Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
12-13282
' CITY OF ZEPHYRHILLS 5335-8TH STREET , (813)780-0020 282 FIRE ALARM SYSTEM PERMIT � Permit Number: 13282 Address: 38112 15TH AVE Permit Type: FIRE ALARM SYSTEM ZEPHYRHILLS, FL. Ciass of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: COMMERCIAL Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 11-26-21-0010-01200-0250 Improv. Cost: 2,500.00 Date Issued: 7/30/2012 Narr�e: NYE, McALVANAH & HENSON Total Fees: 200.00 Address: 38112 15TH AVE Amount Paid: 200.00 ZEPHYRHILLS, FL. 33542 Date Paid: 7/30/2012 Phone: Work Desc: INSTALLATION FIRE ALARM BRIGHT BEGINNINGS DAYCARE FIRE INSPECTION FEES 50.00 � 3�� � � � � � � � � � �� na FIRE ELEVATOR RECALL Chapter 633, Florida Statutes,authorizes the City to charge and aollect user fees to pay for the aosts of fire prevention and protecNon related activitles such as inspections,plan review,administrative fees,and other aosts related bo the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Depardnent's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in acoordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO BTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN O BEFORE RECORDING YOUR NOTICE OF COMM � CONT CTOR SIGNATURE PERMIT OFFICER PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION -8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041 813-780-0020 Ciry of Zephyrhills Fire Fax-81 -780-0021 ; � Permit Application / ,n (�u�— ate Received � ��� � �� Phone Contact for Permit V ��' �Q� r— ��.J C" '� � s— , voner's Name ✓ i ��� Owner's Phone Number tivner's Address y� (� - C(jL{f,l�C Uj� 2 �� � 3l�Q S` ee Simple Titleholder Name -"'� Titleholder Phone Number C� � � ee Simple Titleholder Address -�-^' -,,.,.. n,�:.�_,. .. . �,--•. >_.,� - _.•.,��.,�, � ,.; ,.xx ,.. ..,�, .�,. � — --__ .. . _ _ �r , : .. _+;.,:�.�._a:. . -a.�.�s°. . .-_. ... �b Address �a � /�'�� G.P�lT � G�5 rv � 3 G'� Lot# � ub Division Parcel# " - , : _ , -�...w,r �,.�,._.�,. �,�,. .;�,�-,s�.,_ s -.� � 4, _ , m e. � _.- ,-w:,,�a:�-�z.�t-�€s.�sn.rr �ss�-t.as^t..A�r r� w;K„� _ _, . ,, - � Bio-Hazard Waste Storage-ANNUAL � FumigaUon Tent � Comm Exhaust Kitchen Hood/Duct � Hazardous Material(Tier II or RQ Facility)ANNUAL � Controlled Bum � Hood Installation � Emergency Generator<30 kw � LP/Natural Gas-installation � Emergency Generator>30 kw a LP/Natural Gas-ANNUAL Sale � Fire Protection Maintenance-ANNUAL � Places of Assembly-ANNUAL �y emi �n er Sprinkler � ❑ � ❑ B � Recreational Bum �- Fire Alarm O ❑ ❑ � � Sparklers �� / � Hood Cleaning ❑ � ❑ � � Sprinkler System Installations �� Hood Suppre�sion � ❑ ❑ ❑ � � Standpipes(Sprinkler Sys) Fire Alarm Installation J � Torch Roofing/Tar Kettle �,___,--��.___ Fire Pumps � Waste Tire Storage ANNUAL � Fire Works � Flammabie Application-ANNUAL � Valuation of Project Fuel Tanks ,� Q Other: - - - ... _ �. _ .� �. — ... ���.. , . _ _. � , _ • � ;.}z-»_ ��, .�� . � � . .. , . ��, . ,-�.� ontractor Company �- �, , ignature � Registered Y N Fee Current Y/N Address License# LECTRICIAN Company ignature Registered Y/N Fee Current Y/N Address License# LUMBER Company ignature Registered Y/N Fee Current Y/N Address License# �— IECHANICAL Company ignature Registered Y/N Fee Current Y/N Address License# THER Company ignature Registered Y/N Fee Current Y/N Address License# irections: Fill out application completely Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement is required(Mechanical work over$5000) Supply two(2)sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com) NO'�ICE OF DEED RESTRICTIONS The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be resQonsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owne�' prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: 1 certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that a�l work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If I am the AGEN7 FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, ptumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technicat codes, nor shall issuance of a permit prevent the Building O�cial from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirtned)before me this 5ubscribed and swom to(or affirtned)before me this by by Who islare personally known to me or has/have produced Who is/are personally known to me or has/have produced as idenNfication. