Loading...
HomeMy WebLinkAbout10-11341 CITY OF ZEPHYRHILLS f 5335 - 8TH STREET (813)780 -0020 11341 FIRE STANDPIPES PERMIT Permit Number: 11341 Address: 7250 GALL BLVD Permit Type: FIRE HOOD SUPPRESSION SYS ZEPHYRHILLS, FL. Class of Work: FIRE -HOOD SUPPRESSION SYS Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 35- 25 -21- 0010 - 07200 -0000 Improv. Cost: 2,400.00 Date Issued: 12/21/2010 Name: CNL INCOME FUND IV LTD Total Fees: 130.00 Address: 1155 PERIMETER CENTER W #700 Amount Paid: 130.00 ATLANTA GA 30338 -5440 Date Paid: 12/21/2010 Phone: Work Desc: INSTALLATION SUPPRESSION SYSTEM -PAPA JOHN - . ` 011-1 1 - I --- . 1.11 - - I - V n 1.11 rte l�s € FIRE INSPECTION FEES 1 7 30.00 �(ec` A r - - , U O t_11-(1 � � e ressi k f , (2 Safe -Ina Chapter 633, Florida Statutes, authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees, and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of $100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." / C di 2 Irk C RACTO S N RE ATU - I •' IC R P R MIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT - Fire Marshal Office - 813- 780 -0041 = curDate > <curTime>Work Comp Associates Inc .Brian A Padgett PRODUCER THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO Work Comp Associates, Inc. RIGHTS UPON THE CERTIFICATE HOIDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND P OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. P.O. Box 33297 Palm Beach Gardens, FL 33420 -3297 USA COMPANIES AFFORDING COVERAGE COMPANY A BusinessFirst Insurance Company INSURED COMPANY Weeks Electric, Inc. B 23250 Singer Lane COMPANY Brooksville, FL 34601 -7702 C COMPANY D THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE USTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FCR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. CO TYPE OF INSURANCE POLICY NUMBER POLICY EFFECTIVE POLICY EXPIRATION UMITS LTR DATE (MM/DD/YY) DATE (MM/DD/TY) GENERAL UABILITY GENERAL AGGREGATE , COMMERCIAL GENERAL LIABIUTY PRODUCTS - COMP/OP AG e $ CLAIMS MADE D OCCUR PERSONAL & ADV INJURY •, OWNERS & CONTRACTORS PROT EACH OCCURRENCE $ FIRE DAMAGE (Any one fire) •, MED EXP (Any one person) $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ ANY AUTO ALL OWNED AUTOS BODILY INJURY $ SCHEDULED AUTOS (Per Person) HIRED AUTOS BODILY INJURY NON -OWNED AUTOS (Per Accident) $ PROPERTY DAMAGE $ GARAGE UABIUTY AUTO ONLY - EA ACCIDENT $ ANY AUTO OTHER THAN AUTO ONLY: EACH ACCIDENT AGGREGATE $ EXCESS LIABIUTY EACH OCCURRENCE $ R UMBRELLA FORM AGGREGATE OTHER THAN UMBRELLA FORM $ WORKERS COMPENSATION AND XX I TU 1 o R A EMPLOYERS' UABIUTY 0521004310000 4/1/2010 4/1/2011 EL EACH ACCIDENT •, 1 00 000 THE PROPRIETOR/ INCL PARTNERS/ EXECUTIVE EL DISEASE - POLICY LIMIT 500 000 OFFICERS ARE: xp EXCL EL DISEASE -EA EMPLOYE: $ 100,000 OTHER DESCRIPTION OF OPERATIONSILOCAT1ONSNEHICLESISPECIAL ITEMS A 30 - day notice of cancellation applies for all reasons other than non - payment of premium. SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE City of Zephyrhills Building Dept. EXPIRATION DATE THEREOF, THE ISSUING COMPANY WILL ENDEAVOR TO MAIL 10 5335 Eighth Street DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO MAIL SUCH NOTICE SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY Zephyrhills, FL 33540 - 4312 KIND UPON THE COMPANY, ITS AGENTS OR REPRESENTATIVES. AUTHORIZED REPRESENTATIVE (, / i f ,i'r ; % • /— (BAP) :curDate > <curTime >Work Comp Associates Inc.Brian A Padgett IMPORTANT If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). DISCLAIMER The Certificate of Insurance on the reverse side of this form does not constitute a contract between the issuing insurer(s), authorized representative or producer, and the certificate holder, nor does it affirmatively or negatively amend, extend or alter the coverage afforded by the policies listed theron. . 11 �I 813 - 780-0020 city of Z imketimr, 1� I� 13- 780.0021 - Permit Application - Date Received ' I't%�iIL� i • ,• for :_ ,;,,w1N J WL:i 1 l ' Owner's Name . • V` i i � Owners Phone Number •1 1 1 •1 1—,—.