HomeMy WebLinkAbout11-11533 CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(si3)�so-oo20 11533
� BUILDING PERMIT
Permit Number: 11533 Address: 38192 MEDICAL CENTER AV
Permit Type: RE-ROOF ZEPHYRHILLS, FL.
Class of Work: ROOF REPLACEMENT Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: CITY OF ZEPHYRHILLS
Est. Value: Parcel Number: 35-25-21-0070-00000-0053
Improv. Cost: 4,700.00
Date Issued: 2/22/2011 Name: MANOHAR, RAJNISH & PRIYA
Total Fees: 90.00 Address: 313 FERN CLIFF AVE
Amount Paid: 90.00 TEMPLE TERRACE FL 33617
Date Paid: 2/22/2011 Phone:
Work Desc: REROOF W/ TPO WHITE RUBBER
C� ,/
� `(/ "
T�'
G�
�� �
�
TAPE JOINTS ROOF INSP
FINAL tZ'L�"L�
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection
trips are necessary due to any one of the following reasons: a) wrong address b) condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d) work not ready for
inspection when called e) permit not posted on job site t) plans not at job site g) work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this couniy, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
The payment of inspection fees shall be made before any further permits will be issued to the person owning same
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your properly. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
^�y��� "�
CONTRACTOR SIGNATURE PERMIT OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
a�saso City ot Lephyrhills Nermit Appllcation rax
Building Department ,,,/� j/s"'2 7,.
f�f" l J
Date Recefved - � Phone Contact for Permittin - -� ��
Owner's Name � D� I.S h I^/l � v1 c(/t Gi ✓ Owner Phone Number
Owner's Address � 1 3 �� v+� C(� fi{ �✓.2 ��� � r� vf `�' Owner Phone Number
Fee Simpie Titleholder Name �— Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS I/ L �t C' L� V �tv� LOT # �
SUBDIVISION , PARCEL ID# ��ZS - (jU�O "OUi�b - pp ` - �j
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED B New coNSTR e ADD/ALT 0 SIGN Q Q DEMOLISH
INSTALL REPAIR
PROPOSED USE Q SFR Q COMM Q OTHER
TYPE OF CONSTRUCTION Q BLOCK Q FRAME Q STEEL Q
DESCRIPTION OF WORK �-t= U � O,/� N� �} , - � - '1,� �� ~ 1 �(,� �„�►� � � �h (AZy �e ",� � H` / y
BUILDING SIZE � � SQ FOOTAGE �� HEIGHT
QBUILDING $/ J�L1 �J v iJ VALUATION OF TOTAL CONSTRUCTION
G%
QELECTRICAL $ AMP SERVICE Q PROGRESS ENERGY Q W.R.E.C.
QPLUMBING $
QMECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
QGAS � ROOFING Q SPECIALTY � OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA QYES NO
BUILDER COMPANY
SIGNATURE REGISTEREO Y/ N FEE CURRE� Y/ N
Address ' License #
ELECTRICIAN COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/ N
Address License # � —�
PLUMBER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/ N �
Address Llcense # �— �
MECHANICAL COMPANY
SIGNATURE _ REGISTERED Y/ N FEE CURRE� Y/ N
Address Ucense #
SIGNATURE �/ I�ly .. � COMPANY t � ' f'!C. � �z j ` � '` "
REGISTERED Y/ N FEE CURRE� Y/ N
Address �L� �� ^X ��� S� ``� i� I� e l.tcense #�� � V S 7%,s �
RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy Forms; R-O-W Permit for new construction,
Minimum ten (10) working days after submittal date. Required onsite, Constructlon Plans, Stormwater Plans w/ Silt Fence installed,
SaNtarv Facilities 8 1 dumnstpr• ctto w�.� ao�.,,�t s,,. �,��„a:.,���,,..��.._,.,. .._.�,.,,...
�`����� �
, �� �
<r 3�' ,� ri c i Rl
�
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
,
� .
� �ontr_act�-Iomeowner:
__ - —(i?I
Date Received: � � /���
)
Site: / � L L � .
' �I�C
Permit Type: � L� �
./�,/��% �",' ��E- �y.,S�� •
Approved w/no comments: Approved w/the below comments: ❑ Demed w the below comments: ❑
This comment sheet shall be kept with the peimit and/or plans.
� � / �1
Kalvin itz — Examiner Date Contractor and/or Homeowner
(Required when comments are present)
Florida Building Code Online Page 1 of 3
=F - .
