Loading...
HomeMy WebLinkAbout11-11739 , , CITY OF ZEPHYRHILLS � 5335 - 8TH STREET (si3)�so-oozo 11739 FIRE SPRINKLER SYSTEM PERMIT Permit Number: 11739 Address: 7952 7954 GALL BLVD Permit Type: FIRE SPRINKLER SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE-SPRINKLER SYS Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: ZEPHYR COMMONS Est. Value: Parcel Number: 35-25-21-0010-00700-0000 Improv. Cost: 2,390.00 Date Issued: 4/12/2011 Name: ZEPHYR COMMONS LLC Total Fees: 260.00 Address: 3629 MADACA LANE Amount Paid: 260.00 TAMPA FL 33618 Date Paid: 4/12/2011 Phone: (813)927-0011 Work Desc: ADD 10 SPRINKLERS RELEASE 20 FOR PROPER COVERAGE- FIVE GUYS 5 . 11 . FIRE PLAN REVIEW FEES 100.00 � � � /� �� � � l / 1 FIRE ACCEPTANCE Final Chapter 633, Florida Statutes, authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees, and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of $100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE REC RDI G YO R NOTICE OF COMMENCEMENT." �.. CO TOR NATURE I IC R ERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT - Fire Marshal Office - 813-780-0041 'J`?AC� Af�'� RETAiN'�IS STATEMEIJT THE ATfAGHED �HECK I`, IN PAYMEM OF ITEM:� CF'�.iBf �� �N �F N"�, i CRRt�=' �.LO..: NOTIFY US GROMGiLY NO RECEIPT DESIRED FRONTLINE FIRE PROTECTION, INC. DATE ACCOUNT DESCRIPTION AMOUNT �. � �-�-�,..� � �Q ��,--� �- y ---. � � �.z- e� 3aso-on,2o City of Zephyrhills Fire Fax-813-780-0021 Permit Application Date Received C( Phone Contact for Permit 8 l 3 �'(8 � ��� Owner's Name ti � � —(, S — � (` ,r�,✓�o pw�ers Phone Number � � � Owner's Address Fee Simple Titieholder Name Titleholder Phone Number �� � Fee Simple Titleholder Address Job Address � �� � � t1�. � l � � � Lot # � Sub Division Paroel # � Bio-Hazard Waste Storage - ANNUAL � Fumigation Tent � Comm Exhaust Kitchen Hood/Duct � Hazardous Material (Tier II or RQ Facility) ANNUAL � Controlled Bum � Hood Installation � Emergency Generator < 30 kw � LP/Natural Gas-Installation � Emergency Generator > 30 kw � LP/Natural Gas-ANNUAL Sale � Fire Protection Maintenance - ANNUAL � Places of Assembly-ANNUAL ,,/; �y emi �n er `� /�1 � J 1 Sprinkler � O ❑ O � Recreationai Bum Fire Alarm � ❑ ❑ ❑ � � � Hood Cleaning � ❑ ❑ ❑� Sprinkler System Installations Hood Suppression � p ❑ ❑� � Standpipes (Sprinkler Sys) � Fire Alarm Installation � Toroh RoofinglTar Kettle � Fire Pumps � Waste Tire Storage ANNUAL � Fire Works a Flammable Application- ANNUAL 2'3 � Valuation of Project Fuel Tanks Q Other: 0 �� 1 L za, � G o Contractor Company �S'��. � n � � t..` , Signature Registered N Fee Current Y/ N Address (�. Q�p a License # 26�c.� H'LO �� l t 9 ELECTRICIAN �� �� � � Sa�S � �'� —�� � � Company Signature � ) Registered Y/ N Fee Current Y/ N Address License # PLUMBER Company Signature Registered Y/ N Fee Current Y/ N Address License # MECHANICAL Company Signature Registered Y/ N Fee Current Y/ N Address License # OTHER Company Signature Registered Y/ N Fee Current Y/ N Address License # Directions: Fill out application completely. Owner & Contractor sign back of application, notarized (Or, copy of signed contract with owner) If over $2500, a Notice of Commencement is required (Mechanical work over $5000) Supply Mro (2) sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel #- obtained from Property Tax Notice (http:/lappraiser.pascogov.com) NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owne� has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the °Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. - CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specificatly included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafte� requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT (F.S. 117.03) OWNER OR AGENT CONTRACTOR Subscribed and swom to (or affirmed) before me this Subscribed and swom to (or affi before me this by bY Who is/are personally known to me or has/have produced Who is/are personally known to ' e o has/have p uced as identification. as identifica ' � l � J Notary Public Notary Public '. „ ,,,, JACQUELINE Commission No. Commissi� -•'i� EE 040520 �''• � �� m�,,,T�,,,w�eoo.ae��oto Name of Notary typed, printed or stamped Name of Nota Zephyrhills Fire Rescue 6�)07 Dairy Road, Gephyrhilis, f�L 33542 I�ire Marshal Bus (813) 780-0041 Kercy 13arnett l�a� (813} 780-UG44 E-mail: kbar�lett(��),tire.�ephyrhills.fl.us Plan Review #: 11-032 � Project: Fire Sprinkler Alteration Number of Pages: 1 plus 2 stapled pages April 6, 2011 I have received and reviewed the plan for the fire sprinkler alteration to be completed at 7954 Gall Bivd and will allow the project to move forward. By paying for permit, contractor acknowledges to comply with the items below. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. 1. Ensure any penetrations made are sealed to maintain the rated UL listing. 2. Ensure system is tagged once completed that work was performed in this space. Inspection Required: 1. Pressure Test 2. Final KERRY BARNET , [ E MARSHAL ***Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval ofthe submitted plans. it is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non-compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. � � z�����r��oL�.s Fi�� ���n►�TnnE� 6907 Dairy Road, Zephyrhills, FL 33542 F-ire Chiet Keii� Williams Bus (813)�80-0041 Fax (�13}78U-0044 FIRE SERVICE USER FEES Occupancy No.: � Plan No.: �� 2 Contractor: �,�i�,��� � %� /'i����' Business Name: f-itE ��s' Billing Address: ?i'� �oE�°�.� ���� BusinessAddress: ����6,�// �*y,�:� �.sit.sS�-, �. �3s��� Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contaet: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE AIARM FEE 8 Stte Plan N/C Annual N/C Sprinkler � 50 1 st Alarm N/C Multi .06 Sf 1 st Re-inspection N/C Standpipes $ 2nd Alarm N/C (Minimum Charge $25.00 2nd Re-inspection $100 Fire Pump $50 3rd Alarm N/C � Plan Revisions DBL 3rd Re-inspection $250 Hoods $50 4th Alarm $100 4th Re-Inspeetion $500 Fire Alarm $50 Sth Alartn $150 SPRINKLER SYSTEMS (Business closed until LP Gas �50 6th Alarm $200 0- 25 H28dS a$� VtO�IW1S COff@Cf@d� Natural Gas �JO NON COMPLIANCE $1$� 26 plus Heads � SPRINKLER SYSTEMS Fuel Tar1kS- Per tank $50 STANDPIPE SYSTEM Hydro Undergrounds �45 Sparklers $100 � Per Riser $50 Nydrostatic Test Per System Fire Works $500 FIRE PUMP Acceptance Test �� pe� sys��, Camp Fire $25 � Per Pump at00 Hydrant Flow $75 CoMrolled Bum $100 FIRE ALARM SYSTEM Hood/Duct $50 a 0- 25 DeviCes a50 FIRE ALARM SYSTEM P18Ce Of Assembly $50 An�ual 26 plus Devices $100 System Acceptance S50 Fire Protection $25 SUPPRESSION SYSTEMS Rec�711 ACCeptance $5a Flammable Application �50 Annual Wet $50 OTHER