11-12665
,�-' CITY OF ZEPHYRHILLS 5335 - 8TH STREET (si3)�so-oo20 12665 " BUILDING PERMIT Permit Number: 12665 Address: 5131 GALL BLVD Permit Type: COMMERCIAL ZEPHYRHILLS, FL. Class of Work: ADD/ALT COMMERCIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 11-26-21-0010-18500-0030 Improv. Cost: 23,000.00 Date Issued: 12/30/2011 Name: BBHARTI INVESTMENTS INC Total Fees: 618.60 Address: 2151 SOUTHERN OAKS LN � Amount Paid: 618.60 LAKELAND FL 33813 Date Paid: 12/30/2011 Phone: (863)409-6422 Work Desc: INTERIOR REMODEL FOR STORE 5. • OWNER PLUMBING FEE 60.00 MECHANICAL FEE 60.00 OWNER FIRE PLAN REVIEW FEES 213.60 OWNER , � � ��� � � � FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c) when extra inspection trips are necessary due to any one of the following reasons: a) wrong address b) condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d) work not ready for inspection when called e) permit not posted on job site � plans not at job site g) work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before rewrding your notice of commencement." Complete Plans, Specifications Must Accompany Application. All work shall be performed in accordance with Ci . Codes and Ordinances. NO OCCUPANCY BEFO C.O. ; �• ,� CO CT SIGNATURE PERMIT OFFI R PE IT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER a �� � «� s "e� City of Zephyrhills BUILDING PLAN REVIEW CONIMENTS Contracto �1T�omeown : � � � � �-' _ � Date Received: �� r� � Site: `���� ���.����b '� '� ,�--- y ,, / � Permit Type: �� � �?�1� ��.��-C..�s. G/ ����i�g Approved w/no comments: ❑ Approved w/the below comments: l,� Denied w/the below comments: ❑ i� 1� ��� � �- ��� c � , � � �� ���,.,J . f"�� f � �,��;��.�+SS�_ / bT f��°�.�5 �11�' ll l_� ,, ; 6' ` % - t' l -C���'!� (� � r� C ' f � �� �b i �r /;J r�t G � � (� , � �r �1 � , C l� .:r �t.g l , �� � � ( d 4�'��/� �� v�- (� �� � �� � �" 4 � C C� � G' c/' � (�l / i!�e'lc l� This comment sheet shall be kept with the permit and/or plan � ' � A � / �� `� Bill urges Building Official Date Contractor and/or Homeowner (Required when comments are present) . s�H IIIIIIIilllll11111111111111111111111111111 201izeie6a • �� Rept:1406766 Rec: 10.00 D5: 0.00 IT: 0.00 12/30/il C. Cook, Opty Clerk NOTICE OF COMII�NCEMEIVT PRULR S 0'NEIL,Ph D PfiSGO CLERK & COMPTROLLER 12�30�11 8639 P � ° 3858 OR BK Permit No. Property Identification No. �-� � � a � 6 ��� �w r v�� f—T TI-IE TJNDERSIGNED hereby give informs you that the improvement wil] be made ta certain real pruPerly� and m au°Tdance with ` �/- , Scccion 713.13 of the Florida Statutes, the following infarmetion is provi ed in thie NOTICE OF CO �MLNT• � � �' � lUV VJ� �1�J ��_ ZG_ — p��o�) �S°o- c�v3v SpS� �`^ � �to�+�.�2a 1.Description of properry (lega/ descrlPtlon:J / a) Street Address: �. 2.Oeneral description of improvements: 3.Owner Infotmation �! �' ��yU BQ�'CQ � k+Q a) Name and eddress: b} Neme and address of fee simple titleholder (if other then owner) " c) Inurest m proPerty 4.Contractor Information a) Name and address: b) Telephone No.. Fax No. (Opt) S.Surcty 3nformation y a) Name and address: b) Amount of Bond: c) Telephone No.: Fax No. (Opt) 6.Leader � a) Name and address: Phone No. 7. Identity of person within the State of Flor'da d i ted by owaer uRon whom no 'ces or other d ts ay be served: a) Name and address: � Fax No. (Opt) " �(� b) Telephone No.: 8.In addirion to himself, owner designetes the ` 1lowin pe:son w receive a copy of the Lienor's Notice as pmvided in S�'on � i 3 i3 (1)N) �'iotiaa scannes: �j ���. '�q� 2� S � s�'" 1►^Q,,�•" �'1 �., I,a i"P o�� � a) Name and addrws: � b) Telephone No.: � ^ � Fax No. (Opt.) '� 9.Expiration date of Notice of Commencement (the expitarion dau is one year from the date of rewrding unless a different date �s specified}: WAItNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER APTER THE EXPIRATION_OF'THE NOTICE OF COMMENCEMENT ARE CONSIDERED IIVIPROPER PAYMENTS UNUER CAAPTER 713, PART I, SEC1'ION 713.13, FLORIDA STATUTES, AND CAN RESULT W YOUR PAYIING TWICE FOR DVIYROVEMENTS TO YOUR PROPERTY. A NOTICE OF COIVIMENCEMENT MUST BE RECORDED AND POSfED ON THE JOB S1TE BEFORE THE FIRS7' Q z U a DVSPECTION. IF YOU WTLND TO OBTAIIH FINANCIIVG+ CONSULT YOUR LE R OR AN ATCORNEY BEFORE COMMENCING WORK OR RECORDIIYG YOUR NOTICE OF COMIVIENCEME ,p z��= a W � srw ., y � V �� � F . co���W!R�s�JACQUELINEBOGES s��m�oro�m �.�aos�« � I�e.�Mtm.sQ o` � a x° � �' � ,',: '• ' ' . � • •::_ Commission # EE 040520 „� � d ^�—' f ��-, � = z J � `—� q ��.�. - — '_,�..:,�: Ex res December 12, 2014 �y �� �. Q � {, . K •. ; � PrintNeme � J; .��-�� �`� BoMed7TwTroyFainNauance8003657019 LL � () (j :.,.`�"^:�::�,. �_ dey of �C�r 20� by Z w O O fore oin t wes a ow e ore me this = � o�y g B (type of authority, ag. officer, trustee, attorney > 1- }� u.. ' iS� ���— 89 O 1— a� � in fact) or (neme of party on behalf of om inslrume� was exacuted)• C:.)=a W Personally Known /` OR Produced Ideatification _ No�Y SxB�� �~~-� Q U � � U m p � �F-�--�dZ O_i xame (princ) C�. rl� �3 D. O���= a w" Type of Identification Produced J W O p n�' � U U � � O V erificarion pursuent to Section 92.525, Florida Statutes. Under penalties of perjury. I declare that I have tead the foreBoing 8°d that O�� � c� �l c/� ill Cn Q _I W '�. the facts stated in it are truo to the best of my imowledge and belie£ Q��� z F-=�Z � � SigeMUre ofNae�rsl Pmon SiD�i'`�'O fn �- F-- �- a m FORMSMOC�M�OQ7 s�s-7so-oozo City of Zephyrhills Permit Application Fax-813-780-0021 Building Department �, J � Date Received / Phone Contact for P ittin `_ �-- - r , � .: :. --- .., Owner's Name "Ofnrner�hone Number Owner's Address � � V`Q- Owner Phone Number Fee Simple Titleholder Name Owner Phone Number � Fee Simple Titleholder Address JOB ADDRESS . LOT # �� SUBDIVISION . PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR 8 ADD/ALT 0 SIGN Q Q DEMOLISH INSTALL REPAIR PROPOSED USE Q SFR Q COMM Q OTHER TYPE OF CONSTRUCTION Q BLOCK Q FRAME � STEEL Q DESCRIPTION OF WORK � � � l C' � BUILDING SIZE � SQ FOOTAGE� HEIGHT � UILDING $ ��;j� �LU ON OF TOTAL CONSTRUCTION �'" � �ELECTRICAL $ � AMP SERVICE Q PROGRESS ENERGY Q W.R.E.C. �PLUMBING $ ` � _ �?•?C�_ L.._ - _~-___-�---�.__ QMECHANICAL $ VALUATION OF MECHANICAL INSTALU�� �ON �,livti�'%^ `� �__. ... �� �� � GAS ROOFING SPECIALTY aTHER ��!�� � 0 � 0 ��� FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA QYES NO I� � BUILDER COMPANY '" SIGNATURE � �� �GISTERED' � / N FEE RRE� Y/ N Address ' License # ELECTRICIAN � COMPANY SIGNATURE REGISTERED Y/ N FEE CURRE� Y/ N Address License # PLUMBER D ` COMPANY SIGNATURE REGISTERED Y/ N FEE CURRE� Y/ N Address License # MECHANICAL ��� COMPANY SIGNATURE REGISTERED Y/ N FEE CURREP Y/ N Address License # OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURRE� Y/ N Address License # RESIDENTIAL Attach (2) Plot Plans; (2) sets of Building Plans; (1) set of Energy FoRns; R-O-W Permit for new construction, Minimum ten (10) working days after submittal date. Required onsite, Construcaon Plans, Stormwater Plans w/ Silt Fence installed, Sanitary Facilities 8 1 dumpster; Site Work Pem►it for subdivisions/large projects COMMERCIAL Attach (3) complete sets of Building Plans plus a Life Safety Page; (1) set of Energy Forms. R-O-W Permit for new construcGon. Minimum ten (10) working days aRer submittal date. Required onsite, Construction Plans, Stormwater Plans wl Silt Fence installed, Sanitary FaciliUes 8 1 dumpster. Site Work Permit for all new projects. All commercial requirements must meet compliance SIGN PERMIT Attach (2) sets of Engineered Plans. `""*PROPERTY