� �a
_
�'
BCIS Home Log In User Registration Hot Topics ' Submit Surcharge � Stats & Facts � Publicati�
� Product Approval
� ��� USER: Public User
•
` Product Ap�roval Menu > Product or Appllcation Search > A�_p_l�cation_Ust > Ap lication Detail
����� t FL # FL1601-R5
Application Type Affirmation
, R , . � � ° Code Version 2007
��W��� APPlication Status APProved
Comments REVIEW DATE ����- l�
� �► Archived CITY OF ZEPHYRHlLI_S
_,
PLANS EXAMINER�__�
Product Manufacturer Carlisle SynTec
Address/Phone/Email 1285 Ritner Hi�
P.O. Box 7000
Carlisle, PA 17i
(717)245-700
ALLWORKSHALLC4MPLYWITHALI. malpezzi@synt
PREVAILING CODES, FLORIDABUII.DING
Authorized Signature CODE,NATIONALELECTRICCODEAND �oe Mal ez
CITY OF ZEPHYRHILLS ORDINANCES P z�
malpezzi@synt
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Single Ply Roof
Compliance Method Certification M�
Certification Agency FM Approvals -
Validated By
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqtFPmdYiNDWr... 2/17/2011
Flarida Building Code Online Page 2 of 3
Referenced Standard and Year (of Standard) Standard
FM 4470
Equivalence of Product Standards
Certified By
� �=i��rr� ;t1�E
c�--,-:,a , R
Vi!y U(UtIU�.i� ,�
�i�lir7�nia C��dr.
Documentation from approved Evaluation or Validation Entity .,,�,,, ,�;,�
Product Approval Method Method 1 Optic
Date Submitted 02/14/2008
Date Validated 02/14/2008
Date Pending FBC Approval
Date Approved 03/20/2008
Summary of Products
FL # Model, Number or Name Description
1601.1 Sure-Seal, Sure-Weld, Sure- EPDM, TPO and P\
White and Sure-Flex
Limits of Use Certification AgE
Approved for use in HVHZ: Yes FL1601 R5 C C�
Approved for use outside HVHZ: Yes Quality Assuran�
Impact Resistant: Yes
Design Pressure: +495/-495 Installation Inst
Other: Maximum uplift pressure of 495 psf for Sure- FL1601 R5 II 2(
Seal, Sure-Weld and Sure-White. Maximum uplift FL1��1 R5 ii 2(
pressure of 330 psf for Sure-Flex. Safety Factor of 2 FL1601 R5 II At
used to calculate uplift pressures. FL1601_R5_II _At
FL1601 R5 II Cc
FL1601 R5 II FE
FL1601 R5 II FE
FL1601 R5 II Hc
FL1601 R5 II MI
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param�vGEVXQwtDqtFPmdYiND Wr... 2/ 17/2011
Flc�rida Building Code Online Page 3 of 3
� FL1601 R5 II S1
FL1601 RS II S1
FL1b01 R5 II SI
� FL1601_R5_II_S1
� Verified By: FM A
Created by Indep
Evaluation Repo
Created by Indep
Back Next �
Department of Community Affairs
F/orida 8ul/dinp Code Online
Codes and Standa�ds
2555 Shumard Oak Boulevard
Tallahassee, Florida 32399-2100
(850) 487-1824, Fax (850) 414-8436
OO 2000-2010 The State of Florida. All rights reserv�
Privacv Statement � Copvright Statement � Accessibility Statement � Plug-in Software �
Product Approval Accepts:
� � � �
Sf�L.'U17LVM kTNiCS'
v.r�s�oe � - . i
Tr�st�d
�
vER��r �
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param�vGEVXQwtDqtFPmdYiNDWr... 2/17/2011
CARLISLE'S
V���
L .�
GUIDE-SPEC
MECHANICALLY-FASTENED ROOFING SYSTEM
December, 2004
This GUIDE-SPEC is a brief outline of Carlisle's Sure-
F1exT"' Mechanically-Fastened Roofing System requirements and A. To ensure compliance with Carlisle's warranty requirements,
is intended for use as a submittal with a bid package. Specifiers the following projects should be forwarded to Carlisle for
and the Carlisle Authorized Roofing Applicator must comply with review prior to installation, preferably prior to bid.
our Sure-Flex Specification prior to design or bid.
