HomeMy WebLinkAbout12-13163 CITY OF ZEPHYRHILLS
�
. . 5335-8TH STREET
(si3)�so-oo20 13163
BUILDING PERMIT
Permit Number: 13163 Address: 5906 GREENBERRY CT
Permit Type: MECHANICAL ZEPHYRHILLS, FL.
Class of Work: A/C CHANGEOUT Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: WEDGEWOOD MANOR
Est. Value: Parcel Number: 10-26-21-0120-00000-0540
Improv. Cost: 5,579.00
Date Issued: 6/12/2012 Name: PENDLETON, FRANCIS JR & LORRAINE
Total Fees: 65.00 Address: 5906 GREENBERRY CT
Amount Paid: 65.00 ZEPHYRHILLS, FL 33542
Date Paid: 6/12/2012 Phone: 813-779-2083
Work Desc: A/C CHANGE OUT 2 1/2 TON HEAT PUMP
A 5.
�
L
DUCTSINSULATED
FINAL '�.-�Z
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80(2)(c)when extra inspection
trips are necessary due to any one of the following reasons: a)wrong address b)condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d)work not ready for
inspection when called e) permit not posted on job site f) plans not at job site g)work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of wmmencement."
Complete Plans, Specifications Must Accompany Application.All work shall be pertormed in accordance with
Ci Codes and Ordinances. NO OCCUPANCY BEFO C.O.
, .-
, i" � -�'
� NTRACTOR GNATURE PERMIT OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-813-780.0021
Building Department
Date Received phone ConWctfor Pertnittin
-r-rrrrr- --
i --�
Ownet's Name Owner Phone Number U
Owners Address��_ � Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS �� Y LOT# �
SUBDIVISION PARCELID# JO � -ql •QLZO �C.�L�O ` O�'J�L'V
(OBTAINED FROM PROPERTV TAX NOTICE)
WORK PROPOSED e NEW CONSTR B ADDIALT � SIGN Q Q DEMOLISH
INSTALL REPAIR
PROPOSED USE Q SFR Q COMM Q OTHER '--
TYPE OFCONSTRUCiION Q BLOCK Q FRAME Q STEEL Q
DESCRIP710N OF WORK � C O � �� l f S S
BUILDING SIZE SQ FOOTAGE� HEIGHT �
QBUILDING $ VALUATION OF TOTAL CONSTRUCTION
QELECTRICAL $ AMP SERVICE Q PROGRESS ENERGY Q W.R.E.C.
QPLUMBING $ ^
�"j 3l� �
�MECHANICAL $ ;!� VALUATION OF MECHANICALINSTALLATION
�
�GAS Q ROOFiNG Q SPECIALTY Q OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA QYES NO
BUILDER COMPANY
SIGNATURE REGISTERED Y! N FEE CURREA Y/N
Address License#
ELECTRICIAN COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address License# �
PLUMBER COMPANY �-
SIGNATURE GISTERED Y I N FEE CURREN Y/N
Address ' License#
MECHANICAL ' COMPANY V 'S }� � �' '�e ' �
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N •
Address l 3 License# �� �
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREA Y/N
Address License#
1111111111111111111111111111111111111111111111111111111111111111111
RESIDENTiAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Fortns;R-O-W Permit for new consWCtion,
Minimum ten(10)worlcing days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed.
Sanitary Fadlities 8 1 dumpster;Site Work Pertnit for subdivisions/large projecls
COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,ConsWCtion Plans,Stormwater Plans w!Silt Fence installed,
Sanitary Facilities&1 dumpster Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
""PROPERTY SURVEY required for all NEW construction.
Directions.•
Fill out application completely
Owner&Contractor sign back of application,notarized
If over S2500,a Notice of Commencement is required. (A!C upgrades over 57500�
" Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter fmm owner authorizing same
OVER THE COUNTER PERMITTING (Front of Application Only)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter'rf on public roadways..needs ROW
NOTICE OF DEED'RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
appflcable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as requlred by law, both the owner and contractor may be cited for a misdemeanor violation
under state law If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work,they are advised to contact the Pasco County Building Inspectfon Division—Licensing Sectfon at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the"contractor Block"of this application for which they will be responsibie. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entiHed to permitting privileges in Pasco
County.
