HomeMy WebLinkAbout10-11069 CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780 -0020 11069
BUILDING PERMIT
Permit Number: 11 069 Address: 38051 MAR SQUARE DR
'Permit Type: COMMERCIAL ZEPHYRHILLS, FL.
Class of Work: ADD /ALT COMMERCIAL Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: CITY OF ZEPHYRHILLS
Est. Value: Parcel Number: 02- 26 -21- 0010 - 03900 -0020
Improv. Cost: 38,500.00 " -; L
Date Issued: 10/25/2010 Name: Name: MARKET SQUARE INC
Total Fees: 430.01 Address: 38135 MARKET SQUARE
Amount Paid: 430.01 ZEPHYRHILLS, FL. 33542
Date Paid: 10/25/2010 Phone:
Work Desc: INTERIOR REMODEL 900 SQ FT
x,. ' al . ' , "un"-'aS s;?, •`a,�, S 7; 7 g tc . ,�.,n
L >
•� - � 'I •� � ILA � _ 51.75
POWERHOUSE ELEC.,INC. PLUMBING FEE 40.00 MECHANICAL FEE 40.00
ASSOCIATED PLUMBING INC FIRE PLAN REVIEW FEES 63.66
SOUTHERN COMFORT ENT. INC.
10 d h ' 9 fp,
i
,:� ��,. >�?t�e. '� � =x,. �'� S ;ate . ���� � ,• N . ��� ��;
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE -METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE -SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection
trips are necessary due to any one of the following reasons: a) wrong address b) condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d) work not ready for •
inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
i • .. - • - is to your property. If you intend to obtain financing, consult with your lender or an attorney
- fore recordin • • ur •'ce of co , • encement."
/` % 4' /1
0 - -I'v TO SIGNATURE PERMIT OFFI tr R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
II!III IIIlI IIII� I�III IIUl I�III iiin hill loll hill iiii iiii
2010153601
Rept:1332362 Rec: 18.50
DS: 0.00 IT: 0.00
10/25/10 K. Garcia, Dpty Clerk
PAULA S.O'NEIL,Ph.D.PpsCO CLERK 8 COMPTROLLER
10 R 5 BK PG
0 8450 c 1380
NOTICE OF COMMENCEMENT
Permit No. itatiSCE
Property Identification No. OZ -1 L - .1 - 00/ d - 0 39DD -Do 217
THE UNDERSIGNED hereby give informs you that the improvement will be made to certain real property, and in accordance with
Section 713.13 of the Florida Statutes, the w follow ing information is provided in this NOTICE OF COMMENCEMENT.
1. Descriptionof property (legal description:) (See. A
a) Street Address: / J.4Ar u4Re_
2. General description of improvements:r,/., es�e .e• ✓,o-/, arms
3.Owner Information w_ I
d
a) Name and address: FMC Maek ua(e, "rr C.. 581 35 m t 5 Zeph Fi 335L
b) Name and address of fee simple titleholder (if er than owner)
c) Interest in property
4.Contractor Information
a) Name and address: / C.D062_ Co 4,1f Ike 0G4- oA{ 3 /eo N[doe e. » G Fi-
b) Telephone No.: J.rz - S7.7 - G o (y Fax No. (Opt.) 336JX
5.Surety Information
a) Name and address:
b) Amount of Bond:
c) Telephone No.: Fax No. (Opt.)
6.Lender
a) Name and address:
Phone No.
7. Identity of person within the State of Florida designated by owner upon whom notices or other documents may be served:
a). Name and address:
b) Telephone No.: Fax No. (Opt.)
8.In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section
713.13(1)(6), Florida Statutes:
a) Name and address:
b) Telephone No.: Fax No. (Opt.)
9.Expiration date of Notice of Commencement (the expiration date is one year from the date of recording unless a different date is
specified):
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF
COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13,
FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.
