HomeMy WebLinkAbout12-12931 CITY OF ZEPHYRHILLS 5335-STH STREET �si3)�so-oozo 12931 BUILDING PERMIT Permit Number: 12931 Address: 5202 17TH ST Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 11-26-21-0010-19700-0140 Improv. Cost: 41,000.00 Date Issued: 5/07/2012 Name: WORK FORCE HOUSING VENTURES IN Total Fees: 600.00 Address: P.O. BOX 948 Amount Paid: 600.00 DADE CITY, FL :33526-0948 Date Paid: 5/07/2012 Phone: Work Desc: REHABILITATION MAJOR INTERIOR/ EXTERIOR RG MCCARTY&SONS INC PLUMBING FEE 60.00 MECHANICAL FEE 60.00 MARCUM,TRACY INDIVIDUAL REROOF RESIDENTIAL 60.00 /'^ r -�1 �d , � 2�� 1� FOOTER BOND DUCTS INSULATED SEWER MISC._ ROUGH ELECTRIC LINTEL MISC MISC._ 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC._ DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC._ CONSTRUCTION POLE FRAME MISC. MISC._ REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80(2)(c) when extra inspection trips are necessary due to any one of the following reasons: a)wrong address b)condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d)work not ready for inspection when called e) permit not posted on job site f) plans not at job site g)work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your properly. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications Must Accompany Application.All work shall be pertormed in accordance with Ci Codes and Ordinances. NO OCCUPANCY BEFO C.O. ti;'� v? CON CTOR I NATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER CITY OF �/ / / / BUILDINa ZEPHYRHILLS DEPARTMENT � ,��5 � OF ADDITION OR CORRECTION � �%�° - �r,� ���1 . � � � � ,� `V qppRE� DATE PERMIT�, 2b2.- �7� � �L 2 �� �;, � � THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be rnade before tha job will be accepted. � � � 'y�t � ' L� �4� ��j � t.--<<-fi�`7'ti.k7 � �'`�-1tt� � (� vl�-j�1/��., ' .�1� � �, � " �L� � 1<<-�h) '�' 97 °°�S � tL� �--'� 11�� " � �'�,�'l�� 1'LJ�1t%L � ��n h � C(D 125 � � � ��t„ � � ���- I��l'►r�4 Z� r���c.� O���t�J� ) �t is unlawFul for any Carpenter,Contractor,eui�der,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the worlc with flooring,lath,earth 780- FOR RE-INSPECTION or other material,until the proper inspector has had ample time to approve the installation. r' OFFICE HOURS 7:30 AM-5 PM MON.-FRI INSPECTOR .� � 813-780-U020 City of Zephyrhills Permit Application Fax-813-780-0021 ' Building Department Date Received �. _/ �� ►'/, � __ �� �� ! � Phone ConWCt for Permittin� � r i � rrrr - � i r r9--r`rY" Owner's Name 1,�,�� Y Owner Phone Number Owners Address Q �Q Owner Phone Number � Fee Simple Titleholder Name Owner Phone Number � Fee Simple Titleholder Address � JOB ADDRESS �G.V� �� �L 2 LOT# [I� -�� SUBDIVISION �� �f Z h PARCEL ID# �I � - �- WI V' I ' d�� (08TAINED FROM PROPERTY TAX NOTICE) WORKPROPOSED rvEwcONS7a� ADDlALT � SIGN Q Q DEMOLISH INSTALL REPAIR PROPOSED USE SFR Q COMM � OTHER � TYPE OFCONSTRUCTION BLOCK Q FRAME � STEE� Q �� DESCRIPTION OF WORK ��� I�U1f�1l��fi� � BUILDING SIZE S�FOOTAGE� HEIGHT � �BUILDING $� � n.ob VALUATION OF TOTAL CONSTRUCTION L �ELECTRICAL $ 'SS Oa AMP SERVICE � PROGRESS ENERGY � W.R.E.C. �PLUMBING $ 7,1�(,�.0O ��' ' V" •'�v'J 3� w� � � / i �MECHANICAL $ VALUATION OF MECHAN�CAL INSTALLATION t 9 SU,bv �GAS � ROOFING Q SPECIALTY � OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA QYES NO BUILDER /�� ��OMPANY S •C • SIA� 4J�1�'� 11J� I.S���, �' SIGNATURE REGISTEREO Y/ N FEE CURRE� Y/N Address 0 �• ���p License# l� '-t J f,. ELECTRICIAN ,//_ �J,/►_ �� ,,COMPANY •v� �� IC��(}�� � �,�� SIGNATURE f�`�� � REGISTERED Y 1 N FEE CURRE Y/N Address ��25 �$b 9 License# �2.00( ��� PLUMBER �/�/ �OMPANY SW 1��n ��U1Y�I�'������ SIGNATURE 4 L'� REGISTERED �Y/ N FEE CURRE� Y!N � Address �•b. .3 License# hr I � MECHANICAL �C� v` OMPANY �r�-;) u'��'Um SIGNATURE REGISTERED Y! N FEE CURRE� Y/N Address �'� �q License# �Jl�+���,�b� OTHER %/��//{_ �' OMPANY S. � S�C Y�O�`V C � SIGNATURE �(/ REGISTERED Y N FEE CURRE� Y/ Address d O✓�1'O Dr• � License# �w t J L Z I '3�j 5 � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � ��� RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Fortns;R-O-W Permit for new construction, � Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence inslalled, Sanitary Facilities 8 1 dumpster;Site Work Permit for subdivisionsllarge projects COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(t)set of Energy Forms.R-O-W Pertnit for new construction. Minimum ten(10)working days after submittal date Required onsite,Construction Plans,Stormwater Plans w/Silt Fence instalted, Sanitary Facilities&1 dumpster Sde Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY reqwred for all NEW construction. Directions: � Fill out appiication completely Owner&Contractor sign back of application,notarized If over 52500,a Notice of Commencement is required. (A/C upgredes over E7500) " Agent(for the contrador)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS� The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting priviNeges in Pasco County TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES The undersigne:d understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance nurciber 89-07 and 90-07, as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended)� If valuation of work is$2,500 00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law--Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are nGt limited to� - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland P�reas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative ServiceslEnvironmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I ceRify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shali be construed to be a license to proceed with the work and not as authority to violate,czncel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considere�d abandoned. WARNING