09-9424
CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780 -0020 9424 FIRE SPRINKLER SYSTEM PERMIT F,,•:: E `' s ie. r `, a g { < Z '•. 1 '.g. -` $� 7777 Permit Number: 9424 Address: 7940 GALL BLVD Permit Type: FIRE SPRINKLER SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE - SPRINKLER SYS Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 35-25-21-0130-0000000140 Improv. Cost: 1,450.00 Date Issued: 8/14/2009 Name: ZEPHYR COMMONS LLC Total Fees: 210.00 Address: 3629 MADACA LN Amount Paid: 210.00 TAMPA FL 33618 Date Paid: 8/14/2009 Phone: (954)596 -6883 Work Desc: SPRINKLER SYSTEM MODIFICATION SET THEM UPRIGHT FIR N R V „• EE.... >50 5 dA FIR PRINKLER YS 50.00 W FEE 50.00 FIRE INSPECTION FEES 110.00 l it ?L £ 3 0' • 9 � '. �^��a� a �,a u ' s��''.�8 .`� � s� „- "�_ r "a ° � - � � �� ... � .. � a.... .., .. ... .. $ .. 9 �s. .. ..a" IRE -P= SUR ST FIRE ACCEPTANCE Final Chapter 633, Florida Statutes, authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees, and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of $100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." l! CONTRACT' - SIGNATURE • 7 d 1 • IC R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT - Fire Marshal Office - 813- 780 -0041 qtqC1 813-780 -0020 City of Zephyrhills Permit Application Fax -813 -780 -0021 Building Department t AA A) ' ll '" ` �O G L a � c� ! ► /tom Date Received , S-'(© .- , 1 Phone Contact for Permitting I r ffia - 4 Owner's Name 4 # 7 " „1 I`-L Owner Phone Number Owner's Address Owner Phone Number 1 Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address [ JOB ADDRESS - 7 6 7 4 1 - 0 int- gLVL . r 1 rety oV c y l5�" LOT # SUBDIVISION PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD /ALT n SIGN n MOVE n DEMOLISH INSTALL REPAIR PROPOSED USE n SFR rac COMM Q OTHER TYPE OF CONSTRUCTION n BLOCK p n FRAME � //' / , = STEEL n OTHER I DESCRIPTION OF WORK [ oFt- cor Vi Cs-r � pm 4kL is 7 BUILDING SIZE I X 1 .g SQ FOOTAGE / 11 HEIGHT (0 fttommttotattittEttfttmatitottlitm n BUILDING ( Zi t S ` 00 VALUATION OF TOTAL CONSTRUCTION n ELECTRICAL AMP SERVICE n PROGRESS ENERGY n W.R.E.C. n PLUMBING n MECHANICAL VALUATION OF MECHANICAL INSTALLATION I GAS n ROOFING I 1 SPECIALTY OTHER FINISHED FLOOR ELEVATIONS [ FLOOD ZONE AREA nYES El NO BUILDER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y/ N I Address ( License # ELECTRICIAN COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y/ N I Address I License # I PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y/ N I Address I License # 1 MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURRENT I Y/ N I Address ( License # I i l OTHER 7 /44 ` COMPANY l sC /✓" SIGNATURE 2 ,, �7 REGISTERED I Y/ N I FEE CURRENT' I Y/ N I F#4)( Address Q #4)S /`L I�.cvtw Da -. , 'PA ( 3 .7 619 License 1+ IffilMIONSMINIZSMINVIERIMIORM RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R -O -W Permit for new nstruction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Storm ter Plans w/ Silt Fence installed,,, - Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects _ - COMMERCIAL Attach (3) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R -O -W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $5000) Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades NC Fences (Plot/Survey /Footage) Driveways -Not over Counter if on public roadways..needs ROW Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (813) 780 -0041 Kerry Barnett Fax (813) 780 -0044 E -mail: kbarnett@fire.zephyrhills.fl.us Plan Review #: 09 -066 Project: Sprinkler Modification Number of Pages: 1 plus spec packet July 27, 2009 I have received and reviewed the plan for the sprinkler modification located at 7940 Gall Blvd and will allow this to move forward. Obtaining permit, the applicant acknowledges complying with the items listed below. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. 1. This modification shall be compliant with the 2007 edition of NFPA 13. 2. Ensure there are spare sprinkler heads of this type in cabinet. Inspections Required: 1. Pressure Test 2. Final KERR , , BARNETT, FIRE MARSHAL ***Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Fire Chief Keith Williams Bus (813)780 -0041 Fax (813)780 -0044 FIRE SERVICE USER FEES Occupancy N : Plan No.: G?�, Contractor: / ��.� Business ame: Billing Address:.�i� , ,/,- Business Address 7/�- , .•, , ..e - --/y Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: _ PLAN REVIEW FEES _ INSPECTION FEES PERMIT FEE FALSE ALARM FEE Site Plan N/C _ Annual N/C L — A . prinkler $50 — 1st Alarm N/C _ Multi Family /Commercial .06 sf _ 1st Re- inspection N/C ■ Standpipes _ 2nd Alarm N/C (Minimum Charge $25.00 _ 2nd Re- inspection $100 , Fire Pump $50 _ 3rd Alarm N/C 0 Plan Revisions DBL _ 3rd Re- inspection $250 , Hoods $50 _ 4th Alarm $100 4th Re- Inspection $500 , Fire Alarm $50 _ 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until , LP Gas $50 _ 6th Alarm $200 0 - 25 Heads '•50 violations corrected) , Natural Gas $50 _NON COMPLIANCE $150 6 plus Heads ' 1 SPRINKLER SYSTEMS , Fuel Tanks - per tank $50 STANDPIPE SYSTEM , Hydro Undergrounds $45 , Sparklers $100 ❑ Per Riser $50 le` Hydrostatic Test r system , Fire Works $500 FIRE PUMP Acceptance Test rsystem 1 Camp Fire $25 0 Per Pump $100 41 Hydrant Flow , Controlled Bum $100 FIRE ALARM SYSTEM , Hood /Duct $50 0 - 25 Devices $50 _ FIRE ALARM SYSTEM II Place of Assembly $50 Annual 26 plus Devices $100 _ System Acceptance $50 , Fire Protection $25 SUPPRESSION SYSTEMS _ Recall Acceptance $50 , Flammable Application $50 Annual Wet $50 _ OTHER , Waste Tire Storage $50 Annual Dry $50 ` Fire Wall /smoke Wall $15 per wan , Generator < KW $100 CO2 $50 _ LP Gas $25 per tank , Generator >30 KW 150 Other $50 ,_ Natural Gas $25 per system , Bio-Hazard Waste $100 Annual KITCHEN EXHAUST _ , Fumigation Tenting $50 0 Hood/Ducts $50 _ Tent 10'x10' or greater $15 per tent , Torch Pot/Applied $50 OTHER _ Fire Pump $45 , Haz. Materials $100 Annual LP Installation per tank $ _ Fire Suppression $30 Fuel Tank Installation $50 _ System Acceptance (Per Tank) $50 _ Exhaust Hood /Duct $30 El Natural Gas Installation $50 _ Re - inspection DBL (Per System) (other than annual) 0 Spray Booth $50 0 Inspection scheduled DBL and cancelled less than _ _ 24 hours — Construction Insp. N/C 4)'''' Emergency Vehicle Act $50 i FALSE ALARM PLANS TOTAL INSPECTION TOTAL V PERMIT TOTAL TOTAL GRAND TOTAL 1 L1T) 1 Comments: Date: 'i 1 g Vii Ins ctor: Yd (6 41 , • Capsco Industries 8445 East Adamo Drive Tampa, Florida 33619 Ph: 813- 628 -4700 Fx: 813- 628 -4766 FLORIDA LICENSE NO. 14044500012009 Building Dept. Permit #9209 Equipment Material Submittals for Tenant "B5" at Zephyr Commons 7940 Gall Blvd. (U.S. Hwy 301) Zephyrhills, Florida 33541 General Contractor: Hawkins Construction, Corp. 1430 L & R Industrial Blvd. Tarpon Springs, Florida 34689 Ph: (727) 938 -9719 SUBMITTED ' /• () HAVE BEEN REVIEWED BY ZEPH , :t� ,. i; MARSHAL'S OFFICE Date: ' j L .1 ,� / /� Reviewer: /— �� /t.