Loading...
HomeMy WebLinkAbout6819 OAK CREST WAY City of Zephyrhills Building Department "Standard Code Reference" • Each bedroom shall have at least one window sized for emergency egress: 1997 Standard Building Code #1005.4.4 • Window glass within 60 inches of drain height in walls that enclose a tub /shower shall be tempered: 1997 Standard Building Code #2405.2 • Attic ventilation shall comply with 1997 Standard Building Code #2309.7 • Installation of overhead garage door shall comply with Chapter 16 of 1997 Standard Building Code: (100 mph wind load) • Dryer exhaust installation shall comply with 1997 Standard Mechanical Code #509.3 • Range vent installation shall comply with 1997 Standard Mechanical Code section 508 • Access to mechanical equipment installed within a attic shall comply with 1997 Standard Mechanical Code #304.4 • Water heater installation shall comply with Chapter 5 of 1997 Standard Plumbing Code. David Johnson 6819 Oak Crest Way Electrical Notes 1999 Electrical Code 210- 11(c)(3): Bathroom receptacle circuits shall have no other outlets 210- 52(c)(1): No point in a wall shall be more than 2' from an outlet 210- 52(e): Receptacles shall be located at both the front and rear of the dwelling 210- 8(a)(2): Garage receptacles shall be GFCI protected 210- 8(a)(3): Outdoor receptacles shall be GFCI protected 210- 8(a)(6): Receptacles that serve kitchen counters shall be GFCI protected 240 -24: Location of panel 250- 50(c): Footer steel shall be grounded 410- 57(a): Receptacles in damp locations may have an enclosure that provides protection from the weather only when closed 410- 57(b): Receptacles in wet locations shall have an enclosure that provides protection from the weather when closed or open CABO 316.1: Smoke detectors shall be installed in each sleeping room, outside of each sleeping area in the immediate vicinity of the bedrooms CABO 316.2: Required smoke detectors shall be supplied by A/C current and have battery backup 03/18/02 2:17 PM j 0 - - - - - - - - - - - - - - - - - - - - - - - - - - - PATIO FIELD VERIFY 6'­0" SL ON6 IF FIBERGLA88 el-IINGLES l / _1E L LE: L L ill i I I 1 I L ­4 1 1 FRONT ELEVATION a *ALE EtSRE68 WITH EYEBROW L..'t�L '9^TA 16'"Xi6" ecowmNs '.O' ABOVE FIN16HED FLOOR HEIGHT 24' 0' i ( ` 811JCCO TEXTURE FiNIS1 3) RIG HT ELEVATION LIVING AREA 1502 GARAGE 441 ENTRY 50 e)F - TOTAL I9 8F q &c' 0 1)k 4 ALL WORK SHALL COMPLY MAR 18 2002 F WITH ALL PREVAILING CODES, STANDARD BUILDING., PLUMBING) ���'� MECRANICAL, N.E.C. AND CITY 5e- 1/4" 1'_O' OF ZEP[IYRHILLS ORDINANCES. APPROVED PRINT REQUIRED LEFT ELEVATION 5oA1..E: '14' - 1'-0' ON JOB SITE ALL THE INFORMATION ON TH18 PAGE 16 INTENDED TO BE CORRECT BUT M18TAKEO CAN BE MADE AND IT 16 THE RESPONSIBILITY OF THE I HMMY CERT[W IMT I HAW RWl0ffi0 CIO PLAN AW Po" iT To M IN CONTRACTOR TO VERIFY ALL INFORMATION PRIOR TO CONSTRUCTION. WE WILL BE AVAILABLE TO HELP REeOLVE ANY PROBLEMS. coomnlAWI WITS WOUM W06 OF TM OTAWAM WWM 0 0M ifflwl WMON, REAR ELEVATION as O 54 -l ' . 