TO OWNER: YOUR FAILU TO REC A NOTICE OF COMMENCEMENT RESULT IN YOUR PAYING TWICE FOR IMPROVEME PROPERTY. IF YOU INTEND TO OBTAI INANCING,CONSULT WITH YOUR LEND R A Y BEFOR CORDING YOUR NOTICE f COM NCEMENT. FLORIDA JURAT(F S 17 0 ) �r OWNER OR AGE CONTRACT � S s bed an byw i r �ed)ne�fJ1or�m�e thj� S�¢� b�d and y ry1ti affirmed)befo m this ScCI / �� —�os,ru h r►�u,�i.sscK o is! e pers all i o e or s/have produced Who ic/a p� <now or haslh e produced as ification a d tificatron. Notary Pubhc Notary Public commission No. �►�r�--pETi2ULLi mission No HRISTINA PETRULLi �`* ' � RY PI In� NOTARY PUBLIC Name of Notary typ �• r' s Name of Notary typed,printed or stamp� STA IDA �, �ATE OF FLORIDA a��m#EE04941� Comm#EE049411 v���e�0 Expiras 12/20I2014 'r�NCE 19�� Expires 12/20/2014 Pasco County Parcel: 11-26-21-0010-19700-0140 001 Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, March 24, 2012 Parcel ID i1-26-21-0010-19700-0140 (Card: 001 of 001) Classification 01 - Single Family Mailing Address Property Value WORK FORCE HOUSING VENTURES Ag Land $0 INC Land $24,318 PO BOX 948 Building $40,825 DADE CITY FL 33526-0948 Extra Features $331 Physical Address 5202 17TH ST )ust Value �65,474 ZEPHYRHILLS FL 33542-2121 Assessed (Non-Schooi Amendment 1) $65,474 L@adl D@SCCIDtIOIt (First 4 Lines) Taxable Value $65,474 See Plat for this Subdivision�'° CITY OF ZEPHYRHILLS PB 1 PG 54 LOTS 14-16 INCL BLOCK 197 OR 8432 PG 1763 Land Detail (Card: 001 of 001) Line Use Description Zoning Units Type Price Condition Value �1 0100 SFR OOR2 8,400.00 �F $2.72 1.00 $22,848 �2 0100 SFR OOR2 4,200.00 SF $0.35 1.00 $1,470 Additional Land Information Acres 0.29 Tax Area 30ZH FEMA Code �Residential Code ZHLHLP2 Buildina Information - Use 01 - Single Family Residential (Card: 001 of 001) Year Built 1955 Stories 1.0 Exterior Wall 1 Concrete or Cinder Block Exterior Wall 2 None Roof Structure Gable or Hip Roof Cover Asphalt or Composikion Shingle Interior Wall i Plywood Panel Interior Wall 2 Drywall Flooring 1 Asphalt Tile Flooring 2 None Fuel Electric Heat Forced Air- Ducted A/C Central Baths 2.0 Line Description Sq. Feet Repl. Cost New 1 B� 1,500 � $58,575 2 FOA 200 $1,953 3 UCP 228 � $1,328 Extra Features (Card: 001 of 001) � Line Description Year Units � Value 1 CLFENCE 1972 320 � $113 2 FIRE PL 1955 1 � $218 Sales History Previous Owner LASALLE BANK NATIONAL Year Month Book/Page Type Amount 2010 11 8499/ 1168 WD � $0 2010 08 8432/ 1763 WD � $59,400 � 2010 05 8335 /0761 �r $0 http://appraiser.pascogov.com/search/parcel.aspx?sec=11&twn=26&rng=21&sbb=0010&b... 3/27/2012 Permit No. Parcel ID No.11-26- -0010-19700-0140 NOTICE OF COMMENCEMENT State of FLORIDA County of PASCO THE UNDERSIGNED hereby gives notice that improvement will be made to ceRain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: • 1. Description of Property: Parcel Identification No.CIIY OF ZEPHYRHILIS.PB 1.PG 54.LOTS 1416 INCL.BI.00K 197 Street Address: 520217�'Stieet.Zeohvrhiils.FL 335d2 2. General Description of Improvement: Minor Rehab I IIIIII IIIII IIIII II�II IIIII I�IIIIIIII IIIII IIIII IIIII IIII IIII " 2012043854 _ 3. Owner Infortnation: Woricforce Housin�Ventures.Inc.,a Florida�ot for orofit corooration Name PA.Box 948 Dade Citv Zin Code 33526 F� Address City State Interest in Property: Fee Simcle Name of Fee Simple Titleholder. (If other than owner) Address City State 4. Contractor. S.C.Si�nature Construction Corn-Mark Conner/Joe Matissek Name 8539 Oreto Dmre Port Richev Zio Code-34668 FL Address City State Contractor"s Telephone No.: 727.842.5163 Fax No.: 727.474.0008 5. Surety: Name Address City State Amount of Bond: $ Telephone No.: Rept:1422205 Rec: 10.00 6. �ender. DS: 0.00 Name IT: 0.00 03i 16/12 J. Farxas, ng±.� �1�..,;; Address City State LendersTelephone No.: 7. Persons within the State of Florida designated by the owner upon whom no6ces or other documents may be served as provided by Sedion 713.13(1)(a)(7),Florida Statutes: Fasco Countv Communitv Qgvelooment Attn: Ed Pflieaer Name 5640 Main Street Tlew Port Richev Zio Code-34652 F� Address City State Telephone Number of Designated Person: 7�7.834.3445 8. In addition to himself,the ovmer designates Ed Rflieaer andlor Eric Fetrow of Pasoo Couniy Community Development 9. to receive a copy of the Lienors Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 727.834.3445 10. E�iration date of Notice of Commencement is one year from the date of recording unless a different date is spe�ed: WARidING TO OWNER: ANY PAYMENTS MADE BY TtiE OWNER AFTER THE EXPIRATiON OF TNE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMME ING W R RECORDIN OTI E OF COMMENCEMENT. STATE OF FLORI ,� �����. .`:�"'°�e'• KARIN M.LLOYD COUNTY OF PAS ,•?o� °�: . . _ Notary Public-State ol Florida Sign f Owner or Ow rs Auth OfficedDirectodPartneN!!4anager :,�,, o;; My Comm.Expires Nor 2,2014 `,�.,_� Commission N EE 39453 �(.�-[LV�- � +l" '•.'�E�;'�,;. Signatory's Tdle/Office The foregoing instrument was acknowledged before me fhiso�day of��20��--by ����� �• ��mp� as �XQCI�t ll2° �/►'�C�jl� (type of authority,e.g.,offioer,trustee,attorney in fad)for �vo rK-fvrcL Q U S I' �.Q I'1fUIZ°S /]C � (name of pa �bepalf of whom instrumen�/t was executed). Personally Known OR Produ Identification Notary Signature m� / C� Type of Identification Produoed Name(print) �r�r1 I'n• LtDy� Verification pursuant to Section 92.525,Florida Statutes. Under penatties of perjury, decl that 1 have rea regoing and that the facts stated in it ars true to the best of my knowledge and belief. PREPARED BY 8 RETURN TO: Pasoo County Community Development Signatu N ral Person Signin Above 5640MeinStre6t PAULA S 0'NEIL,Ph D PRSCO CLERK & COMPTROLLER New Port Richey,FL 34652 03/16/12 i l•27am 1 .._a�_�.r...._.:_.....�_..__..__... _�0�.0....._ OR BK ���� P�o��7T STATE 0� FLG�lC�a�, �C��;�TY�� �'ASC�i THIS ISTO CcR'��irY T�-i,�'�:i ";-'ts� r-OR�.