Loading...
HomeMy WebLinkAbout10-10587 CITY OF ZEPHYRHILLS 5335 - 8TH STREET • (813)780 -0020 10587 FIRE SPRINKLER SYSTEM PERMIT Permit Number: 10587 Address: 7850 GALL BLVD Permit Type: FIRE SPRINKLER SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE - SPRINKLER SYS Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 35- 25 -21- 0130 - 00000 -0140 Improv. Cost: 3,000.00 , :; - _ ' Date Issued: 6/14/2010 Name: ZEPHYR COMMONS LLC Total Fees: 260.00 Address: 3629 MADACA LANE Amount Paid: 260.00 TAMPA FL 33618 Date Paid: 6/14/2010 Phone: (813)927 -0011 Work Desc: INSTALLATION FIRE SPRINKLER LIQUIOR STORE BUILD OUT A ■ I ■ 'I IN 1'E " INK . 50.00 1' 'LAN IEW 100.00 FIRE INSPECTION FEES 110.00 (C---, i i Of Ke' � / _, iii _` . iR / , 1 / 5D FIRE ACCEPTANCE Final Chapter 633, Florida Statutes, authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees, and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of $100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." CONTRA R SIGNATURE - _d I 7 — IC R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT - Fire Marshal Office - 813- 780 -0041 813 -780 -0020 City of Zephyrhills -Fire #08 1 Fax -813- 780 -0021 Permit Application Date Received 0 — 0 Phone Contact for Permit Ei 33 73'3 Owner' Name fr L-- e l . G l [..L a- Owner's Phone Number Owners Address Fee Simple Name Titleholder Phone Number Fee Simple Titleholder Address J /� ` Job Address `� g 5(9 G r LV p — A/,1- i ' S (..ter QuA2- Lot* Sub Division ) M{(-- Co /4/1(Q /L s Parcel # Bio- Hazard Waste Storage - ANNUAL n Fumigation Tent I Comm Exhaust Kitchen Hood /Duct n Hazardous Material (Tier II or RQ Facility) ANNUAL F - 7 Controlled Bum n Hood Installation I —I Emergency Generator < 30 kw n LP /Natural Gas - Installation I I Emergency Generator> 30 kw n LP /Natural Gas - ANNUAL Sale I Fire Protection Maintenance - ANNUAL n Places of Assembly- ANNUAL ILttrly1 JSemi1 FAT1 uttter Sprinkler n ❑ ❑ ❑ ( ( Recreational Bum Fire Alarrn n ❑ ❑ ❑ I n Sparklers n Hood Cleaning ❑ ❑ ❑ I ( Sprinkler System Installations Hood Suppression El ❑ ❑ ❑ I 1 n Standpipes (Sprinkler Sys) n Fire Alarm Installation I I Torch Roofing/Tar Kettle n Fire Pumps n Waste Tire Storage ANNUAL n Fire Works n Flammable Application- ANNUAL 1 431090-00 I Valuation of Project Fuel Tanks Q Other: I Contractor /J /� Company Cc7 . OG' 7 iZI /ES Signature �"'� - Registered (s N . 1 Fee Current I CP/ N Address I e441 r 4- z/sl4,7 Di. t -7--",.)4,404 l '? c. /g I License# /4 r .;f / ELECTRICIAN Company Signature Registered Y/ N J Fee Current I Y/ N I Address 1 I License # I PLUMBER Company Signature Registered Y/ N I Fee Current I Y / N, Address I I License # J I MECHANICAL Company Signature Registered Y/ N I Fee Current 1 Y / N j Address I I License # I OTHER Company Signature Registered Y/ N . 1 Fee Current I Y/ N i Address License Directions: .. Fill out application completely. Owner & Contractor sign back of application, notarized (Or, copy of signed contract with owner) If over $2500, a Notice of Commencement is required. (Mechanical work over $5000) Supply two (2) sets of drawings with applicable documentation Allow 10 - days for review after submittal date. Parcel # - obtained from Property Tax Notice (http: / /appraiser.pascogov.com) .NOTICE OF 'DEED RESTRICTIONS: The undersigned understands that this permit maybesubjectto "deed °:restrictions which may be more restrictive than County regulations. The undersigned assumes responsibility for:compliance any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has - hired - :a - contractor:or contractors to undertake work, they may be required to be licensed in accordance with state and local If the contractor is not licensed as required by law, both the owner and contractor may be cited - for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may :apply for the intended work, they are advised to contact the Pasco County Building Inspection Division — Licensing Sectionat 727 -847- 8009. Furthermore, if the owner has hired .a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as . the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled permitting privileges in Pasco County. CONSTRUCTION. LIEN LAW (Chapter713, Florida Statutes, as :amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law — Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner ", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S /OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A 'NOTICE 'OF 'COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT (F.S. 117.03) 'X.-47N OR AGENT CONTRACTOR Subscribed and sworn t� (or affirmed) before me this Subscribed and sworn to.(or affirmed) fo e this — - by by /"/I.b21`"7") iS 6 L- tc!!l Who is/are personally known to me or has/have produced Who is /are personally known to me or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed, printed or stamped Name of Notary typed, printed or stamped Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (813) 780 -0041 Kerry Barnett Fax (813) 780 -0044 E -mail: kbarnett a fire.zephyrhills.fl.us Plan Review #: 10 -068 Project: Sprinkler Modification Number of Pages: 1 plus Packet June 14, 2010 I have received and reviewed the revised plans for the fire sprinkler modification located at 7850 Gall Blvd and will allow the project to move forward. Please note that this review does not eliminate any further requirements as the project continues moving forward. By receiving permit, contractor acknowledges to comply with the items listed below. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. 1. Modification/installation shall be compliant to NFPA 13, 2002 edition. 2. The riser has a 5" storz connection not a double 2 'A" FDC. 3. Any penetrations made to a rated wall ensure it has been sealed in accordance to the submitted plans. Inspections Required: 1. Pressure Test (normal pressure unless it can be isolated) 2. Final. dPvir KERRY,: • ' TT, FIRE MARSHAL ** *Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. • ZEPHYRHILLS FIRE DEPARTMENT •6907 Dairy Road, Zephyrhills, FL 33542 Fire Chief Keith Williams Bus (813)780 -0041 Fax (813)780 -0044 FIRE SERVICE USER FEES Occupancy No.: Plan No.: s& — 068 Contractor: Gc}ps'ep Business Name: ‘S L ► Ahi 4 - cam Billing Address: $4 4S EAST" A -6AM.° A 2 Business Address: '?¢3 0 GINAN ` 3 hS+n T/ln, "if 1 FL 336r5 Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES _ INSPECTION FEES A PERMIT FE _ FALSE ALARM FEE _ Site Plan N/C _Annual N/C 3 Sprinkler $5 _ 1st Alarm N/C Multi- Family /Commercial .06 sf _ 1st Re- inspection N/C 1 Standpipes _ 2nd Alarm N/C (Minimum Charge $25.00 _ 2nd Re- inspection $100 1 Fire Pump $50 _ 3rd Alarm N/C D Plan Revisions DBL _ 3rd Re- inspection $250 , Hoods $50 _ 4th Alarm $100 4th Re- Inspection $500 , Fire Alarm $50 _ 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until , LP Gas $50 _ 6th Alarm $200 p. 0 - 25 Heads $50 violations corrected) Natural Gas NON COMPLIANCE $150 26 plus Heads 00 ) SPRINKLER SYSTEMS ,Fuel Tanks- per tank $50 $50 STANDPIPE SYSTEM Hydro Undergrounds 4545 , Sparklers $100 0 Per Riser $50 Hydrostatic Test per system 1 Fire Works $500 FIRE PUMP Acceptance Test P per system 1 Camp Fire $25 0 Per Pump $100 Hydrant Flow $75 , Controlled Burn $100 FIRE ALARM SYSTEM 1 Hood /Duct $50 0 - 25 Devices $50 _ FIRE ALARM SYSTEM II Place of Assembly $50 Annual 26 plus Devices $100 _ System Acceptance $50 , Fire Protection $25 _ SUPPRESSION SYSTEMS _ Recall Acceptance $50 II Flammable Application $50 Annual — Wet $50 _ OTHER 1 Waste Tire Storage $50 Annual Dry $50 _ Fire Wall /Smoke Wall $15 per wall , Generator < KW $100 — CO2 $50 _ LP Gas $25 per tank 1 Generator >30 KW 150 Other $50 ` Natural Gas $25 per system 1 Bio -Hazard Waste $100 Annual KITCHEN EXHAUST _ ■ Fumigation Tenting $50 0 Hood /Ducts $50 _ Tent 10'x10' or greater $15 per tent II Torch Pot/Applied $50 OTHER _ Fire Pump $45 , Haz. Materials $100 Annual LP Installation per tank $50 ` Fire Suppression $30 Fuel Tank Installation $50 _ System Acceptance (Per Tank) $50 _ Exhaust Hood /Duct $30 El Natural Gas Installation $50 Re - inspection DBL (Per System) (other than annual) _ Spray Booth $50 0 Inspection scheduled DBL _ and cancelled less than _ _ 24 hours _ Construction Insp. N/C — 1117 Emergency Vehicle Acs $50 —e FALSE ALARM PLANS TOTAL INSPECTION TOTAL PERMIT TOTAL 5 1) TOTAL GRAND TOTAL I e26 0 – Comments: Date: (Al D Inspgctor: liGf 60.yht,44 Capsco Industries 8445 East Adamo Drive Tampa, Florida 33619 Ph: 813- 628 -4700 Fx: 813- 628 -4766 FLORIDA LICENSE NO. 14044500012009 Building Dept. Permit #10491 Equipment Material Submittals for Harry's Liquor at Zephyr Commons 7850 Gall Blvd. (U.S. Hwy 301) Zephyrhills, Florida 33541 Harry's Liquor at Zephyr Commons Tenant Spaces D5 -D6 Equipment Material Submittal Table of Contents Sprinkler Heads & Accessories Manufacturer Model "M" Quick Response (Pendent) Viking Misc. Material Hilti UL Listed Details HILTI FS -ONE Firestop / Sound Stop Sealant HILTI Industrial Bulk Wool Thermafiber Above Ground Piping Fittings Threaded Cast Iron Nipples & Fittings AnvilStar Hangers & Hanger Material 3/8" Universal C -Clamp AnvilStar Intl. Inc. 1" Adjustable Loop Hanger AnvilStar Intl. Inc. 3/8" Zinc Plated All Thread Rod AnvilStar Intl. Inc. Above Ground Piping 1" Sched 40 Pipe (Thrd) Allied Fire Protection Shop Drawing Capsco Industries Under Separate Cover (24 x 36) Capsco Industries 8445 East Adamo Drive, Tampa, FL 33619 Ph: 813 - 628 -4700 Fx: 813 - 628 -4766 ' August 27, 2004 Sprinkler 41 a ® MICROFAS - r & MicrofastHP TECHNICAL DATA QUICK RESPONSE PENDENT SPRINKLERS 1. PRODUCT NAME 12104. Copper UNS- C19500 for Viking Microfast® and MicrofastHP® Sprinkler 12282. Brass UNS- C26000 Model M Quick Response Pendent for all other Part Nos. Sprinklers Bushing (for Sprinkler Base Part Nos. 2. MANUFACTURER 06718B, 06720B, and 12290): Brass UNS- C36000 The Viking Corporation Bulb: Glass, nominal 3 mm diameter 210 N. Industrial Park Road Belleville Spring Sealing Assembly: 11 111A- Hastings, Michigan 49058 U.S.A. Nickel Alloy, coated on both sides Telephone: (269) 945 -9501 with Teflon Tape (877) 384 -5464 Screw: Brass UNS- C36000 Fax: (269) 945 -9599 Pip Cap and Insert Assembly: Copper e -mail: techsvcs @vikingcorp.com UNS- C11000 and Stainless Steel 3. PRODUCT DESCRIPTION 4. TECHNICAL DATA UNS- S30400 Viking Microfast® and MicrofastHPe