1. Projects with fasteners specified to exceed 12".
PART1 GENERAL
2. Air pressurized buildings, canopies and buildings with
1.01 DESCRIPTION lazge openings where the total wall opening exceeds
10% of the total wall area where openings aze located.
The Sure-FIexTM Mechanically-Fastened Roofing System
incorporates Sure-Flex Polyvinyl Chloride (PVC) membrane, 3 Cold storage buildings and freezer facilities.
available in 81" wide field sheets and 40.5" perimeter sheets. All
sheets are mechanically fastened over an approved 4. Projects where the membrane is expected to come in
insulation/underlayment to an acceptable roof deck with the direct contact with petroleum-based products or other
appropriate Carlisle Fasteners and Fastening Plates. The chemicals.
membrane is available in white, tan or gray and in thicknesses of
50-mil (100' long), 60-mil (80' long) or 80-mil (65' long). B. Along with the project submittals (shop drawings and
Adjoining sheets of Sure-Flex membrane are overlapped and Request for Warranty), the roofing contractor must include
joined together with a minimum 1-1/2 inch wide heat weld. pullout tests when the pullout values are less than the Sure-
Membrane fastening requirements aze outlined in "Attachment II" Flex Specification requirements.
in Carlisle's Sure-Flex Specification.
C. For all projects (prior to proj ect inspection by Carlisle) a final
Notes: Projects utilizing 50- or 60-mil membrane are eligible shop drawing must be approved by Cazlisle.
for a ma�cimum 10-year System Warranty or 15-year
Total System Warranty When a 20-year Total System 1.04 PRODUCT DELIVERY, STORAGE AND NANDLING
Warranty is required, 80-mil membrane must be used.
A. Deliver materials to the job site in the original, unopened
1.02 QUALITY ASSURANCE containers labeled with the manufacturer's name, brand name
and installation instructions.
A. This roofing system must be installed by a Carlisle
Authorized Roofing Applicator in compliance with shop B Store Sure-Flex membrane on provided pallets in the original
drawings as approved by Carlisle. There must be no undisturbed plastic wrap.
deviations made without the PRIOR WRITTEN
APPROVAL of Carlisle. C. Job site storage temperatures in excess of 90°F inay affect
shelf life of curable materials (i.e., adhesives and sealants).
B. Upon completion of the installation, an inspection will be
conducted by a Field Service Representative of Carlisle to D When liquid adhesives and sealants are exposed to lower
ascertain that the membrane roofing system has been installed temperatures, restore to a minimum of 60°F before use.
according to Carlisle's published specifications and details
applicable at the time of bid. E. Do not store adhesive containers with opened lids due to the
loss of solvent which will occur from flash off.
C. This roofing system meets Underwriters Laboratories (ITL)
and Factory Mutual (FM) requirements. For specific code F. Insulation and underlayment must be stored so it is kept dry
approvals achieved with this roofing system, refer to the and is protected from the elements. Store insulation on a skid
Sure-Flex Code Approval Guide, Factory Mutual Approval and completely cover with a breathable material such as tarp
Guide or Underwriters Fire Resistance and Roofing Materials or canvas. If insulation is lightweight, it should be weighted
and Systems Directories. to prevent possible wind
damage
� • �
1.05 JOB CONDITIONS �
1.03 SUBMITTALS A. This system must not be �M� �Tec Incorpora�d
602125 1 Sure-Flex "MF" Guide - 12/2004
applied on projects where the slope exceeds 18" in one the specifier and accepted by Carlisle, is not the responsibility of
horizontal foot. When the roof slope exceeds 5" per Carlisle and is expressly disclaimed by the Carlisle Warranty.
horizontal foot, use of an automatic welding machine may be
more difficult. A hand held welder should be specified. 2.02 MEMBRANE
B Existing roofing material must be investigated by the Sure-Flex white, gray or tan 50-mil (100' long), 60-mil (80' long)
specifier and all wet material must be removed. or 80-mil (65' long) reinforced Polyvinyl Chloride (PVC)
membrane is used for this system. Field membrane sheets are 81"
C. Existing phenolic insulation and sprayed-in-place urethane wide. Perimeter sheets are 40.5" wide. For physical properties of
roofs must be removed prior to installation of this system. the membrane, refer to page 4(Gray and tan colored membrane
aze not standard stocking items and require a lead time).
