Loading...
HomeMy WebLinkAbout11-11475 CITY OF ZEPHYRHILLS � . 5335-8th Street (ai3)�ao-ooao 11475 ELECTRICAL PERMIT Permit Number: 11475 Address: 7320 GALL BLVD Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: ELECTRICAL MISC Township: Range: Proposed Use: COMMERCIAL Lot(s): Block: Section: Contractor: MGQ & ASSOCIATES INC Book: Page: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 35-25-21-0010-08800-0000 Improv. Cost: 1,870.00 Date Issued: 2/02/2011 Name: TOWNVIEW RETAIL LLC Total Fees: 67.50 Address: 725 CONSHOHOCKEN STATE RD Amount Paid: 67.50 BALA CYNWYD PA 190042102 Date Paid: 2/02/2011 Phone: (610)667-5800 Work Desc: LOW VOLTAGE CABLE - SAVE O LOT ELECTRICAL FEE 67.50 i 'n �� F ROUGH ELECTRIC CONSTRUCTION POLE PRE-METER FINAL — — REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to any one of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspection called d) work not ready for inspection when called e) permit not posted on job site fl plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. The payment of inspection fees shall be made before any further permits will be issued to the person owning same. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordi CO CTOR PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER . sis-�ao-oozo City of Zephyrhills Permit Application Fax-813-780.0021 � . Building Department Date Rer.eived � — � / � s -- ��j � � �// r' � Y "` �J Phone Contact for Permittin r T - n r Owner's Name Owner Phone Number Owner's Address Owner Phone Number �� /y ,! 1! ✓� Fee Simple TiUeholtlerName Owner Phone Number Fee Simple Tltleho�der Address JOB ADDRESS � O L �� I 4� . G �� /' LVT # � SUBDtVIS10N PARCEL IDq (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT Q SIGN Q Q DEMOLISH � INSTALL e REPAIR PROPOSED USE Q SFR � COMM Q OTHER TYPE OFCONSTRUCTION Q BLOCK FRAME 0 STEEL Q DESCRIPTION OF WORK � Y (/�^��— �� �-Q- UC.. / �LC '! � � �} 'e (,� �/ � BUILDING SIZE SQ FOOTAGE � HEIGHT T �BiJiLDING $ VALUATION OF TOTAL CONSTRUCTION l T Q (� e �EI.ECTRlCAL $/�/ �, AMP SERVICE Q PROGRESS ENERGY Q W.R.E. ., Lvw Y'r71. �- �c C� .yL l�c.Ct �' ✓ d � (JD� �i PLUM8ING $ C� �PAECHANICAL $ VALUATION OF MECHANICAL INSTALLATIO� C1GAS Q ROOFWG Q SPECIALTY Q OTHER FiNISHE D FLOOR ELEVATIONS FLOOD ZONE AREA QYES NO^ � `� � j// O� , /`.:,�ST.?/� . � 1� . , BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CURRE� Y J N Address License # �� ELECTRIGAN COMPANY � SIGNATUR£ � REGISTERED Y/ N FEE CURRE� Y/ N Address License# �� PLUMBER COMPANY � SIGNATURE REGISTERED Y/ N FEE CURRE� Y/ N Address License # MECHANICAL COMPANY � SIGNATURE � q� REO Y/ N FEE CURRE� Y! N Adtlress . License # �—� OTHER COMPANY /�I � lJ� � Z7OC / Q��PS SiGMATURE �^�� REGISTERED N FEE CURRE� N Address � / � � f!