Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
10-11243
CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780 -0020 11243 BUILDING PERMIT Permit Number: 11243 Address: 38705 LANSING AVE LOT 110 Permit Type: ADDITION /ALTERATION ZEPHYRHILLS, FL. Class of Work: 434 - ADD /ALT RESIDENTIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: SLEEPY HOLLOW MHSUB DIV Est. Value: Parcel Number: 02- 26 -21- 0260- 00000 -1100 Improv. Cost: 900.00 Date Issued: 12/01/2010 Name: CRAIG, HOBART Total Fees: 60.00 Address: 38705 LANSING AVE Amount Paid: 60.00 ZEPHYRHILLS, FL. 33542 Date Paid: 12/01/2010 Phone: (813)780 -2413 Work Desc: REPLACING 9 WINDOWS • •TYN :UIL.! .1.11 1 1 0 -95 //O 6 •• .. -•� .. 11: I . 1IF • FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE -METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE -SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to any one of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site f) plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." /� CONTRACTOR SIGNAT A RE PERMIT OFFI 'R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER . ...;cialy-,.. .0s -�r- -- City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: 0 ra 11-ixbtr- Date Received: //- Site: 3 D r3 44-,td /r( / Permit Type: (c r 9 (dd% D/o x Approved wino comments: ❑ Approved w /the below comments: Denied w /the below comments: ❑ i\c) S{Q This comment sheet shall be kept with the permit and /or plans. r Kalvin Swi er — xaminer Date Contractor and/or Homeownd (Required when comments are present) 813 -780 -0020 City of Zephyrhills Permit Application Fax -813- 780 -0021 Building Department ; �'2(.( .J 1 Date Received �� / a Phone Contact for Permittin / — Owner's Name C� ✓ ' //d '. / lam; Owner Phone Number �rJ�J ><S) Owner's Address L ' ? OS // /4 , A}- `" . Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS S ? = 1, / /cc/Gt A `/✓,`'.- Z///Y/'/- LOT # //C SUBDIVISION PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD /ALT 1 1 SIGN n 1 1 DEMOLISH INSTALL REPAIR PROPOSED USE En SFR 1 1 COMM ( I OTHER I I TYPE OF CONSTRUCTION I I BLOCK n FRAME I I STEEL I 1 1 I DESCRIPTION OF WORK /1 " C /' `, Ui v BUILDING SIZE SQ FOOTAGE HEIGHT r.4= UILDING $ 9,0 � J�) VALUATION OF TOTAL CONSTRUCTION 1 ELECTRICAL $ C/V AMP SERVICE 1 1 PROGRESS ENERGY I W.R.E.C. I 'PLUMBING $ 1 (MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION 1 (GAS I 1 ROOFING n SPECIALTY 1 1 OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA 1 (YES NO r c tUILDER E °I COMPANY IGNATUR J REGISTERED Y/ N I FEE CURREb I Y/ N Address License # ELECTRICIAN COMPANY SIGNATURE REGISTERED I Y/ N 1 FEE CURREh I Y/ N I Address 1 License # PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N . 1 FEE CURRE1 I Y/ N Address License # I MECHANICAL COMPANY SIGNATURE REGISTERED 1 Y/ N FEE CURRE N I Y/ N I Address License # I OTHER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURREh 1 Y/ N 1 Address License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R -O -W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Work Permit for subdivisions /large projects COMMERCIAL Attach (3) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R -O -W Permit for new construction. Minimum ten (10) working days after submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. * ** * PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner & Contractor sign back of application, notarized If over $2500, a Notice of Commencement is required. (A/C upgrades over $7500) ** Agent (for the contractor) or Power of Attorney (for the owner) would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs if shingles Sewers