��;iP�:�:: i�,^� TRUE AND i.O�REI,T l,t:�1=Y OF i i-!c= [)C�,i:Jtil�.��'-r ��- i:�. 4� � /-1�!'� � f �_iIC [' ON FILc OR G '��:..I� �t: ;.�� ,,�� �, I � WITNES��Y HAP�t)f,NG �:'rr=iGlN�c:���_TNi�. ��Y o� C� >oti"2..- -l�_ -C�------ �---_ P,qULA S O 3�drl!_ ;;I_L�KI< & CC�i�1iP'�RC'�L!_FR BY— f-��k�-`�— - t.�l: � ,��r K a�..� �� j.�, . ;- . PASCO COUNTY' FLORIDA � 1 ��mnn�nnniniin i m o��mninn il/ ���non � - �- ' DADE CITY (352)521-4274, Ext. 3445 PASCO COUNTY COMMUNITY � �� � ' LAND O' LAKES (813)996-7341 Ext. 3445 DEVELOPMENT DIVISION �`� � NEW PORT RICHEY (727)834-3445 5640 MAIN STREET,SUITE 200 ` . FAX (727)834-3450 NEW PORT RICHEY, FL 34652 � s "Bringing Opportunities.7�ome" REHABILITATIO�T ��OGRAM L 'SHALI,COMI'I,Y WITHALL PREVAILING COD�'S,FL�iRIDA BUILDING Rehabilitation Bid Pro osal for: Workforce Housin Vei��,,ln,�T p �— �Dn�-�nONAI.ELECTRIC CODEAND 5202 17th Street CITYOFZEPIf7'R�IILLS URI)TNANCES Zephvrhills, FL 33542 Case # 10-6456 Date Due: Februarv 24, 2012 Contractor's name: S.C. Signature Construction, Corp. ►��ViFMn� �,,,�_ Address: 8530 Oreto Dr. Port Riche FL 34668 � _ ' -�� PROPOSAL �1�IVS E�(AMf���ILL_S I, the undersigned contractor, having inspected the above referenced property; and having famiTia�-- myself with the requirement set forth in the work write-up, rehabilitation standards, and plans of the above-referenced; and I understand the extent and character of the work to be performed, propose to furnish all labor, equipment, and material to accomplish all work as described in the work write-up. INITIAL PROJECT TOTAL $ 41,000.00 ADDENDUM TOTAL $ TOTAL $ 41,000.00 OPTION #1 $ For the sum of Fortv-One Thousand dollars ($ 41,000.00 ), with an itemized breakdown on the attached work write-up,to form this proposal. If my bid is accepted, I will commence work within seven (7) calendar days after the Notice to Proceed is issued and will complete the work within Seventy Five (75) calendar days after the Notice to Proceed is issued. Indicate percentage amount that will be used for profit and overhead for allowance items only 20 %. COMMENTS: Authorized Signature Title NOTE: This sheet must be attached to work write-up with the itemized breakdowns written in their appropriate spaces in order for us to consider your bid. PLEASE NOTE: Pasco County Community Development Division will reject bids with inaccurate totals exceeding 2% and line items with no dollar amaunt. GDR/EFP/EF/gs '�asco County—�F'londa's premier county for 6aCanced economic growt(z, environmentaCsustaina6iCity, andfirst-cCass services." THE STANDARDS AND GUIDELINES SET IN BID SPECIFICATIONS 2011 i1NLESS OTHERWISE NOTED, ALL WORK IN THIS WRITF-UP TO FOLLOW SPEC # DESCRIPTION OF THE WORK LOCATION COST EXTERIOR WORK 28 ROOF SHEATHING Replace any rotted sheathing and/or sheathing inadequate for nailing roof covering materials. Sheathing to be '/2" CDX plywood This item is an allowance. Submit pictures of replaced sheathing. Exterior $100.00 37 EXTERIOR DOORS Replace existing front entry door with new. The door frame to be composite material and a 6 panel fiberglass door and lever lockset and dead bolt. Front Entry 450 Replace existing carport/interior entry door with new. The door frame to be composite material and a 6 panel fiberglass door and lever lockset and deadbolt. Carport/Interior 400 Replace existing back entry door with new. The door frame to be composite material and a 6 panel fiberglass door and lever lockset and deadbolt. Back Entiy 400 All doars to be keyed alike. All hardware and lever locks and deadbolts to be polished brass in color. Information Only 39 SCREEN - RESCREEN Install new dark charcoal fiberglass screen and proper spline. Mesh size to be 18/14. Include replacing missing or damaged screen frames. All Wind��ws 275 45 EXTERIOR SIDING—MASONRY FINISH Remove wood panels, clap boards, siding at back of house. Install %2" 4 ply CDX plywood and nailed 6" O.C. Provide and install wire lath. Provide and install stucco. Finish texture to be sand finish. Exterior 1500 Concrete block exterior masonry finish per specs. (Smooth, Spanish, or Other) See 2011 Bid Specs. Exterior Info Only PAGE TOTAL: 3125 CASE#: 10-6456 5202 17th St. DATE: 03/08/12 PAGE: #1 Rev.3/10/11 THE STANDARDS AND GUIDELINES SET IN BID SPECIFIC:ATIONS 2011 UNLESS OTHERWISE NOTED, ALL WORK IN THIS WRITF-UP TO FOLLOW SPEC # DESCRIPTION OF THE WORK LOCATION COST 49 GUTTERS AND DOWNSPOUTS Install new 6" seamless gutters and downspouts at all eaves where water runoff from the roof occurs. Leaders and downspouts to be 3"X 4" with splash blocks included in the price. White. Entire House 700 50/51 ROOFING-GENERAL SPECIFICATIONS ROOFING-FIBERGLASS SHINGLES Remove the existing roofing material and old felts. Replace any deteriorated wood framing and sheathing (see spec No. 28). Install a new 30 year dimensional shingle roof per all requirements of the specifications and applicable codes. Shingles to be Tamko Heritage 30 or equal. The secondary water barrier is peel and stick. Note: Existing lx2 drip board may be removed when new fascia& soffit is being installed. The contractor to submit the roofing inspection affidavit upon the completion of the project. Include installing ridge vents at all peaks. Re-nail the deck to meet code Entire House 3200 Contractor to notify the Housing Specialist at the time of roof installation so pictures, of the substrate and water barrier installation, can be taken to verify compliance of specifications. Failure to notify could result in the roofing being rejected. Info Onl;y Info Only 53 ROOFING-ROLL ROOFING Remove the existing roofing materials at dead level flat roof areas. Replace any deteriorated wood framing and sheathing. (See Spec. No. 28) Re-sheath and install new built-up roof per