A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR AN ATTORNEY BEFORE
COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
STATE OF FLORIDA ,ar
COUNTY OF PASCO Y I A STIPPEflT 4aere—
* � * MY CODU OMMISSIONtID738780 Signature of Owner or Owner Authorized Officer /Director /Partner/Manager
WedTh December y, t, , 5 'porr�� Ee %nNA1Mi -Taylor
Print Name
The foregoing instrument was acknowledged before me this AZ day of QIL'> b 6.e i— 20 /v , by at) S
as (type of authority, e.g. officer, trustee, attorney
in fact) for j/- � Sy.I� �, (name of party on behalf o instrument was executed).
/ / /
L
Personally Known OR Produced Identification Notary Sign e , ., O
, ' _ ,
Type of Identification Produced /t:Sona.2L7 ry^,owi'1Name (print) clgieJEft) A. S z� tOper •
•
Verification pursuant to Section 92.525, Florida. Statutes. Under penalties of perjury, I declare that I have read the foregoing and that
the facts stated in it are true to the best of my knowledge and belief.
r
roRMS Noc. wezoo7 Signature of Natural Person Signing Above
I t
L A W Y E R S T I T L E
I N S U R A N C E C O R P O R A T I O N
N A T I O N A L H E A D Q U A R T E R S
R I C H M O N D , • V I R G I N I A
OR BK 8450 PG 1381
Schedule •A• Lands 2 of 2
That portion of Tracts 39, 40, 41, and 42, ZEPHYRHILLS COLONY COMPANY LANDS, in Section 2,
Township 26 South, Range 21 East, as per plat thereof recorded in Plat Book 1, page 55,
Public Records of Pasco County, Florida, described as follows:
Commence at the S.W. corner of the N.W. 1/4 of said Section 2, thence run North 0 degrees
13' 24" West, along the West boundary of said Section 2, 662.75 feet, thence North 89
degrees 54' 51" East, 112.0 feet to the Easterly boundary of the Right -of -Way (R /W) of
U.S. Highway No. 301, for a POINT OF BEGINNING: thence run North 0 degrees 20' 42" East,
382.70 feet along said Easterly R /W, thence run North 89 degrees 57' 16" East, 150.0 feet,
thence North 0 degrees 20' 42" East, 200.0 feet, thence North 89 degrees 57' 16" East,
291.72 feet, thence North 0 degrees 02' 42" West, 20.0 feet, thence North 89 degrees 57'
16" East, 449.44 feet, thence South 0 degrees 00' 04" West, 568.70 feet, thence North 89
degrees 54' 51" East, 38.34 feet, thence South 0 degrees 13' 24" East, 3.70 feet, thence
South 89 degrees 54' 51" West, 45.82 feet, thence South 0 degrees 13' 24" East, 30.0 feet,
thence South 89 degrees 54' 51" West, 887.26 feet to the Point of Beginning.
LESS AND EXCEPT:
That portion of Tract 41, ZEPHYRHILLS COLONY COMPANY LANDS, in Section 2, Township 26
South, Range 21 East, as per plat thereof recorded in Plat Book 1, Page 55 of the Public
Records of Pasco County, Florida; described as follows: Commence at the S.W. corner of
the N.W. 1/4 of said Section 2, thence run N. 00 °13'24" W., along the West boundary of
said Section 2, 687.75 feet, thence N. 89 °54`'51" E., parallel with and 25.0 feet North of,
the South boundary of said Tract 41, 297.22 feet for a POINT OF BEGINNING; thence continue
N.89 °54'51" E., 40.0 feet, thence N.00 °20'42" E., parallel with the East boundary of the
R/W of U.S. Highway No. 301, 75.0 feet, thence S.89 °54'51" W., 40.0 feet, thence
S.0 °20'42" W., 75.0 feet to the Point of Beginning.
•
STATE OF FLORIDA, , COUNTY OF PASCO .