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped ZEF��IYRHILLS FIRE DEPARTMENT � 6907 Dairy Road, Zephyrhiils, FL 33542 Fire Chief Keith Williams Bus(813)780-0041 Fax (813)780-0044 FIRE SERVICE USER FEES Occupancy No.: Pfan No.• Contractor. Business Name: �<< <�.�,:�. � i C.+,fe Bitling Address: � C� �- s -��c., ; ps :.�,�c Business Address: ,bz / �, `� L� ' u�.�-us ' ��� ;�33G�S� Business Phone No.: ah�� �S Billing Phone No.:�/3'S�:� ��8ys Business Fax�ow.: Billing Fax No.: Contact: /!l r�l �/ Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE q�pRM FEE 8 Site Plan N/C Mnual WC Spr(nlder S50 1st Alami N/C Mulli-Femlty/Commerciel .O6 sf 1st Re-inspeCNon N!C StandP�P� S50 2nd Ala►m N/C (Minimum Charge 525.00 2nd Re-inspedion 5100 Flre PumP t50 3rd Alami N/C am Plan Revislons DBL 3rd Re-(nspection 5250 Hoods s50 �th Alarm 5100 4th Re-In�pec�ion 5500 Fire Alami S50 5th Alarm St 50 SPRINKLER SYSTEMS (Bus�cbsed tm�l LP� � �A�� � 8 0-25 Hesds S50 vblat(on�oorroctedj Natt�ral Gas S50 woN co�w.uricE - 5150 26 Wus Heads 3100 SPItINIC1.ER SYSTEMS Fuel Tanks- psr tank �50 STANOPIPE SYSTEM Hydro Underprounds S45 Sparklers s100 �Per Riser S50 Hydrostatio Test S65 a�.r�•m Firo Waics �pp FIRE PUMP Accaptance Test s45 os►.yse.m Csmp Fke � �Per PumP 5100 HydraN Flow S75 CordroNed Bwn 3100 FIRE ALARM SYSTEM HoodlDuct j50 �0-25 Devices s50 FIRE ALARM SYSTEM p��A��...�,�,' •����� � Annual 26 plus Devioes � re�100 �3ystem Acceptance S50 Fire Protection S25 SUPPRESSION S MS Recaq Acceptance �Sp p�� � ��� Wef S50 OTHER Waste Ti�e Storape S50 �,,,,u.i �Y S50 Fire WaWSmolro WaN S15 psrw�q Ger�eteto�<�(y� s�pp CO2 S50 LP Gas 325 peramc Cienerator>30 KW 150 � sso �c� azs ,�,.,�, eb-�ra wa�te s�oo �., KITCHEN EXHAUST Fumipstlon Te� �,5p �HoaUOucts S50 Tent 10'x10'or yrsster S15 w►aMC Torch Pof/Applied ZSp OTHER Flre Pump S45 Haz.A�lateriels i100 �nr„w LP Inatallalian par lank s50 Fke Suppre6slon �3p Fuel Tank Installetion S5p gyst� q�� (Per Tanky S50 8 E�t Hood/p� �p �Naturol Gas MsfaNation s50 Re-in�pec;tlpn DBL (Per System) (otha�d�an annual) ❑SP�y�h S50 �Inspe�ion sched�ed DBL and cancaNed less than 8 . 24 haus co�n,aio�i�. wc Erneryency Vehicle Aa t50 FALSE ALARM PLANS TOTAL� INSI+ECf ION TOTAL� PERMIT TOTAL� - - TOTAI,C^+_) - - (3RAND TOTAL Comments: -_pa ' 2 t)!Z Insq,��tor: Zephyrhills Fire Rescue 6907 Dairy Road, Zephyrhills, FL 33542 Fire Chief Bus (813) 780-0041 Keith Williams F� (813) 780-0044 24 July 2012 Plan Number 12-026 Project: Fire Alarm system for Bright Beginings Day Care, 38112 15`�'Avenue Number of Pages: 1 Pages, plus 12 pages of documentation for alarm components This Officer has reviewed the plan for the Fire Alarm system installation of new daycare occupancy located at 38ll2 15�'Avenue, Zephyrhills. Plans are approved as submitted with the following conditions: 1. All installation shall be performed by a Florida licensed Fire Alarm Contractor to NFPA 72 Standards. An identified contractor listed is listed on the permit application. 2. Fire Alarm Control Panel room shall be labeled/placarded with signage identifying panel is within the room. Payment of permit fee indicates acceptance of the requirements of these revi.ew comments. Inspections Required: 1. Final Fire Alarm acceptance test required, this may be done at building final inspection. Review and approval of the submitted plans does not relieve the contractor from the responsibility of correcting any deficiencies noted during inspection. Respectfully submitted on 24July 2012 by, C����'v�G�c�--.� Keith A. Williams, EFO, CFO, CEMSO, MIFireE Fire Chief Fire Safety Inspector, #148104 , . July 14,2004 DF-52013•E-500 • Fi re��iTe�A�arms B�'� z� Addressable Manunl Pull Station www.firelite.com Section. Addressable Devices GENERAL Patented, U,S. Patent No, D428,351; 6,380,846 The Fire•Lite Alarms BG-12LX is a state-of-the-art, dual- U.S. Patent Pending: 09/686,286 action (i e , requires two motions to activate the station) pull station that includes an addressable interface �.