D. The use of a vapor retarder to protect insulation and reduce
moisture accumulation within an insulated assembly should 2.03 RELATED MATERIALS
be investigated by the specifier. Consult the publications by
ASHRAE (American Society of Heating, Refrigerating and Sure-Flex Non-Reinforced or Reinforced Flashing, Bonding
Air-Conditioning Engineers, Inc.) and NRCA (National Adhesive, Cut Edge Sealant, Water Cut-Off Mastic, PT-304
Roofing Contractors Association) for specific information. Sealant, PVC Membrane Cleaner, One-Part Pourable Sealer, Heat
Weldable Walkway Pads, Pre-Molded Inside and Outside Corners,
E. Coordination between trades is essential to avoid unnecessary Pipe Flashings and Sealant Pockets.
traffic over sections of the roof and to prevent damage to the
membrane roofing system. PART III EXECUTION
1.06 WARRANTY 3.01 GENERAL
All warranties are available for commercial projects only A. When feasible, begin the application at the highest point of
the highest roof level and work to the lowest point to prevent
A. 10-year Membrane System or Total System Warranty is moisture infiltration and to minimize construction tr�c on
available for a charge for projects that use 50-mil, 60-mil or completed sections. This will include completion of all
80-mil membrane. flashings, terminatioas and daily seals.
B. A 15-year Total Roofing System Warranty is available for a B. Follow criteria outlined in the Sure-Flex Specification to
charge for projects that use 50-mil, 60-mil or 80-mil prepare the roof deck or the existing substrate prior to the
membrane. application of the new roofing system.
Mechanically-Fastened Roofing Systems over cementitious 3.02 ROOF DECK CRITERIA
wood fiber or gypsum decks, upon review, may receive a
maacimum 15-year Total System Warranty when building A. Proper substrate shall be provided by the building owner
height is not greater than 40' and a minimum of 3 perimeter The structure shall be sufficient to withstand normal
sheets are utilized. construction loads and live loads.
C. A 20-year Total System Warranty is available for a charge for B• Defects in the roof deck must be reported and documented to
projects utilizing 80-mil thick Sure-Flex membrane and the specifier, general contractor and building owner for
incorporaxing additional design enhancements as outlined in assessment. The Cazlisle Authorized Applicator shall not
this specification. proceed with installation unless defects are corrected.
Note• Total System Warranty projects require that only C. Acceptable decks and the applicable Carlisle Fasteners:
materials from among those manufactured or marketed
by Carlisle be specified and used to complete the 1 • Steel, 22 gauge or heavier - Carlisle HP-X
roofing system. Some of the materials included are: Fasteners/Piranha Plates or HP-Xtra Fasteners/Piranha
insulation, membrane, flashing, adhesives, sealants, Xtra Plates are required with a minimum pullout of 500
fasteners and plates and termination bars. Carlisle pounds per fastener.
Edgings and Copings must also be specified when metal
fascia systems are to be covered by the Carlisle 2• Lig6tweight Insulating Concrete over steel - Cazlisle
W�ty HP-X Fasteners/Piranha Plates or HP-Xtra
Fasteners/Piranha Xtra Plates are required with a
D. Standard peak gust wind speed coverage is 55 mph (measured minimum pullout of 360 pounds per fastener (into steel
10 meters above ground). Greater wind speed coverage, up deck below the lightweight concrete).
to 72 mph peak gusts, is available upon request.
PART II PRODUCTS
3. Structural Concrete, rated 3,000 psi or greater —
2.01 GENERAL Carlisle CD-10 or HD 14-10 Fasteners (with Piranha
Plates) aze required with a minimum pullout of 800
The components of this roofing system are to be products of pounds per fastener
Cazlisle or accepted by Cazlisle as compatible. The installation,
performance or integrity of products by others, when selected by 4 Wood Plank or minimum 15/32 thick Plywood -
Carlisle HP-X Fasteners/Piranha Plates or HP-Xtra
602125 2 Sure-Flex "MF" Guide - 12/2004
Fasteners/Piranha Xtra Plates are required with a
minimum pullout of 360 pounds. 2. Membrane sheets shall be mechanically fastened with
, � the appropriate Carlisle Fastener/Fastening Plate spaced
5. Oriented Strand Board (OSB), minimum 7/16"thick; 6", 12" or 18" on center, depending on project criteria,
The Carlisle HP-X Fasteners/Piranha Plates or HP-Xtra within the membrane splice. Refer to the Sure-Flex
Fasteners/Piranha Xtra Plates aze required with a Specification for required number of perimeter
minimum pullout of 300 pounds per fastener. membrane sheets and fastener spacing.