SURVEY required for all NEW construcUon. Directions: Fill out application completely. Owner 8 Contractor sign back of application, notarized If over 52500, a Notice of Commencement is required. (A/C upgrades over 57500) ** Agent (fo� the contractor) or Power of Attomey (for the owner) would be someone wfth notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs if shingles Sewers Service Upgrades A/C Fences (PIoUSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW DISCONNECT AND CAP -OFF WATER CLOSE' DRAIN & WATEI SUPPLY PIPING DISCONNECT AND CAP -OFF LAVATORY DRAIN & WATE SUPPLY PIPIN( RE- POSITION WATER CLOSE DRAIN & WATE SUPPLY PIPIN( PER FLOOR PL N o I 1 P RCV'IEW DATE_. C 1 Ty OF LFrPHYRtILLS PL, EXAMINER— `0 ALLVN'ORK - PREVAILING CODES, FLORIDA BUILDING CODE, NATIONAL ELECTRIC CODE AND CITY OF ZEPIIY RHi ,LS P.R.DINANCES Please be advised this review of plans submitted is a cursory review to assist the contractor in cprnpliranw with applicable fire s:3`eiy codes. This review is not intended to be a final apps) al col 1.he submitted plans. It is th contractor's sore �:� �'�� tv to ensure that the plans are in complete c01T —p!' , J) )1 applicable NFPA codes and local ordir .nc� s ; -?n' ii�at furti�� r examination or it ` na7 -cor of ance, it shall be the sole expense to Ge The City assumes no res. faaiil!ure to be in compliance - ours and focal ordinances. XJBMITTED PLAN(S) HAVE BEEN REVIL'WL ' JY ZEPIiYRHILLS FJAE 1ARS' AL'S OFFICE Date: —L, .2 r ��Wiewgc O x —_ w NEW STC DOUBLE ASSEMBI 1/4=11-011 ® ; FLECT D C ILING LAN r" � 1/4 = l'-O" GENERAL NOTES 1- GENERAL NOTES APPLY TO ALL ELECTRICAL DRAWINGS, UNO. 2 ELECTRICAL WORK SHALL BE PER THE FBC 2007 AND ALL ASSOCIATED ADDENDUMS, NATIONAL ELECTRICAL CODE 2008, LOCAL CODES AND ORDINANCES, CONNECTING UTILITY, MANUFACTURES INSTRUCTIONS, AND PROFESSIONAL WORK PRACTICES, AS REQUIRED FOR COMPLETE AND OPERATING SYSTEMS. NOTIFY OWNER OF ANY PROBLEMS PRIOR TO CONSTRUCTION. 120/208/3ph Phase A Black Phase B Blue Phase C Red Neutral White Bond Green 3 POWER, SERVICE, CONTROLS, DEVICES, EQUIPMENT, ETC SHALL BE CONSTRUCTED WHILE REUSING AS MUCH OF THE EXISTING MATERIALS AS POSSIBLE. 4- NEW MATERIALS SHALL BE NEW & IN GOOD CONDITION. WIRE SHALL BE STRANDED COPPER. TWH/TWN INSULATION SHALL BE 75 °C OR ABOVE. SERVICE CONDUIT AND TUBING SHALL BE PVC. OTHER CONDUIT SHALL BE RGS. WET WELL PIPING SHALL BE INTERNALLY COATED. 5- WIRE COUNTS, RUNNERS, GROUNDS, CABLE, BLOCKS, BOXES, CONNECTORS, CLAMPS, HANGERS, ETC ARE INSTALLERS RESPONSIBILITY. VERIFY CIRCUIT PROTECTION, WIRE AND CONDUIT SIZE, PHASES, AND EQUIPMENT LOADS PRIOR TO FEEDER CONSTRUCTION. 6- 3/4" x 10' COPPER CLAD DRIVEN GROUND RODS, MINIMUM 6-0" APART. GROUNDING CONDUCTOR SHALL BE NOA AWG FOR SERVICE CONDUCTORS SMALLER THAN 3/0 AWG. BOND GROUNDING CONDUCTOR TO ELECTRODE CONDUCTOR AT BOTTOM OF CONCRETE SLAB. CONTRACTOR SHALL MEASURE THE RESISTANCE OF INSTALLED GROUNDING ELECTRODES AND IF ABOVE NEC ARTICLE 250 ALLOWABLE VALUES, CONTRACTOR SHALL AUGMENT THE GROUND SYSTEM AS NECESSARY. 7 AVAILABLE SHORT CIRCUIT CURRENT RATING SHALL BE PROVIDED BY THE UTILITY. VERIFY THE MAIN BREAKER AND PRESENT SERIES RATED CIRCUIT BREAKERS ARE AIC RATED AT OR ABOVE THIS VALUE AND REPLACE IF REQUIRED. DRAWING NOTES 1. MODIFY, REFURBISH AND COMPLETE EXISTING ELECTRICAL SYSTEM. ELECTRICIAN TO PROVIDE POWER FROM THE NEW SERVICE THROUGH THE EXISTING PANELS AND ONTO THE INDICATED NEW RECEPTACLES. 