Loading...
HomeMy WebLinkAbout09-9921 CITY OF ZEPHYRHILLS 5335 - 8TH STREET ' ' (813)780 -0020 9921 FIRE SPRINKLER SYSTEM PERMIT ..w. 7 HST. > `1 E ..fig a ¢:. "A $'`i, e :I:'.a 1 - .. .a' Permit Number: 9921 Address: 4241 SKY DIVE LN Permit Type: FIRE SPRINKLER SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE - SPRINKLER SYS Township: Range: Book: Proposed Use: COMMERCIAL Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: � ; arcel Number: 18- 26 -22- 0010 - 08600 -0000 Improv. Cost: 15,247.00 LL ':* w ` - �: p Date Issued: 12/22/2009 t t!, i.L?et■ ` Name: CITY OF ZEPHYRHILLS Total Fees: 830. ■ • Address: 4241 SKY DIVE LN Amount Paid: 83 ►.0"" et_ ZEPHYRHILLS, FL. 33542 Date Paid: 3/02/28 0 Phone: Work Desc: SPRINKLE ' SYSTRM INSTAL ' ION -FEE WAIVED AAA - - - • • V N e' 1 s 0.00 - IN' - I ■• N F 155.00 VIEW FEES 150.00 FIRE PLAN REVIEW FEES 200.00 = - ECTION FEES 175.00 FIRE SPRINKLER SYS 50.00 ei05-e- a ' -2% ( (efire t - 3° r i t U S ‘c if ' 5 1(-\11\1 1 ' , \.5 IF I' . ti /1 r iti ri, i l/ IV •r,_ , 3 —Z `\t ab IDA4 I = - RE FIRE ACCEPTANCE Final Chapter 633, Florida Statutes, authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees, and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of $100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." 4 _ it esF y-ApP k. CONTRACTOR SIGNATURE ` ri 1 - 7 - IC R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT - Fire Marshal Office - 813- 780 -0041 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780 -0020 9921 FIRE SPRINKLER SYSTEM PERMIT O ,t • e „ , : . i m 7T , s . ,`e$ 'q''' - - :i 'ma ° 1 § s . S a s ,' °s i d a Z4 a" Permit Number: 9921 Address: 4241 SKY DIVE LN Permit Type: FIRE SPRINKLER SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE - SPRINKLER SYS Township: Range: Book: Proposed Use: COMMERCIAL Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 18- 26 -22- 0010 - 08600 -0000 Improv. Cost: 15,247.00 '" 73 Date Issued: ` Name: CITY OF ZEPHYRHILLS Total Fees: 405.001 Address: 4241 SKY DIVE LN Amount Paid: 405. ZEPHYRHILLS, FL. 33542 Date Paid: 12/22/2009 Phone: Work Desc: SPRINKLER INSTALLATION -FEE WAIVED v 2A6;4, ..7=7:777717.:r!,' p ;V s 4 ate AAA I • •N N FIR -` NKL - 100.00 I TI *NJ' 155.00 FIRE PLAN REVIEW FEES 150.00 ... , ._ s;;., a a.• , . C , s "r *,._ ... , 3 .s. . `"5u'o ..,`.'' 3 �'ry'sb g• IRE 1' TE FIRE ACCEPTANCE Final Chapter 633, Florida Statutes, authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees, and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of $100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RE ORDING YOUR OTICE OF COMMENCEMENT." 4,„ i - _.rl* ji CONTRACTOR SIGNATURE r g I _ IC R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT - Fire Marshal Office - 813- 780 -0041 7 b , 813 - 780 -0020 City of Zephyrhills "Fire � ) 1 3' ;�- � X-813-780-0021 trqq 2/1 Permit Application ► O sv N& • Date Received _ ., 0 . �._ P Cwrtactfor Permit L' lf� i•S��/11 'I Owner's Name I 46/7y OF ,..c1' L*ie/i /X -S I Owner's Phone Number l 1 1 1 Owners Address ` Fee Simple Titleholder Name Titleholder Titleholder Phone Number I ( 1 1 l Fee Simple Titleholder Address Lot # ! & °��., -: � v*� ° .°sue . ,e � sa'mfsfi a :',''"� ... _.,. � o-. .. •.. >rkxa t. � ,r .��.� v.?. o sz;. ,.. .,s , _., �w .. , - .. 'S:a` ..M , ._...,..d.,,,. .'�'S" =. ,( � . ,`� ..H�: Yn�e;t°;x ems. <. „ i:� : Job Address . 1 �< y d) 1 V � � cti ZP°l �� r G, • I l ` 1 J I Parcel # 1 Sub Division , . .. _ n Bio-Hazard Waste Storage - ANNUAL n Fumigation Tent 0 Comm Exhaust Kitchen Hood/Duct n Hazardous Material (Tier II or RQ Facility) ANNUAL El Controlled Bum 0 Hood Installation n Emergency Generator < 30 kw n tura LP/NaI Gas - installation n Emergency Generator> 30 kw 1 LP/Natural Gas - ANNUAL Sal: n Are Protection Maintenance - ANNUAL n Places of Assembly- ANNUAL z ,bens) ] puler Sprinkler ED ❑ ❑ ❑ I Recreational Bum Fire Alarm 0 ❑ ❑ ❑ I ( i I S pa re Hood Cleaning in ❑ ❑ ❑ I I Eg'S System Installations Hood Suppression n ❑ ❑ ❑ I I n Standpipes (Sprinkler Sys) n Fire Alarm Installation n Torch Roofing/Tar Kettle M Fire Pumps n Waste lire Storage ANNUAL Fire Works Flammable Application- ANNUAL ez2y 7 .15D I Valuation of Project Fuel Tanks IN Other: . ' :8ta: ,.!s :..r •ew. z, ,.