-1 w Oners Addles 1 7 7.4R - V /11.Z... N /11.Z... Y /✓2 L/ i I Fee Simple Titleholder Name I • I Titleholder Phone Number I I I • I I I Fee SkrrplftllralrolderAddrsaaJ ( I semeieW do Lot * Job Address e� �1 Sub Division Parcel * 35 WG' I -A l' A/ 'v� 0o-il a - • .. , . , • • - ANNUAL • a Fudgaron Tent - Comm Exhaust Kitchen • • • • - I Hazardous Material (Tier II or RO Facility) ANNUAL IN Emergency Generator < 30 kw ill LP/Natural Ga-k aaWon • op Emergency Generator 3. 30 kw III LP/Natural Gas -4N UAL Sat. • • - Protection Maintenance - ANNUAL - Places of Aasembly,ANNUAL -11)ifillier ■ 0 0 0 Burn Roe Alemn 0 0 0 - Smolders • Clewing ■ 0 0 0 • Sprinkler System iMa#atlan . fir. 0 0 S p r Aim ai r stJNation _ - - T orch PoolingRar Kettle , Fire Pumps — - Eil_ Waste Tire Storage ANNUAL Pre Works , Remntabie A Plan- ANNUAL Vatuadon of Project • Rai Tanks , • ® s' Addrus r �u - a ®74 .dye s R.pisr.d [� Y / N F.. C"rwdt MUNI - Address * �2?.C. . Lktenaa 1 0 ; ; PUTAABEFt Company I Signature Reglewed Y N Fee Current I Y if N 1 Adldress I License * ( I • Rpetered I Y/ N j Fes arrant I Y/ N I Addr!ass St I I License LL OTHER Cornparty _ I Signature I Regia sm i I Y/ N. I No Current i Y/ N 1 Warps* . I , oirr . lay owner, 4 'Cdr<tderar aar± work over i30oo) If over > 2%0. a Melee t> . Supply -item t .e to of p • Now 10.14 cloys -for • ri s M d M: , . ' ` , vJ " parcel * - obtained from Property Tax Notion .0aIdrr0ov -�) 'NOTICE OF:DEED RESTRICTiONSIMPliaihdersigneci `understands .that 'this may besu eeod", raatrtctiens" which may be _more • restrictive 'thannOodiVreguiations. Thewndersigned .assumes responsibilitylmopmplianhelmith any :apps dd reed tUNL:IE tt 1 et*TRA 'TORS " CTOR:REBRONSIBIL;fT1ES: • *if - the owner - hattiftrethavontractor 'or contractors to undertake work, they may be required to be licensed in accordance with state and .local - regulations. if the contractor is not licensed as required by law, bob the owner and contractor may be cited - for a . misdemeanor violation under state law. lithe the owner or intended •contractor are uncertain 4810 what licensing •requirements may apply for the intended work, they are advised to contact the Pasco County Building Inipection Division- - Uoensing Section.at 727.847- 8009 Fie, if the owner has 'hired a contractor or contractors, he is advised to have the .contractor(s) sign portions of toes !contractor Block" of this application for which they wUl be responsible. If you, as the owner sign as the contactor, that may be an indicatlon that he is not properly •licensed and is ,not-entltled °to permitting :priv#eges in Pasco County, CONSTRUCTION .LIEN` LAW (Chapter718, Florida Statutes,:asamended): if valuation of work is $2,`500.00 or more, I certify that I, the applicant, have been provided with a copy of the 'Florida Construction Lien Law Protection Guide' prepared by•the Florida Department of Agrbwfture and Consumer Affairs. If the applicant is someone other than the 'miner, I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the 'owner' prior to commencement CONTRACTOR'S/OWNER'S •A11 1AW : I certify that all the information in this applIcation Is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permfttto do work and installation as indicated: 1 certify that no work or installation has commenced prior to issuance of a permit and -that all work will be performed to meet standards of all laws regulating construction, County and Cfty codes, :zoning regulations, and land development regulations In the J_i rtsdictbn. I also cello/ that I understand that the regulations of other . government agencies may apply•to the. Intended work, and that It is my responsibility to identify what actions I must take•to be in compliance. If I am the AGENT FORTHE OWNER, 1 promise In good faith to inferm the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be regUlred`fOr electrical