2. SEE SHEET E -2 FOR HVAC EQUIPMENT, 3. INSTALLER IS TO VERIFY POWER AND BREAKER SIZE FOR ALL EQUIPMENT PRIOR TO CONSTRUCTION. CONSTRUCTION NOTES O SEE WALK -IN COOLER SHOP DRAWINGS FOR DOOR LIGHTS, DOOR HEATERS AND LOCATION OF POWER CONNECTIONS. O ALL KITCHEN AND PREP AREA RECEPTACLES SHALL BE GROUND -FAULT INTERRUPT TYPE. 1/4 = 1 1 -0 11 EXTG. METER TO BE REMOVED _LEC /ICE FROM EXTG, POLE TRANSFORMER Al EQUIPMENT & LIGHTING LAN 1/4 = 1 1 -0 11 BRACKET MOUNTED COMPRESSORS -- SEE MECHANICLA DRAWING MOUNT WATERPROOFGFI RECEP @ SAME ELEVATION AS COMPRESSORS PANEL "All W/ 42,000 AIC RATING SQ'D' TYPE RAINBOW 400 AMPS MBC 120/208 VOLTS 3 PHASE 4 -WIRE FOOD MART CKT BREAKER POLE DESCRIPTION LOAD PHASE LOAD DESCRIPTION POLE BREAKER CKT 1 20 1 LI GHTING - EXTERIOR 7.5 A 10.5 GENERAL RECEP 1 20 2 3 20 1 LIGHTING - EXTERIOR 5.0 B 13.5 SHOW WINDOW 1 20 4 5 20 1 LIGHTING 7.5 C 13.5 SHOW WINDOW 1 20 6 7 20 1 LIGHTING 3.8 A 13.5 SHOW WINDOW 1 20 8 9 20 1 LIGHTING 9.1 B 13.5 SHOW WINDOW 1 20 10 11 20 1 LIGHTING 9.1 C 13.5 SHOW WINDOW 1 20 12 13 20 1 LIGHTING 7.5 A 10.5 GENERAL RECEP - PREP 1 20 14 15 20 1 LIGHTING 12.0 B 3.0 GENERAL RECEP - OFFICE 1 20 16 17 20 1 SPARE 13 C 1.5 GENERAL RECEP - PREP 1 20 18 19 20 1 D20A -POS 0.5 A 7.5 GENERAL RECEP 1 20 20 21 20 1 D20B -POS 0.5 B 21.6 S4 -WATER HEATER 2 25 22 23 20 2 D28- MICROWAVE OVEN 12.5 C 21.6 2P 2 20 24 25 20 2 2P 12.5 A 6.0 GENERAL RECEP 1 20 26 27 20 2 D21- COOLATA 18.0 B 3.3 BAG -IN -BOX 1 20 28 29 SPACE 2 2P 18.0 C 6.6 SPARE 1 20 30 31 20 1 _ D57 -ICED TEA BRE 7.0 A 1.1 S1- SLICER 1 20 32 33 20 1 1 D24- UNDERCOUNTER REFRIG 6.5 B 30.0 SPARE 1 20 34 35 20 1 D 25- CARBONATED BEVERAGE 5.2 C 4.0 D30- UNDERCOUNTER FREEZER 1 20 36 37 20 1 D26- PASTRY CA 0.5 A 1.5 SPARE 1 20 38 39 20 1 D27- FAX/COPY w 7.0 B D41 SPARE 1 20 40 41 20 SLUSHIE SPARE C 30.0 EXIT LIGHTS 1 20 42 LTG = 139.5 AMPS E &R =163.3 AMPS LOAD DESCRIPTION CONNECTED LOAD (VA) DEMAND FACTOR DEMAND LOAD (VA) LIGHTING 16,740 1.25 20,925 RECEPTACLE 20,196 1 . 0 20,196 EQUIPMENT 40 1.0 D33 -BAGEL TO ASTER TOTAL A 12.5 41,121 TOTAL DEMAND CURRENT @ 120/208V - 3 PH. F 114 AMPS PANEL "B" W/ 42,000 AIC RATING SQ'D' TYPE RAINBOW 200 AMPS MBC 120/208 VOLTS 3 PHASE 4 -WIRE FOOD MART CKT BREAKER POLE DESCRIPTION LOAD PHASE LOAD DESCRIPTION POLE BREAKER CKT 1 40 1 D33 -BAGEL TO ASTER 40.0 A 12.5 D22 -FRESH ESPRESSO 1 20 2 3 2 1 v 2P 40.0 B 1 SPARE 4 20 4 5 20 1 D37 -SCALE 0.3 C 3.0 D38 -ATM 1 20 6 7 20 2 D39 -HOT DELI 11.6 A 11.6 D40 -HOT CHOCOLATE 2 20 8 9 CU -3 (EXTG) 2 2P 11.6 B 30.0 D42 - SLUSHIE 2 30 10 11 20 1 D3 - COFFEE GRIN 9.0 C 30.0 2P 2 13 12 13 20 1 D59- COMPUTER 1.5 A 1.0 D44- LOTTERY 1 20 14 15 20 1 D47 - INTERIOR SIG 4.0 B 14.4 D48 -HOT DOG ROLLER 1 20 16 17 20 1 D49 -N ACHO CHI WARMER 13 C 1.5 D60- COMPUTER 1 20 18 19 20 1 D51 - NACHO CHE ESE DISPENSER 10.0 A 16.5 D52 -SLIDE DOOR COOLER 2 20 20 21 20 2 D53 -SLIDE DOOR COOLER 16.5 B 16.5 2P 2 23 22 23 D31- COFFEE MACHINE 2 2P 16.5 C 13.8 D56- CAPPUCHINO 1 20 24 25 20 1 D55 -PIZZA WARMER 12.3 A 5.0 D58- EXTERIOR SIGNAGE 1 20 26 27 20 2 D54 -SLIDE DOOR COOLER 16.5 B D30 SPARE 28 20 28 29 SPACE 2 2P 16.5 C 6.6 D29 -ICE MACHINE 2 20 30 31 20 1 D61- SECURITY C AMERA 0.5 A 6.6 2P 2 33 32 33 20 2 D41- SELF -SE RVE DELI CASE 16.5 B 30.0 D50- YOGURT MACHINE (NL) 2 30 34 35 SPACE 2 2P 16.5 C 30.0 2P 2 37 36 37 20 1 GENERAL RECEP 3.0 A 1.5 GENERAL RECEP 1 20 38 39 20 1400 SPARE B D41 SPARE 40 20 40 41 20 SLUSHIE SPARE C 30.0 SPARE 42 20 42 (NL) "NOT LOCATED" ON POWER PLAN -- SEE OWNER LTG = 0 E & R = 474.6 AMPS PANEL " 200A MCB 120/208V -3 PH NEMA 1 NEMA 1 (4) - #3 THWN CU - (1) - #6 CU GROUND (1) - 1 -1/2" C. LOAD DESCRIPTION CONNECTED LOAD (VA) DEMAND FACTOR DEMAND LOAD (VA) RECEPTACLE 56,952 1.0 56,952 EQUIPMENT POLE 1.0 CKT TOTAL 60 2 56,952 TOTAL DEMAND CURRENT @ 120/208V - 3 PH. 158 AMPS PANEL „ PANEL "All 200A MCB 120/208V -3 PH NEMA 1 200A MCB 120/208V -3 PH. NEMA 1 30 8" X 8" TROUGH LJA FLOOR SLAB INTERIOR VIEW #1/0 CU GROUND PER NEC & LOCAL REQUIREMENTS 200A MCB 120/208V -3 PH NEMA 1 EN l� PANEL „C„ W/ 42,000 AIC RATING SQ'D' TYPE COMMON 200 AMPS MBC 120/208 VOLTS 3 PHASE 4 -WIRE CKT BREAKER POLE DESCRIPTION