TRANSPORTATION IMPACTlUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands,that such fees,as may be due,wili be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prfor to
receiving a°certificate of occupancy"or final power release. if the project dces not involve a certificate of occupancy or
final power release,the fees must be paid prfor to permit issuance. Furthermore, ff Pasco County WaterlSewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I
certify ihat I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the'owner°, I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the'owner"prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all taws regulating
construction, County and City codes, zoning regulations, and land development regulaUons in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be fn comptiance. Such agencies include but are not limited to:
- Depariment of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,WatedWastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalis,Docks,Navigable Watervvays.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Welis, Wastewater Treatment,
Septic Tanks.
- US Environmentai Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V"unless expressly permitted.
- If the flll materfal is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume"will be submitted at time of permiHing which is prepared by a professional engineer
licensed by the State of Florida.
- If the fili material is to be used in Flood Zone 'A" in connection with a permitted building using stem wall
construction,I certify that fill wili be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such flll will not adversely affect adjacent
properties. If use of fill is found to adversely affect adJacent properties,the owner may be cited for violating
lhe conditions of the building permit issued under the atlached permit application, for lots less than one(1)
acre which are elevated by fiil,an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this a�davit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to vfolate,cancel,alter,or
set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Buildirig Official from thereafter
requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
ihe permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension
may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate
justifiable cause for ihe extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WIT Y R LE D R R TTORNEY EFORE RECORD NG Y R TIC MM NC MENT.
FLORIDA JURAT(F.S.117A
% '
OWNER OR AGEN�` CONTRACTOR
Subscrlbed and swom o ed e s Subscribed a� or a rtned) e me this
by � ' by/7'1 iC h�'1� �S
Who islare personally known lo me or has/have produced Who is/are personally known to me or asR�ave produced
asidentlficatlon. asidendRcadon.
NoNary Publlc Notary Public
Commission No. Commission No.
Name of Notary typed,printed or stamped Name of Notary lyped,printed or stamped
Pasco County Parcel: 10-26-21-0120-00000-0540 001 Page 1 of 1
Data Current as Of: � Weekly Archive - Monday, June 11, 2012
Parcel ID 10-26-21-0120-00000-0540 (Card: 001 of 001)
Classification� 01 - Single Family
Mailing Address Property Value
PENDLETON FRANCIS L JR& Ag Land $0
LORRAINE D LIVING TRUST Land $21,079
PENDLETON F L)R&L D TTEES Building $68,094
5906 GREENBERRY CT Extra Features
ZEPHYRHILLS FL 33542-7963 $�86
Physical Address )ust value $89,959
5906 GREENBERRY C'f Assessed (Save Our Homes) $89,959
ZEPHYRHILLS FL 33542
Homestead 196.031 - $25,000
Leclal Descriution (First 4 Lines) Non-School Additional Homestead Exemption - $25,000
See Plat for this Subdivision,�" Non-School Taxable Value �39,959
WEDGEWOOD MANOR PHASE I &II School District Taxable Value �64,959
PB 27 PG 11-14
LOT 54&WEST 2.0 Ff LOT 47 Warning: A significant taxable value increase may occur when sold.
Click here for details and info. regarding the posting of exemptions.