work, plumbing, signs, wells, pools, air conditloning, gas, or other installations not spec!ically included in the application. A permit Issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shag Is$uanoe of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit Issued shall become Invalid unless the work authorized by such permit is commenced within six months of permit issuance, or If work authorized by the pennit is suspended or abandoned for a • _ • of sic (6) months the time the work is commenced. An extension may be mut in writing, from the Bulld • Official for a -period not • exceed the (90) considered and will demonstrate eawe o the a enalen. If work for nines (00 • ° ' days, job Is abandoned• WARNIN TQ I `1fQ�Mllt TO REC A NOT E ®, _ 'COMN NT MAY RESULT IN YOUR PAYIN Q - ; < TO • P { 4 4 : T©" a.., CONSULT as Ids. " as � ` Notaweil a • ' �S rs :��rAlfi I Notary public CommissionNo• Name or r hams NU. I or sisineed KWOOMMISSION4IMOTO FI•• Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Marshal Bus (813) 780 -0041 Kerry Barnett Fax (813) 780 -0044 E -mail: kbarnett@fire.zephyrhills.fl.us Plan Review #: 10 -154 Project: Hood Suppression Number of Pages: Packet December 20, 2010 I have received and reviewed the plans for the installation of a hood suppression system located at 7250 Gall Blvd and will allow the project to move forward. Please note that this review does not eliminate any further requirements as the project continues moving forward. By paying for permit, contractor acknowledges to comply with the items listed below. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. 1. K Class extinguisher shall be installed the immediate location. 2. Install a horn/strobe attached to the system that will activate if system goes off. 3. Gas valve shall shut down and electric under hood shall shut down. 4. Make up air shall shut down but exhaust remains on. 5. Ensure proper signage is installed with the pull station and K Class extinguisher. Inspections Required: 1. Acceptance Test (balloon test) KERRY B - ' NETT, FIRE MARSHAL ** *Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. • ZEPdYRHILLS FIRE DEPARTMENT 6907 Dairy Road, Zephyrhills, FL 33542 Fne Chief Keith Williams Bus (813)780 -0041 Fax (813)780 -0044 FIRE SERVICE USER FEES Occupancy No.: p � Plan No.: /9 / V Contractor: /moo / -5 S Business Na e: �'.,* ; Billing Address: //09 . , ?' i)� L.cd� a Business Address: OAS — 6 .0-1.l 'rare 1, \. fI 34-1 Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: _ PLAN REVIEW FEES INSPECTION FEES _ PERMIT FEE — FALSE ALARM FEE _ Site Plan N/C Annual N/C ` Sprinkler $50 — 1st Alarm N/C Multi - Family /Commercial .06 sf — 1st Re- inspection N/C Standpipes $50 _ 2nd Alarm N/C (Minimum Charge $25.00 _ 2nd Re- inspection $100 — Fire Pump $50 ,-- 3rd Alarm N/C ri Plan Revisions DBL — 3rd Re- inspection $250 (� Hoods s_! t — 4th Alarm $100 5500 4th Re-Inspection Fire Ala 5 50 — 5th Alarm $150 SPRINKLER SYSTEMS (Business closed until LP Gas $50 — 6th Alarm $200 0 - 25 Heads $50 violations corrected) _ Natural Gas $50 _ NON COMPLIANCE $150 26 plus Heads $100 — SPRINKLER SYSTEM Fuel Tanks - per tank $50 STANDPIPE SYSTEM — Hydro Undergrounds $45 — ergroun Sparklers $100 0 Per Riser $50 _ Hydrostatic Test $65 per system ..... Fire Works $500 FIRE PUMP _ Acceptance Test $45 per system — Camp Fire $25 0 Per Pump $100 _ Hydrant Flow $75 _ Controlled Burn $100 __ FIRE ALARM SYSTEM _ Hood /Duct $50 -- 0 - 25 Devices $50 _ FIRE ALARM SYSTEM — Place of Assembly $50 Annual 26 plus Devices $100 _ System Acceptance $50 Fire Protection $25 SUPPRESSION SYSTEMS _ Recall Acceptance $50 — Flammable Application $50 Annual — Wet $50 OTHER —, Waste Tire Storage $50 Annual _ Dry $50 — Fire Wall /Smoke Wall $15 per wall — Generator < KW $100 _ CO2 $50 _ LP Gas $25 per tank _ Generator >30 KW 150 Other Natural Gas $25 per system — Bio-Hazard Waste $100 Annual KITCHEN EXHAUST ( _ ` Fumigation Tenting $50 0 Hood /Ducts $50 ^ Tent 10'x10' or