�/ Tenant "B5" at Zephyr Commons Equipment Material Submittal Table of Contents Sprinkler Heads & Accessories Manufacturer Model "M" Quick Response (Upright, Pendent) Viking Misc. Material Hilti UL Listed Details HILTI FS -ONE Firestop / Sound Stop Sealant HILTI Industrial Bulk Wool Thermafiber Above Ground Piping Fittings Threaded Cast Iron Nipples & Fittings AnvilStar Hangers & Hanger Material 3/8" Universal C -Clamp AnvilStar Intl. Inc. 1" Adjustable Loop Hanger AnvilStar Intl. Inc. 3/8" Zinc Plated All Thread Rod AnvilStar Intl. Inc. Above Ground Piping 1" Sched 40 Pipe (Thrd) Allied Fire Protection Shop Drawing Capsco Industries Under Separate Cover (24 x 36) Capsco Industries 8445 East Adamo Drive, Tampa, FL 33619 Ph: 813- 628 -4700 Fx: 813 - 628 -4766 • August 27, 2004 Sprinkler 41 a NIKING® MICROFASr & MicrofastHP TECHNICAL DATA QUICK RESPONSE PENDENT SPRINKLERS 1. PRODUCT NAME 12104. Copper UNS- C19500 for Viking Microfast® and MicrofastHP® Sprinkler 12282. Brass UNS-C26000 Model M Quick Response Pendent for all other Part Nos. Sprinklers Bushing (for Sprinkler Base Part Nos. 2. MANUFACTURER 06718B, 06720B, and 12290): Brass _ UNS- C36000 The Viking Corporation Bulb: Glass, nominal 3 mm diameter 210 N. Industrial Park Road Belleville Spring Sealing Assembly: Hastings, Michigan 49058 U.S.A. Nickel Alloy, coated on both sides Telephone: (269) 945 -9501 with Teflon Tape (877) 384 -5464 Screw: Brass UNS- C36000 Fax: (269) 945 -9599 Pip Cap and Insert Assembly: Copper e -mail: techsvcs @vikingcorp.com UNS- C11000 and Stainless Steel 3. PRODUCT DESCRIPTION 4. TECHNICAL DATA UNS- S30400 Viking Microfast® and MicrofastHP® LISTINGS AND APPROVALS Pip Cap Attachment: Brass UNS- C36000 Quick Response Pendent Sprinklers Refer to the Approval Chart on page 41 b. Ejector Spring (Part No. 12104): Stain are small, thermosensitive spray sprin- Glass -bulb fluid temperature rated to less Steel klers available with several finishes, -65 °F ( -55 °C). Sprinklers with Teflon® Coating temperature ratings, and orifice sizes to Minimum Operating Pressure: 7 psi Belleville Spring: Nickel Alloy, exposed meet design requirements. The special (48,3 kPa) Screw: Brass UNS- C36000, Nickel Poly finishes and Teflon coatings can RATED WATER WORKING PRES- plated be used in decorative applications SURE Pip Cap: Teflon® Coated where colors are desired. In addition, Sprinklers VK317 and VK342 are Sprinklers with Polyester Coating or these two finishes are corrosion resis- rated for use with water working Poly Finish tant and provide protection against pressures ranging from the mini- Belleville Spring: Nickel Alloy, exposed many corrosive environments. mum 7 psi (48,3 kPa) up to 250 psi (1 AVAILABLE FINISHES The pip cap and sealing assembly of the 724 kPa) for high - pressure sys- Brass, Chrome- Enloy® (patents pend- sprinkler is held in place by a bulb tye tams. High- pressure (HP) sprin- ing), White Polyester (White Poly finish operating element. During fire condi- kiers can be Identified by locating for Sprinkler 06662B), Black Polyester tions, when the temperature around the the number "250" on the deflector. (Black Poly finish for Sprinkler 06662B), sprinkler reaches its operating tempera- All Other Sprinklers: Maximum 175 and Black Teflon® ture, the heat - sensitive liquid in the psi (1 207 kPa) wwp. ACCESSORIES glass bulb expands, causing the bulb to Factory tested hydrostatically to 500 psi Sprinkler Cabinets (Available since shatter, releasing the pip -cap and seal- (3 448 kPa). 1971): ing spring assembly. Water flowing Testing: U.S.A. Patent No. 4,831,870 A. Six -head capacity: Part No. through the sprinkler orifice strikes the SPRINKLER MATERIALS 01724A sprinkler deflector, forming a uniform Frame: Brass Castings UNS- C84400 B. Twelve -head capacity: Part No. spray pattern to extinguish or control the Deflector: Brass UNS- C51000 or Cop- 01725A fire. per UNS- C19500 for Sprinkler Base Sprinkler Wrenches: Part Nos. 06662B, 06666B, 06765B, A. Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Temperature Nominal Sprinkler Temp. Maximum Ambient Bulb or 05000CW /B (no longer avail- Classification Rating (Fusing Point) Ceiling Temperature Color able). Ordinary 155 °F (68 °C) 100 °F (38 °C) Red B. Wrench for coated and recessed Intermediate 175 °F (79 °C) 150 °F (85 °C) Yellow Viking Microfasts and MicrofastHP's Intermediate 200 °F (93 °C) 150 °F (65 °C) Green QR Pendent Sprinklers: Part No. High 288 °F (141 °C) 225 °F (107 °C) Blue 07398W* (available since 1990), Sprinkler Finishes: Brass, Chrome - Enloy® (patents pending), White Polyester (White Poly or Part No. 12144W/B ", available finish for P/N 06662B), Black Polyester (Black Poly finish for P/N 06662B), and Black Teflon° since 2003. NOTE: Recessed Corrosion - Resistant Coatlngs White Polyester (White Poly finish for P/N 06662B), Black pendent sprinklers with protec- Polyester (Black Poly finish for P/N 06682B), and Black Teflon® tive caps must use wrench Footnotes 12144W/B. 1 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, 'A I" ratchet Is required (not available through and other requirements of the Authority Having Jurisdiction. Refer to specific installation Viking). standards. Refer to the "SPRINKLER ACCES- 2 The temperature rating is stamped on the deflector. SORIES" section of the Viking Engi- 3 The corrosion - resistant coatings have passed standard corrosion tests required by particu- neering and Design Data book. I ar approving agencies. Refer to the approval chart on page 41 b. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. The coatings indicated are applied to the exposed exterior surfaces only. NOTE: The spring is exposed on sprinklers with Teflon® Coating or Poly finishes. Note: Units of measure in parentheses may be approximations. Replaces page 41 a -b, dated May 14, 2004 (updated deflector Form No. F_081296 materials). Refer to technical data page QR1 -2 for care, in- stallation, and maintenance information. Sprinkler 41 b r I � . " August 27, 2004 MICROFAST®& MicrofastHP® � 1 _ -, -- i.. N i k : QUICK RESPONSE PENDENT SPRINKLERS Approval Chart Temperature KEY MIcrofaste and MlcrofastHP ®Quick Response �� Finish Pendent Sprinklers AI X 4 – Escutcheon (if applicable) Maximum 175 PSI WWP Standard • rrice u Base Part ...0 �.: . .,« . • r _ NPT NM Number' SIN e . �� �� A. • U.S. metric " cULus 6 FM9 NYC VdS LPCB CE s " —OP r u u �, r - �� _•�•1•I•L7 ' m 1' r • i �� a -'' - — - ' " 11 n " 1 M — - — -- Small Orifice /2" 15 mm 175 087180 VK329 2.8 4.0 2 -3/16 W _ 56 A3X�3Y I _ ' – – 'A" 15 mm 175 067208 VK331 4.2 6,0 2 -1/4 58 _ A3X.33Y1 – 10 mm __ -175 06932B VK331 4.2 6,0 2 -3/8 60 – – 3X " – - Maximum 250 PSI WWP Standard _ Z — � — Standard Orifice NPT - . I T r :! Base Part SIN " Number { cULus FM NYC' VdS LPCB CE nu i'�ilrL! %2" 1 15 mm 1 250 I 12290 VK3421 2.8 I 4 2 1 56 I A3X. B3Y 1 I A3X I - I 1 – Approved Temperature Ratings Approved Finishes Approved Escutcheons X 1 - Brass, Chrome- Enloye, White Poly inish Black Standard surface mounted escutcheon A - 155 °F (68 °C), 175 °F (79 °C), 200 °F Poly Finish and Black Teflon ®li or the Viking Microfaste Model F -1 Ad (93 °C), and 286 °F (141°C) 2 - Brass and Chrome- Enloy® justable Escutcheon l° B -155 °F (68 °C), 175 °F(79 °C), and 200 °F 3 - Brass, Chrome- Enloye White Polyester " ", Black Y - Standard surface -mountgd, escutch- (93 °C) Pdyester and Black Te11on� eon or the Viking Microfasf Model F -1 C - 155 °F (68 °C) 4 - Brass, Chrome- Enloye, White Poly Finish, and Adjustable Escutcheon or recessed Black Poly Finish E - 2 the Vidng Miaomatic Model E -1 or E - ___ Footnotes — Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 3 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219- 76 -SA. 4 The sprinkler orifice is bushed. 5 CE Certified, Standard EN 12259 -1, EC- certiflcate of conformity 0832 -CPD -2001. 6 Listed by Underwriters Laboratories Inc. for use In the U.S. and Canada. e cULus Listings and NYC Approvals limited to Light - Hazard Occupancies with hydraulically calculated wet systems. 9 FM Metric K- Factor is for use when pressure is measured in kPa. When pressure is measured in BAR, multipy the metric K- Factor shown by 10.0. Approved for use only in wet -pipe sprinkler systems (or preaction systems quaifying as wet systems) for protection of occupancies de- scribed in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. 1° The Viking Microfast' Model F-1 Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusibleel e- � ment of the sprinkler to be recessed behind the face of the wall or ceiling. cULus Listed as corrosion resistant. 12 Accepted for use, City of New York Department of Buildings, MEA 89 -92 -E, Vol XVI. 13 Refer to the "Sprinkler Accessories" section of the Viking Engineering and Design Data book for technical data on approved escutcheons and other accessories. Quick Response Pendent Sprinkler 2 -1/8" with a Standard 1/8" (3,1 mm) � (54 mm) t 2 - /8" f Surface - Mounted Escutcheon (54 mm) t lum 2_1/4" ; III i 2" 1" 0 7� S1 mm i 1 -1/2" (32 mm) � i 1 o ' ' 1 -3/4" ( ) oil � Minimum Maximum lirt (45 mm ) _ 1 _ ;/4" I rl� Ii -1/9" (28,6 mm) (45 mm) I Minimum Quick Response + +- Maximum ___jf__ Pendent Sprinkler Quick Response Pendent Sprinkler "...1..