OR 6427 PG 1597
Land Detail (Card: 001 of 001)
Line Use Description Zoning Units Type Price Condition Value
�1 0100 SFR OOR4 4,500.00 SF $4.65 1.00 $20,925
�2 0100 SFR OOR4 532.00 �F $0.29 1.00 $154
Additional Land information
Acres 0.12 Tax Area 30ZH FEMA Code �Residential Code WDGWLPl
B�ildina Information - Use O1 - Single Family Residential (Card: 001 of 001)
Year Built 2001 Stories 1.0
Exterior Wall i Above Average Exterior Walt 2 None
Roof Structure Gable or Hip Roof Cover Asphalt or Composition Shingle
Interior Wall i Drywall Interior Wall 2 None
Flooring i Carpet Flooring 2 None
Fuel Electric Heat Forced Air- Ducted
A/C Central Baths 2.0
r- Line Description Sq. Feet Repl. Cost New
1 BAS 1,288 $69,423
2 FOP 20 $270
�-3 �-FGR 441 $9,486
Extra Features (Card: 001 of 001)
Line Description Year Units Value
1 DWC 2001 327 $601
� 2-�� CON PTO 2008 88 $185
Sales History
Previous Owner PENDLETON FRANCIS L&
Year Month � Book/Page Type Amount �
2007 04 7455/ 0143 WD � $0 �
2005 06 -1 6427 / 1597 � � �0
2005 04 6318/0715 WD $110,000
http://appraiser.pascogov.com/search/parcel.aspx?sec=10&twn=26&rng=21&sbb=0120&b... 6/12/2012
t22 `��4TOA '(.:ube4�j si�kg � � �-�
ro ress Ener Y s No� � �`� .' ��� r
� � �, �, � � { �r��
. r ��U � �_ .irista��a: - ro�ducti ��
� on Re ort
� ��x
uscomer: ��/9�,�C L � �/? �� ..''`_ �''`�,c�
� Sale Pnce: �� �
.ddress: c-�1�� � � , .. „•, —`
�
�j"Y Down payment:
itY�_ � � � Zip "���j Balance Due:
ubdiviszon:�, ��-� ,, .�� �.��- . �Met�iod:�) �
hone:_ .,_�/�������L�'3 Credit Card #
old by: , � =' TM# � --
CC Exp Date
istall Dat�e: ann/pm ���r:o�al#
ell #: Seaso�a�: Next Visit Date
�uipment Type ; � n
� � �� _,. SEEk
10A� C , com warr
�iSting'A/H�Mak.e: ', S C 0 com w rr
�_Size: Year:
tisting Cond Make: '�O�,�Z Size: ' ' Yea3-:__ �j /
�ckage Unit Make: Size: ' Year:
[odel # �}F� r p C)(�� � $�i-��:�#
[Odel #_ '�C' f-ft���� — L 04 �/�(� ��1�'}
�-( I Seri�.al # L a I v `'� ���„�-1'r�
,xistin.� Ch�ecklist Items ❑eeded
�T ; or �V�ct tt��arage�Claset �'-stat: � T e: c' - (�.
:lc,�et Size. V�ri r} H m YP �� ' � ..�-
�---- Emer. Drai p a n t.��'l o a t S w i t c h �.--
cuttle/Cubby��Op�r�n�g: W L H�ea# shie�ld ✓' K.W. �" -----
'ront Draw or Bottom Draw Lig�it kit �. C'_S• Hang kit �--�
:reaker size AI�-i � Co.n� �kg pad ✓� $reaker
reaker Brand �Cl,.j��n ���� D Box � �
jire Type % �j (circle) a��o� Alum. P"�C t�``. �'lp --
uet CO ar astic Suppiies Retu�n Filter Rack A�O ✓
ond:�OUn�d�Roof Thru-Wall Sn' platform
t�nit needs Lifted Anchors c_--qp�#
�LJ Zones L--- Ra�in�shield ,
asco Only: Mobile Homes l�ieed �lectri���ati.
ear Make g�ye �� � �_Crane
� ����� �p�
15�-���� � w��te���v,��-S,pQi�c � �.� �m p —
Re-Install: UV I3�'VV R��' L/A Gnrr�osion Grenade Hardsta N/A=�
) . �.
,) �
nsta]ler: �- . ``,,a Permi: ee� or No #
. —_
'r �ssed By: ' Parc.el I.D. #:
(�LJpdated �arranties �Increased. Efficiencies
���s
� , �
�
:�utliorization Letter
I, Jeff Allowa��, license u ber CA 056S71,Nerebt auth rize the following to act as m� ag�nt in
obtaining permits in � � ��
0�1 t � .1�� 1. � r P� ��-`gt� -g a �y o_.�
�gents Name Dri�er I.icense �umber °
Agents ?�ame I�ri�er L,icense `'umher ~
� ��gents I�ame Dri�er License '�'umber �^
-�gents Name Dri�er L.icense Vurnber �
:�gents Name Dri�er License �urnber �
:�ge�rts Name nri��er I.icense '�umber
This authoriz n is to re n in� inde��ely-. unless canceled h�• me in
.r ri�ixrg:""."._.