LOAD PHASE LOAD DESCRIPTION POLE BREAKER CKT 1 60 2 CU -1 (EXTG) 31.2 A 39.6 AHU -A (EXTG) 2 45 2 3 2 1 31.2 B 39.6 1 2 4 5 60 2 CU -2 (EXTG) 31.2 C 39.6 AHU -B (EXTG) 2 45 6 7 6 2 15.0 31.2 A 39.6 A 2 1 3.8 8 9 60 2 CU -3 (EXTG) 31.2 B 39.6 AHU -C (EXTG) 2 45 10 11 10 2 208 31.2 C 39.6 C: 2 120 12 13 60 2 CU -4 (EXTG) 31.2 A 39.6 AHU -D (EXTG) 2 45 14 15 14 2 POS 31.2 B 39.6 E3 2 POS 16 17 20 1 S2 -WALK IN COOLER 9.8 C SPARE 20 18 19 20 19 SPARE D22 A 1 500 SPARE 1 20 20 21 20 21 SPARE 7.0 B U /CTR FOOD PREP REFRIGERATOR SPACE 120 1 22 23 25 3 D31- COFFEE MACHINE 21.1 C D26 SPACE 60 120 24 25 24 3 3P 21.1 A SPACE MICROWAVE OVEN 3120 26 27 26 3 3P 21.1 B 2 SPACE D30 UNDERCOUNTER FREEZER 28 29 28 29 SPACE COFFEE MACHINE C 208 SPACE 21.1 D32 30 31 30 31 SPACE D33 A 6240 SPACE 2 40.0 32 33 32 33 SPACE B SPACE 34 35 34 35 SPACE 3 C D37 SPACE 30 120 36 37 36 37 SPACE A SPACE HOT DELI 2412 38 39 38 39 SPACE 1400 B 1 SPACE D41 SELF SERVE DELI 40 41 40 41 SPACE SLUSHIE C SPACE 30.0 EXIT LIGHTS 42 LTG = 0 E & R = 639.6 AMPS LOAD DESCRIPTION CONNECTED LOAD (VA) DEMAND FACTOR DEMAND LOAD (VA) EQUIPMENT 8,772 1.0 8772 HVAC 67,968 1.0 38,016 TOTAL 20 1 46,788 TOTAL DEMAND CURRENT @ 120/208V - 3 PH. [7 130 AMPS PANEL "D11 W/ 42,000 AIC RATING SQ'D' TYPE 200 AMPS MBC 120/208 VOLTS 3 PHASE 4 -WIRE CKT BREAKER POLE DESCRIPTION LOAD PHASE LOAD DESCRIPTION POLE BREAKER CKT 1 20 1 SPARE TOTAL A, 3.3 LIGHTING 1 20 2 3 20 1 SPARE 180 120 1 SPARE 1 20 4 5 20 1 SPARE 120 O 5.0 SPARE HYDRO CHILLER -.,Q (NL) 1800 6 7 15.0 D6 WATER METER (NL) 1656 A 1 1 3.8 D7 CONVECTION OVEN _ T2� (NL) 8 9 1 5 .0 D8 DECK OVEN (NL) B3 208 3 40.0 D9 10 11 208 3 3.6 D10 C: 180 120 1 1.5 12 13 5326 208 3 14.8 A BAG -N - BOX 396 120 1 14 15 POS 600 120 1 E3 D20B POS 600 120 16 17 C% D21 COOLATA MACHINE 3744 18 19 18. D22 FRESH EXPRESSO 1 500 A 1 12.5 D23 _ ICED COFFEE BREWER (NL) 20 21 7.0 D24 U /CTR FOOD PREP REFRIGERATOR B 120 1 6. D25 22 23 120 1 5.2 D26 C 60 120 1 0 24 25 120 1 A MICROWAVE OVEN 3120 208 2 26 27 ICE M ACHINE 1372 208 2 E3 D30 UNDERCOUNTER FREEZER 480 120 28 29 D31 COFFEE MACHINE 7600 208 C 21.1 D32 COFFEE GRINDER (NL) 1080 30 31 9.0 D33 BAGEL TOASTER 6240 Al 2 40.0 D34 32 33 D35 Ei D36 34 35 208 3 15.1 D37 C 30 120 1 0_3 36 37 Al HOT DELI 2412 208 2 38 39 HOT CHOCOLATE 1400 120 1 B D41 SELF SERVE DELI 1980 120 40 41 D42 SLUSHIE C 30.0 EXIT LIGHTS 1 20 42 LTG = 3.3 AMPS E &R= 23 AMPS NEW OVERHEAD ELECTRIC SERVICE RUN FROM EXISTING POLE TRANSFORMER AT REAR OF PROPERTY 0 z D J m (4) - 250 THWN CU (1) - 2 -1/2" C. EXISTING 600A K -BASE SAFETY SWITCH n GRADE #6 CU GND EXTERIOR VIEW EXISTING FEED THRU METEIR LOAD DESCRIPTION CONNECTED LOAD (VA) DEMAND FACTOR DEMAND LOAD (VA) LIGHTING 396 1.25 1 495 RECEPTACLE 3 WATTS PSF 1.0 2760 EQUIPMENT D2A 1.0 1800 TOTAL 1 15.0 3,255 TOTAL DEMAND CURRENT @ 120/208V - 3 PH. 9 AMPS EQUIPMENT SCHEDULE ITEM DESCRIPTION LOAD (VA) VOLTAGE POLE AMPS D1 MIXER - 140 QT. '-��, 4- (NL) 3454 208 3 9.6 D2A FRYER - �? jF_ (NL) 1800 120 1 15.0 D213 FRYER Fq T (2_� (NL) 1800 120 1 15.0 D3 DONUT MACHINE (2F (NL) 180 120 1 1.5 D4 PROOFER (NL) (TWO CONNECTION POINTS) 5824 208 1 28.0 600 120 1 5.0 D5 HYDRO CHILLER -.,Q (NL) 1800 120 1 15.0 D6 WATER METER (NL) 1656 120 1 1 3.8 D7 CONVECTION OVEN _ T2� (NL) 1800 208 1 5 .0 D8 DECK OVEN (NL) 14394 208 3 40.0 D9 AUTOMATIC SHEETER/CUTTER (NL) 1295 208 3 3.6 D10 POWER BASE (NL) 180 120 1 1.5 D11 WALK IN COOLER (NL) 5326 208 3 14.8 D12 BAG -N - BOX 396 120 1 3 D20A POS 600 120 1 5.0 D20B POS 600 120 1 5 D21 COOLATA MACHINE 3744 208 2 18. D22 FRESH EXPRESSO 1 500 120 1 12.5 D23 _ ICED COFFEE BREWER (NL) 7.0 D24 U /CTR FOOD PREP REFRIGERATOR 130 120 1 6. D25 CARBONATED BEVERAGE STATION 625 120 1 5.2 D26 DONUT DISPLAY CASE 60 120 1 0 D27 FAX/COPY MACHINE 120 1 D28 MICROWAVE OVEN 3120 208 2 15.0 D29 