Reviewing Authorities:NFPA 13 & Local Fire Marshal SYSTEM DESIGN Code:NFPA 13 Hazard:Ordinary GI System Type:WET Area of Sprinkler Oper. 1056 sq ftl Sprinkler or Nozzle Density (gpm /sq ft) 0.150 I Make: TYCO Area per Sprinkler 130.0 sq ftl Model: TY -FRB Hose Allowance Inside 100 gpm I K- Factor: 5.60 Hose Allowance Outside 150 gpm I Temperature Rating: 155 CALCULATION SUMMARY 10 Flowing Outlets gpm Required: 474.6 psi Required: 39.7 @ Source WATER SUPPLY Water Flow Test 1 Pump Data Date of Test 4/29/2009 I Rated Capacity 0 gpm I Static Pressure 56.0 psi I Rated Pressure 0.0 psi 1 Residual Pres 40.0 psi I Elevation 0 At a Flow of 1060 gpm I Make: Elevation 0" I Model: Location: Fire Hydrant South Of The Statio Source of Information: Zephyrhills Fire Department SYSTEM VOLUME 157 Gallons Notes: Apparatus Bay Lower Area JAMES M. CURT 379i2 8 '9 7. A' 5 3`'•/ a n n 41 / 29775 AYH AD RD. DADS CITY, FL 33523 Fire Station #1 Drawing Date:5 /29/09 5/29/09 13:40 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 1 225 21.9 psi 1 Pipe 4" 10x21 18' 120 4.260 225 0.2 1 4" Grvd Shotgun Valve "90" 21' 120 4.026 225 0.3 1 4" Grvd Butterfly Valve "BFV" 14' 120 4.026 225 0.2 Elevation Change 21'0" 9.1 Fixed Flow Flow Loss 100 gpm Hydr Ref R1 Required at Base Of Riser 325 31.8 psi 1 Pipe 4" 10x21 2' 120 4.260 325 0.0 1 4" "GF" Adapter 0' 120 4.026 325 0.0 1 6" Grvd 90 Ell 14' 120 6.065 325 0.1 1 Pipe 6" 10x21 3' 120 6.357 325 0.0 1 6" Grvd 90 Ell 14' 120 6.065 325 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 325 0.0 1 6" MJ 90 Ell 14' 120 6.065 325 0.1 1 Pipe 6" DIx18 America DI 350 75' 140 6.338 325 0.2 1 6" MJ 45 Ell 7' 120 6.065 325 0.0 1 Pipe 6" DIx18 01 350 50' 140 6.338 325 0.1 1 6" MJ 45 Ell 7' 120 6.065 325 0.0 1 Pipe 6" DIx18 America DI 350 10' 140 6.338 325 0.0 1 6" MJ 90 Ell 14' 120 6.065 325 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 325 0.0 1 6" Flngd 90 Ell 14' 120 6.065 325 0.1 1 6" Flngd Gate Valve Kennedy "4068A" 3' 120 6.065 325 0.0 1 6" Flngd Back Flow Valve Ames "3000 CHART LOSS 325 6.8 1 6" Flngd Gate Valve Kennedy "4068A" 3' 120 6.065 325 0.0 1 6" Flngd 90 Ell 14' 120 6.065 325 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 325 0.0 1 6" MJ 90 Ell 14' 120 6.065 325 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 325 0.0 1 6" MJ 90 Ell 14' 120 6.065 325 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 325 0.0 1 12" MJ Tee 60' 120 11.938 325 0.0 1 Pipe 12" DIx18 01 350 150' 140 12.578 325 0.0 Fixed Flow Flow Loss 150 gpm Hydr Ref R2 Required at Source 475 39.7 psi Water Source 56.0 psi static, 40.0 psi residual @ 1060 gpm 475 gpm 52.4 psi SAFETY PRESSURE 12.7 psi Available Pressure of 52.4 psi Exceeds Required Pressure of 39.7 psi This is a safety margin of 12.7 psi or 24 % of Supply Maximum Water Velocity is 16.1 fps Fire Station #1 Drawing Date:5 /29/09 5/29/09 13:40 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee ✓ Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. K FACTOR Flow factor for open head or path where Flow (gpm) = K x - \/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf /ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q /C) ^1.85 / ID ^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q ^2 /ID ^4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Fire Station #1 Drawing Date:5 /29/09 5/29/09 13:40 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K- FACTOR FLOW FLOW DENSITY (FT) (GPM /(PSI^ )) (PSI) (GPM) (GPM) (GPM /SQ.FT) 101 17.83 14.5 1015 16.50 5.60 14.1 21.0 19.5 0.16 102 17.83 15.9 102S 16.50 5.60 15.5 22.0 19.5 0.17 103 17.83 17.4 1035 16.50 5.60 16.9 23.0 19.5 0.18 104 17.83 18.9 1045 16.50 5.60 18.3 23.9 19.5 0.18 105 17.83 20.8 105S 16.50 5.60 20.1 25.1 19.5 0.19 106 17.83 12.3 106S 16.50 5.60 12.1 19.5 19.5 0.15 107 17.83 13.6 1075 16.50 5.60 13.3 20.4 19.5 0.16 108 17.83 14.8 1085 16.50 5.60 14.5 21.3 19.5 0.16 109 17.83 17.5 1095 16.50 5.60 17.0 23.1 19.5 0.18 110 17.83 20.8 1105 16.50 5.60 20.1 25.1 19.5 0.19 230 17.83 20.0 231 17.83 17.3 232 17.83 16.2 A3 17.83 21.0 A4 17.83 21.1 W 17.83 21.9 Max velocity of 16.15 occurs in the pipe from 102 TO 232 Nodes with "S" indicate a node at the top of a sprig or bottom of drop pendent. The node without an "S" is on the branch. Fire Station #1 Drawing Date:5 /29/09 5/29/09 13:40 Tyco Fire Products Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 106 TO W (PRIMARY PATH) 19.50 1.049 1T 1.33 12.1 12.1 K = 5.60 106S C =120 5.00 -0.6 0.0 19.50 0.124 6.33 0.8 12.1 Vel = 7.31 1.049 10.00 12.3 12.3 EqK = 5.55 106 0=120 0.00 0.0 0.0 19.50 0.124 10.00 1.2 12.3 Vel = 7.31 20.42 1.380 10.00 13.6 13.6 EqK = 5.54 107 0=120 0.00 0.0 0.0 39.92 0.123 10.00 1.2 13.6 Vel = 8.65 21.29 1.380 10.00 14.8 14.8 EqK = 5.53 108 C =120 0.00 0.0 0.0 61.21 0.271 10.00 2.7 14.8 Vel = 13.26 23.10 1.610 1T 7.32 17.5 17.5 EqK = 5.52 109 C =120 8.00 0.0 0.0 84.31 0.231 15.32 3.5 17.5 Vel = 13.42 140.25 4.260 1E 53.18 21.1 21.1 A4 C =120 13.17 0.0 0.0 See PATH 2 AND 4 224.57 0.012 66.35 0.8 21.1 Vel = 5.10 W 224.57 21.9 K = 48.01 20.42 1.049 1T 1.33 13.3 13.3 K = 5.60 107S 0=120 5.00 -0.6 0.0 20.42 0.135 6.33 0.9 13.3 Vel = 7.65 107 20.42 13.6 K = 5.54 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Fire Station #1 Drawing Date:5 /29/09 5/29/09 13:40 Tyco Fire Products Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn 21.29 1.049 1T 1.33 14.5 14.5 K = 5.60 108S 0=120 5.00 -0.6 0.0 21.29 0.146 6.33 0.9 14.5 Vel = 7.98 108 21.29 14.8 K = 5.53 23.10 1.049 1T 1.33 17.0 17.0 K = 5.60 1095 0=120 5.00 -0.6 0.0 23.10 0.170 6.33 1.1 17.0 Vel = 8.66 109 23.10 17.5 K = 5.52 PATH 2 FROM HYDRAULIC REFERENCE 101 TO A4 21.05 1.049 1T 1.33 14.1 14.1 K = 5.60 1015 0=120 5.00 -0.6 0.0 21.05 0.143 6.33 0.9 14.1 Vel = 7.89 1.049 10.00 14.5 14.5 EqK = 5.54 101 0=120 0.00 0.0 0.0 21.05 0.143 10.00 1.4 14.5 Vel = 7.89 22.03 1.049 0.50 15.9 15.9 EqK = 5.53 102 0=120 0.00 0.0 0.0 43.08 0.538 0.50 0.3 15.9 Vel = 16.15 1.380 8.00 16.2 16.2 232 0=120 0.00 0.0 0.0 43.08 0.142 8.00 1.1 16.2 Vel = 9.33 1.610 1.50 17.3 17.3 231 0=120 0.00 0.0 0.0 43.08 0.067 1.50 0.1 17.3 Vel = 6.85 23.02 1.610 10.00 17.4 17.4 EqK = 5.52 103 0=120 0.00 0.0 0.0 66.09 0.147 10.00 1.5 17.4 Vel = 10.52 23.95 1.610 4.50 18.9 18.9 EqK = 5.51 104 0=120 0.00 0.0 0.0 90.04 0.261 4.50 1.2 18.9 Vel = 14.33 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Fire Station #1 Drawing Date:5 /29/09 5/29/09 13:40 Tyco Fire Products Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 2 FROM HYDRAULIC REFERENCE 101 TO A4 CONTINUED 2.067 1T 2.82 20.0 20.0 230 0=120 10.00 0.0 0.0 90.04 0.077 12.82 1.0 20.0 Vel = 8.69 25.10 4.260 9.67 21.0 21.0 A3 C =120 0.00 0.0 0.0 See PATH 3 115.14 0.004 9.67 0.0 21.0 Vel = 2.62 A4 115.14 21.1 K = 25.09 22.03 1.049 1T 1.33 15.5 15.5 K = 5.60 102S 0=120 5.00 -0.6 0.0 22.03 0.156 6.33 1.0 15.5 Vel = 8.26 102 22.03 15.9 K = 5.53 23.02 1.049 1T 1.33 16.9 16.9 K = 5.60 103S 