�uthorized Age ignaCure + -
`+KO� to and�ubs�ik� to before me this l Z da�� of , :20� _
R� �Q.�_��_(�, w•ho is p • now ta me or $
— _____ __ _as identi�catian who di (did no ke an oa .
otarv u � ,
��
My� corr� w y• r{'py��� /
�a; ��q�(�,tj�� y�� �-
L..ti. ��ir Conditioning, Heating & Refrigerarian =���_ � 9p�'�`�='��= ^
�c• o � wo•ps
5827 13t� Avenue =�;�� °� • Nm;�=
:c�Q°S- a , ��a��s
�e�ti Port Riche;��, FL, 34652 �%�;aP2 �, �,�a;,��,`
727-846-8818 1-800-840-8818 .9.*••:���� .• �.
Far: "727-842-8$SO s���i�'�FIORIDA •* �����!\
��hltI1111111�����\
.
O
� ��
Duct Seal Affidavit
Company� �, � e � 1� License# ( ,�( .�5�/ /
Address.S /��P �Y�2�'l�rfLi � Permit# � 3���
� affiant,hereby affirm that I am the duly licensed contractor of record for the above
e nced permit,that all of the forgoing information is true and accurate,and that the duct sealing at the above
referenced address has been completed in accordance with all applicable codes and standards.
Contractors Name(printed)I , `�-r�s� � '�'.Z I��� � Date�(�'����
Signature
�...
� � � Des i r� Star �aa� �alcu lati � n
,
` : � Result�are intended for use with Rheern heat'
� mg and coohng systerns only
I'',r:Palt ,�tt"r,t'
� � f • • , i •
Location:
Street Address 5906 GREENBERRY CT, PASCO, FL 33542
Latitude, Lonc,t� if 27.9961°, -82.582°
House Square Foot��cae: 1285 sq.ft
Name: =- <iNCIS PENDLETON
Phme: 8'3-779-2Q83
Emaii: =� �mple@mail.com
� � ��`' � � • . . . � .
Outdoor Heating Cooling
Dry bulb (°F� 40 91
Daily range M
Relative humidit� 50%
Masture differer;c= 56
Indoor Heating Cooling
Indoortemperature�, F) 70 75
Design temp�ra�.,re :iifference(°F) 30 16
Area Btuh % ofload
' Wall� 2165 11.9
F`� ' 4866 26.7
Ceiling 2048 11.2
Windavs 2760 15.1
Infilhation 4743 26
System Efficiency Loss 1658 9.1
Total: 18240
H eati ng Loads
�s� _. , �-, ,,:
�System Efficiency Loss
i
Floor � : -
�':�r�;'�" Ceiling
.� //.
�
'__.,.._-,-W a I I
�
Infiltration � �- Windows
Area Btuh % ofload
Wa�� 1154 4
Geiling • 1092 3 7
Windanrs 15928 54.5
Sensible Infiltration 1897 6.5
Latent Infiitration 4105 14
System Efficiency Gain 2418 8.3
Intemal 1445 4.9
Sensible People Load 5g2 2
Latent People Loed 592 2
Total: 2g2z5
Sensible load 24528
Latent load 4698
SHR 0.84
Capacity at.75 SHR 2.73 Tons
Cool i ng Loads
Z:�,�?: G't_� i�r
Sensible People l.oad
--- Latent People Load
��--- Ceiling
� s �--Wall
' � Intemal
� .
� �-- Sensible Infiltratioi
Windows --`"`�� ---__
System Efficienc�
�
- Latent Infiltration
' AED Graph
3;�,c,�,o
"Lt1�;U0 ���,Y�
�
10(�00 �""""'°"°",...---...
"..-�..�
p
Qarn 9a�7� l0a�r; llarra i2pm 1pm 2prr: 3pin .1p!Yi SG�n� a��r� 7pm z�pm
— Hourly Loads —Aver�age
. .
System equipment selection will be made using the follaving Manual S denved values.
Summer Outdoor 91°F
Summer Wet Bu1b 77°F
Summer Indoor 75°F
5ummer Design Grains 50%
Winter Outdoor 40°F
�nter Indaor 70°F
Sensible Coding 24,528 Btuh
Latent Coding 4,698 Btuh
Required Coding Airflav 1,115 CFM
Sensible Heating 18,240 Btuh
Required Heaing Airflaw 237 CFM
All calculations are based upon apprwed hvac industry standards and procedures, and comply with all loca�, state and
federal code requirements.All computed results are Estimates. Product pravided by Energy Design Systems and Idea
Tree