Loading...
HomeMy WebLinkAbout10-10181 CITY OF ZEPHYRHILLS 5335 -8th Street (813)780 -0020 10181 ELECTRICAL PERMIT : ``.. .:�t:Airri a m.. s °: .:,- . 4 , .:> Permit Number: 10181 Address: 7810 GALL BLVD Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: ELECTRICAL MISC Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Contractor: LTL CONSTRUCTION INC Book: Page: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 35- 25 -21- 0010 - 00700 -0000 Improv. Cost: 7,000.00 , a -$; ° A z ero Date Issued: 3/04/2010 \ a Na PRIMERICA GROUP ONE Total Fees: 157.50 Address: 3629 MADACA LANE Amount Paid: 157.50 TAMPA FL 33618 Date Paid: 3/04/2010 Phone: (813)933 -0629 Work Desc: INSTALL ELECTRICAL OUTLETS /LOW VOLTAGE PHONE LINES UPS STORE BUILDING FEE 97.50 ELECTRICAL FEE 35.00 FIRE PLAN REVIEW FEES 25.00 'r ROUGH ELECTRIC P .._. CONSTRUCTION POLE PRE -METER FINAL ' - 2-1 - 10 REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to any one of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspection called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same. "Warning to owner: Your failure to record a notice of commencement may result in your payin., twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be perfo e in accordance with City Codes and Ordinances. 6 k12.- air 4 1 C•NT • CTiR PERMIT OFFI fR PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER • City ofZephyrhills BUILDING PLAN REVIEW COMMENTS Contractor omeowner: A 7 Z - � s,77 �Date-Received: - / — /'v Site: 7 0/'/) G-� FJ ( ii 7v'Ck ere Permit Type: . ,�'Gd C2e " . „,ZA S Approved w /no comments:l0 Approved w /the below comments: ❑ Denied w /the below comments: ❑ I This co •• ....1St sheet shall be kept with the permit and/or plans. —A) .. -. Bill : urgess wilding Official Date Contractor and/or Homeowner (Required when comments are present) i i . j Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (813) 780 -0041 Kerry Barnett Fax (813) 780 -0044 E -mail: kbarnett @fire.zephyrhills.fl.us Plan Review #: 10 - 012 Project: Interior Improvements Number of Pages: 5 1,2010 I have received and reviewed the plans for the interior improvements located at 7810 Gall Blvtl and will allow the project to move forward. Please note that this review does not eliminate any further requirements as the project continues moving forward. By receiving Wit, contractor acknowledges to comply with the items listed below. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. 1. Penetrations in fire wall shall be completed to a listed UL design. 2. No storage is allowed with 18" of sprinlder heads. 3. Egress shall be maintained at all times. 4. Gate shall remain open as noted on plans. 5. If fire sprinlder system has to be changed because of obstructions, plans will need to be submitted to obtain a permit. 6. If fire alarm system changes, plans will have to be submitted to obtain a permit. 7. Fire extinguishers shall be within 75' of travel distance, typically one in front and one in the rear satisfies the requirement. pcctrons Required: 1. Final ,4 001■if KERRY B e TT, FIRE MARSHAL ** *Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Fire Chief Keith Williams Bus (813)780 -0041 Fax (813)780 -0044 FIRE SERVICE .USER FEES Occupancy No.: Plan No.: /6 - 4 Contractor: i- ccnskrie.47 L Business Name: U P.S S - d /zc Billing Address: ��/ E z ' Sy-- Business Address: - gi Q 6.,4 -`i jdt.J++ pe,.. �L 3 360S Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES _ INSPECTION FEES _ PERMIT FEE _ FALSE ALARM FEE Site Plan N/C _ Annual N/C iill _ Sprinlder $50 1st Alarm N/C Mufti-Family/Commercial 06 sf _ 1st Re- inspection N/C _Standpipes $50 2nd Alarm N/C um Charge $25.00 _ 2nd Re- inspection $100 _Fire Pump $50 3rd Alarrn N/C • - - - - • • - s DBL ^ 3rd Re- inspection $250 _ Hoods $50 4th Alarm $100 — 4th Re- Inspection $500 _ Fire Alarm $50 _ 5th Alarm $150 _ SPRINKLER SYSTEMS (Business closed until _ LP Gas $50 _ 6th Alarm $200 _ 0 - 25 Heads $50 violations corrected) Natural Gas $50 _ NON COMPLIANCE $150 26 plus Heads $100 _ SPRINKLER SYSTEMS Fuel Tanks - perank $50 STANDPIPE SYSTEM _ Hydro Undergrounds . $45 _ Sparklers $100 0 Per Riser $50 H rostatic Test Fire Works $50D Yd $65 per system _ FIRE PUMP _ Acceptance Test $45 per system _ Camp Fire $25 0 Per Pump $100 _ Hydrant Flow $75 _ Controlled Bum $100 FIRE ALARM SYSTEM _ Hood/Duct $50 0 - 25 Devices $50 _ FIRE ALARM SYSTEM _ Place of Assembly $50 Annual _ 26 plus Devices $100 _ System Acceptance $50 ` _ Fire Protection $25 _ SUPPRESSION SYSTEMS _ Recall Acceptance $50 _ Flammable Application 550 Annual _ Wet $5 _ OTHER Waste Tire Storage $50 Annual Dry $50 _ Fire Wall/Smoke Wall $15 per wall Generator < KW $100 _ CO2 $50 _ LP Gas $25 perank ,— Generator >30 KW 150 — Other $50 ` Natural Gas $25 per syste Bio-Hazard Waste $100 Annual KITCHEN EXHAUST _— Fumigation Tenting $50 0 Hood/Ducts $50 _ Tent 10'x10' or greater $15 per tent _ Torch Pot/Applied $50 OTHER _ Fire Pump $ 45 _ Haz. Materials $100 Annual LP Installation per tank $ 50 _ Fire Suppression $30 Fuel Tank Installation $50 _ System Acceptance (Per Tank) $50 _ Exhaust. Hood/Duct $30 0 Natural Gas Installation $50 _ Re - inspection DBL (Per System) (other than annual) 0 Spray Booth $50 0 Inspection scheduled DBL _ and cancelled Tess than 24 hours _ — _ Construction Insp. N/C _ Emergency Vehicle AG $50 FALSE ALARM PLANS TOTAL {+ INSPECTION TOTAL I I PERMIT TOTAL TOTAL I I GRAND TOTAL I a lc _ I Comments: Date: 3 -1- /t) . InsRlctor: J r ry e(,Lylv... 813 - 780-0020 City of Zephyrhills Permit Application 10 L \ Fax - 813- 780-0021 , Budding Department ,'--) Date Received --! g - I Phone Contact for Perm!tting p 3 I - l 27 p 1 Owner's Name V / Hc (A illy Cl Akira' '` Owner Phone Number r, r3 745 - j 0 Owner's Address I/0 rd 7 / c ..0 ,..,- px. 7)R, 7--4'Ye4 Owner Phone Number I Fee Simple Titleholder Name 336 Owner Phone Number -- Fee Simple Titleholder Address 1.-- ld JOB ADDRESS 2 8/ 0 ‘,4,11/ 3/1 2it/Hy/rH C j= 7, 3 I LOT # I I SUBDIVISION I PARCEL ID# I (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR I I ADD /ALT n SIGN ► t MOVE n DEMOLISH INSTALL REPAIR PROPOSED USE I J SFR I I COMM ® OTHER I I TYPE OF CONSTRUCTION n BLOCK 1 I FRAME El STEEL 1 OTHER ( I DESCRIPTION OF WORK I ft cTit Z d i T4ls — A 4..L., - JC/va ,. "c - /00 •^..r' (;,4 _ - 1 , A ,r s BUILDING SIZE SO FOOTAGE 1 iiUV HEIGHT I / / / ... ...................... ........................... ' BUILDING $ . 