greater $15 per ten Torch Pot/Applied $50 ^ OTHER Fire Pump $45 Haz. Materials $100 Annual LP Installation per tank $50 Fire Suppression Fuel Tank Installation $50 _ System Acceptance (Per Tank) $50 Exhaust Hood /Duct $30 0 Natural Gas Installation $50 — Re- inspection DBL (Per System) (other than annual) 0 Spray Booth $50 Ei Inspection scheduled DBL and cancelled less than _ 24 hours Construction Insp. N/C _ Emergency Vehicle & $50 FALSE ALARM PLANS TOTAL 5 INSPECTION TOTX1 139 1 PERMIT TOTAIStYr TOTAL i GRAND TOTAL I /30 1 Comments Date: / Z U ie / Insg AieeZI r '1 J — `ill HERNANDO FIRE & SAFETY EQUIPMENT CO., INC. 4 1109 Ponce De Leon Boulevard I �W * Brooksville, Florida 34601 Phone: 352 796 - 4433 Fax: 352- 796 -5679 y , 1- 800 - 330 -6230 1 Ansul R -102 (UL300) liquid chemical fire suppression system. Installed per NFPA -17A, NFPA -96, state /local codes, and manufacturer's specifications. Gas valve, make -up air and any electrical sources under the hood are tied into the system for automatic shut down. Facility fire alarm (if installed) sounds with system activation. Remote manual pull station to be located per Florida Standard Mechanical Code, a minimum of 10 ft. and maximum of 20 ft. from the cooking equipment unless an alternate location is specifically approved by the mechanical official. Piping limitations and nozzle placement to be in accordance with Ansul R -102 design and installation manual. Submitted By: Hernando Fire & Safety Eqpt. Co., Inc. 1109 Ponce De Leon Blvd. Brooksville, F1. 34601 (800- 330 -6230) Florida State License # 43750500011988 Job Site: Papa John's 7250 Gall Blvd. Zephyrhills, FL. 33541 U; IMMJTr PLANS) LAVE BEEN !U' ZEPHYRHI S RE ARSHA 'S Date: ® er sviawer: • N9 To k 1 -. ' A - .1, A kp 3 --. ;I,1 .,1/4 c-c cv ;1 Q 3 M k Nd kk- L k) V 3 tw ---, Q Cf) t- -f.) ?cs,sN N' rls 1 '• C:$ NI (..) szo ckc \.- N ---- -..- , Lr, u, ,,. , -„, Q -..)( \--- .D v L1 b0 h . _____ _____i_ _____ k—az ›i • ulletiin by Tyco Fire Suppression & Building Products One Stanton Street Marinette, WI 54143 -2542 www.ansui.com Bulletin No. 5653 DATE: April 29, 2010 TO: All Authorized ANSUL R -102 System Distributors and OEMS's FROM: Product Management — Restaurant Systems SUBJECT: Non -UL- Listed Fire Protection for Conveyor Pizza Ovens The UL300 Standard: Fire Testing of Fire Extinguishing System for Protection of Commercial Cooking Equipment does not currently address a test protocol for conveyor pizza oven protection. However, in many jurisdictions, the Authority Having Jurisdiction has required fire protection for conveyor pizza ovens. In the past, appliances not addressed in the UL300 test standard have been protected by following listed protection options for other appliances with similar operating characteristics. Generally, these appliances presented a more severe hazard than the appliance in question. In the case of conveyor pizza ovens, chain broiler protection was utilized. To confirm recommended protection, we recently conducted a conveyor pizza oven fire test following the chain broiler test protocol outlined in UL 300, substituting fatty hamburgers with a grease coated pizza crust, to emulate the cooking process used by conveyor pizza ovens. Prior recommendations for conveyor pizza ovens larger than the two 1N horizontal nozzle limitations for a chain broiler, suggested using four 1N nozzles, each positioned at the end corners and aimed diagonally across the chain within the oven. Based on the actual fire testing, we now recommend two 245 nozzles per conveyor: one nozzle is positioned at the inlet and one nozzle is positioned at the outlet of the conveyor pizza oven on the same side of the oven and aimed at the opposite corners. Utilizing two 245 nozzles as recommended is suitable protection for conveyors larger than the limitations for a chain broiler but not exceeding 38 in.