Waste Tire Storage �SSO Annual Dry $50 Fire WatUSmoke Wall $15 per wau Generator < KW $100 CO2 $50 LP Gas $25 �� e��k Generator >30 KW 150 Other �50 Natural Gas y25 Per sy5e�m BiaHazard Waste $100 Annual KITCHEN EXHAUST Fumigation Tenting $50 � Hood/Ducts $50 TeM 10'x10' or greater $15 per tent Torch Pot/Applied a50 OTHER Fire Pump a45 Haz. Materials a100 ann�si LP Inslallation per tank $50 Fire Suppression a30 Fuel Tank Installation a50 System Acceptance ❑ (Per Tank) $50 8 Exhaust Hood/Duct $30 Natural Gas Installation $50 Re-inspection DBL (Per System) (otherthan annual) � Spray Booth $50 � Inspection scheduled OBL 8 � and cancelled less than 24 hours Construction Insp. N/C Emergency VehiGe Ac� $50 FALSE ALARM PLANS TOTAL � INSPECTION TOTAL �� PERMIT TOTAL �� TOTAL r___ _I GRAND TOTAL a� �r ' Comments: Date: �� �� InsA��ctor: _�'t � r � c R�NTLINE lRE P1�QTECTI4N, INC. April 12, 2011 To Whom It May Concern This letter provides written authorization for Becky Glanz, of Frontline Fire Protection, Inc , to apply for and obtain fire sprinkler permits throughout the State of Florida on behalf of Douglas P. Glanz, the state license holder In addition, he is authorized to handle license renewal and registration for Frontline Fire Protection, Inc. and Douglas P. Glanz ... state certification number 26614200011993 expiring on 6/30/2012 �. Signe . Date. � � Lt - �( Dougla 1 Preside JOHN B DWYER, JR STATE OF FLORIDA ��y COMMISSION # DD988149 COLJNTY OF HILLSBOROUGH � EXP�RES JUN 17 2014 ��p�,� iONDED THROUGH RU piSUMNCE �MPANY BEFORE ME, T'HIS 12TH D Y F A , 1 l, DOUGLAS P. GLANZ APPEARED BEFORE ME, B ERS LY KNOWN TO ME. NOTARY P IC - STA E FLORIDA 10790 Florence Ave. - Thonotosassa, FL - 33592 -(813) 986-4556 fax.(813} 986-4546 LOBE FIREMIUMMM XMMMnON QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT •PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL DESCRIPTIONAND OPERATION CONVENTIONAL (OLD STYLE) The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it . can be installed wherever standardspray sprinklers are specified when c allowed by the applicable standards•It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, » 4 temperature ratings and finishes to meet many varying design require- ments. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating QUICK RESPONSE assembly is a hermetically sealed frangible glass ampule that contains UPRIGHT CONVENTIONAL a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At then °` prescribed temperaturethe internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. The sprinkler and escutcheon are not factory assembled. As- sembly is done in the field. TECHNICAL DATA QUICK RESPONSE • See reverse Side for ovalsandS PENDENT VERTICAL Appr peaftcatlonS. • Temperature Ratings -135 °F (57 0 F (68 0 F (79 0C), S 200 ° F(93 ° C),286 °F(141 °C). • Water Working Pressure Rating -175 psi (12 Bars). • Factory tested hydrostatically to 500 psi (34 Bars). • Maximum low temperature glass bulb rating is-67T (- 55 0 C). • Frame-bronze • Deflector-brass • Screw - brass • Bulb seat - copper • Spring - nickel alloy • Seal - teflon • Bulb - glasswith alcohol based solution, 3mm size. QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLER TEMPERATURE RATING /CLASSIFIC and COLOR CODT CLASSIFICATION AVAILABLE SPRINKLER N.F.PA. MAXIMUM TEMPERATURES . . CEILING TEMPERATURE • . N rat 5 INTERMEDIATE Y ��° HIGH �; 4 4077AIRPARKDRIVE, STANDISH, MICHIGAN 48658 DECEMBER 2006 ,4_20 989. 