THIS IS TO CERTIFY THAT THE FOREGOING IS
TRUE AND CORRECT COPI"`OF THE DOCUMENT
ON FILE OR OF PUEPQ 'RECORD IN,TH(S QFFICE
WITNESS MY HANDA OFFICIAL`S LTHIS
?"'` DAY OF ' 1 Z n�i ° 2 (
PAULA S 0' - L, CLERK & COIMPTRQLLER
BY DEPUTY.gLERK
Commitment No.9302698
ZEPdYRHILLS FIRE DEPARTMENT
6907 Dairy Road, Zephyrhills, FL 33542
Fire Chief Keith Williams Bus (813)780 -0041 Fax (813)780 -0044
FIRE SERVICE USER FEES
Occupancy No.:
Plan No.: /JO - JZ� -7
' Contractor: /.���/y 1 ,S ,i ®yj
Business Name: pi t° a�� c7 r Billing Address: 3'7f o /jj /.0-19.,r_
Business Address: me,ia /.. .
Business Phone No.: Am. L/.:ce.,_ _ - Billing Phone No.:
Business Fax No.: Billing Fax No.:
Contact: Contact:
PLAN REVIEW FEES _ INSPECTION FEES _ PERMIT FEE _ FALSE ALARM FEE
fra Site Plan N/C — Annual N/C — Sprinkler $50 ` 1st Alarm N/C
Multi Family /Commercial 1st Re- inspection N/C Standpipes $50 _ 2nd Alarm N/C
(Minimum Charge $25. 2nd Re inspection $100 _Fire Pump $50 _ 3rd Alarm N/C
0 Plan Revisions DBL _ 3rd Re- inspection $250 — Hoods $50 _ 4th Alarm $100
_ 4th Re- Inspection $500 — Fire Alarm $50 —
5th Alarm $150
SPRINKLER SYSTEMS (Business closed until _ LP Gas $50 _ 6th Alarm $200
_ 0 - 25 Heads $50 violations corrected) _ Natural Gas $50 NON COMPLIANCE $150
— 26 plus Heads $100 — SPRINKLER SYSTEMS Fuel Tanks- Per rank $50
STANDPIPE SYSTEM _ Hydro Undergrounds $45 _ Sparklers $100
0 Per Riser $50 — Hydrostatic Test $65 per system _ Fire Works $500
FIRE PUMP _ Acceptance Test $45 per system _ Camp Fire $25
0 Per Pump $100 Hydrant Flow $75 _ Controlled Burn $100
FIRE ALARM SYSTEM Hood /Duct $50
—
0 - 25 Devices $50 FIRE ALARM SYSTEM _ Place of Assembly $50 Annual
26 plus Devices $100 — System Acceptance $50 Fire Protection $25
SUPPRESSION SYSTEMS _ e Recall Acceptance $50 — Flammable Application $50 Annual
_ Wet $50 _ OTHER Waste Tire Storage $50 Annual
— Dry $50 r Fire Wall /Smoke Wall $15 per wan _— Generator < KW $100
CO2 $50 — LP Gas $25 per tank — Generator >30 KW 150
— Other $ — Natural Gas $25 per system Bio- Hazard Waste
$100 Annual
KITCHEN EXHAUST — Fumigation Tenting $50
0 Hood /Ducts $50 _ Tent 105(10' or greater $15 per tent Torch Pot/Applied $50
OTHER _ Fire Pump $45 _ Haz. Materials $100 Annual
— LP Installation per tank $50 _ Fire Suppression $30
— Fuel Tank Installation $50 _ System Acceptance
(Per Tank) $50 _ Exhaust Hood/Duct $30
0 Natural Gas Installation $50 — Re- inspection DBL
(Per System) (other than annual)
0 Spray Booth $50 El Inspection scheduled DBL
and cancelled less than
_ 24 hours
— Construction Insp. N/C
Emergency Vehicle Ac $50 FALSE ALARM
PLANS TOTAL / INSPECTION TOTAL I 1 PERMIT TOTAL - 1 TOTAL
N GRAND TOTAL 1 63 ,
Comments:
Date: /6/� /�
Insg ctor: �/ y� �
813-780 -0020 City of Zephyrhills Permit Application ��'ttt�� / /�, Fax -813- 780 -0021
Building Department lC� I/0 ( I
Date Received )- -/ (� Phone Contact for Permitting - 4 - , U ,
Owner's Name / /o4 * DR /7 ) O C.e.vie Owner Phone Number
Owner's Address 3•00,57 4JCt/- -57 t' QL= I Owner Phone Number
Fee Simple Titleholder Name 1 Owner Phone Number
Fee Simple Titleholder Address 1
JOB ADDRESS , �^- ,9 /e T 52 tl AR e. LOT # L 5)J2..L J 1
SUBDIVISION PARCEL ID#
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED I I NSTALL S TR I (
REDAIRLT It'' SIGN 1 1 ( 1 DEMOLISH
PROPOSED USE I I SFR n COMM 1 1 OTHER ( I
TYPE OF CONSTRUCTION I I
BLOCK n FRAME I I STEEL 1 1 1 I
DESCRIPTION OF WORK A/ l tuat O2 �e4iC V.` 1 / L' Al
BUILDING SIZE SQ FOOTAGE 9 HEIGHT
I BUILDING $ 364 D DV VALUATION OF TOTAL CONSTRUCTION
I / IfzCE $ 6 V 6 AMP SERVICE I 1 PROGRESS ENERGY W.R.E.C.