LISTINGS AND APPROVALS Pip Cap Attachment: Brass UNS- C36000 Quick Response Pendent Sprinklers Refer tothe Approval Charton page 41 b. Ejector Spring (Part No. 12104): Stain are small, thermosensitive spray sprin- Glass -bulb fluid temperature rated to less Steel klers available with several finishes, -65 °F ( -55 °C). Sprinklers with Teflon® Coating temperature ratings, and orifice sizes to Minimum Operating Pressure: 7 psi Belleville Spring: Nickel Alloy, exposed meet design requirements. The special (48,3 kPa) Screw: Brass UNS- C36000, Nickel Poly finishes and Teflon® coatings can RATED WATER WORKING PRES- plated be used in decorative applications SURE Pip Cap: Teflon® Coated where colors are desired. In addition, Sprinklers VK317 and VK342 are Sprinklers with Polyester Coating or these two finishes are corrosion resis- rated for use with water working Poly Finish tant and provide protection against pressures ranging from the mini- Belleville Spring: Nickel Alloy, exposed many corrosive environments. mum 7 psi (48,3 kPa) up to 250 psi (1 AVAILABLE FINISHES The pip cap and sealing assembly of the 724 kPa) for high - pressure sys- Brass, Chrome - Enloy® (patents pend- sprinkler is held in place by a bulb tye terns. High - pressure (HP) sprin- ing), White Polyester (White Poly finish operating element. During fire condi- klers can be identified by locating for Sprinkler 06662B), Black Polyester tions, when the temperature around the the number "250" on the deflector. (Black Poly finish for Sprinkler 06662B), sprinkler reaches its operating tempera- All Other Sprinklers: Maximum 175 and Black Teflorf® ture, the heat - sensitive liquid in the psi (1 207 kPa) wwp. ACCESSORIES glass bulb expands, causing the bulb to Factory tested hydrostatically to 500 psi Sprinkler Cabinets (Available since shatter, releasing the pip -cap and seal- (3448 kPa). 1971): ing spring assembly. Water flowing Testing: U.S.A. Patent No. 4,831,870 A. Six -head capacity: Part No. through the sprinkler orifice strikes the SPRINKLER MATERIALS 01724A sprinkler deflector, forming a uniform Frame: Brass Castings UNS- C84400 B. Twelve -head capacity: Part No. spray pattern to extinguish or control the Deflector: Brass UNS- C51000 or Cop- 01725A fire. per UNS- C19500 for Sprinkler Base Sprinkler Wrenches: Part Nos. 06662B, 06666B, 06765B, A. Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Temperature Nominal Sprinkler Temp. Maximum Ambient Bulb or 05000CW /B (no longer avail - Classification Rating (Fusing Point) Ceiling Temperature Color able). Ordinary 155 °F (68 °C) 100 °F (38 °C) Red B. Wrench for coated and recessed Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Viking Microfast® and MicrofastHP® Intermediate _ 200 °F (93 °C) _ 150 °F (65 °C) Green QR Pendent Sprinklers: Part No. High 286 °F (141 °C) 225 °F (107 °C) Blue 07398W* (available since 1990), Sprinkler Finishes: Brass, Chrome - Enloy® (patents pending), White Polyester (White Poly or Part No. 12144W/B *, available finish for P/N 06662B), Black Polyester (Black Poly finish for P/N 06662B), and Black Teflon® since 2003. NOTE: Recessed Corrosion - Resistant Coatings White Polyester (White Poly finish for P/N 06662B), Black pendent sprinklers with protec- Polyester (Black Poly finish for P/N 06662B), and Black Teflon tive caps must use wrench Footnotes 12144W/B. 1 Based on NFPA -13. Other limits may apply, depending on fire loading, sprinkler location, *A W ratchet is required (not available through and other requirements of the Authority Having Jurisdiction. Refer to specific installation Viking). standards. Refer to the "SPRINKLER ACCES- 2 The temperature rating is stamped on the deflector. SORIES" section of the Viking Engi- The corrosion- resistant coatings have passed standard corrosion tests required by particu- neering and Design Data book. lar approving agencies. Refer to the approval chart on page 41 b. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. The coatings indicated are applied to the exposed exterior surfaces only. NOTE: The spring is exposed on sprinklers with Teflon® Coating or Poly finishes. Note: Units of measure in parentheses may be approximations. Replaces page 41 a -b, dated May 14, 2004 (updated deflector Form No. F_081296 materials). Refer to technical data page QR1 -2 for care, in- stallation, and maintenance information. Sprinkler 41 b August 27, 2004 ® MfCROFAST & MicrofastHP '°(-,HN )4:4 QUICK RESPONSE PENDENT SPRINKLERS Approval Chart 1 Temperature KEY Microfast MicrofastHP Quick Response Finish Pendent Sprinklers Al X.- Escutcheon (if applicable) Maximum 175 PSI WWP Standard • rifice 2 ' - Base Part . ..uI - g• -Mk.. • - I NPT la Number1 SIN U.S. metric = ULus FM NYC VdS LPCB CE 5 Large 0 Tice 3/4" 20 mm 175 06666B VK35 8 0 11.5 2 -3/8 60 A3X B3Y A2X. B2Y A3X. B3Y - - -- '/ " r u nMINVFII=I 7 \N KfANEFINIMiMENFS71IlliMi/:�3.' c37 - LIGKA :161/ - - - Small Orifice '/2' 15 mm 175 06718B VK329 2.8 4.0 2 -3/16 56 A3X. B3Y A2X A3X. B3Y - - -- ' /2' 15 mm 175 06720B VK331 4.2 6.0 2 -1/4 58 A3X. B3Y - A3X. B3Y - - -- - 10 mm 175 069378 VK331 4 2 6 0 2 -3/8 60 - - - C2 - -- Maximum 250 PSI WWP Standard Orifice - - - - Base Part • •:u' i • ..h • • - r - l. I Listings and Apo rovals 2 NPT BSP Number1 SIN - - Inches mm cULus FM NYC VdS LPCB C ' " 1 n u • 1 17 : - /4 58 A3X. B3Y - A3X - - -- SmaII • rifice ' " EM1111111111111Ma51111117NMFZIEMISEMIRREMIMIIIIPAcismfA - M - - -- Approved Finishes Approved Escutcheons Approved Temperature Ratings >> X- Standard mountedescutcheon 1- Brass, Chrome - Enloe', White Poly , Finish , Black or the Viking Microfast Model F -1 Ad- A - 155 °F (68 °C), 175 °F (79 °C), 200 °F Poly Finish and Black Teflon i1 io (93 °C), and 286 °F (141°C) 2 - Brass and Chrome-Enloe justable Escutcheon 10 -155 °F (68 °C), 175 °F (79 °C), and 200 °F 3 - Brass, Chrome - Enloe White Polyester Black Y - Standard surface -mount ® escutch- �� ®11 eon or the Viking Microfast Model F -1 (93 °C) Polyester 11 , and Black Teflon Adjustable Escutcheon or recessed C - 155 °F (68 °C) 4 - Brass, Chrome -Enloe , White Poly Finish, and with the Vicing Micromatic Model E -1 or Black Poly Finish E -2 Recessed Escutcheon Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 3 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219- 76 -SA. 4 The sprinkler orifice is bushed. 5 (E Certified, Standard EN 12259 -1, EC- certificate of conformity 0832 -CPD -2001. 6 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 7 cULus Listings and NYC Approvals limited to Light- Hazard Occupancies with hydraulically calculated wet systems. 8 Metric K- Factor shown is for use when pressure is measured in kPa. When pressure is measured in BAR, multiply the metric K- Factor shown by 10.0. 9 FM Approved for use only in wet -pipe sprinkler systems (or preaction systems qualifying as wet systems) for protection of occupancies de- scribed in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and Technical Advisory Bulletins. 10 The Viking Microfast Model F -1 Adjustable Escutcheon is considered a surface- mounted escutcheon because it does not allowthe fusibleele- ment of the sprinkler to be recessed behind the face of the wall or ceiling. 11 cULus Listed as corrosion resistant. 12 Accepted for use, City of New York Department of Buildings, MEA 89 -92 -E, Vol XVI. 13 Refer to the "Sprinkler Accessories" section of the Viking Engineering and Design Data book for technical data on approved escutcheons and other accessories. Quick Response Pendent Sprinkler 2-1/8" with a Standard 1/8" (3,1 mm) (54 mm) 1. 2 -1/8" :face-Mounted Escutcheon (54 mm) 1 111111 �i� -^��� x Zuxuo�- {$is£�SS �xa x�i £ s £ x,xa�t 2 -1/4° .. � M� � rt i r I : t � 0I MI »ti r ; (58 mm) ° If I- !'' ,` x x ; W 2 " I III 1 - 1/2" (32 mm) 1 -3 4" ( 51 mm) I. Minimum -1/ 1 mm ) ■ j = / Maximum ` t -3/4" �.r ( (45 mm) j (45 mm) 0 28 mum 6 1 _ ,�., Maximum a Quick Response 1 Pendent Sprinkler Quick Response Pendent Sprinkler '°......° Installed with the Viking Microfast Model F -1 Adjustable Escutcheon Quick Response Pendent Sprinkler Ceiling Opening Size: 2-5/16" (59 mm) Minimum, Installed with the Viking Micromatic 2 -1/2" (64 mm) Maximum. Model E -1 Recessed Escutcheon Figure 1 Replaces page 41 a -b, dated May 14, 2004 (updated deflector materials). Refer to tech- Form No. F_081296 nical data page QR1 -2 for care, installation, and maintenance information. • 1114II_11 i idtt. Uu11, rk;rm t )t II ), t. Firestop Submittal 800-879-8000 www.hilti.us Sprinkler Submittal: Flat Concrete Metallic & Combustible Penetrants (Cast -In Option) Barrier Penetration Type Max. Penetration Size Annular Space F- Rating System Product Number Steel, Cast Iron, Floor Copper, Steel Conduit, 4" EMT; 6" others (See Detail) 3 hours F -A -1017 CP 680P / M; EMT CP 618 Floor PVC, CPVC, RNC 6" all See Detail 3 hours F -A -2054 CP 680P Floor ABS, FRPP 4" ABS; 6" FRPP See Detail 3 hours F -A -2066 CP 680P Barrier Penetration Type Max. Penetration Size Annular Space F- Rating System Product Number Steel, Cast Iron, 30" Steel or Cast Iron; Wall Copper, Steel Conduit, 6" Copper or Steel 0" to 2 -1/4" 1 or 2 hours W -L -1054 FS One EMT Conduit 4" EMT PVC, CPVC, ABS, 10" PVC or CPVC; 6" FS One; CP Wall FRPP, PVDF ABS or FRPP; 4" PVDF 0" to 1/2" 1 or 2 hours W -L -2078 643N or CP 644 Wall PVC, CPVC 2" either 1/4" to 11/16" 1 or 2 hours W -L -2128 FS One Barrier Penetration Type Max. Penetration Size Annular Space F- Rating System Product Number Steel, Cast Iron, 30" Steel or Cast Iron; Floor / Wall Copper, Steel Conduit, 6" Copper or Steel 0" to 1 -7/8" 3 hours C -AJ -1226 FS One EMT Conduit 4" EMT 6" and smaller PVC, CPVC, ABS, 10" PVC or CPVC; (0" to 1/2 "); CP 643; or Floor / Wall 2 or 3 hours C -AJ -2109 CP 644• FS FRPP 6" ABS or FRPP larger than 6 ": 0" to 1 -1/4" One Floor / Wall PVC, CPVC 3" either 1/2" to 2" 3 hours C -AJ -2141 FS One; CF 810 orCF8l2 Barrier Penetration Type Max. Penetration Size Annular Space F- Rating System Product Number Steel, Cast Iron, 30" Steel or Cast Iron; Wall Copper, Steel Conduit, 6" Copper or Steel 0" to 2 -1/4" 1 or 2 hours W -J -1067 FS One EMT Conduit- 4" EMT Wall PVC, CPVC 2" either 1/4" to 11/16" 1 or 2 hours W -J -2108 FS One UUcUL SYSTEM NO. W -L -1054 METAL PIPE THROUGH 1 -HR. OR 2 -HR. GYPSUM WALL ASSEMBLY F- RATING = 1-HR. OR 2 -HR. o ° T- RATING = 0 -HR. L- RATING AT AMBIENT = LESS THAN 1 CFMISQ. FT. L- RATING AT 400 °F = 4 CFM/SQ. FT. FRONT VIEW o SECTION A -A 0 A © 1114111:1 0 7 0 A 1. GYPSUM WALL ASSEMBLY (UL/ULC CLASSIFIED U300 OR U400 SERIES) (1 -HR. OR 2 -HR. FIRE - RATING) (2-HR. SHOWN). 