0=120 5.00 -0.6 0.0 23.02 0.169 6.33 1.1 16.9 Vel = 8.63 103 23.02 17.4 K = 5.52 23.95 1.049 1T 1.33 18.3 18.3 K = 5.60 104S 0=120 5.00 -0.6 0.0 23.95 0.182 6.33 1.1 18.3 Vel = 8.98 104 23.95 18.9 K = 5.51 PATH 3 FROM HYDRAULIC REFERENCE 105 TO A3 25.10 1.049 1T 1.33 20.1 20.1 Y = 5.60 105S 0=120 5.00 -0.6 0.0 25.10 0.198 6.33 1.3 20.1 Vel = 9.41 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Fire Station #1 Drawing Date:5 /29/09 5/29/09 13:40 Tyco Fire Products Page 8 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 3 FROM HYDRAULIC REFERENCE 105 TO A3 CONTINUED 1.610 1T 2.68 20.8 20.8 EqK = 5.51 105 0=120 8.00 0.0 0.0 25.10 0.025 10.68 0.3 20.8 Vel = 3.99 A3 25.10 21.0 K = 5.47 PATH 4 FROM HYDRAULIC REFERENCE 110 TO A4 25.12 1.049 1T 1.33 20.1 20.1 K = 5.60 110S 0=120 5.00 -0.6 0.0 25.12 0.198 6.33 1.3 20.1 Vel = 9.42 1.610 1T 2.68 20.8 20.8 EqK = 5.51 110 0=120 8.00 0.0 0.0 25.12 0.025 10.68 0.3 20.8 Vel = 4.00 A4 25.12 21.1 K = 5.47 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) O 1 , Q • ' I o Ln I I I 1 1 E E CD QQ 0) m X 00 I 1 3 O'0 1 A A i . 0 i O a ! a) ai 7 1 O (O 2 E0 1 7) Q Q cn u) 1 , Q rn CT) Q Q 6 N LO N( O co N N E ! O Q I I M ai m : O O 00 1.0 1 LL v �_ ,_> L = E EaLu i O O co _E -c I 'N '5 Q F- 1 Q Q a) 4- I O O O 0 1 I n O r O ilj I c I O N N 0 ,_ Lo O O - 0 , , N (/) s_ N >, N d 0) 2 a - v r +. di D O O (6 O O O 1 I N N , co I i co 1 co O 2 L� O -, Ix LL (0 N ! O Q .,(T > O N. N (=;) Q N O .� 6) N O - ) LL CONCC ! o c O O O O O Ln V co N 11 cn— Fire Station #1 Drawing Date:5 /29/09 5/29/09 13:21 HYDRAULIC DESIGN INFORMATION SHEET Job Name: Fire Station #1 Location: 6907 Dairy Road Zephyrhills, Florida 33542 Drawing Date: 5/29/09 Remote Area Number: 2 Contractor: SimplexGrinnell LP Telephone:813- 626 -5482 4701 Oak Fair Blvd. Tampa, Florida 33610 Designer: Al Strickland Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Existing Occupancy:Fire Station Reviewing Authorities:NFPA 13 & Local Fire Marshal SYSTEM DESIGN Code:NFPA 13 Hazard:Light System Type:WET Area of Sprinkler Oper. 964 sq ftl Sprinkler or Nozzle Density (gpm /sq ft) 0.100 I Make: TYCO Area per Sprinkler 175.0 sq ftl Model: TY -FRB Hose Allowance Inside 100 gpm I K- Factor: 5.60 Hose Allowance Outside 0 gpm I Temperature Rating: 155 CALCULATION SUMMARY 11 Flowing Outlets gpm Required: 306.4 psi Required: 36.3 @ Source WATER SUPPLY Water Flow Test l Pump Data Date of Test 4/29/2009 I Rated Capacity 0 gpm 1 Static Pressure 56.0 psi 1 Rated Pressure 0.0 psi 1 Residual Pres 40.0 psi 1 Elevation 0 At a Flow of 1060 gpm 1 Make: Elevation 0" 1 Model: Location: Fire Hydrant South Of The Statio Source of Information: Zephyrhills Fire Department SYSTEM VOLUME 157 Gallons Notes: Dorm / Office Lower Area Jr NIES isk ej ' 29775 BANHEAD RD. DADE CITY, FL 33523 Fire Station #1 Drawing Date:5 /29/09 5/29/09 13:21 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 2 206 18.8 psi 1 Pipe 4" 10x21 18' 120 4.260 206 0.2 1 4" Grvd Shotgun Valve "90" 21' 120 4.026 206 0.3 1 4" Grvd Butterfly Valve "BFV" 14' 120 4.026 206 0.2 Elevation Change 21'0" 9.1 Fixed Flow Flow Loss 100 gpm Hydr Ref R1 Required at Base Of Riser 306 28.5 psi 1 Pipe 4" 10x21 2' 120 4.260 306 0.0 1 4" "GF" Adapter 0' 120 4.026 306 0.0 1 6" Grvd 90 Ell 14' 120 6.065 306 0.1 1 Pipe 6" 10x21 3' 120 6.357 306 0.0 1 6" Grvd 90 Ell 14' 120 6.065 306 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 306 0.0 1 6" MJ 90 Ell 14' 120 6.065 306 0.1 1 Pipe 6" DIx18 America DI 350 75' 140 6.338 306 0.2 1 6" MJ 45 Ell 7' 120 6.065 306 0.0 1 Pipe 6" DIx18 Cl 350 50' 140 6.338 306 0.1 1 6" MJ 45 Ell 7' 120 6.065 306 0.0 1 Pipe 6" DIx18 America DI 350 10' 140 6.338 306 0.0 1 6" MJ 90 Ell 14' 120 6.065 306 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 306 0.0 1 6" Flngd 90 Ell 14' 120 6.065 306 0.1 1 6" Flngd Gate Valve Kennedy "4068A" 3' 120 6.065 306 0.0 1 6" Flngd Back Flow Valve Ames "3000 CHART LOSS 306 6.8 1 6" Flngd Gate Valve Kennedy "4068A" 3' 120 6.065 306 0.0 1 6" Flngd 90 Ell 14' 120 6.065 306 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 306 0.0 1 6" MJ 90 Ell 14' 120 6.065 306 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 306 0.0 1 6" MJ 90 Ell 14' 120 6.065 306 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 306 0.0 1 12" MJ Tee 60' 120 11.938 306 0.0 1 Pipe 12" DIx18 01 350 150' 140 12.578 306 0.0 Hydr Ref R2 Required at Source 306 36.3 psi Water Source 56.0 psi static, 40.0 psi residual @ 1060 gpm 306 gpm 54.4 psi SAFETY PRESSURE 18.1 psi Available Pressure of 54.4 psi Exceeds Required Pressure of 36.3 psi This is a safety margin of 18.1 psi or 33 % of Supply Maximum Water Velocity is 20.0 fps Fire Station #1 Drawing Date:5 /29/09 5/29/09 13:21 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee ✓ Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. K FACTOR Flow factor for open head or path where Flow (gpm) = K x - \/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf /ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q /C) ^1.85 / ID ^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q ^2 /ID ^4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Fire Station #1 Drawing Date:5 /29/09 5/29/09 13:21 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K- FACTOR FLOW FLOW DENSITY (FT) (GPM /(PSI^)) (PSI) (GPM) (GPM) (GPM /SQ.FT) 201 9.42 11.2 201S 8.00 5.60 11.1 18.6 17.5 0.11 202 9.42 12.2 202S 8.00 5.60 12.1 19.5 14.8 0.14 203 9.42 13.6 203S 8.00 5.60 13.3 20.5 15.5 0.13 204 9.42 15.8 204S 8.00 5.60 15.4 22.0 14.8 0.18 205 9.42 7.6 2055 8.00 5.60 8.0 15.8 15.8 0.10 206 9.42 7.6 206S 8.00 5.60 7.9 15.8 14.8 0.16 207 9.42 9.4 207S 8.00 5.60 9.7 17.4 14.8 0.13 208 9.42 10.2 208S 8.00 5.60 10.4 18.1 14.8 0.18 209 9.42 10.0 2095 8.00 5.60 10.2 17.9 15.5 0.12 210 9.42 13.4 210S 8.00 5.60 13.2 20.3 17.4 0.12 211 9.42 13.2 211S 8.00 5.60 13.4 20.5 14.8 0.15 220 9.42 19.1 221 9.42 14.8 222 9.42 13.3 223 9.42 15.1 224 9.42 14.6 225 9.42 10.6 226 9.42 10.4 227 9.42 10.0 228 9.42 9.9 229 9.42 8.3 Al 9.42 21.0 A2 9.42 21.0 A3 17.83 18.0 A4 17.83 18.1 W 17.83 18.8 Max velocity of 20.03 occurs in the pipe from 224 TO 223 Nodes with "S" indicate a node at the top of a sprig or bottom of drop pendent. The node without an "S" is on the branch. Fire Station #1 Drawing Date:5 /29/09 5/29/09 13:21 Tyco Fire Products Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 206 TO W (PRIMARY PATH) 15.77 1.049 1E 1.42 7.9 7.9 K = 5.60 206S 0=120 2.00 -0.6 0.0 15.77 0.084 3.42 0.3 7.9 Vel = 5.91 1.049 1T 3.11 7.6 7.6 EqK = 5.72 206 C =120 5.00 0.0 0.0 15.77 0.084 8.11 0.7 7.6 Vel = 5.91 15.80 1.049 5.36 8.3 8.3 229 0 =120 0.00 0.0 0.0 See PATH 2 31.57 0.303 5.36 1.6 8.3 Vel = 11.83 1.610 2.36 9.9 9.9 228 0=120 0.00 0.0 0.0 31.57 0.038 2.36 0.1 9.9 Vel = 5.02 17.42 1.610 4.29 10.0 10.0 227 C =120 0.00 0.0 0.0 See PATH 3 48.99 0.085 4.29 0.4 10.0 Vel = 7.80 18.10 1.610 1.67 10.4 10.4 226 