6 ✓/ / a Q VALUATION OF TOTAL CONSTRUCTIO / _- ELECTRICAL $ 00 AMP SERVICE * 1 1 PROGRESS n W.R.E.C. n PLUMBING $ Al i • r ` S D F MECHANICAL I$ VALUATION OF MECHANICAL INSTALLATION n GAS n ROOFING 1 1 SPECIALTY ( OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA I IYES n NO : BUILDER _ r COMPANY I A / . C r- 57�vC"rt °Uti n� SIGNATURE REGISTERED C - N J FEE CURRENT J Y/ N Address ` 1 1 License* ( 0 J ' E EL C cTRI IA --- ---- ) a COM `j . I r I `( �L!' ( SIGNATURE REG Y/ N I FEE CURRENT J Y/ N 1 Address (a� Sc� u � l�v� o f p t ) ) S v It p L - 3�{602 License* I GC 6 300 . .3 4 ii i PLUMBER COMPANY SIGNATURE REGISTERED J Y/ N J FEE CURRENT J Y/ N I Address 1 1 License # 1 MECHANICAL COMPANY I SIGNATURE REGISTERED J Y/ N 1 FEE CURRENT J Y 1 N J Address 1 1 License* I I OTHER COMPANY SIGNATURE REGISTERED J Y / N I FEE CURRENT J Y/ N I Address 1 1 License # I I RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R -O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions/large projects COMMERCIAL Attach (3) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R -O-W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. *""'PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $5000) " Agent (for the contractor) or Power of Attomey (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs Sewers Service Upgrades NC Fences (Plot/Survey /Footage) Driveways -Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division — Licensing Section at 727 -847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90 -07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water /Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law — Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S /OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection - Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. Southwest Florida Water Management District - Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers - Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services /Environmental Health Unit - Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency- Asbestos abatement. Federal Aviation Authority- Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V" unless expressly permitted. If the fill material is to be used in Flood Zone "A ", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. t understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN A r ORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT (F. . 17.03) !tt O WNER OR AGE T , s jr 1, ` CONTRACTOR .� / s r. . (or affi '� - • - - 1 r affirmed bes L 0J by r it II J 0 �OOn by l l)i I l l��l J _ I T\ personally known t. • or has/have produced Who is! personally known to or produced F l DL to -1 as identification. 1-L V)L .1 -(-130 - lo"--1-(19 identification. ' 5 Notary Public 1 a Notary Public Commission No. DO 8L18 Commission No. DO O LI p 4- SO tee r a me of Notary typed, pilled or stamped Name of Notary d � ry printed r stamped ,,, • RY � , ,, � r4;•• 1 ,ti ,µ, p( �� e ' , o � B,. BRIANNA KAY SLATER 1 ;o �� BRIANNA KAY S 'r: ;3 ; Notary Public • State of Florida 1 , • Notary Public - State of Florida ■ I DO 848337 ",te � My Comm. Expires Dec 30, 2012 1 "; 111 off? My Comm. Expires Dec 30, 2012 1 ''•.f o �d;:�' Commission 4E ` 1 ''•F ,,,, Commission # 0D 848337 - III IIIIIIIIIIIUIIIIIIIIIIIIIIUIIIIIIIIIIIIIIIIIIIIi 201 0030387 IIIIIII Rept:1291967 Rec: 10.00 0.00 IT: 0 ' 03 /04/10 C. Cook Dpty Clerk PAULA S O'NEIL, PASCO CLERK & COMPTROLLER 03 /04/10 li PG of 1 OR BK 8281 302 NOTICE OF COMMENCEMENT Permit No. Property Identification No. 3 Sr' D � • • a 1 „ O1 3 0 0 0 0 0 — p % tj o THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, 713.13 of the Florida Statutes, the following information is provided in this NOTICE OF COMMENCEMENT. l •Description of p a) Street property ) 2 e k r Co ‘44. ►,.t. n ,' 1 4 r e I P(3 2. General description of improvements: E c t t 13 t v c4 Z , P G 13 Z° r 1 N �h r h,1ts f 33��ii ( F /cur.•; l+e I I JYVt 1 1 U ✓' c 3. Owner Information a) Name and address: k \✓ k C in a ,, r , b) Name and address of fee simple titleholder (if other than owner) �` @ �a ✓ c u Tu�� c) Interest in property j c o et. fi / �� y 7 *44. Contractor Information a) Name and address: T L C tph S - nit/ ct o r 9 b) Telephone No.: 'S t I c 3 Z? ..r S rv1.-1 t a c t], I /{ - 5. Surety Information 3 ` L/ ` 3' e 1-4 " `/° 4 3 6 r Fax No. (Opt,) +rr� • , y. 2 a) Name and address: �' b) Amount of Bond: c) Telephone No.: 6. Lender Fax No. (Opt.) a) Name and address: 7. Identity of person within the State of Florida desi by Phone No. a) Name and address: owner upon whom notices or other documents may be served: b) Telephone No.: 8. In addition to himself, owner designates the followin Fax No. (Opt.) g person to receive a copy of the Lienor's Notice as provided in Section 713.13(1) (b), Florida Statutes: a) Name and address: b) Telephone No.: Fax No. S. pa ton date of Notice of Commencement (the expiration date is one year theOdat) Exirai e of recording unless a 9 Ex different date is WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR EJ j NOTICE OF A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOU Y BEFORE LENDER OR AN ATTORNE BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. FIRST STATE OF FLORIDA 1 ___L COUNTY OF PASCO ) Signature of Owner or s Authorized Officer/Director/Partner/ 1 : _ C.-1 4 i2 c, Tom/ Print Name The, foregoing instrument was acknowledged before me this in fact for .1 �,I r as g _ t?; �- : 2 day of jV l r i r c 20� by c , 4-- r �/ • - (type of authority, e.g. officer, trustee, attorney (name of party on behalf of whom instrument was executed). Personally Known OR Produced Identification Notary Signature ,.-_ Ai Type of Identification Produced f7r r 1 r —7 Name (print) l / Verification pursuant to Section 92.525, Florida Statutes. Under the facts stated in it are true to the best of my knowledge and belief. penalties of perjury, I dam] that I have read the foregoing and that FORMSMOC,rvsdZpp7 -,z,„ r `''t ("s TAT • ' ' 4 1 - 16A, COUNTY OF PASCO ' h4y� Signature of Natural Person Si_ ?n !4_ I .. - ' C � • G IS A 1 , ;; � ERIC D. RIBS • TRUE AND CORRECT COPY OF THE DOCUMENT #01 MY COMMISSION #DD 928277 ON FILE OR OF PUBLIC RECORD IN THIS OFFICE XPIROcber 10 2013 , ' � 6o nd E edTnm ES : NaatyP to utNcur MerwrNers JVITNES� MY HAND A OFFICIAL BEAL THIS `l " :L 26/ LER PAULA' Q 'N JAYOF IL LERt.(..& COMPTROL ( ` . r . BY DEPUTY CLERK 1 N 1 a ±71' -1%" 00 +I COMPONENT LIST HANDICAP ACCESSSIBLE COUNTER @ C06 A.F.F. COUNTER COMPLIES WITH ADA 11.4.2, 11.4.2.4 AND 11-4.2.6 FOR SIDE APPROACH. COUNTER COMPLIES WITH FIGURES 6(a), (b) & (c). COUNTER ALSO CONTAINS A PULL OUT SHELF IF NECESSARY, FOR ADA USE. CORNER POST EXTENDED TO STRUCTUR7 GATE POCKET DOOR FOR SLIDING GATHt17 PAI NT SPEGII ICATIOTA LAMIN E A IN�n a SPEC: SHERWIN WILLIAMS BASE CABINETS: WILSONART NATURAL TIGRIS 4669 -60 & PK)NITE COLOR: SEMI -GLOSS NOSTALGIA WHITE SW1347 EGGSHELL WHITE SW803 -S (VERTICAL GRADE) WALLS: LATEX BASE COUNTER TOPS: WILSONART GRAPHITE NEBUTA 4623 -60 (HIGH WARE TRIM: LATEX BASE FINISH) 5. Install level loop carpet per EDGE BANDING: WILSONART BLACK 1595 -60 MBE specifications. To be ordered from MBE approved vendor. CUBE WALL: WILSONART NATURAL TIGRIS 4669 -60 (VERTICAL GRADE) WOOD OR METAL STUDS DEPTH PER PLAN Q - C7 PAINT FINISH 4" MIN. PER MBE SPEC BACKING POCKET PLATE STOP AT FLOOR & TRACK ABOVE - PROVIDED BY MANUFACTURER SLIDING GAT&, 10" POCKET COVER DOOR WITH ANTIQUE WHTE MELAMINE AS PER MBE SPECS & PIANO HINGE (U.O.N.) HEIGHT OF DOOR VARIES - VERIFY ACTUAL HEIGHT ON SITE DOOR SHOULD EXTEND FROM BOTTOM OF TRACK TO FINISH FLOOR - 1/2 "GYPSUM BOARD G5 POCKET DETAIL PLAN VIEW NOTES: 1. GATE HEADER TRACK SUPPORT AND POCKET TO BE BUILT BY LOCAL LICENSED CONTRACTOR TO MEET ALL APPLICABLE BUILDING CODES AND REGULATIONS. DETAILS PROVIDED CONSTITUTE A BUILDING SUGGESTION ONLY. SITE CONDITIONS OR LOCAL BUILDING CODES MAY REQUIRE OTHERWISE. 