�iu ;sr « �±+ a.. : ;.n...,.a_.,<:;.44..K A� ..n- ;�hx¢, awm -r-- ..�.,e. - .-...r K..'... • w • _�':`° .,.* a sac' - u.;x c?..i.s,.a. ; :n v,x .,wr 'u �t- &:c . >%c? ,,. b�••5:n.'„ r. Contractor ,, ,4 , Company ,. A F r€. - CinOAss 125-2 Signature C, VV Registered *AM Fee Current Ilro__ Add = ss ; 5 0 s - 6 t t. 0 ril'Fs:24 P u -f • — rp . 7L. 1 License # i 4 10 4 9-7 3 a a o 1 o o7I ELECTRIC • Company Signature Registered Y/ N I Fee Current 1 Y / N Address I I License # I PLUMBER Company Signature Registered Y/ N I Fee Current I Y/ N i Address I I License # I MECHANICAL Company Signature Registered Y/ N 1 Fee Current 1 Y/ N I Address 1 I License # OTHER • Company ��T•a��; ; • AJ vt Signatu : Registered Y / N Fee Current Y / N ilA Ad ress wG pY /� �Etju .r..s&I /i License # $' a I • • •7Q0 Direction " All out application completely. Owner & Contractor sign back of application, notarized (Or, copy of signed contract with owner) If over $2500, a Notice of Commencement is required (Mechanical work over $5000) Supply two (2) sets of drawings with applicable documentation Allow 10 -14 days for review after submittal date. Parcel # - obtained from Property Tax Notice (http:/ /appraiser.pascogov.com) . NOTICE OF:DEED RESTRICTIONS: The undersigned understands that this permit may be subject :to - "deed ":restrictions" .. whiob may be more restrictive than County regulations. The undersigned assumes responsibility for-compliance•with any applicable deed restrictions. UNLICENSED CONTRACTORS AND - CONTRACTOR RESPONSIBILITIES: If the owner has hired - :a ~contractor or contractors 19 undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may :apply for the intended work, they are advised to contact the Pasco County Building Inspection Division — Licensing Section at 727 -847- 8009. Furthermore, if the owner has hired . a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as 'the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled - to permitting privileges in Pasco County. CONSTRUCTION LIEN LAW (Chapter713, Florida Statutes,as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law — Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner ", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S /OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If 1 am the AGENT FOR'THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORN BEFORE RECORDING Y• R NOTICE OF COMMENCEMENT. FLORIDA JURAT (F.S. th7.03) / ,�f — OWNER OR AGENT i,_ • _AL .1 . . NT - - - CORA Syy bs��. and sworn to (or affirmed) b� me + i � Sub y . „ (or affirmed) before me this , IC> ' by I O L i -. W /� ) �` , by '1: A ■ _ ii V s/are personally known to me or has/have produced Who is/are persona knov 0,to me or ha - ve produced A as identification. iv , as identification. i � ��, . / h._ ' , • J . / / Notary Public /h./ k' `ilex Notary Public Co mission No. Commission No. 1, 1 A.)4a Ri eitiche4as A, Woe 'i r.�,h4ie�s Name of Notary typed, printed or stamped • Name of Notary typed, prior stamped UNDA RI r ' ` , 528 E '°.'1 Commission DD 808 DD 8 July Expires July 24, 2012 -- Expires BadedT mT,oyFaiiMIssan 8 7919 ' ;t`;+, •' Bo Expire Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (81 3) 780 -0041 Kerry Barnett Fax (813) 780 -0044 E-mail: k.barnett@fire.zephyrhi I ls. fl .us Plan Review #: 09 -110 Project: Fire Sprinkler Installation Number of Pages: 1 December 21, 2009 I have received and reviewed the plans for the installation of a fire sprinkler system located at 4241 Sky Dive Lane and will allow the project to move forward. Please note that this review does not eliminate any further requirements as the project continues moving forward. By receiving permit, contractor acknowledges to comply with the items listed below. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. 1. Provide license to show company is certified to install the underground. 2. Provide spec /cut sheets on all (sprinkler heads, DCVA, FDC, piping, valves, etc...) this was noted on the previous review. 3. Tamper switches required on double backflow assembly. 4. FDC Sign to be posted at FDC location. Sign to be minimum 6' high with 6" red reflective letters "FDC" on white background. 5. Thrust blocking shall be used on underground. Blocking shall be formed in a wedge style. 6. Riser shall not be obstructed. Owner may want to install a chain link fence around riser to prevent obstruction and /or tampering. NOTE: #1 and #2 are required prior to work being started. Sheets can be faxed to number at top of this comment sheet. 2 Inspections Required: I. Underground Flush (Contractor shall provide all equipment to conduct flush in accordance to the code. Flush shall be conducted through a large diameter hose with a drain bag at the end. The bag will allow the water to be checked for sediment. 2. Underground Pressure Test 3. Pressure test on sprinkler system 4. Acceptance Test (in conjunction w /fire alarm system) A 40,yiltfai ' / EETT, FIRE MARSHAL ** *Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Fire Chief Keith Williams Bus (813)780 -0041 Fax (813)780 -0044 FIRE SERVICE USER FEES • Occupancy No.: , Plan No.: 1 . - //d t Contractor: ,,, 14,/e4G/7 /!iz/�G 'j Business Name: S // Y 1il/e C -r Billing Address: 2 2 Sco�c . . Business Address: 4 � � 1Y! F�s ,I/ ; /, � � - 6°4 Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES _ INSPECTION FEES PERMIT FEE FALSE ALARM FEE Site Plan N/C — Annual N/C ,�ISprinkler 11 1st Alarm N/C Muni - Family /Commercial .06 sf — 1st Re- inspection N/C f Standpipes -�: � ■ 2nd Alarm N/C (Minimum Charge $25.00 _ 2nd Re- inspection 5100 V Fire Pump 550 1 3rd Alarm N/C fl Plan Revisions DBL _ 3rd Re- inspection $250 , Hoods 550 11 4th Alarm $100 4th Re- Inspection $500 . Fire Alarm $50 . 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until 1 LP Gas 550 1 6th Alarm $200 0 - 25 Heads $50 violations corrected) , Natural Gas $5D . NON COMPLIANCE $15D 6 plus Heads DD SPRINKLER SYSTEM 111 Fuel Tanks- per tank $50 STANDPIPE SYS r,d, Hydro Undergrounds 1 , Sparklers 5100 Per Riser 550 Hydrostatic Test rsystem , Fire Works $500 FIRE PUMP lAcceptance Test OP per system , Camp Fire 525 0 Per Pump 5100 11 Hydrant Flow I*• , Controlled Bum 5100 FIRE ALARM SYSTEM , Hood/Duct $50 — _ 0 - 25 Devices $50 _ FIRE ALARM SYSTEM "Place of Assembly 550 Annual 26 plus Devices $100 — System Acceptance 550 , Fire Protection $25 SUPPRESSION SYSTEMS _ Recall Acceptance $50 11 Flammable Application 550 Annual Wet CO2 Other $50 _ OTHER ,Waste Tire Storage 550 Annual Dry 550 _ Fire Wall /Smoke Wall $15 per wall , Generator < KW $100 $5D LP Gas $50 $25 pertank , Generator KW 150 _Natural Gas 525 per system , Bio-Hazard Waste $100 Annual KITCHEN EXHAU –.– $25 Fumigation Tenting $50 Hood/Ducts $50 _ Tent 105(10' or greater 515 per tent . Torch Pot/Applied 550 OTHER _ Fire Pump $45 11 Haz. Materials .1 annual _ LP Installation per tank $50 ` Fire Suppression $30 04l4( — Fuel Tank Installation $50 — System Acceptance — (Per Tank) $50 _ Exhaust Hood/Duct $30 0 Natural Gas installation $50 _ Re- inspection DBL (Per System) (other than annual) _ 0 Spray Booth 550 fl Inspection scheduled DBL and cancelled less than _ _ 24 hours _ Construction Insp. N/C — Emergency Vehicle Aci $50 _ ,,.4 f FALSE ALARM PLANS TOTAL ri% INSPECTION TOTAL PERMIT TOTAL /N .,"" TOTAL GRAND TOTAL Comments: // Date: f 2 / InsA ctor: / _ ., v' .