/ ,$ � . T /z' L ,�j ��00� license # G�� � 0�� S� � IIlIIIIII1111111111111111111111111111111111111111111111111111111111 RESIDENTiA� Attach (2) Plot Plans; (2) sets of Bwlding Plans; (1) set of Energy Fortns; R-O-W Pertnit for new construction, Minimum ten (10) working days afler submittal date. Required onsite, ConsVuction Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities & 1 dumpster; Site Wark Pertnit for subdivisions/large projects COMMERCIAL Attach (3) complete sets of Building Plans plus a Lrfe Safety Page; (1) set of Energy Fortns. R-O-W Pertnit for new construaion. Minimum ten (10) working days afler submittal date. Required onsite, Construction Plans, Stormwater Plans w/ Silt Fence installed, Sa�ita'ry facilities & 1 dumpster Site Work Pertnit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engmeered Plans. ""'PROPERTY SURVEY required for all NEW construction Direcuons • Ftl! out application completely c�wner � Contractor sign back of application, notarized If over $2bOb, a Notice of Commencement is required. (AIC upgrades over 57500) " Agent (for the contractor) or Power of Attomey (for the owner) would be someone with notanzed letter from owner authonnng same OVER THE COUNTER PERMITTING (Front of Appiication Only) Reroofs �f shmgles Sewers Service Upgrades A/C Fences (PIoUSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicabie deed restrictions. UNIiCENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or cor�tractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009 Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of ezisting buildings, as specified in Pasco County Ordinance number 89-07 and 90-o7, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of perm;tting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiwng a"certificate of occupancy" or final power release. If the project dces not involve a certificate of occupancy or finai power refease, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTiON LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I ce::ify ;hat I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other ?han the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to del�ver it to the "owner" prior to commencement. CCNTRACTOft'SlOWNER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work w�ll be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I ceRify that no work or installation has ccmmenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating corstruction, Courrty and City codes, zoning regulations, and land development regulations in the jurisdiction. I also ceaify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to. - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Welis, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. i understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone "V" unless expressly permitted. - if the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - tf fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. if ! am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit p�ior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid un!ess the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building O�cial for a period not to exceed ninety (90) days and will demonstrate jus*.ifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYlNG TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YO R LENDER OR AN ATTORNEY BEFORE RECORDtNG YOUR NOTICE OF COMMENCEM NT. FLORIDA JUR.4T (F S. 117.03) , �� � , OWNER OR AGENT CONTRACTO Subscri4ed and sworn to (or aifirtned) before me this S crib d and swom to�D{ affirmed) before me this bY 4 by ��S c� r,_ n C C' �� f Vdho is�are personally known to me or has/have produced Wh is/are p aily known to me or has/have produced _, as ident�cation. � as identification. / __ Notary Pubiic _Notary Public Ccmm;ssion No. Commission No. ��� L � �J b�� �G � I`��OC �.J Name o` Notary rypetl, printed or stamped Name of Notary typed, p ted or stamped �""°�, ROGER ABREU �/� MY COM�SSION N DD9�SE62 '� EXPIRFS. Dxmiber 10, 2013 �.eoo-uarnrtr Fl. No1+Y DiwaoM MwC. Co. � ' , Pa�e l of 3 . �-( �- g �.