8464583 • FAX 989 - 846-9231 BULLETIN GL5615, REV #6 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT • PENDENT • VERTICAL SIDEWALL HORIZONTAL SIDEWALL • CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (39 metric) 12" NPT 2 1/4" (5 7 cm) Factory Bronze 4.2 (59 metric) 12" NPT 2 1/4" (5 7 cm) Satin Chrome Z NYC -DOB MODEL Bright Chrome 5.6 (80 metric) 12" NPT 2 1/4" (5.7 cm) White Polyester 3 7.8 (111 metric) 12" NPT 2 1/4" (5 7 cm) Black Polyester 3 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) I Lead Coated 2 NOTE METRIC CONVERSIONS ARE APPROXIMATE 'HORIZONTAL SIDEWALL IS 2 9115' FINISHES AVAILABLE ON SPECIAL ORDER- ' AVAILABLE AS cULus LISTED CORROSION APPROVALS RESISTANT WHEN SPECIFIED ON ORDER STYLE SIN K 135'F 156'F 175'F 200'F 286'F CuLus F.M. LPC CE NYC -DOB MODEL FACTOR 67 68'C 78'C 83'C 141'C N EA 101-92 -E GL2815 2.8 X X X X X X — — — X GL4215 4.2 X X X X X X — — — X UPRIGHT GL5615 5.6 X X X X X X X X X X OL8115 7.8' X X X X X X X — — X GL8118 8.1 X X X X X X X X X X OL28M 2.8 X X X X X X — — — X GL4201 4.2 X X X X X X — — — X PENDENT GL5601 5.6 X X X X X X X X X X GL8101 7.8• X X X X X X X — — X GL8106 8.1 X X X X X X X X X X VERTICAL GL5632 5.6 X X X X X X X — — — SIDEV"LL GL8133 8.1 X X X X X X — — — — CL2 M6 2.8 X X X X X X — — — X HOROOML GL4226 4.2 X X X X X X — — — X SIDEWALL § GL5626 5,8 X X X X X X X — — X GL8127 8.1 X X X X X X — — — — CONVENTiONAt GL5624 5.6 X X X X X — — X X — (OLD STYLE) GL6125 8.1 X X X X X — — X X — HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" t VERTICAL SIDEWALL SPRINKLER cLILus LISTED FOR LIGHT HAZARD ONLY PENDENT VERTICAL SIDEWALL cULus LISTED FOR 5 MIN. SPACING UPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9 MIN. SPACING ORDERING�NFORMATION •1n ° NPT SPECIFY • Quantity • Model Number • Style • Orifice • Thread Sizes • Temperature • Finishes desired • Quantity - Wrenches - P/N 325390 (1/2 "), P/N 312366 (L.0) t' `� s COMP'ORtAITON GwBe P RODUCT W ARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in mate- rial or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989 - 846 -4583 1- 800-248 -0278 FAX 989 - 846 -9231 www globesprinkler com DECEMBER 2006 PRINTED U S A. BULLETIN GI-5615, REV #6 GENERAL NOTES DQSTING SPRD&LER PIPE HANGER VMIN 24' (ISPRD KLER t A CIF REQUIRED) STRUCTURED T[�� I —..0 � NEV 1' AI7MQVER +47ti1,t `,11� 3,t44iwjnt FIRE SPRINKLER ARMOVER DETAIL (SEMI— RECESSED) BAR JOIST TOP DCM1 CLAP ALL THREAD ROD HANWR RING HANGER N0, I TOP BEAM CLAMP TYPICAL HANGER DETAILS 1 — ALL DESIGN, INSTALLATION AND MATERIALS SHALL BE AS PER NFPA -13 AND ALL RELATED CODES UTILIZED BY THE AUTHORITY HAVING JURISDICTION. 2 — IN THE PREPARATION OF THESE PLANS, THE DESIGNER HAS USED CERTAIN ABBREVIATIONS, CONVENTIONS, AND SYMBOLS, THE MEANING WHICH ARE ILLUSTRATED AND EXPLAINED WITHIN THE LEGEND. 3 — MATERIALS WELDED PIPING TO BE IN ACCORDANCE WITH THE LATEST EDITION OF NFPA -13 AND AWS D 10.9, LBEL A4 -3. NO SITE WELDING. FIELD VERIFY PIPE ROUTING AND CUT LENGTHS PRIOR TO FAERICATION OR INSTALLATION. ABCVE GROUND PIPE (ASTM A- 120 -55) A) I TO 1 1/2 ... BLACK STEEL, SCH.40 /DYNATHREAD B) 2" TO 6" ... BLACK STEEL, SCH.10 /DYNAFLOW FITTINGS FOR 1 " TO 2" TO BE BLACK CAST IRON AND /OR MALLEABLE IRON, RATED FOR 175 PSI WORKING PRESSURE. FITTINGS FOR 2" TO 6" TO BE GROOVED, FLANGED, OR WELDED AND RATED FOR 175 PSI WORKING PRESSURE. HANGER MATERIAL TO BE LISTED FOR FIRE SPRINKLER SYSTEMS. 