HomeMy WebLinkAbout5347 8TH ST SPEOIFICtiil0NS for Police Station & Court Room Addi4?.cn to The Zephyrhills Municipal building FCOT hG: bhall be 10" X 214" - j,000 PSI concrete -with four #5 reinforcing bare - continuous. F UNDAT i0N x L'hall be 8" X 12" X 16" Ocala ltlock and all cells filled with concrete - #L bars to be placed vertical on 2: centers. FLOUR: -hall be k" - 3,000 PSI concrete, with 6" X 6" mesh #10 gage steel wire for reinforcement, blab will be poured over compacted fill using 6 Mil po]yethelene for vapor ,barrier. before placement of concrete slab all compacted fill will be treated for termite control. EXTERIOR WALLS: Shall be 8* X 8" X 16" Ocala block, ith Dor-O -Wall placed every other horizonal joint starting in second joint above floor. Joints will be raked Loth vertical and horizonl to match existing building All cores as shown on sheet 1 (General Notes) 1 & 2, shall be poured. U lintel blocks as per plan shall be filled with concrete With 2 "5 reinforcing tars continuous and joist anchors set. STRUCTURAL STEEL: Steel Joist shall be 18 S 8 (open web type) to conform with existing building. t' round rod bridging top and bottom as per plan. Joist shall be welded to existing steel and steel anchors shere supported by masonry walls. C �o� ROOF: Shall be 3' thick tongued and grooved roof deck Panels, with built -up white gravel roof. All sheet metal work to conform with existing building. DOORS EXTERIOR: Front door (South Wall) shall be double acting alumunum, panel to be 1 /1" safety glas Side door (West Wall) shall be the same, except single acting. INTERIOR WALLS: All partitions shall be 2" X 4" framing on 16" center with preasure treated plates. All interior masonry walls shall be furred with 1" x 2" preasure treated strips on 16" center. All interior walls shall be 1 /1," plywood paneling of • INTERIOR DOORS: Shall be hollow °ore, flush veneer to match interior paneling. OILING: Shall be Acoustical Tile, supported by suspension system. FINISH FLOOR: Shall be Commercial Carpeting over padding of 68 os. Super Chief -Flat Slab Commercial cushion or equivalent PAINTING: All painting, staining, etc, shall be applied where required over properly prepared surfaces. ELECTRICAL WORK: All electrical work, installing of wiring, 'boxes, snitches, receptacles, etc, shall be performed as per plan. All materials will conform to Underwriters Laboratory Standards. 2 of 6 Sheets Work shall conform to all applicable codes, laws, ordinances and regulations of all agencies braving jurisdiction, as well as requirements of Florida lower Corporation. PLUMBING: Shall be located and installed as per plan in accordance with local plumbing code. Material and equipment shall be standard products of a reputable manufacturer. Shower stall shall be ceramic tiled 6' high. HEATING AND AIR OCNDITIONING: Unit shall be a product of a reputable manufacturer, adequately large enough to efficiently heat and cool addition and re- modeled area. Duct work shall be installed approximately as per plan, to be of a size and design to effectively heat and cool area. 3 of 6 Sheets Monthly estimates will be made on or before the first day of each month by the Aailding Committee of the City Council and the Contractor. The Contractor will be paid 90% of the esti- mate. Final 10% will be paid when the project is accepted by the City Council. Each bid will be accompanied by a check in the amount of two hundred fifty dollars ($250.00) and per- formance bond. In lieu of a performance bond, the Contractor will be paid 80% of the estimates. Final 20% will be paid when project is accepted by the City Council. In the event the proposal is accepted by the City and the Contractor fails to enter into a contract, his check will be kept as liquidated damages. Contractor to specify the number of working days in which he will complete building. A working week constitutes 5 days. (Monday through Friday) NOTE: CHANGES IN FLANS 1. Doorways to be cut through wall to rest rooms from Court Room. 2. Partitions to be installed in Court Room to provide dividers between Court Room and Rest Room. j. Outside door to be provided by vault. 4. Door to be provided for between Council Chambers and Plat Room. 4 of 6 Sheets Alit CONDITIONING SPECIFICATIONS Dosign Conditions Summer Outside 9j .B . and 79 W.B • Inside 78 D.B. and 50% R.H. Winter Uutside 30 D.B. Inside 70 W.B. People Courtroom - k0 Offices and Jail Area - 25 Ventilation 10 CFM per person Lights as per plan. Air velocities - a not 8� �� in bran branch ducts of the supply air system and 500 FPM in the return air system. Air Conditioning Units Shall be unitary package heat pumps as manufactured by General Electric, Carrier, Fedders or Westinghouse or equivalent. All units to be rooftop mounted on pitch pans. :structural members supporting the pitch pans must span a sufficient number of joists or rafters to insure adequate support of the unit without endangering the building structure. where duct work passes through the rooftop suitable provisions must be made to insure weatherproofing. and or stL heaters and lateledpandrinstalled located in com- and be U. L. approved piiance with the National Electrical Code. Air Conditioning Units Required The courtroom shall be conditioned by a rooftop mounted unit and one rooftop mounted unit for the office and jail area. 5 of 6 Sheets Air Distribution System Ducts may be 1" thick fiberglass, class II., minimum density of 2.5 lbs. per cubic foot. Ur, galvanized sheet metal insulated with 2" thick flexible insulation with vapor barrier - .75 lbs. per cubic foot density. All joints shall be scaled against vapor penetration. Opposed blade dampers shall be installed behind all supply grilles for balancing. Air Conditioning System Shall include all materials and labor including electri- cal wiring to have a complete operating system. Con - tractor shall balance system upon completion of install- ation. Contractor to service system including parts and labor free of charge for one year after final com- pletion and acceptance by the city. The compressor. are to have an additional Lt year warranty. Contractor shall guarantee system to maintain indoor temperatures and humidity at outdoor design conditions. 6 of 6 Sheets