P MBING $ i„ ijdi
rECHANICAL $ VALUATION OF MECHANICAL IN�3T,f) ALLATION ,� Q�
1 IGAS 1 1 ROOFING n SPECIALTY 1 1 OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA 1 'YES NO
BUILDER - .. COMPANY % �2&-� l_.a �'c - i ----4,e-3 C' I SIGNATURE // .. REGISTERED Y/ N I FEE CURREIN I Y/ N 1
1
Address 3 c 2 0 ear, 2r ,2 . License #C Illy b y/ ` 2 ' T_
/
ELECTRICIAN Cam r L�, COMPANY 47 J O 5f� E/ �
SIGNATURE Frelimi REG ISTERED 1 a/ N I FEE CURREt I Y / N
Address 1 7 71- s.. (4 ! 32 /1 C / .3g5 GJ 3 License # e/eoo l 57 C
PLUMBER <e, Le iei COMPANY ,TSSOCit ea P/ICOLL)ve/ •T- 1.02.-
SIGNATURE �/ REGISTERED I Y/ N I FEE CURREI' 1 N I
Address 0/ 7 / / / afr�0� 'fL( „Sk. < I ®k+tt Ci4 I A 33503 License # £ r--C n _ L 67); O'
MECHANICAL - - � /-/ / COMPANY 5O ✓"r X e.-ti Ca :Z.- -A4. T EL, Z -
SIGNATURE /��/,/�/ �/ REGISTERED I Y/ N I FEE CURREN I Y/ N 1
Address 1 /140 g C fZ Lo S C JeJ15 tee License # I CAC i p / $ f
OTHER COMPANY
SIGNATURE REGISTERED I Y/ N I FEE CURREI\ I Y/ N 1
Address License #
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R -O -W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions /large projects
COMMERCIAL Attach (3) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R -O -W Permit for new construction.
Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed,
Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance
SIGN PERMIT Attach (2) sets of Engineered Plans.
* ** *PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner & Contractor sign back of application, notarized
If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500)
** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (Front of Application Only)
Reroofs if shingles Sewers Service Upgrades NC Fences (Plot/Survey /Footage)
Driveways -Not over Counter if on public roadways..needs ROW
I
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division — Licensing Section at 727 -847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT /UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned Understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89 -07 and
90 -07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water /Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law — Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the "owner ", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the "owner" prior to commencement.
CONTRACTOR'S /OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection - Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District - Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers - Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services /Environmental Health Unit - Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency- Asbestos abatement.
- Federal Aviation Authority- Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone "V" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A ", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for Tots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to . violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LEND : •RAN ATTO • NEY ' EFORE RECORDING YOUR NOTICE OF C ENCE NT.