� :krmfb Rif �� eat City of Zephyrhills: i 10‘,'"' Building Department Phone: (813)- 780 -0020 Fax: (813)- 780 -0021 TO: donna FROM: jackie k FAX #: 813 - 882 -3703 FAX #: DATE: 12 -11 -09 # OF PAGES including cover sheet: 3 i € 1 # 1 € # MESSAGE: donna per our phone conversation I am faxing over to you the rejection comment sheet given by kerry the fire marshall. E # Jackie i € r # € 1 7 # 9 € f 1 € € € # 1 1 E # 3 1 1 1 E # 1 € # # E 1 € 1 # € € 1 E E E # € E # E P. 01 /0 TRANSACTION REPORT DEC /11 /2008 /THU 00:19 PM FAX(TX) # DATE START T. RECEIVER COM.TIME PAGE TYPE /NOTE FILE 01 DEC /11 00:18PM 818138823703 0:01:08 3 OK G3 9800 City of.Zephyrhills: i r, Buildin g Department b ..,,_: w,_, :.........:......n_ Phone: (813)- 780 -0020 :. =. >. • Fax: (813)- 780 -0021 TO: donna FROM: jackie • FAX #: 813- 882 -3703 FAX #: DATE:12 -11 -09 # OF PAGES including cover sheet: 3 MESSAGE: donna per our phone conversation I am faxing over to you the rejection comment sheet.given by kerry the fire marshall. Jackie • Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire l4arshal Bus (813) 780 -0041 Kerry Brett Fax (813) 780 -0044 E -mail: kbarnettna Plan Review #: 10 -014 Project: Fire Sprinter Revision Number of Pages: 1 plus Packet Itch 1, 2010 I have received and reviewed the plans for the fire sprinkler installation located at 4241 Sky Dive Lane and will allow the project to move forward. Please note that this review does not eliminate any further requirements as the project continues moving forward. By receiving permit, contractor acknowledges to comply with the items listed below. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. 1. Installation shall be in accordance to NFPA 13, latest edition. 2. Underground shall be flushed and witnessed by Fire Marshal. 3. Underground shall have thrust blocking. 4. Tampers are required on double backflow preventor. 5. 5" Storz shall be a 30 degree turn down, drawing shows it straight. 6. An FDC sign shall be mounted on a post by FDC. Lettering shall be 6" red reflective letters on white background. 7. Cut sheets /details /spec sheets required on double backflow, underground pipe and connections, valves, tampers, sprinkler heads, etc.. This shall be provided before the first inspection is completed. Fiona Required: 1. Underground Flush 2. Underground Pressure Test 3. Sprinkler Pressure Test 4. e Test in conjunction w/Fire Alarm 49 KERRY • ' TT, FIRE MARSHAL ** *Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Fire Chief Keith Williams Bus (813)780 -0041 Fax (813)780 -0044 FIRE SERVICE.USER FEES Occupancy No.: Plan No.: /D o/9 Contractor: AAA Fyp f/e Business Name: S'XY /)r1 £ Billing Address: 8'S o 7 , Su i nr e.S� Business Address: t i24// , '7 , 4<, -- 2..A...) j p P2 334341 Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES _ INSPECTION FEES PERMIT FEE _ FALSE ALARM FEE _ Site Plan N/C _ Annual N/C I7 Sprinkler $50 _ 1st Alarm N/C Multi- Family /Commercial .06 sf — 1st Re- inspection N/C Il Standpipes $50 2nd Alarm N/C (Minimum Charge $25.00 _ 2nd Re- inspection $100 , Fire Pump $50 3rd Alarm N/C — Plan . ns DBL 3rd Re- inspection $250 . Hoods $50 _ 4th Alarm $100 4th Re- Inspection $500 , Fire Alarm $50 _ 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until 1 LP Gas $50 _ 6th Alarm $200 0 - 25 Heads $50 violations corrected) II Natural Gas $50 NON COMPUANCE $150 26 plus Heads SPRINKLER SYSTEMS , Fuel Tanks - per tank $50 STANDPIPE SYSTEM Hydro Undergrounds $45 , Sparklers $100 El Per Riser $50 Hydrostatic Test $65 per system , Fire Works $500 FIRE PUMP Acceptance Test $45 per system , Camp Fire $25 El Per Pump $100 Hydrant Flow $75 , Controlled Bum $100 FIRE ALARM SYSTEM , Hood/Duct $50 0 - 25 Devices $50 _ FIRE ALARM SYSTEM 11 Place of Assembly $50 Annual 26 plus Devices $100 — System Acceptance $50 ' I Fire Protection $25 SUPPRESSION SYSTEMS _ Recall Acceptance $50 , Flammable Application $50 Annual Wet $50 _ OTHER , Waste Tire Storage $50 Annual Dry $50 _ Fire WalUSmoke Wall $15 per wan , Generator < KW $100 CO2 $50 — LP Gas $25 per tank , Generator >30 KW 150 O ther $50 _ Natural Gas $25 per ■ Bio-Hazard Waste 5100 Annual KITCHEN EXHAUST _ 1 Fumigation Tenting $50 El Hood/Ducts $50 _ Tent 10'x10 or greater $15 pertent , Torch Pot/Applied $50 OTHER _ Fire Pump 545 ! Haz. Materials i p $100 Annual LP Installation per tank $50 _ Fire Suppression $30 ►.Q 1) 11Xyrb 7 50 Fuel Tank Installation $50 _ System Acceptance (Per Tank) $50 Exhaust Hood/Duct $30 El Natural Gas Installation $50 Re- inspection DBL (Per System) (other than annual) _ 0 Spray Booth $50 fl Inspection scheduled DBL _ and cancelled less than — _ 24 hours Construction Insp. N/C _ Emergency Vehicle Ao $50 FALSE ALARM PLANS TOTAL INSPECTION TOTAL r h — PERMIT TOTAL ) TOTAL GRAND TOTAL 1 L 1 - 7 -c • Comments: - ..h • . Date: 3 1 t \ 10 Ins�ctor. ht N� th — r Sky Dive City Drawing Date: 2/17/10 14 :30 HYDRAULIC DESIGN INFORMATION SHEET Ati . f hr Job Name: Sky Dive City 4 Location: 4241 Sky Dive Lane Zephyrhills, FL Drawing Date: Remote Area Number: 2 Contractor: AAA FPS, Inc. Telephone:813.886.8869 8502 Sunstate Street Tampa, Florida 33634 Designer: RTS Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Wood Occupancy:Light Reviewing Authorities:Fire Marshal SYSTEM DESIGN Code:NFPA 13 Hazard:Light System Type:WET Area of Sprinkler Oper. 400 sq ftl Sprinkler or Nozzle Density (gpm /sq ft) 0.100 1 Make: TYCO Area per Sprinkler 330.0 sq ftl Model: TY -FRB Hose Allowance Inside 0 gpm 1 K- Factor: 8.00 Hose Allowance Outside 250 gpm 1 Temperature Rating: 155 CALCULATION SUMMARY 2 Flowing Outlets gpm Required: 316.0 psi Required: 29.6 @ City Supply WATER SUPPLY Water Flow Test 1 Pump Data 1 Date of Test 11/20/2009 1 Rated Capacity 0 gpm 1 Static Pressure 77.0 psi 1 Rated Pressure 0.0 psi 1 Residual Pres 61.0 psi 1 Elevation 0 1 At a Flow of 1240 gpm 1 Make: 1 Elevation 2'0" 1 Model: 1 Location: 1000 ft South of Site Source of Information: AAA Fire Protection Services, In SYSTEM VOLUME 94 Gallons Notes: Covered Concessions Area Proof lj 1 :.00u o ° ai 000 to a P. a 0 o o - - - - -- — a 1 c O LL 0 _ E 4 to a a0) 00 , 0aio — dj as E'.2 $2 7 cd cu CL CC CC , 0 0 F00 � 0 a) a) 7 o�� 2.0 1 I F EE. - 1 -- I - u) gain 1 a1 I I I I CO a0) o)a 1 0 _ in I j I _ 1 { a) N 1 , , Q ' , 1 , ... O t%= 0 > I j a)> L� EE a W 1 CC a cn c� c4 = ! 1 1 1t u) u) i 000 a) I N 1 1 N CA .. E. . y O9 T + - 1 - N N cn 0 E N 1 1 0I -ea r O ,- O - O O 0 ...= 65 2 i 0 G h J O N a) -I .. > L m - Ne 00 ci) �, a .0 > a E N . r O N a) a) 4 -3 CA.:1-NCC -- — - • 1 T 0 N p co co �O O N Sky Dive City Drawing Date: 2/17/10 14:30 HYDRAULIC CALCULATION DETAILS HYDRAULIC FLOW LOSS QTY DESCRIPTION LENGTH C ID gpm psi TOTALS Hydr Ref W Required at Hyd Area 2 66 19.4 psi 1 4" Grvd 90 Ell 10' 120 4.026 66 0.0 1 Pipe 4" 10x21 10' 120 3.260 66 0.0 1 4" Grvd Shotgun Valve "90" 21' 120 4.026 66 0.0 1 4" Flngd Butterfly Valve "A" 12' 120 4.026 66 0.0 Elevation Change 10'0" 4.3 Hydr Ref R1 Required at Base of Riser 66 23.9 psi 1 Pipe 6" DIx18 Cl 350 120' 140 6.338 66 0.0 3 6" MJ 90 Ell 42' 120 6.065 66 0.0 1 6" Flngd Back Flow Valve Watts "709 CHART LOSS 66 3.2 1 Pipe 6" DIx18 Cl 350 40' 140 6.338 66 0.0 1 6 "Gate Valve Kennedy "4071" PIV 3' 120 6.065 66 0.0 1 6" MJ Tee 30' 120 6.065 66 0.0 Fixed Flow Outside Hose Stream 250 gpm 1 Pipe 6" DIx18 Cl 350 1000' 140 6.338 316 2.5 Hydr Ref R2 Required at City Supply 316 29.6 psi Water Source 77.9 psi static, 61.9 psi residual @ 1240 gpm 316 gpm 76.6 psi SAFETY PRESSURE 47.0 psi NOTE: Water Source has been adjusted to include a change of elevation of 2'0" flow test to point of connection Available Pressure of 76.6 psi Exceeds Required Pressure of 29.6 psi This is a safety margin of 47.0 psi or 61 % of