2. THIS HEADER TRACK SUPPORT APPLIES TO SLIDING ALUMINUM ALUMATEK GATES ONLY. 5 -Gate Pocket Detail Scale: 3/8" = 1' -0" " steel bolts at each angle nrnviria f}R x 7n c�ramc SCALE: 1/4" = 1' -0" TR# i ACCESSORIES 1 TOILET PAPER HOLDER, DOUBLE W /SHELF 2 PAPER TOWEL DISPENSER 3 SANITARY NAPKIN DISPOSAL 4 HC 18 "X30" FRAMED MIRROR W /SHELF 5 SANITARY NAPKIN DISPENSER, RECESSED 6 SOAP DISPENSER, SINK MOUNTED 7/8t GRAB BARS 9 4' 0" MIRROR LENGTH OF COUNTER . PLAN KEY NOTES: O COLOR: 1. Existing door to remain. WEMT: 25 OL 1/8 GAUGE -8.87 STITCHES /IN. 2. Existing storefront to remain. 100% NYLON CONTINUOUS FILAMENT BACKING: 3. Existing electrical panel. 98 "r( 4. Desk by Owner; desk must fit in space 5. Install level loop carpet per MBE specifications. To be ordered from MBE approved vendor. 6. Change in floor material. o 7. Metal roll down security gate (if applicable) 11 > 8. Metal sliding security grill. The security grill shall remain in thy; full open LOR COPIER position during the period of occupancy by the general public. A sign shall be 0 R 1 10 posted adjacent to the security grill (letters not less than V high) with W V1 contrasting letters and background stating: "THIS DOOR TO REMAIN OPEN WHEN THE BUILDING IS OCCUPIED ". �C 9. Provide electrical surge protector at this location. g" field verify NIGHT LOBBY $tiles 10. Wall mounted bubble wrap dispenser. Ceiling Ht 11' -0' 11. Color filler panels to be inserted on back of graphic panel. D 12. Key Cabinet � N 13. Security gate per MBE specifications N1_AN_NQ_1 _ - - - - _ -_ - °O 14. Wood / metal storage cartons racks by owner (approved by MBE) �Ty_GAT9__ \ 9• - 15. Walls painted per MBE specifications. 16. Storefront door sensor to be mounted per manufacturers specifications. \ ALK 17. MBE standard menu board suspended from ceiling. \\ 18. MBE vertical menu board to be mounted to wall. ILE N 19. 2- A:10 -B:C fire extinguisher 20. New door. \ 21. VCT tile. \ 22. Mailboxes provided by MBE vendor \\ 23. Vinyl cove base. \\ 24. NOT USED. 1 25. Entry walk off tiles POS /CMS 26. Illuminated exit sign per code SYSTEM 27. Acoustical ceiling is to be installed per lease agreement unless the ceiling is existing to remain as is. b I 28. Existing slab to be saw cut for electrical trench / supply to front counters. ^�� Verify location for trench in the field. SEE FLOOR I I "� 29. Contractor to confirm that the Landlord has provided NFPA code I � PLAN 7 compliant exit lighting at the means of egress as noted. If no exit signs have NOTE 5 R ! v been provided then the contractor is to install the proper exit signage above any exit doors. 30. Contractor to provide code compliant emergency battery packs on the side ` walls and rear wall of the tenant space for activation upon a power failure or R7 emergency condition. 31. All finishes are to be Class B minimum. 32. All interior walls are to be 3 - 5/8" metal studs @ 16" o.c. with 112" drywall on both sides to the finished ceiling above. Studs at max 4' o.c. shall be ' extended to the structure above for support. 33. Contractor to field verify all existing and new construction conditions. 6' -1 %" 9" 34. All doors to be openable from the inside without the use of a key or special knowledge. No dead bolts or sliding bolts. 35. Contractor to verify that existing tenant demising wall (if applicable) complies with the construction requirements of UL #U465 for one (1) hour construction. 36. NOT USED. 37. Contractor to maintain the existing sanitary and water lines when adjusting the fixture locations for ADA compliance clearances. 1 - Floor Plan - 38. Contractor is to verify that toilet accessories exist as noted on plan. Any non - compliant accessories shall be replaced. 1 39. Contractor to realign sprinkler heads as required for new construction (if Dimensions & Notes applicable). Provide signed and sealed calculations to substantiate layout if new heads are added to existing layout. N 0 R- H 40. Contractor to verify hardware with the Owner. All hardware to be ADA Scale: 1/4" = 1' -0" compliant. 41. Per Section 410, 410.1 of the Florida Plumbing Code, 2004 ,bottled water can replace 50% of the required drinking fountains. This space is provided with bottled water as noted. See the floor plan note location. 42. To the best of our knowledge no fire alarm system was designed or required as part of the shell design and, therefore, is not required for this particular tenant. 43. The contractor shall verify the location of all fire wall penetrations in adjacent spaces. Any new fire wall penetrations shall be coordinated to ensure compliance with FBC 2004, Section 712.3.2, allowing any individual max penetration size of 16 square inches and a max of 100 square inches of penetration for every 100 square feet of wall space. No boxes are to be back to { M TG HT. I (FOR REF € back and any back to back conditions must be separated by a minimum of 24" STD H.C R E M A 21" 21" I TO CENTER LN E ti BRADEX 5263 44. All above ceiling systems wiring (commu> ications, speake,appint of sale, „ „ i etc. shall coin p1 with NEC Articles 300 and 800 for restrlctionsgn the type of 48 48 TO TOWEL DISCHARGE BRADEX 250 -15 wiring used and the method of installation. 34" 34" HEIGHT TO TCP BRADEX 4791 -15 70" 70" HEIGHT TO TAP BRADEX 782 50" 50" HEIGHT TO TT BRADEX 4017 P - 35" 4" SPOUT IN NO LAVATORY BRADEX 6322 -68 36" 36" (rear) x ta" (side) BRADEX 059 i 1 - TOP OF BACkSPLASH Fasten to structure or metal deck as required. Fill all gaps with fiber insulation. Line of structure. 3 -5/8" metal runner Line of metal stud, stop stud 112" below metal runner. Extend every third stud to structure and at all corners to assure proper stability of partition. Scheduled ceiling. 3 -5/8" metal runner fasten min. 24" O.C. Scheduled base. Scheduled floor finish. 4 -Gate Head Deta UPS Store 11�I1 ��� �; G �1 } �COI �� I , OR ' SAC , �Clfly �ULl C1�� Cont. 2 x 6 Cont. 1 x 4 shim - sliding gate track sliding gate (approx 12 lbs per lineal foot) r _ r_ I mo. r __ r _ _ 7 - Gate Support - Pocket NTS CAF1Pr_ - OASE MANUFACTURER: SHAW COMMERCIAL STYLE: SOLUTION YARN/LEVEL LOOP COLOR: MBE CHARCOL GRAY RANDOM PATTERN WEMT: 25 OL 1/8 GAUGE -8.87 STITCHES /IN. TYPE: 100% NYLON CONTINUOUS FILAMENT BACKING: UNITARY ACTION BACK APPUCATK)N: GLUE DOWN o •� > _O W V1 �C Cont. 2 x 6 Cont. 1 x 4 shim - sliding gate track sliding gate (approx 12 lbs per lineal foot) r _ r_ I mo. r __ r _ _ 7 - Gate Support - Pocket NTS CAF1Pr_ - OASE MANUFACTURER: SHAW COMMERCIAL STYLE: SOLUTION YARN/LEVEL LOOP COLOR: MBE CHARCOL GRAY RANDOM PATTERN WEMT: 25 OL 1/8 GAUGE -8.87 STITCHES /IN. TYPE: 100% NYLON CONTINUOUS FILAMENT BACKING: UNITARY ACTION BACK APPUCATK)N: GLUE DOWN Section View 5/8" gypsum wallboard with two coats of compound at joints and screw heads. Paper tape 2" wide embedded in first coat each side. 3 -518" metal studs at 16 "o.c. maximum Plan View Wall Type - W2 Non -Rated Metal Stud Partition Scale: 1- 1/2 " =1' -0" 6 - Standard Partition Detail NTS Provide minimum 1" washers and nut to draw up threaded rod " steel ALL THREAD at 24" o.c. at each point of attachment to the joist Cont. 2 x 6 suspended ceiling tiles Cont. 1 x 4 shim sliding gate track sliding gate (approx 12 lbs per lineal foot) Parking Lot Ke y Plan NTS Project Description This project consists of the remodel of the existing tenant space. Building Classification Occupancy: 1. The tenant is a Group B, Business Occupancy. Codes in Effect: Florida Building Code - Building, 2007 National Fire Protection Agency (NFPA) Life Safety Code - 2003 Edition Florida Building Code - Plumbing, 2007 Edition Florida Building Code - Mechanical, 2007 Edition Florida Building Code - Fuel Gas, 2007 Edition National Electric Code, 2005 Edition Florida Building Code /Americans with Disabilities, 2007 Edition Type of Construction: Single Storey Building: Type IIB Allowable Building Area per Table 500: Type IIB 1. Business, 75'/ 5 storey Height (per FBC 504.2); UL s.