FLORIDA JURAT (F. .117.03)
OWNER OR AGENT CONTRACTO
Subscribed and s • to (or - " me• before me this Sep Subscribed and sw• o (outfit' -d) be • e me this
30, 20/0 by 'boo • 'reticle 34 2 - 0J€1L
o is/Are personally known to me or has/have produced Who Is /are personally known to me or has /have produced
�J , f 9 L € ' c "ra$ as identification. tz Drive vi Lr« as identification.
-A( AM Notary Public Notary Public
mission , cblJ � l as J 7 Comm '. - .• .
�� �Io���
:`4n - {{ /kJ
Name of Notary typed, printed ^� ^F ^'w ' flame of Notary typed, printed or stamped AV JANICE M. HELMS
;yF! "i,`_ JANICE M. HELMS ? .r MY COMMISSION # DD 922207
;.. '!u .r_ MY COMMISSION # DD 922207 ';.�. , EXPIRES: September 10, 2013
EXPIRES: September 10, 2013 ' 'Ape f•' Bonded Thru Notary Public Underwriters
i fite Bonded Thru Notary Public Underwriters
38051 Market Sq. Dr.
SQ. FEET PRICE
MAIN OR LIVING:
OTHER AREA UNDER ROOF:
OTHER: - $ -
VALUATION $ 38,500.00
FEE SHEET $ 230.00
ADDRESS
DRIVEWAY
BUILDING: $ 234.60
ELECTRICAL: $ 51.75
PLUMBING: $ 40.00
MECHANICAL: $ 40.00
SUB -TOTAL $ 366.35
RADON: $ -
TOTAL $ 366.35
SEWER:
WATER:
IRRIGATION: $ -
TOTAL: $ .
WATER METER:
IRRIGATION METER $ - I
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE
FIRE
5% $ -
TOTAL: $ -
I SUB -TOTAL $ 366.35I
PARK IMPACT FEES $ I
SIF'S: $ -
100.0% $ -
1.0% $ -
TOTAL: $ -
TIF'S:
99% $ -
1% $
TOTAL: $ 366.35I
�
City of.Zephyrhills
BUILDING PLAN REVIEW COMMENTS
ontracto1l Iomeowner: /, a h1 �G/ per - .
Date Received: , ,i - /D
Site: c� / or
Permit Type: ..f,4if l � -v/ z- ±'7 ,
Approved w /no comments Approved w /the below comments: ❑ Denied w /the below comments: ❑
This comment sheet all be kept with the permit and/or plans. [0 Is_tO
,14
Kalvin
SL itzer - s Examiner Date Contractor and/or Homeowner
(Required when comments are present)
Sep 30 2010 . 10:55AM TEDDER - CONSTRUCTION -INC 3525210096 p.3
•
Proposal Contract
TEDDER CONSTRUCTION INC.
37420 MOORE DR.
DADE CCTV FL. 33525
(352)567 -6084 CBC1253041 FAX (352)521 -0098
TO: Florida Medical Center DATE: 08 -25-10
Dermatology 'Building (8)
Zephyrhf lls fl.
thereby submit epeeltoations end estimates for Renovations on building (b)
1, Demo existing area as needed includes cabinets ,soffits,dtyweli,doore,glasa and electrical.
2. Remove carpet and concrete for new sinks four total as per drawing and reinstall.
3. Install four bar type sinks 15" x 15" w /goose type faucets as per drawing.
4. All cabinets built and installed by fmc.
5. Replace ceiling same type as existing.
6. Install new t-8 type lights in area as per drawing 17 total.
7. Install exit signs and emergency lights as needed per drawing.
8. Frame approx. 164 If of 9' walls as per drawing.
9. Drywaii area w/ 1/2" drywall as per drawing all smooth finish.
10. Install a/c vents and returns as per drawing existing service will be used.
11. Install electrical outlets and switches as per drawing existing service used.
12 install boxes for data as per drawing.
13. Install seven 38" x 8'8" birch doors and hardware as per drawing
14. Remove four doors frame and finish as needed.
15. install 2- 4' x 7' reception windows as per drawing.