Supply Maximum Water Velocity is 5.3 fps Sky Dive City Drawing Date: 2/17/10 14:30 Page 3 FITTING NAME TABLE ABBREV. NAME C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee ✓ Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. K FACTOR Flow factor for open head or path where Flow (gpm) = K x - \/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf /ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q /C) ^1.85 / ID ^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q ^2 /ID ^4 Pn Normal pressure (psi), where Pn = Pt - Pv NOTES: - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Sky Dive City Drawing Date: 2/17/10 14:30 Page 4 NODE ELEVATION SPRINKLER PRESSURE ACTUAL MINIMUM ACTUAL NUMBER K- FACTOR FLOW FLOW DENSITY (FT) (GPM /(PSI ^1/2)) (PSI) (GPM) (GPM) (GPM /SQ.FT) 50 10.00 8.00 17.0 33.0 33.0 0.10 51 10.00 8.00 17.0 33.0 33.0 0.10 60 10.00 17.1 61 10.00 17.1 B1 10.24 19.4 B2 10.24 19.4 W 10.24 19.4 Max velocity of 5.25 occurs in the pipe from 61 TO 51 Sky Dive City Drawing Date: 2/17/10 14:30 Tyco Fire Products Page 5 HYD. Qa DIA. FITTING PIPE Pt Pt REF "C" TYPES FTNG'S Pe Pv * * * * * ** NOTES * * * * * ** POINT Qt Pf /ft TOTAL Pf Pn PATH 1 FROM HYDRAULIC REFERENCE 50 TO W (PRIMARY PATH) 33.00 1.610 1.13 17.0 17.0 K = 8.00 50 C =120 0.00 0.0 0.0 33.00 0.041 1.13 0.0 17.0 Vel = 5.25 1.682 3E 47.80 17.1 17.1 60 C =120 1T 24.75 -0.1 0.0 33.00 0.033 72.55 2.4 17.1 Vel = 4.81 3.260 10.03 19.4 19.4 B1 C =120 0.00 0.0 0.0 33.00 0.001 10.03 0.0 19.4 Vel = 1.28 33.02 3.260 1E 4.70 19.4 19.4 B2 C =120 9.41 0.0 0.0 See PATH 2 66.02 0.005 14.11 0.1 19.4 Vel = 2.56 W 66.02 19.4 K = 14.98 PATH 2 FROM HYDRAULIC REFERENCE 51 TO B2 33.02 1.610 1.13 17.0 17.0 K = 8.00 51 C =120 0.00 0.0 0.0 33.02 0.041 1.13 0.0 17.0 Vel = 5.25 1.682 3E 47.56 17.1 17.1 61 C =120 1T 24.75 -0.1 0.0 33.02 0.033 72.31 2.4 17.1 Vel = 4.81 B2 33.02 19.4 K = 7.50 UNITS - DIAMETER (INCH) LENGTH (FOOT) FLOW (GPM) PRESSURE (PSI) ❑ N / I 0 +10 61 +10 - ❑ 0 -11 2 1 -9 2 -10 N �2) EC HSW PROVIDED FOR PROTECTION 1 N 5 I ( OF COVERED WOOD DECK ATTACHED 1 -21 1 Q I I �, �, ❑ o N SPECTOR'S TEST VALVE TO BUILDING - - NCO N CO N C.O N c 0 N CO CO N CD CO O O 5 r �O o 3 CD 3 CD I 3 ° 3 12 ° 12 ❑ ❑ ❑ ❑ ❑ � 9 1 NCO E _ �o I I _ I r❑ I [ : 4] _ 2 � W 4i r , lO N o CN 12 12 12 12 z 12 12 z� O * I 12 I, 4' - 10' 4' - 10" — 5' -0 1/8' J 5' -0 1/8' -- --I- -- 4' -11 b „ -0 1/8' - - -- 4' -11 1 /2' 5' -�1 I 4' -4' CF) 5'-0 1/8' Li I m N N m C'4 ID m N M m N m N m N h w < o a N N N w I .- > _ j O wo w OVERHEAD DOOR COILS AND _ DOES NOT OBSTRUCT FLOOR ° 2 6❑ I I SPACE 1 1 1 1 m 8'C” TALL WALL 3RACED -- - ° 5' -6 1/2 N N I 1 N I N I N I N I I I � Ln � Ln I � LC) r- Ln I r- L0 Ln � I — 1 N C. r I � I O Q o r � o o r o r• I o �- o � � 12 12 12 12 1 _12 1 2 O 12 J O 12 N o0 12 I 12 W � J � J - J - J I I I I � M J a- a O j Q) o N O o N O o 0 0 0 0 o o o N O N o� N NEW HYDRANT AND NEW STORZ CONNECTION /B DEVICE SHALL BE LOCATED WITHIN 50' OF ONE ANOTHER (GC TO COORDINATE LOCATIONS). ❑ O 0 1 s-- N �- N ( I o o M Q) l/ 1 0 X r N N N N I N N -- I N N ( N iC) N - r .- r r D - �� r .-- • L, U r- .- �- 0 O � U �_ I T I T T I I Z � OVERHEAD DOOR COILS AND I a DOES NOT OBSTRUCT FLOOR o SPACE I I � J _ _ I _ _ I _ Z 1 1 0 N I Q w , N N N N N c N N N N N W F ca5 L I cV v Z Q N N Q N N N N Q N N Q N N Q N N ( Q N N Q N N ( Q N N Q N N a Y to Q `_ I I I I O' " I Z W , p, �- N r- N r- N c- N I N N N c- N 0 U 4 M �J c7S 11 V Q o m Q I Z_ � O o I W W� m L S 0 'V 0 1 o a � � X 12 J � � X 12 J L 12 J 12 _12 ` 112 X 12 12 J 12 12 J oW Z' 0 i x o I I I - -- - In X Ix LU Li ❑ Al '� �`� AZ '� o�� A 3 �` ��' '` ��' I r�Ais o (AGE AREA '` �� `` �� `` o�� I r B '` �� ❑2 � N N O/ \ \ N NI `\' O N , N 0 - - - - N `� N `v O� Q rn CV L J sue- cV r - Cv J - �- N / ❑ N r N N � i1' -9 3/4" 3 a ° 3 ° ° ° ° ° ° ° ° 3 3 ° ° 0 3 3 �° 3 C° 3 3 3° 0 -4 9 -8 9 -10 1- 8- 0 _ 09 1 2 -2 ' 7 -10 9- 1 2 3 - 6 - 10 1 2 9 - 4 - 9 1 2 5 - 2 - ° A6 I A5 ❑ =A2 .. .. -- -� . . -- — ' ELL i — -- ' _ „ 4x3" GRWD REDUCING COUPLING . SYSTEM ` - - STAGE - 16 HIGH RAISED FLOOR CONSTRUCTED OF (>i -x 0) 4 FIRE RISER W \ NON COMBUSTIBLE METAL STUDS AND FIRE RATED 4" SWITCH PLYWOOD AS DECKING. NO COMBUSTIBLE MATERIAL WILL ( R NG W BY O THERS) � to Q 1• BE STORED WITHIN THIS CONCEALED SPACE. NO SPRK'S 6 HEAD SPRINKLER 5 PER NFPA 13. 