£ (per FBC 507.1) Occupant Load Factor per FBC Table 1004.1.2: 1. Group B = 100 gross sf per occupant Total Square Feet = 1435 Total Occupant Load = 15 Minimum number of required exits = 1 (per FBC 1018.2) (2) Exits provided Maximum Travel Distance per FBC Table 1015.1: 1. Group B Occupancy, sprinklered Travel distance shall NOT exceed 300 feet Dead -end corridor shall NOT exceed 50 feet (per FBC 10 16.3, exception 2) Minimum Corridor Width and Rating per NFPA 101 Chapter 5: 44" Clear, 44" for stairs Egress Width Egress capacity, per Table 1005. 1, FBC 2007, is 0.2" per occupant. The egress doors for the tenant space are 36" wide. The total capacity of the egress door is 180, exceeding the occupant load of 10. RICK Z. SMITH BL ASSOCIAT ARcHITUH Rick Zane Smith Florida Reg No. 10,527 P.O. Box 262197 Tampa, Florida 33685 -2197 Tel (813) 901 -9663 Fax (813) 855 -1135 EMAIL rzs @rzsarchitects.com AA 000 2246 Consultant 2 Q\ j ect Team Owner Representative: LTL Construction, Inc. 2601 E. 4th Street Tampa, Florida 33605 (813) 242 -4848 William Pugh, Jr. Architect: Rick Z. Smith & Associates Architects, Inc. 16017 N. Florida Avenue Suite 102 Lutz, Florida 33549 P.O. Box 262197 Tampa, Florida 33685 -2197 (813) 901 -9663 Lie# AA 000 2246 Rick Z. Smith, NCARB Project Architect 1 7610 1 I ka L9ris���`N� �G �UI3:\ tl'1'TEI) PLAN II `.V1 BEEN V CEL t1Y 'ZEPHYRHILL. 1 ltSH L Date: --- I R e viewer: _ c�tr� b advised (his review of plans submitted iS a ew to assist the contractor in compl i ance fife Safpt C.O S. This review is not intended I al approval of the submitted plans. It is the ton(ru2 ofa responsibility to. ensure that the plans are in comp: mpliance with all appticable NFPA cosies and local t ces. In the event that further examination or site in; n reveals areas of non. it shall be the cot r's sole responsibility, at their sole expense to bting areas in compliance. The City assumes no respon fix the contactors failure to be in compliance with kable NFPA Codes ancl focal oniinances. Drawing Date: 2 -12 -10 Project Number 1003 Drawn By: MC Checked By: RZS Sheet Title Floor Plan Sheet Number A2.10 n 3 - Enlarged Toilet Plan L�J G4 HEADER TRACK SUPPORT DETAIL SIDE VIEW 1 or 2 hour fire or smoke wall Acoustical sealant back and sides of box as necessary for sound rating Acoustical sealant around box penetration Maximum 16 square inches maximum opening 100 square inches per 100 square feet Telephone or electrical boxes Adjacent electrical boxes (Per FBC 2004, Section 712.3.2) Laminate back piece to wallboard i Shallow five side box detail Required where box exceeds 16 square inches or aggregate of boxes exceeds 100 square inches per 100 square feet of wall area Electrical junction boxes When a metallic junction box for electrical receptacles or switches is within a rated wall of gypsum drywall construction and an opening is provided for the box in the surface of that wall, the area of the opening may not exceed 16 square inches, unless the junction box is enclosed by a "5 -sided box" (See approved details), The aggregate area of all such junction boxes in a rated wall not enclosed by "5 -sided boxes" described above shall not exceed 100 square inches in 100 square feet of wall area as measured from floor to structural deck or rated membrane. Junction boxes with openings on opposite faces of rated walls shall have a horizontal separation of 24 inches as a minimum, regardless of box size, unless enclosed by "5- sided boxes ". Locations of studs do not have any bearing on the above requirements, nor does the use of mineral wool fire safing alter these requirements. 9 Junction Box Stud Wall Detail N.T.S. Section View Plan View Line of structure. HW -D -0016 head condition per UL, page 1238, Volume 2A, UL2004 Sealant equal to RECTORSEAL, "Metacaulk 1000" 4.0 pcf density mineral wool Fasten to structure or metal deck as required. 3%" metal runner Line of metal stud, stop stud 1/2" below metal runner. 3%" metal stud at 16" o.c. maximum. 3" thick fiberglass batt sound attenuation blanket. Fasten stud to runner top and bottom (both sides). %" Type XP gypsum wallboard attach with 1" type(s) self tapping screws, 8" o.c. at edges 12" o.c. in field area. 2 coats of compound at joints and screw heads. Paper tape 2" wide embedded in first coat. Extend to deck where no ceiling is scheduled 3%" metal stud at 16" o.c. maximum. 3" thick batt sound attenuation blanket. Note: Partition type drawings indicate general relationship among materials and construction of partitions. Contractor shall provide complete tire rated partitions in accordance with the referred UL design numbers. Wall Type - W1 One Hour Rated Metal Stud Partition UL #U465 Scale: 1- 1/2 " =1' -0" (2) layers of J" firecode GWB for _ two hour application. - (1) layer of J" firecode GWB for one hour Typical Section application -- GWB patch butter backside UL approved caulk for rating ® S_ S surface, Do not remove joint required (MINNESOTA compound displaced at edges. MINING & MFG CO. CP25WB) –�� Type "G" screws min. 2 per \ section. Leave exposed. rn Max 4 copper conductor 8AWG pP '1 � ' Annular op ening in partition 6 min. < 3 6 min. p 9 p (or smaller) aluminum or steel around pipe or conduit 3" diameter ®S ®5 Armored Cable or Metal Clad or less. Cable bearing UL classification mark for rating Armor Cable penetrations (UL # W -L -3051) Plastic up to 2" pipe or conduit Typical seal Blow -out patch Holes up to 3" diameter A. Only 1 layer on each side of Notes: wall required for 1 or 2 hour 1. Butter entire back side of walls. patch with joint compound. B. Blow -out patch is not 2. Leave all screws exposed. acceptable on walls rated at 3 or 4 hours. 2 Blow Out Patch - Large Holes N.T.S. 0 V1 'loset 0 • B i ` N W) � rn � r b O Unsleeved penetrations For pipes and conduit not subject to movement or condensation Proprietary systems are acceptable Min. 20 GA. galvanized sleeve. Secure in wall Typical seal Insulation where applicable Safing for piping not subject to condensation or foamglass in sleeve or fiberglass with proprietary system for piping subject to condensation For pipes and conduit subject to vibration, expansion, contraction, and/or condensation Wire penetrations Unsleeved wire up to a 2" bundle Secure Acoustic caulk 1/2" max. (Safe if over 1/2 ") Typical seal Conduit for bundled wires over 2" (Sleeves shall be secured in the wall to prevent movement) Fire or Smoke wall penetrations Plaster, drywall, concrete, or masonry Typical seal as follows: Less than 112" = Acoustic caulk or drywall joint compound (No tape) More than 1/2" = Blow -out patch or proprietary system 5 Wall Penetrations N.T.S. Small openings may be patched using joint compound, caulk, or blow -out (patches. Large openings require a blow -out patch or wall repair. Smoke resistant walls � /2 - I 1 /2" max. Up to 1/2" openings may be filled full depth of drywall with acoustical sealant. Strike off at face of drywall, Do NOT spread beyond opening. Alternatively, a proprietary system may be used, Up to 1/4" openings may be filled with joint compound. Up to 1/8" openings do not require any treatment. Larger than 1/2" openings require a blow -out patch (See detail 2). Some local jurisdictions do not allow the blow -out patch. 