411 1 II 1 ❑ I ❑ 11 Il -4 I3 -10 E2 -8 4 dl _7 a 11 _7 I r - -- -- ----- -- - - -i r --------------------------------------------- PATIO FIELD `✓ERIFY / ' PATIO FIELD VERIFY ; i 1 I S' -0" 8L ►DING 3' -0" SLIDING 8H 22 T MPERED r ---- _---- J-------------- - - - - -- - - - - - - - -- ------------------------------- _------ - - -�� / o HB _, ----------- -- - - --- � ° - �-- - - - - ^8_ ErRE$8 0 - - -� - - - - - -- r-- - - - - -- ; - - - - - - -- - T - r - °I I o a r ------ - --- ---------- ---- - ------- --- -- --- - - - --- - - --- -- - - -- -- ------- ------- - - - -- -- -- - - _'�-� -_____ -T _ -------- --------------------- -- - - -- Or 1 1 - - - I it 1 1 / I i I I Y '-- -- --- -- --- --' I � 1 I I I I Li I I FILLED CELL SYMBOL l/ ' 1 7 I 1 4'/ 2500 PSI MONOLITHIC CONCRETE BLAB WITH 6X6 I0 WIRE MESH ° I OVER b MIL, Vi&XEEN VAPOR OARRSR AND CLEAN,TREATED (- „� i AND COMPACTED FILL TO A MIN. 2500P8F (F!BERME6" OPTIONAL) ; I I I 1 I I 1 I 1 1 I I I I 1 •I I I- - - - - - - - ' - - - - - - - - - - - - - - — +� 1 a C. NOTE: PLUMBER TO VERIFY I LOCATION OF FIXTURES. 1 I 1 r 1 I I 1 , ° I I I I 1 1 I I I I r 1 I I I 1 1 r ---- -------- - ---- I r - - --- - -- - - _ -' I , --- ------ ----------- ------- -- ---2 L ----------------------------------_----- I - _ _ _ _ ' "- - -,, --------- - - - -- - - - -- L - - -- - -- -- - - - - -- DBt 614 21JE EC�RE68 ------------- - WITH f= YEBROW WITH EYEBROW - L - -� DROP BHOW'ER 0 - I ". STEP -DOWN 4' ; 8'X24" FOOTER PAD ,( W/►5 RODS 12" EI11 16 "X ?b" COLUMNS ' 10' ABOvE FINISHED FLOOR HEIGHT , 1 1 I 1 I I I 1 I I 1 8'X ?6' CONT. 2500 P61 CONCRETE FOOTER WITH 2 0 5 REBARS ON ROD CHAiRB AND UPRI(SHTS BENT AND T;ED A MIN. OF 25 ". - 8' O.C. MAXIMUM SPACING AND BE610E ; ' EACH OPENING. , CA I I 1 1 1 1 1 ° I 1 I I I I 1 1 1 I I 1 I I ( I 1 I 1 I I 1 I ( 1 I I 1 I 1 1 1 1 I I I 1 I 1 1 I � 1 I I 1 I 1 1 1 - - ------------ -------- - ----- - --------- - f00 MH WINDRATiNG ON OOR - - I 1' of /j' I , — � I L_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ - - _ - _ - _ _ _ - _ - _ - _ - - _ _ - _ _ _ _ _ - _ I 10 -8" 6' -4" I 5' -8" I 4 -8" 9' -0II T-o" 1 X4 1 -0 11 FOUNDATION PLAN DRAWN BY 12 8 HANLEY 4 CA SCALE: 1!411 " 11 -0" - - -- ---- - - - - -- -- -_ —_ PAC E 2 - j r — - - - - - -- - -- - - -- — F10ERGLA88 SHINGLES ! i *30 ROORNG FELT DOT. PITCH ON ELEVATIONS � l 1/2' CDX PLYWOOD NAILED W /80 COMMON8 j b OC ON i j FABTENERB PER ROOF LAYOUT ��= / PRE ENG. TRUSSES 24'0 C MAX 6PACiNG / i I !GC `iPi - '.11iND LOADING R -25 INSULATION I i ALUM. GRIP EAV E ,j - - -- - -- - - -- -- - 1 1f T 1/2" EIL iNG DRYWALL ! 