8.15.16. ❑ CABINET WITH HEADS FROM BRANCH LINE a J Q) -- PRPOSED 24' WIDE 1 GRAVEL DRIVEWAY NEW EIRE HYDRANT P20MDFD .BY an-a-, ZEPHRYHILLS UTILITIES DEPT.. NEW HYDRANT AND NEW STORZ CONNECTION /B DEVICE SHALL BE LOCATED WITHIN 50' OF ONE ANOTHER (GC TO COORDINATE LOCATIONS). F_ I I V Al AAA FPS, Inc WORK TO START AFTER GATE VALVE a WITH UG TO DDVC AND UG TO BLDG SERVICE RISER 2 6' PIPE BOLLARDS BY OTHERS 4' CHECK VA WITH 5" 30 DEG STORZ FDC ON DISCHARGE OF BACKFLOW DEVICE. UG SHALL BE DR -14 FOR FD PUMPER PRESSURES AND BLDG CONTROL VALVE O SHALL BE DELETED FROM RISER. - - - - - - -- -� � --- --- -------------------------------- /,� 15'0 I � ` ` 1 5' STORZ FDC MOVED TO 120' 6' DR 14 UG SUPPLY DISCHARGE OF BACKFLOW DEVICE FROM BACKFLOW DEVICE 1 L-------------- 6' WATER MAIN EXTENSION 5' BACKFLOW DEVICE PER AHJ STANDARDS. 4' RISER LOCATION NEW HYDRANT, NEW TAP BACKFLOW DEVICE AND STORZ CONNECTION AND NEW GATE VALVE TO BE LOCATED WATHIN 15' OF WESTERN EDGE OF (BY CITY OF ZEPHRYHILLS THE EXST PAVED ROAD SURFACE.❑ Z UTILITES DEPARTMENT) i a / WATER FLOW SUMMARY: / a TEST DATE: 11 -20 -2009 PERFORMED BY. AAA FPS, INC. / ` LOCATION: 1,000 FT FROM SITE / I STATIC = 62 PSI RESIDUAL = 40 PSI FLOW = 1060 GPM / REDUCED SITE PLAN NO SCALE / UNDERGROUND FIRE PROTECTION PIPING SHOWN ENTIRELY FOR THE PURPOSE 11. BACKFLOW PREVENTOR PER AHJ STANDARDS D [BACKFLOW PREVENTOR DETAIL NIO SCALE SMOOTH BORE CORROSION RESISTANT OUTLET GIVING FLOW EQUIVALENT TO ONE SPRINKLER. INSPECTOR'S TEST (WET P IPE NO SCALE I STORZ FDC :CK VALVE 42 [UPRIGHT AND WRENCHES ALARM BELL " (WIRING BY OTHERS) SUBMITYED PLAN(S) HAVE BEEN REVIEWED -- 5" STORZQ 13Y ZEPH E YRHILLS - I: MARSHAL'S OFFICE - DELETED - Date: 4 CHECK VALVE EXTERIOR WALL SHOTGUN RISER CHECK 1" BALL VALVE SET VALVE WITH (2 ) Q2 AT 5' -O" A.F.F. 't� viewer: - PRESSURE GAUGES AND -DELETED - e/ DRAIN ASSEMBLY • GR. BUTTERFLY VALVE 6'x4' REDUCING -DELETED - � Q ' ease be advised this review of plans submitted 13 1ti COUPLING GALVANIZED NIPPLE �t (IQry r$YIeW t0 assist the contractor I }� BASE OF RISER o GALVANIZED 45' ELL licahle f ire sa fety codes. This review is not intended . app rovai of tlW2 Submitted plans. It ; the • to be a final app pla ns are In 6" UNDERGROUND. SEE cconvactoes sole responsibility to.eAVICe s, l REDUCED SITE PLAN FOR W'Aplete compliance with all a pp licable NAPA co des and CONTINUATION. local ordinances. In the event that further xam t shalt f site inspection reveals areas of nor comp 6 PRESSURE RATED the contract Of S sole responsibility, at q4s Sole expense t4 A UNDERGROUND SUUPLY RISER DETAIL z� bring those areas in compliance. The Cray assumes no NO SCALE responsibility for the contractor's failure to be in com 1�jjh all applicable RFPA Codes and 10" n CHECK VALVE AND STORZ CONNECTION DISCHARGE SIDE OF BACKFLOW DEVICE BEAM CLAMP STEEL A.T.ROD 0 I HANGER RING HANGER DETAIL NO SCALE 0 C� 4.) r N � CID w w E 4; 1:22"��� w � 0 0 Lei a� N r a 014- � z o 0 m m m N J x W N O U O U y 1= Z O a � o m � CL w O 0 C U w 0.; � Y a 0 EL °w J Q Z � Z o a E o 0 3 g 0 aa< H M D 00 Q � N GENERAL NOTES 1, AAA FIRE PROTECTION SERVICES INC (AAA FPS, INC.) SCOPE OF WORK STARTS AT DISCHARGE 6' UG GATE VALVE TO BLDG RISER. UG WATER MAIN, TAPPING SLEEVE AND VALVE BY OTHERS. 2. ALL WORK PERFORMED SHALL COMPLY WITH NFPA 13, 24 AND 25 STANDARDS, LOCAL AHJ REQUIREMENTS, AND STATE FIRE MARSHAL REQUIREMENTS. 