Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
09-9708
CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780 -0020 9708 FIRE SPRINKLER SYSTEM PERMIT ,. P ' *• �gy b•• , .. Permit Number: 9708 Address: 7860 GALL BLVD Permit Type: FIRE SPRINKLER SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE - SPRINKLER SYS Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 35- 25 -21- 0130 - 00000 -0140 Improv. Cost: 2,900.00 = z €h. , : f - ;T ., . :, gtV, 5 Date Issued: Name: ZEPHRY COMMONS LLC Total Fees: 165.00 Address: 3629 MADACA LANE Amount Paid: 165.00 TAMPA FL 33618 Date Paid: 11/05/2009 Phone: (813)933 -0629 Work Desc: FPM -FIRE SPRINKLER INSTALLED H& R BLOCK �di:: € ,o "as ° a,£::'''. °B .�3'�+e°a.. A } w' ei a �`sf'•.. ,.. �.s- AP • 1 - IN FIRE -- INKL - Y 50.00 FIE 1 - E TION S 65.00 FIRE PLAN REVIEW FEES 50.00 p(AQ "!4114-1' €€**uk V � ... 1= - T T FIRE ACCEPTANCE Final Chapter 633, Florida Statutes, authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees, and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of $100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." _ CONTRACTO SIGNATURE • r 3j I IC R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT - Fire Marshal Office - 813- 780 -0041 , , A mio6 813 780 -0020 City of.ZephyrhillsFire Fax - 813-780 -0021 , Permit Application Date Received /00.470/ Phone Contact for Permit 91 3 162-8" 4`lcn T rrcnt .... .�y Owner's Name `4 ff 440 GI( Owner's Phone Number Owner's Address ?86,o Gam- ,L-V 0 Fee Simple Titleholder Name Titleholder Phone Number Fee Simple Titleholder Address r rammo:.A" «<, .,,, »a „a, ,: <'r.; ', -,,,. . . rk. ;mom. e :s•1,.., , .:,: >,,,,- d ". RZTO,;.,Trar".wa, i�til%,, 1 !Itr t;,;. /N.. a Job Address 7,96o 6'4 (A-- j LV Lot* Sub Division ' "7 a --P/ 4 1/ ( e 6AM-40" S Parcel # Bio -Hazard Waste Storage - ANNUAL n Fumigation Tent Comm Exhaust Kitchen Hood /Duct I , 1 Hazardous Material (Tier I I or RQ Facility) ANNUAL Controlled Bum I Hood Installation n Emergency Generator < 30 kw n LP /Natural Gas - Installation Emergency Generator> 30 kw n LP /Natural Gas - ANNUAL Sale n Fire Protection Maintenance - ANNUAL I Places of Assembly- ANNUAL 1 IUtnyl ISemiI tither Sprinkler n ❑ ❑ ❑ n Recreational Bum Fire Alarm n ❑ ❑ ❑ I 1 Sparklers Hood Cleaning n ❑ ❑ ❑ IG Sprinkler System Installations ‘:...; Hood Suppression ❑ ❑ ❑ I I Standpipes (Sprinkler Sys) rn Fire Alarm Installation n Torch Roofing/Tar Kettle . Fire Pumps n Waste Tire Storage ANNUAL Fire Works Flammable Application - ANNUAL I 2'9 cep 1 Valuation of Project Fuel Tanks 1n Other: I Contractor 0(4G 71 Company C_ 4 V ,�7 U S vvc_ - Signature J`l / Registered Y / N Fee Current I Y / N Address 1 '44s r, .404 m o Da_ TPA. f`ti 33 3 1 License# ELECTRICIAN Company . Signature Registered Y/ N I Fee Current Y/ N Address I I License # I PLUMBER Company Signature Registered _ Y / N _ Fee Current 1 Y / N Address 1 License* MECHANICAL Company Signature Registered Y/ N Fee Current 1 Y / N Address 1 I License* 1 OTHER . Company Signature Registered Y/ N J Fee Current I Y / N I Address j License # Directions: Fill out application completely. Owner & Contractor sign back of application, notarized (Or, copy of signed contract with owner) If over $2500, a Notice of Commencement is required .(Mechanical work over $5000) Supply two (2) sets of drawings with applicable documentation Allow 10 -14 days for review after submittal date. Parcel # - obtained from Property Tax Notice (http: /lappraiser.pascogov.com). NOTICE OF 'DEED RESTRICTIONS: The undersigned understands that this permit may subject'to "deed ":restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for:complianbe with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has - hired :a - contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may .apply for the intended work, they are advised to contact the Pasco County Building Inspection Division — Licensing Section. at 727 -847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION .LIEN LAW (Chapter713, Florida Statutes,. as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law — Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner ", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S /OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE 'OF 'COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT (F.S. 117.03) OWNER OR AGENT CONTRACTOR Subscribed_ and swom to (or affirmed) before me this Subscribed and sworn to (or affirmed) before me this by . b Who is /are personally known to me or has /have produced Who is /are personally known to me or has /have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed, printed or stamped Name of Notary typed, printed or stamped Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (813) 780 -0041 Kerry Barnett Fax (813) 780 -0044 E- mail: kbarnett @fire.zephyrhills.fl.us Plan Review 4: 09 -090 Project: Sprinkler Modification Number of Pages: 1 page plus Packet October 30, 2009 I have received and reviewed the plan for the fire sprinkler modification located at 7860 Gall Blvd and will allow the project to move forward. By paying for permit, contractor acknowledges to comply with the items listed below. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. 1. NFPA 13, 2007 edition shall be followed. City has ordinance that adopts latest edition of NFPA codes. 2. Ensure penetrations in fire wall meet the UL W -L -1054 listing submitted with paperwork. If not redo penetrations. Mineral wool is required as filler. Inspections Required: 1. Pressure Test at normal operating pressure unless area can be zoned off. 2. Final A ' ETT, FIRE MARSHAL ** *Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a fmal approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Fire Chief Keith Williams Bus (813)780 -0041 Fax (813)780 -0044 FIRE SERVICE USER FEES Occupancy No.: r -- Plan No.: d a — S ,, Contractor: 'ccet? ,d, i. i Business Name: •rird i1zr Billing Address: .*" 4' . 7-- �i I I Business Address: • ii 6)41/ AJ i 3.Jb/9 Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: _ PLAN REVIEW FEES _ INSPECTION FEES PERMIT F _ FALSE ALARM FEE Site Plan N/C _ Annual N/C ri Sprinkler ` 1st Alarm N/C _ Multi -Family/Commercial .06 sf _ 1st Re- inspection N/C III Standpipes 1 _ 2nd Alarm N/C (Minimum Charge $25.00 _ 2nd Re- inspection $100 III Fire Pump $50 _ 3rd Alarm N/C El Plan Revisions DBL _ 3rd Re- inspection $250 , Hoods $50 _ 4th Alarm $100 4th Re- Inspection $500 , Fire Alarm $50 _ 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until II LP Gas $50 _ 6th Alarm $200 tm 0 - 25 Heads $50 violations corrected) ,Natural Gas $50 _NON COMPLIANCE 5150 26 plus Heads SPRINKLER SYSTEMS ,Fuel Tanks- per tank $50 STANDPIPE SYSTEM Hydro Undergrounds I Sparklers 5100 0 Per Riser $50 Hydrostatic Test per system . Fire Works $500 FIRE PUMP Acceptance Test $45 per system 1 Camp Fire $25 El Per Pump $100 Hydrant Flow 575 ■ Controlled Bum $100 FIRE ALARM SYSTEM , Hood/Duct $50 0 - 25 Devices 550 _ FIRE ALARM SYSTEM II Place of Assembly $50 Annual 26 plus Devices $100 _ System Acceptance 550 , Fire Protection $25 SUPPRESSION SYSTEMS _ Recall Acceptance $50 . Flammable Application $50 Annual Wet $50 _ OTHER , Waste Tire Storage $50 Annual — Dry $50 _ Fire WaIl/Smoke Wall $15 per wall , Generator < KW $100 _ CO2 $50 _ LP Gas $25 per tank , Generator >30 KW 150 — Other $50 _ Natural Gas $25 per system , Bio-Hazard Waste $100 Annual KITCHEN EXHAUST _ , Fumigation Tenting $50 E i Hood/Ducts 550 _ Tent 10'x10' or greater $15 per tent , Torch Pot/Applied $50 OTHER _ Fire Pump $45 II Haz. Materials 5100 Annual LP Installation per tank $50 _ Fire Suppression $30 Fuel Tank Installation 550 _ System Acceptance (Per Tank) $50 _ Exhaust Hood/Duct $30 0 Natural Gas Installation $50 _ Re - inspection DBL (Per System) (other than annual) _ Ei Spray Booth $50 El Inspection scheduled DBL _ and cancelled less than _ _ 24 hours _ Construction Insp. N/C Emergency Vehicle Ac $50 FALSE ALARM PLANS TOTAL ItJ INSPECTION TOTAL � PERMIT TOTAL k TOTAL GRAND TOTAL 1 /-6. " 1 Comments: Date: /01 4/a 9 Inspector: )- m-.9 - / r -"_--- • • Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (813) 780 -0041 Kerry Barnett Fax (813) 780 -0044 E -mail: kbamett @fire.zephyrhills.fl.us Plan Review #: 09 -090 Project: Sprinkler Modification Number of Pages: 1 page plus Packet October 30, 2009 I have received and reviewed the plan for the fire sprinkler modification located at 7860 Gall Blvd and will allow the project to move forward. By paying for permit, contractor acknowledges to comply with the items listed below. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. 1. NFPA 13, 2007 edition shall be followed. City has ordinance that adopts latest edition of NFPA codes. 2. Ensure penetrations in fire wall meet the UL W -L -1054 listing submitted with paperwork. If not redo penetrations. Mineral wool is required as filler. Inspections Required: 1. Pressure Test at normal operating pressure unless area can be zoned off. 2. Final 0/ AdiEtt �I '' ' ETT, FIRE MARSHAL KERB .� ** *Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Fire Chief Keith Williams Bus (813)780 -0041 Fax (813)780 -0044 FIRE SERVICE USER FEES Occupancy No.: Plan No.: d'" -- 0 1 Contractor: ' ' C� 4 d i le... Business Name: "fir i' ' Billing Address: ,''4/ , i' Business Address: • 0 6)4-// / th1 �(_ f. .s :5&i9 Business Phone No.: Billing Phone No.: / Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES _ INSPECTION FEES PERMIT F _ FALSE ALARM FEE Site Plan N/C _ Annual N/C ri Sprinkler _ 1st Alarm N/C _ Multi Family /Commercia .06 sf _ 1st Re- inspection N/C II Standpipes v o _ 2nd Alarm N/C (Minimum Charge $25.00 _ 2nd Re- inspection $100 , Fire Pump $50 — 3rd Alarm N/C 0 Plan Revisions DBL _ 3rd Re- inspection $250 II Hoods $50 4th Alarm $100 4th Re- Inspection $500 ■ Fire Alarm $50 — 5th Alarm $150 — SPRINKLER SYSTEMS (Business closed until II LP Gas $50 _6th Alarm $200 0 - 25 Heads $50 violations corrected) , Natural Gas $50 — NON COMPLIANCE $150 26 plus Heads SPRINKLER SYSTEMS II Fuel Tanks - per rank $50 STANDPIPE SYSTEM Hydro Undergrounds iiii , Sparklers $100 0 Per Riser $50 Hydrostatic Test il7 per system . Fire Works $500 FIRE PUMP Acceptance Test $45 per system , Camp Fire $25 0 Per Pump $100 Hydrant Flow $75 , Controlled Bum $100 FIRE ALARM SYSTEM , Hood/Duct $50 — 0 - 25 Devices $50 _ FIRE ALARM SYSTEM , Place of Assembly $50 Annual 26 plus Devices $100 — System Acceptance $50 II Fire Protection $25 SUPPRESSION SYSTEMS _ Recall Acceptance $50 , Flammable Application $50 Annual Wet $50 _ OTHER , Waste Tire Storage $50 Annual Dry $50 — Fire Wall/Smoke Wall $15 per wall , Generator < KW $100 — CO2 $50 _ LP Gas $25 per tank , Generator >30 KW 150 Other $50 _ Natural Gas $25 per system , Bio-Hazard Waste $100 Annual KITCHEN EXHAUST _ ■ Fumigation Tenting $50 ❑ Hood/Ducts $50 _ Tent 10'x10' or greater $15 per tent , Torch Pot/Applied $50 OTHER — Fire Pump $45 , Haz. Materials $100 Annual _ LP Installation per tank $50 _ Fire Suppression $30 Fuel Tank Installation $50 _ System Acceptance (Per Tank) $50 _ Exhaust Hood/Duct $30 Natural Gas Installation $50 _ Re - inspection DBL (Per System) (other than annual) 0 Spray Booth $50 0 Inspection scheduled DBL and cancelled less than _ _ 24 hours — Construction Insp. N/C Emergency Vehicle Ac_ $50 FALSE ALARM PLANS TOTAL s INSPECTION TOTAL 1261 .....- PERMIT TOTAL TOTAL GRAND TOTAL I 1 . 5 . -�'' Comments: / Date: /0)4/ ° I InspiRctor: /,a Capsco Industries 8445 East Adamo Drive Tampa, Florida 33619 Ph: 813- 628 -4700 Fx: 813- 628 -4766 FLORIDA LICENSE NO. 14044500012009 Building Dept. Permit #9598 Equipment Material Submittals for H &R Block at Zephyr Commons 7860 Gall Blvd. (U.S. Hwy 301) Zephyrhills, Florida 33541 General Contractor: Faith Bilt Builder, Inc. 4101 Windtree Drive Tampa, Florida 33624 Fx: (813) 962 -1913 SUBMITTED PLAN(S) HAVE BEEN REVIEWED BY ZEPHY ILE MARSHAL' CE Date: v %� Reviewer: iii H &R Block at Zephyr Commons Equipment Material Submittal Table of Contents Sprinkler Heads & Accessories Manufacturer Model "M" Quick Response (Pendent) Viking Misc. Material Hilti UL Listed Details HILTI FS -ONE Firestop / Sound Stop Sealant HILTI Industrial Bulk Wool Thermafiber Above Ground Piping Fittings Threaded Cast Iron Nipples & Fittings AnvilStar Hangers & Hanger Material 3/8" Universal C -Clamp AnvilStar Intl. Inc. 1" Adjustable Loop Hanger AnvilStar Intl. Inc. 3/8" Zinc Plated All Thread Rod AnvilStar Intl. Inc. Above Ground Piping 1" Sched 40 Pipe (Thrd) Allied Fire Protection Shop Drawing Capsco Industries Under Separate Cover (24 x 36) Capsco Industries 8445 East Adamo Drive, Tampa, FL 33619 Ph: 813 - 628 -4700 Fx: 813 - 628 -4766 Auglst 27, 2004 Sprinkler 41 a NIKIN® MICROFAST & MicrofastHP TECHNICAL DATA QUICK RESPONSE PENDENT SPRINKLERS 1. PRODUCT NAME 12104. Copper UNS- C19500 for Viking Microfast® and MicrofastHP® Sprinkler 12282. Brass UNS- C26000 Model M Quick Response Pendent for all other Part Nos. Sprinklers Bushing (for Sprinkler Base Part Nos. 2. MANUFACTURER 06718B, 06720B, and 12290): Brass UNS- C36000 is - . The Viking Corporation Bulb: Glass, nominal 3 mm diameter 210 N. Industrial Park Road Belleville Spring Sealing Assembly: Hastings, Michigan 49058 U.S.A. Nickel Alloy, coated on both sides Telephone: (269) 945 -9501 with Teflon Tape (877) 384-5464 Screw: Brass UNS- C36000 Fax: (269) 945 -9599 Pip Cap and Insert Assembly: Copper • e -mail: techsvcs ©vikingcorp.com UNS-C11000 and Stainless Steel 3. PRODUCT DESCRIPTION 4. TECHNICAL DATA UNS- S30400 Viking Microfast® and MicrofastHP® LISTINGS AND APPROVALS Pip Cap Attachment: Brass UNS- C36000 Quick Response Pendent Sprinklers Refer to the Approval Chart on page 41 b. Ejector e (Part No. 12104): Stain - are small, thermosensitive spray sprin- Glass -bulb fluid temperature rated to less Steel l klers available with several finishes, -65 °F ( -55 °C). Sprinklers with Teflon® Coating temperature ratings, and orifice sizes to Minimum Operating Pressure: 7 psi Belleville Spring: Nickel Alloy, exposed meet design requirements. The special (48,3 kPa) Screw: Brass UNS- C36000, Nickel Poly finishes and Teflon® coatings can RATED WATER WORKING PRES- plated be used in decorative applications SURE Pip Cap: Teflon® Coated where colors are desired. In addition, Sprinklers VK317 and VK342 are Sprinklers with Polyester Coating or these two finishes are corrosion resis- rated for use with water working Poly Finish tant and provide protection against pressures ranging from the mini- Belleville Spring: Nickel Alloy, exposed many corrosive environments. mum 7 psi (48,3 kPa) up to 250 psi (1 AVAILABLE FINISHES The pip cap and sealing assembly of the 724 kPa) for high - pressure sys- Brass, Chrome- Enloy® (patents pend- sprinkler is held in place by a bulb tye tams. High - pressure (HP) sprin- ing), White Polyester (White Poly finish operating element. During fire condi- klers can be identified by locating for Sprinkler 06662B), Black Polyester tions, when the temperature around the the number "250" on the deflector. (Black Poly finish for Sprinkler 06662B), sprinkler reaches its operating tempera- All Other Sprinklers: Maximum 175 and Black Teflon® ture, the heat - sensitive liquid in the psi (1 207 kPa) wwp. ACCESSORIES glass bulb expands, causing the bulb to Factory tested hydrostatically to 500 psi Sprinkler Cabinets (Available since shatter, releasing the pip -cap and seal- (3 448 kPa). 