specifications. The secondary water barrier is peel and stick. Flashing installed as required to pitched roof areas. Re-nail the roof deck to code. Flat Roof 1400 Contractor to notify the Housing Specialist at the time of roof installation so pictures, of the substrate and water barrier installation, can be taken to verify compliance of specifications. Failure to notify could result in the roofing being rejected. Info Only Info Only PAGE 7'OTAL: 5300 CUM TOTAL: 8425 CASE #: 10-6456 5202 17`n St. DATE: 03/08/12 PAGE: #2 Rev.3/10/11 THE STANDARDS AND GUIDELINES SET IN BID SPECIFICATIONS 2011 LTNLESS OTHERWISE NOTED, ALL WORK IN THIS WRITE-UP TO FOLLOW SPEC # DESCRIPTION OF THE WORK LOCATION COST 55 WALL INSULATION In all new exterior walls, install insulation as required to achieve R-11 in frame. Florida Room 480 78 ELECTRICAL Install a new exterior, waterproof GFCI outlet. A/C Condenser 120 Furnish and install a new exterior light. Back& Front Entry/ Assume cost of fixture at $20.00. (3) Carport 140 Provide and install new breaker and proper wiring for new A/C unit locate where old unit had been. Exterior 195 Remove outlets, terminate electrical service. (2) One is on house at back porch other outlet is on 4" x 4" post in back yard. Exterior 50 Repair interior cover panel on break box, straighten out bent cover and re-attach cover to box. Exterior 50 See Interior spec. #78 for re-lamping information Information Only 80/81 PLUMBING-GENERAL SPECIFICATIONS PLUMBING FIXTURES Replace all existing hose bibs with new hose bibs and vacuum breakers to code. Include a new lever handle shut-off valve at water service entry. Exterior 128 84 FENCES Provide and install a new gate with latch. Exterior 120 Reattach fence to post. Exterior 60 PAGE TUTAL: 1343 CUM TO'TAL: 9768 CASE #: 10-6456 5202 17th St. DATE: 03/08/12 PAGE: #3 Rev.3/10/11 � THE STANDARDS AND GUIDELINES SET IN BID SPECIFICATIONS 2011 UNLESS OTHERWISE NOTED, ALL WORK IN THIS WRITE-UP TO FOLLOW SPEC # DESCRIPTION OF THE WORK LOCATION COST 87 PAINTING- GENERAL SPECIFICATIONS Pressure clean, scrape and prepare exterior for painting. Repair all cracks and holes. Remove all nails, brackets, screws, etc. Paint the entire exterior of the house and retaining walls, including all exposed wood, concrete, stucco, masonry and ferrous metal. All newly installed wood shall receive one coat of primer or undercoat and two coats of semi-gloss paint. Include the painting of fascia and soffit. Color to be elected by owner. Exteriar 1500 Pressure clean all back porch, carport, front porch. Info Only Info Only Paint back porch, carport, front porch with epoxy paint. Exterior 490 88 LANDSCAPING Install landscaping in the front yard as directed by the housing specialist. The allowance for this item. Front Yar•d $400.00 Cut and remove (11) indicated trees in yard. Labor and equipment to be provided by a properly insured, professional tree removal company. Include stump and visible root grinding. All trees will be marked with yellow tape at open house. Entire Yard 3000 90 MAIL BOX Furnish and install a new mail box to our bid specs. Exterior 85 94 MISCELLANEOUS Furnish and install new address numbers to code. Front 45 Remove 4 x 4 post in back yard include the fill of whole with clean fill dirt. Back Yar� 20 PAGE TOTAL: 5540 PROJECT EXTERIOR TOTAL: 15308 CASE #: 10-6456 5202 17th St. DATE: 03/OS/12 PAGE: #4 Rev.3/10/11 THE STANDARDS AND GUIDELINES SET IN BID SPECIFI(:ATIONS 2011 UNLESS OTHERWISE NOTED, ALL WORK IN THIS WRIT�+:-UP TO FOLLOW SPEC # DESCRIPTION OF THE WORK LOCATION COST INTERIOR WORK 19 FLOOR COVERING /CARPET After the removal of existing flooring, install new carpeting to manufactures instructions. The carpet shall be (30) ounce, stain resistant over a minimum of 1/2 inch re-bond, FHA approved. The installation shall be in an approved manner. All tack strips, metal accessories, etc., are included in this specification. The carpet shall be first quality, no seconds will be accepted. Product documentation will be provided by the contractor prior to installation. Included are all closets opening into newly Hall Closet/ carpeted areas. Bedrooms 900 22 FLOOR COVERING /CERAMIC Install new ceramic tile floor to manufactures recommendation. M. Bath Closet/ Assume cost of tile to be installed at $2.00 per sq. foot of area. Bathroorras 800 Note: Existing ceramic tile to remain, use caution. Information only 25 BASE & SHOE MOLDING Install new wood base and shoe molding on all walls. When new base is installed over flooring, no shoe is required. Trim to be colonial. Entire House 360 26 WALL FRAMING SPECIFICATIONS Remove wall between laundry and Florida room. Provide and install new 2"x 4" wall in same location as old one. Interior 510 Frame in opening in Florida Room wall and N. bedroom closet, include A/C duct in same closet. Remove window sill located in closet. Interior 220 36 WINDOW REPAIR Repair the existing windows to proper operating condition. This includes closers, springs, weather stripping, and sashes. Include replacing any broken glass panes. All Wind��ws 500 56 CEILING INSULATION Check existing ceiling insulation and add insulation as required to achieve an estimated R-30 (Minimum 10.375 ") in pitched roof areas. Contractor to post attic card on site. Second card to be supplied with final pay request. Entire House 370 PAGE TOTAL: 3660 CASE #: 10-6456 5202 17th St. DATE: 03/08/12 PAGE: #5 Rev.3/10/I 1 THE STANDARDS AND GUIDELINES SET IN BID SPECIFI(�ATIONS 2011 UNLESS OTHERWISE NOTED, ALL WORK IN THIS WRITE-UP TO FOLLOW SPEC # DESCRIPTION OF THE WORK LOCATION COST 56 WALL AND CEILING FINISH-REPAIR WORK(INTERIOR) Remove drop ceiling in the Living room, (2) Bedrooms include Closets, Hall Bathroom, M. Bedroom and Bath Closet. Provide and install new drywall on all effected areas. Info Only