30 min., 1 hr. & 2 hr rated walls (Fire, Fire & Smoke) 3 and 4 hour walls require the use of a proprietary system 1 Blow Out Patch - Small Holes N.T.S. CMU or concrete Proprietary system or UL tested nonshrink grout - Fill opening completely As required for closure Provide cellclos;ure of non- combustible matterial in CMU walls Concrete masonry units or solid concrete walls 3 and 4 hour walls require the use of a proprietary system Gypsum plaster and metal lath on metal studs As required for closure Plaster and metal lath Gypsum plaster, metal lath and metal stud partitions 6 Wall Penetrations N.T.S. II II II � ---- 1 - 1 - - - - M :I� � l � 1 XMN Metal studs behind gypsum board J- — I Metal runners J — — — 1 1 1 m in 1 1 Typical Sec�iolt E Pack with fire -safing at manufactured density with no voids T -- — I - 1 -- - 1 - 1 — T � or gaps IJ ___1.L � E j 48 '1 misx. I 1 Multiple conduit/pipe penetrations Section One or two layers of drywall Alternate 1: Blow -out one side of wall tape & joint compound drywall or sealant Metal runners Alternate 2: 1 face to be sealed with drywall, sealant, or tape and joint compound Note: Over V gap requires a blow- out patch Pack with fire -safing at manufactured density with no voids or gaps Alternate 1 or 2 may be used on either side of wall. One side of penetration may remain open. 4 Multiple Wall Penetrations N.T.S. II II II II ll II Cut -out max. 6 "x6" ll II 1 Stud Partial Elevation F_ — a 1 Main wall surface I • Patch L I I I I Screw I 1 Runner track section I I 1 Partial Elevation L — J Runner track section Tape and finish Section 3 Flush Patch - Small N.T.S. Typical Section �--- Studs Runner channels, typical S I--- — — — — — --1 1 GWB patch (Butter backside 1 I surface) Min. 2 "S" screws per section, min. 3" from opening and edge `•,, I I of patch > 3" 1 1 Annular opening in partition _ around pipe or conduit greater • than 3" diameter IS1- •-------- -- 1 Cut gypsum board tight to pipe 3,1 1 Do not mud and tape edges mini Holes over 3" diameter UL Details Scale: NTS M M aN r, k General Notes For Prioritv Walls 1. Encase all vertical and horizontal ducts, pipes, conduits, panels, to match adjacent surfaces, Extend the furred spaces length of the wall between intersecting walls unless otherwise indicated. The contractor shall notify the Architect should conflicts arise between furring and casework, equipment or any other items. Provide access panels painted to match adjacent surfaces where access is required for valves, dampers or other devices requiring adjustment. Provide labeled access door where enclosure constitutes part of a fire rated assembly. 2. The maximum allowable area of individual U.L, listed electrical back boxes permitted in frre/smoke walls is 16 square inches. With a maximum aggregate of 100 square inches per 100 square feet of wall area. Back boxes on opposite faces of such walls shall be offset a minimum horizontal distance of 24 inches. Penetrations exceeding the allowable areas the devices shall be set in a furred space in front of the fire or fire /smoke wall as described in notes above or provided with a five -sided enclosure as described below. 3. Items recessed in corridor, smoke or fire walls such as recessed toilet accessories, fire extinguisher and/or hose cabinets, fire alarm signal boxes, electrical and signal cabinets, or other back boxes which exceed 16 square inches shall be installed in a five -sided enclosure as indicated on the drawings. Where depth of box exceeds wall thickness, provide framing as required to accommodate depth as described above. 4. Where ducts, pipes, conduit, bar joists, beams or any other materials penetrate a fire rated wall or partition, openings shall be tightly sealed. Annular openings in CMU walls shall be filled with grout. Do not cover penetrations of CMU walls with drywall. Penetrations in metal stud partitions shall be constructed with 20 ga. Galvanized runner channel sill and header secured to metal studs, with the space around the perimeter of the penetrating object packed tightly with compressed mineral fiber insulation. Insulated pipes shall be sleeved with foam glass insulation. Annular opening between sleeve and pipe shall be sealed with approved fire and smoke retardant sealer. Sleeves shall extend a maximum of 2" beyond faces of wall. Refer to partition details and mechanical drawings. 5. Provide proper clearances at fire dampers between the sleeve and stud framing members. Fire damper sleeves shall be installed and secured in accordance with SMACNA standards. Fire dampers shall be installed in the plane of the rated assembly. 6. Low voltage wiring which penetrates a smoke or fire /smoke wall Shall be sleeved with conduit extending not more than 2 inches either side of the wall and securely anchored to prevent slipping through the wall or damaging the drywall. Remaining openings in the conduit sleeve shall be filled with tightly compressed mineral fiber safeing insulation and sealed with acoustical sealant. It is the responsibility of the general contractor to assure coordination of installation of such systems between vendors and subcontractors. The contractor shall assure that penetrations for utilities are made with the utmost care and minimum of damage to the integrity of all partitions and walls, Sleeves and conduit shall be installed prior to running cables. 7. Furnish access panels in walls and non - accessible ceilings where service or adjustment to mechanical, plumbing or electrical equipment is required, and at intervals not to exceed 30 feet in non - accessible ceilings or fire membranes adjacent to fire and fire /smoke walls. Where access panels occur in rated assemblies they shall bear a label rating equal to that of the assembly. Access panels in gypsum wallboard membranes above non - accessible ceilings shall be aligned to permit access and shall be sized to permit positioning of a step ladder through the access panel in the ceiling. Rated access panels in ceilings and membranes shall be supported from the structure, not the ceiling framing. 8. Coordinate installation of plumbing, vent stacks and conduit to permit installation of recessed toilet accessories, fire extinguisher cabinets and other recessed equipment. Where such items are recessed in corridor, smoke or fire /smoke walls they shall be installed in a five -side enclosure as described above. 9. All wood blocking within the building envelope shall be pressure treated. Isolate salt treated wood from metal framing with 15# felt and use corrosion resistant fasteners to minimize galvanic corrosion. 