6. Cementitious Wood Fiber and Gypsum - The Carlis(e 3 Overlap adjacent membrane sheets approximately 5-1/2"
HP-NTB Fastener is required with a minimum pullout of at those locations where Fastening Plates are located
300 pounds. (along length of the membrane) and a minimum of 2" at
end roll sections (width of the membrane).
3.03 SUBSTRATE PREPARATION
4. Heat weld the membrane sheets a minimum of 1-1/2"
A. On retrofit-recover projects, cut and remove wet insulation, with an Automatic Heat Welding Machine.
as identified by specifier, and fill all voids with new
insulation so it is relatively flush with existing surface. C. Additional Membrane Securement
B. For ail projects, substrate must be even without noticeable The membrane must be secured at the perimeter of each roof
high spots or depressions, and must be free of accumulated level, roof section, expansion joint, curb, skylight, interior
water, ice or snow. wall, penthouse, etc., at any angle change which exceeds 2"
in one horizontal foot and at all other penetrations in
C. Clear the substrate of debris and foreign material. Fresh accordance with Cazlisle's Details published with Carlisle's
bitumen based roof cement must be removed or concealed. Specifications.
3.04 INSTALLATION D Membrane Flashing
Refer to the applicable Material Safety Data Sheets and Technical Flash all walls and curbs with Sure-Flex reinforced
Data Bulletins for applicable cautions and wamings. membrane. Non-Reinforced membrane shall be limited to
inside and outside comers, field fabricated pipe seals,
A. Insulation Attachment scuppers and Sealant Pockets where the use of pre-molded
accessories are not practical. Terminate the flashing in
1 Carlisle Insulation shall be mechanically fastened to the accordance with an appropriate Carlisie Tertnination Detail.
roof deck as follows:
E. Other Related Work
a. For HP Recovery Board, Dens-Deck or minimum
1-1/2" thick Polyisocyanurate, a minimum of 5 1. Walkways are required for all traffic concentration
fasteners and plates per 4' x 8' boazd aze required. points (i.e., roof hatches, access doors, rooftop ladders,
etc.), regazdless of traffic frequency. Walkways are also
b For Polyisocyanurate less than 1-1/2" thick or required if regular maintenance (once a month or more)
Foamular or DOW Extruded Polystyrene, any is necessary to service roo8op equipment. Walkways
thickness, a minimum of 6 fasteners and plates per are considered a maintenance item and are excluded
4' x 8' boazd aze required. from the Carlisle Warranty,
Note: Sure-Flex PVC membrane cannot be a. Sure-Flex Heat Weldable Walkway Rolls are
installed directly over extruded required when walkway pads are specified and aze
polystyrene insulation. A layer of HP heat welded to the Sure-Flex Membrane.
Protective Mat must be installed over the
insulation prior to installing membrane b. When concrete pavers are used, they shall be loose
(approved with white Sure-Flex laid and installed in conjunction with a slip sheet of
membrane only). reinfocced membrane. Concrete pavers are not
recommended when the roof slope is greater than
c. Insulation boards 4' x 4', regardless of thickness, 2" per 1 horizontal foot.
must be fastened at the minimum rate of 1 fastener
and plate every 4 square feet. c. Carlisle InterlockingTM Rubber Pavers, 24" X 24"
X 2", weighing approximately 6 pounds per square
2. Cazlisle Piranha Plates, Seam Fastening Plates (2" foot may be loose laid directly over the membrane.
diameter) or Insulation Fastening Plates (3" diameter) Installation instruction sheets are available from
may be used with appropriate Carlisle Fastener for Carlisle.
insulation attachment. 2. Copings, counterflashing and ot6er metal work, not
supplied by Carlisle, shall be fastened to prevent metal
B Membrane Placement, Attachment and Heat Welding from pulling free or buckling and sealed to prevent
moisture from entering the roofing system or building.
1. A minimum of two perimeter sheet shall be installed at
edges of each roof level and 81" wide membrane shall Attach copies of the applicable Carlisle Details t6at pertain to
be installed in the field of the roof. the ind'mdual project to complete a bid package submittal.
602125 3 Sure-Flex "MF" Guide - 12/2004
Membrane Ph sical Pro erties
Property of Unaged Property After ASTM
Physical Property Test Method Sh � D3045 aging 56 days
176° F
Tolerance on Nominal Thickness, % ASTM D 751 t 10
Thickness over scrim, in. (mm) ASTM D 4434
50-mil & 60-mil Optical Method 0.016 (0.406) min.