��-- l Manny Quevedo r �A,,,,r+�-� �� . � ( From: sharepoint@bailiwick.com Sent: Thursday, December 23, 2010 12:18 PM To: manny@mgqassociates_com Cc: reverroad@bailiwick.00m Subject: Bailiwick Data Systems site scheduled natification for sav site #� 336 BA1L1W1GK This is an automated notification — please do not reply. This email is to confirm MGQ & Associates, Inc. - Corporate has been scheduled to complete a work order for Bailiwick: Bailiwick Client Name: sav Client Site �#: 336 Scheduled Start Date and Time: 2l2/20118:00:00 AM Bailiwzc Purchase Order #:L278�5 �� � O /t�/� . Please ensure that the Technician assigned to the work order has all project documentation needed prior to arrival at the site. Please note that the Bailivrick Project Contact may provide additional information �vhich is not contained in this Work Order Confirmation. . Please ensure a prompt on time arrival. Technician must check in with the Bailiwick Service Desk at 866-777-3227 upon arrival. Contact Information: If you have any questions reg�rding this work order, please contact the Bailiwick Project Contact listed below. The Bailiwick Project Contact will provide you with any further information or do�umentation such as rnanuals or sign off forms necessary to complete the work order. Bailiv►�ick Project Contact: Rich Everroad Contact P4�one: 952-556-3$96 Contact Email: reverrosd�bailiwick.com SiEe Information: Bailiwick Client Name: sav Client Site #: 336 Baili�sick Project Contact:Rich Everrosd �� QQ �E SW�'TL�'� Address 1: 7320 G$ll Blvd. ��'�' N- Address 2: S�ve a Lot 3 �� F�x i z�23 2010 6'd LLL8LL8£68 se;ei�ossy�gb�W egg:06 ll tiZ ��(' � Page '? ot s City: ZephyrhiUs State: FL Zip:33541 Base Budget: 51870 Bailiwick Purchase Urder #: L27855 Please note that all of the Site Information listed above must be included on your invoice to Ba'rinvick. Invoieing Inforrnation: All information listed in the Site Information section of this work order must be included on your invoice to Bailiwick. Remit all invoices directly to Bailiwick, ATTN: Aecounts Payable, 4260 Norex Drive, Chaska, NiN 55318 or email to AccountsPavablecu'�,Bailiwick.com. Invoices must be received rvithin (10) business day�s of completion of the work order. Deliverables Information: All work order deli��erables (digital pictures, test results, sign of�forms) must be received by Bailiwick within the time frame specified by the Bailiwielz Project Contact or Baili�vick project documentation. Deliverables must be sabmitted via the Vendor Partner Portal at https:!