- Installed with the Viking Microfast® Ceiling Opening Size: 2 -5/16" (59 mm) Minimum, Model F -1 Adjustable Escutcheon Quick Response Pendent Sprinkler 2 -1/2" (84 mm) Maximum. Installed with the Viking Micromatice Figure 1 Model E-1 Recessed Escutcheon Replaces page 41 a -b, dated May 14, 2004 (updated deflector materials). Refer to tech- Form No. F081296 nical data page QR1 -2 for care, installation, and maintenance information. - i May 14, 2004 e' A( -r1 N� Sprinkler 51 a MICROFAST* AND NIKING® TECHNICAL DATA MicrofastHP QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS PRODUCT NAME Spring: U.S.A. Patent No. 4,167,974 Viking Microfast® and MicrofastHP® Bulb: U.S.A. Patent No. 4,796,710 411 ;;; Model M Quick Response Upright and `� , k..4 > Testi: U.S.A. Patent No. 4,831,870 Conventional Sprinklers 1 4 ' SPRINK nge: Brass M Castings UNS- 084400 ATERIALS Fram 2. MANUFACTURER Deflector: Copper UNS- C19500 for The Viking Corporation Sprinkler Base Part Nos. 06661B, 210 N. Industrial Park Road 1 06665B, 06764B, 07060, and 12281. Hastings, Michigan 49058 U.S.A. . . Brass UNS- C26000 for all other Part Telephone: (269) 945 -9501 Nos. (877) 384 -5464 Bushing (for Sprinkler Base Part Nos. Fax: (269) 945 -9599 onventl • .1 Upright 06719B, 06717B, and 12286): Brass e -mail: techsvcs @vikingcorp.com UNS- C36000 3. PRODUCT DESCRIPTION leasing the pip -cap and sealing spring Bulb: Glass, nominal 3 mm diameter g Microfaste and MicrofastHP® assembly. Water flowing through the Belleville Spring Sealing Assembly: Vikin Response Upright and Conven- sprinkler orifice strikes the sprinkler de- Nickel Alloy, coated on both sides Quick Re tional Re s Style) Sprinklers are small Hector, forming a uniform spray pattern with Teflon Tape thermosensitive spray sprinklers to extinguish or control the fire. Screw: Brass UNS-C36000 equipped with a 3 mm glass bulb. 4. TECHNICAL DATA Pip Cap and Insert Assembly: Copper Viking Microfast® and MicrofastHP® LISTINGS AND APPROVALS UNS- and Stainless Steel UNS- s30 30400 Quick Response Upright and Conven- RefertotheApproval Charton page 51 b. Sprinklers with Teflon® Coating tional Sprinklers are available with sev- Glass -bulb fluid temperature rated to Belleville Spring: Nickel Alloy, exposed eral finishes, temperature ratings, and -65 °F ( -55 °C). Screw: Nickel plated orifice sizes to meet design require- Minimum Operating Pressure: 7 psi Pip Cap: Teflon® Coated ments. The special Polyester and Tef- (48,3 kPa). Sprinklers with Polyester Coating lone coating can be used in decorative RATED WATERWORKING PRESSURE Belleville Spring Sealing Assembly: applications where colors are desired. Sprinklers VK315 and VK340 are Exposed In addition, the Polyester and Teflon rated for use with water working AVAILABLE FINISHES coatings are corrosion resistant, provid- pressures ranging from the mini- Brass, Chrome -Enlo (patents nd- ing protection against many corrosive mum 7 psi (48,3 kPa) up to 250 psi (� environments. kPa) for high-pressure s s- for P 1 Part Nos. Polyester (White Poly finish (1 724 kP ( ) y for Part Nos. 06661 B, 06665B, 06764B, The pip cap and sealing assembly of the tams. High- pressure (HP) sprin- 07060, and 12281), Black Polyester sprinkler is held in place by a 3 mm glass klers can be identified by locating (Black Poly finish for Part No. 0666113), bulb. During fire conditions, when the the number "250" on the deflector and Black Teflon® temperature around the sprinkler All Other Sprinklers: Maximum 175 ACCESSORIES reaches its operating temperature, the psi (1 207 kPa) wwp. Sprinkler Cabinets: heat - sensitive liquid in the glass bulb ex- Factory tested hydrostatically to 500 psi A. Six -head capacity: Part No. 01724A pands, causing the bulb to shatter, re- (3 448 kPa). B. Twelve -head capacity: Part No. Sprinkler Temperature Nominal Sprinkler Temperature Max. Ambient Bulb 01725A Classification Rating (Fusing Point) Ceiling Temp! Color Available since 1971. Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Sprinkler Wrenches: Intermediate 175 °F (79 °C) 150 °F (85 °C) Yellow A. Standard Sprinkler Wrench: P a rt Intermediate 200 °F (93 °C) 150 °F (85 °C) Green N o. 10896W/B (available since High 288 °F (141 °C) 225 °F (107 °C) Blue 2000) or 05000CW /B (no longer Sprinkler Finishes: Brass, Chrome - Enloy (patents pending), White Polyester (White Poly available). finish for Part Nos. 06681B, 068658, 06764B, 07060, and 12281), Black Polyester (Black B. Wrench for coated and recessed Poly finish for Part No. 08681 B), and Black Teflon® sprinklers: Part No. 07398W" Corrosion Resistant Coatings White Polyester (White Poly finish for Part Nos. • A W ratchet is required (not available 06661B, 06665B, 06764B, 07060, and 12281), Black Polyester (Black Poly finish for from Viking). Part No. 06661B), and Black Teflon® Refer to the "SPRINKLER ACCES- Footnotes SORIES" section of the Viking Engi- 1 Based on NFPA Other limits may apply, depending on fire loading, sprinkler location, nearing and Design Data book. and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 2 The temperature rating is stamped on the deflector. 3 The corrosion - resistant coatings have passed standard corrosion tests required by particu- lar approving agencies. Refer to the approval chart on page 51 b. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. The coatings indicated are applied to the exposed exterior surfaces only. NOTE: The spring is exposed on sprinklers with Polyester Finishes and Tefon® coating. Table 1 Note: Units of measure in parentheses Replaces page 51 a-b, dated February 27, 2004 (Sprinkler 06931B is now VK327). may be approximations. Refer to technical data page QR1 -2 for general care, Installation, and mainte- Form No. F_080488 nance information. ---- ) Sprinkler 51 b I ST J / v �{ __. May 14, 2004 NilaNG ® MICROFAS '' AND i= , .� , I , , f, MicrofastHP QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS Approval Chart 1 Temperature KEY Microfast®and MicrofastHP®Quick Response li Finish - -- __ Upright and Conventional Sprinklers AI X. Escutcheon (if applicable) Maximum 175 PSI WWP Standard Orifice Thread Size Max. Nominal Overall Pressure Sprinkler Description Listings and Approvals K- facto: Length NPT BSP PSIG Sprinkler Base Part No. SIN U.S. metric Inches mm cULus FM NYC VdS LPCB (( '' /z" 15 mm 175 Upright 0666113 VK300 5.6 8,1 2 -3/16 56 A6 Al A6 _ -- 15 mm 175 Upright 07060 VK345 5.6 8,1 2 -3/16 58 - A3 B1 A7 A7 /z" 15 mm 175 Conventional 06766B VK310 5.6 8,1 2 -3/16 56 A5 - A5 - A5 A5 Large Orifice — 3/4" 20 mm 175 Upright 06665B VK350 8.0 11,5 2 -5/16 59 A4 A3 A4 B1 - - '/" 20 mm 175 Upright 067646 VK350 8.0 11,5 2 -5/16 59 A4 - A4 3/4" 20 mm 175 Conventional 06768B VK354 8.0 11,5 2 -5/16 59 A5 _ A5 - - -- Small Orifices ' /z" 15 mm 175 Upright 0671713 VK325 2.8 4,0 2 -3/16 56 A2 Al A2 W 15 mm 175 Upright 06719B VK327 4.2 8,0 2 -3/18 56 A2 - A2 - - 10 mm 175 Upright 06931B VK327 4.2 6,0 2 -3/16 56 - - - B1 - -- Maximum 250 PSI WWP Standard Orifice Thread Size Max. Nominal Overall Pressure Sprinkler Description Listings and Approvals K -facto Len th NPT BSP PSIG Style Base Part No. SIN U.S. metric Inches mm cULus FM NYC VdS LPCB ( E 'Y2 " 15 mm 250 Upright 12281 VK315 5.6 8,1 2- 3/1 58 A2 A2 Small Orifices _ %z" 15 mm 250 1 Upright 12288 VK340I 2.8 4,0 1 2- 3/16 56 A2 - A2 - - Approved Finishes Approved Temperature Ratings 1 - Brass and Chrome-Enloe 2 - Brass, Chrome -Enby® White Polyester Black Polyester and Black Teflon ®7 A - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 3 - Brass, Chrome- Enloy®, and White Poly Finish 286 °F (141°C) 4 - Brass, Chrome -Enby® White Poly Finish Black Polyester, and Black Teflon ® B - 155 °F (68 °C) 5 - Brass, Chrome EnIoy®, White Polyester and Black Polyester' 6 - Brass, Chrome -Enloy® White Poly Finish Black Poly Finish and Black Teflon ® 7 - Brass, Chrome- Enloy ®, White Poly Finish, and Black Poly Finish Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. a CE Certified, Standard EN 12259 -1, EC- certificate of conformity 0832 -CPD -2001. The sprinkler orifice is bushed. s Listings and Approvals are limited to Light - Hazard occupancies with hydraulically calculated wet systems only. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 7 cULus Usted and NYC Approved as corrosion- resistant. 8 FM Approved for use In wet pipe sprinkler systems for preaction systems qualifying as wet systems) for protection of occupancies described in e the Factory Mutual Global Loss Prevention Data Sheets and Technical Advisory Bulletins. 9 letric K-Factor shown Is for use when pressure is measured in kPa. When pressure is measured in BAR, multiply the metric K-Factor shown by 10.0. Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 11 Accepted for use, City of New York Department of Buildings, MEA 89 -92 -E, Vol. 16. Replaces page 51 a -b, dated February 27, 2004 (Sprinkler 06931 B is now VK327). Refer to Form No. F technical data page QR1 -2 for general care, installation, and maintenance information. UutI rform. OutIII ^,t Firestop Submittal • 800 - 879 -8000 www. hilti. us Sprinkler Submittal: Flat Concrete Metallic & Combustible Penetrants (Cast -In Option) Barrier Penetration Type Max. Penetration Size Annular Space F- Rating System Product Number Steel, Cast Iron, Copper, Steel Conduit, 4" EMT; 6" others CP 680P / M; Floor Co pp (See Detail) 3 hours F -A -1017 CP 618 EMT Floor PVC CPVC RNC 6" all See Detail 3 hours F -A -2054 CP 680P Floor ABS FRPP 4" ABS. 6" FRPP See Detail 3 hours F -A -2066 CP 680P Barrier Penetration Type Max. Penetration Size Annular Space F- Rating System Product Number Steel, Cast Iron, 30" Steel or Cast Iron; Wall Copper, Steel Conduit, 6" Copper or Steel 0" to 2 -1/4" 1 or 2 ho W -L -1054 FS One EMT Conduit 4" EMT - PVC, CPVC, ABS, 10" PVC or CPVC; 6" FS One; CP Wall FRPP, PVDF ABS or FRPP; 4" PVDF 0" to 1/2" 1 or 2 hours W -L -2078 643N or CP 644 Wall PVC, CPVC 2" either 1/4" to 11/16" 1 or 2 hours W -L -2128 FS One a qiIr Barrier Penetration Type Max. Penetration Size Annular Space F- Rating System Product Number Steel, Cast Iron, 30" Steel or Cast Iron; Floor / Wall Copper, Steel Conduit, 6" Copper or Steel 0" to 1 -7/8" 3 hours C -AJ -1226 FS One EMT Conduit 4" EMT 6" and smaller PVC, CPVC, ABS, 10" PVC or CPVC; (0" to 1/2 "); CP 643; or Floor / Wall FRPP 6" ABS or FRPP larger than 6 ": 2 or 3 hours C -AJ -2109 CP 644; FS 0" to 1 -1/4" One Floor / Wall PVC, CPVC 3" either 1/2" to 2" 3 hours C -AJ -2141 FS One; CF 810 orCF812 Barrier Penetration Type Max. Penetration Size Annular Space F- Rating System Product Number Steel, Cast Iron, 30" Steel or Cast Iron; Wall Copper, Steel Conduit, 6" Copper or Steel 0" to 2 -1/4" 1 or 2 hours W -J -1067 FS One EMT Conduit 4" EMT Wall PVC CPVC 2" either 1/4" to 11/16" 1 or 2 hours W -J -2108 FS One UUcUL SYSTEM NO. W -L -1054 METAL PIPE THROUGH 1 -HR. OR 2 -HR. GYPSUM WALL ASSEMBLY F- RATING = 1-HR. OR 2 -HR. T- RATING = 0 -HR. L- RATING AT AMBIENT = LESS THAN 1 CFM /SQ. FT. L- RATING AT 400 °F = 4 CFM /SQ. FT. FRONT VIEW SECTION A -A 0 A -0— o low A � � 0 1. GYPSUM WALL ASSEMBLY (UUULC CLASSIFIED 0300 OR U400 SERIES) (1 -HR. OR 2 -HR. FIRE - RATING) (2 -HR. SHOWN). 2. (NOT SHOWN). WOOD STUDS TO CONSIST OF NOMINAL 2" x 4" LUMBER. STEEL STUDS TO BE MINIMUM 2 -1/2" WIDE. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 30" DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER). B. MAXIMUM 30" DIAMETER CAST IRON PIPE. C. MAXIMUM 6" NOMINAL DIAMETER COPPER PIPE. D. MAXIMUM 6" NOMINAL DIAMETER STEEL CONDUIT. E. MAXIMUM 4" NOMINAL DIAMETER EMT. 4. MINIMUM 5/8" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT. 5. MINIMUM 112" BEAD HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT AT POINT OF CONTACT. NOTES : 1. MAXIMUM DIAMETER OF OPENING : A. 32 -114" FOR STEEL STUD WALLS. B. 14 -1/2" FOR WOOD STUD WALLS. 2. ANNULAR SPACE = MINIMUM 0 ", MAXIMUM 2 -1/4 ". 3. PIPE MAY BE INSTALLED WITH CONTINUOUS POINT OF CONTACT. 4. PIPE MAY BE INSTALLED AT AN ANGLE NOT GREATER THAN 45° FROM PERPENDICULAR. ® Sheet 1 of 1 Drawing No. LiP I L�i HILTI, Inc. Scale 713r=1" WL FIRESTOP SYSTEMS Tulsa Oklahoma USA (918) 252-6000 Date Nov. 6, 2002 1054q Saving Lives through Innovation and Education MIL.TI Product Information P roduct description FS -ONE p • Intumescent (expands when exposed to fire) firestop sealant FS -ONE High Performance that helps protect combustible and non - combustible penetra- Technical Data [ions for up to 4 hours fire rating At 73 °F (23 °C) and 50% relative humidity Intumescent Firestop Product features Chemical basis Sealant • Smoke, gas and water resistant after material has cured Water -based intumescent acrylic dispersion • Contains no halogen, solvents or asbestos Density • High fire rating properties Approx. 1.5 q /cm' • Water based, easy to clean Color f ,I§ - ..< Red Areas of application Wcrljng time • Steel, copper and EMT pipes Approx. 20 -30 min. ., 1 • Insulated steel and copper pipes Curing time r i `\ • Cable bundles Approx. 4 mm / 3 days � - I 7.4 • Closed or vented plastic pipes Shore A Hardness system Advantage / Customer Benefits • HVAC penetrations APProx. 35 • Protects most typical firestop For use with Movement capability penetration applications Approx. 5% • Concrete, masonry, drywall and wood floor assemblies • Easy to work with and fast cleanup • Wall and floor assemblies rated up to 4 hours Approx um scent (2Activation 5 • Can be painted • Single component systems available Examples Expansion rate (unrestricted): s LEEDTM' requirements fa indoor construction • Sealing around plastic pipe penetrations in fire rated Up to 3 -5 times original volume • Meets LEE mental quality credit 4.1 Low construction Temperature resistance (cured) Emitting Materials, Sealants and • Sealing around combustible and non- combustible —40 °F to 212 °F (-40 °C to 100 °C) Adhesives and 4.2 Paints and Coatings penetrations in fire rated construction Application temperature 41°F to 104 °F (5 °C to 40 °C) c� Installation instructions for FS-ONE Surface burning characteristics n Opening Notice about approvals (ASTM E 84 -96) o 1. Clean the opening. Surfaces to which FS -ONE will be • Check that the penetration has been sealed according to Florin Spread: 0 applied should be cleaned of loose debris, dirt, oil, the specified drawing in the UL Fire Resistance Directory Smoke Development: 5 - moisture, frost and wax. Structures supporting or Hilti Firestop Manual. For further advice, please Sound transmission classification o penetrating items must be installed in compliance with contact Hilti customer service. Refer to Hilti product (ASTM E 90 -99) 56 ct local building and electrical standards. literature and UL fire resistance directory for specific application details. Approvals vv) Application of firestop sealant ICBO (Irtemational Conference of 2. Install the prescribed backfilling material type and depth Not for use... Building Officials) to obtain the desired rating (if required). Leave sufficient • High movement expansion joints Report No. 5071 depth for applying FS -ONE. • Underwater California State Fire Marshal 3. Application of firestop sealant: Apply FS -ONE to the • On materials where oil, plasticizers or solvents may Listing No. 4485- 1200:108 required depth in order to obtain the desired fire rating. bleed i.e. impregnated wood, oil based seals, green or of New York Make sure FS -ONE contacts all surfaces to provide partially vulcanized rubber MEA 326 -96 -M maximum adhesion. For application of FS -ONE use a • In any penetration other than those specifically standard caulking gun, foil pack gun, bulk Bader and described in this manual or the test reports -, bulk gun. With FS -ONE buckets, Graco type sealant Safety prT�cawens Tested in accordance with pumps may be used. (Contact pump manufacturer for • Before handling, read the product and Material Safety • UL 1479 „ proper selection). Data Sheet for detailed use and health information • ASTM E 814 4. Smoothing of firestop sealant: To complete the seal, tool • Keep out of reach of children • ASTM E 84 '= immediately to give a smooth appearance. Excess • Wear suitable gloves and eye protection sealant, prior to curing, can be cleaned away from Storage Internationally tested and approved adjacent surfaces and tools with water. • Store only in the original packaging in a location '''' as. nu.vaooaairr►wrr�u 5. Leave completed seal undisturbed for 48 hours. protected from moisture at temperatures between i NTM TM STOP SYSTEM 6. For maintenance reasons, a penetration seal could be 40°F (5 °C) and 86 °F (30 °C) C ° ex SEE u rw OIRECTORY permanently marked with an identification plate. In such • Observe expiration date on the packaging 86'" a case, mark the identification plate and fasten it in a visible position next to the seal. 4 <> — �avnoven .. 