10. Provide acoustical sealant to prevent passage of smoke at penetrations of either smoke - resistant or fire /smoke partitions. Where fire- safing is used, the acoustical sealant shall be required only on one side of wall. Fire Protection Criteria 1. One hour rated corridor partitions shall extend to underside of floor or roof deck. 2. Smoke resistive partitions shall extend to underside of floor or roof deck or underside of gypsum wallboard membrane frreskin or to 4" above ceiling - Refer to Wall Rating Legends, 3. Smoke barrier partitions shall be constructed uninterrupted, tight from back of exterior wall and from floor slab to underside of floor or roof deck. 4. Firestopping shall be provided at the plane of the gypsum wallboard membrane or rated ceilings all penetrating partitions, exterior stud walls and furred spaces. 5. All backboxes, panels, valve boxes, toilet accessories and other recessed items in excess of sixteen square inches, which are recessed in fire rated walls shall be protected with a five sided enclosure equal to the rating of the wall. 6. The contractor shall construct all fire rated assemblies in the following order of priority: Four Hour Fire walls Three Hour Fire walls Two Hour Fire walls One Hour Fire walls Gypsum wallboard horizontal fire membrane One hour rated partitions Smoke resistive walls Non -rated interior partitions 7. The Contractor shall provide signage above the ceiling spaced at 10' O.C. indicating the rated partition type and to "PROTECT ALL OPENINGS ". Signage letters shall be 3" high in a dark red color and be placed on both sides of priority walls along their entire length. General Notes 1. All corridor walls are 1 hour rated unless noted otherwise. Refer to Al series for details. 2. See the index sheet for additional notes which also apply to this Life Safety plan. 42" soap mirror dispenser 0 0 bars (_Fl_ toilet tissue dis enser V1 'loset 0 B i ` N Water cooler I I� B 8 0 0o d' Fixtures and Accessories Mounting Heights Scale: NTS max. surface mounted paper towel t_ RICK Z. SMITH & ASSOCIATES AR�HITUT41n�. Rick Zane Smith Florida Reg No. 10,527 P.O. Box 262197 Tampa, Florida 33685 -2197 Tel (813) 901 -9663 Fax (813) 855 -1135 EMAIL rngusarchitects.com AA 000 2246 Consultant C r\ Drawing Date: 2 -12 -10 Project Number 1003 Drawn By: MC Checked By: RZS Sheet Title UL Penetrations Fire Rated Partitions Sheet Number A2.11 Sleeved penetrations V1 W) rn M b O > H 00 N Drawing Date: 2 -12 -10 Project Number 1003 Drawn By: MC Checked By: RZS Sheet Title UL Penetrations Fire Rated Partitions Sheet Number A2.11 Sleeved penetrations OUTLET 86" AFF 5IUNAUL ANLA Ceiling Ht. 11' -0" 5' - 0" T RETAIL UNIT E LECTRICAL AL. laid r Et. STANDARD 200 AMP ELECTRICAL PANEL MINIMUM. E2. LOCATION OF ELECTRICAL OUTLETS ARE APPROXIMATE. E3. USE EXISTING OUTLETS IF CLOSE TO LOCATIONS SHOWN E4. ELECTRICAL OUTLETS ARE AT 14' ABOVE FINISHED FLOOR UNLESS NOTED OR REQUIRED OTHERWISE. E5. USE DEDICATED OUTLET FOR COPIER, AND POS /CMS STATIONS. E6, REMAINING OUTLETS SHOULD BE ON AT LEAST TWO CIRCUITS. DUPLEX OUTLET: 40 DEDICATED DUPLEX OUTLET: 40 4 -PLEX OUTLET: 40 DEDICATED 4 -PLEX OUTLET. 40 E7. ELECTRICAL. AT BACK COUNTERS TO BE BELOW COUNTER TOPS WITHIN WALL E8. ELECTRICAL AT MAIN COUNTER TO RUN THROUGH MOUSE HOLES SEE NOTE E9 WITHIN THE BASE AREA. ACCESS TO OUTLET'S WITH 2' D. HOLES IN E NOTE E10 COUNTER TOP SURFACES, USE PLASTIC GROMMET COVERS TO HIDE PLUG RUNS. E9. ELECTRICAL OUTLET OR JUNCTION BOX FOR RETAIL DISPLAY AT 92' AFF (NON 24 HR. CIRCUIT). E10. OUTLET AT CEILING FOR WINDOW SIGNAGE. EXISTING STOREFRONT LAYOUT TO BE VERIFIED ON SITE FOR OUTLET PLACEMENT. E11. JUNCTION BOX FOR UNDER COUNTER CABINET LIGHTING. E12. ELECTRICAL TRENCH TO BE SAW CUT IN CONCRETE SLAB BY OWNER /CONTRACTOR FOR POWER TO FRONT COUNTERS. FIELD VERIFY LOCATION AND APPROVED BY LANDLORD AND /OR LOCAL MUNICIPALITY. E13. DEDICATED JUNCTION BOX FOR THE ATTACHMENT OF A WHIP TO THE ELECTRICAL BOX WHICH NEEDS TO BE INSTALLLED IN THE COPY TRIANGLE E14. OPTIONAL CEILING MOUNTED DUPLEX OUTLET FOR THE FLO -VAC TYPE EE NOTE E4 ALTA PACK. E15. ELECTRICAL OUTPUT AND PLUG CONFIGURATIONS DRAWN AT COPIERS MAY NOT REFLECT MANUFACTURERS REQUIREMENTS. PLEASE CONTACT THE MANUFACTURERS FOR THE TYPE OF ELECTRICAL RECEPTACLES AND SPECIFIC REQUIREMENTS FOR THE INDIVIDUAL COPIER MODELS BEING USED IN YOUR CENTER. E16. EXTERIOR SIGN JUNCTION BOX LOCATED AT STOREFRONT TO BE SUPPLIED BY DEDICATED CIRCUT FROM BREAKER PANEL WITHIN THE STORE. THE EXTERIOR SIGN INSTALLER WILL ONLY WIRE 3' -0" INTO STOREFRONT FOR CONNECTION TO SERVICE. E17. REQUIRED EXTERIOR SIGN TIMER SHOULD BE SET TO TURN ON AT DUSK AND OFF AT 11:00 PM UNLESS OTHERWISE MANDATED BY LANDLORD. E18. PHOTOCELL TIMER OPTIONAL FOR EXTERIOR SIGN AND REQUIRES FRANCHISEE AUTHORIZATION. E19. TRACK LIGHTING TO UTILIZE HARD WIRE APPUCAT10N TO BE ON A NON 24HR. LIGHTING CIRCUIT. E20, OUTLET 0 86' AFF FOR THE WIFI WAYPORT /ACCESS POINT. E21.ALL TRACK LIGHTING HEADS SHOULD BE DIRECTED TOWARDS THE POP MATERIAL HUNG ON THE CUBEWALL ABOVE THE FIXTURES. — SIEE NOTE E i \\ G4 2b L4 V4 \\ T ' 9 SEEN EE \\ SEE CITE E12 \ POS /CMS 0 \\ SYSTEM I \\ \ r it �r ♦ -- • L4 FLOOR PLAN NOTES 1. OVERHEAD OR SLIDING SECURITY GATE TO BE ORDERED BY FRANCHISE OWNER /AREA FRANCHISEE FROM THE MBE APPROVED VENDOR.. USE FORMS PROVIDED BY YOUR DESIGNER IN YOUR CONSTRUCTION) DOCUMENTS PACKET 2. SLIDING GATE IN LOBBY AREA WILL LOCK DOWN AT FLOOR AND CEILING. 3. MODULAR WALL TO BE SUPPORTED ON SITE BY OWNER/CONTRACTOR. 4. SUN SOLUTIONS BLOCK OUT FILM PER MBE SPECIFICATION$. 5. WINDOW SIGNS TO BE HUNG AT 6' -0' AFF TO BOTTOM OF SIGN. 6. SAND DOWN EDGE BANDING ON THE OUTSIDE EDGE OF THE CABINET LOCATED AT THE OF FRONT COUNTER RUN. 7. SUPPORT COUNTER TOP WITH METAL 'L' BRACKETS. COPIER REQUIRFEMEN 3 ELECTRICAL OUTPUT AND PLUG CONFIGURATIONS DRAWN AT COPIERS MAY NOT REFLECT MANUFACTURERS REQNREIMENTS. PLEASE CONTACT THE MANUFACTURERS FOR THE tYPE OF ELECTRICAL RECEPTACLES AND SPECIFIC REQUIREMENTS FOR THE INDIVIDUAL COPIER MODELS BEING USED IN AR CENTER. 9'-23/4" 6' - 0 " ELECTRICIAN TO PULL 6 PAIR CABLE AT TIME OF ELECTRICAL ROUGH IN, PHONE BOXES TO BE INCLUDED. JACK WIRING AND INSTALLATION TO BE PERFORMED BY QUALIFIED TECHNICIAN. DRAWING BASED ON USING PANASONIC MODELS KX -T3130 8A. KX -3203 OR EQUAL. N 0- R-T H 1 - Electrical Po wer /Data Plan Scale: 1/4" = 1' -0" a L1 RJ14C JACK - VOICE TELEPHONE LINE (PRIMARY) a L2 RJ14C JACK - VOCE TELEPHONE LINE (ROLL -OVER) a Li/L2 RJ14C JACK - VOICE TELEPHONE LINE (PRIMARY & ROLL-OVER) a L3 RJ11C JACK - FAX LINE /POSTAGE METER a L4 RJ11C JACK - CPU BACK -UP LINE (OPTIONAL) a LS RA IC JACK - CUSTOMER (RESTRICTED ACCESS) VOICE LINE (OPTIONAL) SEE FLOOR--, NIGHT LOBBY Ceiling Ht. 11' —O'� 1 NIGHT LOBBY Ceiling Ht. 11' -0"r SEE NOTE E9 iEE NOTE E10 "sE NOTE E I \ \ \\ U1 CAL \\ T� SEE N E E \ \ SEE FLOOR < \ SOS /CMS CITE E E12 \ \ \\ PLAN NOTE 4 \ SYSTEM 6 7 T2 \\ EE NOTE E4 E AREA \\ T7 EE NOTE E2 \1 U1 SEE FLOOR PLAN NOTE 4 QUAUFIED TECHNICIAN TO PULL CATAGORY 5, 4 PAIR CABLE TO TSB -40 AND EIA/TIA -5688 STANDARDS AT TIME OF ELECTRICAL ROUGH IN, PHONE BOXES TO BE INCLUDED. V1a NETSCREEN ® - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM STARTING CONNECTION Vib RJ45 JACK - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM ENDING CONNECTION