ICE M ACHINE 1372 208 2 6.6 D30 UNDERCOUNTER FREEZER 480 120 D31 COFFEE MACHINE 7600 208 3 21.1 D32 COFFEE GRINDER (NL) 1080 120 1 9.0 D33 BAGEL TOASTER 6240 208 2 40.0 D34 D35 D36 FOOD WARMER (NL) 5434 208 3 15.1 D37 SCALE (NL) 30 120 1 0_3 D38 ATM D39 HOT DELI 2412 208 2 11.6 - D40 HOT CHOCOLATE 1400 120 1 11.6 D41 SELF SERVE DELI 1980 120 1 16.5 D42 SLUSHIE 2 30.0 D43 COUNTERTOP ICE MACHINE (NL) 1212 120 1 10.1 D44 LOTTERY D45 MONEY TRANSFER (NL) D46 MONEY ORDER (NL) D47 INTERIOR SIGNAGE D48 HOT DOG ROLLER 1730 120 1 14.4 D49 NACHO CHIP DISPLAY/WARMER 155 120 1 1.3 D50 YOGURT MACHINE (NL) 208 2 30.0 D51 NACHO CHEESE DISPENSER 120 1 1 0.0 D52 SLIDE DOOR COOLER D53 SLIDE DOOR COOLER D54 SLIDE DOOR COOLER D55 PIZZA WARMER 1475 120 1 123 D56 CAPPUCHINO _ 1650 120 1 D57 ICED TEA BREWER __ _ __ 1 3,75 D58 EXTERIOR SIGNAGE D59 COMPUTER D60 COMPUTER D61 SECURITY CAMERA S1 SLICER 130 120 1 1.1 S2 WALK IN COOLER 1176 120 1 9.8 S4 WATER HEATER 9000 208 3 25.0 (NL) "NOT LOCATED" ON POWER PLAN -- SEE OWNER AIAz C� -'L) Aof-- NZ1' ov -) Pr AAQ F 1L M Afv_�_ TV rr'� LOAD SUMMARY @ 208V. - 3 PHASE PANEL kVA AMPS PANEL "A" 41,121 114 PANEL "B" 56,952 158 PANEL "C" 46,788 130 PANEL "D" 3,255 9 S N ( X N Ln 0') fl0 o _ 0-) o ft Y/ U n Qo E o U rp Cc U L C: _ T N x o E o � 3 U) E C V . �) O S N 1a „ T Z C) - $� 3 0 O Z W U E c jj 'n o u C .0 U 0 3 O U C) E ■ � O � x a o�- + U �c L w o ■ oc�` �cy-r_n ij as �Q) 0 CZ Co � 00 4J c , ) t� co ® w cz N 4-+ d 4J cri : '+ LZ U) Cz � � cd co � c , _j 00 U- C Lj u uj 0. N u _j Go _j 0 T CY) T _ LC) REVISIONS: DRAWN BY: JOHNNYFITZ CHECKED BY: DATE: 17 DEC 2011 SHEET EXISTING 1" CW SUPPLY FROM CITY WATER LINE GENERAL PLUMBING NOTES 1. THIS DESIGN MEETS OR EXCEEDS THE REQUIREMENTS OF THE 2004 FLORIDA BUILDING CODE - PLUMBING AND ALL WORK SHALL CONFORM TO SAME. 2. THIS DRAWING IS GENERALLY DIAGRAMMATIC AND IS NOT TO BE SCALED. REFER TO ARCHITECTURAL DRAWINGS FOR ACTUAL LOCATIONS OF FIXTURES. WHERE FIXTURE LOCATIONS ARE NOT SPECIFICALLY DETAILED, CONTRACTOR SHALL SUBMIT PREFERRED LAYOUT TO THE ARCHITECT PRIOR TO ROUGHING IN. 3. THIS TRADE MUST COORDINATE WORK WITH MECHANICAL, ELECTRICAL, FIRE PROTECTION, AND ARCHITECTURAL SYSTEMS TO AVOID CONFLICT AND DELAYS. 4. ALL WATER SERVICE PIPING IS TO BE INSTALLED OVERHEAD, UNLESS OTHERWISE NOTED, AND RUN PARALLEL TO EXTERIOR WALLS AND BEAMS. 5. NO EXTRAS WILL BE GRANTED FOR ANY PLUMBING CONTRACTOR FAILURE TO IDENTIFY EXISTING CONDITIONS, OR COORDINATE WITH OTHER TRADES, WHICH AFFECTS PROPER INSTALLATION AND /OR SUBSEQUENT REWORK. 6. EXISTING SANITARY PIPING IS SHOWN FOR REFERENCE ONLY WITH ALL NEW UNDERGROUND PIPING SHOWN TO BE SAWCUT BELOW THE SLAB AS REQUIRED. WHERE EXISTING SANITARY PIPING IS UNCOVERED AND DETERMINED TO BE APPROPRIATELY SIZED WITH ADEQUATE FALL AND IN GOOD CONDITION, ALTERNATE ROUTING WILL BE ACCEPTABLE WITH PRIOR APPROVAL. 7. ROUGH -IN LOCATIONS FOR ALL FIXTURES ARE TO BE MEASURED FROM FINISHED WALL SURFACES. VERIFY FURRED OUT WALL THICKNESS WITH ARCHITECTURAL DRAWINGS PRIOR TO FINAL ROUGH -IN. 8. ALL PLUMBING ROUGH -INS MUST BE COMPLETE, INSPECTED, AND APPROVED BEFORE REQUESTING FRAMING INSPECTION IN ACCORDANCE WITH 2004 FLORIDA BUILDING CODE SECTION 105.6. ACCORDINGLY, ROUGH -IN INSPECTION TO BE MADE AFTER THE ROOF, FRAMING, FIRE BLOCKING, AND BRACING ARE IN PLACE AND ALL SOIL, WASTE AND VENT PIPING IS COMPLETE, AND PRIOR TO THE INSTALLATION OF WALL OR CEILING MEMBRANES. UNDERGROUND INSPECTIONS TO BE MADE AFTER TRENCHES OR DITCHES ARE EXCAVATED, UNDERGROUND SYSTEMS INSTALLED, AND BEFORE ANY BACKFILL IS PUT IN PLACE. DRAWING NOTES 1. MODIFY EXISTING PIPING ROUGH -IN AND PARTIALLY COMPLETED PLUMBING TO INSTALL AND CONNECT UP NEW FIXTURES SHOWN. 