1971): ing spring assembly. Water flowing Testing: U.S.A. Patent No. 4,831,870 A. Six -head capacity: Part No. through the sprinkler orifice strikes the SPRINKLER MATERIALS 01724A sprinkler deflector, forming a uniform Frame: Brass Castings UNS- C84400 B. Twelve -head capacity: Part No. spray pattern to extinguish or control the Deflector: Brass UNS- C51000 or Cop- 01725A fire. per UNS- C19500 for Sprinkler Base Sprinkler Wrenches: Part Nos. 06662B, 06666B, 06765B, A. Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Temperature Nominal Sprinkler Temp. Maximum Ambient Bulb or 05000CW /B (no longer avail- Classification Rating (Fusing Point) Ceiling Temperature Color able). Ordinary 155 °F (68 °C) 100 °F (38 °C) Red B. Wrench for coated and recessed Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Viking Microfast® and MicrofastHP® Intermediate 200 °F (93 °C) 150 °F (65 °C) Green QR Pendent Sprinklers: Part No. High 286 °F (141 °C) 225 °F (107 °C) Blue 07398W* (available since 1990), Sprinkler Finishes: Brass, Chrome- Enloy® (patents pending), White Polyester (White Poly or Part No. 12144W/B ", available finish for P/N 06662B), Black Polyester (Black Poly finish for P/N 06662B), and BlackTeflone since 2003. NOTE: Recessed Corrosion - Resistant Coatings White Polyester (White Poly finish for P/N 06662B), Black pendent sprinklers with protec- Polyester (Black Poly finish for P/N 06662B), and Black Teflon® tive caps must use wrench Footnotes 12144W/B. 1 Based on NFPA -13. Other limits may apply, depending on fire loading, sprinkler location, *A 34" ratchet is required (not available through and other requirements of the Authority Having Jurisdiction. Refer to specific installation Viking). standards. Refer to the "SPRINKLER ACCES- 2 The temperature rating is stamped on the deflector. SORIES" section of the Viking Engi- 3 The corrosion - resistant coatings have passed standard corrosion tests required by particu- veering and Design Data book. lar approving agencies. Refer to the approval chart on page 41 b. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. The coatings indicated are applied to the exposed exterior surfaces only. NOTE: The spring is exposed on sprinklers with Teflon® Coating or Poly finishes. Note: Units of measure in parentheses may be approximations. Replaces page 41 a - dated May 14, 2004 (updated deflector Form No. F 081296 materials). Refer to technical data page QR1 - 2 for care, In stallation, and maintenance information. Sprinkler 41 b August 27, 2004 ® MI & MicrofastHP ,,o= .; QUICK RESPONSE PENDENT SPRINKLERS Approval Chart Temperature KEY Microfast and MlcrofastHP Quick Response 1� �� Finish Pendent Sprinklers AtX. Escutcheon (if applicable) Maximum 175 PSI WWP Standard • riflce 1 l- • L - < <: Base Part SIN, g n i «� : - •� r • i NPT ® Numbed cULuss FM NYC VdS LPCB CE 5 Large Orifice 3/4" 20 mm 175 06666B VK352 R.0 11,5 9 -3 /R 60 A3X B3Y A9X, B9Y A3X, R3Y — — -- 3/4" 20 mm 175 12104 VK352 8.0 11.5 2 -1/4 58 — — — C2 — — W 15 mm 175 06765B VK352 8.0 11.5 2:3/8 60 A3X 13Y — 43X. B3Y — — -- Small Orifice W 15 mm 175 06718lie VK329 2.8 4.0 2 -3/16 56 A3X. B3Y A2X A3X. B3Y — — W 15 mm 175 06720 VK331 4.2 6.0 2 -1/4 58 A3X. B3Y — A3X. B3Y — — — — 10 mm 175 06932B VK331 4.2 6,0 2 -3/8 60 — — — C2 — — Maximum 250 PSI WWP Standard Orifice Thre d Size Max. Pressure Base Part NominalX- Factor Overall Length Listings and Approvals NPT BSP PSIG Numbers SIN U.S. metric Inches mm cULuss FM NYC VdS LPCB (E Ye 15 mm 250 12282 VK317 5.6 8.1 2;1/4 58 A3X. B3Y — A3X — — — • 1 " i� Ii7MM'�.��Mi' � M ' �rIII IMMIV:I/_rc3 — IIIIMMENI — — Approved Finishes Approved Escutcheons Approved Temperature Ratings e White Poly Finish �, Black X - Standard surface- mounted escutcheon 1- Brass, Chrome -Enlo A - 155 °F (68 °C), 175 °F (79 °C), 200 °F Poly Finish and Black Teflon ®i1 or the Viking Microfa ot Model F-1 Ad (93 °C), and 286 °F (141°C) 2 - Brass and Chrome- EnloVe justable Escutcheon 68 °C , 175 °F 79 °C ,and 200 °F 3 - Brass, Chrome Enl eon or the Viking Microfast Model F -1 Y - Standard surface - mounted escutch- B -155 °F ( ) ( ) h oy®, White Pdyester Black (93 C) Polyester ,and Black Teflon Adjustable Escutcheon or recessed C -155 °F (68 °C) 4 - Brass, Chrome -Enloy , White Poly Finish, and Vidng Micromatic® Model E -1 or Black Poly Finish E? Rai:Aced Fcmtrhenn Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 3 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219- 76-SA. 4 The sprinkler orifice is bushed. 5 CE Certified, Standard EN 12259 -1, EC- certificate of conformity 0832 -CPD -2001. 6 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 7 cULus Listings and NYC Approvals limited to Light- Hazard Occupandes with hydraulically calculated wet systems. 8 Metric K-Factor shown is for use when pressure is measured in kPa. When pressure is measured in BAR, multiply the metric K-Factor shown by 10.0. 9 FM Approved for use only in wet -pipe sprinkler systems (or preactlon systems quaifying as wet systems) for protection of occupandes de- scribed in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. 10 The Viking Microfast® Model F -1 Adjustable Escutcheon is considered a surface- mounted escutcheon because it does not allow the fus ibl eel e- ment of the sprinkler to be recessed behind the face of the wall or ceiling. 11 cULus Listed as corrosion resistant. 12Acce for use, City of New York Department of Buildings, MEA 89 -92 -E, Vol XVI. 13 Refer to the "Sprinkler Accessories" section of the Viking Engineering and Design Data book for technical data on approved escutcheons and other accessories. Quick Response Pendent Sprinkler 2 -1/8" with a Standard 1/8" (3,1 mm) �(54 mm) 1 2 - Surface - Mounted Escutcheon (54 mm) ii. ill 2-1/4" - .ii 1: .i.E (58 mm) I 1 1 � �� a 1_" (51 mm) 1110 � Mi n i mum (32 mm) T (45 ) Maximum OT-1 1-1/8" 2" i Mlni(28,6 mm) mum A 1 (14;3/4") m u j Quick Response �� Maximum Pendent Sprinkler Quick Response Pendent Sprinkler .O..." Installed with the Viking Microfaste Adjustable Escutcheon Quick Response Pendent Sprinkler Model F -1 Ad j Ceiling Opening Size: 2-5/16" (59 mm) Minimum, Installed with the Viking Micromatic® 2 -1/2" (64 mm) Maximum. Model E -1 Recessed Escutcheon Figure 1 Replaces page 41 a -b, dated May 14, 2004 (updated deflector materials). Refer to tech- Form No. F_081296 nical data page QR1 -2 for care, installation, and maintenance information. �1�� I ..iiltl. C1ut�' >, rturm. Uuttr�st. Firestop Submittal 800-879-8000 • www.hilti.us Sprinkler