2X6 SUB- FASCIA � VINYL SOFFIT AND FA8GIA I h T 1/2' DRYWALL OVER ?X2 PT 3TRIFPING AND 3/4 RIGID INBULATiON I I PRECAST LINTEL AND ili_�I j I LINTEL £LOCK WITH F (1) I'5 REBAR CONT. I OF HOUSE . } j I li i SINGLE HIiNG WINDO1ll8 I w I� -al i 'al PRECAST BILL I ; I STUCCO FINISH 1 - - - - -- - - � - - - 4 "/ 2z • P51 MONOLITHIC CONCRETE BLAB WITH 6X6 10 /10 WIRE MEBN OVER 6 MIL. V18XEEN VAPOR f'3ARR ER AND CLEAN,TREATED 8"X:6" CONT. 2511 PSI CONCRETE FOOTER AND COMPACTED FILL TO A i'11N. 250OPSF (FBERI` ESH OPTIONAL) WITH 2 0 5 REBARS ON ROD CHARS AND UPR14SHT6 BENT AND TED A MIN. OF 2S ", 8' O.G. MAXIMUM SPACING AND BESIDE EACH OPENING, TYPICAL WALL SECT ION - - - -- - -- - - -- - - - - - -- - - -- 1/2" CDX CR OSB 5�_AT"!N( NA :LED b" OC CN ALL EDGES ADD iN T:-E FIELD GABLE TRUSS BRASiNG FER 'RU83 COQ - F'ANY i 2X4 D'AGONAL 43" O G NAILED WIT:4 (2) 12d S0 1''1"CN5 Y` - - -- AT TOP CI✓CrrD C= TRU39, BOT70M St- -CRD OP TRUSSAND INTO SICE OF 3TR(NGER PROVIDE '.6d NAILS 6" O.0 2x4 STRINGER 4a' O C NAILED III i � FROM BOTTOM CHORD TO PLATE (2) I2d COM`"ONS IN EASLI TRGSa_,' FROViDE Sd NAILS FROM SkEATHING - - - - - - - - -- f0 BOTTOM CHORD 4" O.C. j I i I 1/2 CEI' •NG CRYLIALL t 2X8 PT PLATE / _KT BLOCK WALL 2x4 BLOC <iNG SET TRU35ES 4a' O C NA LED 1JITN (2) I2d NAILS EACP END I I 1/2" X 8" J -BOLTS 4 I j GABLE BRACING DETAIL I I ' I I ' r - --- ---- --- --- --- --- --- -- -- - --- -- I - - - - -- - - 24' OVERHANGS -- - - - - -- -- - - - - - -- - -- - � I I I , I I ATTACH TRUSSES TO BEAM6 I AND KNEEIL'ALLS AROUND ENTRY j WITH H -3 HI:RRICANE T;E BY SIMFSON 31MFSON LU846 OR EOUAL. I 1 i T - I ATTACH BEAMS AND KNEE.UALL3 TO LINTEL WITH HETA-n j STRAPS AS NOTED I I II I I ! OR EOIJAL, r ----- --- — 4,T -- - -- - IT - - r - -- - - -- - -- -- -- - - - -- -- 1 I I I USE (1) t4ETA20 TRU68 ANCHOR PER EACH END OF EACH TRUSS EXCEPT A6 NOTED. I !00 MPH WIND LOADING ATTACH TOP PLATE OF KNEEWALL TO STUDS AND BOTTOM PLATE WITH 1/2" COX PLYWOOD NAILED WITH 6d NAILS 6"OC S`DE EDGES, f2 "OC FIELD AND 3" Or- BOTTOM AND TOP EDGES, SCALE: ' /a" " -O" ALL THE INFORMATION ON TH18 PACE lS INTENDED TO BE CORRECT BUT MISTAKES CAN BE MADE AND IT 18 THE RESPON8181LITY OF THE CONTRACTOR TO VERIFY ALL INFORMATION PRIOR TO CONSTRUCTION. WE WILL BE AVAILABLE TO HELP RESOLVE ANY PROBLEMS. ROOF FRAMING PLAN ! i i I ' ALWAYS REFER TO TRU88 ENGINEERING BEFORE PORING LINTEE. t �Y C Tt ri T i WAVE PTV `WIO PLM AND " tT TO m to OO"PLIANGH WIC# 1�� OP T OTAMMM MtWWA COM `1 J