2. (NOT SHOWN). WOOD STUDS TO CONSIST OF NOMINAL 2" x 4" LUMBER. STEEL STUDS TO BE MINIMUM 2-1/2" WIDE. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 30" DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER). B. MAXIMUM 30" DIAMETER CAST IRON PIPE. C. MAXIMUM 6" NOMINAL DIAMETER COPPER PIPE. D. MAXIMUM 6" NOMINAL DIAMETER STEEL CONDUIT. E. MAXIMUM 4" NOMINAL DIAMETER EMT. 4. MINIMUM 5/8" DEPTH HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT. 5. MINIMUM 1/2" BEAD HILTI FS -ONE INTUMESCENT FIRESTOP SEALANT AT POINT OF CONTACT. NOTES : 1. MAXIMUM DIAMETER OF OPENING : A. 32 -114" FOR STEEL STUD WALLS. B. 14-1/2" FOR WOOD STUD WALLS. 2. ANNULAR SPACE = MINIMUM 0 ", MAXIMUM 2-1/4". 3. PIPE MAY BE INSTALLED WITH CONTINUOUS POINT OF CONTACT. 4. PIPE MAY BE INSTALLED AT AN ANGLE NOT GREATER THAN 45° FROM PERPENDICULAR. Sheet 1 of 1 Drawing No C Dr' J LJ HILTI, Inc. Scale 7132" = wL Tulsa, Oklahoma USA (918) 252 -6000 1054q FIRESTOP SYSTEMS Date Nov. e, 2002 Saving Lives through Innovation and Education 11.11,1■11 Product Information FS -ONE • • Product description FS -ONE • Intumescent (expands when exposed to fire) firestop sealant High Performance that helps protect combustible and non - combustible penetra- Technical Data • lions for up to 4 hours fire rating At 73 °F (23 °C) and 50% relative humidity Intumescent Firestop Product features Chemical basis Sealant • Smoke, gas and water resistant after material has cured Water -based intumescent acrylic dispersion • Contains no halogen, solvents or asbestos Density • High fire rating properties Approx. 1.5 q /cm • Water based, easy to clean Color ' Red - Areas of application • Steel, copper and EMT pipes working t- 30 Approx. 20-30 min. =, • Insulated steel and copper pipes Curing time • Cable bundles Approx. 4 mm / 3 days - I s • Closed or vented plastic pipes Shore A Hardness System / � 'B • HVAC p Approx. 35 • l cop For use with Movement capability penetration tions • Concrete, masonry, drywall and wood floor assemblies Approx. 5% • Easy to work with and fast clean • Wall and Floor assemblies rated up to 4 hours Intumescent Activation • Can be painted ! Approx 482 °F (250 °C) • Single component systems available Exam Expansion rate (unrestricted): • Meet3 kEth"" • Sealing around plastic pipe penetrations in fire rated Up to 3 -5 times original volume credit 4.1 Loin+ construction Temperature resistance (cured) ,, , , , • Sealing around combustible and non - combustible -40 °F to 212 °F ( -40 °C to 100 °C) - Adhes and" 4,2 PKs at` penetrations in fire rated construction Application temperature i- 41 °F to 104 °F (5 °C to 40 °C) c - 3 Installation instructions for FS -ONE Surface burning characteristics Opening Notice about approvals (ASTM E 84 -96) z 1. Clean the opening. Surfaces to which FS -ONE will be • Check that the penetration has been sealed according to Flame Spread: 0 N applied should be cleaned of loose debris, dirt, oil, the specified drawing in the UL Fire Resistance Directory Smoke Development: 5 moisture, frost and wax. Structures supporting or Hilti Firestop Manual. For further advice, please Sound transmission classification o penetrating items must be installed in compliance with contact Hilti customer service. Refer to Hilti product (ASTM E 90 -99) 56 0 local building and electrical standards. literature and UL fire resistance directory for specific n application details. Approvals n Application of firestop sealant ICBO (International Conference of 2. Install the prescribed backfilling material type and depth Not for use... Building Officials) to obtain the desired rating (if required). Leave sufficient • High movement expansion joints Report No. 5071 depth for applying FS -ONE. • Underwater California State Fire Marshal 3. Application of firestop sealant: Apply FS -ONE to the • On materials where oil, plasticizers or solvents may Listing No. 4485 - 1200:108 required depth in order to obtain the desired fire rating. bleed i.e. impregnated wood, oil based seals, green or City of New York Make sure FS -ONE contacts all surfaces to provide partially vulcanized rubber Y maximum adhesion. For application of FS -ONE use a • In any penetration other than those specifically MEA 326-96-M standard caulking gun, foil pack gun, bulk loader and described in this manual or the test reports bulk gun. With FS -ONE buckets, Graco type sealant Safety precautions Tested in accordance with pumps may be used. (Contact pump manufacturer for . Before handling, read the product and Material Safety • UL 1479 proper selection). Data Sheet for detailed use and health information • ASTM E 814 4. Smoothing of firestop sealant: To complete the seal, tool • Keep out of reach of children • ASTM E 84 immediately to give a smooth appearance. Excess • Wear suitable gloves and eye protection sealant, prior to curing, can be cleaned away from Stora a Internationally tested and approved adjacent surfaces and tools with water. g • Store only in the original packaging in a location "*s81F,4' FlLL, VOID OR CAVITY MATERIAL 5. Leave completed seal undisturbed for 48 hours. protected from moisture at temperatures between ° FOR USE I IN Tw sY - PENETRATION 6. For maintenance reasons, a penetration seal could be 40 °F (5 °C) and 86 °F 30 °C C )� SEE UL FIRE sESS RESISTANCE DIRECTORY (30°C) `J RECTORY permanently marked with an identification plate. In such • • Observe expiration date on the packaging 66Y7 a case, mark the identification plate and fasten it in a visible position next to the seal. ri APPROVED n �.. "'" APPROVED COY ►ATtilf iii . 11F IL 7 1. Clean opening. 2. Pack mineral 3. Apply FS -ONE. 4. SmooNE. 5. Leave completed 6. Fasten identifi- _ _ H H.. wool. (!f required) seal undisturbed for cation plate (if 48 hours. required). E3 latest product information : ,, www.us.hilti,com ,.i.r, [ 1 4, -4-70 1 ,:_, .., F I [ 1 [ El ordering information see page: _ i 1. Clean opening. 2. Pack mineral 3. Apply FS -ONE. 4. Smooth FS -ONE. 5. Leave completed 6. Fasten identifica- 34 wool (If required) seal undisturbed for tion plate (if Saving Lives through innovation & education 1 Hilti Firestop Guide /A ` -2006 1 1- f79 -8000 1 www.us.hilti.com 1..4/`•I ° 17 Material Safety Data Sheet I MSDS No.: 259 Revision No.: 010 Revision Date: 08/17/04 Page: 1 of 2 Product identifier: FS -ONE High Performance Intumescent Firestop Sealant Description: One -part acrylic -based sealant Supplier: Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121 Emergency # (Chem - Trec.): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) INGREDIENTS AND EXPOSURE LIMITS • Ingredients: CAS Number: PEL: TLV: STEL: Polyacrylate dispersion Mixture NE NE NE - Calcium carbonate 001317 -65 -3 5 mg /m (T) 10 mg /m (T) NE Zinc borate 138265 -88 -0 NE NE NE Ammonium polyphosphate 068333 -79 -9 NE NE NE Talc 014807 -96 -6 20 mppcf 2 mg /m' NE Expandable graphite 012777 -87 -6 5 mg /m' (T) 2 mg /m (T) NE Ethylene glycol 000107-21-1 NE C:100 mg /m' (A) NE Polybutene 009003 -29 -6 NE NE NE • Iron oxide 001309 -37 -1 10 mg /m' 5 mg /m NE • Glass filament 065997 -17 -3 NE 5 mg /m (T) NE Silicon dioxide 014808 -60 -7 0,05 mg /m' (T) 0.1 mg /m (T) NE Water 007732 -18 -5 NE NE NE - Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. C = Ceiling. STEL = Short Term Exposure Limit. NE = None Established. NA = Not Applicable. (1) indicates "as total dust ". (R) indicates "as respirable fraction". (A) indicates "as an aerosol ". mppcf = million particles per cubic foot. PHYSICAL DATA Appearance: Red paste. Odor: Odorless. Vapor Density: (air = 1) Not determined. Vapor Pressure: 23mbar @ 20C / 68F Boiling Point: Not applicable. VOC Content: 75.0 g /L. Evaporation Rate: Not applicable. Solubility in Water: Soluble. Specific Gravity: 1.5 pH: Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Non - flammable. Flammable Limits: Not applicable. - Extinguishing Media: Not applicable. Use extinguishing media as appropriate for surrounding fire. Special Fire Fighting Procedures: None known. Use a self- contained breathing apparatus when fighting fires involving chemicals. Unusual Fire and Explosion Hazards: None known. Thermal decomposition products can be formed such as oxides of carbon, sulfur and phospho- rous. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. e Incompatibility: Strong acids, peroxides, and oxidizing agents. o Decomposition Products: Thermal decomposition can yield CO and CO2. v Conditions to Avoid: None known. w HEALTH HAZARD DATA v; Known Hazards: None known. a Signs and Symptoms of Exposure: Possibly irritating upon contact with the eyes or upon repeated contact with the skin. 1- Medical Conditions Aggravated by Exposure: Eye and skin conditions. z Routes of Exposure: Dermal. a s Carcinogenicity: IARC classifies crystalline silica (quartz sand) as Group 1 based upon evidence among workers in industries where there has been long -term and chronic exposure (via inhalation) to silica dust; e.g. mining, quarry, stone w crushing, refractory brick and pottery workers. This product does not pose a dust hazard; therefore, this clas- sification is not relevant. Based upon the nature and intended use of this product, it does not pose an increased cancer risk to workers. 454 1■11`TI • Saving Lives through innovation & education I Hilti Firestop Guide 2005 -2006 1 1 -800- 879 -8000 I www.us.hilti.com ,liorr Material Safety Data Sheet • MSDS No.: 259 Revision No.: 010 Revision Date: 08/17/04 • Page: 2 of 2 EMERGENCY AND FIRST AID PROCEDURES Eyes: Immediately flush with plenty of water. Call a physician if symptoms occur. Skin: Immediately wipe off material and wash with soap and water. Material can adhere to the skin. If material has adhered to the skin, use an abrasive containing hand cleaner. If material does not come off, buff with a pumice stone. Inhalation: Move victim to fresh air if discomfort develops. Call a physician if symptoms persist. Ingestion: Seek medical attention. Do not induce vomiting unless directed by a physician. If a large quantity was ingest- ed, give 1 to 2 glasses of water to dilute. Never give anything by mouth to an unconscious person. Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General (natural or mechanically induced fresh air movements). Eye Protection: Not required, however, safety glasses should be worn in most industrial settings. Skin Protection: Avoid skin contact. Cloth gloves are suitable for hand protection. Respiratory Protection: None normally required. Where ventilation is inadequate to control vapors, use a NIOSHapproved respirator with organic vapor cartridges. Never enter a confined space without an appropriate air - supplied respirator. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Precautions: Store in a cool, dry area preferably between 40o and 77o F. Keep from freezing. Do not store in direct sunlight. Avoid contact with the eyes or skin. Practice good hygiene; i.e. always wash thoroughly after handling and before eating or smoking. For industrial use only. Keep out of reach of children. Follow label /use instructions. Spill Procedures: Immediately wipe away spilled material before it hardens. Place in a container for proper disposal in accor- dance with all applicable local, state, or federal requirements. t ; REGULATORY INFORMATION Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE B DOT Shipping Name: Not regulated. IATA / ICAO Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory. SARA Title 111, Section 313: This product contains < 3% ethylene glycol (CAS 107 -21 -1) and < 15% zinc borate (re: zinc compounds) which are subject to reporting under Section 313 of SARA Title 111(40 CFR Part 372). EPA Waste Code(s): Not regulated by EPA as a hazardous waste. Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service: 1 800 879 8000 Health / Safety: 1 800 879 6000 Jerry Metcalf (x6704) Emergency # (Chem - Trec): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) m The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. CO cn n 0 Saving Lives through innovation & education I Hilti Firestop Guide 2005 - 2006 1 1- 800 - 879 -8000 I www.us.hilti.com 455 • Certificate nt Comm liance Certificate Number 20060214- R13240E Page 1 of 1 Report Reference 2006 February 14 Issue Date 2006 February 14 Underwriters YL Laboratories Issued to: Hilti, Inc. 5400 S 122ND East Ave Tulsa, OK 74146 USA This is to certify that Fill, Void or Cavity Materials representative samples of FS -ONE Have been investigated by Underwriters Laboratories Inc.® in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: ANSI/UL 1479, ANSI/UL 2079, CAN/ULC- S115 -05 Additional Information: FS -ONE Sealant for use in Joint Systems and FS -ONE for use in Through - Penetration Firestop Systems as currently described in the UL Fire Resistance Directory. Only those products bearing the UL Classification Mark should be considered as being covered by UL's Classification and Follow -Up Service. y The UL Classification Mark includes: UL in a circle symbol: ^l� with the word "CLASSIFIED" (as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL's evaluation of the product; and, the product category name (product identity) as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product Issued by: Reviewed by: ` na Coulo� Christopher �l n "1 ratories Inc. Underwriters Laboratories Inc. Underwriters L.. Thermafiber "' , W • NONCOMBUSTIBLE ECONOMICAL 'VERSATILE APPLICATION VARIETY OF USES NONASBESTOS For efficient insulation offering condensation control, acoustical correction and thermal values Variety of Forms, Versatile Uses Packing Wool Thermafiber Bulk Wool offers a choice of granulated wool, Similar to Thermafiber Granulated Wool, but designed for packing wool, spray wool, cryogenic and high - performance hand packing rather than pouring or mixing. Recommended (HP) wool. for heat control in boilers, tanks, expansion joints and ovens where the shape of the insulation cavity precludes the use of Granulated Wool felt insulation. Thermafiber Granulated Wool consists of mineral fibers Industrial Spray Wool formed into small nodules or pellets. Fibers are air - cleaned and treated with dust - collecting oil. Can be used for hand- A high - quality mineral fiber insulation, Thermafiber Spray poured applications or mixed with other materials as a filler Wool is lightly treated with mineral oil and produced in pellet in insulating cements and foundry molds. form for pneumatic spray application. Adhesives or binders, added by the applicator, prepare this product for spray Industrial Blowing Wool application. Used for fire resistance, condensation control, acoustical correction and thermal insulation when mixed Thermafiber Granulated Wool is also available for pneumatic with binder. Color uniformity cannot be maintained due to application. variables in raw materials and types of adhesives used. Organic treatment content is less than 1% by weight. Fiber melt point exceeds 2000 °F per ASTM C24. Cryogenic Wool Granulated mineral fiber formulated specifically with an oil content (L01) of less than 0.2% by weight. Used for thermal insulation for cryogenic tanks such as liquid oxygen. High - Performance (HP) Wool Dark fiber formed in nodules for hot surface temperatures up to 1900 °F. Improved performance: less shrinkage and better thermal conductivity for cements, foundry molds and 1111 better and fireplace chimney applications. Nonadsorbent, Corrosion- Resistant Adsorbs less than 2% moisture. Does not corrode steel or aluminum as tested per Federal Specification HH -1 -5588. Easily Applied Thermafiber Industrial Bulk Wool applies easily by hand or with fast pneumatic application. Fits quickly into grooves, slots and other awkward or hard -to -reach openings. Thermafiher witiomiliosioilimmiHt:vc...,,,,.;',-, ,,, NONCOfriBUSTIBLE ECON9L11Ckl VERSATILE APPLICATION VARIETY OF USES 90NASBESTOS Physical Properties Physical Data Installed K- factor--btu • in./hr. eq. • 11. •P" Recommended max. Product density temp. one side - °F 30-ib. Avg. wt. Avg. wt. designation pdp 75•F 300'F 000•F (enclosed panel) bag -cu. 0. Ib.rea1. lb./bele Industrial Bulk Wool (Density varies with packing pressure-three random densities shown.) Granulated 1 { 4.0 .27 .44 .71 800 30 650-750 Packing 8.0 .26 .38 .56 1,200 2.8 30 650 -750 Industrial Spray 1 f 4.0 27 NA NA NA 2.8 30"' 650 -750 Wool l 8.0 .26 Cryogenic Wool .27 NA NA 1,600 NA 30 NA High Performance 700•F 1000•F (HP) Wool 14.0 NA .69 .98 1,900 2.8 30 650 -750 NA-net applicable. Pace* wools for Iwld packing, grounded wool for pourl% spry wool for moans appil don. (1) Bowie of typical fad- hshled densities. (2) Indicates mean Umperadas. (3) Tacoma PWt has only 38 lit. by wrath wool. Surface Buming Characteristics Sound Data - -Noise Reduction Coetlicient (NRC)* Band Center Fregesncy (Hz) Flame spread 0, smoke developed 5 per ASTM E84 as tested - Product Thickness 250 500 100 2000 NRC by Underwriters Laboratories Inc. (UL). Noncombustible as Industrial 2" .66 .85 03 87 .80 defined by NFPA and National Fire Code when tested per S pray Wool y 4 .79 80 .83 .84 .81 ASTM Et 36. 'The addition of any other materials. other than rnfRua BER Spray Wool. and then affect on performance being uncontrolled by Thermabber. are not warranted by Thermadber. Specification Compliance Availability Thermafiber Industrial Blowing Wool meets ASTM C764. - Thermafiber 10 Granulated Wool meets U.S. Coast Guard Wabash, IN Tacoma, WA Spring Hope, NC Nolanville, TX Specification 164.009/169/0. Granulated x - x - x x P10 Granulated x Packing x x x Spray x x x High Performance x Cryogenic x x The iiformati n presented herein For further intonation on nose and other in accordance with our current primed insWo- such as liquid oxygen onka, use Cryogenic represents typical or average values products, including nonstandard sizes, dons. Our Debility shall be expressly limited to Wool only. Cryogenic Wool has a maxi- obtained P vASTM a other standard contact Thermafiber at these sales offices: the replacement of defective goods. My claim mum oN content of 0.2% by weigh. Odra methods. The woes sal vary due b normal Tacoma, WA (180) 421.8127 with respect to an Aged deficiency with the wool products may have greater 011 con - mmrufacpeitg variations. The person using Wabash, IN (888) 834.2371 product contained herein shall be deemed tads, which can create an explosion haz- eds prudud must determine as aulerb8Ay for Nalamllle. TX (800) 762 -9665 waived unless made In writing to as within and when exposed to cryogenic sub - a padadar application. 1pdiig Hope, NC (100) 334-0394 thirty (30) days of the dole such alleged dell- stances. Because conditions of application clency was or reasonably should have been and use are beyond its control, SAFETY RRIT1 Follow good safety and NOTICE: In no event shall we be liable for discovered. Thermatiber MN not assume responsloilfy industrial hygiene practices drxn0 any special, Indirect, indde ntal or copse- for any fire or explosion hazard. handing and installing of all products and quertw damages including. but not limited systems. Take necessary preaulions and to. loss of anticipated profits or revenues. wear the appropriate personal protective whether or not such damages are claimed in equipment as needed. Read material contract. ton (including negligence). warren - safety data sheets and related literature on ty, strict fabilily or otherwise. In addition. products before specification andlor we shah not be Roble for any loss whatsoev- _ installation. er caused by application of these goods not CAt1TION: For certain cryogenic applications � AMERICAN tit ROCP WOOL.. naween ifog"W0 L. INSULA � 3711 West Mill Street • Wabash, IN 46992 -8687 • Phone (888) TFIBER1 (834 -2371) Material Safety Data Sheet MSDS No.: 270 Revision No.: 003 Revision Date: 06/18/03 Page: 1 of 2 Product name: Mineral wool Description: Synthetic vitreous fiber Supplier: Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121 Emergency # (Chem - Trec.): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) INGREDIENTS AND EXPOSURE LIMITS Ingredients: CAS Number: P EL: TLV: STEL: Slag wool fiber 65997 -17 -3 NE 1 fiber / cc NE Phenolic resin 09003 -35 -4 NE NE NE Polyvinyl alcohol 09002 -89 -5 NE NE NE Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. STEL = Short Term Exposure Limit. NE = None Established. NA = Not Applicable. PHYSICAL DATA Appearance: 2' x 4' x 4" sheets. Odor: Negligible. Boiling Point Not applicable. Vapor Pressure: Not applicable. Melting Point: Approx. 