Submittal: Flat Concrete Metallic & Combustible Penetrants (Cast -In Option) Barrier Penetration Type Max. Penetration Size Annular Space F- Rating System N ber Product um Steel, Cast Iron, Floor Copper, Steel Conduit, 4" EMT; 6" others (See Detail) 3 hours F -A -1017 CP 680P / M; EMT CP 618 Floor PVC CPVC RNC 6" all See Detail 3 hours F -A -2054 CP 680P Floor ABS FRPP 4" ABS. 6" FRPP See Detail 3 hours F -A -2066 CP 680P Barrier Penetration Type Max. Penetration Size Annular Space F- Rating System Number Product Steel, Cast Iron, 30" Steel or Cast Iron; Wall Copper, Steel Conduit, 6" Copper or Steel 0" to 2 -1/4" 1 or 2 hours W -L -1054 FS One EMT Conduit 4" EMT PVC, CPVC, ABS, 10" PVC or CPVC; 6" FS One; CP Wall FRPP, PVDF ABS or FRPP; 4" PVDF 0" to 1/2" 1 or 2 hours W -L -2078 643N or CP 644 Wall PVC CPVC 2" either 1/4" to 11/16" 1 or 2 hours W- L-2128 FS One r r Barrier Penetration Type Max. Penetration Size Annular Space F- Rating System N ber Product LL um Steel, Cast Iron, 30" Steel or Cast Iron; Floor / Wall Copper, Steel Conduit, 6" Copper or Steel 0" to 1 -7/8" 3 hours C -AJ -1226 FS One EMT Conduit 4" EMT 6" and smaller PVC, CPVC, ABS, 10" PVC or CPVC; (0" to 1/2 "); CP 643; or Floor / Wall FRPP 6" ABS or FRPP larger than 6 2 or 3 hours C -AJ -2109 CP 644; FS 0" to 1-1/4" One Floor / Wall PVC, CPVC 3" either 1/2" to 2" 3 hours C -AJ -2141 FS One; CF 810 or CF 812 Barrier Penetration Type Max. Penetration Size Annular Space F- Rating System Product Number Steel, Cast Iron, 30" Steel or Cast Iron; Wall Copper, Steel Conduit, 6" Copper or Steel 0" to 2 -1/4" 1 or 2 hours W -J -1067 FS One EMT Conduit 4" EMT Wall PVC CPVC 2" either 1/4" to 11/16" 1 or 2 hours W -J -2108 FS One UUcUL SYSTEM NO. W -L -1054 METAL PIPE THROUGH 1 -HR. OR 2 -HR. GYPSUM WALL ASSEMBLY F- RATING = 1-HR. OR 2 -HR. T- RATING = 0 -HR. L- RATING AT AMBIENT = LESS THAN 1 CFMISQ. FT. L- RATING AT 400 °F = 4 CFM/SQ. FT. FRONT VIEW 0 SECTION A -A 0 A © ' 11 51 0 "Midi ■ A f - 1. GYPSUM WALL ASSEMBLY (UUULC CLASSIFIED U300 OR U400 SERIES) (1 -HR. OR 2 -HR. FIRE - RATING) (2 -HR. SHOWN). 2. (NOT SHOWN). WOOD STUDS TO CONSIST OF NOMINAL 2" x 4" LUMBER. STEEL STUDS TO BE MINIMUM 2-1/2" WIDE. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 30" DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER). B. MAXIMUM 30" DIAMETER CAST IRON PIPE. C. MAXIMUM 6" NOMINAL DIAMETER COPPER PIPE. D. MAXIMUM 6" NOMINAL DIAMETER STEEL CONDUIT. E. MAXIMUM 4" NOMINAL DIAMETER EMT. 4. MINIMUM 5/8" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT. 5. MINIMUM 112" BEAD HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT AT POINT OF CONTACT. NOTES : 1. MAXIMUM DIAMETER OF OPENING : A. 32-1/4" FOR STEEL STUD WALLS. B. 14-1/2" FOR WOOD STUD WALLS. 2. ANNULAR SPACE = MINIMUM 0 ", MAXIMUM 2-1/4". 3. PIPE MAY BE INSTALLED WITH CONTINUOUS POINT OF CONTACT. 4. PIPE MAY BE INSTALLED AT AN ANGLE NOT GREATER THAN 45° FROM PERPENDICULAR. n ' f Sheet 1 of 1 Drawing No. ,_a ' `� �'D® HILTI, Inc. Scale 7/32 ° =1° WL FIRESTOP SYSTEMS Tulsa, Oklahoma USA (918) 252 -6000 Date Nov. 6, 2002 1054q Saving Lives through Innovation and Education 1 Product Information FS -ONE Product description FS-ONE • Intumescent (expands when exposed to fire) firestop sealant High Performance that helps protect combustible and non - combustible penetra- Technical Data bons for up to 4 hours fire rating At 73 °F (23 °C) and 50% relative humidity Intumescent Firestop Product features Chemical basis Sealant • Smoke, gas and water resistant after material has cured Water -based intumescent acrylic dispersion • Contains no halogen, solvents or asbestos Density • High fire rating properties Approx. 1.5 q/cm i u • Water based, easy to clean Color Red n , "" Areas of application Working time • Steel, copper and EMT pipes Approx. 0 -30 min. T Insulated steel and copper pipes Curing time �, • Cable bundles Approx. 4 mm / 3 days c-, 1 Closed or vented plastic pipes Shore A Hardness � Ad va n tage f c us t omer .Benefits • HVAC penetrations Approx. 35 • Protects most cal firestop For use with Movement capability penetra appp • Concrete, masonry, drywall and wood floor assemblies Approx. 5% • r Easy to work with and fast cleanup • Wall and floor assemblies rated up to 4 hours Intumescent Activation • Can be.painted Approx 482 °F (250 °C) • Stn le r om ent ava Examples Expansion rate (unrestricted): g � • Sealing around plastic pipe penetrations in fire rated Up to 3 -5 times original volume • Meets at 1'a indoor construction Temperature resistance (cured) m "x' • Sealing around combustible and non - combustible —40 °F to 212 °F ( -40 °C to 100 °C) Adh , Mar id 4.2 penetrations in fire rated construction Application temperature ;' Atlhesiv�. �rtd'4.�;Patttt5'ar>il'CtYatir� ' Pe Ap pe 41 °F to 104 °F (5 °C to 40 °C) Installation instructions for FS-ONE Surface burning characteristics Opening Notice about approvals (ASTM E 84 -96) 1. Clean the opening. Surfaces to which FS -ONE will be • Check that the penetration has been sealed according to Flame Spread: 0 applied should be cleaned of loose debris, dirt, oil, the specified drawing in the UL Fire Resistance Directory Smoke Development: 5 moisture, frost and wax. Structures supporting or Hilti Firestop Manual. For further advice, please Sound transmission dassification penetrating items must be installed in compliance with contact Hilti customer service. Refer to Hilti product (ASTM E 90 56 local building and electrical standards. literature and UL fire resistance directory for specific application details. is Application of firestop sealant IICCBO Approvals Conference of 2. Install the prescribed backfilling material type and depth Not for use... Building Officials) to obtain the desired rating (if required). Leave sufficient • High movement expansion joints Report No. 5071 depth for applying FS -ONE. • Underwater 3. Application of firestop sealant: Apply FS -ONE to the • On materials where oil, plasticizers or solvents may Cati No. State 485- Fire Marshal bleed i.e. impregnated wood, oil based seals, green or City Listing No. 4485 -1200:108 required depth in order to obtain the desired fire rating. Pfe9 � City y of New York Make sure FS -ONE contacts all surfaces to provide partially vulcanized rubber MEA 326-96-M maximum adhesion. For application of FS -ONE use a • In any penetration other than those specifically standard caulking gun, foil pack gun, bulk loader and described in this manual or the test reports ,„ bulk gun. With FS -ONE buckets, Graco type sealant safety s Tested in accordance with pumps may be used. (Contact pump manufacturer for • tlon • UL 1479 ' ^ proper selection). •Before handling, handandling, read the product and Material Safety Data Sheet for detailed use and health information • ASTM E 814 4. Smoothing of firestop sealant: To complete the seal, tool • Keep out of reach of children • ASTM E 84 immediately to give a smooth appearance. Excess • Wear suitable gloves and eye protection sealant, prior to curing, can be cleaned away from Storage Internationally tested and approved adjacent surfaces and tools with water. • Store only in the original packaging in a location oJ .ss, gp F LUO ORlAVITY►WE(C I 5. Leave completed seal undisturbed for 48 hours. protected from moisture at temperatures between rorzusE xwnxmu�l aee�� 6. For maintenance reasons, a penetration seal could be 40 °F (5 °C) and 86 °F (30 °C) CL SEE � FIRE RESISTANCE US WC DIRECTORY permanently marked with an identification plate. In such • Observe expiration date on the packaging a case, mark the identification plate and fasten it in a visible position next to the seal. APPROVED vi . ,��, _ ' W1I1 f , . P SYST /M COMMTIKI 1 _ _._ , Lr 1. clean opening. 