/uplo�d.bailiwick.com unless specifically iastructed otherwise by the Bailiwick Pro,jeet Cont�c� The Site # and PO # from this work order are required to access the Portal. Deliverables mnst be eomplete and accurate aod are required before the site invoice can be pa'rd. Work �rder Details: The information below provides basic details regarding the work order. rhe Bailiwick Project Contact will provide you with any further information or documentation such as m�nuals or sign off forms necessary to complete the work order. Please ensure that the Teehnician assig�ed to the work order has all project documentation needed prior to arrival at the site. . Teck�nician must check in with the Bailiwick Service Desk at 866-777-3227 upon arrival at the site. Bailiwick Client Site #:336 Scope of Work: Installation of data cabling to the following locations: Frora Office to each of the cash lanes From Office to center of the store for Access Point From Office to break roam for People soft coroputer From office to Safe outside of office From Office to Wall ontside office for Kronos Time clock Run 3 phone lines to office from demark Run phone line for sprinkler pan►ei Run phone Gne for Alarm panel Extend Frame from dernark to of�ice 12/?3i2010 Z'd LLL8LL8£68 se�eioossy��j�w egc,:Ol 66 tiZ ��f ' Paae 3 of 3 Extend DSL from demsrk to office Iostall Router, 2 switcl�es, modem, �nd cabiQet in office Install kronos clock oatside o�ce NOTE: - VP needs to check with loeal mnnicipal for lo�v voltage permit requirements and let BW knovv prior to starting work. Estimated Task Duration: 16 to 32 man hours Special Tools amd Certifications Required: Butt set, punch down, digital camera Vendor Provided Materials Required: Aa eed Budget: S1870 Agreed Budget Notes: - Budget includes labor and travel for cabGng and equipment instaliation. - Permit, if required, is not included in the budget and would be billed as a change order.(Permit must be obtained before install) - Bailiwick is to provide all materials for the site installation - Out of scope, additional labor hours, and/or change order work must be escalated to the Bailiwick PM for authorization prior to imp[ementation. - Thank you! . Technician must check out with the Bailnvick Service Desk at 866-777-3227 before departure frora the site. Thank yo�! 12/23; 2010 £'d LLL8LL8E68 se}ei�ossy�g�j�W eg,:p� �� �Z ue� �c�.,�� of W'ork: Installation of data cabling to the following locations: Fr�.�n Off�ce to each of the cash lanes 1Fr+ ,rrs �ftice to center of the store for Access Point �ra: rz Offece ta break room for People soft computer F'r� r c�ftice to Shfe outside of office �r�=�ip �)ff'icc t�� �all outsic�e office for Kronos Time clock �t��;� s�hone 1ine� to otfice from demark �u� ;�Itiora� lin� f'�r sprinkler panel �Zu=F ��t�on� �ine for• �larm panel �: e�����" Fa-xr�e f'rc�m demark to office ��i �: :.�fk�� �:�1, fr�m t�em�rk to office °���. .siti ��outcr, 2 switch�s, modem, and cabinet in office s���,�?t �:r€�nd�� clack outside office �f� �� City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: �/ l��� /�t f G� S�j' Date Received: � Z �/ /� Site: 7 3 2 b �14 �� �� �� Permit Type: C. G(� /�D -� ' , 4��e .S'� �� Approved w/no comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet sh 1 be kept with the permit and/or plans. E � -1 Kalvin Swi r P xaminer D te Contractor and/or Homeowner (Required when comments are present) cn a N U 3 0 V v V 0 ¢ u3 d 0 r+ 0 N mm E2 AUK I CR -27 CR - 6'4" AFF, FOR MUSIC �_7 21 AND INTERCOM. L- ' CR -11 