Remove all wood panels, clap boards off the walls in Living Room, Florida Room, M. Bath Closet, M. Bedroom Closet, Hallway and Hall Closet, S.W. Bedroom. Provide and install drywall in all effected areas. Include Florida Room and Laundry Room wall where it was re-framed and N. Bedroom closet where opening was framed up and A/C duct framed in. Info Only Remove all phone and co-axel boxes, patch all holes left from the removal of boxes. Info Onlv Repair all cracks and damaged surfaces to match existing. See Bid Specs 2011. Apply new skim coat to ceilings and walls before installing texture. Ceilings to have a heavy knock-down texture, walls to have orange peel texture. Note; all textures to be professionally applied through a spray texture machine, not a hand held hopper. Interior 3450 Include any damage caused from wall removals, surfaces and finishes. Include any additional damage caused by building modification, etc. in price. Info Only 63 INTERIOR WALL FINISH-CERAMIC TILE (THIN SET) Remove all existing ceramic tile on the walls. Furnish and install new Wonderboard surround at tub to ceiling. Install new ceramic tile. Assume "cost of the tile" at $2.00 per sq foot. Include the removal of all wall tile in price. Color/design to be selected by the Housing Specialist. Hall Bath 1000 64 FIXTURE SET Furnish and install a new ceramic fixture set. Color to be selected by the owner. Bathroorrns 80 67 ATTIC ACCESS Provide and install new trim around attic access. Trim to be colonial. Hallway 95 PAGE TUTAL: 4625 CUM TO'TAL: 8285 CASE #: 10-6456 5202 17th St. DATE: 03/08/12 PAGE: #6 Rev.3/10/11 THE STANDARDS AND GUIDELINES SET IN BID SPECIFICATIONS 2011 UNLESS OTHERWISE NOTED, ALL WORK IN THIS WRITF-UP TO FOLLOW SPEC # DESCRIPTION OF THE WORK LOCATION COST 69 INTERIOR DOORS Furnish and install panel bi-fold doors with track and hardware for the closets. M. Bath Closet, S.E. Bedroom Closet,N. Bedroom Closet, Pantry, M. Bedroom Closet. Colonial trim. Pantry/Cl�sets 760 Remove existing door trim. Provide and install new Colonial trim, door stop and lever lockset set. M. Bedroom S.W. Bedroom, Hall Closet, Hall Bathroom. Interior 680 Furnish and install a new hollow core paneled door, hinges and lever lockset set. (slab only)N. Bedroom, Florida Room, M. Bathroom. Remove existing trim, provide and install new Colonial trim. Interior 430 All hardware, hinges, lever locks to be Antique brass in color. Info Onlv Adjust all doors so they open, close and lock correctly. Info Only 74 CABINET MEDICINE Provide and install new wall mounted mirror sized properly to vanity. Bathrooms 95 77 CLOSETS Remove all existing shelving, brackets, etc. Provide and install new metal covered vinyl shelves. Closets/Pantry 500 78 ELECTRICAL Install new hardwired smoke/carbon monoxide detectors. To Code 525 Convert existing outlets to GFCL To Code 150 Install arc-fault circuit interrupters for each bedroom outlet to code. Include sub-panel and separating circuits if required. Bedroom;� 250 Remove light and provide and insta114 light bath bar. Hall Bathroom 65 Furnish and install a new ceiling hugger fan with light kit, proper wiring and switch to code. Assume cost of fan and Bedrooms/Florida light kit at $95.00. Include new fan box if required. (5) Room/Li�ring Room 800 PAGE TOTAL: 4255 CUM TO'TAL: 12540 CASE #: 10-6456 5202 17`n St. DATE: 03/08/12 PAGE: #7 Rev.3/10/11 � � THE STANDARDS AND GUIDELINES SET IN BID SPECIFI(:ATIONS 2011 UNLESS OTHERWISE NOTED, ALL WORK IN THIS WRITE-UP TO FOLLOW SPEC # DESCRIPTION OF THE WORK LOCATIUN COST 78 ELECTRICAL CONTINUED Provide and install a new dry receptacle. Laundry Room 65 Re-wire area to code. Include rough out and final. Contractor to furnish any required documentation to Building Dept. Laundry Room 400 Put sign on junction box to state: JiJNCTION BOX ONLY. Laundry Room Info Only Wire new electric water heater to meet current code requirements. Laundry IZoom Info Only Remove ceiling light and track lighting. Provide and install 6 recessed lights, use existing switch and wire, to code. Kitchen 700 Provide and install a new a 4light bath bar, include proper wiring and switch to code. M. Bathroom 125 Furnish and install a new wireless door bell system. Entire Hause 70 Furnish and install new switches and receptacles. Entire House 385 Re-lamp all new and existing fixtures with standard energy efficient bulbs. Recessed lighting to receive R-30 energy efficient bulbs. Entire House 65 79 H.V.A.C. Replace existing air conditioner with a new 2 1/2 ton heat pump central heating and air conditioning system complete with all new supply and return ductwork, drops, grills, controls, control wiring and electrical including new breaker and copper to code. Minimum SEER required - 15.0, 7.5 KW heat strip. Heat pump air cooled condensing unit set on a concrete (or equal) pad. A.H. unit to be installed in attic space with access, to code. Perform proper test and balance at completion. Contractor is responsible for proper sizing of all new equipment and ductwork with the exception of the 7.5 KW heat strip. Note: New thermostat to be a programmable, Energy Star qualified product. Entire House 4800 Include eliminating existing wall return ducts and relocating/adding supply and return drops as required. New thermostat to be centrally located between new ceiling returns. Info Only Info Only PAGE TOTAL: 6610 CUM TOTAL: 19150 CASE #: 10-6456 5202 17tn St. DATE: 03/08/12 PAGE: #8 Rev.3/10/11 � THE STANDARDS AND GUIDELINES SET IN BID SPECIFICATIONS 2011 UNL'ESS OTHERWISE NOTED, ALL WORK IN THIS WRITE-UP TO FOLLOW SPEC # DESCRIPTION OF THE WORK LOCATION COST 79 H.V.A.C. CONTINUED Furnish and install a new recessed dryer vent box and exhaust duct/vent to code. Laundry Room 150 80/81 PLUMBING-GENERAL SPECIFICATIONS PLUMBING FIXTURES Furnish and install a new