4 — SPRINKLER CONTRACTOR TO PROVIDE : A) 200 PSI HYDROSTATIC TEST OF PIPING FOR 2 HRS. B) COPY OF MATERIAL AND TEST CERTIFICATE, WARRANTY AND INSTRUCTIONS TO THE OWNER. 5 — A NOMINAL NUMBER OF SPRINKLERS MAY BE NEEDED TO CORRECT OBSTRUCTED CONDITIONS DUE TO HVAC DUCTS OR OTHER EQUIPMENT INSTALLATIONS. THE CONTRACTOR SHALL ADD HEADS AS REQUIRED WITH ALL CHANGE ORDERS SIGNED BY GENERAL CONTRACTOR. 6 — SPRINKLER SPACING PER NFPA 13 ... SPRINKLER STYLE PER OWNER & ARCHITECT. SPRINKLER PIPING SHALL NOT PASS OVER ANY ELECTRICAL PANEL OR SWITCHBOARDS. COORDINATE WITH OTHER TRADES (INCLUDING MECHANICAL, PLUMBING, ELECTRICAL, STRUCTURAL, AND ARCHITECTURAL) FOR AVAILABLE SPACE AND INSTALLATION REQUIREMENTS PRIOR TO COMMENCING FABRICATION AND CONSTRUCTION. BEFORE ANY SPRINKLER PIPING IS CONCEALED, THE SPRINKLER CONTRACTOR SHALL NOTIFY THE AUTHORITY HAVING JURISDICTION , SO THAT THEY MAY INSPECT THE SYSTEM PIPING FOR CONFORMANCE WITH CODE REQUIREMENTS. 7 — ALL PIPING PENETRATIONS THRU ANY FIRE RATED ASSEMBLY SHALL BE MADE AND SEALED IN ACCORDANCE WITH A UL LISTED SYSTEM. THE PENETRATION SHALL BE FIRE SEALED IN ACCORDANCE WITH S.B.C.C.I. STANDARD BUILDING CODE, CHAPTER 10 USING A UL LJSTED SYSTEM FROM THE 1993 UL FIRE RESISTANCE DIRECTORY, AND PER LOCAL AUTHORITY HAVING JURISDICTION. 8 - EXISTING SPRINKLER SYSTEM IS HYDRAULICALLY CALCULATED FOR ORDINARY HAZARD GROUP 2- MERCANTILE OCCUPANCY NEW TENANT OCCUPANCY IS UGHT HAZARD AND ORDINARY GROUP 1 Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compli,�nce with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of 171 compliance, it shall be the contractor's sole responsibility, at thek sole expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure to be in compliance with all applicable NFPA Codes and local ordinances. `iUBMI171;D PLAN E BEN UvIE 3Y LEPHYRIULL. I RSF01, Da te:_____ , - .___ -- 1 FT SCOPE OF WORK: ADD OR RELOCATE 30 SPRINKLERS FOR PROPER COVERAGE BELOW CEILINGS IN RENOVATED SPACE I j 1 SPRINKLER PIPING PLAN = EXISTING PIPING = NEW PIPING Bldg. CM0• I- BEAMS, BAR JOIST Design Data ® Wet ❑ Dry ❑ Pre - Action Area 2 ,744± SQUARE FEET Roof METAL DECK Hazard LIGHT Sq. Ft. /Hd. 225 SQ. FT. M AX. Hose -- Denisity __ Area waits CONCRETE BLOCK & METAL STUD Contract With HAWKEYE CONSTRUCTION Flow Test Data BY Floor' CONCRETE Date __ Static __ Res GPM Job No. 742 lug. Ua RESTAURANT Sprinklers Revisions Syrn Mod & Type Orif Temp K- Factor Qty. SYM Installation Notes No. Date Description R RELOCATED CHROME PENDENT 1/2 165' O 5.6 20 ­7 t— NFPA HANGER LOCATION N NEW CHROME PENDENT 1/2 LINO 5.6 10 GROOVE COUPLING LOCATION A.F.F. ABOVE FINISHED FLOOR Q HYDRAULIC REFERENCE POINT ALL HEADS = QUICK RESPONSE Total 30 FI VE GUYS 7954 GALL BOULEVARD ZEPHYRHILLS, FLORIDA 33541 Date: 2 -10 -11 Survey B : Drawn By : B. E. Thompson Approval By : Fire Marshal . Degree Of Sprinklers 165' 1 212' 1 286' This Sheet 30 Total On Contract 30 Scale: 1/4 " =1' -0 uno Dwg. No. 1 OF 1 Q ®IV1.INE 10790 FLORENCE AVENUE THONOTOSASSA, FL. 33592 F W PROTECnONs JW� office: 813 - 955 -MM / fdx 813 - 9864346 email address: frontlinefirefgenaiLcorn