2400° F VOC Content: Not applicable. Evaporation Rate: Not applicable. Solubility in Water: Insoluble. pH: Not applicable. Specific Gravity: Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Not applicable. Flammable Limits: Not applicable. Extinguishing Media: As appropriate for surrounding fire; material does not burn. ` Special Fire Fighting Procedures: Soak cartons to help prevent the spread of fire. Use a self- contained breathing apparatus when fighting fires involving chemicals. Unusual Fire and Explosion Hazards: None known. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. Incompatibility: Strong acids. Hazardous Decomposition Products: Thermal decomposition products can be formed at temperatures exceeding 2000° F. Thermal decomposition can yield CO and CO Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: Acute: Eye, skin and respiratory irritation. Chronic: Respiratory impairment. Routes of Exposure: Inhalation, Dermal. Signs and Symptoms of Exposure: Eyes: Mechanical irritation. Skin: Itching, irritation. Inhalation: Nose, throat and upper respiratory tract irritation. Carcinogenicity: Slag wool has been classified by the IARC as Group 3 — Unclassifiable as to Carcinogenicity in Humans. Medical Conditions Eye, skin, and respiratory conditions. Aggravated by Exposure: CD r=- 480 I • Saving Lives through innovation & education 1 Hilti Firestop Guide 2005 - 2006 1 1- 800 - 879 -8000 I www.us.hilti.com 1■■11`TI 7idiCt l�g, g y ,, rii=e MSDS No.: 270 Revision No.: 003 Revision Date: 06/18/03 Page: 2 of 2 EMERGENCY AND FIRST AID PROCEDURES Eyes: Flush with plenty of water while holding eyelids apart. Avoid rubbing the eyes as mechanical abrasions can occur. Call a physician if symptoms persist. Skin: Wash with soap and water. Launder clothing before reuse. Inhalation: Move to fresh air. Ingestion: No ill effects expected. - Other: Referral to a physician is recommended if there is any question about the seriousness of the injury /exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General (natural or mechanically induced fresh air movements), Eye Protection: Safety goggles recommended to prevent particulates from irritating the eyes. Skin Protection: Cloth gloves and long sleeves to protect skin from irritating fibers. Respiratory Protection: Use local exhaust and /or a NIOSH- approved dust respirator when air movement is inadequate to control dusts / fibers below recommended exposure levels. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Precautions: Avoid generating dusts. Local exhaust may be required to control dusts if power tools are used for cutting / trimming. Wear appropriate personal protective equipment. Store away from moisture; keep dry. Spill Procedures: Not applicable. REGULATORY INFORMATION Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE B (Gloves, Goggles) DOT Shipping Name: Not regulated. IATA / ICAO Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory. SARA Title III, Section 313: This product does not contain any toxic chemicals which are subject to reporting under Section 313 of SARA Title 111 (40 CFR Part 372). EPA Waste Code(s): Not regulated by EPA as a hazardous waste. Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service: 1 800 879 8000 Health / Safety: 1 800 879 6000 Jerry Metcalf (x6704) Emergency # (Chem - Trec): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. Saving Lives through innovation & education 1 Hilti Firestop Guide 2005 -2006 1 1- 800 - 879 -8000 I www.us.hilti.com NI`T1 ° 481 A M/'LStar° Anvil Steel Pipe Nipples - Submittal Sheet ( )' � NVIL Anvil Steel Pipe Nipples €-.)/ APPROVED AnvilStarTM offers a variety of Steel Pipe Nipples for the fire protection industry. Anvil's Steel Pipe Nipples are manufactured in accordance with ASTM Standard Specification —_ A733- Welded and seamless carbon steel and stainless carbon steel and stainless steel pipe nipples. Materials include black and hot - di pped galvanized finishes. Anvil® manufac- tures a wide range of stock pipe nipples in 1 /e" diameter through 8" diameter close through 72" inch length in half -inch increments. Wfe also offer standard nipple packs ranging from one each (close to 6 ") and standard six packs which offer multiple counts of each. Cartons are packed with handles for easy carrying. )1k s. a , PROJECT INFORMATION: APPROVAL STAMP: Project: undefined Date: undefined I Phone: undefined Architect / Engineer: undefined Contractor: undefined Address: undefined Notes 1: undefined Notes 2: undefined 3/05 - 104 For the latest UUULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative AnnA Star" Anvil Cast Iron Product - Submittal Sheet " 0 4NVH Anvil Cast Iron Threaded and Flanged Fittings 13® APPROVED A offers the most complete line of Cast Iron and Malleable Iron Threaded Fittings in the industry. Our versatile range of fittings is designed to provide dependable, fire -rated service. Cast Iron Threaded Fittings, are manu- factured in accordance with ASME 816.4. They are UL listed and FM Approved and are available in sizes 1/4" NPS through 12" NPS. li p iii � Project: undefined Date: undefined I Phone: undefined Architect / Engineer: undefined Contractor: undefined Address: undefined Notes 1: undefined Notes 2: undefined 3/05 - 100 For the latest U VULC Listed and FM Approved pressure ratings, versus pipe schedule, go to www.anvilstar.com or contact your local AnvilStar representative • FIG. 92 Beam Clamps /�M/�`LSta1•'° Are Products Division of Anvil Intemational Z /ANVIL Universal C -type Clamp (Standard Throat) Submittal Sheet SIZE RANGE: 3 /e and 1" MATERIAL: Ductile iron, hardened steel cup point set screw and locknut. FINISH: Plain or Galvanized SERVICE: Recommended for use under roof installations with bar joist type construction, or for attachment to the top or bottom flange of structural shapes where the vertical hanger rod is required to be offset from the edge of the flange and where the thickness of joist or flange does not exceed 3/4". APPROVALS: Complies with Federal Specification A 1 92A (Type 19 & 23), WW 71 (Type 23) and MSS - - (Type 19 & 23). UL, ULC Listed and FM Approved. HOW TO SIZE: Size of clamp is determined by size of rod to be used. INSTALLATION: Follow recommended set screw torque values per MSS - - (See table on page PF- 212) \/ FEATURES: • They may be attached to horizontal flanges of structural members in either the top beam or 100 bottom beam positions. = ' 1; 1 • Secured in place by a cup-pointed Set Screw tightened against the flange. A Jam Nut is provided for tightening the Set Screw against the Body Casting. • Thru tapping of the body casting permits extended adjustment of the threaded rod. N • Can be used with Fig 89X retaining clip for seismic applications. E AT LEAST ONE F G I_ FULLTHREAD 1 OF ROD MUST I BE EXPOSED ,. BODY CASTING Ille JAM - NUT SET SCREW FIG. 92 Rod Size Set Screw Max Loads • A Size Top Bottom Weight C D E F G H 3 /8 3 /e 500 250 0.34 lsA6 1 9 16 13A6 3 � lf1 1� 1� 950 760 0.63 1 11 1/2 11A& 1 A 6 2 • Maximum temperature of 450° F PROJECT INFORMATION: APPROVAL STAMP: Project: Date: I Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Refer to the Pipe Hanger Catalog for Additional Parts available on Anvil's Web Site www.anvilintl.com Anvil® Pipe Hangers & Supports For the latest UUULC Listed and FM Approved pressure ratings, versus pipe schedule, (Mr) REV. 03.03.06-009 go to www.anvilstar.com or contact your local AnvilStar representative /ham A AWL-Star" Starr FIG V V Pipe e R I n g S Fire Products Division of Anvil' International Adjustable Swivel Ring, Tapped Per NFPA Standard Submittal Sheet SIZE RANGE: 1 /2" through 8" MATERIAL Carbon steel FINISH: Galvanized SERVICE: Recommended for suspension of non - insulated stationary pipe line. MAXIMUM TEMPERATURE: 650° F APPROVALS: Complies with Federal Specification A- A -1192A (Type 10), WW -H -171 -E (Type 10) and MSS-SP -69 (Type 10). UL Listed and FM Approved (Sizes 3 /a" - 8 "). FEATURES: • Threads are countersunk so that they cannot become burred or damaged. • Knurled swivel nut provides vertical adjustment after piping is in place. • Captured swivel nut in the 1 /2" through 3" sizes. taw Pipe Size Max Load Weight Rod Size A :Ai C F a 1 0.10 2 1 \ F C B 3 /4 0. 10 2 1 1 1 0.10 2 1 1 300 1 0.10 2 1 1 /8 + 11/2 0.10 3 /8 2 1 2 0.11 3 2 1 _ 2 0.20 4 2 1 525 3 0.20 3 2 1 4 650 0.30 411A 313A 1 5 0.54 5 4 6 1,000 0.65 1/2 611A6 5 2 8 1.00 8 7 2 Project: Date: I Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Refer to the Pipe Hanger Catalog for Additional Parts available on Anvil's Web Site www.anvilintl.com Anvil Pipe Hangers & Supports For the latest UUULC Listed and FM Approved pressure ratings, versus pipe schedule, = 0AMV.1L REV. 03.03.06-002 go to www.anvilstar.com or contact your local AnvilStar representative . HANGER RODS ZiANVII.: Fig. 146 Continuous Threaded Rod Size Range: 1 /4" through 11/2" Stocked in six, ten, and twelve foot lengths. Other even foot lengths can be furnished to order. Material: Carbon steel; rod threaded complete length. Finish: ❑ Plain or ❑ Galvanized. Maximum Temperature: 650° E Ordering: Specify rod diameter and length, figure number, name and finish. Fig. 146: Loads (Ibs) • Weights (Ibs) Dimensions (in) Rod Threads Max Load Weight Size A per Inch 650° F per Ft. ��r111 1 /4 20 240 0.12 Length I 3 /8 16 730 0.30 1 /2 13 1,350 0.53 5 /8 11 2,160 0.84 A 3 /4 10 3,230 1.20 7 /8 9 4,480 1.70 1 8 5,900 2.30 1 7 9,500 3.60 1 6 13,800 5.10 Note: Other rod sizes available upon request. Class 2 fit is available upon request. Pipe Hanger Submittal Sheet Project: Architect / Engineer: Approval Stamp: Date: Phone: Contractor: Address: Notes 1: Notes 2: ; r , Schedule - 1O®/Schedu l e -40® 6 3 When you specify Allied Schedule -10 /Schedule -40 sprinkler pipe you get a UL listed anti FM 3r;1_ Although these products do not require separate approvals, Schedule -10 /Schedule -40 gives W <. assurance you demand. Our Sch -10 (1 " - 8 ") pipe and Sch -40 (1"- 2Y2 ") pipe have passed thr >di' testing as our other listed pipe products, and receive periodic mill inspections from both UL tro 1 ensure consistent quality. C) Galvanized Pipe Sch -40 Specifications , ,„: ' Schedule -10 /Schedule -40 product can be "hot -dip" NPS Nominal I.D. Wt. Wt. (H20 Filled) galvanized to meet FM requirements for dry systems Eni m 1, 1 l.bs/Ft; k• m Lbs/Ft; k. /m ., L - in accordance with the zinc coating specifications of 1" 1.049 1.680 2.05 ASTM A -123. 