tub, drains, plumbing, and shower head and faucets. Hall Bathroom 650 Furnish and install new faucet, plumbing drain and shower head for the shower. Master Bath 625 Install a new elongated toilet complete with new supply line and angle stop with new escutcheon. Bathrooms 450 Provide and install new stops, traps and supplies for sinks. M. Bathroom, Kitchen. Interior 250 Provide and install a new copper water line complete with Hanson type shut-off valve for icemaker. Kitchen 250 Connect new vanity lavatory with new faucet, trap, stops, and supplies. Hall Bathroom 260 Install a new 40 gallon up right electric water heater to code. Laundry Room 650 Replace existing hot and cold supply valves for washing machine. Laundry Room 100 82 MAJOR APPLIANCES Certify all appliances are operating correctly. Allowance item. Allowance $150.00 85 PEST EXTERMINATION Inspect house for termite and/or other insect infestation. If active infestation is found, treatment will be completed by change order. Contractor to furnish a inspection report. Entire House 100 PAGE TUTAL: 3635 CUM TOTAL: 22785 NAME: CASE #10-6456 5202 17`h St. DATE:03/08/12 PAGE: #9 Rev.3/10/11 � � THE STANDARDS AND GUIDELINES SET IN BID SPECIFICATIONS 2011 UNI:ESS OTHERWISE NOTED, ALL WORK IN THIS WRITE-UP TO FOLLOW SPEC # DESCRIPTION OF THE WORK LOCATION COST 87 PAINTING- GENERAL SPECIFICATIONS Plug, patch and paint the entire interior of the building including all walls, ceilings, doors, trim, and baseboard in accordance with the requirements of this section. Stained ceilings are to be prepared properly to insure coverage of final coat. All wallpaper to be removed, walls properly prepared and painted. Interior 1200 Sand fireplace mantel down to raw wood. Fireplace Info Onlv Varnish and stain mantel after sanding to raw wood. Use clear varnish and light oak color stain. Apply(3) coats of varnish. Fireplace 250 Remove nails, brackets, hooks, screws not being used. Info Only 94 MISCELLANEOUS Remove existing window treatments. Patch and paint to match existing. Furnish and install 2" white wood faux blinds. All Bedrooms 400 Certify fireplace is properly working by licensed chimney sweep. This item is an allowance. Allowance $150.00 Have fireplace and chimney cleaned by properly licensed chimney sweep after it is certified in proper working order. Fireplace 165 Furnish and install new fireplace front. Color to be antique brass. This includes glass bi-fold doors, chain mail curtains. Fireplace 200 Provide and install new door stops on all doors. Interior 35 PAGE TOTAL: 2400 CUM TOTAL: 25185 NAME: CASE #10-6456 5202 17`h St. DATE:03/08/12 PAGE: #10 Rev.3/10/11 � THE STANDARDS AND GUIDELINES SET IN BID SPECIFICATIONS 2011 UNLESS OTHERWISE NOTED, ALL WORK IN THIS WRIT'E-UP TO FOLLOW SPEC # DESCRIPTION OF THE WORK LOCATIGN COST CLEAN-UP Clean house completely ready for re-sale. Entire House 250 PERMITS AND FEES 257 PAGE TOTAL: 507 TOTAL INTERIOR AMOUNT: 25,692.00 TOTAL EXTERIOR AMOUNT: 15,308.00 TOTAL PROJECT AMOUNT: 41,000.00 IF ANY ENGINEERING IS REQUIRED TO COMPLETE THE WORK IN THIS WRITE UP, OR TO GET A PERMIT, THE CONTRACTOR TO FURNISH IT. NAME: CASE #10-6456 5202 17th St. DATE:03/08/12 PAGE: #11 Rev.3/10/l 1 Bobbie Swetland From: Christina Petrulli [christina@scsignatureconstruction.com] Sent: Monday, May 07, 2012 9:30 AM To: Bobbie Swetland Subject: 5202 17th Street Attachments: Shingle-Timberline 30- FL10124.1.pdf; Peel n Seal - FL5259R3.pdf; IMPACT-3068- FL11321.1.pdf Here are the product approval numbers for this project: Exterior poors: FL11321.1 Shingles: FL10124.1 Peel n Seal: FL5259.3 Attached are the installation instructions if you need them as well. Thank you. Christina Petrulli Office Manager S.C. Signature Construction, Corp. 8530 Oreto Dr. Port Richey, FL 34668 727.842.5163 Office 727.992.9093 Cell 727.474.0008 Fax i EXTERIOR RESEARCH & DESIGN, LLC. Certificate ofAuthorization #9503 353 CHRISTIAN STREET UNIT #13 TRINIIY ERD OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT GAF Evaluation Report 01506.01.08-R8 1361 Alps Road, Building 7-3 FL10124-R6 Wayne, N7 07470 Date of Issuance: 01/03/2008 Revision 8: 02/06/2012 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein havp been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity�ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words '�Trinity�ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provMded to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4. Prepared by: ,�qtt[/Hpr�y-- ��,,a,t \t.•�.L. o, �;,,...;;:� � ;��Q:`�Cf 4 a,•'!y^., ��.��:Ci'�a_341"lM�•�: :i- ' ' � The facsimile seal appearing was authorized ��; _�-•,K O},r�� by Robert Nieminen,P.E.on 02/06/2012 't���.,R,^ cc•T- This dces not serve as an electronically signed Robert 7.M. Nieminen, P.E. ��'��'S��,���ti��,' tansmttedt9t�eProductqardcopieshavebeen Florida Registration No. 59166, Florida DCA ANE1983 � '�""'���"'" to the named cuent PProval ndm�nistrator and CERTIFICATION OF INDEPENDENCE: 1. Trinity�ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity�ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or disY.ributing products for which the evaluation reports are being issued. 