C =120 0.00 0.0 0.0 See PATH 5 67.09 0.152 1.67 0.3 10.4 Vel = 10.68 17.92 1.610 12.04 10.6 10.6 225 C =120 0.00 0.0 0.0 See PATH 4 85.01 0.235 12.04 2.8 10.6 Vel = 13.53 20.34 1.610 3.36 13.4 13.4 EqK = 5.55 210 0=120 0.00 0.0 0.0 105.35 0.349 3.36 1.2 13.4 Vel = 16.76 20.50 1.610 0.99 14.6 14.6 224 C =120 0.00 0.0 0.0 See PATH 7 125.85 0.485 0.99 0.5 14.6 Vel = 20.03 2.067 1T 31.00 15.1 15.1 223 0=120 10.00 0.0 0.0 125.85 0.144 41.00 5.9 15.1 Vel = 12.15 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Fire Station #1 Drawing Date:5 /29/09 5/29/09 13:21 Tyco Fire Products Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 206 TO W (PRIMARY PATH) 80.53 4.260 2E 32.91 21.0 21.0 A2 C =120 26.33 -3.6 0.0 See PATH 6 206.37 0.011 59.24 0.6 21.0 Vel = 4.69 4.260 9.67 18.0 18.0 A3 C =120 0.00 0.0 0.0 206.37 0.011 9.67 0.1 18.0 Vel = 4.69 4.260 lE 53.18 18.1 18.1 A4 C =120 13.17 0.0 0.0 206.37 0.011 66.35 0.7 18.1 Vel = 4.69 W 206.37 18.8 K = 47.64 20.34 1.049 1T 1.42 13.2 13.2 K = 5.60 210S 0=120 5.00 -0.6 0.0 20.34 0.134 6.42 0.9 13.2 Vel = 7.62 210 20.34 13.4 K = 5.55 PATH 2 FROM HYDRAULIC REFERENCE 205 TO 229 15.80 1.049 1E 1.42 8.0 8.0 K = 5.60 205S 0=120 2.00 -0.6 0.0 15.80 0.084 3.42 0.3 8.0 Vel = 5.92 1.049 1T 2.69 7.6 7.6 EqK = 5.72 205 0=120 5.00 0.0 0.0 15.80 0.084 7.69 0.6 7.6 Vel = 5.92 229 15.80 8.3 K = 5.49 PATH 3 FROM HYDRAULIC REFERENCE 207 TO 227 17.42 1.049 1E 1.42 9.7 9.7 K = 5.60 207S 0=120 2.00 -0.6 0.0 17.42 0.101 3.42 0.3 9.7 Vel = 6.53 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) • Fire Station #1 Drawing Date:5 /29/09 5/29/09 13:21 Tyco Fire Products Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 3 FROM HYDRAULIC REFERENCE 207 TO 227 CONTINUED 1.049 1T 0.82 9.4 9.4 EqK = 5.68 207 0=120 5.00 0.0 0.0 17.42 0.101 5.82 0.6 9.4 Vel = 6.53 227 17 :42 10.0 K = 5.51 PATH 4 FROM HYDRAULIC REFERENCE 209 TO 225 17.92 1.049 1E 1.42 10.2 10.2 K = 5.60 209S 0=120 2.00 -0.6 0.0 17.92 0.106 3.42 0.4 10.2 Vel = 6.72 1.049 1T 0.82 10.0 10.0 EqK = 5.67 209 0=120 5.00 0.0 0.0 17.92 0.106 5.82 0.6 10.0 Vel = 6.72 225 17.92 10.6 K = 5.50 PATH 5 FROM HYDRAULIC REFERENCE 208 TO 226 18.10 1.049 1E 1.42 10.4 10.4 K = 5.60 208S 0=120 2.00 -0.6 0.0 18.10 0.108 3.42 0.4 10.4 Vel = 6.79 1.610 1T 3.11 10.2 10.2 EqK = 5.67 208 0=120 8.00 0.0 0.0 18.10 0.013 11.11 0.1 10.2 Vel = 2.88 226 18.10 10.4 K = 5.63 PATH 6 FROM HYDRAULIC REFERENCE 201 TO A2 18.63 1.049 1T 1.42 11.1 11.1 K = 5.60 201S 0=120 5.00 -0.6 0.0 18.63 0.114 6.42 0.7 11.1 Vel = 6.99 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Fire Station #1 Drawing Date:5 /29/09 5/29/09 13:21 Tyco Fire Products Page 8 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 6 FROM HYDRAULIC REFERENCE 201 TO A2 CONTINUED 1.049 9.22 11.2 11.2 EqK = 5.57 201 0=120 0.00 0.0 0.0 18.63 0.114 9.22 1.1 11.2 Vel = 6.99 19.45 1.049 2.35 12.2 12.2 EqK = 5.56 202 0=120 0.00 0.0 0.0 38.08 0.428 2.35 1.0 12.2 Vel = 14.28 1.380 3.12 13.3 13.3 222 0=120 0.00 0.0 0.0 38.08 0.113 3.12 0.4 13.3 Vel = 8.25 20.46 1.380 4.88 13.6 13.6 EqK = 5.55 203 0=120 0.00 0.0 0.0 58.54 0.250 4.88 1.2 13.6 Vel = 12.68 1.610 8.26 14.8 14.8 221 C =120 0.00 0.0 0.0 58.54 0.118 8.26 1.0 14.8 Vel = 9.32 21.99 1.610 15.74 15.8 15.8 EqK = 5.53 204 0=120 0.00 0.0 0.0 80.53 0.213 15.74 3.3 15.8 Vel = 12.82 2.067 1T 19.00 19.1 19.1 220 0=120 10.00 0.0 0.0 80.53 0.063 29.00 1.8 19.1 Vel = 7.77 4.260 12.44 21.0 21.0 Al C =120 0.00 0.0 0.0 80.53 0.002 12.44 0.0 21.0 Vel = 1.83 A2 80.53 21.0 K = 17.58 19.45 1.049 1T 1.42 12.1 12.1 K = 5.60 202S 0=120 5.00 -0.6 0.0 19.45 0.124 6.42 0.8 12.1 Vel = 7.29 202 19.45 12.2 K = 5.56 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Fire Station #1 Drawing Date:5 /29/09 5/29/09 13:21 Tyco Fire Products Page 9 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn 20.46 1.049 1T 1.42 13.3 13.3 K = 5.60 203S 0=120 5.00 -0.6 0.0 20.46 0.136 6.42 0.9 13.3 Vel = 7.67 203 20.46 13.6 K = 5.55 21.99 1.049 1T 1.42 15.4 15.4 K = 5.60 204S C =120 5.00 -0.6 0.0 21.99 0.155 6.42 1.0 15.4 Vel = 8.24 204 21.99 15.8 K = 5.53 PATH 7 FROM HYDRAULIC REFERENCE 211 TO 224 20.50 1.049 1E 1.42 13.4 13.4 K = 5.60 211S 0=120 2.00 -0.6 0.0 20.50 0.136 3.42 0.5 13.4 Vel = 7.68 1.049 1T 5.00 13.2 13.2 EqK = 5.63 211 0=120 5.00 0.0 0.0 20.50 0.136 10.00 1.4 13.2 Vel = 7.68 224 20.50 14.6 K = 5.36 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) 0 0 LO I ■ 0 Lo i I I I I i E E ' N a Q LI lT lm co 3� ; 0 0 a a� O C I I CO I E E ._ ._ rn a Q ■ � E c) (0 (0 — M O O N a) o . ... O- I C 3 g- a� _ O a� L 0 °. 6 I j LL - a Qjll1 m m' °-= E E 3 w N N N 1 Q' d (A fn (n 2 l • o a) I o co '( .N Q H a0rn - 000 O i o o v o ° S i 1 I 1 c o m o : � c , O N a N= i 0 N o d O t9 r N (0 p I ■ 5. CnCC ll0J f O ■ O \ , N CV M co • I co O - .O co N p N ; *k cK LL C C O L' 4 Q .( • a 0 (x+00 T O o r. S] N O Q E N O rn O O - )LLcoNCC • p a ` O O o ( o acn— Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:53 HYDRAULIC DESIGN INFORMATION SHEET Job Name: Fire Station #1 Location: 6907 Dairy Road Zephyrhills, Florida 33542 Drawing Date: 5/29/09 Remote Area Number: 3 Contractor: SimplexGrinnell LP Telephone:813- 626 -5482 4701 Oak Fair Blvd. Tampa, Florida 33610 Designer: Al Strickland Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Existing Occupancy:Fire Station Reviewing Authorities:NFPA 13 & Local Fire Marshal SYSTEM DESIGN Code:NFPA 13 Hazard:LIGHT System Type:WET Area of Sprinkler Oper. 1500 sq ftI Sprinkler or Nozzle Density (gpm /sq ft) 0.100 I Make: TYCO Area per Sprinkler 120.0 sq ftl Model: TY -FRB Hose Allowance Inside 0 gpm I K- Factor: 5.60 Hose Allowance Outside 0 gpm 1 Temperature Rating: 200 CALCULATION SUMMARY 19 Flowing Outlets gpm Required: 467.0 psi Required: 41.9 @ Source WATER SUPPLY Water Flow Test 1 Pump Data Date of Test 4/29/2009 1 Rated Capacity 0 gpm 1 Static Pressure 56.0 psi 1 Rated Pressure 0.0 psi Residual Pres 40.0 psi 1 Elevation 0 At a Flow of 1060 gpm I Make: Elevation 0" 1 Model: Location: Fire Hydrant South Of The Statio Source of Information: Zephyrhills Fire Department SYSTEM VOLUME 157 Gallons Notes: Apparatus Bay Attic -ME sS t P,T1 1:'1791 I t ,A % � / , /, raga, ,' 29775 EAYHEAD RD. DADE CF d "Y, FL 33593 Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:53 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 3 367 21.4 psi 1 Pipe 4" 10x21 18' 120 4.260 367 0.6 1 4" Grvd Shotgun Valve "90" 21' 120 4.026 367 0.9 1 4" Grvd Butterfly Valve "BFV" 14' 120 4.026 367 0.6 Elevation Change 21'0" 9.1 Fixed Flow Flow Loss 100 gpm Hydr Ref R1 Required at Base Of Riser 467 32.5 psi 1 Pipe 4" 10x21 2' 120 4.260 467 0.1 1 4" "GF" Adapter 0' 120 4.026 467 0.0 1 6" Grvd 90 Ell 14' 120 6.065 467 0.1 1 Pipe 6" 10x21 3' 120 6.357 467 0.0 1 6" Grvd 90 Ell 14' 120 6.065 467 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 467 0.0 1 6" MJ 90 Ell 14' 120 6.065 467 0.1 1 Pipe 6" DIx18 America DI 350 75' 140 6.338 