(96.5 cm) wide x 70 in (177.8 cm) long. If you should have questions pertaining to this bulletin, please contact your U.S. District Manager or International Area Manager; or call Technical Services as noted below. Main Telephone Numbers: 1- 800 -862 -6785 or 1 -715- 735 -7415 Customer Services: Press 2 • Technical Services: Press 4 • Training Services: Press 6 • Quality Assurance: Press 8 Literature Fax Orders: 1- 800 - 543 -9822 or 1-715-732-3474 SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-1 3 -1 -07 REV.7 SYSTEM DESIGN GENERAL INFORMATION The ANSUL R -102 Restaurant Fire Suppression System may be 1. Nozzles must be located 2 -8 in. (5 -20 cm) into the center of the used on a number of different types of restaurant cooking appii- duct opening, discharging up. See Figure 1. ances and hood and duct configurations. The design information listed in this section deals with the limitations and parameters of this pre - engineered system. Those individuals responsible for the design of the R -102 system must be trained and hold a current ANSUL certificate in an R -102 training program. 111141111 The R -102 and the PIRANHA systems use compatible agents and components, therefore, they may be used together for cooking appliance, hood, and duct protection. The primary ANSUL AUTOMAN Release can be either an R -102 or a PIRANHA ANSUL AUTOMAN Release and can actuate up to two additional R -102 or PIRANHA Regulated Actuators. In systems utilizing a � 101 remote release, any combination of the maximum number of regulated actuators can be used. 2 — e IN (5 — 20 cm) t • Both systems must actuate simultaneously. • Each system must be designed and installed per its appropri- FIGURE 1 ate manual. 000173 • Adjacent appliances requiring protection must be protected 2. In installations where a UL listed damper assembly is with the same type of system, either R -102 or PIRANHA, employed, the duct nozzle can be installed beyond the 8 in. unless the center -to- center spacing between the adjacent (20 cm) maximum, to a point just beyond the damper assem- R -102 and PIRANHA nozzles is no less than 36 inches. bly that will not interfere with the damper. Exceeding the maxi- • When appliances are protected with R -102 nozzles, the hood mum of 8 in. (20 cm) in this way will not void the UL listing of and connecting duct above those appliances cannot be pro- the system. tected with PIRANHA nozzles. 3. Previously listed 3 flow number and 5 flow number duct pro- • Mixing systems in a common plenum is not allowed. tection detailed in earlier published manual, Part No. 418087 - One of the key elements for restaurant fire protection is a correct 06, can also still by utilized. system design. This section is divided into ten sub - sections: Noz- DUCT SIZES UP TO 50 IN. (127 cm) zle Placement Requirements, Tank Quantity Requirements, Actu- PERIMETER/ 16 IN. (41 cm) DIAMETER ation and Expellant Gas Line Requirements, Distribution Piping Requirements, Detection System Requirements, Manual Pull Sta- • One 1W nozzle (Part No. 419336) = one flow number tion Requirements, Mechanical Gas Valve Requirements, Electri- 50 in. (127 cm) perimeter maximum cal Gas Valve Requirements, Electrical Switch Requirements, and Pressure Switch Requirements. Each of these sections must be • 16 in. (41 cm) diameter maximum completed before attempting any installation, System design sketches should be made of all aspects of design for reference DUCT SIZES UP TO 100 IN. (254 cm) during installation. PERIMETER/ 32 IN. (81.3 cm) DIAMETER NOZZLE PLACEMENT REQUIREMENTS • One 2W Nozzle (Part No. 419337) = two flow numbers This section gives guidelines for nozzle type, positioning, and • 100 in. (254 cm) perimeter maximum quantity for duct, plenum, and individual appliance protection. This • 32 in. (81.3 cm) diameter maximum section must be completed before determining tank quantity and The chart below shows the maximum rotection available from piping requirements. each duct nozzle. p Duct Protection — Single Nozzle Part 3.0 Gallon 1.5 Gallon All duct protection is UL listed without limitation of maximum duct Description No. System System length (unlimited length). This includes all varieties of ductworks 2W Nozzle 419337 Maximum Maximum both horizontal and vertical including ducts that run at angles to 100 in. (254 cm) 100 in. (254 cm) the horizontal and ducts with directional bends. Perimeter Perimeter The R -102 system uses different duct nozzles depending on the 1W Nozzle 419336 Maximum Maximum size of duct being protected. 