V2a NETSCREEN @ - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM STARTING CONNECTION V2b RJ45 JACK - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM ENDING CONNECTION Via NETSCREEN ® - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM STARTING CONNECTION V3b RJ45 JACK - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM ENDING CONNECTION V40 NETSCREEN IS - FUTURE EXPANSION STARTING CONNECTION ' V4b RJ45 JACK - FUTURE EXPANSION ENDING CONNECTION V50 NETSCREEN 14 - COLOR COPIER RIP DEVICE STARTING CONNECTION V5b RJ45 JACK - COLOR COPIER RIP DEVICE ENDING CONNECTION t V6a NETSCREEN ® - DOTAL COPIER STARTING CONNECTION V6b RJ45 JACK - DIGITAL COPIER ENDING CONNECTION V7a NETSCREEN 14 DEDICATED COMPUTER RENTAL LINES STAR71NG CONNECTKN V7b RJ45 JACK - DEDICATED COMPUTER RENTAL ONES ENDING CONNECTION V80 NETSCREEN @ - BACK OFFICE COMPUTER STARTING CONNECTION V8b RJ45 JACK - BACK OFFICE COMPUTER ENDING CONNECTION V9a NETSCREEN 14 - OPTIONAL FAX NETWORK STARTING CONNECTION V9b RJ45 JACK - OPTIONAL FAX NETWORK ENDING CONNECTION V1 Da NETSCREEN tn4 - OPTIONAL NETWORK STARTING CONNECTION V10b RJ45 JACK - OPTIONAL NETWORK ENDING CONNECTION RICK Z. SMITH cYC ASSO CIATES a Rick Zane Smith Florida Reg No. 10,527 P.O. Box 262197 Tampa, Florida 33685 -2197 Tel (813) 901 -9663 Fax (813) 855 -1135 EMAIL rzs @rzsarchitects.com AA 000 2246 Consultant C I - - - --� T2 SEE NOTE Et 4 CAR alta 4'X8' CAR ETEBa I PAC G - - - � T RETAIL UNIT E LECTRICAL AL. laid r Et. STANDARD 200 AMP ELECTRICAL PANEL MINIMUM. E2. LOCATION OF ELECTRICAL OUTLETS ARE APPROXIMATE. E3. USE EXISTING OUTLETS IF CLOSE TO LOCATIONS SHOWN E4. ELECTRICAL OUTLETS ARE AT 14' ABOVE FINISHED FLOOR UNLESS NOTED OR REQUIRED OTHERWISE. E5. USE DEDICATED OUTLET FOR COPIER, AND POS /CMS STATIONS. E6, REMAINING OUTLETS SHOULD BE ON AT LEAST TWO CIRCUITS. DUPLEX OUTLET: 40 DEDICATED DUPLEX OUTLET: 40 4 -PLEX OUTLET: 40 DEDICATED 4 -PLEX OUTLET. 40 E7. ELECTRICAL. AT BACK COUNTERS TO BE BELOW COUNTER TOPS WITHIN WALL E8. ELECTRICAL AT MAIN COUNTER TO RUN THROUGH MOUSE HOLES SEE NOTE E9 WITHIN THE BASE AREA. ACCESS TO OUTLET'S WITH 2' D. HOLES IN E NOTE E10 COUNTER TOP SURFACES, USE PLASTIC GROMMET COVERS TO HIDE PLUG RUNS. E9. ELECTRICAL OUTLET OR JUNCTION BOX FOR RETAIL DISPLAY AT 92' AFF (NON 24 HR. CIRCUIT). E10. OUTLET AT CEILING FOR WINDOW SIGNAGE. EXISTING STOREFRONT LAYOUT TO BE VERIFIED ON SITE FOR OUTLET PLACEMENT. E11. JUNCTION BOX FOR UNDER COUNTER CABINET LIGHTING. E12. ELECTRICAL TRENCH TO BE SAW CUT IN CONCRETE SLAB BY OWNER /CONTRACTOR FOR POWER TO FRONT COUNTERS. FIELD VERIFY LOCATION AND APPROVED BY LANDLORD AND /OR LOCAL MUNICIPALITY. E13. DEDICATED JUNCTION BOX FOR THE ATTACHMENT OF A WHIP TO THE ELECTRICAL BOX WHICH NEEDS TO BE INSTALLLED IN THE COPY TRIANGLE E14. OPTIONAL CEILING MOUNTED DUPLEX OUTLET FOR THE FLO -VAC TYPE EE NOTE E4 ALTA PACK. E15. ELECTRICAL OUTPUT AND PLUG CONFIGURATIONS DRAWN AT COPIERS MAY NOT REFLECT MANUFACTURERS REQUIREMENTS. PLEASE CONTACT THE MANUFACTURERS FOR THE TYPE OF ELECTRICAL RECEPTACLES AND SPECIFIC REQUIREMENTS FOR THE INDIVIDUAL COPIER MODELS BEING USED IN YOUR CENTER. E16. EXTERIOR SIGN JUNCTION BOX LOCATED AT STOREFRONT TO BE SUPPLIED BY DEDICATED CIRCUT FROM BREAKER PANEL WITHIN THE STORE. THE EXTERIOR SIGN INSTALLER WILL ONLY WIRE 3' -0" INTO STOREFRONT FOR CONNECTION TO SERVICE. E17. REQUIRED EXTERIOR SIGN TIMER SHOULD BE SET TO TURN ON AT DUSK AND OFF AT 11:00 PM UNLESS OTHERWISE MANDATED BY LANDLORD. E18. PHOTOCELL TIMER OPTIONAL FOR EXTERIOR SIGN AND REQUIRES FRANCHISEE AUTHORIZATION. E19. TRACK LIGHTING TO UTILIZE HARD WIRE APPUCAT10N TO BE ON A NON 24HR. LIGHTING CIRCUIT. E20, OUTLET 0 86' AFF FOR THE WIFI WAYPORT /ACCESS POINT. E21.ALL TRACK LIGHTING HEADS SHOULD BE DIRECTED TOWARDS THE POP MATERIAL HUNG ON THE CUBEWALL ABOVE THE FIXTURES. — SIEE NOTE E i \\ G4 2b L4 V4 \\ T ' 9 SEEN EE \\ SEE CITE E12 \ POS /CMS 0 \\ SYSTEM I \\ \ r it �r ♦ -- • L4 FLOOR PLAN NOTES 1. OVERHEAD OR SLIDING SECURITY GATE TO BE ORDERED BY FRANCHISE OWNER /AREA FRANCHISEE FROM THE MBE APPROVED VENDOR.. USE FORMS PROVIDED BY YOUR DESIGNER IN YOUR CONSTRUCTION) DOCUMENTS PACKET 2. SLIDING GATE IN LOBBY AREA WILL LOCK DOWN AT FLOOR AND CEILING. 3. MODULAR WALL TO BE SUPPORTED ON SITE BY OWNER/CONTRACTOR. 4. SUN SOLUTIONS BLOCK OUT FILM PER MBE SPECIFICATION$. 5. WINDOW SIGNS TO BE HUNG AT 6' -0' AFF TO BOTTOM OF SIGN. 6. SAND DOWN EDGE BANDING ON THE OUTSIDE EDGE OF THE CABINET LOCATED AT THE OF FRONT COUNTER RUN. 7. SUPPORT COUNTER TOP WITH METAL 'L' BRACKETS. COPIER REQUIRFEMEN 3 ELECTRICAL OUTPUT AND PLUG CONFIGURATIONS DRAWN AT COPIERS MAY NOT REFLECT MANUFACTURERS REQNREIMENTS. PLEASE CONTACT THE MANUFACTURERS FOR THE tYPE OF ELECTRICAL RECEPTACLES AND SPECIFIC REQUIREMENTS FOR THE INDIVIDUAL COPIER MODELS BEING USED IN AR CENTER. 9'-23/4" 6' - 0 " ELECTRICIAN TO PULL 6 PAIR CABLE AT TIME OF ELECTRICAL ROUGH IN, PHONE BOXES TO BE INCLUDED. JACK WIRING AND INSTALLATION TO BE PERFORMED BY QUALIFIED TECHNICIAN. DRAWING BASED ON USING PANASONIC MODELS KX -T3130 8A. KX -3203 OR EQUAL. N 0- R-T H 1 - Electrical Po wer /Data Plan Scale: 1/4" = 1' -0" a L1 RJ14C JACK - VOICE TELEPHONE LINE (PRIMARY) a L2 RJ14C JACK - VOCE TELEPHONE LINE (ROLL -OVER) a Li/L2 RJ14C JACK - VOICE TELEPHONE LINE (PRIMARY & ROLL-OVER) a L3 RJ11C JACK - FAX LINE /POSTAGE METER a L4 RJ11C JACK - CPU BACK -UP LINE (OPTIONAL) a LS RA IC JACK - CUSTOMER (RESTRICTED ACCESS) VOICE LINE (OPTIONAL) SEE FLOOR--, NIGHT LOBBY Ceiling Ht. 11' —O'� 1 NIGHT LOBBY Ceiling Ht. 11' -0"r SEE NOTE E9 iEE NOTE E10 "sE NOTE E I \ \ \\ U1 CAL \\ T� SEE N E E \ \ SEE FLOOR < \ SOS /CMS CITE E E12 \ \ \\ PLAN NOTE 4 \ SYSTEM 6 7 T2 \\ EE NOTE E4 E AREA \\ T7 EE NOTE E2 \1 U1 SEE FLOOR PLAN NOTE 4 QUAUFIED TECHNICIAN TO PULL CATAGORY 5, 4 PAIR CABLE TO TSB -40 AND EIA/TIA -5688 STANDARDS AT TIME OF ELECTRICAL ROUGH IN, PHONE BOXES TO BE INCLUDED. V1a NETSCREEN ® - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM STARTING CONNECTION Vib RJ45 JACK - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM ENDING CONNECTION V2a NETSCREEN @ - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM STARTING CONNECTION V2b RJ45 JACK - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM ENDING CONNECTION Via NETSCREEN ® - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM STARTING CONNECTION V3b RJ45 JACK - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM ENDING CONNECTION V40 NETSCREEN IS - FUTURE EXPANSION STARTING CONNECTION ' V4b RJ45 JACK - FUTURE EXPANSION ENDING CONNECTION V50 NETSCREEN 14 - COLOR COPIER RIP DEVICE STARTING CONNECTION V5b RJ45 JACK - COLOR COPIER RIP DEVICE ENDING CONNECTION t V6a NETSCREEN ® - DOTAL COPIER STARTING CONNECTION V6b RJ45 JACK - DIGITAL COPIER ENDING CONNECTION V7a NETSCREEN 14 DEDICATED COMPUTER RENTAL LINES STAR71NG CONNECTKN V7b RJ45 JACK - DEDICATED COMPUTER RENTAL ONES ENDING CONNECTION V80 NETSCREEN @ - BACK OFFICE COMPUTER STARTING CONNECTION V8b RJ45 JACK - BACK OFFICE COMPUTER ENDING CONNECTION V9a NETSCREEN 14 - OPTIONAL FAX NETWORK STARTING CONNECTION V9b RJ45 JACK - OPTIONAL FAX NETWORK ENDING CONNECTION V1 Da NETSCREEN tn4 - OPTIONAL NETWORK STARTING CONNECTION V10b RJ45 JACK - OPTIONAL NETWORK ENDING CONNECTION RICK Z. SMITH cYC ASSO CIATES a Rick Zane Smith Florida Reg No. 10,527 P.O. Box 262197 Tampa, Florida 33685 -2197 Tel (813) 901 -9663 Fax (813) 855 -1135 EMAIL rzs @rzsarchitects.com AA 000 2246 Consultant C F - - --7 T2 I alta 4 CAR ETEIB I PAC SURF G — — _J _ T RETAIL UNIT E LECTRICAL AL. laid r Et. STANDARD 200 AMP ELECTRICAL PANEL MINIMUM. E2. LOCATION OF ELECTRICAL OUTLETS ARE APPROXIMATE. E3. USE EXISTING OUTLETS IF CLOSE TO LOCATIONS SHOWN E4. ELECTRICAL OUTLETS ARE AT 14' ABOVE FINISHED FLOOR UNLESS NOTED OR REQUIRED OTHERWISE. E5. USE DEDICATED OUTLET FOR COPIER, AND POS /CMS STATIONS. E6, REMAINING OUTLETS SHOULD BE ON AT LEAST TWO CIRCUITS. DUPLEX OUTLET: 40 DEDICATED DUPLEX OUTLET: 40 4 -PLEX OUTLET: 40 DEDICATED 4 -PLEX OUTLET. 