2. Pack mineral 3. Apply FS -ONE. 4. Smooth FS -ONE. S. Leave ca► 6. Fasten identifi- wool. (If required) seal undtshr6ed for cation plate (if T i 48 hoes. required). © latest product information : www.us.hilti.com ...., I E © ordering information see page: 34 , 1. Clean opening. 2. Pack mineral 3. Apply FS -ONE. 4. Smooth FS-ONE. S. Leave 6. Fasten iderxifica- wool. (If required) seal undisturbed ar tan plate (if Saving Lives through innovation & education I Hilti Firestop Guide' i • - 2006 1 1'x!79 -8000 1 www.us.hilti.com MIIL.•l " 17 Mato1,i! Eatety L }Jt 9 : 'h4 *' 1■yId'TI MSDS No.: 259 Revision No.: 010 Revision Date: 08/17/04 Page: 1 of 2 Product identifier: FS -ONE High Performance Intumescent Firestop Sealant Description: One -part acrylic -based sealant Supplier: Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121 Emergency # (Chem - Trec.): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) :; INGREDIENTS AND EXPOSURE LIMITS CD L, Ingredients: CAS Number: PEL: TLV: STEL: Polyacrylate dispersion Mixture NE NE NE Calcium carbonate 001317 -65 -3 5 mg /m' (1) 10 mg /m' (T) NE Zinc borate 138265 -88 -0 NE NE NE Ammonium polyphosphate 068333 -79 -9 NE NE NE Talc 014807 -96 -6 20 mppcf 2 mg /m NE Expandable graphite 012777 -87 -6 5 mg /m' (T) 2 mg /m (T) NE Ethylene glycol 000107 -21 -1 NE C:100 mg /m' (A) NE Polybutene 009003 -29 -6 NE NE NE J, Iron oxide 001309 -37 -1 10 mg /m 5 mg /m' NE Glass filament 065997 -17 -3 NE 5 mg /m' (T) NE :y. Silicon dioxide 014808-W-7 0.05 mg /m' ( 0.1 mg /m' (T) NE Water 007732 -18 -5 NE NE NE Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. C = Ceiling. STEL = Short Term Exposure Limit. NE = None Established. NA = Not Applicable. (i) indicates "as total dust ". (R) indicates "as respirable fraction ". (A) indicates "as an aerosol'. mppcf million particles per cubic foot. PHYSICAL DATA Appearance: Red paste. Odor: Odorless. Vapor Density: (air = 1) Not determined. Vapor Pressure: 23mbar @ 20C / 68F Boiling Point: Not applicable. VOC Content: 75.0 g/L. Evaporation Rate: Not applicable. Solubility in Water: Soluble. Specific Gravity: 1.5 pH: Not determined. FIRE AND EXPLOSION HAZARD DATA j Flash Point: Non - flammable. Flammable Limits: Not applicable. Extinguishing Media: Not applicable. Use extinguishing media as appropriate for surrounding fire. Special Fire Fighting Procedures: None known. Use a self- contained breathing apparatus when fighting fires involving chemicals. Unusual Fire and Explosion Hazards: None known. Thermal decomposition products can be formed such as oxides of carbon, sulfur and phospho- rous. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. � Incompatibility: Strong acids, peroxides, and oxidizing agents. o Decomposition Products: Thermal decomposition can yield CO and CO2. v Conditions to Avoid: None known. 1— HEALTH HAZARD DATA W Known Hazards: None known. co Signs and Symptoms of Exposure: Possibly irritating upon contact with the eyes or upon repeated contact with the skin, Medical Conditions Aggravated by Exposure: Eye and skin conditions. cD Routes of Exposure: Dermal. cz Carcinogenicity: IARC classifies crystalline silica (quartz sand) as Group I based upon evidence among workers in industries where there has been long -term and chronic exposure (via inhalation) to silica dust; e.g. mining, quarry, stone `-' crushing, refractory brick and pottery workers. This product does not pose a dust hazard; therefore, this clas- sification is not relevant. Based upon the nature and intended use of this product, it does not pose an increased cancer risk to workers. 454 MIILTI ' Saving Lives through innovation & education 1 Hilti Firestop Guide 2005 -2006 1 1- 800 - 879 -8000 I www.us.hilti.com !MILET♦ Material Safety Data Sheet MSDS No.: 259 Revision No.: 010 Revision Date: 08/17/04 Page: 2 of 2 EMERGENCY AND FIRST AID PROCEDURES Eyes: Immediately flush with plenty of water. Call a physician if symptoms occur. Skin: Immediately wipe off material and wash with soap and water. Material can adhere to the skin. If material has adhered to the skin, use an abrasive containing hand cleaner. If material does not come off, buff with a pumice stone. Inhalation: Move victim to fresh air if discomfort develops. Call a physician if symptoms persist. Ingestion: Seek medical attention. Do not induce vomiting unless directed by a physician. If a large quantity was ingest- ::: ed, give 1 to 2 glasses of water to dilute. Never give anything by mouth to an unconscious person. Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General (natural or mechanically induced fresh air movements). Eye Protection: Not required, however, safety glasses should be worn in most industrial settings. Skin Protection: Avoid skin contact. Cloth gloves are suitable for hand protection. ....... ......... _..................... . Respiratory Protection: None normally required. Where ventilation is inadequate to control vapors, use a NIOSHapproved respirator with organic vapor cartridges. Never enter a confined space without an appropriate air - supplied respirator. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Precautions: Store in a cool, dry area preferably between 40o and 77o F. Keep from freezing. Do not store in �; direct sunlight. Avoid contact with the eyes or skin. Practice good hygiene; i.e. always wash thoroughly after - handling and before eating or smoking. For industrial use only. Keep out of reach of children. Follow t label /use instructions. Spill Procedures: Immediately wipe away spilled material before it hardens. Place in a container for proper disposal in actor- r dance with all applicable local, state, or federal requirements. REGULATORY INFORMATION Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. HMIS Codes: Health 1 Flammability 0, Reactivity 0, PPE B DOT Shipping Name: Not regulated. IATA / ICAO Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory. SARA Title III, Section 313: This product contains < 3% ethylene glycol (CAS 107 -21 -1) and < 15% zinc borate (re: zinc compounds) which are subject to reporting under Section 313 of SARA Title III (40 CFR Part 372). 5: EPA Waste Code(s): Not regulated by EPA as a hazardous waste. Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service: 1 800 879 8000 ................. Health / Safe ty: 1 800 879 6000 Jerry Metcalf (x6704) Emergency # (Chem - Trec): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. • Saving Lives through innovation & education I Hilti Firestop Guide 2005 -2006 1 1- 800 - 879 -8000 I' www.us.hilti.com N1■T1 • 455 Certificate ot Log h aria Certificate Number 20060214- R13240E Page 1 of 1 Report Reference 2006 February 14 Issue Date 2006 February 14 Underwriters L Laboratories Inc. Issued to: Hilti Inc. 5400 S 122ND East Ave Tulsa, OK 74146 USA This is to certify that Fill, Void or Cavity Materials representative samples of FS -ONE Have been investigated by Underwriters Laboratories Inc. ® in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: ANSUUL 1479, ANSUUL 2079, CAN/ULC -S 115 -05 Additional Information: FS -ONE Sealant for use in Joint Systems and FS -ONE for use in Through - Penetration Firestop Systems as currently described in the UL Fire Resistance Directory. Only those products bearing the UL Classification Mark should be considered as being covered by UL's Classification and Follow -Up Service. The UL Classification Mark includes: UL in a circle symbol: S with the word "CLASSIFIED" (as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL's evaluation of the product; and, the product category name (product identity) as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product Issued by: Reviewed by: 11�ouloute Christopher �f on Underwriters Laboratories Inc. Underwriters L.•. oratories Inc. • Thermaliber • NONCOMBUSTIBLE ECONOf,11CAL VERSATILE APPLICATION VARIETY OF USES NONASBESTOS For efficient insulation offering condensation control, acoustical correction and thermal values Variety of Forms, Versatile Uses Packing Wool Thermafiber Bulk Wool offers a choice of granulated wool, Similar to Thermafiber Granulated Wool, but designed for packing wool, spray wool, cryogenic and high - performance hand packing rather than pouring or mixing. Recommended (HP) wool. for heat control In boilers, tanks, expansion Joints and ovens where the shape of the insulation cavity precludes the use of Granulated Wool felt insulation. Thermafiber Granulated Wool consists of mineral fibers Industrial Spray Wool formed into small nodules or pellets. Fibers are air - cleaned and treated with dust - collecting oil. Can be used for hand- A high - quality mineral fiber insulation, Thermafiber Spray poured applications or mixed with other materials as a filler Wool is lightly treated with mineral oil and produced in pellet in insulating cements and foundry molds. form for pneumatic spray application. Adhesives or binders, added by the applicator, prepare this product for spray Industrial Blowing Wool application. Used for fire resistance, condensation control, acoustical correction and thermal insulation when mixed Thermafiber Granulated Wool is also available for pneumatic with binder. Color uniformity cannot be maintained due to application. variables in raw materials and types of adhesives used. Organic treatment content is less than 1% by weight. Fiber melt point exceeds 2000 °F per ASTM C24. Cryogenic Wool Granulated mineral fiber formulated specifically with an oil content (L01) of less than 0.2% by weight. Used for thermal insulation for cryogenic tanks such as liquid oxygen. High - Performance (HP) Wool Dark fiber formed In nodules tor hot surface temperatures up to 1900°E Improved performance: less shrinkage and better thermal conductivity for cements, foundry molds and lid boards, and fireplace chimney applications. Nonadsorbent, Corrosion- Resistant Adsorbs Tess than 2% moisture. Does not corrode steel or aluminum as tested per Federal Specification HH- I -558B. Easily Applied Thermafiber industrial Bulk Wool applies easily by hand or with fast pneumatic application. Fits quickly into grooves, slots and other awkward or hard -to -reach openings. terrndsfiuer /IIIIIIIIIIIIII Iwrfmiit*j o vn //ititili/toa II IIkkoo tik i vh 00.44 imiiiiimottis NO LOidP,0511B E LE090 I is 514, i!lr 'Pt T ,. F E, I. tutgiiA'ii3S Physical Properties - Physical Data • Installed K- tedw --Ih • ie.Ar. sq. • R. •P" Recommended max. Predict density temp. ens side -•F 38-11. Ave. wl. Avg. wt. designation Pr 751 3001 soar (enclosed panel) bailee. R. II. a,. 11.Aals Industrial Bulk Wool (Density varies with parking pressure-three random densities shown.) • Granulated 1 r 4.0 .27 .44 .71 800 30 650 -750 Paddng I 1 8.0 .26 .38 .56 1,200 2.8 30 650 -750 Industrial Spray 1 i 4.0 .27 NA NA NA 2.8 30" 650 -750 Wool J I8.0 .26 Cryogenic Wool .27 NA NA 1,600 NA 30 NA High Performance 7001 10o9•F - (HP) Wool 14.0 NA .69 .98 1,900 2.8 30 650 -750 NA-inot ppaoYa. hold* woell for Ind Doha, grumbled wool for piing, ny wed for noting epPlallow (1) * of Mae MM-nwrlNd derrlaa. (2) InabY» serail tarepwat re. (3) lawns Rod has only 011 W. bap sets wool. - Surface Burning Characteristics Sound Data -Noise Reduction Coefficient (NKr _ Band Center Flgaasey ilex) /1 Flame spread 0, smoke developed 5 per ASTM E84 as tested - Produn Thldmeu 250 _ 500 1000 2000 NRC by Underwriters Laboratories Inc. (UL). Noncombustible as Industrial 2" .66 .85 .83 .87 .80 defined by NFPA and National Fire Code when tested per Spray Wool 4„ 79 .80 .83 .84 .81 ASTM E136. -The addition of any other materials, other than TxcRnwweER Spray Wool, and their affect on Performance being uncontrolled by Thermaeber, are not warranted by Thermaltber. Specification Compliance _ Availability Thermafiiber Industrial Blowing Wool meets ASTM C764. - - Thermafiber 10 Granulated Wool meets U.S. Coast Guard walaen, IN Tacoma, WA Spring Hope, NC Nolamflle, TX Specification 164.009/169/0. - GrontdNded - x - x - x - x 110 Granulated x Paddng x - x " x Spray x x x High Performance x Cryogenic x x The hderrrlbrr pawls! Main For tudtw "Nuneaton on these and taco in accordance Ma our coat plead erauc- such a liquid omen ludo. tae Cryogudc mama laid arswage Mum products, enduing remanded sizes, dory. Ow pebirry dull be apeeey naiad to Wool only. Cryogenic Wool hen a maxi- chained by ABM a afar ardrd nomad lhenneabsr at mew sales offices: the repiearnee el dMstm poach. Arty calm mum al canard of 0.2% by wetpht. Oder mamas The mass mfr wry* e boomer Tames. WA (Ng 418-1127 war reaped 10 an Paged delleWfby with the wool products mq Iwo master dl con - nrrxla wow twerone TM paws tang Walser, IN (eery 0542371 product contained herein shall be deemed ands, witch an mean an exploalon ha- WI mace& muetdement fa mabely lor NetanNNa,1X (105) 712 -e105 wand unless n.do In wrldne lo as wan and wan .Nosed to mood* sub- s ptAalerppdo trop Wag Memo, NC (100) 33405M tidily (30) digs d des wit is* gen. One. cane conditions of a pplatbn deny as or reasons* soma Iwo been and um es Were see oared, SAFETY MITI Folow good safety and 00110E: In no even era we be liable for discovered. T s naiber we not assume responsibility Ind.wbW hypMr peacdoee dub* wy male, Indeed, Incased a cones- for dry are or explosion Ward. handl* and ImaNYK o1 el products end Nree da mages Including, but not Ib dese vitae's. Take necessary pemu gar and to. loss d an*Wded pr or revenues, weu the ppopaa panned protective whew or not such demeges w calmed In equipment a mead. Read mesh) COMM ar (including dg space), mean- eat* data sleets and relied antic on V, str ict Oab11y or oegrvh I n addition, products before spedeealin artdbr we shah not be labs for wry loss wheadev- _ Ineteladon. sr caused by &potation of more good not CAM* For twain cryogenic applications LOCKW AM tl . netairyw• ,MOS• INSULATION iirr 3711 West Mil S tr eet • Waba IN 469924687 • Phone (888) TFIBE.R1 (834 -2371) Material Safety Data Sheet 11114„T, MSDS No.: 270 • Revision No.: 003 Revision Date: 06/18/03 Page: 1 of 2 Product name: Mineral wool Description: Synthetic vitreous fiber Supplier: Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121 Emergency # (Chem - Trec.): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) INGREDIENTS AND EXPOSURE LIMITS Ingredients: CAS Number: P EL: TLV: STEL: Slag wool fiber 65997 -17 -3 NE 1 fiber / cc NE Phenolic resin 09003 -35 -4 NE NE NE Polyvinyl alcohol 09002 -89 -5 NE NE NE Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. STEL = Short Term Exposure Limit. NE = None Established. NA = Not Applicable. PHYSICAL DATA Appearance: 2 x 4' x 4" sheets. Odor:Negligible Boiling Point: Not applicable. Vapor Pressure: Not applicable. Melting Point: Approx. 