25 26.6 2.5 3.05 -_- - 1 1.380 2.270 2.93 O Superior Coating 32 35.1 4.36 4.36 _ - Our advanced formula mill coating offers a dean, 11/2" 1.610 2.720 3.61 durable surface. It is also paint -ready for custom 40 _______ 4.0 5.37 color applications without special preparation. 2," 2.067 3.650 5.13 50 52.5 5.4 7.63 The internal surface of all Allied Tube & Conduit Fire - -- _ - - ._ 2 /2' 2.469 5.790 7.86 Sprinkler pipe products up to 4.500" in diameter is 65 62.7 8.6 11.73 coated with our new Antibacterial Formula, "ABFII ". In scientific laboratory tests, ABFII proved to have Sch -10 Specifications superior resistance to microbial colonization of pipe NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR walls, thereby inhibiting or possibly preventing the In; runt In;;tmgr tbslft; kg/m tbs1Ft♦ kg /m - onset of Microbiologically Influenced Corrosion 11/4" 1.442 1.810 2.525 7.0055 (MIC) upon installation and the first 25 flushes of 32 36.6 2.7 3.75 the fire sprinkler system.* 11/2" 1.682 2.080 3.04 5 6570 40 42.7 3.1 4.52 j ® American Made 2" 2.157 2.640 4.22 4.5327 Meets "Buy American" requirement and is available 50 54.8 3.9 6.28 1 - through distributors in the USA, Canada, Mexico 21/2" 2.635 3.530 5.89 3.5196 ! and Latin America. 65 66.9 5.3 8.77 - 3" 3.260 4.330 7.94 2.5550 ® Specifications & Approvals 80 82.8 6.4 11.82 - Schedule-10/Schedule-40 pipe are in compliance 4" 4.260 5.610 11.78 1.6020 with the following: ASTM A -135, and NFPA 13. 90 108.2 8.3 17.53 All pipe products have a rated working pressure 5" 5.295 7.77 17.33 1.4874 of 300 psi maximum and also meet the stringent 125 134.5 11.56 25.80 - requirements for the following applications and 6" 6.357 9.290 23.03 1.0251 tests: 150 161.5 - 13.8 34.27 - • Welded Outlets 8" 8.249 16.490 40.15 1.8365 • Hydrostatic Pressure 200 209.5 24.5 59.75 - • Side Wall Rupture ® c CL •PPRRVEU * See ABFII warranty x � pis TC1 & c N1DUEt 16100 51.4th /ap • Harvey, IL '60426 1 11350 Hat n Rd • PhD . r;,"' tea 1 252 N 2 ' . ' ' �f •:' nix, :;5009 S5-3 m emt ' g a 62,, i ,,,,„d- i ,,, 2,..„_,, , _ 13 3 Zephyrhills Fire Re lip if , v R , s s 6907 Dairy Road, Zephyrhills, FL 33542 (� Fire Marshal Bus (813) 780 -0041 Kerry Barnett Fax (813) 780 -0044 E- mail: kbarnett@fire.zephyrhil]s.fl.us Plan Review #: 10 -087 Project: Sprinkler Modification Number of Pages: 1 plus Packet July 26, 2010 I have received and reviewed the plans for the sprinkler modification located at 7850 Gall Blvd and will allow the project to move forward. No permit was required. Contractor allowed to perform work under original permit, however there are fees to be paid due to the revision of plans. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. Inspections Required: 1. Press - - Test (normal operating pressure) ' i t a A Lit 'J' 7h KE RNETT, FIRE MARSHAL ** *Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. ZEPHYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Fire Chief Keith Williams Bus (813)780 -0043 Fax (813)7801-0044 FIRE SERVICE USER FEES Occupancy No.: Plan No.: A (,}p7 Contractor ('/ p..SGC7 Business Name: AZtnx . i C a Billing Address: 'Srl Business Address: 7' - � � . ress: � � Business Phone No.: Billing Phone No.: I dp Business Fax No.: Billing Fax No.: j Contact: Contact: l PLAN REVIEW FEES _ INSPECTION FEES ! — PERMIT FEE I — FALSE ALARM FEE Site Plan N/C _Annual N/C _Sprinkler $50 — 1st Alarm N/C _ Multi - Family /Commercial .06 sf — — (Minimum Charge 1st Re- inspection N/C _ Standpipes $50' — 2nd Alarm N/C 0 Minimum Char a 525.00 _ Fire Pump 2nd Re- inspection $100 — p $501 _ :3rd Alarm N/C Plan Revisions DBL — 3rd Re- inspection 5250 — Hoods $50I _ ;4th Alarm $100 _ 4th Re- Inspection $500 _ .Fire Alarm 550 — 5th Alarm $150 SPRINKLER SYSTEM (Business closed until __ LP Gas 550 _ ,6th Alarm $200 - 25 Heads 0 5 OP violations corrected) Natural Gas _ . $501 _ NON COMPUANOE $150 2 6 plus Heads 100 SPRINKLER SYSTEMS Fuel Tanks- per tank $5 01 STANDPIPE SYSTEM Hydro Undergrounds • _ Sparklers $10 0 Per Riser $50 Hydrostatic Test er system __ Fire Works $Sop FIRE PUMP Acceptance Test '- per system _ Camp Fire $25� fl Per Pump $100 Hydrant Flow $75 Controlled Bum $100 FIRE AI-ARM SYSTEM — Hood/Duct $50 0 - 25 Devices 550 _ ; FIRE ALARM SYSTEM i _ — Place of Assembly $50 I Annual 26 plus Devices $100 — System Acceptance $50 I Fire Protection 5251 SUPPRESSION SYSTEMS _ $50 Recall Acceptance $50 Flammable Application $501 Annual — Wet _ OTHER Waste Tire Storage . 550 Annual Dry $50 _ Fire WaWSmoke W alt $15 l _ per wan _ Generator < KW $10 — CO2 550 _ LP Gas $25 per t Generator >30 KW 150 _ Other $50 _ Natural Gas $25 per s ystem Bio-Hazard Waste 5100 Annual KITCHEN EXHAUST _Fumigation Tenting 550 0 Hood/Ducts 550 _ Tent 10'x10' or greater 515 par tent Torch Pot/Applied 550 OTHER ` _ Fire Pump $45 � _ Haz. Materials $100,' Annual LP Installation per tank 550 — Fire Suppression 530 Fuel Tank installation 550 _ System Acceptance (Per Tank) 550 _ Exhaust Hood/Duct $30 0 Natural Gas Installation $50 _ Re - inspection DBL (Per System) (other than annual) E Spray Booth $50 0 Inspection scheduled DBL _ f and cancelled less than. I 24 hours Construction Insp. N/C ew Emergency Vehicle Ao ` 0 FALSE ALA ALARM PLANS TOTAL Era INSPECTION TOTAL J5 t PERMIT TOTAL I 1 TOTAL GRAND TOTAL I' 9//( I • Comments: /4 1 E 4 1 I I 1 r Aj W; le- .FAII11 - 1. 7 4 7 1-740-"MIMa I Wv / Date: ,' Inspector: y - , P- May 1, 2004 Sprin Iter 105 a NIKING® QUICK RE TONSE TECHNICAL DATA DRY PEN CENT SPRIN I'IERS 1. PRO WCT NAME SPRIN I.ER MA lE RALS Viking Model M Quick Re saonse Dry Pen- Frame: Brass Cast ngs UNS- C84400 dent Sprin Ners De fec br: Brass UNS- C26000 • Ad pst thle Re essed, Ad fist 93le Stan- Bulb: Glass, nom ire! 3 mm di an ear dard, or Plain Bar el Belleville Spring Sealing As sem tiy: Nickel Avail tie since 1993. Al by, coated on both sides with Tefbn 2. MANUFACTURER Tape The Vi kng Corporation Spring Base: Brass UNS- C31400 or 210 N. In dts tial Park Road UNS-C31600 Hastings, Mich igan 49058, USA Screw: Brass UNS-C36000 Tele (alone: (269) 945 -9501 Pip Cap: Brass UNS-C31600 (877) 384 -5464 Seat: Cop per UNS-C21000 Fax: (269) 945 -9599 Or ifce: Cop per UNS- C21000 e -mail: techsvcs @vikingcorp.com Washer: Stain bss Steel UNS- S30400 3. TECHNICAL DATA Gas let: Buna - N LIST NGS AND AP R2OVALS Tube: ERW Hy dau lc Steel Tube Re er to the chart be bw. In et: Brass UNS-C31600 Plain Ap Roved to a max inum length of 48" Sup pi (In br n31): Stain bss Steel Ad Pst ble Bar el (1 219 mm)'. UNS- S30400 Re Eossed ' Lengths over 48" (1 219 mm) are avail tole, with no Spring (In �r ral): Stain bss Steel Ad first ale ap pov as, on a "made -to- order" basis: UNS- S30200 Stan card • Recessed Dry Pen cent up to 65-1/2" (1 664 mm) Bar el: Steel Pipe UNS- G10260, Elec to- •Ad jest d,le Standard Dry Pen cent up to 63 -1/2" de IDs t el Ep ocy Base fin sh AC tFS ARIES (1 613 mm) Sleeve (for Ad fist dale Stan card style Dry Sprin Iter Wrenches: • Plain Barrel Dry Pen cent up to 65" (1 651 mm) A. Stan card: Part No. 07297W/B Contact the man ut�c trrer for more in br rra ton. only): Brass UNS 026000 o B. Re assed: Part No. 07565W /Bt Glass -bulb fluid tem ler atrre rated to -65 ° F UNS - 026800 ES GJTCH ®N MA E RALS 1-Requires Vi k a sep aete' / :" ratchet (not avail ale ( -55 °C . g) Rated to 175 psi (1 207 kPa wa !'r work hg 1 . Ad first tile Stan Bard Dry Es cutch Eons: from vi kn P ( ) Brass UNS-C26000 or UNS-C26800 Re Mace went Es cutch ems: pres sire. 1. Ad fist ails Stan card Dry Es cutch Eon Thread Size: 1" NPT 2. Re assed Dry Es cutch Eons: Cold Base Part Num ter 07741 Nominal K- Factor: 5.6 U.S. (8,1 met re') Rolled Steel UNS-G10080 2. Re assed Dry Es cutch Eon Base Part AVAIL ABLE FIN SHES ap Roved lengths. essure is • R e assed: Chrome- Enloy® (pat sits Num ter IN for all listed and a ro "Metric K- Factor shown is for use when pressure O BRING IN FOR NA TON measured in kPa. When pressure is mea sired in pend ng) or White Poly ES br For er ro ship spec BAR, multiply the met is K- Factor shown by 10.0. • Standard Ad p st tie: Chrome -Enlo P P P nent, P fy: model, or - Min. Op a ding Pres sire: 7 psi (48,3 kPa) A face size, fin ail, tem atire rat hg, • Bar el: (sprinkler only) Chrome- cutch Eon type, and length ( "A" di nen Son). Fac bry tested pneumatically at 100 psi Enloye or Brass (685 kPa). The "A" di nen son is the cis 13 nce from the Spring: U.S.A. Pat eft No. 4,167,974 SPRIN H.ERTEM FER AlURERAT NGS face of the fit tng (tee) to the de Bred fin - Re frr to Ta tie 1 on page DRY1 for dry ished ceil ng to a ton (see Fig Lies 1 Bulb: U.S.A. Pat art No. 4,796,710 sprin Iter tem pr are rat ngs and max. through 3). am b eft ceil ng tem pr atires al bwed. Ap p'oval Chart Temperature KEY Quick Response Finish Dry Pen cent Sprin Ners A l X f Escutcheon (if applicable) Thread Size Sprinkler Description Nominal K Factor° I Order Length 3 Increment Listings r NPT f BSP , Sprinkler Style Base Part Number''. SIN U.S. 1 metric , Inches mm cULus NYC 1' i — Adjustable Standard 08383 i VK176 5.6 8,1 '/4' 12,7 Al Al VK180 6 1 � `Adjustable a Barrel 08387 VK1 Recessed 72 5.6 8, 1 _ 1 /4" 6,35 B2 62 72 5.6 8,1 L ' / z 12,7 A3 j_ A3 Ap proved Tem per afire Ratings Avail tile Ap proved Finshes A - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141 °C) 1 - Chrome- Enloy® B - 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) 2 - Chrome- Enloy® or White Polyester 3 - Chrome- Enloy® or Brass 1 2 Base part num ter is shown. For com Pete part num ter, re br to Vi kng's cur ent price sched tie. This to Ile shows the list ngs and ap pov as avail sle at the time of print ng. Other ap povals may be in pro ass. Check with the man u fac firer for any ad d tonal approvals. 3 Min inum length ( "A" Di nen son) = 1 -1/2" (38,1 mm) for Sprin Her Base Part Num ter 08383 and 3" (76,2 mm) for Sprin Iter Base Part Num- bers 08385 and 08387. Max inum stan Bard (listed) length for Quick Re ponse Dry Pen ent Sprin hers ( "A" Di nen son) = 48" (1219 mm). 4 K- Factor ap Hies for all lengths in dated in Foot rote 3. Met is K- Factor shown is for use when pres are is mea sired in kPa. When pres- s sure is mea sired in BAR, mul t lay the met is K- Factor shown by 10.0. 