Service Upgrades NC Fences (Plot/Survey /Footage) Driveways -Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division— Licensing Section at 727 -847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT /UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89 -07 and 90 -07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water /Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law — Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner ", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S /OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection - Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District - Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers - Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services /Environmental Health Unit - Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency- Asbestos abatement. Federal Aviation Authority- Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone "V" unless expressly permitted. If the fill material is to be used in Flood Zone "A ", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. f FLORIDA JURAT (F.S. 117.03) J 1-0 4/ O WNER OR AGENT 4- 6*�/,- -Avll Gr./ CONTRACT( ' // / ' Subscribed and swom to (or affirmed) before me this Subscribed cribed a sworn too a before me this /( - z3 -iv by /�r lr/„ ��H/G r ' I s - z3 - (6 ) b /AO o� A,T /4/. (�P Who is/are personally known to me or has/have produced Who is /are erson known to me or has /have produced as identification. C.i (e/A-5,2 as identification. } Notary Public - `— Notary Public fission DD .z JACQUELINE BOGES . Decembe 2010 commission-No. Corn i . _'��• T� nsu 1 , omm - • i ;, : _ • ' • . ■ '• ` n B onded Troy - • `;;; 4- V a- Expires December 12, 2010 ,e B^ndod Thn T, r Insurance mu A35.7019 Name of Notary typed, printed or stamped Name of Notary typed, printed or starr�pe - DISCLOSURE STATEMENT .FOR OWNER CITY OF .ZEPBYREIZS.S BUILDING DEPARTMENT . Z //, /4 �. - /Z4' G7 /f'A11G: have read and fully understand and • agree to the provisions of this instrument. The undersigned .states and affirms that he or. she is desirous of constructing, . .renovating, adding to or reroofing his or her own domicile, that.he or she actually occupies, or will occupy bY' said domici:le,'and same is not for • rent, lease or sale.' That he or she vi-, comply with the following conditions: 1. That the owner and.he or she alone shall act as the builder for all phases of construction. 2. That the owner will comply with all provisions of the City of Zephyri'i ordinances and codes pertinent to the _building. • 3. That in the event various phases of construction are subcontracted, he will - engage only - properly licensed subcontractors and will personally.supe vise such work. '4. That in the event the Building Inspector s}1 require corrections to be made, the owner will assume full responsibility -to insure they are made, and upon Completion will ral1 for a rein- cti.on before proceeding with the building. 5. That the owner sha11 assume full responsibility for the construction and will not expect_ supervision of his work from the City, .of Zephyrhills Building Department. . 6. That prior to f'171=1 inspection any additional fees, including reinspection fees, must be paid in full. A written request from this office sha 1 1 • constitute an official notice to pay additional fees- _ 7. That the owner s 1,a11 comply with all City, State and Federal laws in regard to . social security, workman's compsation; lien laws, etc., where applicable. 