� Califomia �r�� State Fire (mounted inside)for Fire•Lite's addressable MS-9200, MS- � '�-� Marshal 9200UD, and MS-9600 fire alarm control panels Because `' �` us ``'��' R ����i 7150-0075�184 the BG-12LX is addressable, the control panel can dis- �� play the exact location of the activated manual pull station ��STED This leads fire service personnel quickly to the location of M EA the alarm �M FEATU RES 67-02-E • Aesthetically pleasing, highly visible,dual-action design APPROVED • Meets ADA 5 Ib maximum pull force • Easily operated (dual-action) • Attractive shape and textured finish __ • Mounts, semi-flush, to a standard single-gang (2 125" � [5 3975 cm] minimum depth), double-gang, or 4" (10.16 cm) square electrical box. • When the handle latches in down position,the word"AC- TIVATED"appears at the top of the handle in bright yel- low to dearly indicate the station has been operated • Key/lack resei; needs oniy a 1i4-t�irn to lock/unlock • Includes Braille text on station handie ' � • Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mmz wire). • Optional trim ring (BG-TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes • Maintenance personnel can open station (for inspection and testing) without causing an alarm condition /o��, � • Built-in bicolor LED, which is visible through the handle �_ of the station,flashes red in normal operation and latches on steady red when in alarm __ --- -- 52004P�1P9 CONSTRUCTION BG-12LX Shell, door, and handle are molded of durable LEXANO (or polycarbonate equivalent) with a textured finish Manual stations connect with two wires to one of the con- trol panel SLC loops Each manual station, on command OPERATION from the control panel, sends datsa to the panel represent- Pushing in, then pulling down on the handle causes it to ��9 the state of the pull station switch Two rotary decimal latch in the downlactivated position Once latched,the word switches allow address settings (01-99). "ACTIVATED" (in bright yellow) appears at the top of the pRODUCT LINE INFORMATION handle, while a portion of the handle protrudes from the bottom of the station To reset the station, simply unlock BG-12LX Dual-action addressable pull station the station with the key and pull the door open.This action Includes key lock/reset feature resets the handle, closing the door automatically resets SB-1/0 Surface backbox, indoor/outdoor the switch LEXANO is a registered trademark of GE Plastics, SB-10 Surface backbox. a subsidiary of General Electric Company BG-TR Optional trim ring Fire•LiteRO Alarms is a Honeywell company. 1S0 �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate We cannot cover all specific applications or anticipate ail requirements All specifications are subject to change without notice For more information, contact Fire•Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. 9YCIIIEERINi 8 MANUfACiI�IIMi Phone (800) 627-3473, Toll-Free FAX. (877) 699-4105 Q U A L 1 T Y S Y S T E M S DF-52C13•07/14/04 — Page 1 of 2 INSTALLATION ARCHITECTURAL/ The BG-12LX can be semi-flush mounted into a single- ENGINEERING SPECIFICATIONS gang,double-gang,or standard 4"(10.16 cm)square elec- Manual Fire Alarm Stations shall be non-code, with a key- trical outlet box,or surface mounted to the Model SB-I/0 or SB-10 surface backbox If the BG-12LX is semi-flush operated reset lock in order that they may be tested, and mounted,then the optional trim ring (BG-TR)may be used so designed that after actual Emergency Operation, they The BG-TR is usually needed for semi-flush mounting with cannot be restored to normal except by use of a key An 4" (10 16 cm) or double-gang boxes (not with single-gang operated station shall automatically condition itseif so as boxes) to be visually detected as activated Manual stations shall be constructed of red-colored LEXANO (or polycarbonate ELECTRICAL SPECIFICATIONS equivalent) with clearly visible operating instructions pro- Normal operating voltage: 24 VDC vided on the cover The word FIRE shall appear on the front of the stations in white letters, 1 00 inches (2 54 cm) Maximum SLC loop voltage: 28 0 VDC or larger Stations shall be suitable for surface mounting Maximum SLC loop current: 230 NA. on matching backbox SB-I/0 or SB-10�;or semi-flush mount- ing on a standard single-gang, double-gang, or 4" (10 16 cm)square electrical box, and shall he installed within the limits defined by the Americans with Disabilities Act(ADA) �a" �°l'�� �� or per national/local requirements PJlanual Stations shall ;^�� ^����: ' ''�.