80-mil av . of 3 areas 0.025 0.635 min.
ASTM D 751 200 (35j min. 90% min. retention of
Breaking Strength, Ibffin. (kN/m) (Grab Method) 300 (53) typical original breaking strength
Elongation at Break of fabric, % D 751 15 min. 90% min. retention of
25 ical ori inal elon ation
Tearing Strength, Ibf (N) 8 x 8 in. specimen ASTM D 751 45 (200) min.
B-Ton ue Tear 100 445 t ical
Low Temperature Bend, ASTM D 2136 -40 (-40) max.
-50 -46 t ical
Linear Dimensional Change (shrinkage), ASTM D 1204 +/- 0.5 max.
After 6 hours at 176° F 80° C -0.3 ical
Ozone resistance,100 hm, 168 hours ASTM D1149 No cracks
Resistance to water absorption
After 7 days immersion 158° F(70° C) ASTM D 570 3,0 max.
Chan e in mass, % 2.0 typical
Field seam strength Ibffin. (kN/m) ASTM D1876 z5 (4.4) min.
Seam tested in eel after weldin 60 10.5 t ical
Water vapor permeance, Perms ASTM E 96 0.10 max.
0.05 t 'cal
Puncture resistance, Ibf (N) 250 (1110) min.
(see supplemental section for additional puncture data FTM 101C 280 (1245) typical 50-mil
Method 2031 320 (1423) typical 60-mil
3801690 ica180-mil
Resistance to xenon-arc weathering ASTM G155
Xenon-Arc, 6300 kJ/m= total radiant exposure, visual condition 0.35 W/m' No aacks
at 10X (ASTM D 4434 light & spray cycle) 63 ° C No crazing
5000 hours
B.P.T, is black anel tem rature
Copyright 2004 Carlisle SynTec Incorporated
Carlisle, Sure-Flex, Interlocking are Trademarks of Carlisle SynTec Incorporated.
Foamular is a Trademark of UC Industries, Inc.
Cazlisle SynTec Incorporated, P O Box 7000, Carlisle, PA 17013-0295
Phone:800-479-6832 http://www.carlisle-syntec.com
602125 4 Sure-Flex "MF" Guide - 12/2004
� S�e� Proposal/Contract
. sc�ztt z� �' • , ��c.
� P.O. Box 1188 • 33010��
San Antonio, FL 33576 �ra��wee�l,
�, (352) 588-R04F (76�3) • (813) 782-1330 �'s���G &
Fax (352) 588-9763 ?,�
www.scottblackmanroofing.com
�°°�"'�� email: blackmanroofingC�aol.com Date �� � v
G(��G 457957
_ PRO POSAL SUBM(TfED TO WORKED TO BE PERFORMED AT �
Name _�/r� ___�� � r Street
Street � C�� c 4 !�i f 5" /P✓d� C"tty — -- -- __
City _� ��l—G� Li� �� _ --
State _ Z�p
State _� � _ _ Zip Owner of Property
Phone Number _ _ Fax Phone Number__ _ F�
We hereby propose to furnish ali the materials and perform all the iabor necessary for the compietion of:
U Remove existing shingle roof Cl Replace bad fascia boards at $_ per foot
J Remove existing buiit-up roof ❑ Replace t x decking at $ per foot
U Dry-in with U i 5 ib. U 30 Ib. CJ Install feet of ridge vents
J Dry-in with a fully adhered underlayment $ 0 Install modified bitimen (granulated) torch down roafing
U Install new galvanized valley metal additional
black, white or other color
U Install new lead boots 0 fnstall 25 yr. fungus resistant 3-tab shingles
t_l Install new exhaust vents ❑ Install 30 yr. fungus resistant dimensional shingles
J Install new drip edge, _____ color
color
U Install new flashing as needed nstall TPO, white rubberized roofing membrane
U Replace plywood at $ _ per sheet ❑ ther:
�l Repair ratten trusses at $_ __ per foot ' �
*Woodwork is an additional charge, see pricing above —
All material is guarantsed to be as specified, and the above work is to be performed is accordance with the drawings and specifi-
cations submitted for above work and completed in a substantial workmanlike manner for the sum of $_ y�j)�,7d �L�
with payments to be made as follows: Pavment due in full on completion, un less otherwise noted. Thank You
— -- ^._ Credit cards accepted, additional 2.8% charge.