8. That the owner shall comply en with all the safety codes issued by the Florida Industrial Commission. - 9. State law requires construction to be done by .licensed contractors. You have . applied for a permit under an exemption to that law. The exemption allows • . 'you, as the owner of your property, to•act as your own contractor with certain . restrictions even though you do not have a license. You must provide direct onsite supervision of the construction yourself. You may build or improve a one- family or two - family residence or a farm outbuilding. You may also build or improve a commercial. building, provided your costs do not exceed $25,000. The building or must be for your own use or occupancy. It may not be built or substantially improved for sale or lease.. If ,you seIl or lease a building you have built or substantially improved yourself within. 1 year after the construction is complete, the law will presume that you built or •• substantially improved•if'for sale or lease, which is a violation of this • exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building. It is your responsibility to . . make sure that people employed by you have licenses required by state law and • by county or municipal licensing ordinances. You may not delegate the - responsibility for supervising' work to a. licensed contractor who is not licensed to perform the work being done. Any .person . working on your building who is not licensed must work under•your direct supervision and must be . employed by you, which means that you must. deduct F.I. C.A. and withholding . and provide workers' compenssation for that employee, all as prescribed-by law. Your construction must comply with all applicable laws, ordinances, buil�Hng codes, and zoning regulations. . OWr1E12• s • s =r amrnzF �� , Z^i 01,.;; DATE //- / ,3 i a . ADDRESS .'P: n S' �ii.c'2 N r.. ,A .,i' L & T 1 // 0 • PHONE (,P /2.) ?..P0 •- -Z fr/ : T' • WITNESS - • R W R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry P.O. Box 230 Valrico. FL 33595 Phone 813.659.9197 Facsimile 813.754.9989 Florida Board of Professional Engineers Certificate of Authorization No. 9813 Product Evaluation Report Report No.: FL 6163.1 Rl Date: December 16. 2008 Product Category: Windows 11 Product sub - category: Single Hung ` PHYR4-liLL.S >i_ANS EXAMINE Product Name: 2100 Series - Model 2111 Extruded Vinyl Single Hung Window "Non Impact" Manufacturer: Silverline Building Products Corporation One Silverline Drive North Brunswick, NJ 08902 Phone — 732.435.1000 Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. (System ID # 1998) for Silverline Building Products based on Rule Chapter No. 9B- 72.070, Method 1 d of the State of Florida Product Approval, Department of Community Affairs - Florida Building Commission. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involve in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Florida Building Code (2007 Edition). See Drawing No.: FL 6163.1 prepared by R W Building Consultants, Inc. and signed and sealed by Lyndon F. Schmidt, P.E. (FL # 43409) for specific use parameters. Lyndon F. Schmidt, P.E. FL No. 43409 December 16, 2008 PF 907 Sheet 1 of 3 Limitations 1. This product has been evaluated and is in compliance with the 2007 Florida Building Code structural requirements excluding the "High Velocity Hurricane Zone ". 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection, this product is required to be protected with an impact resistant covering that complies with Section 1609.1.2 of the Florida Building Code. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL- 6163.1 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL- 6163.1 for size and design pressure limitations. Lyndon F. Schmidt, P.E. FL No. 43409 December 16, 2008 PF 907 Sheet 2 of 3 Supporting Documents A Drawing 1. Drawing No. FL 6163.1 prepared by R W Building Consultants, Inc. (Florida Board of Professional Engineers Certificate of Authorization No. 9813) signed and sealed by Lyndon F. Schmidt, P.E. B Tests Performed 1. Testing per AAMA/WDMA /CSA 101/1.S.2/A440 -05 as performed by Architectural Testing, Inc. and reported in test report number 73077.01 - 109 -47. signed by Michael D. Stremmel, P.E. 2. Testing per AAMA /WDMA /CSA 101/1.S.2/A440 -05 as performed by Architectural Testing Inc. and reported in test report number 74450.01 - 109 -47, signed by Michael D. Stremmel P.E. 3. Testing per AAMA /WDMA /CSA 101/I.S.2/A440 -05 as performed by Architectural Testing Inc. and reported in test report number 64764.01- 109 -47, signed by Michael D. Stremmel P.E. C Calculations 1. Product anchoring is in accordance with manufacturer's published recommendations as substantiated by tested specimens reported in test report numbers 01- 44453.01, 74450.01- 109-47 and 64764.01 - 109 -47. 2. Buck anchor analysis for loading conditions, prepared, signed and sealed by Lyndon F. Schmidt, P.E. D Other 1. Certificate of Participation issued by National Accreditation & Management Institute, Inc., certifying that Silverline Building Products is manufacturing products within a quality assurance program that complies with ISO /IEC 17020 and Guide 53. Lyndon F. Schmidt, P.E. FL No. 43409 December 16, 2008 YF 907 Sheet 3 of 3 ��y ' Ni S1NV11 PNiol,na 'M'!! ®OOL co � N 3'd 1P: 'A ..Pull SNOISIA32I by l / F S3 LON Tnl3N39 V S32l/LSS3tid A8 31.V0 'ON t j 7 NOIS30 WOUVATLI lealciAi ........3 the 'on 10 *WOW* i \ :.'•-•?' v ' Mj 1•..1..k .d M P+POC NN•W l.'18Y(35Sb NO DM o. CI n tcta asa s />:. •uwtd 2 ''';;1" i MSS - 1a 0 .1... ocz Hog 'O. '�j'' +NOOP W ONIH 371NIS • A 4 •-•1 3r I slnnnnsNOO 014101118 (1) E :/e modes. qu•,unxq 131W014d - E ... o 00 c 0 2 1 a . C7 2 0 X ` p N 2 0 0 ( 04- h , k ) n § lV zit b 1e, x x X i . a�a 1r1 Y2: 17v�L3AO'xvw.4107d-- - -_ - -- $ — 1MJ6H 39NV14 17VLl3A0'xVIN,09'£L — 4 1 ,,, 2 . n z x x x S 4 2 i �j a LL • m O it: imx. 7, 1 t ... i ; r >, CNI 0 gt 'i ii ; 1 0 W ..a ___ 1 W 8 m IgIf Lam W W 0 E $.— i 1 tol te) M ; il 1 . c c 5 fl 2 1 CV xi 7 vj l -ii .a.a 7QM TAJOISJEk 01 - 106 rokAsaNca v , d a;o+d - V4a OMI SSNwi,ner400 .NI., Me 'M'b 600E 0 e0•{► 'oN '3'd 'lpM OS '! r•rJ.h SNOLL03S SS0210 SNOISIA321 L'/ �.s �7 lV1NOZINOH 1V011213A AB 31V0 ON o — I Eri Pi eIOa ON u.N.:YOV10v JO •S.OUN,•O :A 210 Mid O E o 'o uwb1eu3 10.01.....d +• P. 0ou01! ts Le le'aCOY IY :•ON .d.4d I IO N w v u ses ..wn ocz ..a 'o d �r MOONIM JN(1H 31 NIS L i '31 . s.uw flSNOO ONIO'pfl9 U7 �+ AI pu.dud qu..un.oO :1Of10olld b a X ac O_ I'du) 'aw3 E 0 'N101,3 w e Z W 0 e 0 0 0 0 0 0 Iv • , „ r W (�' ° N Ill UC O O Awl —111; vd O ,, co i 111,.._ _,, _E_ , ,v ;-, L , : , 1 m _Le_ iiii . .: . Lu . a " i'--0 © ° 00000000 X w. '- _ a < .toclw O Y w W z N VIP z = a 0 w a 0 z, = o J - ) ,. w 'NI "' a 01 I ! T e W „It/ a f z a a 0 O f °C o z .a I1 U 0 ? . W • e i` e N 8 X " i ' I T % kn $ o! 6 O > N 8 m O 0 ® e M N CK 0 NN ©p 0 I�� - e zd clip , iiii 0 r ., • 1 , II Qp � w )110. � � e � i OHI SJ,NVL nSHOO oNIO Ifle M b 90DZ �y g o�£r ' b '3'd 1PIWws •d uor ,(1 SNOISIh32! L �L �`7� � • 3Proad �P0 )i0fl �8 3IV0 'ON 60 11 I £l ee 'eN Lee uiN.NV bawl e0 \ f/1 M *..w16.3 leeele.yO,d to rtOOe OPltelt l9W3SSV b0 11lYd Ch �- --I o L81.8'698'£le :'°N ..toed \ Z g MI cea££ - 1.4 OOw.n OCT •..e •o MOONIM ONfH I7 NIS 'ONI 'S±NV11f1SNO0 ONI011fle [!% a 1 6 :•(8 puodud .lu.u ^��a 11onaoad \ 1 1 1 1 0 Z z rc u ( O = to 4 c V lP 3? 