2. PLUMBER TO INSTALL: (2) NEW RESTROOMS (1) JANITORS SINK (1) FLOOR SINK (1) HAND SINK (1) TRIPLE - COMPARTMENT SINK 3. SAWCUT, REMOVE & REPLACE CONCRETE FLOOR SLAB AS REQUIRED FOR NEW PLUMBING. CONSTRUCTION NOTES CD REMOVE EXISTING FLOOR DRAIN & TRAP. TIE NEW WASTER INTO EXISTING SEWER. O REMOVE EXISTING WATER CLOSET FLANGE. 2 CAP WASTE PIPE BELOW FLOOR. O CUT -OFF VENT AND CAP BELOW FLOOR O REMOVE FLOOR DRAIN. CAP WASTE PIPE BELOW FLOOR. O NEW 3" VENT STACK - EXTEND TO NEAREST VTR © REMOVE SINK OR (ROUGH -IN). CAP WASTE PIPING BELOW SLAB. CAP VENT ABOVE CEILING. O NEW 2" VENT STACK - EXTEND TO NEAREST VTR ® RE -ROUTE EXISTING VENT AS REQUIRED TO CLEAR 3 -COMP. SINK (NEW) WAST LUM ING LAN 1/4=1 CO XISTING ONN ECTION TO CITY SEWER - SEE CIVIL DWGS. �(7) o 0 °N Its �0)(-D O L ®! N U U CL Lo to t9 O U 00 CO o O L_ E a _c o a Q) 0 � 3 U) E L L �3 Z N T O cc 3 O 0 Z� o ri � � E N 10 z O ...__ cl o �o Q� 0 J < t' � t s O x o Z t m C C ■ ® 0 o o N o vO "a V(Y 2 _,_i � .� � Co U) � 00 ��� ` c: ®. �.� t ®� �® � � _ �co � ® c: cy) Lo _2 co U— w 0 z _j cD q4 'r— ift cy) REVISIONS: DRAWN BY: JOHNNYFITZ CHECKED BY: DATE: 15 DEC 2011 SHEET I EXTG 1 3" VTR I �J WC \> J (CAP) �FJ `� RE- VENTED VENT EXTG Z�J�i'i EXTG \ I�� NEW FD Pi nnR I �_ 3 -COMP NEW ' ' I 2" STACK NEVI VENT �I ��' NEW I We 3 \ LAV 3 r NEW SINK w � NEW 2" STACK —� VENT NEW 3" HUB DRAIN FOR COOL CONDENS) CC (:UNNtG 1 IUN TO CITY SEWER NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicabie deed restrictions. , UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and Iocal regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. if you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILiTIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Fu�thermore, ff Pasco County WateNSewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the "owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Applicatio� is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating constniction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health 8 Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone "V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to flll the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work fs commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT (F.S. 117.03) OWNER OR AGENT CONI'RAC70R Subscribed and swom to (or affirmed) before me thfs Subscribed and swom to (or affirmed) before me this by bY Who Is/are personally known to me or has/have produced Who Is/are personally known to me or hasJhave produced as IdentlficaHon. as identification. Notary Publlc Notary Public Commisslon No. Commission No. Name of Notary typed, printed or stamped Name of Notary typed, printed or stamped Zephyrhills Fire Rescue (,�>07 Dairy Road, Gephyrhills, FI. 335�}2 l�ire Mtirshal 13us (813} 7f�0-OU41 kerr� 1.3,�rnetl Faa (g I;) 78Q-OU=�4 " I_,-m��il: kbarnett(a;,tire.�ephyrhiVi�.tl.us Plan Review #: 11-140 Project: Interior Build-out Number of Pages• 8 December 20, 2011 1 have received and reviewed the plans for the interior build-out located at 5131 Gall Blvd (Rainbow Food Mart). At this time the project will be allowed to move forward. Paying for permit, the contractor agrees and will comply with the comments below. Should anyone have any questions, please do not hesitate to contact the Fire Marshal's office. 1. A lightweight truss sign shall be installed on the street side of the building in accordance to the statute. An "RF" sign is the one required. 2. Egress cannot be through a storage room. The exit sign by the handicap restroom can be removed. lt is not required. 3. There can be no storage in the upper level area (A/C area). [t is meant for mechanical only. 4 Secondary egress doors shall have panic hardware or a hotel latch. Only a single motion is al lowed. 