�t `��;�� �3w. , ``;:�:�;�, � be Underwriters Laboratories listed '� ' y � �"� �r ° � �v' �"` Manual stations shall connect with tv�✓o wires to one of the . a', .�.T..w. ,,i.' �r ':��i€=�.� �;� "' �: ���"'��.„�� " control panel SLC loops.The manual station shall,on com- ,�.. , , `��"� �Y �� � `'n`° t mand from the control panel, send data to the panel repre- _.�`" �:,�.. 4 ., ���'sr.e ���.���:"��' '. ��= senting the state of the manual switch Manual stations shall ;�����'°� ` � � ��r`�;;: rovide address settin b use of rota decimal switches. �'`�`,�'»`�� �° �;�,°.` / P g y ry � w��,r`"a��� `� TERM/NAL "�� a�P*�,.~' '��: �;.. �""'� #'` " � CONNECTIONS r?�.,;S��.., ��� �� �"?�-'��::�' - 1 SLC (—) � Y�>'����y�'f�, , ,�. h ° ���" - � ! 2 SLC (+) y , � ". _> ,�m".�E;:�'�..r ,. �`::����:�.��� ���;�.,�• .:.� ,x ����� � ;o-_.�r rYk�:,�: ; t"�.aC's.',��-i� 'Led .4a2�'."�. ��5_ "�,'�,'.,'�;r�°. r,�,:.:�, ' - �.g� •� '�n .i:'�k', ,'y�, Back of station without door. o � �,�'-,F''=`- o � �" z -="� z r�'e ',a�� 3 , (� � t, 4 I ' j i 4 , ,_�F � .;�� s - ����,5 ° I-- s 9 g 7 6 9 8 6 �- c N � ����.�. ` � '� �; _ ,� _ � , �� - I; � � �� -- - - � i -; -- ��o ��r�� �� — _ �� LED �a�l����r�� - - � I �— — --' ROTARY DECIMAL SWITCHES — --_ � --�_ �����, _ -- I� �; �7 "` �' ' =;� �r — � , — I``'��ggg='�71��D ; ^ -- - I uL _- = li � 8��.�.,e..A =— I � ` Cover open fo show easy access to the addressable interface module,rotary switch, and UL label. Page 2 of 2 — DF-52013•07/14/04 • � � •� SILENT SK-5235 KNIGHT Remote Annunciator by Honeywell Program and Operate the SK-5208 FACP from a Distance with the SK-5235 Remote Annunciator. The SK-5235 remote annunciator provides remote annunciation for the SK-5208 Fire Alarm� Control Panel The SK-5235 performs all system operations. It also provides trouble and alarm information anCl can be used for programming The SK-5208 can support up to six 5235 Remote Annunciators. Call Silent Knight today for more information 1-800-328-0103 Operation When the system is normal and .- receiving AC power, the power �ED is on and all other LEDs are off. Other LEDs turn on as the conditions occur Users identify themselves to the control panel by entering a code on the annunciator When a user presses a button, the annunciator piezo beeps and the �CD prompts the user to enter a code or other � relevant information Features SK-5235 Remote Annunciator • 2-line 16-character LCD display • Indicates Trouble,Alarm, Supervisory, and System Status Specifications Ordering Information conditions with LEDs and LCD Operating Voltage 24 VDC SK5235 display Current Draw: Remote Annunc;iator • Each SK-5235 is individually Standby• 30 mA supervised by the SK-5208 Alarm. 50 mA FACP Dimensions: C0111patlbl@ PPOC�UCtS • Up to 6 per SK-5208 FACP width. 7-3/16" SK5208 (18.26 cm) • Operation and appearance Height: 5^ Fire Alarm Control Panel comparable to the control (12.7 cm ) panel's on-board annunciator Depth. 1-1/8" • Can be wired up to 1500 ft from (2.86 cm) FACP Operating Temp 32°to 120° F • OPR operator's key ships with (0°to 49° C) SK-5235, this key can be used Maximum Wiring to perform user operations, but Distance 1500ft will not open the control panel door Approvals • MEA 429-92-E • CSFM 7165-0559�137 • UL Listed • • � •� SK-5235 Remote Annunciator Engineering Specifications The contractor shall furnish and install where indicated on the plans, the Model SK-5235 Remote Annunciator. Module shall be of a LCD type with a 2X16 display. Module shall be capable of remote programming as well as providing alarm, trouble information along with resetting of alarms and silencing of trouble and alarm conditions. Module ID shall be programmed with a 4 position DIP. The control shall be capable of sup�orting up to 6 supervised SK-5235 Module shall be designed to mount on a dual gang electrical box with 18 gauge to 14 gauge wire ; � � �\ d V � �� �� � � �-' �� /� � i � i � ` i ° �- Ss � o / R 1 � � � � a � i / a°i 1 � / � / � / �, SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350321 Rev C by Honeywell subject to change without notice.For more information,contact Silent Knight O 2010 Honeywell International I�c. 12 Clintonville Road,Northford,CT 06472-1610 Phone:(800)328-0103, Fax: (203)484-7118. www.silentknight.com • � � �� SILENT SK-5235 KNIGHT Remote Annunciator by Honeywell Program and Operate the SK-5208 FACP from a Distance with the SK-5235 Remote Annunciator. The SK-5235 remote annunciator provides remote annunciation for the SK-5208 Fire Alarm Control Panel. The SK-5235 performs all system operations. It also provides trouble and alarm information ancl can be used for programming. The SK-5208 can support up to six 5235 Remote Annunciators. Call Silent Knight today for more information 1-800-328-0103. Operation When the system is normal and receiving AC power, the power LED is on and all other LEDs are off. Other LEDs turn on as the conditions occur Users identify themselves to the control panel by entering a code on the annunciator When a user presses a button, the annunciator piezo beeps and the LCD prompts the user to enter a code or other � relevant information. Features SK-5235 Remote Annunciator • 2-line 16-character LCD display • Indicates Trouble,Alarm, Supervisory, and System Status Specifications Ordering Information conditions with LEDs and LCD Operating Voltage: 24 VDC SK5235 display Current Draw� Remote Annunr,iator • Each SK-5235 is individually Standby� 30 mA supervised by the SK-5208 Alarm: 50 mA FACP Dimensions: C0171patlbl@ PPOCIIlCtS Width. 7-3/16" • Up to 6 per SK-5208 FACP SK5208 (1826 cm) • Operation and appearance Height: 5" Fire Alarm Control Panel comparable to the control (12.7 cm ) panel's on-board annunciator Depth: 1-1/8" • Can be wired up to 1500 ft from (2.86 cm) FACP Operating Temp 32°to 120° F • OPR operator's key ships with (0°to 49° C) SK-5235, this key can be used Maximum Wiring to perform user operations, but Distance: 150oft will not open the control panel door Approvals • MEA 429-92-E • CSFM 7165-0559�137 • UL Listed • � � •� SK-5235 Remote Annunciator Engineering Specifications The contractor shall furnish and install where indicated on the plans, the Model SK-5235 Remote Annunciator. Module shall be of a LCD type with a 2X16 display. Module shall be capable of remote proyramming as well as providing alarm, trouble information along with resetting of alarms and silencing of trouble and alarm conditions. Module ID shall be programmed with a 4 position DIP The control shall be capable of supporting up to 6 supervised SK-5235 Module shall be designed to mount on a dual gang electrical box with 18 gauge to 14 gauge wire ��� u U � �'� � � �-' G � � � � i ,� � � n SS � o I " r � / J N � i I N � � / � / / / l .� SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350321 Rev C by Honeywell subject to change without notice For more information,contact Silent Knight c0 2010 Honeywell International Inc. 12 Clintonville Road, Northford,CT 06472-1610 Phone.(800)328-0103, Fax:(203)484-7118. www.silentknight.com �� SYSTEM �� SENSOR� Selectable Output Horns, Strobes, and , Horn/Strobes SpecrrAlert�Advance selectable-output horns,strobes, �_�: '. and horn/strobes are rich wirh features guaranteed to cut installation times and maximize profits. SPECTI!'�''��C� Features The SpectrAlert Advance series of notiFication appliances is •Electrically compatible with existmg SpectrAlert products designed to simplify installations,with features such as plug in •Automatic selection of 12-or 24-volt operation at 15 and 15/75 designs,instant feedback messages to ensure correct installation of candela individual devices,and 11 field-selectable candela settings for wall and ceiling strobes and horn/strobes. •Plug-in design •Field selectable candela settings on wall an�ceiling units 15,1 S/75, When installing Advance products,first attach a universal mounting 30,75,95, 1 10, 115, i 35, 150, 177, 185 plate to a four-inch square,four-inch octagon or double-gang •Same mounnng plate for wali-and c2�linq-mount units junction box.The two-wire mounting plate