2 =f W • 1 1 1 3m E mo N U U p VCp- m z it 0 V cX.l 3 Zz u =� 33 w =Jt o ZU. E 0 0 U E O .4< t a 1 2°E °pJ O ; O U s a C ZZZ 2 U ° m pJ E N N w 11 flfl 5 •� E aJ I_ xvw „v „e xvw „v —{ I C N ° -O ° co N 2 E E• uu 0 0 � >. =' 0 V0 �J0'o — . ..:. ., ooaEo ,r-- ia 13 E A g ..,-- — . . . EE o .: -0 . °mEE 0 o w z ° o 9, Nw' oa -- mwU c D . o o Q m o ..= u . d ti O 2 ° O ° N ° m Z Z Z- N N Q1 U 9 LT Q° U O C eg a s W C H c 2° t g V f 0 1 °m E m y Ft ce Z w V • O V i- P 0 d C ° ° E C ti U.nU o 9,U WPoW '6MP•S-T'E9T9 \E9T9- 13 \s6u`MeJa Damn .a \106Jd\pp0T - Tn6 (OM\slar1OA 1')a(0u\slla(nu - V114 DNI e1NV1ln6NOS ONla'llne 'M'b BODE orrr 'oN '3'd 1pI rn1o5 '4 00PO4 SNOISV\32! is aL S1N3NOdW00 3' 71V130 A9 31VO ON co 7 ONIZV70 S7V1931VW 30 1119 L66 'eN u zy ryr eyi /O pion Ii�.J ....“(61.13 loua M ..• d ao woos 0 14 ,0 14 : A Ve14 1BW3SSV NO 1HVd o, 1= 0 - - tc L61.6'646'f LG ='oN 00 e4d Z S6SCC 4 0 .1 , 1 0 A O£Z ree • o•d j . MOONIM ONfIH 37ONIS 3 - 0141 •SLNVnnSNOO ONIO1Ine (L2 i :4 p...1....,, nuownaoo :10fOOMd i ° m c „9E'0 „66'0 o u i > g 5 d h e C d o O w 0 w TT L 'o gyz Z U Z w. I ao a h a p1 „ d m A 1I o U U 0 e $ ZL'0 �I I w I m ® a0 W t P 9E' y o r110 it L ec o 13 p C7O j E N c� E m E gw d g + ° a 0 0 Q6O U �_ Y o 7 m a o p n b i ..6£Y �'-i_j W - . v ° n L . 6/ ,91 I d 24;7— > N w ..1 0'0 L j Z 0 0 d M000000000 - n. o_ o_ a a. o _ w N l-'y' y 0 0 Z O I o I W t z _ 3 3 O 3 o mz I I o m fl--1 ,A91' I I n o _ OZ sc O mce a 3 � p r--,,ecrz--- 3 —z :Lc a a Q Z u Q a . 61'I a ^ -_ F � . � 30 ° ns' T __ h O - - ' " 3N Oi. _� O f rOe�L - - 0 I I ,�, c ° 6e o3�3 _,YoN „' .,U Z Oe U S — ` >z J J .6 Z�= 1n Q }lI I d i Z cc u_ =n ° < r � J CO J �_ O O [1,1=' i w e” � n 7 x a U D < oe Z p ac a W w Zw,a U O d 0 pLL�l9 N 0 � U wZ 1 °° Z ��i , � o$ o wc e � ° d d �? a` — k Z .- '8,,> d p o ry L.2 m P o< .£9'0 -. 1 „18 L NK.N _. c d <� z Z Z ocLL 0m ] in a O Z m ao m c O3 O 8 g wW zzo u,IvN w C.._.o awe p V U LL <O Z_Z ww a , � ` 5 " - - 0 w VVE as 4 Z� t a G J� a U o _ c) .6 w W w» O "? 0 i-,7, O p -- a .E l a �{ l6'0 1-- ,,CO �,rpo�8o— X �� Z= = = 2NO on_ Nmp u-'' c° I tI I w U U V U V U U U U x a p p w < ui a gg a a a f x U ri, P . a w_ o = � E pn>.a aidiaeel dG' ,Fi cLV(gg,gO � a�0M � � a el 3 w ° F 1 °° U 2 E0 o W oo O00 W� wwwQ _'� o<� ° � �[ Z Z 1%, w O 1 V . e rn u o o 0 o oe ee a< o 666 ,' ' � i e 0 0 = cc ?Z " 'U z ocr;, 0 0>U ° m O fc h �ac�wx OwUG Z ul ul � x ' °O O x �p m O-� 1 N 0 oww ! � o ss µ t Li1, N M Y V n m P O- N M ' h a I� m p (�, R Y n m p W W ./ C _ _ - P N N N N N N N N N t7 I _ w o - y . .�'0 - .a - • �O L - IaOOw ' 1.\s&uwMeln •CMN •Vnad\mnr - rna fn,.,lslanlnu nafn,a\oiafn■ - ...0 R W R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry P.O. Box 230 Valrico_ FL 33595 Phone 813.659.9197 Facsimile 813.754.9989 Florida Board of Professional Engineers Certificate of Authorization No. 9813 Product Evaluation Report t ip. ... ... Report No.: FL 61632 R1 Date: December 16, 2008 Product Category: Windows ti 1E01 DATE__- Product sub- category: Single Hung r,}TY OF ZEPHYR ILLS Product Name: Series 2100 -Model 2111 -'i \NS %'EXAMINE ... -__ ..._ Extruded Vinyl Single Hung Window "Non Impact" Manufacturer: Silverline Building Products Corporation One Silverline Drive North Brunswick, NJ 08902 Phone — 732.435.1000 Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. (System ID # 1998) for Silverline Building Products based on Rule Chapter No. 9B- 72.070, Method 1 d of the State of Florida Product Approval, Department of Community Affairs- Florida Building Commission. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or "n any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Florl Building Code (2007 Edition. See Drawing No.: 6163.2 prepared by R W Building Consultants, Inc. and signed and sealed by Lyndon F. Schmidt, P.E. (FL # 43409) for specific use parameters. Lyndon F. Schmidt, P.E. FL No.43409 December 16, 2008 PF 907 Sheet 1 of 3 Limitations 1. This product has been evaluated and is in compliance with the 2007 Florida Building Code (FBC) structural requirements including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in the "HVHZ ", this product is required to be protected with an impact resistant covering that complies with Section 1626 of the Florida Building Code. 4. When used in areas outside of the "HVHZ" requiring wind borne debris protection, this product is required to be protected with an impact resistant covering that complies with Section 1609.1.2 of the Florida Building Code. 5. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. Increase anchor length to account for any sheathing or wall covering. 6. Site conditions that deviate from the details of drawing FL 6163.2 require further engineering analysis by a licensed engineer or registered architect. 7. This product meets water infiltration requirements for "HVHZ ". 8. See drawing FL 6163.2 for size and design pressure limitations. Lyndon F. Schmidt, P.E. FL No. 43409 December 16, 2008 PF 907 Sheet 2 of 3 Plan Review Windows & Doors 1) Need manufacturing installation specifications. 2) Must meet sections R308 and R612 of the 2007 F.B.C. 3) If windows are to be installed inside the historical district, they will need to be approved by the historical committee. 4) No other work shall be permitted (framing, plumbing, and mechanical) unless otherwise specified. 5) This is for replacement (glass for glass) only. If you wish to change from screen or vinyl windows to glass, then additional information is required. . Pasco County Parcel: 02- 26 -21- 0260 - 00000 -1100 001 Page 1 of 1 I Data Current as Of: II Weekly Archive - Saturday, November 27, 2010 I Parcel ID I 02- 26 -21- 0260 - 00000 -1100 (Card: 001 of 001) I I Classification II 02 - Mobile Homes I Mailing Address Property Value CRAIG HOBART W Ag Land $ 38705 LANSING AVE LOT 110 Land $11,500 ZEPHYRHILLS FL 33542 -6351 Building $7,649 Physical Address Extra Features $225 38705 LANSING AVE ZEPHYRHILLS FL 33542 -6351 Market Value $19,374 Legal Description (First 4 Lines) Assessed (Non - School Amendment 1) $19,374 SLEEPY HOLLOW MOBILE ESTATES Taxable Value $19,374 RESIDENTIAL COOPERATIVE OR 4507 PG 292 (P) LOT 110 Land Detail (Card: 001 of 001) I Line II Use I,DescriptionII Zoning II Units II Type II Price II Condition II Value I 1 II 0100 II SFR II 00M2 II 1.00 II LT II$11,500.00II 1.00 II $11,500 I Additional Land Information I Acres II 0.08 II Tax Area II 30ZH II FEMA Code II -- IlResidential CodeII SHOPLP1 I Building Information - Use 02 - Mobile Home (Card: 001 of 001) Year Built 1970 Stories 1.0 Exterior Wall 1 Pre - Finished Metal Exterior Wall 2 None Roof Structure Flat Roof Cover Min Roof(Corr. or Sh M) Interior Wall 1 Plywood Panel Interior Wall 2 None Flooring 1 Cork or Vinyl Tile Flooring 2 Carpet Fuel Electric Heat Forced Air - Ducted A/C None Baths 1.0 I Line 11 Description II Sq. Feet 11 Repl. Cost New I 1 II BAS II 720 I $19,426 I 2 II FSA II 200 I $2,428 I Extra Features (Card: 001 of 001) I Line II Description I Year 11 Units 11 Value I 1 II DWC 1 1975 I 240 11 $225 I Sales History Previous Owner 1 SLEEPY HOLLOW MOBILE I Year II Month I Book /Page II Type II Amount 2006 II PL 05 I 6966 / 1534 11 11 $25,000 2000 10 1 4482 / 0710 11 WD 11 $0 I 1997 II 10 I 3818 / 1909 11 WD 11 so http: // appraiser. pascogov. com / search /parcel.aspx ?sec= 02 &twn= 26 &rng = &sbb= 0260 &b... 12/1/2010