467 0.4 1 6" MJ 45 E11 7' 120 6.065 467 0.1 1 Pipe 6" DIx18 Cl 350 50' 140 6.338 467 0.3 1 6" MJ 45 Ell 7' 120 6.065 467 0.1 1 Pipe 6" DIx18 America DI 350 10' 140 6.338 467 0.1 1 6" MJ 90 Ell 14' 120 6.065 467 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 467 0.0 1 6" Flngd 90 Ell 14' 120 6.065 467 0.1 1 6" Flngd Gate Valve Kennedy "4068A" 3' 120 6.065 467 0.0 1 6" Flngd Back Flow Valve Ames "3000 CHART LOSS 467 7.2 1 6" Flngd Gate Valve Kennedy "4068A" 3' 120 6.065 467 0.0 1 6" Flngd 90 Ell 14' 120 6.065 467 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 467 0.0 1 6" MJ 90 Ell 14' 120 6.065 467 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 467 0.0 1 6" MJ 90 Ell 14' 120 6.065 467 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 467 0.0 1 12" MJ Tee 60' 120 11.938 467 0.0 1 Pipe 12" DIx18 Cl 350 150' 140 12.578 467 0.0 Hydr Ref R2 Required at Source 467 41.9 psi Water Source 56.0 psi static, 40.0 psi residual @ 1060 gpm 467 gpm 52.5 psi SAFETY PRESSURE 10.6 psi Available Pressure of 52.5 psi Exceeds Required Pressure of 41.9 psi This is a safety margin of 10.6 psi or 20 % of Supply Maximum Water Velocity is 14.9 fps Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:53 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee V Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. K FACTOR Flow factor for open head or path where Flow (gpm) = K x - \/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf /ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q /C) ^1.85 / ID ^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q ^2 /ID ^4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:53 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K- FACTOR FLOW FLOW DENSITY (FT) (GPM /(PSI ^)) (PSI) (GPM) (GPM) (GPM /SQ.FT) 301 17.83 9.5 301S 18.50 5.60 9.0 16.8 14.8 0.14 302 17.83 11.0 302S 18.50 5.60 10.4 18.1 14.8 0.15 303 17.83 11.3 3035 18.50 5.60 10.7 18.3 14.8 0.15 304 17.83 12.6 304S 18.50 5.60 12.0 19.4 14.8 0.16 305 17.83 10.2 305S 19.50 5.60 8.9 16.7 14.8 0.14 307 25.50 5.60 7.0 14.8 14.8 0.12 308 17.83 12.9 308S 19.50 5.60 11.4 18.9 14.8 0.16 309 25.50 5.60 7.6 15.4 14.8 0.13 310 17.83 14.5 310S 19.50 5.60 12.9 20.1 14.8 0.17 311 17.83 14.5 311S 19.50 5.60 12.9 20.1 14.8 0.17 312 17.83 15.5 312S 19.50 5.60 13.8 20.8 14.8 0.17 313 25.50 5.60 9.8 17.6 14.8 0.15 314 17.83 15.9 314S 19.50 5.60 14.3 21.1 14.8 0.18 315 17.83 16.5 315S 19.50 5.60 14.8 21.5 14.8 0.18 316 25.50 5.60 11.2 18.7 14.8 0.16 317 17.83 18.2 317S 19.50 5.60 16.4 22.7 14.8 0.19 318 17.83 18.2 318S 19.50 5.60 16.4 22.7 14.8 0.19 319 25.50 5.60 12.4 19.7 14.8 0.16 320 17.83 19.3 320S 19.50 5.60 17.4 23.4 14.8 0.19 434 17.83 18.9 435 17.83 16.8 436 17.83 12.1 437 25.50 15.0 A4 17.83 19.6 A5 17.83 19.6 A6 17.83 19.6 A7 17.83 19.8 W 17.83 21.4 Max velocity of 14.91 occurs in the pipe from 314 TO 317 Nodes with "S" indicate a node at the top of a sprig or bottom of drop pendent. The node without an "S" is on the branch. Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:53 Tyco Fire Products Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 301 TO W (PRIMARY PATH) 16.80 1.049 1E 0.67 9.0 9.0 K = 5.60 301S 0=120 2.00 0.3 0.0 16.80 0.094 2.67 0.3 9.0 Vel = 6.30 1.049 1E 5.08 9.5 9.5 EqK = 5.44 301 0=120 2.00 0.0 0.0 16.80 0.094 7.08 0.7 9.5 Vel = 6.30 16.68 1.049 8.00 10.2 10.2 EqK = 5.22 305 0=120 0.00 0.0 0.0 33.48 0.338 8.00 2.7 10.2 Vel = 12.55 18.91 1.380 8.00 12.9 12.9 EqK = 5.26 308 0=120 0.00 0.0 0.0 52.39 0.203 8.00 1.6 12.9 Vel = 11.35 20.14 1.610 8.00 14.5 14.5 EqK = 5.28 311 0=120 0.00 0.0 0.0 72.53 0.175 8.00 1.4 14.5 Vel = 11.54 21.14 1.610 8.00 15.9 15.9 EqK = 5.30 314 0=120 0.00 0.0 0.0 93.68 0.281 8.00 2.2 15.9 Vel = 14.91 22.66 2.067 1T 2.82 18.2 18.2 EqK = 5.31 317 0=120 10.00 0.0 0.0 116.34 0.124 12.82 1.6 18.2 Vel = 11.23 250.65 4.260 1E 40.51 19.8 19.8 A7 C =120 13.17 0.0 0.0 See PATH 2 366.98 0.031 53.68 1.7 19.8 Vel = 8.34 W 366.98 21.4 K = 79.27 • UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:53 Tyco Fire Products Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn 16.68 1.049 1T 1.67 8.9 8.9 K = 5.60 3055 0=120 5.00 0.7 0.0 16.68 0.093 6.67 0.6 8.9 Vel = 6.25 305 16.68 10.2 K = 5.22 18.91 1.049 1T 1.67 11.4 11.4 K = 5.60 308S 0=120 5.00 0.7 0.0 18.91 0.117 6.67 0.8 11.4 Vel = 7.09 308 18.91 12.9 K = 5.26 20.14 1.049 1T 1.67 12.9 12.9 K = 5.60 311S 0=120 5.00 0.7 0.0 20.14 0.132 6.67 0.9 12.9 Vel = 7.55 311 20.14 14.5 K = 5.28 21.14 1.049 1T 1.67 14.3 14.3 K = 5.60 314S 0=120 5.00 0.7 0.0 21.14 0.144 6.67 1.0 14.3 Vel = 7.93 314 21.14 15.9 K = 5.30 22.66 1.049 1T 1.67 16.4 16.4 K = 5.60 317S 0=120 5.00 0.7 0.0 22.66 0.164 6.67 1.1 16.4 Vel = 8.49 317 22.66 18.2 K = 5.31 PATH 2 FROM HYDRAULIC REFERENCE 307 TO A7 14.82 1.049 8.00 7.0 7.0 K = 5.60 307 C =120 0.00 0.0 0.0 14.82 0.075 8.00 0.6 7.0 Vel = 5.55 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:53 Tyco Fire Products Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 2 FROM HYDRAULIC REFERENCE 307 TO A7 CONTINUED 15.44 1.049 8.00 7.6 7.6 K = 5.60 309 C =120 0.00 0.0 0.0 30.25 0.280 8.00 2.2 7.6 Vel = 11.34 17.56 1.380 8.00 9.8 9.8 K = 5.60 313 C =120 0.00 0.0 0.0 47.81 0.172 8.00 1.4 9.8 Vel = 10.36 18.75 1.610 8.00 11.2 11.2 K = 5.60 316 C =120 0.00 0.0 0.0 66.56 0.149 8.00 1.2 11.2 Vel = 10.59 19.72 1.610 1T 2.82 12.4 12.4 K = 5.60 319 0=120 8.00 0.0 0.0 86.29 0.241 10.82 2.6 12.4 Vel = 13.73 2.067 1T 7.67 15.0 15.0 437 C =120 10.00 3.3 0.0 86.29 0.072 17.67 1.3 15.0 Vel = 8.33 164.36 4.260 11.45 19.6 19.6 A6 C =120 0.00 0.0 0.0 See PATH 3 250.65 0.015 11.45 0.2 19.6 Vel = 5.70 A7 250.65 19.8 K = 56.35 PATH 3 FROM HYDRAULIC REFERENCE 302 TO A6 18.08 1.049 1E 0.67 10.4 10.4 K = 5.60 302S C =120 2.00 0.3 0.0 18.08 0.108 2.67 0.3 10.4 Vel = 6.78 1.049 1T 5.42 11.0 11.0 EqK = 5.45 302 C =120 5.00 0.0 0.0 18.08 0.108 10.42 1.1 11.0 Vel = 6.78 18.32 1.049 11.83 12.1 12.1 436 C =120 0.00 0.0 0.0 See PATH 4 36.39 0.394 11.83 4.7 12.1 Vel = 13.64 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:53 Tyco Fire Products Page 8 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 3 FROM HYDRAULIC REFERENCE 302 TO A6 CONTINUED 1.380 20.00 16.8 16.8 435 C =120 0.00 0.0 0.0 36.39 0.104 20.00 2.1 16.8 Vel = 7.88 1.610 1T 7.32 18.9 18.9 434 0 =120 8.00 0.0 0.0 36.39 0.049 15.32 0.7 18.9 Vel = 5.79 127.97 4.260 1.21 19.6 19.6 A5 C =120 0.00 0.0 0.0 See PATH 5 164.36 0.007 1.21 0.0 19.6 Vel = 3.74 A6 164.36 19.6 K = 37.12 PATH 4 FROM HYDRAULIC REFERENCE 303 TO 436 18.32 1.049 1E 0.67 10.7 10.7 K = 5.60 303S 0=120 2.00 0.3 0.0 18.32 0.111 2.67 0.3 10.7 Vel = 6.87 1.049 1T 2.58 11.3 11.3 EqK = 5.45 303 C =120 5.00 0.0 0.0 18.32 0.111 7.58 0.8 11.3 Vel = 6.87 436 18.32 12.1 K = 5.26 PATH 5 FROM HYDRAULIC REFERENCE 304 TO A5 19.42 1.049 1E 0.67 12.0 12.0 K = 5.60 304S 0=120 2.00 0.3 0.0 19.42 0.123 2.67 0.3 12.0 Vel = 7.28 1.049 lE 13.25 12.6 12.6 EqK = 5.46 304 0=120 2.00 