4 Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. � TRINITY�ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. rompliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein. 2. STANDARDS: Section Prouertv Sta nda rd Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161,Class F 2006 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158,Class H 2O07 1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: Entitv Examination Reference Date GAF(PDM 1915) Letter of Equivalency SeaI-A-Ridge Impact Resistant IR O1/13/2012 PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 O1/12/2000 UL(TST 1740) TAS 107 94NK9632 03/29/2000 UL(TST 1740) ASTM D3462 O1NK06632 02/02/2001 UL(TST 1740) ASTM D3161,TAS 107 O1NK9226 05/21/2001 UL(TST 1740) ASTM D3161 O1NK37122 12/18/2001 UL(TST 1740) ASTM D3462 O1NK37122 12/19/2001 UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002 UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002 UL(TST 1740) ASTM D3161 03CA5367 03/il/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL(TST 1740) ASTM D3462 04NK13850 06/07/2004 UL(TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL(TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST 1740) ASTM D3462 05NK27924 02/10/2006 UL(TST 1740) ASTM D3161 05NK27924 02/11/2006 UL(TST 1740) ASTM D3161, D3462 06CA18077 06/05/2006 UL(TST 1740) ASTM D3161, D3462 06CA18074 06/16/2006 UL(TST 1740) ASTM D3161, D3462 06CA35251 10/18/2006 UL(TST 1740) ASTM D3462 06CA31603 12/O1/2006 UL(TST 1740) ASTM D3161, D3462 06CA41095 12/27/2006 UL(TST 1740) ASTM D3161 07NK05228 03/13/2007 UL(TST 1740) ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL(TST 1740) ASTM D3161, D3462 07CA31742 11/08/2007 UL(TST 1740) ASTM D3161, D7158, D3462 08CA06100 03/13/2008 UL(TST 1740) ASTM D3161, D3462 07CA55908 04/O1/2008 UL(TST 1740) ASTM D3161, D3462 09CA10592 03/26/2009 UL(TST 1740) ASTM D3161, D3462 09CA06856 05/15/2009 UL(TST 1740) ASTM D3161, D7158, D3462 09NK06647 OS/O1/2009 UL(TST 1740) ASTM D3161, D7158, D3462 09CA27281 08/27/2009 UL(TST 1740) ASTM D3161, D7158, D3462 lOCA35554 03/05/2010 UL(TST 1740) ASTM D3161, D7158, D3462 lOCA13686 05/15/2010 UL(TST 1740) ASTM D3462 10CA07264 05/27/2010 UL(TST 1740) ASTM D3462 10CA11953 10/29/2010 UL(TST 1740) ASTM D3161, D7158, D3462 lONK11951 10/30/2010 UL(TST 1740) ASTM D3161, D7158, D3462 lONK12070 il/04/2010 UL(TST 1740) ASTM D3161, D7158, D3462 08CA06100 01/30/2010 UL(TST 1740) ASTM D3161, D7158, D3462 10CA53934 03/31/2011 UL(TST 1740) ASTM D3161, D7158, D3462 11CA48924 10/22/2011 Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R8 Certiffcate ofAuthoNzatlon�9503 FL10124-R6 Revision 8: 02/06/2012 Page 2 of 4 � TRINITY�ERD UL(TST 1740) ASTM D3161, D7158, D3462 11CA47919 12/03/2011 UL(TST 1740) ASTM D3161, D7158, D3462 11CA48408 12/08/2011 UL(TST 1740) ASTM D3161, D7158, D3462 11CA48725 12/09/2011 UL(QUA 1743) Quality Control Inspection Report, File No. R21 05/17/2011 UL(QUA 1743) Quality Control R3915 Current 4. PRODUCT DESCRIPTION: 4.1 Marquis WeatherMax, Royal Sovereign and Sentinel are a fiberglass reinforced, 3-tab asphalt roof shingles. 4.2 Camelot, Camelot II / Camelot 30, Capstone, Country Mansion, Country Mansion II, Grand Canyon, Grand Sequoia, Grand Slate, Grend Slate II, Monaco, Timberline American Harvest, Timberline ArmorShield II, Timberline Natural Shadow, Timberline Natural Shadow Arctic White, Timberline HD / Timberline Prestique 30, Timberline Prestique 40 / Timberline Cool Series, Timberline Ultra HD /Timberline Prestique Lifetime, Timberline Majestic/TAmberline Majestic 30 and Woodland are fiberglass reinforced, laminated asphalt roof shingles. 4.3 Slateline is a fiberglass reinforced, 5-tab asphalt roof shingle. 4.4 SeaI-A-Ridge, SeaI-A-Ridge Armorshield, SeaI-A-Ridge Impact Resistant IR,, Ridglass 8, Ridglass 10, Ridglass 12 and Timbertex Hip and Ridge are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.5 ProStart Starter Strip Shingles and WeatherBlocker Starter Strip Shingles are a starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: 5.3.1 All GAF shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasa = 150 mph (V,,,t = 194 mph,l. Refer to Section 6 for installation requirements to meet this wind rating. 5.3.2 All GAF hip & ridge shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to Va� = 150 mph (V„it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Starter Shingles: Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R8 Certfflcate of Authorizatlon�9503 FL10124-R6 Revision 8: 02/06/2012 Page 3 of 4 � "i'.��'��ERD 6.2.1 Installation of ProStart Starter Strip Shingles and WeatherBlocker Starter• Strip Shingles shall comply with the manufacturer's current published instructions. 6.3 Asphalt Shingles: 6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Camelot, Camelot II / Camelot 30, Grand Slate II, Country Mansion II, Monaco and Woodland require minimum five (5) fasteners per shingle 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.4 Hip & Ridge Shingles: 6.4.1 Installation of Ridglass 8, Ridglass 10 and Ridglass 12 asphalt shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails per side [total of four (4) nails per shingle] and asphalt roofing cement. 6.4.2 Installation of SeaI-A-Ridge, SeaI-A-Ridge Armorshield and SeaI-A-Ridge Impact Resistant IR asphalt shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails per shingle. 6.4.3 Installation of Timbertex Hip and Ridge asphalt shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails per shingle and beads of Sonneborn NPl Gun Grade Polyurethane Sealant, Henkel PL Roofing and Flashing Sealant or TopCoat FlexSeal Adhesive. 6.4.4 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products couered by Florida Rule 9N-3 QA requirements. lO. QUALITY ASSURANCE ENTITY: Underwriters Laboratories — QUA1743; (847) 664-3281 - END OF EVALUATION REPORT- Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R8 Certiticate olAuthorization#9503 FL10124-R6 Revision 8: 02/06/2012 Page 4 of 4 � •nw�aan�i�n�woa o ��e'rn'tl GaOe(p lOKY'ql 3'd'NMWWS'i�PK'1 $�Ol'� •�3�.�� � �./ftY6'nM�/10 pwYP+h N�1�0 �N�MjY/�� � J N � NfM 1 at t t � vi � .�a p�ww w o�a�u � N z � "' � u�rsoas�a��w«w �/� �� ^� aam v�a�n ocz�a•o•e Q, 3a1nMQMYN S�?aQllAB �s � � ��4' � •��sunixra�oo �1�M100Ud b a O O a ^ � 0 Q' � � o � � �. � o o� ''�� + + �� k ry � � � a o o ��#�4 � �,�.a � � � ° x x J.� �;#;` � � �:#2'�;�.c'. 'Jt�AMSlf10-1H�JBH3WY7l�11V�0'XVW.DS'06 `:�,`;^�:�`.