"Not responsible for satelite signal when sateiite is rei�stalled 'Not responsible for A/ & electrical lines too close to roof decking
Any alteration or deviation from abov� specifications involving extra costs will
be executed only upon written orders, and will become an extra charge over and
above the estimate. Alt agreements contingent upon strikes, accidents or delays —
beyond our control. Owner to carry fire, tornado and other necessary insurance Officer/Agent Scott Blackman Roofing
upo� above work. Workers' Compensation and Public Liability insurance an above Note: This pr osal may be withdrawn by us if not acceptec
work to be taken out by Roofing Contractor Extreme caution should be
used during and after constructfon for debNs and nails missed duNng Wtthlfl days.
cleanu
ACCEPTANCE OF PROPOSAL
The above prices, specifications and conditions are satisfactory and are hereby accepted. You are authorized to do the work as
specified. I have read the back of this Proposal/Contract, which contains Florida Statues 713.Od1-713.37. Payment will be made as
outlined above. Cl�nt gives permission to drive on driveway to deliver materials
Accepted ` � nature �
n.,r,.
n ___.. .._
i iiiiii iiiii ii�ii iiiii iiiii iiiii iiiii iiiii iiiii iioi iiii iiii
2011024588
Rept:1351301 Rec: 10.00
D5: 0.00 IT: 0.00
02/16/11 K. Garcia, Dpty Clerk
PRULA S 0'NEIL Ph D PRSCO CLERK & COMPTROLLER
02/16/11 01:17 m 1 of 1
OR BK 85 �4 PG 3��7
NOTICE OF CONIMENCEI�IENT
Permit No
Property Identification No 3s —�-- Z �-0 V O c,aov� - aaS'3
THE iTNllERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Section
713 13 of the Florida Statutes, the following information is provided in thisN OTICE OF COMN�E�10E ENT.
Pa s� � �CGII c c. q l►�'r Pc,n f v P TS � P t� Z N a�F z 7��
1 Description of property (legal description :) p .� pv'N„ 3,S' 1 o'� �..p�` ,s t�2 S'�- f`�'� f J� � S� a
a) Street Address. � 9�- M 't �. t.r�• F '{ p
2 General descnption of improvements v�v v� !/� O ,,, �..�
3 Owner Information . /� ��- ,s � �
a) Name and address. � YI IS �„ Mo�we �a V s� �� 3�C IrN ���'1'f" /T�/C ��►'�'f/� ��CVl��ce�
b) Name and address of fee simple titleholder (if other than owner) ,� lo j,
c) Interest in property
4 Contractor I�formation
a) Name and address tv�qc k�'''��►rt/la�n�s - j - �� 33�r �S�S� P� R�;clld'k n�,�h�� f�.3 �
b)TelephoneNo 352-fS�-7(o(v?j FaxNo (Opt.) 35Z-S���b 3
Surety Information
a) Name and address•
b) Amount of Bond.
c) Telephone No • Fax No. (Opt.)
6 Lender
a) Name and address
Phone No
7 Idenhty of person within the State of Florida designated by owner upon whom notices or other documents may be served
a) Name and address:
b) Tele}lhone No Fax No (Opt.)
8 In addition to himself, owner des:gnatcs the f�llc�.vir.g pNrson to receive :i copy of the Lienor's Notice as provided in Section
713 13(1) (b), Florida Statutes
a) Name and address
b) Telephone No.: Fax No (Opt.)
9 Expiration date of Notice of Commencement (the expiration date is one year from the date of recording unless a different date is
Specified):
WARNING TO OWNER: �NY PAYMENTS MADE BY THE OWNER AFTER TAE EXPIRATION OF THE NOTICE OF
COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13,
FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.
A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED fJN THE JOB 5ITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR AN ATTORNEY BEFORE
COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCE ENT.
STATE OF FLORIDA /� �, � /Z �
COUNTY OF PASCO ��� �/
Signa re o wner or Owner's Authorized Officer/Director/PartnedManager
�iJ�, /�'lichc�t��
Print Narhd -
The foregoing instrument was acknowledged before me this ���day of C" � , 20�, by h I S�_
lM �1 h �` �'ik �� as D i.J "� t v (type of authorrty, e g. offic r, trustee, attorney
in fact) for (name of party on behalf of whom instrument was executed).
Personally Known �. OR Produced Identificat�on Notary Signature ���¢�--