0.0 0.0 19.42 0.123 15.25 1.9 12.6 Vel = 7.28 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:53 Tyco Fire Products Page 9 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 5 FROM HYDRAULIC REFERENCE 304 TO A5 CONTINUED 20.13 1.380 8.00 14.5 14.5 EqK = 5.28 310 0=120 0.00 0.0 0.0 39.56 0.121 8.00 1.0 14.5 Vel = 8.57 20.83 1.610 8.00 15.5 15.5 EqK = 5.29 312 0=120 0.00 0.0 0.0 60.39 0.125 8.00 1.0 15.5 Vel = 9.61 21.53 1.610 8.00 16.5 16.5 EqK = 5.30 315 0=120 0.00 0.0 0.0 81.91 0.219 8.00 1.8 16.5 Vel = 13.04 22.70 2.067 1T 2.82 18.2 18.2 EqK = 5.31 318 0=120 10.00 0.0 0.0 104.61 0.102 12.82 1.3 18.2 Vel = 10.10 23.36 4.260 9.67 19.6 19.6 A4 C =120 0.00 0.0 0.0 See PATH 6 127.97 0.004 9.67 0.0 19.6 Vel = 2.91 A5 127.97 19.6 K = 28.91 20.13 1.049 1T 1.67 12.9 12.9 K = 5.60 310S 0=120 5.00 0.7 0.0 20.13 0.132 6.67 0.9 12.9 Vel = 7.55 310 20.13 14.5 K = 5.28 20.83 1.049 1T 1.67 13.8 13.8 K = 5.60 312S 0=120 5.00 0.7 0.0 20.83 0.140 6.67 0.9 13.8 Vel = 7.81 312 20.83 15.5 K = 5.29 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) • Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:53 Tyco Fire Products Page 10 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn 21.53 1.049 1T 1.67 14.8 14.8 K = 5.60 315S C =120 5.00 0.7 0.0 21.53 0.149 6.67 1.0 14.8 Vel = 8.07 315 21.53 16.5 K = 5.30 22.70 1.049 1T 1.67 16.4 16.4 K = 5.60 318S C =120 5.00 0.7 0.0 22.70 0.164 6.67 1.1 16.4 Vel = 8.51 318 22.70 18.2 K = 5.31 PATH 6 FROM HYDRAULIC REFERENCE 320 TO A4 23.36 1.049 1T 1.67 17.4 17.4 K = 5.60 320S C =120 5.00 0.7 0.0 23.36 0.173 6.67 1.2 17.4 Vel = 8.76 1.610 1T 5.18 19.3 19.3 EqK = 5.32 320 C =120 8.00 0.0 0.0 23.36 0.022 13.18 0.3 19.3 Vel = 3.72 A4 23.36 19.6 K = 5.28 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) • O O Lo • 1 i O Lo v i iitiiiiiiiio d Q d V Cn m I 6 9 0 0 G 1 O Q 6 I r o v O ( = 2 c0 1 rn Q. v�� O M I O oo� U. -4:; aim = a a ' ) 1 E w a0 U) -- a) L- > , >, (a a 1 4 CI- (1)(.0 U)1 ■ 0 0 a) M Th d H I l l 1 0 0 0 0 1p 'cp O Qi I O C �v�i o� I i O in = a) O - d N u) L N >+ I 0 0 _ O I III" I (3 N a) d,Ua .. L.L ! o o cy v ! M - O m0M . ( Q ■ ■ �'■■■■.■■■■■■.■. II .■�■ o0 ■ 11111 •11I1iI • I O= c) O O O O V co N N- CL CO — Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:55 HYDRAULIC DESIGN INFORMATION SHEET Job Name: Fire Station #1 Location: 6907 Dairy Road Zephyrhills, Florida 33542 Drawing Date: 5/29/09 Remote Area Number: 4 Contractor: SimplexGrinnell LP Telephone:813- 626 -5482 4701 Oak Fair Blvd. Tampa, Florida 33610 Designer: Al Strickland Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Existing Occupancy:Fire Station Reviewing Authorities:NFPA 13 & Local Fire Marshal SYSTEM DESIGN Code:NFPA 13 Hazard:LIGHT System Type:WET Area of Sprinkler Oper. 1500 sq ftl Sprinkler or Nozzle Density (gpm /sq ft) 0.100 1 Make: TYCO Area per Sprinkler 120.0 sq ftl Model: TY -FRB Hose Allowance Inside 0 gpm 1 K- Factor: 5.60 Hose Allowance Outside 0 gpm 1 Temperature Rating: 200 CALCULATION SUMMARY 20 Flowing Outlets gpm Required: 448.9 psi Required: 41.4 @ Source WATER SUPPLY Water Flow Test 1 Pump Data Date of Test 4/29/2009 1 Rated Capacity 0 gpm I Static Pressure 56.0 psi 1 Rated Pressure 0.0 psi Residual Pres 40.0 psi 1 Elevation 0 At a Flow of 1060 gpm 1 Make: Elevation 0" 1 Model: Location: Fire Hydrant South Of The Statio Source of Information: Zephyrhills Fire Department SYSTEM VOLUME 157 Gallons Notes: Dorm / Office Attic J , i , D ARE C Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:55 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 4 349 21.3 psi 1 Pipe 4" 10x21 18' 120 4.260 349 0.5 1 4" Grvd Shotgun Valve "90" 21' 120 4.026 349 0.8 1 4" Grvd Butterfly Valve "BFV" 14' 120 4.026 349 0.5 Elevation Change 21'0" 9.1 Fixed Flow Flow Loss 100 gpm Hydr Ref R1 Required at Base Of Riser 449 32.2 psi 1 Pipe 4" 10x21 2' 120 4.260 449 0.1 1 4" "GF" Adapter 0' 120 4.026 449 0.0 1 6" Grvd 90 Ell 14' 120 6.065 449 0.1 1 Pipe 6" 10x21 3' 120 6.357 449 0.0 1 6" Grvd 90 Ell 14' 120 6.065 449 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 449 0.0 1 6" MJ 90 Ell 14' 120 6.065 449 0.1 1 Pipe 6" DIx18 America DI 350 75' 140 6.338 449 0.4 1 6" MJ 45 Ell 7' 120 6.065 449 0.1 1 Pipe 6" DIx18 Cl 350 50' 140 6.338 449 0.2 1 6" MJ 45 Ell 7' 120 6.065 449 0.1 1 Pipe 6" DIx18 America DI 350 10' 140 6.338 449 0.0 1 6" MJ 90 Ell 14' 120 6.065 449 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 449 0.0 1 6" Flngd 90 Ell 14' 120 6.065 449 0.1 1 6" Flngd Gate Valve Kennedy "4068A" 3' 120 6.065 449 0.0 1 6" Flngd Back Flow Valve Ames "3000 CHART LOSS 449 7.1 1 6" Flngd Gate Valve Kennedy "4068A" 3' 120 6.065 449 0.0 1 6" Flngd 90 Ell 14' 120 6.065 449 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 449 0.0 1 6" MJ 90 Ell 14' 120 6.065 449 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 449 0.0 1 6" MJ 90 Ell 14' 120 6.065 449 0.1 1 Pipe 6" DIx18 America DI 350 5' 140 6.338 449 0.0 1 12" MJ Tee 60' 120 11.938 449 0.0 1 Pipe 12" DIx18 C1 350 150' 140 12.578 449 0.0 Hydr Ref R2 Required at Source 449 41.4 psi Water Source 56.0 psi static, 40.0 psi residual @ 1060 gpm 449 gpm 52.7 psi SAFETY PRESSURE 11.4 psi Available Pressure of 52.7 psi Exceeds Required Pressure of 41.4 psi • This is a safety margin of 11.4 psi or 22 % of Supply Maximum Water Velocity is 17.2 fps Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:55 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee ✓ Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. _ K FACTOR Flow factor for open head or path where Flow (gpm) = K x - \/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf /ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q /C) ^1.85 / ID ^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q ^2 /ID ^4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:55 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K- FACTOR FLOW FLOW DENSITY (FT) (GPM /(PSI ^ -)) (PSI) (GPM) (GPM) (GPM /SQ.FT) 401 9.42 5.60 7.1 14.9 14.8 0.12 402 9.42 5.60 7.0 14.8 14.8 0.12 403 9.42 5.60 7.9 15.7 14.8 0.13 404 9.42 5.60 7.7 15.6 14.8 0.13 405 9.42 8.5 4055 10.33 5.60 7.6 15.5 14.8 0.13 406 9.42 8.4 4065 10.33 5.60 7.5 15.3 14.8 0.13 407 9.42 9.4 407S 12.50 5.60 7.7 15.5 14.8 0.13 408 9.42 9,5 4085 12.50 5.60 7.8 15.6 14.8 0.13 409 9.42 10.7 409S 10.33 5.60 9.7 17.5 14.8 0.15 410 9.42 10.9 410S 10.33 5.60 9.8 17.6 14.8 0.15 411 9.42 11.3 411S 14.67 5.60 8.2 16.0 14.8 0.13 412 9.42 12.1 412S 10.33 5.60 11.0 18.6 14.8 0.16 413 9.42 12.3 413S 10.33 5.60 11.2 18.7 14.8 0.16 414 9.42 12.9 414S 14.67 5.60 9.6 17.3 14.8 0.14 415 9.42 13.5 415S 10.33 5.60 12.3 19.7 14.8 0.16 416 9.42 13.3 416S 10.33 5.60 12.2 19.6 14.8 0.16 417 9.42 15.1 417S 14.67 5.60 11.6 19.1 14.8 0.16 418 9.42 15.3 418S 10.33 5.60 14.0 21.0 14.8 0.17 419 9.42 15.5 419S 10.33 5.60 14.2 21.1 14.8 0.18 420 9.42 16.1 420S 14.67 5.60 12.5 19.8 14.8 0.17 430 9.42 18.2 431 9.42 10.2 432 9.42 7.7 433 9.42 18.4 Al 9.42 21.3 A2 9.42 21.4 A3 9.42 21.5 A4 17.83 19.2 A5 17.83 19.5 A6 17.83 19.5 A7 17.83 19.8 W 17.83 21.3 Max velocity of 17.21 occurs in the pipe from 419 TO 433 Nodes with "S" indicate a node at the top of a sprig or bottom of drop pendent. The node without an "S" is on the branch. Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:55 Tyco Fire Products Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 402 TO W (PRIMARY PATH) 14.82 1.049 1T 4.44 7.0 7.0 K = 5.60 402 0=120 5.00 0.0 0.0 14.82 0.075 9.44 0.7 7.0 Vel = 5.55 14.88 1.049 9.29 7.7 7.7 432 C =120 0.00 0.0 0.0 See PATH 2 29.70 0.270 9.29 2.5 7.7 Vel = 11.13 31.13 1.610 8.71 10.2 10.2 431 C =120 0.00 0.0 0.0 See PATH 5 AND 6 60.83 0.126 8.71 1.1. 10.2 Vel = 9.68 16.00 1.610 8.00 11.3 11.3 EqK = 4.75 411 0=120 0.00 0.0 0.0 76.83 0.195 8.00 1.6 11.3 Vel = 12.23 17.33 1.610 8.00 12.9 12.9 EqK = 4.83 414 0=120 0.00 0.0 0.0 94.15 0.284 8.00 2.3 12.9 Vel = 14.98 19.11 2.067 8.00 15.1 15.1 EqK = 4.91 417 0=120 0.00 0.0 0.0 113.26 0.118 8.00 0.9 15.1 Vel = 10.94 19.80 2.067 1T 23.00 16.1 16.1 EqK = 4.94 420 0=120 10.00 0.0 0.0 133.07 0.159 33.00 5.3 16.1 Vel = 12.85 107.65 4.260 12.95 21.4 21.4 A2 C =120 0.00 0.0 0.0 See PATH 4 240.72 0.014 12.95 0.2 21.4 Vel = 5.47 108.14 4.260 2E 19.96 21.5 21.5 A3 C =120 26.33 -3.6 0.0 See PATH 3 348.86 0.028 46.29 1.3 21.5 Vel = 7.93 4.260 9.67 19.2 19.2 A4 C =120 0.00 0.0 0.0 348.86 0.028 9.67 0.3 19.2 Vel = 7.93 4.260 1.21 19.5 19.5 A5 C =120 0.00 0.0 0.0 348.86 0.028 1.21 0.0 19.5 Vel = 7.93 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:55 Tyco Fire Products Page 6 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 402 TO W (PRIMARY PATH) 4.260 11.45 19.5 19.5 A6 C =120 0.00 0.0 0.0 348.86 0.028 11.45 0.3 19.5 Vel = 7.93 4.260 1E 40.51 19.8 19.8 A7 C =120 13.17 0.0 0.0 348.86 0.028 53.68 1.5 19.8 Vel = 7.93 W 348.86 21.3 K = 75.57 16.00 1.049 1T 5.25 8.2 8.2 K = 5.60 411S C =120 5.00 2.3 0.0 16.00 0.086 10.25 0.9 8.2 Vel = 6.00 411 16.00 11.3 K = 4.75 17.33 1.049 1T 5.25 9.6 9.6 K = 5.60 414S C =120 5.00 2.3 0.0 17.33 0.100 10.25 1.0 9.6 Vel = 6.50 414 17.33 12.9 K = 4.83 19.11 1.049 1T 5.25 11.6 11.6 K = 5.60 417S C =120 5.00 2.3 0.0 19.11 0.120 10.25 1.2 11.6 Vel = 7.16 417 19.11 15.1 K = 4.91 19.80 1.049 1T 5.25 12.5 12.5 K = 5.60 420S C =120 5.00 2.3 0.0 19.80 0.128 10.25 1.3 12.5 Vel = 7.42 420 19.80 16.1 K = 4.94 PATH 2 FROM HYDRAULIC REFERENCE 401 TO 432 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:55 Tyco Fire Products Page 7 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 2 FROM HYDRAULIC REFERENCE 401 TO 432 CONTINUED 14.88 1.049 1T 3.56 7.1 7.1 K = 5.60 401 0=120 5.00 0.0 0.0 14.88 0.075 8.56 0.6 7.1 Vel = 5.58 432 14.88 7.7 K = 5.36 PATH 3 FROM HYDRAULIC REFERENCE 404 TO A3 15.58 1.049 15 7.39 7.7 7.7 K = 5.60 404 0=120 2.00 0.0 0.0 15.58 0.082 9.39 0.8 7.7 Vel = 5.84 15.47 1.049 8.00 8.5 8.5 EqK = 5.30 405 0=120 0.00 0.0 0.0 31.04 0.294 8.00 2.3 8.5 Vel = 11.64 17.58 1.380 8.01 10.9 10.9 EqK = 5.33 410 0=120 0.00 0.0 0.0 48.62 0.177 8.01 1.4 10.9 Vel = 10.53 18.73 1.610 7.99 12.3 12.3 EqK = 5.35 413 0=120 0.00 0.0 0.0 67.35 0.153 7.99 1.2 12.3 Vel = 10.72 19.68 1.610 8.00 13.5 13.5 EqK = 5.36 415 C =120 0.00 0.0 0.0 87.03 0.245 8.00 2.0 13.5 Vel = 13.85 21.11 1.610 8.00 15.5 15.5 EqK = 5.37 419 0=120 0.00 0.0 0.0 108.14 0.367 8.00 2.9 15.5 Vel = 17.21 2.067 1T 19.00 18.4 18.4 433 0=120 10.00 0.0 0.0 108.14 0.109 29.00 3.1 18.4 Vel = 10.44 A3 108.14 21.5 K = 23.30 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:55 Tyco Fire Products Page 8 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn 15.47 1.049 1T 0.92 7.6 7.6 K = 5.60 4055 0=120 5.00 0.4 0.0 15.47 0.081 5.92 0.5 7.6 Vel = 5.80 405 15.47 8.5 K = 5.30 17.58 1.049 1T 0.92 9.8 9.8 K = 5.60 410S 0 =120 5.00 0.4 0.0 17.58 0.102 5.92 0.6 9.8 Vel = 6.59 410 17.58 10.9 K = 5.33 18.73 1.049 1T 0.92 11.2 11.2 K = 5.60 413S 0=120 5.00 0.4 0.0 18.73 0.115 5.92 0.7 11.2 Vel = 7.02 413 18.73 12.3 K = 5.35 19.68 1.049 1T 0.92 12.3 12.3 K = 5.60 415S 0=120 5.00 0.4 0.0 19.68 0.126 5.92 0.7 12.3 Vel = 7.38 415 19.68 13.5 K = 5.36 21.11 1.049 1T 0.92 14.2 14.2 K = 5.60 419S 0=120 5.00 0.4 0.0 21.11 0.144 5.92 0.9 14.2 Vel = 7.91 419 21.11 15.5 K = 5.37 PATH 4 FROM HYDRAULIC REFERENCE 403 TO A2 15.71 1.049 6.00 7.9 7.9 K = 5.60 403 0=120 0.00 0.0 0.0 15.71 0.083 6.00 0.5 7.9 Vel = 5.89 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:55 Tyco Fire Products Page 9 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 4 FROM HYDRAULIC REFERENCE 403 TO A2 CONTINUED 15.33 1.049 8.00 8.4 8.4 EqK = 5.30 406 0=120 0.00 0.0 0.0 31.04 0.293 8.00 2.3 8.4 Vel = 11.64 17.46 1.380 8.00 10.7 10.7 EqK = 5.33 409 0=120 0.00 0.0 0.0 48.49 0.176 8.00 1.4 10.7 Vel = 10.50 18.61 1.610 8.00 12.1 12.1 EqK = 5.35 412 0=120 0.00 0.0 0.0 67.11 0.152 8.00 1.2 12.1 Vel = 10.68 19.56 1.610 8.00 13.3 13.3 EqK = 5.36 416 0=120 0.00 0.0 0.0 86.67 0.243 8.00 1.9 13.3 Vel = 13.79 20.99 1.610 8.00 15.3 15.3 EqK = 5.37 418 0=120 0.00 0.0 0.0 107.65 0.364 8.00 2.9 15.3 Vel = 17.13 2.067 1T 19.00 18.2 18.2 430 0=120 10.00 0.0 0.0 107.65 0.108 29.00 3.1 18.2 Vel = 10.39 4.260 12.44 21.3 21.3 Al C =120 0.00 0.0 0.0 107.65 0.003 12.44 0.0 21.3 Vel = 2.45 A2 107.65 21.4 K = 23.30 15.33 1.049 1T 0.92 7.5 7.5 K = 5.60 406S 0=120 5.00 0.4 0.0 15.33 0.080 5.92 0.5 7.5 Vel = 5.75 406 15.33 8.4 K = 5.30 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:55 Tyco Fire Products Page 10 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn 17.46 1.049 1T 0.92 9.7 9.7 K = 5.60 4095 0=120 5.00 0.4 0.0 17.46 0.101 5.92 0.6 9.7 Vel = 6.54 409 17.46 10.7 K = 5.33 18.61 1.049 1T 0.92 11.0 11.0 K = 5.60 412S 0=120 5.00 0.4 0.0 18.61 0.114 5.92 0.7 11.0 Vel = 6.98 412 18.61 12.1 K = 5.35 19.56 1.049 1T 0.92 12.2 12.2 K = 5.60 416S 0=120 5.00 0.4 0.0 19.56 0.125 5.92 0.7 12.2 Vel = 7.33 416 19.56 13.3 K = 5.36 20.99 1.049 1T 0.92 14.0 14.0 K = 5.60 418S 0=120 5.00 0.4 0.0 20.99 0.142 5.92 0.8 14.0 Vel = 7.87 418 20.99 15.3 K = 5.37 PATH 5 FROM HYDRAULIC REFERENCE 407 TO 431 15.53 1.049 lE 3.08 7.7 7.7 K = 5.60 407S 0=120 2.00 1.3 0.0 15.53 0.082 5.08 0.4 7.7 Vel = 5.82 1.049 1T 4.44 9.4 9.4 EqK = 5.05 407 0=120 5.00 0.0 0.0 15.53 0.082 9.44 0.8 9.4 Vel = 5.82 431 15.53 10.2 K = 4.86 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) Fire Station #1 Drawing Date:5 /29/09 5/29/09 11:55 Tyco Fire Products Page 11 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 6 FROM HYDRAULIC REFERENCE 408 TO 431 15.60 1.049 1E 3.08 7.8 7.8 K = 5.60 408S C =120 2.00 1.3 0.0 15.60 0.082 5.08 0.4 7.8 Vel = 5.85 1.049 1T 3.56 9.5 9.5 EqK = 5.06 408 C =120 5.00 0.0 0.0 15.60 0.082 8.56 0.7 9.5 Vel = 5.85 431 15.60 10.2 K = 4.88 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) 0 0 LO o 11 1111111111111111111111 v daQ c.)mrn c00 0 0 0 a ai v o ( m 2 E0 Q �W Q a) 0) n Q vrnrnvo a , -r 11111111 `Co) 3 e o o0 o O iri O 2 a) c) 1 3 E E w a� �maa o (.0 U) 4- CD >, >, a3 a) I 11 1 0 O _ _ L N o H- o_ O 0) M- C) O o 0 c0 O O L to r 5 0 cn IN a) cn Q c0 J L V) L N T d 2 i I M @ M N C L i- O Q 1 1 0 y6 0 i 0 O .0 a) a E 0 - -` o 0 a) —) Li.co 0 o O o 0 0 0 aJ to V co N r acn— SG 30x42V "71 b 0 y 7 L ` 1 M � J b c�i A ° _ � 3 g0 d D ���b_N% 0 C�D n � CD � CD II � �n I o� 0 T b N o� ^C r r 1�J ww �Jv O ti ° _ � 3 g0 d D x �D w A iv ny �a� c n y D 94 1 Y ������IIIIIIIIIIIIII i 0 _ff VIII^ 03 hb zV y ti T Fy� V � po Fes.