L-19 L-25 Lam L-23 S ¢ IG 8' -0" AFF FOR CCTV CR- CR -13 L-Z4 L 26 Ir32 3 CR-31 L-20 Ir22 "'*� CR -24 2 (E) 18 IG 0 00 CR -15 (�)= PROVIDE (2) 3/4" EMPTY CONDUITS L-38 FOR SECURITY WIRE AT SAFE FROM 3 #10 /30A 6" A.F.F. TO ABOVE CEILING. CR- 11,CR -12 IG CR- 9,CR -10 IG- CR -25 6 CR -18 CR- 7,CR -8 IG P WP GFI CR- 5,CR -6 IG WP (p CR -24 ' LEA , in RTU-1 EE DUCT DETECTOR NOTE, CR -3,CR4 IG �(Typ) THIS SHEET. (TYPICAL) CR -26 1 ( 60" — H -1 K- 33,35 V r GFI 11 K- 37,39,41 H-5 -J , #1 30A � —DUCT DETECTOR 14 •-' J REMOTE TEST 1 H -12 SWITCH TO ROUGH -IN, +60" LY CR 24 13�K -13 GF1 WP AMP PANEL a; (FURNISHED /DISCONNECT ' K -27;2 WITH COIIi 12 RACK)) 0� , (�) s P O ;.' H-3 --�2 - H - I `I1' K-38 _K H -7 CR- 28iK -9 3 #�0 /30A G31 MSB-1 113 p reL _K -7 � COIL &10 L-11 L-9 L-15 L-17 # 16 H -1 -� PROVIDE N3R/ 30/ 2/ NF/ 240V IC.18,20, fig #6 DISCONNECT (NP. AT EACH EVAP.) 1. �H- 16,18,20 G10 L -12 L-14 COMPRESSOR RACK TO GFI ... H4 (TIE) BE LOCATED LV THE FIELD. WP U2 VERIFY LOCATION PRIOR z 3 #10 /30A MAIN DISTRIBUTION 17 PANEL'MS$' ' EXISTING UTILITY ' E PAD MO O MOUNTED ;� _ i G>r Y H - ;. EE 'BC' H-8 H -10 K-42 3 #10/30A 22 tAB' 4 .I 3 #10 /30A 1 CD p GF)E r 17 7 TRANSFORMER + K -36 15 K' J CR- 1,CR -2 IG� S r, D 0 K -21 K-23 FIOUJER PLAN r. 1 CR -20 g CR -22 I ( } 1/6" = 1' -m" DUCT DETECTOR NOTE 120 VOLT DUCT DETECTOR WITH REMOTE TEST SWITCH. DUCT MOUNTED SN10KE DETECTORS ARE FURNISHED, INSTALLED, AND LOW VOLTAGE WIRED BY MECHANICAL CONTRACTOR. 120 VOLT POWER TO THE DETECTOR SHALL BE PROVIDED AND WIRED BY THE ELECTRICAL CONTRACTOR. S = SUPPLY SIDE R = RETURN SIDE HVAC & PLUMBING EQ. WIRING SCHEDULE UNIT NUMBER 15. NEW SERVICE DISCONNECTS AND METERS FOR SERVICE; DISTRIBUTION. SEE POWER RISER DIAGRAM, SHEET E301, FOR ADDITIONAL POWER NOTES O FUSES INFORMATION. 1. PROVIDE (1) CAT 5 CABLE TO OFFICE COMPUTER AND (2) CAT 3 CABLES TO TELEPHONE BOARD. TERMINATIONS AT EACH END BY SAL 16. PROVIDE 60A /3P NEMA 1, NON -FUSED DISCONNECT ANND CONNECTION TO OWNER FURNISHED BALER. VERIFY REQUIREMENTS AND 45 VENDOR. VERIFY ROUTING AND REQUIRED LENGTHS PRIOR TO ROUGH -IN. 3 #6 &1 #10 E.G. REQUIRED TERMINVATIONS AND PROVIDE ACCORDINGLY. 2. 2- COMPARTMENT POWER POLE FOR POWER AND COMMUNICATION CONDUCTORS. VERIFY REQUIRED CAPACITY, STYLE AND LENGTH 17. OUTLET BOX AND CONNECTION TO OWNER FURNISHEID HAND DRYER. VERIFY EXACT LOCATION PRIOR TO ROUGH -IN. MAKE ALL 2 #8 & 1 #10 EG WITH OWNER AND PROVIDE ACCORDINGLY. REQUIRED TERMINATIONS. 3. PROVIDE (2) 1" CONDUITS WITH PULL STRING FOR CCTV. EACH CONDUIT SHALL TERMINATE IN A FLUSH :MOUNTED OUTLET BOX IN AN ACCESSIBLE LOCATION. VERIFY OUTLET' BOX LOCATIONS PRIOR TO ROUGH -IN. 18. EXISTING ROOFTOP UNIT TO REMAIN AS-IS. FIELD VERIFY TO MAINTAIN ALL EXISTING ELECTRICAL CONNECIIONS. U C9 WALL AND ABOVE CEILING IN 19. � CTION TO OWNER FURNISHED UNI -LIFT. VERIFY ACTUAL PROVIDE 60A / 3P NEMA 3R, NON - FUSED, PULL TYPE DISGCONNECT AND CON NE 4. PROVIDE 4'X8' UL LISTED FIRE RETARDANT PLYWOOD TELEPHONE BACKBOARD WITH TOP AT T AFF. PROVIDE #6 BARE CU GROUND AND TERMINATED TO CU GROUND BAR (ILSCO #D167 -10 OR EQUIVALENT). LOCATE QUAD REQUIREMENTS AND LOCATION. BONDED TO NEAREST BUILDING STEEL RECEPTACLE ON BOTTOM RIGHT CORNER OF BOARD. EXTEND (1) 2 TO MAIN TELEPHONE DEMARK ON EXTERIOR OF BUILDING. 