5 Certified fire extinguishers shall be distributed around the store area so that travel distance is within 75 feet. Ensure extinguishers are in a highly visible area. 2A:I OBC are the required type of extinguishers. 6. There can be no storage within 3 feet of the electric panels (includes sides and front) in the rear storage. To help with this, paint a yellow box on the floor with hash lines through it. 7. The rear portion of this occupancy may become a 2" tenant in the future. Should that occur, a fire separation will be required between the two tenants. The separation (floor to ceiling) will most likely be a 2 hour separation. 8. Install a 30 minute rated door on 2" level entering the residential. This is to keep with the rating of the wall within the residential that faces the interior. lnspection(s) Required: 1. Final KERRY BARN T, �IRE MARSHAL ***Please be advised this review of plans submitted is a cursory review to assist the contractor in compliance with applicable fire safety codes. This review is not intended to be a final approval of the submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance with all applicable NFPA codes and local ordinances. In the event that further examination or site inspection reveals areas of non-compliance, it shall be the contractor's sole responsibility, at their sole expense to bring those areas in compliance. The City asswnes no responsibility for the contractor's failure to be in compliance with all applicable NFPA codes and local ordinances. ��,� ,; �"���iL��.� �IRE �EPA�TiVI'�M�� " 6907 �Jairy Road, �ephyrhiils, FL 33542 F�i�P t;;�iei �.eun �111iih�jrrt> Btas (S'i3}'��U-UO�i1 F�x (g1;3)I'di)-•UU�1� FIRE SERVICE USER FEES Occupancy No.: � ,�� ��� Plan No.: � d Contractor: , Business Name: �.i� i�cz� �✓��� Biiling Address: Q,¢,,� �� Business Address� cS%3/ t�'�'// 3 Business Phone No : Billing Phone No.: Business Fax No Billing Fax No.: Contact� Contact: �o -� — �py�_ PIAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE 8 Site Plan N/C Annual N/C Sprinkler S50 tst Alarm N/C Mult�•FamilylCommerc�a� 06 5( 1 st Re-inSpeCtion N/C Standpipes 350 2nd Alarm N!C ) (Minimum Charge E25 00 2nd Re-inspection E100 Fire Pump a50 3rd plarm NIC 1 a Plan Rewsions DBl 3rd Re-inspection �250 Hoods S50 dth Ala►m $100 � 4th Re-Inspection $500 Fire Alarm 350 5th Alarm $i 50 � SPRINKLER SYSTEMS (Business ctosed until LP Gas 350 6th Alarm g2pp 0- 25 Heads S50 violations corrected) Natural Gas ESO NON COMPLIANGE a 1 SO 26 plus Heads $100 SPRINKLER SYSTEMS Fuel Tanks- vertaok �$p STANOPIPE SYS7EM Hydro Undergrounds 345 Sparklers a100 � Per Riser S50 Hydrostatic Test S65 Pe� srscem Fire Works 5500 FIRE PUMP Acceptance Test E45 Per sys�em Camp Fire S25 � Per Pump 5100 Hydrerrt Fbw S75 CoMrolled Burn $t00 FIRE ALARM SYSTEM Hood/Duct $50 8 0- 25 Devices $50 FIRE ALARM SYSTEM Place of Assembly �SO Annual 26 plus Devices $100 System Acceptance $50 Fire Protection $25 SUPPRESSION SYSTEMS Recall Acceptance a50 Flammabie nppbcetion aSO Annual Wet $50 OTHER Waste Tire Storage S50 n„�o,i pry $50 fire WalUSmoke Wall 515 Pe� Wau Generato� < KW 5100 CO2 S50 LP Gas S25 per tank GellefetOr >30 K4V 150 Other E50 Natura! Gas 325 �� sn�M, Bio-Hazard Waste 3100 ��o��i KITCHEN EXHAUST Fumigation Tenting S50 � Hood/Ducts E50 TeM 10'x10' a greater S15 �r �i Twch Pof/Applied S50 OTHER Fire Pump b45 Haz. Materials a100 Annual LP Inslallalion per tank $50 Fire Suppression S30 Fuel Tank Installation 350 System Acceptance � (Per Tank) 350 8 Exhaust Hood/Duct S30 Nafwal Gas Insfallatton 350 Re-inspection DBL ( Per System ) (other than annual) � Spray Booth S50 � lnspection scheduled DBL 8 and cancelled less than 24 hours Construdion Insp. N/C Emergency Vehicle Ac� b50 FALSE ALARM PLANS TOTAIfi,��j��� INSPECTION TOTALr_ � PERMIT TOTAL� __ � TOTALI I � cT GRAND TOTAI � Comments Date i2��0 a�711 � Ins{���ctor YV � � �