2400° F VOC Content: Not applicable. Evaporation Rate: Not applicable. Solubility in Water: Insoluble. pH: Not applicable. Specific Gravity: Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Not applicable. Flammable Limits: Not applicable. Extinguishing Media: As appropriate for surrounding fire; material does not burn. Special Fire Fighting Procedures: Soak cartons to help prevent the spread of fire. Use a self- contained breathing apparatus when fighting fires involving chemicals. Unusual Fire and Explosion Hazards: None known. REACTIVITY DATA Stability Stable. Hazardous Polymerization: Will not occur. Incompatibility: Strong acids. Hazardous Decomposition Products: Thermal decomposition products can be formed at temperatures exceeding 2000° F. Thermal decomposition can yield CO and CO Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: Acute: Eye, skin and respiratory irritation. Clwonic: Respiratory impairment. Routes of Exposure: Inhalation, Dermal. Signs and Symptoms of Exposure: Eyes: Mechanical irritation. Skin: Itching, irritation. kthalation: Nose, throat and upper respiratory tract irritation. Carcinogenicity: Slag wool has been classified by the IARC as Group 3 — Unclassifiable as to Carcinogenicity in Humans. Medical Conditions Eye, skin, and respiratory conditions. Aggravated by Exposure: C.7 V) N w 480 HI `TI • Saving Lives through innovation & education 1 Hilti Firestop Guide 2005 -2006 I 1 -800- 879 -8000 I www.us.hilti.com • � •^tar" Anvil Steel Pipe Nipples - Submittal Sheet 4 Z} ' ' AMnL • Anvil Steel Pipe Nipples (1)4 APPROVED AnvilStarTM offers a variety of Steel Pipe Nipples for the fire protection industry. Anvil's Steel Pipe Nipples are manufactured in accordance with ASTM Standard Specification A733- Welded and seamless carbon steel and stainless carbon steel and stainless steel pipe -- " nipples. Materials include black and hot- dipped galvanized finishes. Anvil® manufac- _ _ tures a wide range of stock pipe nipples in Ye" diameter through 8" diameter close through 72" inch length in half -inch increments. We also offer standard nipple packs ranging from one each (close to 6 ") and standard six packs which offer multiple counts of each. Cartons are packed with handles for easy carrying. fi PROJLC1 INi'ORIl9ATIoN: APPROVAL SIAMP: Project: undefined Date: undefined I Phone: undefined Architect / Engineer: undefined Contractor: undefined Address: undefined Notes 1: undefined Notes 2: undefined 3/05 -104 For the latest UUULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative IS'a1' Anvil Cast Iron Product - Submittal Sheet '= ANVIL . Anvil Cast Iron Threaded and Flanged Fittings APPROVED A offers the most complete line of Cast Iron and Malleable Iron Threaded Fittings in the industry. Our versatile range of fittings is designed to provide dependable, fire -rated service. Cast Iron Threaded Fittings, are manu- factured in accordance with ASME 816.4. They are UL listed and FM Approved and are available in sizes 1 /a" NPS through 12" NPS. Project: undefined Date: undefined ' Phone: undefmed Architect / Engineer: undefmed Contractor: undefined Address: undefined Notes 1: un Notes 2: un 3/05 - 100 For the latest UUULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative FIG. 92 Beam Clamps A N LStar - =,, L Universal C -type Clamp (Standard Throat) Submittal Sheet SIZE RANGE: 3 /8 and 1 /2° MATERIAL: Ductile iron, hardened steel cup point set screw and locknut. FINISH: Plain or Galvanized SERVICE: Recommended for use under rod installations with bar joist type construction, or for attachment to the top or bottom flange of structural shapes where the vertical hanger rod is required to be offset from the edge of the flange and where the thickness of joist or flange does not exceed 3 /4`. , _' APPROVALS: Complies with Federal Specification A- A -1192A (Type 19 & 23), WW -H- 171 -E (Type 23) and MSS -SP -69 (Type 19 & 23). UL, ULC Listed and FM Approved. HOW TO SIZE: Size of damp is determined by size of rod to be used. INSTALLATION: Fdlow recommended set screw torque values per MSS -SP -69 (See table on page PF- 212) FEATURES: • They may be attached to horizontal flanges of structural members in either the top beam or 1W bottom beam positions. • Secured in place by a cup - pointed Set Screw tightened against the flange. A Jam Nut is provided for tightening the Set Screw against the Body Casting. • Thru tapping of the body casting permits extended adjustment of the threaded rod. N c — F • Can be used with Fig 89X retaining dip for seismic applications. f E AT LEAST ONE �i 0 1 _ 1 OF Roo MUST in j BE UPOSEO D 4111. BODY I I 1111 : ee JAM •NUT fA - ii .1 NM SET SCREW 1' FIG. 92 Rod Size Set Screw Max Loads ■ A Size Top Bottom Weight C D E F G H 3 6- 34 500 250 .,� ..�. 0.34 lsh6 1tAs °h6 ".. 13A6 F 3A .�:� 1h v,. 1 h 1 h 950 760 0.63 1 11 1 1/2 1 1 1/26 2 • Maximum temperature of 450° F PROJECT INFORMATION: APPROVAL STAMP: Project: Date: I Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Refer to the Pipe Hanger Catalog for Additional Parts available on Anvil's Web Site www.anvilintl.com (11r)ANY111.1. Anvil• Pipe Hangers & Supports For the latest UUULC Listed and FM Approved pressure ratings, versus pipe schedule, REV. 03.03.06 go to www.anvllstar.com or contact your local AnvilStar representative FIG. 69 Pipe Rings A i Sthr" Fire Products Division of Anvil' International ( AFL Adjustable Swivel Ring, Tapped Per NFPA Standard' Submittal Sheet SIZE RANGE: 1/2" through 8" MATERIAL: Carbon steel FINISH: Galvanized A SERVICE: Recommended for suspension of non - insulated stationary pipe line. MAXIMUM TEMPERATURE: 650° F APPROVALS: Complies with Federal Specification A- A -1192A (Type 10), WW -H- 171 -E (Type 10) and MSS -SP -69 (Type 10). UL Listed and FM Approved (Sizes 3 /0 - 8'). FEATURES: • Threads are countersunk so that they cannot become burred or damaged. • Knurled swivel nut provides vertical adjustment after piping is in place. • Captured swivel nut in the 1 /2" through 3" sizes. y? :......: : A k i L. 1 ...4 NNE Pipe Size Max Load Weight Rod Size A 8 C F \ 92 0.10 2 2 1 F C B 3 /4 0.10 2 1 1 _.. 1 300 0.10 2 1 1 1 0.10 23/41 1 c. 74 + 1 0.10 3 /8 2 11/43 2 0.11 3 2 1 21/4 0.20 4 2 1 525 3 0.20 3 2 1 4 650 0.30 4 3 1 5 0.54 5 4 6 1,000 0.65 1/2 6 53/46 2 8 1.00 8 7 2' Project: Date: I Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Refer to the Pipe Hanger Catalog for Additional Parts available on Anvil's Web Site www.anvilintt.com Anvil® Pipe Hangers & Supports For the latest UUULC Listed and FM Approved pressure ratings, versus pipe schedule, (iir,14V,I,I REV. 03.03.06 w 002 go to ww.anvllstar.com or contact your local AnvilStar representative y HANGER PODS ii * ANVI L INTENN �TIlIN1E. INC. Fig. 146 . Continuous Threaded Rod Size Range: 1/4" through 1W Stocked in six, ten, and twelve foot lengths. Other even foot lengths can be furnished to order. Material: Carbon steel; rod threaded complete length. Finish: ❑ Plain or ❑ Galvanized. IIIIIIIIIINIIIIIIIIIIIID Maximum Temperature: 650° F. Ordering: Specify rod diameter and length, figure number, name and finish. Fig. 146: Loads (lbs) • Weights (Ibs) Dimensions (in) Rod Threads Max Load Weight Size A per Inch 650° F per Ft. 1 /4 20 240 0.12 Length 1 3/8 16 730 0.30 1 /2 13 1,350 0.53 5 /8 11 i 2,160 0.84 A 3 /4 l 1 0 ! 