40 E7. ELECTRICAL. AT BACK COUNTERS TO BE BELOW COUNTER TOPS WITHIN WALL E8. ELECTRICAL AT MAIN COUNTER TO RUN THROUGH MOUSE HOLES SEE NOTE E9 WITHIN THE BASE AREA. ACCESS TO OUTLET'S WITH 2' D. HOLES IN E NOTE E10 COUNTER TOP SURFACES, USE PLASTIC GROMMET COVERS TO HIDE PLUG RUNS. E9. ELECTRICAL OUTLET OR JUNCTION BOX FOR RETAIL DISPLAY AT 92' AFF (NON 24 HR. CIRCUIT). E10. OUTLET AT CEILING FOR WINDOW SIGNAGE. EXISTING STOREFRONT LAYOUT TO BE VERIFIED ON SITE FOR OUTLET PLACEMENT. E11. JUNCTION BOX FOR UNDER COUNTER CABINET LIGHTING. E12. ELECTRICAL TRENCH TO BE SAW CUT IN CONCRETE SLAB BY OWNER /CONTRACTOR FOR POWER TO FRONT COUNTERS. FIELD VERIFY LOCATION AND APPROVED BY LANDLORD AND /OR LOCAL MUNICIPALITY. E13. DEDICATED JUNCTION BOX FOR THE ATTACHMENT OF A WHIP TO THE ELECTRICAL BOX WHICH NEEDS TO BE INSTALLLED IN THE COPY TRIANGLE E14. OPTIONAL CEILING MOUNTED DUPLEX OUTLET FOR THE FLO -VAC TYPE EE NOTE E4 ALTA PACK. E15. ELECTRICAL OUTPUT AND PLUG CONFIGURATIONS DRAWN AT COPIERS MAY NOT REFLECT MANUFACTURERS REQUIREMENTS. PLEASE CONTACT THE MANUFACTURERS FOR THE TYPE OF ELECTRICAL RECEPTACLES AND SPECIFIC REQUIREMENTS FOR THE INDIVIDUAL COPIER MODELS BEING USED IN YOUR CENTER. E16. EXTERIOR SIGN JUNCTION BOX LOCATED AT STOREFRONT TO BE SUPPLIED BY DEDICATED CIRCUT FROM BREAKER PANEL WITHIN THE STORE. THE EXTERIOR SIGN INSTALLER WILL ONLY WIRE 3' -0" INTO STOREFRONT FOR CONNECTION TO SERVICE. E17. REQUIRED EXTERIOR SIGN TIMER SHOULD BE SET TO TURN ON AT DUSK AND OFF AT 11:00 PM UNLESS OTHERWISE MANDATED BY LANDLORD. E18. PHOTOCELL TIMER OPTIONAL FOR EXTERIOR SIGN AND REQUIRES FRANCHISEE AUTHORIZATION. E19. TRACK LIGHTING TO UTILIZE HARD WIRE APPUCAT10N TO BE ON A NON 24HR. LIGHTING CIRCUIT. E20, OUTLET 0 86' AFF FOR THE WIFI WAYPORT /ACCESS POINT. E21.ALL TRACK LIGHTING HEADS SHOULD BE DIRECTED TOWARDS THE POP MATERIAL HUNG ON THE CUBEWALL ABOVE THE FIXTURES. — SIEE NOTE E i \\ G4 2b L4 V4 \\ T ' 9 SEEN EE \\ SEE CITE E12 \ POS /CMS 0 \\ SYSTEM I \\ \ r it �r ♦ -- • L4 FLOOR PLAN NOTES 1. OVERHEAD OR SLIDING SECURITY GATE TO BE ORDERED BY FRANCHISE OWNER /AREA FRANCHISEE FROM THE MBE APPROVED VENDOR.. USE FORMS PROVIDED BY YOUR DESIGNER IN YOUR CONSTRUCTION) DOCUMENTS PACKET 2. SLIDING GATE IN LOBBY AREA WILL LOCK DOWN AT FLOOR AND CEILING. 3. MODULAR WALL TO BE SUPPORTED ON SITE BY OWNER/CONTRACTOR. 4. SUN SOLUTIONS BLOCK OUT FILM PER MBE SPECIFICATION$. 5. WINDOW SIGNS TO BE HUNG AT 6' -0' AFF TO BOTTOM OF SIGN. 6. SAND DOWN EDGE BANDING ON THE OUTSIDE EDGE OF THE CABINET LOCATED AT THE OF FRONT COUNTER RUN. 7. SUPPORT COUNTER TOP WITH METAL 'L' BRACKETS. COPIER REQUIRFEMEN 3 ELECTRICAL OUTPUT AND PLUG CONFIGURATIONS DRAWN AT COPIERS MAY NOT REFLECT MANUFACTURERS REQNREIMENTS. PLEASE CONTACT THE MANUFACTURERS FOR THE tYPE OF ELECTRICAL RECEPTACLES AND SPECIFIC REQUIREMENTS FOR THE INDIVIDUAL COPIER MODELS BEING USED IN AR CENTER. 9'-23/4" 6' - 0 " ELECTRICIAN TO PULL 6 PAIR CABLE AT TIME OF ELECTRICAL ROUGH IN, PHONE BOXES TO BE INCLUDED. JACK WIRING AND INSTALLATION TO BE PERFORMED BY QUALIFIED TECHNICIAN. DRAWING BASED ON USING PANASONIC MODELS KX -T3130 8A. KX -3203 OR EQUAL. N 0- R-T H 1 - Electrical Po wer /Data Plan Scale: 1/4" = 1' -0" a L1 RJ14C JACK - VOICE TELEPHONE LINE (PRIMARY) a L2 RJ14C JACK - VOCE TELEPHONE LINE (ROLL -OVER) a Li/L2 RJ14C JACK - VOICE TELEPHONE LINE (PRIMARY & ROLL-OVER) a L3 RJ11C JACK - FAX LINE /POSTAGE METER a L4 RJ11C JACK - CPU BACK -UP LINE (OPTIONAL) a LS RA IC JACK - CUSTOMER (RESTRICTED ACCESS) VOICE LINE (OPTIONAL) SEE FLOOR--, NIGHT LOBBY Ceiling Ht. 11' —O'� 1 NIGHT LOBBY Ceiling Ht. 11' -0"r SEE NOTE E9 iEE NOTE E10 "sE NOTE E I \ \ \\ U1 CAL \\ T� SEE N E E \ \ SEE FLOOR < \ SOS /CMS CITE E E12 \ \ \\ PLAN NOTE 4 \ SYSTEM 6 7 T2 \\ EE NOTE E4 E AREA \\ T7 EE NOTE E2 \1 U1 SEE FLOOR PLAN NOTE 4 QUAUFIED TECHNICIAN TO PULL CATAGORY 5, 4 PAIR CABLE TO TSB -40 AND EIA/TIA -5688 STANDARDS AT TIME OF ELECTRICAL ROUGH IN, PHONE BOXES TO BE INCLUDED. V1a NETSCREEN ® - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM STARTING CONNECTION Vib RJ45 JACK - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM ENDING CONNECTION V2a NETSCREEN @ - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM STARTING CONNECTION V2b RJ45 JACK - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM ENDING CONNECTION Via NETSCREEN ® - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM STARTING CONNECTION V3b RJ45 JACK - CUSTOMER MANAGEMENT SYSTEM /POINT OF SALE SYSTEM ENDING CONNECTION V40 NETSCREEN IS - FUTURE EXPANSION STARTING CONNECTION ' V4b RJ45 JACK - FUTURE EXPANSION ENDING CONNECTION V50 NETSCREEN 14 - COLOR COPIER RIP DEVICE STARTING CONNECTION V5b RJ45 JACK - COLOR COPIER RIP DEVICE ENDING CONNECTION t V6a NETSCREEN ® - DOTAL COPIER STARTING CONNECTION V6b RJ45 JACK - DIGITAL COPIER ENDING CONNECTION V7a NETSCREEN 14 DEDICATED COMPUTER RENTAL LINES STAR71NG CONNECTKN V7b RJ45 JACK - DEDICATED COMPUTER RENTAL ONES ENDING CONNECTION V80 NETSCREEN @ - BACK OFFICE COMPUTER STARTING CONNECTION V8b RJ45 JACK - BACK OFFICE COMPUTER ENDING CONNECTION V9a NETSCREEN 14 - OPTIONAL FAX NETWORK STARTING CONNECTION V9b RJ45 JACK - OPTIONAL FAX NETWORK ENDING CONNECTION V1 Da NETSCREEN tn4 - OPTIONAL NETWORK STARTING CONNECTION V10b RJ45 JACK - OPTIONAL NETWORK ENDING CONNECTION RICK Z. SMITH cYC ASSO CIATES a Rick Zane Smith Florida Reg No. 10,527 P.O. Box 262197 Tampa, Florida 33685 -2197 Tel (813) 901 -9663 Fax (813) 855 -1135 EMAIL rzs @rzsarchitects.com AA 000 2246 Consultant C ono N t� rRACK Li rmrm SEE NOTE E4 l qz TI 2'TRACK T2 V TRACK T3 6' TRACK T4 8 TRACK TS CONNECTOR T6 r� T7 HEADS i--�I t A ono N t� rRACK Li rmrm SEE NOTE E4 l qz TI 2'TRACK T2 V TRACK T3 6' TRACK T4 8 TRACK TS CONNECTOR T6 END CAP T7 HEADS 1-IGHTIN USE EXISTING LIGHTING FIXTURES WHEREVER POSSIBLE, RELOCATION OF FIXTURES MAY BE REQUIRED BASED ON LOCATION OF WALLS BEING ADDED. ADDITIONAL LIGHT FIXTURES MAY BE REQUIRED TO PROPERLY LIGHT AREAS AFFECTED BY NEW CONSTRUCTION. RULE OF THUMB FOR PROPER LIGHT FIXTURE COUNT: ONE 2 X 4 FIXTURE PER 70 SQ. FEET OF MBE CENTER. FIXTURES SHOULD BE RECESSED 4 LAMP FLUORESCENT. NOTE: 24 HR. DEDICATED LIGHT FIXTURES TO BE SWITCHED OFF AT SUB -PANEL N 0- &_ H 2 - Lighting Plan Scale: 1/4" = 1' -0" SEE NOTE E4 SEE FLOOR PLAN NOTE C= �\ �b�° U1 t *t 11 U1 — -� 1� / SEE FLOOR J PLAN NOTE 4 EE NOTE E4 SEE FLOOR U PLAN NOTE 4 U1 Drawing Date: 2 -12 -10 Project Number 1003 Drawn By: MC Checked By: RZS Sheet Title Power Plan Lighting Plan Sheet Number A2,012