FCOT hG: bhall be 10" X 214" - j,000 PSI concrete -with
four #5 reinforcing bare - continuous.
F UNDAT i0N x L'hall be 8" X 12" X 16" Ocala ltlock and all
cells filled with concrete - #L bars to be
placed vertical on 2: centers.
FLOUR: -hall be k" - 3,000 PSI concrete, with 6" X 6"
mesh #10 gage steel wire for reinforcement, blab
will be poured over compacted fill using 6 Mil
po]yethelene for vapor ,barrier. before placement
of concrete slab all compacted fill will be treated
for termite control.
EXTERIOR WALLS: Shall be 8* X 8" X 16" Ocala block,
ith Dor-O -Wall placed every other horizonal
joint starting in second joint above floor. Joints
will be raked Loth vertical and horizonl to match
existing building All cores as shown on sheet 1
(General Notes) 1 & 2, shall be poured. U lintel
blocks as per plan shall be filled with concrete
With 2 "5 reinforcing tars continuous and joist
anchors set.
STRUCTURAL STEEL: Steel Joist shall be 18 S 8 (open web
type) to conform with existing building. t' round
rod bridging top and bottom as per plan. Joist
shall be welded to existing steel and steel anchors
shere supported by masonry walls.
C �o�
ROOF: Shall be 3' thick tongued and grooved roof deck
Panels, with built -up white gravel roof. All sheet
metal work to conform with existing building.
DOORS EXTERIOR: Front door (South Wall) shall be double
acting alumunum, panel to be 1 /1" safety
glas Side door (West Wall) shall be
the same, except single acting.
INTERIOR WALLS: All partitions shall be 2" X 4" framing
on 16" center with preasure treated plates.
All interior masonry walls shall be furred
with 1" x 2" preasure treated strips on
16" center. All interior walls shall be
1 /1," plywood paneling of
•
INTERIOR DOORS: Shall be hollow °ore, flush veneer to
match interior paneling.
OILING: Shall be Acoustical Tile, supported by
suspension system.
FINISH FLOOR: Shall be Commercial Carpeting over padding of
68 os. Super Chief -Flat Slab Commercial
cushion or equivalent
PAINTING: All painting, staining, etc, shall be applied
where required over properly prepared surfaces.
ELECTRICAL WORK: All electrical work, installing of wiring,
'boxes, snitches, receptacles, etc, shall be performed
as per plan. All materials will conform to Underwriters
Laboratory Standards.
2 of 6 Sheets
Work shall conform to all applicable codes, laws,
ordinances and regulations of all agencies braving
jurisdiction, as well as requirements of Florida
lower Corporation.
PLUMBING: Shall be located and installed as per plan in
accordance with local plumbing code. Material
and equipment shall be standard products of a
reputable manufacturer. Shower stall shall be
ceramic tiled 6' high.
HEATING AND AIR OCNDITIONING: Unit shall be a product of
a reputable manufacturer, adequately large enough
to efficiently heat and cool addition and re-
modeled area. Duct work shall be installed
approximately as per plan, to be of a size and
design to effectively heat and cool area.
3 of 6 Sheets
Monthly estimates will be made on or before the first day of
each month by the Aailding Committee of the City Council and
the Contractor. The Contractor will be paid 90% of the esti-
mate. Final 10% will be paid when the project is accepted
by the City Council. Each bid will be accompanied by a check
in the amount of two hundred fifty dollars ($250.00) and per-
formance bond. In lieu of a performance bond, the Contractor
will be paid 80% of the estimates. Final 20% will be paid when
project is accepted by the City Council. In the event the
proposal is accepted by the City and the Contractor fails to
enter into a contract, his check will be kept as liquidated
damages. Contractor to specify the number of working days in
which he will complete building. A working week constitutes
5 days. (Monday through Friday)
NOTE: CHANGES IN FLANS
1. Doorways to be cut through wall to rest rooms from
Court Room.
2. Partitions to be installed in Court Room to provide dividers
between Court Room and Rest Room.
j. Outside door to be provided by vault.
4. Door to be provided for between Council Chambers and Plat Room.
4 of 6 Sheets
Alit CONDITIONING SPECIFICATIONS
Dosign Conditions
Summer Outside 9j .B . and 79 W.B •
Inside 78 D.B. and 50% R.H.
Winter Uutside 30 D.B.
Inside 70 W.B.
People Courtroom - k0
Offices and Jail Area - 25
Ventilation 10 CFM per person
Lights as per plan.
Air velocities - a not 8� �� in bran branch ducts
of the supply air system and 500 FPM
in the return air system.
Air Conditioning Units
Shall be unitary package heat pumps as manufactured by
General Electric, Carrier, Fedders or Westinghouse or
equivalent. All units to be rooftop mounted on pitch
pans. :structural members supporting the pitch pans
must span a sufficient number of joists or rafters
to insure adequate support of the unit without endangering
the building structure. where duct work passes through
the rooftop suitable provisions must be made to insure
weatherproofing.
and or stL heaters and lateledpandrinstalled located
in com-
and be U. L. approved
piiance with the National Electrical Code.
Air Conditioning Units Required
The courtroom shall be conditioned by a rooftop
mounted unit and one rooftop mounted unit for the office
and jail area.
5 of 6 Sheets
Air Distribution System
Ducts may be 1" thick fiberglass, class II., minimum
density of 2.5 lbs. per cubic foot.
Ur, galvanized sheet metal insulated with 2" thick
flexible insulation with vapor barrier - .75 lbs.
per cubic foot density.
All joints shall be scaled against vapor penetration.
Opposed blade dampers shall be installed behind all supply
grilles for balancing.
Air Conditioning System
Shall include all materials and labor including electri-
cal wiring to have a complete operating system. Con -
tractor shall balance system upon completion of install-
ation. Contractor to service system including parts
and labor free of charge for one year after final com-
pletion and acceptance by the city. The compressor.
are to have an additional Lt year warranty.
Contractor shall guarantee system to maintain indoor
temperatures and humidity at outdoor design conditions.
6 of 6 Sheets