411 :7 '11 � 1. (lean opening. 2. Pack mineral 3. Apply FS -ONE. 4. Smooth FS -ONE. 5. Leare 6. Fasten !dental- r wool (If regwirec) seal for ca tion plate (N 48 . ire d• © latest product information : rx 1 All H — www.us.hilti.com : 1 4 .k�* [ oi information see page: ,. 34 1. Can opening. 2. Pack mineral 3. Apply FS -ONE. 4. Smooth FS -ONE. 5. Lave �tr�yeted 6. Fasten lde tilica- wnol. pr required) seal urrdis la don plate (d Saving Lives through innovation & education I Hilti Firestop Guide gitt2006 I 1 1 79 -8000 1 www.us.hilti.com lM1`•g • 17 Mater ;)aliety iJdit1 . :F1,,; 11411LIIIIITII MSDS No.: 259 Revision No.: 010 Revision Date: 08/17/04 Page: 1 of 2 Product identifier: FS -ONE High Performance Intumescent Firestop Sealant Description: One -part acrylic -based sealant Supplier: Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121 Emergency # (Chem - Trec.): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) INGREDIENTS AND EXPOSURE LIMITS Ingredients: CAS Number: PEL: TLV: STEL: Polyacrylate dispersion Mixture NE NE Calcium carbonate NE m 001317 -65 -3 Zinc borate 5 mg /m (I) 10 mg/m' (T) NE 138265 -88 -0 NE NE NE Ammonium polyphosphate 068333 -79 -9 NE NE Talc NE 014807 -96 -6 20 mppcf 2 mg /m' NE Expandable graphite 012777 -87 -6 5 mg /m' (T) 2 mg /m' (1) NE Ethylene glycol 000107 -21 -1 ........ __.._ NE C:100 mg /m' (A) NE Polybutene y_ 009003 -29 -6 NE NE NE Iron oxide 001309 -37 -1 10 mg /m' 5 mg/m) Glass filament 065997 -17 -3 NE 5 mg /m ' (1) NE NE Silicon dioxide ,, 014808 -60 -7 0.05 mg/m 3 (T) 0.1 mg /m' (T) NE Water 007732 -18 -5 NE NE NE Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. C = Ceiling. STEL = Short Term Exposure Limit. NE = None Established. NA = Not Applicable. (1) indicates as total dust ". (R) indicates "as respirable fraction ". .. (A) indicates "as an aerosol ". mppcf = million particles per cubic foot. PHYSICAL DATA Appearance: Red paste. Odor: Odorless. Vapor Density: (air = 1) Not determined. Vapor Pressure: 23mbar @ 20C / 68F Boiling Point: 9 Not applicable. VOC Content: 75.0 g /L. Evaporation Rate: Not applicable. Solubility in Water: Soluble. Specific Gravity: 1.5 pH: Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point Non-flammable. Flammable Limits: Not applicable. Extinguishing Media Not applicable Use extinguishing media as appropriate for surrounding fire. Special Fire Fighting Procedures. None known. Use a self-contained breathing apparatus when fighting fires involving chemicals. Unusual Fire and Explosion Hazards: None known. Thermal decomposition products can be formed such as oxides of carbon, sulfur and phospho- rous. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. Incompatibility: Strong acids, peroxides, and oxidizing agents. o Decomposition Products: Thermal decomposition can yield CO and CO2. Conditions to Avoid: None known. — HEALTH HAZARD DATA =0 Known Hazards: None known. ........... E, Signs and Symptoms of Exposure: Possibly irritating upon contact with the eyes or upon repeated contact with the skin. Medical Conditions Aggravated by Exposure: Eye and skin conditions. Routes of Exposure: Dermal. .-- Carcinogenicity: 09 ty IARC classifies crystalline silica (quartz sand) as Group I based upon evidence among workers in industries s where there has been long -term and chronic exposure (via inhalation) to silica dust; e.g. mining, quarry, stone W crushing, refractory brick and pottery workers. This product does not pose a dust hazard; therefore, this clas- sification is not relevant. Based upon the nature and intended use of this product, it does not pose an increased cancer risk to workers. 454 ■/L.Ti • Saving Lives through innovation & education I Hilti Firestop Guide 2005 -2006 1 1 -800- 879 -8000 1 www.us.hilti.com • 11•141„T, Material Safety Data Sheet MSDS No.: 259 Revision No.: 010 Revision Date: 08/17/04 Page: 2 of 2 EMERGENCY AND FIRST AID PROCEDURES Eyes: Immediately flush with plenty of water. Call a physician if symptoms occur. Skin: Immediately wipe off material and wash with soap and water. Material can adhere to the skin. If material has adhered to the skin, use an abrasive containing hand cleaner. If material does not come off, buff with a pumice stone. Inhalation: Move victim to fresh air if discomfort develops. Call a physician if symptoms persist. Ingestion: Seek medical attention. Do not induce vomiting unless directed by a physician. If a large quantity was ingest- ed, give 1 to 2 glasses of water to dilute. Never give anything by mouth to an unconscious person. Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General (natural or mechanically induced fresh air movements), Eye Protection: Not required, however, safety glasses should be wom in most industrial settings. Skin Protection: Avoid skin contact. Cloth gloves are suitable for hand protection. Respiratory Protection: None normally required. Where ventilation is inadequate to control vapors, use a NIOSHapproved respirator with organic vapor cartridges. Never enter a confined space without an appropriate air - supplied respirator. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Precautions: Store in a cool, dry area preferably between 40o and 77o F. Keep from freezing. Do not store in direct sunlight. Avoid contact with the eyes or skin. Practice good hygiene; i.e. always wash thoroughly after handling and before eating or smoking. For industrial use only. Keep out of reach of children. Follow label /use instructions. Spill Procedures: Immediately wipe away spilled material before it hardens. Place in a container for proper disposal in accor- dance with all applicable local, state, or federal requirements. REGULATORY INFORMATION Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE 8 ......................... _... DOT Shipping Name: Not regulated. IATA / ICAO Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory. SARA Title III, Section 313: This product contains < 3% ethylene glycol (CAS 107 -21 -1) and < 15% zinc borate (re: zinc compounds) which are subject to reporting under Section 313 of SARA Title III (40 CFR Part 372). EPA Waste Code(s): Not regulated by EPA as a hazardous waste. Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service: 1 800 879 8000 Health / Safety: 1 800 879 6000 Jerry Metcalf (x6704) Emergency # (Chem - Trec): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) v, The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind n expressed or implied is made with respect to the information provided. • --1 m • --1 D Saving Lives through innovation & education I Hilti Firestop Guide 2005 -2006 I 1 - 800 - 879 - 8000 I www.us.hilti.com 455 Certificate at Com trance Certificate Number 20060214- R13240E Page 1 of 1 Report Reference 2006 February 14 Issue Date 2006 February 14 Underwriters L Laboratories Inc. Issued to: Hilti, Inc. 5400 S 122ND East Ave Tulsa, OK 74146 USA This is to certify that Fill, Void or Cavity Materials representative samples of FS -ONE Have been investigated by Underwriters Laboratories Inc.