6 Ac epted for use, City of New York De part rent of Build ngs, MEA Num ter 89 -92 -E, Vol. 15. Listed by Un cpr witers Lab oe bries Inc. for use in the U.S. and Can aia. Note: Units ofmea sire in pa en he s may be ap pox inn tons. Re Paces page 105 a -b, dated Jan uay 16, 2004 (updated drawings). Re br Form No. F_031793 to tech ri al data page DRY1 -2 for gen eal care, in Sal h ton, and main - te rance in br rra ton. Sprin Her 105 b May 1, 2004 QUICK RE TONSE NIKING® TECHNICAL DATA DRY PEN CENT SPRIN I.ERS The dry pen dent sprin Her must be or cared cessed style, in 'W (12,7 mm) in me nnnts 4. ESCUTCHEON IN &AL IA11ON and manufactured spe cif irally for one of in lengths from 1 -1/2" to 48" (38,1 mm to 1 In gall the sprin Ner onto the pip hg three styles of in Sal A ton: with the ad pst- 219 mm) for the ad pst thle stan card style, prior to in gal! hg the es watch ®n (re br able re classed es watch Eon (see Fig ue 2), and in /2' (12,7 mm) in cre rents in lengths to page DRY1 -2 for in truc tons). with the ad pst tole stan card es awtch clan from 3" to 48" (76,2 mm to 1 219 mm) for The es witch Eons slip on from be bw the (see Fig ire 3), or with the plain bar el (see the plain bar el style *. ceil ng to al bw installation of the sprin Her Fig ue 1), in Sailed with no escutcheon. The re classed style es catch en, with up to prior to ceil ng con Sruc ton. The sprin tiers are avail tie in 1/4" (6,35 5/8" (15,8 mm) ad pst nent, pro ides an aes- mm) in ee rents in lengths from 3 -1/4" to thet irally pleas ng re essed ap ear ance. 48" (82,5 mm to 1 219 mm) for the re- • 1111111 11.6 j Il ���l Il�I ■ � � ���� a � ' „, .,■■ ,, .. For "A" Di Wen son: �'= ;__ = , For "A" � - ='i 1. De br rune the dis once from I j- Dimension: - ° -1 -- face of tee to fin shed cell- 1. Determine i ing• Outside A the distance I A 2. Round to near Est 1/4" (6,35 from face of tee mm) be tveen 3- 1/4 " and 48" diameter: to base of Min inum ceil hg hole size: (82,5 mm and 1 219 mm). 1- 5/16" sprinkler. 2 -1/8" (54 mm) di an ebr. NOTE: Sprin tier will be re- (33,4 mm) 2. Round up to Max imam ceil hg opening cessed ap Rox irately 5/16" [same as the next higher size: 2 -1/2" (63,5 mm) di an ebr. (7,9 mm) above fin shed 1" (25 mm) '/_" (12,7 mm) Adjustment: - ceil ng with 5/8" (15,8 mm) schedule increment vertel ad pst nent avail - Pi 5/16" 40 i �� between 3" (7 mm) c == 1__ . able. (76,2 mm) and 5/16" (7,9 mm) - ' - ' ', 1 1 -5/8" 48 "(1219nm). c == - - - - Fin shed Ceil ng II. (48, +mm) Min inum: 1" (25,4 mm)- __ II• Max inum: 1 -5/8" (41,2 3-1/16" Fig u'e 1 (77,8 mm) Plain Bar el Dry Pen cent Sprin Her Fig (re 2: Ad jest Sale Re classed Dry Pen went Sprin Iter (up to 5/8" (15,8 mm) of Ad jistment). For "A" Di nen son: 1. De er nine dis dnce from face of tee to fin shed ceil rig. 2. Round to near Est ' /2' (12,7 mm) be tveen 1 -1/2" and 48" (38,1 mm and 1 219 mm). NOTE: To lo rate the de fec- 4 MIII li= tor at the min iTrum dis g = =e tance be bw ceil hg, with 1 no up card ad pst 'rent NOTE: The de fec br will be avail tle, or cer the ad pst- located ap pox irately 3- 7/16" Min irrum ceil ng 7/16" able stan card dry pen cent (87,3 mm) be bw the ceil ng A 1 opening diameter: (61,9 mm) sprin Her 1" (25,4 mm) with 1" (25,4 mm) of up card 1 -3/4" (44,45 mm). min. shorter than the "A" di nen- and 1" (25,4 mm) down- Max inom ceil ng 11 [ sion. ward ad pst nent avail tie. 1 hole di an ebr: De fec br at min inum 2 -1/4" (57 mm). dis once below ceiling 1A[ ®W 13/16" Fin shed Ceil ng � p m „ - (20,6 mm) NOTE: To mlo ax inum dis g rate the de nce Mir tor at mance be bw ceil ng, with no 1-1/2" (38,1 mm down ward ad pst Went ( ) - Sleeve fin sh 4- 7/16" avail thle, or aerthe ad pst- di an eel* I, matches es watch ®n (1 maz m) able stan lord dry pen cent sprin tier 1" (25,4 mm) Ion - 3- 1/16" .1I. ger than the "A" di nen- (77,8 mm) II ♦ sion. De fec br at max irrum dis once be bw ceil ng Fig ire 3: Adjustable Stan dud Dry Pen cent Sprin Iter (up to 2" (51 mm) of ad pst Trent). Re paces page 105 a -b, dated Jan uay 16, 2004 (updated drawings). Re tar to tech ti all Form No. F 031793 data page DRY1 -2 for gen eaI care, in dal h ton, and main b rance in br rra ton. - , . } } l I I } � � C 1 4 f I t f 9 1 I • I, I JAd I( i r a __,-..._ .,.__,..._._.....__.:.,,._..a.: .... ........._,..,,.w- _. «_........� ..:,..,..__._....._......._.., _..•,,. ._.. _.._... _ .,.. .....,....- .,_.__.._._...a._ ... .._......._.__.._ 1 •� ^..w ^,,• .-T' , � _,1, --. „fr rc> ;. >, j ': ,••• ... t..,.... ...., .. ,. I +...� _-,._ . _.... O .- _ __. • -__ _._....._. . _ __.. _ -... ___ - 4 -- _. _. - ! �r 'M f: _ ' `. •�1 r .,.rJ i ♦ � 1t ♦ i 1 � 47�- `� ,•su' a.,_ �_ I I C III-: FLOOR PL)V4 ` I {� T, . w y� s I I _ A _ , .ueWaYa551 eWY... . •a:atsw:Y1/ S „,... .... u_uWii.Y+r Wv ta•.iJJ ...e ^ i,1..s:s Wus. cab'! awvsu....a, 1 '� 'k. ...�. �' I r � A I - I f I f ; t t 1 r • '� . ���y 4 aL,Xwe w ,awFa.+- b4,cr.�.•'+b Saa+dowr Fi I w _ _._ Gull 0 � TO BE � ; � �- �f , 1 ublix DESICN50, PERMITTED, ! ' =�- � A"�D t:ONSTt�UCf Eta r�5 � •- _. -�_�.x , I�f _ I ErE Ir SAFETY H .�- A142 4, R f`2 TO SHE T � j r _ _ r %� FOR t,Ur��p_1 3 -� tF IRE YD 7AN't � A SEPARATE SEr car f � �� � � � _,.. !NF�i�Ms�'TIt�N FOR BUILDING C r OfIAWINGS , � � OA }... _ �_.._� _.__.. „._.___.__ __ _. ____ it • _ I I �I ' Ti 'il UIl.1 11It3 TO Bit !L!? . �' ° ICES IUIFD E =Rh11 r f0 a ! B IC, A CONS E IZl� 1 G.t� AS C Bld 11. d LWAR:+�YJf*.uy^' I 1 ll OF L)IMWINGS TENS BUILDING TO BE PHIS BUILD :N +TO SE DESE "NED, PE]WITTED, ! THIS BUILDING TO ICE C ESICN :D, DESIGNED, PERMITTED. NEW TENANT SPACE � AND CONSI`RUCTE0 AS e PERM AND CONSTRUC AS I � r � A��IQ t�t;�`�;�TIiL3CTIx0 AS MR BLOCK (Q5/D6� A SEPAI�A i SET A SEPAEtA °TE SE I” OF DRAVr NC a A , ,5EPARi TE SET x Or DRAWI T W O 0tA I"rl ,.... __...T , ,.W....:_,...J� •..,.7"" LY` ".' 'C..7'_' ��Y_�� _"'� "'�" '� t "' _'°'. "_' A y ..`.._ i_T.. • ' . 't�,...�I - T �... R .� � - 1. � - _ . __ _ .. _ _. .,_ _ .__ _ _.- •__ .__ .__.. , � a~ �, % "{/'' �.-_ �_. s.__>, s- .a���se........,�tm. rasa :.,wa.c.s.a,.,s.�..,�,.,xvs, art, v. �.. ffi..,. Jh° �... t_a�...._• >1...�..cu;,c.....Ls� �.. L sli •^_ .:,'t,'a+*a_xrw- •- e:.msw+< sir$ a.- a�Ynm�- °sa��:vwaaa :- a-•»�+ _.'S .r,::..., x.,,�_._. �...__.- ...... ....__...., .__..._„_ _....______.__...._.._ ' n az ".._` ®�aa.a_+b w a .au•ubr swm,:aia c:utl•vaa naww.W 'gyr O[" .wa1 � tiy�.ac�vmsM "..er+mM�.0 . �[e,a�..Y."�►s�.iewuerstiui�a -:• sa{ �- x s ,z�.uwws a •m:.w eusu..: _ r;au; berme.' ,.f.-�exew ��cmuuaryaY.w3'^•R ,.. a'vwwiwaraaaemma aa&axc'x YarX xt,n1 Cs aeY9pY, 'a ^ »aao+s. .a4s.ux xcu,'aa„rrim.:�z- waWeY�.a.�a w�s9aua::. uR. ..s.+r�Li 15 ' wr yi � _....:,.� .. ..,,..,.,:,..'�.•..:,..,...�.., , ........_..,.:...........=, .,v:„..w..� «..,.........,_.«,.. ....,..... .,.... ..,.... _.......... ._,. _,v,.,. ..,_.,_ .....,_.,.._��__'° - - z�, y...__.�._. W .....a.. ae� >,1..._,..,_ _�.....,.....� _„a.. >,w, . ., _ _ .,.- ........._ .,,..._. ....._J..,........ .._... «...,. ,.,,..._. .....: «..:....,_.; °ORmuc'A+areoe 'aa'a�°rmaz�oo' - .... _:;vz�'. •- �sv= �.zae{ ��,':.:,s.a7�'.�:._.:�� -' -_; ►WTa!irP. 1A!��,� ¢� �y � - ,•.�•• � ��,• '•,•- ` "da __. yf�as.. �wv' a�z iR. c�ulawNis. odli��i a++ hsa�3 xanfdAy.' sa';. g�6wac:. u `lYts�.brerk^.:at:r♦�asaSmm� y^�°' = 13�rDJ hLY M ' 4 L[ib+Mi- e•bY39YHQ LJ6.4YtlMIRYAJ�t:l1' 7 iM:�131f1i':WIIWW 19CfpISfiiNd6/3'Sd`'li� ii '`�� '_..,, Ir wxrs � i { :.•✓""" �e�' ( aa.s'a:.s�vm�.sr� ,s .•�c;.n ' a "Y�I��m�,t m�M��a•ara'n�:af�2r:>.W'N� , � Y �J •rg. i �.+ �!,➢ N `adadr AarNh .l.t�� "x4Jde+47..C4.iE�F�6's rYSi4c6'6Y �5: ..�H's5.e.'"�••a:criWaYWiKf51i1� .- c�E'YbWibL , .: .�mv ae•terr,.uep+ MolaraWra?xc.x+exp wuraxs�.r�aa+u 3-- •:... -..r , y ..,� -.•.. _ _..,,.: _ .«.. - _.�»�v -- r. _�F_ _.. _.max '._.�; a+. .... ._ _.... _._, r.. _. _ _ ._..._c_. —. a�._:re:... _ __•.. ' xr- �_._..aax _.�_�sc�s _ _ems �:j a ::ear rr f •. 'a / :'C♦.�i0[PA � i#.tlrwbIIaY: Ndf MNcG4 aa.81a6M4:d&i `2. • Y• � �+, !' � to °�., •• �"' I� ,� __ � � �3?k. • � { �r .. r _.... _ ._._,- ,..._.,... _._.., ,. _.. .- ,...w._..... .-. �.. -,.,. ... . „. Z1 ;� �, ggyg _ .. ,.�.' �.Ek,7' . -df_ \ • •• � '• i � 1/ °' -k 1, ��� , ,.,:,._...._ .-. _ ; __. »..�..._Y..:SX:._._.... ..'T.. -, ?..:- .._i`•'1_�'C2 -sS::k �_ ._�C�.- ..S.S«'1 _..83ry i r: •M,,, 5 t.c- � ► �i t i •, � \ �' 1 _„�o�� ... � � ��, � � '. ` 1 _.�iG2...�::Y.:Yl:�� "`:::: �4r, .i,..G..•• -]' :2::.: .__ •�.Y. , � � r � ^"�"� •. .� � ..t \, I ,F ,. � � I � � / I a l t ✓' r s.M,•. • ^o- ,\�. •�, ICI -•�\ I f ! i �{ i j I 1 • r \ \ / \ \� D ..err ^✓ � "—':x�" ,� `\ , I I `..._. �._,....«. -._ _._,. ._._._...- ._.... -_ •, - ..- ._.— ._. °-_,:.'1._ _.___... ?`��� _.. ..._ _._,_�..._.. _r s 1 � � � I { X,\. TO SPRINKLEM K e, - }'�. .��• S1r+Yi'•aYt.ta:a1WIW.t::vn - .s w� +n. _++arww....�,.v� f'�' y ' sacs.. -LOW SWITCH ` ',sue # ` � }. !"d � ��,� � he �,� �Y �R 7 } �Ep�. � �: wr .:a...+w a a =:ua+w.:_a^n+c a'.as4 z4 `'P'Aq ej� ic" _A� WALL MCUNT F0w STORTZ TYPE. ° PIK DRAIN TO EXTV1 oN SPLASH EL(XK — i NSPECTV3 TEST & DRAM CHECK VAL W1 0RAJN VALVE AND M93 0C T I10L VALVE W/ TAMPE[A SWITCH SUPPLY P IPE." FINISHED FLOOR EXISTIr40 1 NOT TO SCALE EXISTING RISER. SEE DETAIL THIS SHEET. ___\N # I # C#1 0 5 _L J ' DRY DR DR w - a I 2 x 2 mac./ `mac•/ �' I I i j I t I , z a _ v 2 2 — L - ` 3w% jiK q 5 / — ON OVERALL S PLAN NOT i0 SCALE REMOVE EXIS77NG UPRIGHT SPRINKLER. NEW 1" 90 ELL . NEW I" ARMOVER GREA TER (TYPICAL) I I 24" SHALL AVE ANGER. EXIS77NG I* SPRIG `'• - ♦.. EXIS TiNG 2' I I SRANCHLINE ,,,,, -,NEW I" DROP NEW 1 " x 314" R.C. 2x4 ACT CEILING f%..jUARTEwl POINT SWING JOINT DETAI NOT TO SCALE • •�w.ca • ae1" . .l \ 1 I BEAM CLAMP -- ALL THREAD ROD (A.T.R.) 3/8 N A.T.R. 4 AND SMALLER ADJUSTABLE SWIVEL RING OPEN WEB BAR JOIST FOR 1" T1iR000H 4" NM HANG MAINS TO TOP CHORD OF JOIST ONLY BRANCHLINES MAY BE HUNG I L FROM BOTTOM CHORD OF JOIST. OENI NOT JCeMI'_1 lEl: 0LAN�S) lt1 VVE EN Ajz h1iwE* SPRINKLER HEAD LEGEND SPRINKLER SYSTEM SHALL COMPLY WITH THE 2002 EDITION OF NFPA 13. SYM QTY TYPE FINISH TEMP K NPT_ MFG, MODEL SIN DESCRIPTION MM COVERAGE J EX EXIST UPRIGHT BRASS 155 8.00 3/4' Mete comprmce with aA app NFPA codes and EXISTING EXPOSED / 130 SQ.FT. (THROUGHOUT) ALL WORK SHALL BE COORDINATED WITH OTHER TRADES PRIOR TO FABRICATION. 28 PENDENT WHITE 155 8.00 3/4' VIKING M VK-352 RECESSED 1" DROP (E--1 ESCUTCH) / 130 SQ.FT. DRY 3 PENDENT CHROME 155 5,60 1" TYCO DS -1 TY -3235 1" TWO -PIECE DEEP ESCUTCHEON / 130 SQ.FT, 31 = TOTAL QUANTITY FOR THIS TENANT, ALL HEADS ARE QUICK RESPONSE, TO SPRINKLEM K e, - }'�. .