3,230 1.20 t 7/ 8 .-. 9 4,480 _........._..._.. _. 1.70 1 8 5,900 2.30 11/4 I 7 9,500 3.60 11/2 6 13,800 5.10 Note: Other rod sizes available upon request. Class 2 fit is available upon request. Pipe Hanger Submittal Sheet Project: Architect / Engineer: Approval Stamp: Date: Phone: Contractor: Address: Notes 1: Notes 2: Schedule -1 O® /Schedule -40® When you specify Allied Schedule -10 /Schedule -40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule -10 /Schedule -40 gives you the extra quality assurance you demand. Our Sch -10 (1 " - 8 ") pipe and Sch -40 (1"- 21/2") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Q Galvanized Pipe ,,1; t, spc ,r, c .,tto,is Schedule -10 /Schedule -40 product can be "hot -dip" NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR galvanized to meet FM requirements for dry systems 1n; mm ; In mm Lbs/Ft;kgim LbslFi;kglm - in accordance with the zinc coating specifications of 1" 1.049 1,680 2.05 1 ASTM A -123. 25 26.6 " 2.5 3.05 ` - 1 1.380 2.270 2.93 1 Superior Coating 32 35.1 4.36 4.36 - Our advanced formula mill coating offers a clean, 11/2" 1.610 2.720 3.61 1 durable surface. It is also paint -ready for custom 40 40.9 4.0 5.37 - color applications without special preparation. 2" 2.067 3.650 5.13 1 The internal surface of all Allied Tube & Conduit Fire 50 52.5 5.4 7.63 - 2 2.469 5.790 7.86 1 Sprinkler pipe products up to 4.500" in diameter is 65 62.7 85 11.73 - coated with our new Antibacterial Formula, "ABFII ". In scientific laboratory tests, ABFII proved to have n - 1u Specittu.tion, superior resistance to microbial colonization of pipe NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR walls, thereby inhibiting or possibly preventing the In; mm In; mm IbsIFt kg/m lbs/FZ kg/m - onset of Microbiologically Influenced Corrosion 1 1.442 1.810 2.525 7.0955 (MIC) upon installation and the first 25 flushes of 32 36.6, 2.7 3.75 - the fire sprinkler system.* 1 1.682 2.080 3.04 5.6570 40 42.7 3.1 4.52 - ® American Made 2" 2.157 2.640 4.22 4.5827 Meets "Buy American" requirement and is available 50 54.8 3.9 6.28 - through distributors in the USA, Canada, Mexico 2 2.635 3.530 5.89 3.5196 and Latin America. 65 66.9 5.3 8.77 - 3" 3.260 4.330 7.94 2.5550 ® Specifications & Approvals 80 82.8 6.4 11.82 - Schedule -10 /Schedule -40 pipe are in compliance 4" 4.260 5.610 11.78 1.6020 with the following: ASTM A -135, and NFPA 13. 90 108.2 8.3 17.53 All pipe products have a rated working pressure 5" 5.295 7.77 17.33 1.4874 of 300 psi maximum and also meet the stringent 125 134.5 11.56 25.80 - requirements for the following applications and 6" 6.357 9.290 23.03 1.0251 tests: 150 161.5 13.8 34.27 - • Welded Outlets 8" 8.249 16.490 40.15 1.8365 • Hydrostatic Pressure 200 209.5 24.5 59.75 - • Side Wall Rupture ® ® * See ABFII warranty t'a Ii tMsorner Service (800)0882- 6643Fax: (708) 339 -1806 TUBE& CONDUIT 16100xnitthrop. • Harvey, IL 60426 1 11350 Norcom Rd. • Philadelphia, PA 19154 I 2525 N 27th Ave. • Phoenix, AZ 85009 S5-3 7 % B I d J , �� fir. THIS [WILOM TO BE DESIGNED, PERMI[TTED, AND CONSTRUCTED AS A SEPARATE SET OF r • DRAVANGS - Bldq'E3 THIS BUILDING TO BE MOM PERMITTED, AND CONSTRUCTED AS wr A SEPARATE SET OF DRAWINGS gas mail Mot 10: r ���; —� - - or as LM Zfl IS oll Bldg C Publix REFER • 8HEET Ali 02 FOR COMPLETE LIFE SAFETY INFORMATION FOR BURMING C loop" THIS BUILDING TO BE [A Mo DESIGNED, PERNMO, �` AND CONSTRUCTED AS A SEPARATE SET Bldg F Of MAWINGS THIS BLIONG • M' MIONED, P8WED, /.iI %Jf ice`/ ep NEW, TENANT SPACE T# a 9"- " CONSTRUCTED AS SEPARATE SIET D A H&R BL OF DRAININGS . ....... .... ------- II - •fir �..• � , 1 �I ' �► �' � I � : f '� . �. � � , �. SPRINKLER HEAD LEGEND SW QTY rff nNISH TEMP K NOT Wd. I MODEL I SIN DESCRIPIM I t MAX COVERAGE I, J EX EXIST UPRIGHT BRASS 155 8.00 3/4 EXISTING EXPOSED / 130 SQ.FT, (THROUGHOUT) 25 PENDENT WHITE 155 8.00 3/4 WING M W-352 RECESSED 1' DROP (E-1 ESCUTCH),/ 130 SUT. 25 - TOTAL QUANTITY FOR THIS TENANT. ALL HEADS ARE QUICK RESPONSE. NOT TO SCALE $' -0 REMOVE EXIS17NO MAX MAX UPRIGHT SPRINKLER. BEAM CLAMP NEW I' ARA40W-R 0 30 NEW 1" 90 ELL ARMOVERS GREATER THAN rn (TYPICAL) 24"' SHALL. HAVE HANGER. I I ALL THREAD ROD (A.T.R.) 4 — OPEN WEB BAR JOIST - - - - -- � - -- — -- - -- - _ r - EXISTING 3/8' A.T.R. 4' AND SMALLER I a SPRIG -2— EXISTING 2 ,:, � _. &xv/ t �. e � FLOW SWITC11i A fit m GROOVE CHECK VALVE ^�� illy 4 e WALL MOUNT FDC C7- PIPE DRAIN TO EXTERIOR ONSPLASH BLOCK —\ TO SPRINKLER 8Y9MY INSPIECTOR81EST&D" C4iECK VALVE W/ ORM 00 VALVE AND GWES CONTROL VALVE W1 .00 �TAMPER8WfTCH � iIN18HED fl00R SUPPLY PIPE EXISTING RISER DETAIL NOT TO SCALE BRANCHLIN NEW I" DROP FOR 1 THROUGH 4' NOTE: ADJUSTABLE SWVEL RING �7 HANG MAINS TO TOP CHORD 6'-0' 10!• -O OF JOIST ONLY _--NEW I" x 3/4' R.C. BRANCHLINES MAY BE HUNG -- 2 FROM BOTTOM CHORD OF JOIST. 2x4 ACT CEILING 0 09 -__ -- _� _ __ -- _- - OUARTE=R POINT BE=AM CLAMP _- _.- -____- _ -- _ -,_ -- _�_--- �_----- - - - -__ SWING JOINT DETAIL HANGER 01 DETAIL 2 . . . NOT TO SCALE NOT TO SCALE � N 0 -:7 7 e2k GENE =RAL MOTES- rw ------- 1. SPRINKLER SYSTEM SHALL COMPLY WITH THE 2 Z EDITION OF NFPA 13. 0 PIOM be r�Jvlsed this review of pl ans submitted is a conmy re*w to mist ft contractor in m4 th SPRINKLER HEADS SHAL BE ORIFICE, STYLE AND TEMPERATURE TO MEET CODE. app k," fife sdety codes. This review is not int I to be a Mal approval of M subfnittM plans. it is the REFER TO SPRINKLER HEAD LEGEND THIS SKEET. -2 2 2 48 - 7-77 ( SP - mitracWs We reWsibility to ef►sure that the plans are in a p pl icable SYSTEM TEST SHALL BE WITNESSED BY CITY OF ZEPHYRHILLS FIRE M ARSHAL PRIOR 1 i --- t --- ---- - ordinances. In the event that further examination or TO ANY PORTION BEING CONCEALED. GIVE 4-8 HOURS NOTICE. inspe0on r■eals areas of non - compliance, it shall be ------ 9W cwtracWs sole revonsibiNty, at thew sole expv*e to HANGERS TO BE PER DEJAILS ON THIS SHEET. HANGERS SHALL BE SPACED IN - � - - -- - � - -- N - � bring those areas in omVllance. The City assumes no AC 2��. EPA 13 REQUIREMENTS. rewsibility for ft oonUactor's failure to be in oompliance ACC WITH Z' 2 vith al Wc" NFPA Codes and kA o(d"n ALL WORK SHALL BE COORDINATED WITH OTHER TRADES PRIOR TO FABRICATION. 6. 2* PIPING AND LARGER SHALL BE GROOVED SCHEDULE 10 WITH THREAD-O-LETS OR GROOVE-O-LETS. I ffi PIPING SHALL BE THREADED SCHEDULE 40. 2" GRIDDED PIPING SHALL BE GROOVED SCHEDULE 10 WITH THREAD-0-LETS. GRAPHIC SCALE i SUBMITTED PLAN(S) HAVE BEEN REviEwED7. ALL PENETRATIONS THRU FIRE RATED WALLS SHALL BE PROPERLY SEALED USING 0 4 8 16 BY ZEFHYRRILLS AL'S OffiC " E I I I DIft: UL LISTED METHODS AND APPROVED PRODUCTS TO MAINTAIN RATING OF WALL WE�mmj" FIRE= PRIOTECT'ION PLAN ��� °� (IN FEET) SCALE: 1/8" = l'-O" SCALE 1/8" -a V-0 FIRE PROTECTION FLOOR PLAN BLDG. PERMIT 9598 CAPSOO X8 T912 APPROVA• M13H DRAM BY- MBH SCALE. AS SHOWN DATE. 10/26/091 FP-1 Of I