20. MAIN SWITCHBOARD AND BRANCII PAN ELBOARDS, LNJ THIS ROOM, ARE EXISTING "TO REMAIN AND BE REUSED FOR NEW o 6' A.F.F. WITH (1)1" CONDUIT (EMPTY W /PULLWIRE) TO ABOVE CEILING FOR MUSIC AND O RISER DIAGRAM AND PANE'sL SCHEDULES FOR NEW CIRCUITING AND /OR REQUIRED MODIFICATIONS AND 5. PROVIDE FLUSH MOUNTED OUTLET BOX AT -4" TERMINATE IN AN ACCESSIBLE LOCATION WITH INSULATING BUSHING. PROVIDE AC ORDINGR INTERCOM. TO AIR CURTAIN, VERIFY LOCATION AND TERMINATIONS AND PROVIDE ACCORDINGLY. 21. EXISTING EXHAUST FAN TO REMAIN. FIELD VERIFY EXIESTING CIRCUIT AND CONTROL AND MAINTAIN ACCORDINGLY. 6. JUNCTION BOX AND CONNECTION IN CEILING FOR CUSTOMER AWARENESS MONITOR. VERIFY EXACT LOCATION PRIOR TO ROUGH-IN. PROVIDE ALL 22. LR TED IN FRONT MEZZ AN OF ADJACENT SPACE VERIFY ROUTING LENGTH, 'D TERMINATIONS PRIOR TO ROUGH-IN. ARD 7. DUPLEX RECEPTACLE M O NECESSARY SUPPORTS. 8. COIL AND CAP CONDUCTORS IN JUNCTION BOX ABOVE CEILING FOR FUTURE CHECK - STAND. GENERAL NOTES OWNER FURNISHED AUTOMATIC DOOR. VERIFY LOCATION AND TERMINATIONS AND PROVIDE 1 ' ALL LENGTH GREATER THAN 100 FT SHALL BE INCREASED TO #10 AWG AND TO # 8 AWG WHEN GREATER THAN 160 FT. 9. OUTLET BOX AND CONNECTION TO EASE O UI'T FOR ACCORDINGLY. 2. REFER TO HVAC WIRING SCHEDULE FOR CIRCUITING RtEQUIREMENTS OF SAME. 10. RECEPTACLE FOR PALLET JACK BATTERY CHARGER. VERIFY LOCATION WITH OWNER PRIOR TO ROUGH -W. FOR MEAT GRINDER. VERIFY NEMA CONFIGURATION OF ACTUAL EQUIPMENT AND PROVIDE 3. WORKING CLEARANCE SHALL BE AFFORDED TO ALL FILE CTRICAL EQUIPMENT LET ACCORDANCE WITH NEC 110.26. 11. PROVIDE 208V/3P/30A RECEPTACLE CORRESPONDING RECEPTACLE. 4. ALL 15 & 20A, 120V RECEPTACLES WITHIN 6FT OF A SINIK SHALL BE GFCI PROTECTED. 12. PROVIDE WEATHERPROOF RECEPTACLE FOR EVAPORATOR CONDENSATE HEAT TRACE. VERIFY REQUIRED LOCATION. 13, PROVIDE DOORBELL (EDWARDS #340 -4G5), PUSHBUTTON (EDWARDS #1786C -B) AND TRANSFORMER (EDWARDS #592). LOCATE BELL PER OWNER'S DIRECTION. i 14. EXISTING METER AND SECONDARY FEEDER TO BE REMOVED. REFER TO POWER RISER DIAGRAM, SHEET E301, FOR ADDITIONAL INFORMATION. D 0 K -21 K-23 FIOUJER PLAN r. 1 CR -20 g CR -22 I ( } 1/6" = 1' -m" DUCT DETECTOR NOTE 120 VOLT DUCT DETECTOR WITH REMOTE TEST SWITCH. DUCT MOUNTED SN10KE DETECTORS ARE FURNISHED, INSTALLED, AND LOW VOLTAGE WIRED BY MECHANICAL CONTRACTOR. 120 VOLT POWER TO THE DETECTOR SHALL BE PROVIDED AND WIRED BY THE ELECTRICAL CONTRACTOR. S = SUPPLY SIDE R = RETURN SIDE HVAC & PLUMBING EQ. WIRING SCHEDULE UNIT NUMBER DISCONNECT BRANCH CIRCUIT SWITCH FUSES CONDUIT WIRE PANEL RTU-1 N3R/60/3/240V 45 1" 3 #6 &1 #10 E.G. H- 29,31,33 EWH -50 NI/60/2/240V N.F. 3/4" 2 #8 & 1 #10 EG H -21,23 9_1 F. , r d ARTISTIC SOLUTIONS HALO, INC. (CONSULTANTS) ASHLEIGH ADAMOSKY 6822 22ND AVE. N. SUITE 335 ST. PETERSBURG, FL 33710 813- 495 -0917 ASHB076 @HO TMAIL . COM � O o a, t� W o 04 r � �� V U A n w O W 6­4 e o 9 z 1vQa WITH ALL PREVAILING CODES, FLORIDA BUILDING CODE, NATIONAL ELECTRIC CODE AND "'ITY0HEPHYRHILLS ORDINANCES Vi r_ v "v "OAT C) 'ry 1_ UF Z6f'IIy�fIILL �'I -DNS t- }AMlNtif7 MR POWER PLAN ASH PROJECT #: 710 -009 E201 09 -02 -10 w il- z W U C9 o o o IL Y I W �- ww M O O .i..a N W z i MR POWER PLAN ASH PROJECT #: 710 -009 E201 09 -02 -10