3. AAA FPS, INC. SCOPE OF WORK DOES NOT INCLUDE ANY WIRING OF DEVICES OR PAINTING OF PIPE, ETC. 4. ALL SPRINKLERS SHALL BE STANDARD COVERAGE (QUICK RESPONSE) ORDINARY TEMPERATURE (UNLESS OTHERWISE NOTED). 5. SPRINKLERS TO BE PROVIDED BELOW ALL EXPOSED DUCT, SUSPENDED EQUIPMENT AND MEZZANINES EXCEEDING 48" IN WDTH. 6. ALL PENETRATIONS IN FIRE /SMOKE WALLS TO BE PROVIDED WITH A WITH A U.L. LISTED FIRE STOP ASSEMBLY. 7. UNDERGROUND PIPING SHALL BE FLUSHED PRIOR TO SPRINKLER SYSTEM BEING TIED -IN. B. ENTIRE SYSTEM TO BE FLUSHED AND HYDRAULICALLY TESTED IN ACCORDANCE WITH NFPA -13. 9. SPRINKLER SYSTEM HAS BEEN DESIGNED NTH A MAXIMUM WORKING PRESSURE OF 175 PSI. 10. ENTIRE SPRINKLER SYSTEM TO BE INSTALLED IN A MANNER THAT THE ENTIRE SYSTEM CAN BE DRAINED. WHERE REQUIRED AUXILIARY DRAINS WILL BE PROVIDED. OCCUPANCY CLASSIFICATIONS THE FACILITY IS PROTECTED BY A WET -PIPE FIRE SPRINKLER SYSTEM, BASED ON THE FOLLOWING OCCUPANCIES AND DESIGN CRITERIA: OFFICES AND LIKE SPACES: LIGHT HAZARD OCCUPANCY, 0.10 GPM /SQFT DENSITY, 225 SOFT MAX SPRINKLER SPACING, 100 GPM COMBINED HOSE STREAM DEMAND. MECHANICAL, KITCHEN, JANITOR, AND LIKE SPACES: ORDINARY HAZARD (GROUP 1) OCCUPANCY, 0.15 GPM /SOFT DENSITY, 130 SOFT MAX SPRINKLER SPACING, 250 GPM COMBINED HOSE STREAM DEMAND. STORAGE SPACES: ORDINARY HAZARD (GROUP II) OCCUPANCY, 12'0' MAXIMUM STORAGE HEIGHT, 0,20 GPM /SQFT DENSITY, 130 SQFT MAX SPRINKLER SPACING, 250 GPM COMBINED HOSE STREAM DEMAND. e PERMIT No: N / A CONTRACT No: C09 -250 APPROVAL: CBT DRAWN BY: RTS SCALE: 1/4" = 1' -0' DATE: 11/19/2009 FLOOR PLAN FIRE PROTECTION A SPRINKLER LEGEND FINISH ITEMP I K INPT ISIN iMODEL# F p — BRASS 155 5.60 1/2" GLM15 GLOBE GL SERIES Y: \Engineering \Project CAD dwgs \Sky Dive City\_Acad \sky dive city - Plot.dwg 2/18/2010 5:03:09 PM Q) Q) l/ 1 0 C\2 4_j 0 i~ 0 U ''°' 0 O � U GENERAL NOTES 1, AAA FIRE PROTECTION SERVICES INC (AAA FPS, INC.) SCOPE OF WORK STARTS AT DISCHARGE 6' UG GATE VALVE TO BLDG RISER. UG WATER MAIN, TAPPING SLEEVE AND VALVE BY OTHERS. 2. ALL WORK PERFORMED SHALL COMPLY WITH NFPA 13, 24 AND 25 STANDARDS, LOCAL AHJ REQUIREMENTS, AND STATE FIRE MARSHAL REQUIREMENTS. 3. AAA FPS, INC. SCOPE OF WORK DOES NOT INCLUDE ANY WIRING OF DEVICES OR PAINTING OF PIPE, ETC. 4. ALL SPRINKLERS SHALL BE STANDARD COVERAGE (QUICK RESPONSE) ORDINARY TEMPERATURE (UNLESS OTHERWISE NOTED). 5. SPRINKLERS TO BE PROVIDED BELOW ALL EXPOSED DUCT, SUSPENDED EQUIPMENT AND MEZZANINES EXCEEDING 48" IN WDTH. 6. ALL PENETRATIONS IN FIRE /SMOKE WALLS TO BE PROVIDED WITH A WITH A U.L. LISTED FIRE STOP ASSEMBLY. 7. UNDERGROUND PIPING SHALL BE FLUSHED PRIOR TO SPRINKLER SYSTEM BEING TIED -IN. B. ENTIRE SYSTEM TO BE FLUSHED AND HYDRAULICALLY TESTED IN ACCORDANCE WITH NFPA -13. 9. SPRINKLER SYSTEM HAS BEEN DESIGNED NTH A MAXIMUM WORKING PRESSURE OF 175 PSI. 10. ENTIRE SPRINKLER SYSTEM TO BE INSTALLED IN A MANNER THAT THE ENTIRE SYSTEM CAN BE DRAINED. WHERE REQUIRED AUXILIARY DRAINS WILL BE PROVIDED. OCCUPANCY CLASSIFICATIONS THE FACILITY IS PROTECTED BY A WET -PIPE FIRE SPRINKLER SYSTEM, BASED ON THE FOLLOWING OCCUPANCIES AND DESIGN CRITERIA: OFFICES AND LIKE SPACES: LIGHT HAZARD OCCUPANCY, 0.10 GPM /SQFT DENSITY, 225 SOFT MAX SPRINKLER SPACING, 100 GPM COMBINED HOSE STREAM DEMAND. MECHANICAL, KITCHEN, JANITOR, AND LIKE SPACES: ORDINARY HAZARD (GROUP 1) OCCUPANCY, 0.15 GPM /SOFT DENSITY, 130 SOFT MAX SPRINKLER SPACING, 250 GPM COMBINED HOSE STREAM DEMAND. STORAGE SPACES: ORDINARY HAZARD (GROUP II) OCCUPANCY, 12'0' MAXIMUM STORAGE HEIGHT, 0,20 GPM /SQFT DENSITY, 130 SQFT MAX SPRINKLER SPACING, 250 GPM COMBINED HOSE STREAM DEMAND. e PERMIT No: N / A CONTRACT No: C09 -250 APPROVAL: CBT DRAWN BY: RTS SCALE: 1/4" = 1' -0' DATE: 11/19/2009 FLOOR PLAN FIRE PROTECTION A SPRINKLER LEGEND FINISH ITEMP I K INPT ISIN iMODEL# F p — BRASS 155 5.60 1/2" GLM15 GLOBE GL SERIES Y: \Engineering \Project CAD dwgs \Sky Dive City\_Acad \sky dive city - Plot.dwg 2/18/2010 5:03:09 PM