► I.a cL a r � W l� 3 a m> s °Z �� ° _ � 3 g0 d D x �D w A x cm Q n O c n y D 94 1 r. to �4� W R > � v — o '4 5.6 Q v 0 A 93 0 A A < rt T 3 V to - w x A N C O N N O J �OI� O NONE 91 o ED p Lo� 2 5.6 1 1/2" TY3131 p CL QUICK al O ' D v - O o u ce T D R r � W l� 3 2 3 D `2 u 3 0 a 3 �0 D 155° a V TY3231 c n y Z c QUICK 10 (W 3 C CHROME 155° 5.6 Q v O 0 �* A DS -1 0 � o O 4 3 o oo n ° x $ 0 .575 o .ZSp pOO O NONE 91 o 3 p 7 2 5.6 1 1/2" TY3131 p TY -FRB QUICK al O - D BRASS 200' x 1 112" T D R W o o o 3 3 ...$ 1 t _ V O D O W U O CA 3 cr� I x c� �b G? . I 0 N s II im co 0 N 00 N O +/- 150' -0" REVISIONS NO. I DATE BY REVISION DESCRIPTION VX a$ �• ( o + - + 5' -0" 10' -0" - — — — — — EXISTING 12" UNDRGROUND WATER PIPE �o . c c O Cp OD C-0 ti cam i c� ►� I �, j �-.. �c- Imo. (r? I.' 0 0 CL � ► �j p +fit CD iv �p : �R'� � � � p �• � � cp 0 �p �.� � R'� n � � CD c-I- �• Q, c-t- c-+- c-+- � w 'U '�•'� o '� t/1 . o c_ CD I ti . 0 'q J +-+, RESPONSIBILITY WORK BY SG DESCRIPTION OF WORK SimplexGrin/ eII BE SAFE. SCALE: 1 / 8�� = 1 1 -0 A Tyco International Company DRAWN BY: LOCAL OFFICE: 4701 Oak Fair Blvd. Tampa, FL 33610 813 626 -5482 Al Strickland JOB NAME AND LOCATION: CHECKED BY: Fire Station #1 Zephyrhills CONTRACT WITH: 6709 Dairy Road City Of Zephyrhills Zephyerhills, Florida 33542 CONTRACT NO: SHEET DESCRIPTION: Lower Area Hydraulic Calculations 943612501 DRAWING NO. LATEST REV. DESCRIPTION: DATE: REV. #: FP-1.0 5/29/09 APPROVALS SYSTEM INFO El OUT I N SYS. #. SYS. TYPE VA. DIA. TTL. SPKC SYS. AREA El OUT IN 1 Wet 4" 167 7278 s .fl ❑ OUT IN ❑ OUT IN SPRINKLERS / NOZZLES TSH TEMP. K -FACT NPT SIN MANUFACT. MODEL # RESPONSE ESCUTCHEON) 67 PENDENT CHROME 155° 5.6 V TY3231 c n y -3 QUICK 10 (W 3 C CHROME 155° 5.6 1" TY3235 m &° DS -1 QUICK � o O 4 SIDEWALL BRASS 155° 3 $ 0 .575 o .ZSp pOO O NONE Qo 74 p 7 2 5.6 1 1/2" TY3131 TYCO TY -FRB QUICK NONE O 19 D BRASS 200' 5.6 1 112" T D TY -FRB W o o o 3 3 ...$ 1 t _ =1 g o 3 7 O� J WATER SUPPLY INFO: STATIC PRESSURE 56 PSI - RESIDUAL PRESSURE: 40 PSI WITH 1060 GPM FLOWING TEST LOCATION: Fire Hydrant South of Station BY: Zephyrhills Fire Department TEST DATE: 4/29109 z 0 N s II im co 0 N 00 N O +/- 150' -0" REVISIONS NO. I DATE BY REVISION DESCRIPTION VX a$ �• ( o + - + 5' -0" 10' -0" - — — — — — EXISTING 12" UNDRGROUND WATER PIPE �o . c c O Cp OD C-0 ti cam i c� ►� I �, j �-.. �c- Imo. (r? I.' 0 0 CL � ► �j p +fit CD iv �p : �R'� � � � p �• � � cp 0 �p �.� � R'� n � � CD c-I- �• Q, c-t- c-+- c-+- � w 'U '�•'� o '� t/1 . o c_ CD I ti . 0 'q J +-+, RESPONSIBILITY WORK BY SG DESCRIPTION OF WORK SimplexGrin/ eII BE SAFE. SCALE: 1 / 8�� = 1 1 -0 A Tyco International Company DRAWN BY: LOCAL OFFICE: 4701 Oak Fair Blvd. Tampa, FL 33610 813 626 -5482 Al Strickland JOB NAME AND LOCATION: CHECKED BY: Fire Station #1 Zephyrhills CONTRACT WITH: 6709 Dairy Road City Of Zephyrhills Zephyerhills, Florida 33542 CONTRACT NO: SHEET DESCRIPTION: Lower Area Hydraulic Calculations 943612501 DRAWING NO. LATEST REV. DESCRIPTION: DATE: REV. #: FP-1.0 5/29/09 APPROVALS SYSTEM INFO El OUT I N SYS. #. SYS. TYPE VA. DIA. TTL. SPKC SYS. AREA El OUT IN 1 Wet 4" 167 7278 s .fl ❑ OUT IN ❑ OUT IN SPRINKLERS / NOZZLES TSH TEMP. K -FACT NPT SIN MANUFACT. MODEL # RESPONSE ESCUTCHEON) 167 TOTAL SPRINKLERS / NOZZLES THIS SHEET � C�1 �(H C-+- C-,+- �� 0 ) v� �•� 0 CD CD CD n ms's GIq Q. I n ° V L I 1� O 0 y i i b N v 1 n Cp �P II y l � O 1 I " o o tZ4 ASV' �' � qi�l a n �_, . �- �' CD c-i- CD W b 6 ff� L, 1 Oi v � 9 �' � ,: W, O 5 >_ .,�' O is 0 G c ' A � 4 v .. 0) • . �� e _. d 0 w CA � I DESIGN HAZARD CLASSIFICATION AREA a 67 PENDENT CHROME 155° 5.6 1/2" TY3231 TYCO TY -FR8 QUICK 10 (W 3 PRY PENDENT CHROME 155° 5.6 1" TY3235 TYCO DS -1 QUICK DEEP 4 4 SIDEWALL BRASS 155° 5.6 1/2" TY3331 TYCO TY -FR8 QUICK NONE Qo 74 UPRIGHT BRASS 200' 5.6 1 1/2" TY3131 TYCO TY -FRB QUICK NONE O 19 UPRIGHT BRASS 200' 5.6 1 112" TY3131 TYCO TY -FRB QUICK NONE 167 TOTAL SPRINKLERS / NOZZLES THIS SHEET � C�1 �(H C-+- C-,+- �� 0 ) v� �•� 0 CD CD CD n ms's GIq Q. I n ° V L I 1� O 0 y i i b N v 1 n Cp �P II y l � O 1 I " o o tZ4 ASV' �' � qi�l a n �_, . �- �' CD c-i- CD W b 6 ff� L, 1 Oi v � 9 �' � ,: W, O 5 >_ .,�' O is 0 G c ' A � 4 v .. 0) • . �� e _. d 0 w CA � I DESIGN HAZARD CLASSIFICATION AREA a HYDRAULIC DESIGN DATA DENSITY DESIGN DES.I. AREA INSIDE 0UTSIDE 6 Of TOTAL SYSTEM REQUIREMENTS AREA LENVGTH HOSE HOSE SPRINKLERS GPMlSO.FT. SO FT FACTOR ALLOW. ALLOW, FLOWING I GPM PSI AT NODE SYMBOLS * �� 13 PIPE TO BOTTOM OF DECK 12 PIPE � TO FINISHED FLOOR ❑F WATER FLOW SWITCH TAMPER SWITCH S1 HYDRAULIC REFERENCE POINT #1 BRANCHLINE I MAIN LABEL A4 WELDED PIPE LABEL - CAP (THRU OR GRV'D) ® SYSTEM RISER -0- COUPLING (THR'D OR GRYD) + FLANGED CONNECTION r 2 -WAY EARTHQUAKE BRACE + 0AY EARTHQUAKE BRACE �` PIPE HANGER IMPORTANT NOTICE TO USER BY ACCEPTING OR USING THIS DRAWING AND /OR THE INFORMATION CONTAINED HEREIN, THE USER AGREES TO THE FOLLOWING TERMS AND CONDITIONS: THE ELECTRONIC INFORMATION IN THE DRAWING MAY BE SUBJECT TO INTENTIONAL OR UNINTENTIONAL ALTERATION. ANY USE, REUSE, COPYING MODIFICATION OR ALTERATION OF THE INFORMATION CONTAINED HEREIN SHALL BE AT THE SOLE RISK OF THE USER. THIS INFORMATION MAY NOT BE SOLD OR TRANSFERRED TO ANY THIRD PARTY, USED ON OTHER PROJECTS OR ADDITIONS TO THE PROJECT FOR WHICH IT WAS PREPARED, OR USED FOR COMPLETION OF THIS PROJECT BY ANY THIRD PARTY. SIMPLEXGRINNELL DISCLAIMS ALL LIABILITY FOR THE USE OR REUSE OF ALTERED FILES BY THE USER OR ANY THIRD PARTY AND SUCH USE WILL BE A USER'S SOLE�RISK. USER SHALL, TO THE FULLEST EXTENT PERMITTED BY LAW, DEFEND, INDEMNIFY, AND HOLD SIMPLEXGRINNELL HARMLESS FROM ANY AND ALL CLAIMS FOR LOSS, DAMAGE OR INJURY ARISING DIRECTLY OR INDIRECTLY THEREFROM. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS, THE OWNER MUST MAINTAIN HEAT THROUGHOUT WET PIPE SPRINKLER SYSTEMS AREAS, AND IN ENCLOSURES WHERE DRY PIPE, DELUGE OR OTHER VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS ARE LOCATED, ©2009 SIMPLEXGRINNELL LP -ALL RIGHTS RESERVED 1 ORDINARY GROUP 1 .15 1056 11.2 100 150 10 475 32 ase Of Rise 2 LIGHT .10 964 11.2 100 <,T ICJ 11 307 29 3ase Of Riser WATER SUPPLY INFO: STATIC PRESSURE 56 PSI - RESIDUAL PRESSURE: 40 PSI WITH 1060 GPM FLOWING TEST LOCATION: Fire Hydrant South of Station BY: Zephyrhills Fire Department TEST DATE: 4/29109 cl� c_ N c , ; > .,1 C) c., X j) I C ca -4 4. N) FfA <,T ICJ cl� c_ N c , ; > SG 30x42V G� 1 1 fj� LIZ Mo. y L ✓1 L N b �b Exi C/l p (b R `t C C c i � 9 ��o. a � B \ O x 3 N 3 �> avv � oQ p % `c O Mpg i O z a a ° v °v 3 a ip '� o a 3 na� z 10 .10 o p 1.2 S! S!. rn 5i, a «; A ❑ 4 g o _ 3 j - (q � O ? N pp 'O ° A D A O PP o V O 20 449 33 SPRINKLERS / 0. INFORMATION CONTAINED HEREIN SHALL BE AT THE SOLE RISK OF THE USER. THIS INFORMATION MAY NOT BE SOLD OR TRANSFERRED TO ANY THIRD PARTY, USED ON OTHER u CL a TEMP, K -FACT NPT SIN I« o x CHROME 155 5.6 A o N P zo °u_ PP uN m$ U 155 88 O O NO H b 3-9 H-A G t � � w H C tv� vim", J J� �� W W F I _ O OO O 1 `- - --- -- t a L - - - - - -- Ni f! / I /� * 0 +/- 160'-0 a C C c 1 PENDENT (W 3 7 x avv � oQ 2 if (' A A � $121.. 9_ o 4 fl HAZARD CLASSIFICATION AREA LENGTH HOSE HOSE AREA GPM/SQ.FT. SQ. FT. FACTOR ALLOW. ALLOW. FLOWING GPM PSI AT NODE a USER AGREES TO THE FOLLOWING TERMS AND CONDITIONS: THE ELECTRONIC INFORMATION IN THE DRAWING MAY BE SUBJECT TO INTENTIONAL OR UNINTENTIONAL ALTERATION. ANY USE, REUSE, COPYING MODIFICATION OR ALTERATION OF THE �, m M .10 a a 3 1.2 3 19 467 0 ❑ 4 LIGHT b 3 1.2 100 20 449 33 SPRINKLERS / NOZZLES INFORMATION CONTAINED HEREIN SHALL BE AT THE SOLE RISK OF THE USER. THIS INFORMATION MAY NOT BE SOLD OR TRANSFERRED TO ANY THIRD PARTY, USED ON OTHER O �PK FINISH TEMP, K -FACT NPT SIN MANUFACT. 7 CHROME 155 5.6 A o TYCO Z D QUICK FM 155 5.6 1" TY3235 TYCO DS -1 QUICK DEEP BRASS 155 33 112" r-V vo Q -1 -1 QUICK NONE BRASS S O � n 5.6 1 1/2" oc TYCO TY -FRB Q QUICK NONE a3 200° 5.6 1/2" TY3131 TYCO TY -FRB A4 WELDED PIPE LABEL -0 CAP (THR') OR GRV'D) QUICK x ; J j 'T1 11'1 r °° ' NONE i; c 8 N ® SYSTEM RISER - COUPLING PRO ORGRV'D) + FLANGED CONNECTION PERMITTED BY LAW, DEFEND, INDEMNIFY, AND HOLD SIMPLEXGRINNELL HARMLESS FROM ANY AND ALL CLAIMS FOR LOSS, DAMAGE OR INJURY ARISING DIRECTLY OR INDIRECTLY IN LOCALITIES SUBJECT TO FREEZING CONDITIONS, THE OWNER MUST MAINTAIN HEAT THEREFROM. = y ;j CF3 (j — ; °;� c ` '� �,J t p o - � o N b Q O ° r� N , 0 co o' b uo rn N 0 0 7 b Il I 0 � b, a. O N O CO 0 N 00 N O REVISIONS NO. I DATE B'( REVISION DESCRIPTION Sim /exGdnne// BE SAFE A Tyco International Company LOCAL OFFICE: 4701 Oak Fair Blvd. Tampa, FL 33610 (813) 626 -5� lOB NAME AND LOCATION: Fire Station #1 Zephyrhills 6709 Dairy Road Zephyerhills, Florida 33542 SHEET DESCRIPTION: Attic Hydraulic Calculations DRAWING NO. LATEST REV. DESCRIPTION: FP-1.1 Cf) cD H V II � ( v O V O y � O n y O f�� (3) 7 o� U1 � CD 0 c-►- c n CV w F-� n M c� orq P ° off QL I� CD Sv (aD :� O' Q' CD C CD '—� CD CD `r' C L� O , 07 ''� ''s ti • >., Sv O 1-a 0q ` o t7q I� • A _ '� O rx C-+- c-+- O CD CD co 0'q 0 a I- i O 1-1 � O �`' ' i N c�+' � p O I� O- CD n CD �' (;) O Sv O I t rr RESPONSIBILITY w SG DESCRIPTION OF WORK SG SCALE: 1/8"=1 DRAWN BY: Al Strickland CHECKED BY: CONTRACT WITH: City Of Zephyrhills CONTRACT NO: 943612501 DATE: RE 5/29/09 — — — — — — EXISTING 12" UNDRGROUND WATER PIPE QQ 67 1 PENDENT (W 3 DRY PENDEf d 4 SIDEWALL oQ 74 UPRIGHT n I 19 UPRIGHT 167 TOTAL SPRINKLERS / NOZZLES THIS SHEET I' • IZ F-J v �' C-i- �^ ~ y vl _ c -+- � � n F�a f_a �o C � �O I (D 0 q i'8 I ;s� > J :3. i13 p v 63 ' W CA of c® 3 3 3 ' s, L D to K]i c3 J O 5 1yj LU A I� � N 3 bi > n HYDRAULIC DESIGN DATA APPROVALS IMPORTANT NOTICE TO USER SYSTEM INFO ❑ E] OUT - I N OUT IN SYS. #. SYS. TYPE 1 Wet VA. DIA. TTL. SPK. 4 167 SYS. AREA 7278 s .ft BY ACCEPTING OR USING THIS DRAWING AND /OR THE INFORMATION CONTAINED HEREIN THE ,' D ; D y +` HAZARD CLASSIFICATION AREA LENGTH HOSE HOSE AREA GPM/SQ.FT. SQ. FT. FACTOR ALLOW. ALLOW. FLOWING GPM PSI AT NODE 12-4 PIPE � TO FINISHED FLOOR ❑F WATER FLOW SWITCH USER AGREES TO THE FOLLOWING TERMS AND CONDITIONS: THE ELECTRONIC INFORMATION IN THE DRAWING MAY BE SUBJECT TO INTENTIONAL OR UNINTENTIONAL ALTERATION. ANY USE, REUSE, COPYING MODIFICATION OR ALTERATION OF THE > 1 7 f�3 d ❑ LIGHT .10 OUT IN 1.2 100 19 467 33 ❑ 4 LIGHT OUT IN 1500 1.2 100 20 449 33 SPRINKLERS / NOZZLES INFORMATION CONTAINED HEREIN SHALL BE AT THE SOLE RISK OF THE USER. THIS INFORMATION MAY NOT BE SOLD OR TRANSFERRED TO ANY THIRD PARTY, USED ON OTHER ni C �PK FINISH TEMP, K -FACT NPT SIN MANUFACT. MODEL # RESPONSE ESCUTCHEON / SPR CHROME 155 5.6 1/2" TY3231 TYCO TY -FRB QUICK CHROME 155 5.6 1" TY3235 TYCO DS -1 QUICK DEEP BRASS 155 5.6 112" TY3331 TYCO TY -FRB QUICK NONE BRASS 200° 5.6 1 1/2" TY3131 TYCO TY -FRB QUICK NONE BRASS 200° 5.6 1/2" TY3131 TYCO TY -FRB A4 WELDED PIPE LABEL -0 CAP (THR') OR GRV'D) QUICK x ; J j 'T1 11'1 r °° ' NONE c 167 TOTAL SPRINKLERS / NOZZLES THIS SHEET I' • IZ F-J v �' C-i- �^ ~ y vl _ c -+- � � n F�a f_a �o C � �O I (D 0 q i'8 I ;s� > J :3. i13 p v 63 ' W CA of c® 3 3 3 ' s, L D to K]i c3 J O 5 1yj LU A I� � N 3 bi > n HYDRAULIC DESIGN DATA SYMBOLS IMPORTANT NOTICE TO USER SIDE . TF DENSITY DESIGN DES AREA INSIDE OU DESIGN SPR! O INIdERS TOTAL SYSTEM REQUIREMENTS * " 13 PIPE TO BOTTOM OF DECK BY ACCEPTING OR USING THIS DRAWING AND /OR THE INFORMATION CONTAINED HEREIN THE ,' D ; D y +` HAZARD CLASSIFICATION AREA LENGTH HOSE HOSE AREA GPM/SQ.FT. SQ. FT. FACTOR ALLOW. ALLOW. FLOWING GPM PSI AT NODE 12-4 PIPE � TO FINISHED FLOOR ❑F WATER FLOW SWITCH USER AGREES TO THE FOLLOWING TERMS AND CONDITIONS: THE ELECTRONIC INFORMATION IN THE DRAWING MAY BE SUBJECT TO INTENTIONAL OR UNINTENTIONAL ALTERATION. ANY USE, REUSE, COPYING MODIFICATION OR ALTERATION OF THE > 1 7 f�3 d 3 LIGHT .10 1500 1.2 100 19 467 33 ase Of Rise 4 LIGHT .10 1500 1.2 100 20 449 33 Base Of Rise T❑ TAMPER SWITCH 0 HYDRAULIC REFERENCE POINT INFORMATION CONTAINED HEREIN SHALL BE AT THE SOLE RISK OF THE USER. THIS INFORMATION MAY NOT BE SOLD OR TRANSFERRED TO ANY THIRD PARTY, USED ON OTHER ni C #1 BRANCHLINE I MAIN LABEL PROJECTS OR ADDITIONS TO THE PROJECT FOR WHICH IT WAS PREPARED, OR USED FOR DISCLAIMS ALL ., 3a 0 COMPLETION OF THIS PROJECT BY ANY THIRD PARTY. SIMPLEXGRINNELL A4 WELDED PIPE LABEL -0 CAP (THR') OR GRV'D) LIABILITY FOR THE USE OR REUSE OF ALTERED FILES BY THE USER OR ANY THIRD PARTY AND SUCH USE WILL BE A USER'S SOLE RISK. USER SHALL, TO THE FULLEST EXTENT x ; J j 'T1 11'1 r °° ' ® SYSTEM RISER - COUPLING PRO ORGRV'D) + FLANGED CONNECTION PERMITTED BY LAW, DEFEND, INDEMNIFY, AND HOLD SIMPLEXGRINNELL HARMLESS FROM ANY AND ALL CLAIMS FOR LOSS, DAMAGE OR INJURY ARISING DIRECTLY OR INDIRECTLY IN LOCALITIES SUBJECT TO FREEZING CONDITIONS, THE OWNER MUST MAINTAIN HEAT THEREFROM. = y ;j CF3 (j — ; °;� c ` '� �,J t p o - r 2 - WAY EARTHQUAKE BRACE THROUGHOUT WET PIPE SPRINKLER SYSTEMS AREAS, AND IN ENCLOSURES WHERE DRY a7 WATER SUPPLY INFO: STATIC PRESSURE 56 PSI -RESIDUAL PRESSURE: 40 PSI WITH 1060 GPM FLOWING + 4WAY EARTHQUAKE BRACE PIPE, DELUGE OR OTHER VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS TEST LOCATION: Fire Hydrant South of Station BY: Zephyrhills Fire Department TEST DATE: 4/29/09 - t - PIPE HANGER ARE LOCATED. © 2009 SIMPLEXGRINNELL LP -ALL RIGHTS RESERVED _ 6