50 in. (127 cm) 50 in. (127 cm) Perimeter Perimeter SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-5 4 -1 -06 REV. 4 \,_,/ Plenum Protection ► Option 2: The 1W nozzle must be placed perpendicular, 8 -12 in. The R -102 system uses the 1W Nozzle (Part No. 419336) or the (20 -30 cm) from the face of the filter and angled to the • 1N Nozzle (Part No. 419335) for plenum protection. The 1W noz- center of the filter. The nozzle tip must be within 2 in. zle tip is stamped with 1W and the 1N nozzle tip is stamped with ( cm) from the perpendicular center line of the filter. i N, indicating they are one -flow nozzles and must be counted as See Figure 8. one flow number each. When protecting a plenum chamber, the 12 IN. (90 cm) entire chamber must be protected regardless of filter length. MA liko\ XIMUM 4 IN. VERTICAL PROTECTION — GENERAL (10 cm) • One 1W nozzle will protect 4 linear feet (1.2 m) of plenum. The , / i 8 I N . (20 cm) maximum distance from the end of the hood to the first and last ° I� nozzle must be no more than 2 ft. (.6 m). After the first nozzle, any kb *`' additional nozzles must be positioned at a maximum of 4 ft. (1.2 m) NOZZLE TIP °• apart down the entire length of the plenum. The plenum width must MUST BE WITHI THIS AREA ► not exceed 4 ft. (1.2 rn). (The 1W nozzle can be used on single or au . V bank filter arrangements.) See Figure 6. , •ir' 2FT.(.6m) MAXIMUM -► FIGURE 8 000200 MAXIMUM 4 4FT.(1.2m) �� \4FT.(1.2m) 2 Fr (.6 m) MAXIMUM • MAXIMUM HORIZONTAL PROTECTION — OPTION 1 MAXIMUM i 1N NOZZLE — PART NO. 419335 — SINGLE BANK PROTECTION � �/ One 1 N nozzle will rotect 10 li r , p nea f linear (3.1 m) of single filter bank �/ plenum. The nozzle(s) must be mounted in the plenum, 2 to 4 in. 7 (5 to 10 cm) from the face of the filter, centered between the filter i height dimension, and aimed down the length. The nozzle must be ® % ,.� • positioned 0 -6 in. (0 -15 cm) from the end of the hood to the tip of the '" /�, I nozzle. See Figure 9. �. 2 - 4 IN. 10 FT (3.1 m) t FIGURE 6 (5 -10 cm) MAXIMUM 000,97 r ► When protecting plenums with the 1W nozzle, two options of cov- erage are available: ► Option 1: The 1W nozzle must be on the center line of the single 000201 40 or "V" bank filter and positioned within 1 -20 in. I (2.5 -51 cm) above the top edge of the filter. See Figure 7. \I 1 20 IN. (51 cm) FIGURE 9 MAXIMUM `` 000202 1 IN. (2.5 cm) MINIMUM :.::.::;. , 20 IN. (51 cm) i " 1 f MAXIMUM 1 IN. ( 2.5 cm MINIMUM FIGURE 7 000199 HERNANDO FIRE & SAFETY EQUIPMENT CO, INC. 1109 PONCE DE LEON BLVD. BROOKSVILLE, FL 34601 Phone: 352 - 796 -4433 1- 800 - 330 -6230 Fax: 352 - 796 -5679 hemandofiresafe@bellsouth.net City of Zephyrhills December 21, 2010 5335 8th Street Zephyrhills, FL 33541 Dear Sir or Madam: Raymond K. Ferguson, President of Hernando Fire & Safety Equipment Company, Inc., authorizes Curl Meyer to apply, sign and pick up building permits in the City of Zephyrhills from this date through December 20, 2011 State License # 43750500011988 Sincerely, 14aymk9k1 K. Ferguson, President The foregoing instr ment was sworn to and ubscri ed before me this o`I day of L7It'r . 20La_ by ,', 4 }5 �4f ant ,Lx) who is personally known to me or ( ) who has producdd " f as identification. NO Y PUBLI e- Celebrating over 25 Years of Fire Protection Services in the State of Florida And 18 years as an Authorized Ansul Fire Equipment Distributor a FRANCIS SPERLAZZA ► , MY COMMISSION # DD844782 EXPIRES: December 12, 2012 1400341OTARY FI. Nctry Dimol Anoc. Oa