® in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: ANSI/UL 1479, ANSI/UL 2079, CAN/ULC -S 115 -05 Additional Information: FS -ONE Sealant for use in Joint Systems and FS -ONE for use in Through - Penetration Firestop Systems as currently described in the UL Fire Resistance Directory. Only those products bearing the UL Classification Mark should be considered as being covered by UL's Classification and Follow -Up Service. The UL Classification Mark includes: UL in a circle symbol: g with the word "CLASSIFIED" (as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL's evaluation of the product; and, the product category name (product identity) as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product Issued byC� l�� Reviewed by: ouloute Christopher on Underwriters Laboratories Inc. Underwriters ratories Inc. Thermatiher NONCOWBUSTIBLE ECONOVALAL VERSATILE APPLICATION VARIETY OF USES NUNASBESTOS For efficient insulation offering condensation control, acoustical correction and thermal values Variety of Forms, Versatile Uses Packing Wool Thermafiber Bulk Wool offers a choice of granulated wool, Similar to Thermafiber Granulated Wool, but designed for packing wool, spray wool, cryogenic and high - performance hand packing rather than pouring or mixing. Recommended (HP) wool. for heat control In boilers, tanks, expansion Joints and ovens where the shape of the insulation cavity precludes the use of Granulated Wool felt insulation. Thermafiber Granulated Wool consists of mineral fibers industrial Spray Wool formed into small nodules or pellets. Abers are air- cleaned and treated with dust - collecting oil. Can be used for hand- A high - quality mineral fiber Insulation, Thermafiber Spray poured applications or mixed with other materials as a filler Wool is lightly treated with mineral oil and produced in pellet in insulating cements and foundry molds. form for pneumatic spray application. Adhesives or binders, added by the applicator, prepare this product for spray Industrial Blowing Wool application. Used for fire resistance, condensation control, acoustical correction and thermal Insulation when mixed Thermafiber Granulated Wool is also available for pneumatic with binder. Color uniformity cannot be maintained due to application. variables in raw materials and types of adhesives used. Organic treatment content is less than 1% by weight. Fiber melt point exceeds 2000 °F per ASTM C24. Cryogenic Wool Granulated mineral fiber formulated specifically with an oil content (L01) of Tess than 0.2% by weight. Used for thermal insulation for cryogenic tanks such as liquid oxygen. High- Performance (HP) Wool ry Dark fiber formed In nodules tor hot surface temperatures - ,r up to 1900 °F Improved performance: less shrinkage and better thermal conductivity for cements, foundry molds and II boards, and fireplace chimney applications. Nonadsorbent, Corrosion- Resistant Adsorbs Tess than 2% moisture. Does not corrode steel or aluminum as tested per Federal Specification HH-I-558B. Easily Applied Thermafiber Industrial Bulk Wool applies easily by hand or with fast pneumatic application. Fits quicky into grooves, slots and other awkward or hard -to -reach openings. herritiffi it . . :'.4:;r: Viiiiiii • , icAcorbosr,,LE t (7, "IC[, ltfi. ..,HiIrUFp,r, t.0'068ESIUS Physical Properties PhySICai Data Instilled II- helot —b0 • Ia.Tr. se. • ft. •F" Recommended max. Product density temp. set std —•F 30-I6. Ai. wt. Avg. wt. designation pdre 78•F 300•F 500•F (inclosed panel) bagp. R. Ib.Asg. lb./bale Industrial Bulk Wad (Density varies with paddng pressure- -three random densities shown.) Granulated 1 f 4.0 .27 .44 .71 800 30 850-750 Packing I 1 8.0 .28 .38 .56 1,200 2.8 30 650-750 Industrial Spray 1 f 4.0 .27 NA NA NA 2.8 30' 650 -750 Wool l 8.0 .28 Cryogenic Wool .27 NA NA 1,600 NA 30 NA High Perfonmrrce 700•F 10007 - (HP) Wool 14.0 NA .69 .98 1,900 2.8 30 650.750 (1) Sample of belch ed4atsied denials. prhtnYY1 cost for pealp spur towel d rroAbe seploterr (2) bull S rain tsmpwatea. (8) Ammo Pim ha any se lb. big welts wool Surface Burning Characteristics Sound Data --Nola Reduction Coefficient (NRC)• Flame spread 0, smoke developed 5 per ASTM E84 as tested Bead Carder � eeyr (hz) Yrodud Thickness 250 500 1000 2000 MRC by Underwriters Laboratories Inc. (UL). Noncombustible as Industrial 2" .66 .85 .83 .87 50 defined by NFPA and National Fire Code when tested per Spray Wool 4" — i9 — 80 63 84 61 _ ASTM E136. 'The addition or any other materials, other than Tnrnwwsace Spray Wool, and Muir elect on • performance being uncontrolled by Thermallber, are not warranted Dy Thennatber Specification Compliance Thermafiber Industrial Blowing Wool meets ASTM C764. _ Availability - Thermafiber 10 Granulated Wool meets U.S. Coast Guard Wabedl, IN Tacoma, WA Spring Hope, NC Nolenvllle, TX Specification 164.009/169/0. _ _ Gremdeted x x - x x /10 Granulated x Paddng x ' x x Spray x x x High Performance x Cryogenic x - x The eraxrnslan petard Amin For further bnDnmlion on thew and other in monism with or tome printed ba1c- shah es hued oxypn area. ern Cryoemlc awaurrru bead wows. uwmas producer, Including noro0rtdrd alms, eons. Oar NOW MN be awes* Inaba to wool sty Cryopwdc wool les a mad - abr0adryASTw aararemndud caravel Thennalbu al ties sae offices: d edicaant al delecew goods. Any dint man oil content of 02% by weight. other mho*. The agues w wy to normal Thome, lrA Mt 42114127 Oh read 10 as *OM delobsy sib Me wool products nay hoes sealer o1 con - n enuecl eery wbiba Theperen using wabesb, IN (Min x42371 eroded contained herein shit be deemed tents, each an creme en ermloalon hu- t* prodxt owl den de beeeabey br Nelaaellts, IX (111) WNW 'abed saws nude le wales tow within aN wan Wood to aides* nb- e praArrapplosion Steno Nape, MC (000) a4as4 01 Iny (30) dam et the dune sum Sped delF emcee Bacon cond0lan of eselestbu SAFETY MITI Mcrae good misty and Ne110E In a sent eludes b table for N sea a remonaby should sae ten and use re beyond 0 control, . Inert* unglue prudent during wr ;edit butted, Incidental r cone- 7hermdbr f e not arse responsibility la landing and instating d M womb are °r explosion . pasc d r upes Yc1uArM, ba not wrorea systems. lave memory preeeseons and iodine or anticipated poets or mouse, wren appropriate earwax protective wear or not such drape so damn In addiunerd is needed. Reed "deem contract tort gn4rAnp neglares), waren- ewy ems tars and relied Meneure on by strict Ia011b or Whines'. In addition, product baron speak: don indoor sue sal not be bible for e y 0051511010 • Ingestion. or caused by ap llcaion of sees Goods not - wino*: For cabin mummy appricrbne - AMERICAN ROCKWOOLV aaa 3711 West M01 Street • Wabash, IN 48992 -8687 • Phone (888) TFIBER1 (834 -2371) • Material Safety Data Sheet 1 • MSDS No.: 270 Revision No.: 003 Revision Date: 06/18/03 Page: 1 of 2 Product name: Mineral wool Description: Synthetic vitreous fiber Supplier: Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121 Emergency # (Chem-Trec.): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) INGREDIENTS AND EXPOSURE LIMITS - Ingredients: CAS Number: P EL: TLV: STEL: Slag wool fiber 65997 -17 -3 NE 1 fiber / cc NE Phenolic resin 09003 -35 -4 NE NE NE Polyvinyl alcohol 09002 -89 -5 NE NE NE Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. STEL = Short Term Exposure Limit. NE = None Established. NA = Not Applicable. PHYSICAL DATA Appearance: 2' x 4' x 4" sheets. Odor: Negligible. Boiling Point: Not applicable. Vapor Pressure Not applicable. Melting Point: Approx. 2400° F VOC Content: Not applicable. Evaporation Rate: Not applicable. Solubility in Water: Insoluble. - pH: Not applicable. Specific Gravity: Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Not applicable. Flammable Limits: Not applicable. • Extinguishing Media: As appropriate for surrounding fire; material does not bum. Special Fire Fighting Procedures: Soak cartons to help prevent the spread of fire. Use a self - contained breathing apparatus when fighting fires involving chemicals. Unusual Fire and Explosion Hazards: None known. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. Incompatibility: Strong acids. Hazardous Decomposition Products: Thermal decomposition products can be formed at temperatures exceeding 2000° F. Thermal decomposition can yield CO and CO Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: Acute: Eye, skin and respiratory irritation. Chronic: Respiratory impairment. Routes of Exposure: Inhalation, Dermal. Signs and Symptoms of Exposure: Eyes: Mechanical irritation. Skin: Itching, irritation. Inhalation: Nose, throat and upper respiratory tract irritation. Carcnogenicity: Slag wool has been classified by the IARC as Group 3 — Unclassifiable as to Carcinogenicity in Humans Medical Conditions Eye, skin, and respiratory conditions. Aggravated by Exposure: W H C7 480 •I`Tf11 ' Saving Lives through innovation & education I Hilti Firestop Guide 2005 -2006 I 1 -800 -879 -8000 I www.us.hilti.com �xt MSDS No` 270 Revision No.. 003 Revision Date: 06/18/03 Page: 2 of 2 EMERGENCY AND FIRST AID PROCEDURES Eyes: Flush with plenty of water while holding eyelids apart. Avoid rubbing the eyes as mechanical abrasions can occur. Call a physician if symptoms persist. Skin: Wash with soap and water. Launder clothing before reuse. Inhalation: Move to fresh air. ........................... Ingestion: No ill effects expected. Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. - CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General (natural or mechanically induced fresh air movements). Eye Protection: Safety goggles recommended to prevent particulates from irritating the eyes. Skin Protection: Cloth gloves and long sleeves to protect skin from irritating fibers. Respiratory Protection: Use local exhaust and /or a NIOSH- approved dust respirator when air movement is inadequate to control dusts / fibers below recommended exposure levels. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Precautions: Avoid generating dusts. Local exhaust may be required to control dusts if power tools are used for cutting / trimming, Wear appropriate personal protective equipment. Store away from moisture; keep dry. Spill Procedures: Not applicable. REGULATORY INFORMATION Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE B (Gloves, Goggles) DOT Shipping Name: Not regulated. IATA / ICAO Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory. SARA Tile III, Section 313: This product does not contain any toxic chemicals which are subject to reporting under Section 313 of SARA Title III (40 CFR Part 372). EPA Waste Code(s): Not regulated by EPA as a hazardous waste. Waste Disposal Methods: sP Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service: 1 800 879 8000 Health / Safety: 1 800 879 6000 Jerry Metcalf (x6704) Emergency # (Chem- Trec): 1 800 424 9300 (USA PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. Saving Lives through innovation & education I Hilti Firestop Guide 2005 -2006 I 1 - 879 - 8000 I www.us.hilti.com !041I`TI • 481 ° tar Anvil Steel Pipe Nipples - Submittal Sheet (111r ANVIL Anvil Steel Pipe Nipples C)4>@ APPROVED AnvilStarTh" offers a variety of Steel Pipe Nipples For the fire protection industry. Anvil's Steel Pipe Nipples are manufactured in accordance with ASTM Standard Specification _� " A733- Welded and seamless carbon steel and stainless carbon steel and stainless steel pipe nipples. Materials include black and hot- dipped galvanized finishes. Anvil° manufac- tures a wide range of stock pipe nipples in /a" diameter through 8" diameter close through 72" inch length in half -inch increments. We also offer standard nipple packs ranging from one each (close to 6 ") and standard six packs which offer multiple counts of each. Cartons are packed with handles for easy carrying. PROJECT INFORMATION: APPROVAL STAI.IP: Project: undefined Date: undefined I Phone: undefined Architect / Engineer: undefined Contractor: undefined Address: undefined Notes 1: undefined Notes 2: undefined 3/05 - 104 For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative AliIwtLStar Anvil Cast Iron Product Submittal Sheet 4Z ANVIL Anvil Cast Iron Threaded and Flanged Fittings C) C APPROVED AnvilStarTM offers the most complete line of Cast Iron and Malleable Iron Threaded Fittings in the industry. Our versatile range of fittings is designed to provide dependable, fire-rated service. Cast Iron Threaded Fittings, are manu- factured in accordance with ASME B16.4. They are UL listed and FM Approved and are available in sizes I/4" NPS through 12" NPS. Project: undefmed Date: undefmed I Phone: undefined Architect / Engineer: undefined Contractor: undefined Address: undefined Notes 1: undefined Notes 2: undefined 3/05 - 100 For the latest UUULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative FIG. 92 Beam Clamps ANV Star Fire Product Division a AnN° International O r ) AiwiL Universal C -type Clamp (Standard Throat) Submittal Sheet SIZE RANGE: 3 A1 and 1 /2" MATERIAL: Ductile iron, hardened steel cup point set screw and locknut FINISH: Plain or Galvanized SERVICE: Recommended for use under rod installations with bar joist lype construction, or for attachment to the top or bottom flange of strudurd shapes where the vertical hanger rod is required to be offset from the edge of the flange and where the thickness of joist or flange does not exceed 3 /4 ". f - APPROVALS: Complies with Federal Specification A- A -1192A (Type 19 & 23), WW-H- 171 -E (Type 23) and MSS -SP -69 (Type 19 & 23). UL, ULC Listed and FM Approved. HOW TO SIZE: Size of clomp is determined by size of rod to be used INSTALLATION: Follow recommended set screw toque values per MSS -$P -69 (See table on page PF 212) \/ \% FEATURES: • They may be attached to horizontal flanges of structural members in either the top beam or bottom beam positions. • Secured in place by a cup-pointed Set Screw tightened ogainst the flange. A Jam Nut is provided for tightening the Set Screw against the Body Casting. • Thru tapping of the body casting permits extended adjustment of the threaded rod. + N c — E 1' F • Can be used with Fig 89X retaining dip For seismic applications. G 1_ p T i BE EXPOSED 0 ia. '... . .... CA 118t(li BODY , j1 1111 JAM - NUT SET SCREW FIG. 92 Rod Size Set Screw Aka Loads IN A Size T Bottom Weight D E F G H i� _. is F r a 'I '� i : t a a t i K ° f r `' t• .� ''srPe "q'p 'sA ,® t;'�,.;�,a.��a�,1.,.a;}'^ ,.�... N,�a Y,.� a.�ac..,.;2�'»4.,,.. 3 3„ 500 250 0.34 1 1 'A6 1 3/11 1/2 I / 1 h 950 160 0.63 1% 113 Ifs 1 3 /16 2 • Maximum temperature of 450° F PROJECT INFORMATION: APPROVAL STAMP: Project: Date: I Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Refer to the Pipe Hanger Catalog for Additional Parts available on Anvil's Web Site www.anvilintl.com Anvils Pipe Hangers & Supports For the latest UUULC Listed and FM Approved pressure ratings, versus pipe schedule, ("ir �L REV. 03.03.06009 go to www.anvllstar.com or contact your local AnvilStar representative FIG 69 Pipe Rings 43O f Mve• International Adjustable z)AMnL j table Swivel Ring, Tapped Per NFPA Standard Submittal Sheet SIZE RANGE: I/2* through 8' MATERIAL: Carbon steel ih FINISH: Galvanized SERVICE: Recommended for suspension of non - insulated stationary pipe line. MAXIMUM TEMPERATURE: 650° F APPROVALS: Complies with Federal Specification A- A -1192A (Type 10), WW-H -171 -E (Type 10) and MSS -SP -69 (Type 10). UL Listed and FM Approved (Sizes 3 /4' - 8'). FEATURES: • Threads are countersunk so that they cannot become burred or damaged. • Knurled swivel nut provides vertical adjustment after piping is in place. 0 • Captured swivel nut in the le through 3' sizes. id Pipe Size Max Load Weight Rod Size A B C F / 1 \ F.. : 1/2 u. . L. 0.1 0 ... u.. , ,.x. 1 2 1 F C B 3/4 0.10 23/4 17 115 1 0.10 2 1 1 /,' 300 / q. 1 0.10 2 1 I 7A I + 11/2 0.10 3 4 23/4 1 \. 