18. Supply building permit and engineered drawing by watson design.
17. All fire system changes done by fmc and signs.
propose hereby to furnish materiel and labor - complete In accordance wish above specifications, tor the sum of
Thirt One thousand e' • 1 hundred nine six and oohs --.— 31 898
Payment to be made as fogows
. 30% upon aoceptance 40% when�h plumbing installed 30% upon • m • Ietion
All
materiel M guaranteed to be as :pacified. At work to be completed � P
h a workmanlike manner eccordhp to standard practices. Any pipers.
Lion or deviation from above specifications hvoNflg wire cast will be . 7. ' !.!f — 41 71 a "
executed only upon written orders, and will become an extra charge withdrawn • if not aeoepted
over end above the eatirnale. dep.
Acceptance of proposal - The above price', speolloationee end cordklone are
satisreotory and are hereby accepted. You are authorized to do Ile work es apedned. Signature
Payment wig be as outlined above.
Signature
•
Zephyrhills Fire Rescue
6907 Dairy Road. Zephyrhills. FL 33542
Fire Marshal Bus (813) 780 -0041
Kerry Barnett Fax (813) 780 -0044
E-mail: kbarnettci ',iirc.zephyrhills.tl.us
Plan Review #: 10-1 17
Project: Interior Renovation
Pages: 3
October 6, 2010
I have received and reviewed the plans for the interior renovation located at 38051 Market
Square Drive and have rejected them at this time. Reasons for the rejection are listed below.
No fee has been assessed at this time and those fees will be assessed at the time of the
revision. An additional fee will be assessed for completing work at the site without having
an approved permit. Should anyone have any questions, please do not hesitate to contact the
Fire Marshal's office.
1. Plans submitted appear to either be drawn wrong or dimensioned wrong. Room sizes
appear to be different on plan than what is actually there. It also appears an office has
been missed. There are doors that have been added within the last 2 days that were in
existing areas not shown on the plans. (contractor may need to meet fire marshal at
site to understand)
2. Separate plans will be required to be submitted for the fire sprinkler modification to
obtain a permit. Plans, cut sheets, details, etc... will need to be submitted.
3. If the fire alarm system is to be modified so that audible and visible devices are
properly heard and seen, separate plans will be required to obtain a permit.
/if
Anvata
KERRY B -• ' E f , FIRE MARSHAL
** *Please be advised this review of plans submitted is a cursory review to assist the contractor in
compliance with applicable fire safety codes. This review is not intended to be a final approval of
the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in
complete compliance with all applicable NFPA codes and local ordinances. In the event that
further examination or site inspection reveals areas of non - compliance, it shall be the contractor's
sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no
responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and
local ordinances.
' I
Zephyrhills Fire Rescue
6907 Dairy Road, Zephyrhills, FL 33542
Fire Marshal Bus (813) 780 -0041
Kerry Barnett Fax (813) 780 -0044
E -mail: kbarnett @lire.zephyrhills.fl.us
Plan Review #: 10 -122
Project: Revision — Interior Renovation
Number of Pages: 3
October 14, 2010
I have received and reviewed the plans for the interior renovation located at 38051 Market Square
Drive and will allow it to move forward. Paying for permit, contractor acknowledges complying
with the items listed below. Should anyone have any questions, please do not hesitate to contact
the Fire Marshal's office.
1. Plans shall be submitted for the modification of the sprinkler system. Cut sheets shall be
provided on any new heads, piping, etc.... This will allow a permit to be obtained.
2. Plans shall be submitted for the fire alarm modification. Contact Fire Alarm Company to
ensure there are adequate notification devices based on the new layout. Cut sheet shall be
provided on the new devices being added. This will allow a permit to be obtained.