� � t� ib'>`� ,�;.F Z � ��Y � � �JMMSNI-1FI�J�3WV8d11'RI3A0'XVW110'L8 ;°e,;�,;� _ r:;?:SE�• Q ;a; � � �� � � �°- ��� � o � � ��'� � o � �� � �W � � L y Z � � '� ��� .� � Q�!r W y 3 �� � ��.� � � � i � `� � � � � � g � � '� C �o � �} �� � 8 ��$ � �� m �' � �� � � Q e� � � � �' � � ,� l0 M W \d. ��' a �'� o� �' � � a4 m z � ,�� �. �g� � �� � � � �� � Wa 4' �' t � �� � � , �� � �n a �r � 76 � M �Q W y E� �� �� a x W �� � Z � � o� .� � � � � ,, c� ' � g� �•- m � ��.� Q . �� ��� . � �� � � � � � � .� � � � � � o � � � ���� � � �� ������ g � �� ���� �� � . � �� � �1.� � •-•N P'1 f vf V h � �� �� �� �� �� �� � -- a M a h c"iZET l-'td'�+P'OI'•T'iZ£II-2illLf lt-li�s�M�eXI�BMI!'01f24i id\OOST-IObT(D�d�s+2pp�Da(Nd�s�a(ad-V�.y ' , �oN�aiw�i�n�Ni�p aww��ne 'n'tl aOOS Cy lMCY'oN 9'd'IPI�WS '!�0�`1 '��'Z'Z c�oe�ow��w aoaw+•o SVVI.3a l3NVd M000 ot at �L 1 t � ��f�' N �a i•�r»�a p aow ew+a� � N i n b L6t6'OOi'[lf s'eN��W �^ � GeCCC'L oMNPA OCZ�i 'O'A '3/� LOOQ � � � E ���.1 � 'JN'QlM�iY1iNOD Q) �VMO�JYH $�O� +Qi P�+d�O �l�J(1�(kld OC � g Z � �� H � � � � � �� � �� lV N � � ����� � ��-��-�� � �' �i���`�1 a � � � � � � � � � y �.aS l� � � .OZ't � & � �� � � � • �.. �� �� �1 � � � � �. _I � � �_� � � �� �� �� � � --I �� -�-- � �' � � � � � �t P � ���- _-- � `�0 � ��� N x o � � � 0 L� � N 1H`JBH'BNVdb000'XYW.SL'6L — rz'Q++c�oi•-t•[zs�i-tiUZ[[[-tfl���enin•aiEZ6t�roo5riorT(�s+�,p�v�laelwoW�e-at:a ' ' �oM�rinva�n.wop ow�aron0�M•a 600s;} 'qi Td 901 5��.�.JL�'�'� fi ���•Z �•���%!'�y $��� ��� rl�Z�� m � ^ � CtYS'uN uoaeqwW�v Jfl a�Yi++�o : �d l Zl 9Z t l Q �N�', � M � .+»�+a wua...�d u v�e ePw1� r� � � L61!'lG9Ytf�'aN�W � Z * ^ 90YCC'7/�YPA O[L�B 'O'� 1/� �� � fi �p � '�l11'StMI11fW1OJ �p �Y��� � � � ��� � P�r�7wwroo0 i1:�flU0}!d �� 4� •�� a � • J ' a ` \J e • � ° a ` < < a � �� I m � � � _�.._._...___,_. __ � � � • � i ��`/ �� ► > ° � � W � � � e� � P - u� o�� i3 `�g ��� ��, s ^ �� C^j N M V 1 h N � o � x � � ^ g �� � eS .z � M �I �� A`M!� f �� � � � ❑ � � � f X ❑ � � � � � � L� h g o� Z N � b+Y ar l�l O�C ^ � 1 P � J.__ u � � ��� a � � m ��� � ^� • • • � e � a o ° � a. � � . a . '-------v—�-`- n . j? W �C �� i'£'�P'OI'-i'tL£[T•Zi11ZfIT-'I��V�XI�BMU'CAEL;I dd1005i-TOrI��dWx01u,�ya(nMs77a(PW-V�:M 0.:�A-Drpjed5\Ptoje[.t FoWgts\p/oj 1401-I500\PF 14231D.RWBC DrawYgs�Fl•11321tiR-11321.1-�30.dvp,4.1 T � p � � a . e � $ A A a . 0 , � � � , � aw , ° ° Q �� � n ' ��� . � � > �� � 'a �n � a � � �� � • �•d . �� � V ' • i { � � <• � a ' . p ' Z �i � � ' . . � O.IS � i , o . ,, csx�c '' v � ° t�1 i-�ftr,�. t-U4'MIN. EMB.{IYP.)— Hv�6.(trr.J 1-t/S'MIN. EMB.In'P.) 4 T � • � 6 � � � � V a � N �° O I� � � �� � a + v �� •a � ' K r . �� d' n ° o � � . . � �^ , : . � z � � � b . I a. V ° T y •n. � � p h i-»r r,wr.� Eiv48.(TYP.) PROOl1CF. t� r� � � � � BUII.DERS FIIiRaNU1RE �p tz►�sulTAa�s,wC. I., FlB�q.ASS DWR JI. v.o.eo.sw w►ieo r�sseoa I' � � Z + Man�No.:�tACOYAtY7 Nawe Yeaa a nMwYaiw� I� y � ft in � t f YB 12 1 P�VERRCAL CROSS SECTlONS °ir"flO°�� "w�o.ecaeten no.�� �.�.���.2.� O znoe a.w.ao�,.m..e co,+.��r.r...�.,c. R:�A-Wo}Bttt\Pro]eU FoN7ers�proj 1401-1500\PF 1423\D.RWBCOr�vhgSW.-t1321�R-11321.1-.IO.dvp„5.1 W N � � � �� �� ��° � �� o �. . �. ���.� � �� � � oa � �� • ,� ; � �����.��'� �. � : ; � � �, � � ���� � . � ..��� �Q� � ���T' �pf���@., r �'�O �S���f� � � �� �'o � � �'�� �"�' � . . � ���'� �3 �. �a�� � � ,, �:�: $ , N �� �� � -� : � � �� � � � �� � __..� ,��. � �� � a �� � � ��. � ��. � �� � o � ��. Z� �: at °3 '� ���� � �—31.25' 31.25 9' �� �� � ��� � � � � � �. ��' g � =z� �'�° � �� _ � � �� n m � � � �� � � � . � ��� . � � � � —� '� � 14 MAX � � 6' �� O � p ON CBJTER � � 3 x �w � � 1" �IA a � � —11 ° S50"—�+ ��0.13'—� � Ni � � � � � � �°�`. . � '�� $ `� m Fl��C1A� D�oOR JL •.o..�a�w "`,ra:w��aaaoa � Z ni vnen.ea.:e�aesa.na� � y y '�' PART OR ASSEMBLY: nwww eoora or olor..rab aqw..■ � � �, g � , f� ,o � etxxycc�wn r�.uvcHOan� 2x �L'rL� �.�,� etxxc �r coNSrRUCrwN z.z_, i,yrqon F.9aArtidt,P.E.No.� {)zone/a.w eu��on.o cn��u�rwwra iae. �A-Projects\ProjectFolders\fxoj}401-1500\PF1423�D RWBCDrawings\FL-11321\PL-113211-t0.dwg o, a �; g�� �` o � � � �� � �� �� � a �� o a�� �� y ������ -�� 31.25 31.25" 9" W 1 ` �. � � � .iT � a 3 � °�.�;�������� g � ��_���� � � � � � � ��� �� � � � � � � � g����� �t�:: ���'g � �� �' Q X N N � � �� � � p� �70 � � j'����� '��� � � m � ��'. tdp � 0 � . . � ���� � . . ��: ��$� � � � � �� �� �a ��. � x �� �� C N mm ¢ � � � ������ � � -�,. �y� . . � � �� � �. �� �� � a ���--� � � �� � � �B ° 5.�.� ,..—�.��_____.� � � � � � � � � � ° _ ° g � � � � vaooucr: �«w►•w�•a sr• � �� 3 � �o ��ASSS�OOOR� ,/�, n.����� � � Z N I� N � �' 'aii # } t fY 1 LFS PART OR 11SSEIIBIY: c.rw�os�•a,�,d•i.W,n��onymuee Ne.s�s+� v �' � MASONRY CO�SiRl1Ci�ON �T''t" 2'=""�z Lynden R Sdmddt,P.G Ne.f.�OY ,�.3009 R.W.Bu1tolMO ConaulTwMTS INC. •\A-Projects\Project Folders\proj 1401-1500\PP 1423\D.RWBC Drawings\FL-11321\FL-11321 1-l0.dwg � + .�i�t'i,��.rn�'i�$�'i��' �v��o�ovo.;e-�x41�+ m �nao>� ara�� �, sas�so����� sa� ���N�,_ �, --�x -� -+� -� � ox o3+c—+o -' �i+s� � _��Z S�T�O SS< X N)C X X�'X � X � " a L m�� W �mm N Y 7 x N N i�A���P���A����m���7p `���wr� �� A���� ro is �y �� �� �'' �� r�-�r � ' � � �����3` �� �v�ioo Z N sp�n o�n7��Q `"'�' �Q Qy(�X'�A�.�n `�QS� An�'�i+ 7p Q ���6 V y�J�n�0 `�; Q RI a � ,�� �� �°�� � �? � � � ��O� � ������ �� � � � ���$ �� � �� � � �_ � �� � � �� � A�� � � a � � �� � � �� � �� � � � � 3Z 3� � n � ������ ' �� ' ��� � ������ � � ' � � �'���� �� �� r� ��� m(� t7 h �$ r'7, .- � g . � �,' � � � i � -�'I 1.25' 1.45' �1.?S' � N � � a � � �"._"�'f' �.�` t�O.�S � � � y PRODIlGT: Oocunwn0��nparW yi P BUILDER$F�N�WARE COt�9Al1.TANB.NC. � � � � �D F"�� �R � P.O.Bm�170 Vahbs FL S]6YD � Z N PMiw Ma:81J.lOYAtY7 � N '• � IZ' y # 1 1 2E /2 1 PART OR A�Y: c.ruNOO�.a�uuoeimtlan No.�set�� � : So BQI. OF WTERIAL.S � COMPONENfS �'�_�-•a. y�wbn F SdrNYt,P.E Ne.�JIOY 8 ZOOB q.W BYILDiNO CON�ULTANT�INO.