2 0.11 3 2 1 21/ 525 0.20 4 2 1 3 0.20 3 2 1 4 650 0.30 4 3 1 5 0.54 5 4 6 1,000 0.65 1/2 6 5 2 8 1.00 8 7 2 Project: Date: I Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Refer to the Pipe Hanger Catalog for Additional Parts available on Anvil's Web Site www.anvilintl.com Anvil® Pipe Hangers & Supports For the latest ULIULC Listed and FM Approved pressure ratings, versus pipe schedule, Z REV 03.03.06002 go to www.anvllstar.com or contact your local AnvilStar representative HANGER RODS EmP i xt,siVIL Fig. 146 Continuous Threaded Rod Size Range: 1 /4' through 11/2' Stocked in six, ten, and twelve foot lengths. Other even foot lengths can be furnished to order. Material: Carbon steel; rod threaded complete length. Finish: O Plain or O Galvanized. Maximum Temperature: 650° F. Ordering: Specify rod diameter and length, figure number, name and finish. — Fig. 146: Loads (Ibs) • Weights (Ibs) Dimensions (in) — Rod Threads Max Load — `— Weight — Size A per Inch 650° F per Ft. 1 /4 20 240 , 0.12 r Length __..._ _....._.. . .............__.... 3 /e 16 730 0.30 MalliteNIMINEINIIMMBIONMI 1/2 13 1,350 1 0.53 /e 11 2,160 I 0.84 A 3/4 10 3,230 1....._.._.........._._- 1.20 ...................... 7 /e 9 4,480 -- .-----8--- - — i - -- — 1.7 0 - - - - -- 1 5,900 2.30 1 7 9,500 3.60 1 6 13,800 5.10 Note: Other rod sizes available upon request. • ----- Class 2 fit is available upon request. ) 6 \ C/(! I ' 1 �� j Pipe Hanger Submittal Sheet Project: Architect / Engineer: Approval Stamp: Date: Phone: Contractor: Address: Notes 1: Notes 2: ScheduIe-1�®/Scheie..4O Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule -10 /Schedule -40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule -10 /Schedule -40 gives you the extra quality assurance you demand. Our Sch -10 (11/4"- 8 ") pipe and Sch-40 (1 "- 2'/ ") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Sch -40 Specifications Schedule-10/Schedule-40 product can be NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Lift (21') WULift (24') WV.ift (25') "hot - alvanized to meet FM In; mm In; mm Lbs/Ft; Kg/m Lbs/Ft; Kg /m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1?'" g requirements for dry systems in ,®„-,� 1" 1.049 1.680 2.05 70 2,470 2,822 2,940 accordance with the zinc coating 25 26.6 2.5 3.05 70 1,120 1,280 1,334 specifications of ASTM A - 123. 1'/4" 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 Superior Coating 1' /s" 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 Our advanced formula mill coating of- 2" 2.067 3.650 5.13 30 2,300 2,628 2,738 fers a clean, durable surface. It is also 50 52.5 5.4 7.63 30 1,043 1,192 1,242 paint -ready for custom color applications 21/2 2.469 5.790 7.86 19 2,310 2,640 2,750 without special preparation. 65 62.7 8.6 11.73 19 1,048 1,197 1,247 The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe Sch-10 Specifications products up to 4.5000" in diameter is coated with our new Antibacterial For- 'S Nominal I.D. Wt. Wt. (H20 Filled) Pas/ IAN/Lift (21') WtWLIft (24') 1 ift (25') mula, "ABF ". In scientific laboratory In; , In; mm Lbs/Ft; Kg /m Lbs/Ft; Kg /m Lift Lbs; Kg Lbs; Kg Lbs; Kg test, ABS proved to have superior resis- 1" 1.097 1.400 1.81 91 2,675 3,0 3,185 tance to microbial colonization of pipe 25 .9 2.1 2.70 91 1,213 ,385 1,445 walls, thereby delaying or possibly pre- 11/4' 1.4 : 1.810 2.52 61 2,319 2,664 2,760 venting the onset of Microbiologically 32 36.6 2.7 3.75 61 1,0 1,208 1,252 Influenced corrosion (MIC) when the 11" 1.682 I80 3.04 61 ,664 3,045 3,172 First Sprinkler System is first installed. 40 42.7 3�N 4.52 61 1,208 1,381 1,439 American Made 2" 2.157 2.640 4.22 7 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 Meets "Buy American" requirement 2'/' 2.635 3.530 30 2,224 2,542 2,648 and is available through distributors in 65 66.9 5.3 ;,77 \ , 30 1,009 1,153 1,201 the USA, Canada and Mexico. 3' 3.260 4.330 7.94 '''1. 1,728 1,975 2,057 Specifications & Approvals 80 82.8 6.4 11.82 1 • 784 896 933 4" 4.260 5 0 11.78 19 , 38 2,558 2,665 Schedule -10 /Schedule -40 pipe are in 90 108.2 8.3 17.53 19 1,0 1,160 1,209 compliance with the following: 5' 5.295 7.77 17.33 10 1,632 1,865 1,943 125 13', . 11.56 25.80 10 740 ' . 6 881 ASTM A - 135, and NFPA 13. Both pipe 6' :'357 9.290 23.03 10 1,951 2,23 N 2,322 products have a working pressure rating 150 / 1 6 1.5 13.8 34.27 10 885 1,012 1,053 of 300 psi maximum and also meet the 87 8.249 16.490 40.15 7 2,424 2,770 ,885 stringent requirement for the following , •O 209.5 24.5 59.75 7 1,100 1,256 1, 4 9 tests: • Welded Outlets el 41 /: 0 • Hydrostatic Pressure • Side Wall Rupture Listed Approved Listed • Vibration Test ti1CO /F /ow Contro/ allied 16100 S. Lathrop • Harvey, IL 60426 Customer Service: T 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882 -5543 TUBE 8 CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S5 - 3 t c0 oa a c� Z SPRINKLER HEAD LEGEND SYY QTY TYPE FINISH TEMP K WT MFO. MODEL j SIN j DESCRIPTION MAX COVERAGE J EX . EXIST UPRIGHT BRASS 155 8.00 3/4' EXISTING EXPOSED / 130 SO-FT. (THROUGHOUT) 0 11 PENDENT WHITE 155 8.00 314' VIKING M VK -352 RECESSED 1' DROP (E -1 ESCUTCH) / 130 SQ.FT. 11 - TOTAL QUANTITY FOR THIS TENANT. ALL HEADS ARE QUICK RESPONSE. ti TO 3PPJNKLER 1 4 Aft 1 LIA El 0 l� (3ROOVECHEgfVN.4E WALL MOUNT FUC —X PIPE DPNN TO EXTERIOR ON SPLASH BLOCK"O\ EXISTING RISER DETAIL NOT TO SCALE FLOW SWff0i -- ----`"" W-�: l L INSPECTOR'S TEST ADRAAI � chtacvavEwiDAM vxve AND GWEs — CONTROL VALVE wi 4TAMRSWIT'CH N SUPPLY PIPE FINISHED FLOOR A GRAPHIC SCALE 0 4 8 16 (IN FEET) SCALE 1/8' . 1' -0' `../ r Lom 1 A Pm" L.... 1--m. • --01 i v ■ `.. 8- ■ In NOT TO SCALE 4 i to i REMOVE EXISnNG UPRIGHT SPRINKLER. BEAM CLAMP NEW I ARMOVER NEW I 90 ELL I ( ARMOVERS GREATER THAN (TYPICAL) I I 24' SHALL HAVE HANGER. ALL THREAD ROD (A.T.R.) £?QSIING 3/$ A.T.R. 4 AND SMALLER I SPRIG EXISTING 2' I I BRANCHUNE N NEW In DROP I x 3/4' R. C. 2x4 ACT CEILING QUART SWING; NOT TO SCALE u7& - ;Spd this review of plms s b(am' i3 8 C r y re�r : ry to assist the conUa V in r *&e sa codes. 'fhis ravie i not int k -- to tP, a final aWoval of the s��i�itt.'�1 flans. It is the c'Q0'q- :liar's 9, resrfity to enre �3�t t�`�e plus a���n c lv'—to Car planca wtla) al o4w-y-vaiNe NFPA codtls a �,c l 0(dinarecras. In b3 evult that file her exa eta k1sp�:r'.�an re rin. "- aeas of rxx: •_ia1 IFi •e, it �hatl b%a cotlu xWs s res�� s it ity, ti~ 4t Sa'a e a rsa t•� vm llw-a aeas in coillp` -ame. 4 12 aw1rr::. s ne reins l fit`y x y�tr ct�a�s f �Ipia � Ira i;i clurl-p'i p lfl ,V, ,:, fIFPA Cc40S WJ Or ..J ( ik ?, SUBMI OED &AN(S) Iii VE Br-N REVIEWED By ZEI'HyRHILL• -'t ' SHAL'S 01-ICE 60 ►Date: _-- ao Revizw.r: 7. FIRE PROTECTION PLAN SCALE: 1/8' = 1' -0' ER POINT JOINT DETAI 11 IL OPEN WEB BAR JOIST FOR i THROUGH 4' HHANNG TO TOP CHORD OF JOIST ONLY BRANCHLINES MAY BE HUNG FROM BOTTOM CHORD OF JOIST. BEAM CLAMP HANGER #1 DE NOT i0 SCALE ENERAL NOTES: SPRINKLER SYSTEM SHALL COMPLY WITH THE-2002 EDITION OF NFPA 13. SPRINKLER HEADS SHALL BE ORIFICE, STYLE AND TEMPERATURE TO MEET CODE. REFER TO SPRINKLER HEAD LEGEND THIS SHEET. SYSTEM TEST SHAD. BE WITNESSED BY CITY OF ZEPHYRHILLS FIRE MARSHAL PRIOR TO ANY PORTION BEING CONCEALED. GIVE 48 HOURS NOTICE. HANGERS TO BE PER DETAILS ON THIS SHEET. HANGERS SHALL BE SPACED IN ACCORDANCE WITH 2002 NFPA 13 REQUIREMENTS. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES PRIOR TO FABRICATION. 2' PIPING AND LARGER SHALL BE GROOVED SCHEDULE 10 WITH THREAD -O -LETS OR GROOVE --O -LETS. 1" PIPING SHALL BE THREADED SCHEDULE 40. 2' GRIDDED PIPING SHALL BE GROOVED SCHEDULE 10 WITH THREAD-0-LETS. ALL PENETRATIONS THRU FIRE RATED WALLS SHALL BE PROPERLY SEALED USING UL LISTED METHODS AND APPROVED PRODUCTS TO MAINTAIN RATING OF WALL. ADJUSTABLE SWIVEL RING TAIL U) z O N 5 1 w w w 0 � m m � Q o 0 0`0 zz 0 0 0 ... U o cc� v b A H N FIRE PROTECTION FLOOR PLAN %DC. PEMMT it 9209 CAPSC4 JW J% T907 PRAM 8)% 1 SCALE: AS SHE QATE- 8110 FP--1 of 1