3. Ensure there is a certified extinguisher within 75' of travel in a visible location.
Inspection(s) Required:
1. Final
1 1'
�� � ;V
KE 1's' ' NETT, FIRE MARSHAL
** *Please be advised this review of plans submitted is a cursory review to assist the contractor in
compliance with applicable fire safety codes. This review is not intended to be a final approval of the
submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance
with all applicable NFPA codes and local ordinances. In the event that further examination or site
inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole
expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure
to be in compliance with all applicable NFPA codes and local ordinances.
a
n
7�
j
4
m
vn
J
z
u
Q
(z
w
�?
ci�4
U
� Q
3
O�
xu
Fz
�
z
lu
z a
�
O
3 o Q
O
fl0y
~Q
J
X
ez
'
w�
�4
�
u
z
qq
�zd
z z
w
Q
03
Q
g
m
u
a
n
7�
j
4
m
vn
J
z
u
Q
OL
O
O
IL
z
0
F-
(3
w
Q
w
}
u.i
ff
w
�7
z
Q
u
0
F-
B
z
N
4l1
N
A
U
A
(z
w
�?
ci�4
U
_Q
�
xu
Fz
�
Q
�Q
lu
z a
x�z
za
3 o Q
O
fl0y
~Q
J
X
ez
'
w�
�4
�
u
z
qq
�zd
z z
w
Q
03
4
m
OL
O
O
IL
z
0
F-
(3
w
Q
w
}
u.i
ff
w
�7
z
Q
u
0
F-
B
z
N
4l1
N
A
U
A
g o
�N
Ca _L to N
o `er C=
J C
L�
\ ti
V
0
i�
3�
L
N
U4
Q
cn
J
u
JI
U
z
n _..t
O
O
O
H
U
lu
w
t�l
F-
Q
O
DO
(Y
PQ
z
0
Oy
Z�yt�4
Z�MM
y m Q Q W
Qytiw� "
3avcvQ
���NZ
��
0
r
O
O
O
Q
V
z
O®
D O
L
zz
V5 LLI
LU
0
D
H
co
z
O
O
uj
w
V
z
J
V
J
Q
V
O
W
Q
O
LL
w
N 0
w
uj
F—
z
z
W
�a
QD
CL -J
W V '
0�
}- J
� J
Os
J �
O �-
Q (.
45 N
W
a
PG
1 OF 3
0
M
c
y
2
W
�n
O
O
z
`�i
Q�
Q
Q�
�?
z�
Qm
_Q
4=
Q-w
xu
Fz
l � XX
8M
3
OW
Q �p Ow R'
cO4
J
X
4
z �
u
Q
w
Q
03
F�
zd
Qm
xu
QDO
DO
O
o�
o u�o
V 4
c04
3
g o
�N
Ca _L to N
o `er C=
J C
L�
\ ti
V
0
i�
3�
L
N
U4
Q
cn
J
u
JI
U
z
n _..t
O
O
O
H
U
lu
w
t�l
F-
Q
O
DO
(Y
PQ
z
0
Oy
Z�yt�4
Z�MM
y m Q Q W
Qytiw� "
3avcvQ
���NZ
��
0
r
O
O
O
Q
V
z
O®
D O
L
zz
V5 LLI
LU
0
D
H
co
z
O
O
uj
w
V
z
J
V
J
Q
V
O
W
Q
O
LL
w
N 0
w
uj
F—
z
z
W
�a
QD
CL -J
W V '
0�
}- J
� J
Os
J �
O �-
Q (.
45 N
W
a
PG
1 OF 3
0
M
c
y
2
W
�n
O
O
z
`�i
I X
O
O_
-1
111
ul U
Q O_
� O
o Q
U
z Z
O
U
Q
LU
Lu
ff
u,
0-
�� �w � w �
A Q O � O �n cry
� U
d
U
�m �m o
u- t=d I11� � Q d3
J 3
0
z
U
z
d
Al
Q!/
LU
O
Q-
O
v
LU
cn
Q
LU
w
�y
Z
O
0 z
cm
y
>
U
M
O
o
H
a
wA
z
LLJ
z�
a o► -
z
qq
LLI
o
z
O
e�-
n os
LUI q
�Q
4
O
a�
a
�y
Z
O
1
1
cm
y
W
M
O
(A
. 1
H
t4
t4
Q c Q.l
wy
O
o
z
O
4
O
�
�
o
Y-
z o
d CID
z
Q A
V
z
z d
O❑
V�
DJ
�LL
z �
O V
vw
o®
❑
w
z
Q
O
w
O
Lij L.L.
z
VW
220
J �...