attaches to a single-gang •Shorting spnn�cn mounUng plate foi conUnuity check before lunction box. instailation Next,connect the notificat�on appliance circu�t wiring to the SEMS •Tamper resistant c�nstruction terminals on the mounting plate. •Outdoor wall and ceiling products rated from-40°F to 1 S 1°F •Design allows mmimal intrusion into the bac� box Finally,attach the horn,strobe or hom/strobe to the mountirg plate •Hom rated at 8�+dbA at 16 volts by inserting the product's tabs in the mounting plate's grooves.The device will rotate into position,locking the product's pins into the •Rotary switch tor horn;one and three vclume selections mounting plate's terminals.The device wiil remporarily hold in place •Outdoor producu UL listed to UL 1638(strobe)and UL 464(horn) with a catch until it is secured with a captured mountmg screw outdoor requirements •Outdoor produccs NEMA 4X rated The SpectrAlert Advance series indudes outdoor notification •Compatible w�th MOL sync module appliances Outdoor strobes and horn/strobes(two wire and four wire)are available for wall or ceiling.Outdoor homs are available for wall only All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrE�es Fahrenheit in wet or Agency Listings dry applications SIGNALING /i:5-I�;:I tlC(indW�SI�GLI��) 7.G0-16S5IBi W�I�OCr su:.Le�l u� F M MEA � I:5-165e 1851hoin/snobes approved �n�mr�:<<�tr:� LISTED APPROVED � ��ss-ivs3tnr0�arus,ch,me�1 :ann r„-z:� nnrnas�-ns-r sssiz �3593 SpectrAlert Advance Specifications General SpectrAlert Advance horns,strobes and horn/strobes shall mount to a standard 4 x 4 x 1/z-inch back box,4-inch octagon back box or double-9ang back box.Two-wire products shall also mount to a s�ngle-gang 2 x 4 x 1�/s-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.ihe nou(ica[ion appliance cucuit winny shall terrninate a[the universal mounung plate.Also,SpectrAlert Advance prod�cts,when used with the Sync•Grcuit"M�odule accesyory,shall be pewered(iom a non-ceded notification apphance u�cui[output and shall operate on a nominal 12 or 24 vol[s.When used with the SynoCircuit Module,12-volt rated notfication apphance arcuit outputs shall operate between nine and 17 5 volts,24-volt rated notification appliance arcwt outputs�hall operare between 17�nd 33 volt� In�ioor SpectrAlert Ad���nce producu thall operare between 32�r�d 120 degrees Fahrenheir trom a reaulated U�,or tull wave recuhed,unf�ltercd power supply Strobes and hom/strobes shall have held-sclectablc candefa sctUngs induding I5, I�//S,3U, ,'S,�5,110.115,13�,1�0,1�%,185 Strobe ThP 5(fclhP Sh�l��r7P d SYC1Pf71 SP�S(1(S�P�ifF��Pfi A('�V3nCP�/It�ljC'� �ISi2C�TO��� �9���7(1(�Shd��h2 dpFl(OVPC�{nf fl(P(�fOL2CtIVP S2fVICP ThP SirnhP$hd��hP wirPd as a primary-signalinr�n�nficanon appliancP and romply with the Americans with Disabihties Act requirPmenu for visihle vcinaling appliances,Flashing at 1 Hz over the strobe's entire operatinq voltage range The strobe light shall consist of a xenon Flash tube and assoaated lens/reFlector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpecuAlert Advance Model listed to UL 1971 and UL 464 and shall be approved to�fire protecuve service 7he hcm/s[robe shall be wued as a pi�mary-signahnq noufication appliance and comply with the Amencans with Disabdities Act reqwrements for vis�ble siynahng apphances,flashing aT 1 Hz over the strobe's enure opertmg voltage range.The strobe lighc shall consist of a xencn flash:ube and assoaaced lens/ie!le�tui�ystem Ilie hoin slidll have thiee audibility o�uuru and an opiion to switch between e tempuial three-pattein and d nun-tempoial(�onUnuous) pattem.These options are set by a multiple posihor.sw�tch On four-wire products,the strobe shall be powered independently of r�e sounder The horn on horn/strobe models shall operate on a coded or non-coded power supply Outdoor Products SpectrAlert Advance outdoor homs,strobes and hom/strobes shall be hsted for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenhert The produas shall be listed for use wrth a System Sensor outdoor/weatherproof back box with haff mch and trree-fourths inch condwt FntriPs Synchronization Module The module shall be a System Sensor SynoGrcuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at i Hz and homs at[emporal three.Also,wh�le operaung the strobes,the module shall silence the homs on horn/strobe models over a single pair of wires The module shall mount to a 4��i,a x 4�Y�6 x 2'/e-mch back box The module shall also control two Style Y(dass Bl arcwts or one Style Z (dass A1 arcwtThe module shall synchron¢e multiple zones Daisy chaining two or more synchrornzauon modules together will synchronize all the zones they control.The module shall nor operate on a coded power supply Standard Opereting Temperature 32°F to 120°F(0°C to 49°Q K Series Opereting Temperature —40"F to 151"F(-40"C to 66"C) Humidity Range 10 to 93%non-condens�ng(indoor products) Strobe Flash Rate 7 Flash per second Nominal Voltage Regulated 12DC1FWR or regulated"Z4DC/FWR' Operating Voltage RangeZ R to 17 5 V(1�V nominap or 1�to 33 V(J4 nominal) Input terminal wire gauqe 12 to 1 R AWG Ceiling mount dimensions(induding lens) 58 diameter K 2.5"hiqh(173 mm diameter x 54 mm high) Wall mount dimensions(induding lens) 5.6"L x 4J'W x 2.5"D(142 mm L x 119 mm W x fr1 mm D) Horn dimensions 5.6"L x 47 W x 13"D(142 mm L x 119 mm W x 3 3 mm D) Wall-mount back box skirt dimensions(BBS-2,BBSW-2) 5.9't x S.0"W x 22"D(1 S 1 mm L x 128 mm W x 56 mm D) Ceiling-mount back box skirt dimensions(BBS�-2,BBSCW-2) 7 1 diameter x 2 25 high(180 mm diamerer x 57 mm high) Wall-mount weatherproof back box dimensions(SA-WBB) S./'L x S.1"W x 2.0"D(14S mm L x 130 mm W x 5 mm D) Ceiling-mount weatherproof back box dimensions(SA-WBBC) 7 1 diameter x 2 0"high(180 mm diameter x 51 mm hiqh) Wall-mount trim ring dimensions(TR-H5,TRW-HS) 5.7"L x 4.8127/V x 035"D(146 mm L x 122 W mm x 9 D mm) Ceiling-mounttrim ring dimensions(TRC-HS,TRCW-HS) 6.9"diametcr x 035 high(176 mm diameter x 9 mm high) Notes: 1 Full Wave Recufied(FWR)voltage is a non-regulated,nme varying power source that is used on some power supply and panel ou_puts. 7 P,S,P�,and S�prnriuctt will��eratP at 12 V nominal only for 1 S and 15/75 cd nes-aa9s-oos UL Current Draw Data � . 8-77.5 Volts 16-33 Volts 8-77.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern d6 DC FWR DC FWR Standard 15' 123 1�8 66 71 Temporal High 57 55 69 75 CandelaRa�ge 15�7,� 142 �qg 77 81 Temporal Medium 44 q9 58 69 30* NA NA 94 96 Temporal �ow 38 44 �74 48 %5* NA NA 15R 153 Non-temporal High 57 56 69 75 a5* NA NA 1R1 17E, Non-Temporal Medium 42 � 50 60 69 I10 NA NA 202 1°S Non-temporal Low 41 44 50 50 175 NA NA 2�0 2u5 Coded H�gh 57 55 69 75 High 135 NA NA 228 207 Coded Med�um 44 51 56 69 Candela Range I SG NA NA 2-+6 220 Coded Low 40 46 52 50 177 NA NA 281 251 18S NA NA 286 258 � 8-17.5 Volts 16-33 Volts DC lnput 15 15/75 15 15/75 30 75 95 110 175 Temporal High 137 147 79 90 107 17E 194 212 z7g Temporal Mediuro 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 15� 91 100 116 176 201 221 Zz9 Non-temporal Medium 13; 145 75 85 102 163 187 2C7 216 Non-leinporal Luw 137 144 68 /y y6 156 181 101 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medwm 129 152 78 88 103 760 184 202 206 TemporalLow 12q 751 76 86 101 160 184 794 201 Non-temporal High 142 161 703 112 126 181 2G3 221 229 Non-temporal MP�lium 1 34 1 SS 85 95 110 1F,6 189 ?08 216 Non-temporal I ow 137 154 80 90 105 161 1&3 ?02 21 1 . 16-33 Volts 16-33 Volts DC Input 135 150 777 785 fWR In ut P 735 750 177 185 lempoial High 14S ZSy 1�0 19/ lem oial Hi h � P 9 1S 131 2S8 16S lernpoial Medwrn 13� ZS3 ��� 2y7 lempaal Medium 20J 224 250 258 Temporal Low 23�' 251 ?82 292 Temporal Low 207 Z21 248 256 Nomtemporal I liyh 2;; 270 303 309 Non-temporal f ligh 233 243 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 �62 267 Non-temporal Lov� 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low[empera[ures,listed candela ranngs must be reduced m accordance w�th this table �- � •- • 8-17.5 16-33 24 Volt Nominal Listed Candela Candela rating at-40°F Switch Volts Volts Reverberent Anechoic 15 Position SoundPattem dB DC FWR DC FWR DC FWR DC FWR 15/75 � Temporal High 78 78 84 R4 88 88 99 98 Do not use bclow 32"� 30 2 Temporal Medium 74 74 80 80 86 86 96 96 �S 3 Temporal Low 71 73 76 76 83 80 94 89 44 95 � Non-temporal Hfgh 82 82 gg gg 93 92 100 100 70 ��Q ��G S Non remporal Medium 78 78 85 85 90 90 98 98 115 c 6 Non-temporal Low 75 75 81 81 88 84 96 92 1L 135 �3� /' Coded Nigh 82 82 S8 �8 93 92 101 101 150 15G $' Coded Medium 78 78 SS tiS 90 90 97 98 ��� ��� 9- Coded Law 75 75 81 81 88 85 96 92 �85 'Settings 7,8,and 9 are not ava�lable on 2-wire hom/strobe. 