��• S1r+Yi'•aYt.ta:a1WIW.t::vn - .s w� +n. _++arww....�,.v� f'�' y ' sacs.. -LOW SWITCH ` ',sue # ` � }. !"d � ��,� � he �,� �Y �R 7 } �Ep�. � �: wr .:a...+w a a =:ua+w.:_a^n+c a'.as4 z4 `'P'Aq ej� ic" _A� WALL MCUNT F0w STORTZ TYPE. ° PIK DRAIN TO EXTV1 oN SPLASH EL(XK — i NSPECTV3 TEST & DRAM CHECK VAL W1 0RAJN VALVE AND M93 0C T I10L VALVE W/ TAMPE[A SWITCH SUPPLY P IPE." FINISHED FLOOR EXISTIr40 1 NOT TO SCALE EXISTING RISER. SEE DETAIL THIS SHEET. ___\N # I # C#1 0 5 _L J ' DRY DR DR w - a I 2 x 2 mac./ `mac•/ �' I I i j I t I , z a _ v 2 2 — L - ` 3w% jiK q 5 / — ON OVERALL S PLAN NOT i0 SCALE REMOVE EXIS77NG UPRIGHT SPRINKLER. NEW 1" 90 ELL . NEW I" ARMOVER GREA TER (TYPICAL) I I 24" SHALL AVE ANGER. EXIS77NG I* SPRIG `'• - ♦.. EXIS TiNG 2' I I SRANCHLINE ,,,,, -,NEW I" DROP NEW 1 " x 314" R.C. 2x4 ACT CEILING f%..jUARTEwl POINT SWING JOINT DETAI NOT TO SCALE • •�w.ca • ae1" . .l \ 1 I BEAM CLAMP -- ALL THREAD ROD (A.T.R.) 3/8 N A.T.R. 4 AND SMALLER ADJUSTABLE SWIVEL RING OPEN WEB BAR JOIST FOR 1" T1iR000H 4" NM HANG MAINS TO TOP CHORD OF JOIST ONLY BRANCHLINES MAY BE HUNG I L FROM BOTTOM CHORD OF JOIST. OENI NOT JCeMI'_1 lEl: 0LAN�S) lt1 VVE EN Ajz h1iwE* 1YLEP1iYRHILLS k1 _ SPRINKLER SYSTEM SHALL COMPLY WITH THE 2002 EDITION OF NFPA 13. 2. SPRINKLER HEADS SHALL BE ORIFICE, STYLE AND TEMPERATURE TO MEET CODE. REFER TO SPRINKLER HEAD LEGEND THIS SHEET. 3. �'Ie�e be al this review of plans submitted Is a SYSTEM TEST SHALL BE WITNESSED BY CITY OF ZEPHYRHILLS FIRE MARSHAL PRIOR revie'd to mist the contractor i Co with TO ANY PORTION BEING CONCEALED. GIVE 48 HOURS NOTICE. kab$e fire safety cotes. Thi review is riot intended to be a final approval of the submitted plans• it is th 4. HANGERS TO BE PER DETAILS ON 'THIS SHEET. HANGERS SHALL BE SPACED IN wrltracws sole responsibility to ensure ih• t tiro Win Oro jr ACCORDANCE WITH 2002 NFPA 13 REQUIREMENTS. Mete comprmce with aA app NFPA codes and local ordinanll In the ewent that further examination or 5. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES PRIOR TO FABRICATION. site inspecCon reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole expense to g♦ bring those areas in compliance. The City assumes no 2" PIPING AND LARGER SHALL BE GROOVED SCHEDULE 10 WITH THREAD —O —LETS OR responsihiltty for the contractor's failure to be in compliance GROOVE —O- -LETS. 1" PIPING SHALE. BE THREADED SCHEDULE 40. 2" GRIDDED PIPING wi al appl'K&e NFt A Code and local ordinances. SHALL BE GROOVED SCHEDULE 10 WITH THREAD —O- -LETS. 7. ALL PENETRATIONS THRU FIRE RATED WALLS SHALL BE PROPERLY SEALED USING UL LISTED METHODS AND APPROVED PRODUCTS TO MAINTAIN RATING OF WALL. N 0,/ W tY � a U 0 m >- ca m m 4 , 0 0 Q C1 Cq W O U C� CP F-- OU N r C4 A N FIRE PROTECTION FLOOR PLAN %M PERMIT 0: 104S CAPSCO JW APPROVAL: M DRAWN BY: M B SCALE: A SHOW DATE: 6/10/1 F-"--1 of 1 I 1 I 1 0 � 4 I Blda A Ala - `--- �. - - -. �-� III i "� RH� I , MYU CIVIL '1 q i LOADING DOCW, FLOOR Pt1tN C} i T r. .. �_.- ........ _......._ ........ _ . _.__ M ...tom ': - -.+ •. � � r� � � .w. �0 PERMITTED, AND CCN$TRUCTEO AS I � � AND (ANSTRUC7Uj A3 A SEPARATE SET OF DRAWINGS A SEPARATE SET OF DRAWINGS -! woo op" OVEF1ALL SITE PLAN .r. �....� w.r...�.w...r+ .,+...... w.++.._ r_ w�.. �isw. d....+ ww+. rr.+.+. ..u.wsr_.r.r��w.�w._...www...wu . r.... w. r....- w.w..+.i�.rnw...wr.r...wwY..wsl �r....w.�w.w'. r..... w. wa. ww .iM4.Y.w.YwY_...•I.ws.Yw.MVn..f ..w...F�.Fw.www.FF ' �W ..� . w . +nwwr.wiw.wn.w'w".w.na_. NOT TO SCALE t TO SPRINKLER $Y$ l� FLOW SWITCH IY" A a ......... A. A 01100VE CHECK VALVE T ..- HALL MOUNT FDC PIPS DRAIN TO ECM ONSPLASHBLOCK 7-11;1 L INSVEcroRs rEsr a aPnN � cHEcxv�uvEwiowun va.ve arro oaoEa -- CONTROL VALVE WJ TAMPER 31MITCH EXISTING RISER. SEE --- \�N J C* DETAIL THIS SHEET. � suraLv PIPE FINISHED FLOOR EXISTING RISER DETAI NOT i0 SCALE GRAPHIC SCALE ' 0 4 8 18 -- -•— 5' - 0" -=- -- 10' -0" --•- -" 10' -O" _�...�._. 10 IN FEET F IRE PROT PLAN S CALE 1/8" -) t� -oM SCALE: 1/8" = 1' -0" THIS BUILD TO BE DESIGNED, PERMITTED, REFER TO SHEET A102 _...._. _ AND CONSTRU AS .$ FOR COMPLETE LIFE WETY A SEPARATE SET OF I INFORMATION FOR BUIL G _ DRAWINGS -wo B E3 I THIS BUILDING TO BE --�- . THIS BUILDING TO BE GESIGNEt3, DESIGNED, PERMTIEED, ase be advised this revie m of plus submitted is a dory review to assist the contfactor in oonVgam with applicable fire safety codes. 17hi.'s review is not intended to be a final approval of the submitted plans. It is the contfacWs sole responsibility to ensure that the plans are in 00rnplete ompgarm with all applicable NFPA codes and local ordinances. In the event that further examination or site kvspectiorn reveals areas of non— wnpli<nce, it shall be the conbachbes sole responsibility, at their so'e expense to bring those areas in cornpisance. The City mu r no responsibility for Ilia oontractor's failure to be in a ' blix with all appt'rcab'e NFPA Codes and Local ordin 0 81M1 7'I EL' PLANS) HA E BEEN RF VIEWEI : A-Y ZEPHYRHILL. I i SHAL'S OFFICF DA C: THIS BUILDING TO BE : Y r ,� W .�• �_: DESIGNED PERMITTED AND CONSTRUCTED AS A SEPARATE 8ET OF DRAWINGS mi mow .. y REMOVE EXISTING CAPSCO JOB f SPRINKLER HEAD LEGEND SYM QTY TYPE FIN Ni TEMP K NPT 1al1`3. MODEL. I SIN DESCRIP11ON I MAX COVERAGE ( EX EXIST UPRIGHT BRASS 155 8.00 3/4" EXISTING EXPOSED / 130 SQ.FT. (THROUGHOUT) 28 PENDENT WHITE 155 8.00 3/4" VIKING M VK -352 RECESSED 1" DROP (E -1 ESCUTCH) / 130 SQ.FT, 28 TOTAL QUANTITY FOR THIS TENANT. ALL HEADS ARE QUICK RESPONSE. t TO SPRINKLER $Y$ l� FLOW SWITCH IY" A a ......... A. A 01100VE CHECK VALVE T ..- HALL MOUNT FDC PIPS DRAIN TO ECM ONSPLASHBLOCK 7-11;1 L INSVEcroRs rEsr a aPnN � cHEcxv�uvEwiowun va.ve arro oaoEa -- CONTROL VALVE WJ TAMPER 31MITCH EXISTING RISER. SEE --- \�N J C* DETAIL THIS SHEET. � suraLv PIPE FINISHED FLOOR EXISTING RISER DETAI NOT i0 SCALE GRAPHIC SCALE ' 0 4 8 18 -- -•— 5' - 0" -=- -- 10' -0" --•- -" 10' -O" _�...�._. 10 IN FEET F IRE PROT PLAN S CALE 1/8" -) t� -oM SCALE: 1/8" = 1' -0" THIS BUILD TO BE DESIGNED, PERMITTED, REFER TO SHEET A102 _...._. _ AND CONSTRU AS .$ FOR COMPLETE LIFE WETY A SEPARATE SET OF I INFORMATION FOR BUIL G _ DRAWINGS -wo B E3 I THIS BUILDING TO BE --�- . THIS BUILDING TO BE GESIGNEt3, DESIGNED, PERMTIEED, ase be advised this revie m of plus submitted is a dory review to assist the contfactor in oonVgam with applicable fire safety codes. 17hi.'s review is not intended to be a final approval of the submitted plans. It is the contfacWs sole responsibility to ensure that the plans are in 00rnplete ompgarm with all applicable NFPA codes and local ordinances. In the event that further examination or site kvspectiorn reveals areas of non— wnpli<nce, it shall be the conbachbes sole responsibility, at their so'e expense to bring those areas in cornpisance. The City mu r no responsibility for Ilia oontractor's failure to be in a ' blix with all appt'rcab'e NFPA Codes and Local ordin 0 81M1 7'I EL' PLANS) HA E BEEN RF VIEWEI : A-Y ZEPHYRHILL. I i SHAL'S OFFICF DA C: THIS BUILDING TO BE : Y r ,� W .�• �_: DESIGNED PERMITTED AND CONSTRUCTED AS A SEPARATE 8ET OF DRAWINGS mi mow .. y .mow _.e�__.r_..._n�w_rw • ..w +_r4rrr.�r..w s" M rt I 2x4 ACT CEILING 1 " x 3/4" R. C. OUARTER POINT SWING JOINT DETAIL NOT TO SCALE BEAM CLAMP ALL THREAD RO 3/8" A.T.R. 4" k Bldg F ;. THIS BUILDING TO BE UESIGNED, PERMITTED, AND CONSTRUCTED AS A SEPARATE SET OF DRAWINGS r 1� ♦ i F D (A.T.R.) OPEN WEB BAR JOIST AND SMALLER FOR 1" THROUGH 4" ADJUSTABLE SWIVEL RING NQIE: HANG MAINS TO TOP CHORD OF JOIST ONLY BRANCHLINES MAY BE HUNG FROM BOTTOM CHORD OF JOIST. OENERAL NOTES: 1. SPRINKLER SYSTEM SHALL COMPLY TN E WI THE 2002 EDITION OF NFPA 13. 2. SPRINKLER HEADS SHALL BE ORIFICE, STYLE AND TEMPERATURE TO MEET CODE, REFER TO SPRINKLER HEAD LEGEND THIS SHEET, 3. SYSTEM TEST SHALL BE WITNESSED BY CITY OF ZEPHYRHILLS FIRE MARSHAL PRIOR TO ANY PORTION BEING CONCEALED. GIVE 48 HOURS NOTICE. 4. HANGERS TO BE PER DETAILS ON THIS SHEET. HANGERS SHALL BE SPACED IN ACCORDANCE WITH 2002 NFPA 13 REQUIREMENTS. 5, ALL WORK SHALL BE COORDINATED WITH OTHER TRADES PRIOR TO FABRICATION. 8. 2" PIPING AND LARGER SHALL BE GROOVED SCHEDULE 10 WITH THREAD --O- -LETS OR GROOVEw -O- -LETS. 1" PIPING SHALL BE THREADED SCHEDULE 40. 2" GRIDDED PIPING SHALL BE GROOVED SCHEDULE 10 WITH THREAD —O—LETS. 7. ALL PENETRATIONS THRU FIRE RATED WALLS SHALL BE PROPERLY SEALED USING UL LISTED METHODS AND APPROVED PRODUCTS TO MAINTAIN RATING OF WALL. In Z O U6- W � r a Y Q m >' m m M 0 4 o U Z 0 0 .�. CA r., ...+ 0 a 8' N " o a-- c� BLOa PERM P REMOVE EXISTING CAPSCO JOB f UPRIGHT SPRINKLER. APPROVAL NEW I" ARMOV£R NEW 1 " 90 ELL I I ARMOVERS GREATER THAN (TYPICAL) I I 24" SHALL HAVE HANGER. £XI51iNG 6 10 1( I" SPRIG EXIS TING 2" I I BRANCHUNE _ - —NEW I" DROP .mow _.e�__.r_..._n�w_rw • ..w +_r4rrr.�r..w s" M rt I 2x4 ACT CEILING 1 " x 3/4" R. C. OUARTER POINT SWING JOINT DETAIL NOT TO SCALE BEAM CLAMP ALL THREAD RO 3/8" A.T.R. 4" k Bldg F ;. THIS BUILDING TO BE UESIGNED, PERMITTED, AND CONSTRUCTED AS A SEPARATE SET OF DRAWINGS r 1� ♦ i F D (A.T.R.) OPEN WEB BAR JOIST AND SMALLER FOR 1" THROUGH 4" ADJUSTABLE SWIVEL RING NQIE: HANG MAINS TO TOP CHORD OF JOIST ONLY BRANCHLINES MAY BE HUNG FROM BOTTOM CHORD OF JOIST. OENERAL NOTES: 1. SPRINKLER SYSTEM SHALL COMPLY TN E WI THE 2002 EDITION OF NFPA 13. 2. SPRINKLER HEADS SHALL BE ORIFICE, STYLE AND TEMPERATURE TO MEET CODE, REFER TO SPRINKLER HEAD LEGEND THIS SHEET, 3. SYSTEM TEST SHALL BE WITNESSED BY CITY OF ZEPHYRHILLS FIRE MARSHAL PRIOR TO ANY PORTION BEING CONCEALED. GIVE 48 HOURS NOTICE. 4. HANGERS TO BE PER DETAILS ON THIS SHEET. HANGERS SHALL BE SPACED IN ACCORDANCE WITH 2002 NFPA 13 REQUIREMENTS. 5, ALL WORK SHALL BE COORDINATED WITH OTHER TRADES PRIOR TO FABRICATION. 8. 2" PIPING AND LARGER SHALL BE GROOVED SCHEDULE 10 WITH THREAD --O- -LETS OR GROOVEw -O- -LETS. 1" PIPING SHALL BE THREADED SCHEDULE 40. 2" GRIDDED PIPING SHALL BE GROOVED SCHEDULE 10 WITH THREAD —O—LETS. 7. ALL PENETRATIONS THRU FIRE RATED WALLS SHALL BE PROPERLY SEALED USING UL LISTED METHODS AND APPROVED PRODUCTS TO MAINTAIN RATING OF WALL. In Z O U6- W � r a Y Q m >' m m M 0 4 o U Z 0 0 .�. CA r., ...+ 0 a 8' N " o a-- c� BLOa PERM P 104 CAPSCO JOB f APPROVAL M B F DRAWN BY- M B F SCALE, AS SHOW DATE; 6 10 1( PP--1 of 1