V
J a.. J
Q W LL
V
J
LLI
o _
d J �
O
.�N
LL. W
❑
PG
2OF3
l�l
O
m
ttl
O
BOTTOM CORD OF CEILING BAR JOIST
0
BOTTOM CORD OF CEILING BAR JOIST
3 5/8" 20 GA TRACK ATTACHED
TO BOTTOM CORD OF TRUSS WITH
3 5/8" 20 GA TRACK ATTACHED
\-T0BOTTOM
C (2) •8X1 1/2 SCREWS. SECURE STUD
,
CORD OF TRUSS WITH
TO TRACK WITH (1) •8X1 SCREW AT
(2) 0 6X1 1/2" SCREWS, SECURE STUD
EACH SIDE
TO TRACK WITH (1) "8X1" SCREW AT
EACH SIDE
DROP CEILING SYSTEM
O
L
DROP CEILING SYSTEM
O
1/2" GYPSUM BOARD
1/2" GYPSUM BOARD
ON EACH SIDE OF STUD
ON EACH SIDE OF STUD
ttl
0 3 5/8" 20 GA STEEL STUDS 16" OC ~
0
3 5/8" 20 GA STEEL STUDS s 16" OC
a
3 5/8" 20 GA TRACK ATTACHED
TO CONCRETE FLOOR WITH (2)
'8X1" TAP CONS SCREWS tv 24"
OC, SECURE STUD TO TRACK WITH
(I) 0 8X1" SCREW AT EACH SIDE
TYPICAL STEEL STUD DETAIL #1
NOT TO SCALE
2X4 0 2 SPRUCE TOP PLATE ATTACHED
TO BOTTOM CORD OF TRUSS WITH (2)
16D NAILS
DROP CEILING SYSTEM
1/2" GYPSUM BOARD
ON EACH SIDE OF STUD
2X4 •2 SPRUCE STUDS 0 16" OC
2X4 P,T, BOTTOM PLATE ATTACHED
TO CONCRETE FLOOR WITH (1) "8X1"
TAP CONS 24" OC
TYPICAL WOOD STUD DETAIL #1
NOT TO SCALE
BOTTOM CORD OF CEILING BAR JOIST
0
3 5/6" 20 GA TRACK ATTACHED
TO CONCRETE FLOOR WITH (2)
"SXI" TAP CONS SCREWS s 24"
OC, SECURE STUD TO TRACK WITH
(I) "8X1" SCREW AT EACH SIDE
TYPICAL STEEL STUD DETAIL #2
NOT TO SC
BOTTOM CORD OF CEILING BAR JOIST
2X4 0 2 SPRUCE TOP PLATE ATTACHED
TO BOTTOM GRID SYSTEM WITH (2) MSX2"
SCREWS OR ZIP STRIP
DROP CEILING SYSTEM
1/2" GYPSUM BOARD
a ON EACH SIDE OF STUD
lA
2X4 0 2 SP RUC E STUDS 9 16" OC
0
o�
2X4 P.T. BOTTOM PLATE ATTACHED
TO CONCRETE FLOOR WITH (1) "8X1"
TAP CONS 24" OC
TYPICAL WOOD STUD DETAIL #2
NOT TO SCALE
REVISED SECTION LIFE SAFETY PLAN
11411 11 OI1
1
Ntb
y
Z�N�O
Z�MM Q
y o�p
OW°����
cS �0
3
Z0 N2 W
W y
O
4
Q Q
O r
N Q
� O
A�
� Q
QZ Q
W'
a F—
Q Q
al
T
c�
z
V
_Z
Z
Op
V�
= o
�LL
�>
z �--
0�
Lu
Lu
pp
p
W
Z
_0
0
Z
w
w
w
_O
W
Z
F--
VW
Q
220
-J a. Q W L-
Vp�
W J_
�0=
p 0�
�a0
.�N
LL. ui
p
PG
30F3