18S AG�-0395-0�5 SpectrAlert Advance Dimensions �4.7' 2.5" _ 6.8" Dia. � 2.5" 5.6" --'__� Wall-mount horn/strobes Ceiling-mount horn/strobes 7.1' 225' /\ — 7..' 5.05"� �223�I Dia � � 2.0" ' Dia I � O �� OQ ��o Q �� o � o O �� 5.98' � e � 6.2' o p O O � O � o O O O Q � r {�—5.1'—•/ \� Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information .- �. Wall HornlStrobes Ceiling Horn/Strobes(co�Yd.) P2R*' 2 w�re Hom/Strobe,Standard cd',Red PC4W 4-w�re Horn/Strobe,Standard cd,White P2RH* 2 wue Hom/Strobe,High cd,Red P�4WH 4-wire Hom/Strobe,High cd,White P2RK"° 2-wire Hom/Strobe,Standard cd,Red,Outdoor Ceiling Strobes PZRHK" 2-wire Hom/Strobe,High cd,Red.Outdoor SCR" Svobe,Standard cd,Red P2W* 2-wne Horn/Strobe,Slanda�d cd,White S�RH` Slrobe,High cd,Red P2WH` 2-vvue Hurn/St�ube,Hiyh�d,Whne S�RK° Strobe,Standard�d,Red,OutUOOi P4R* 4-wire Hom/Strobe,Standard cd,Red SCRHK° Strobe,High cd,Red,Outdoor P�RI I' 1-wlrc!lom/Strobc,I liqh cd,Red SCW"" Strobe,Standard cd,White P�IRK` 4-wire I lom/Strobc,Standard cd,Red,Outdoor SCWI I`f Strobe,I ligh cd,White P4RHK° 4wire Horn/Strobe,High cd,Red,Outdoor Horns P4W* 4-wire Norn/Strobe,Standard cd,White HR Horn,Red P4WH* 4 wire Horn/StrobP,Hiqh�d,WhitP HRK° Hom,Red,Outdoor Wall Strobes HW Horn,White SR*' Strobe,Standard cd,Red Accessories SRH" Strobe,H�gh cd,Red BBS 2 Back Box Skirt,Wall,Red SRK° Strobe,Stardard cd,Red,Outdoor BBSW-2 Back Box Skirt,WaII,White SRHK Strobe,High cd,Red,Outdoor BESC-2 Back Box Skirt,Ceiling,Red SW* Shube,Siandaid ccJ,White BBS�W-1 Bdck Box Sknt,Ceiliny,Whrte SWH' SUObe,High�a,Whrte IR-HS Inm Rirg,Wall,Red Ceiling Horn/Strobes TRW-HS Trim Ring,Wall White PC2R" 2-wirc I lom/Strobc,Standard cd,Rcd 7RC-I IS Tnm Ring,Cciling,Red I'C2RI I* 2-wirc i lom/Strobe,!ligh cd,Red TRCW-I IS Trim Ring,Ceiling,White PC2RK° 2-wire Nom/Strobe,Standard cd,Red,Outdoor Notes: PCJRHK° 7-wira Horn/SrmbP,Hiqh rd,Red,nutdoor "Add"-P'to model number for plain housino(no",IRE"marking on cover),eg, PCZW* J-wirP HorNStrobe,Standard cd,WhitP P%R-P PQWH* 2-wire Hom/Strobe,High cd,White t Aci�l"-SP"ro modPl numbPr for"FUEGO"marking nn c�ver,e.g.,P2R-SP PC4R 4 wire Hom/Strobe,Standard cd,Red �°Standard cd"refers to snobes that indude 15,15/75,30,75,95,710,and 115 candela setnngs."H�gh cd°refers to strobes that indude 135,150,177,and 185 PC4RH 4-wire Hom/Strobe,High cd,Red candela settings P�4RK 4-wire Hom/Strobe,Standard cd,Red,Outdoor All o�tdoor un�ts ending in"K"mdude a weatherproof back box PC4RHK° 4-w�re Hom/Strobe,H�gh cd,Red,Outdoor �Add"-R"to model number for weatherproof replacement device(no back box induded) � SYSTEM m:oof�5�s�em:��=o� �� SE/VSORe 3825 Ohio Avenue•St Charles,IL 60174 a,�e�s�mcao�-�wq.a�.m��o�ewimo�irn�xi�=visrt:vscem�_���<�r� Phone 800-SENSOR2•Fax 63U-377-6495 <«e^�P����a��f�ma,�,,��<i�w��9mei,�e«„e,,,,,,,,rm�saa�r�n=� A05-039'-0'S e�'P x2G19 df-52385:A•E-710 1�1355(Aj Series Fl�•��T��Alc�l''t1''1S Intelli � gent Addressable Thermal by Honeywell Detectors � . General The Fire�Lite Alarms H355 Series thermal detectors are addressable sensors that use a state-of-the-art thermistor � sensing circuit for fast response. These sensors are designed to provide open-area protection and are intended for use with the Fire�Lite's addresable Fire Alarm Control Panels(FACPs). ' The H355(A) and H355R(A) sensors provide fixed tempera- � � ture alarm detection at 135°F (57°C). The H355R(A) sensor �3�o,p also responds to rate-of-rise conditions of greater than 15°F r (8.3°C) per minute. The H355HT(A) is a fixed high-tempera- �� ture detector that activates at 190°F (88°C). These thermal � detectors provide cost effective, addressable property protec- � tion in a variety of applications. H355 with B350LP base Two LEDs on each sensor light to provide a local,visible sen- sor indication. Remote LED annunciator capabiliry is available as an optional accessory(P/N RA400Z). • 94-5V plastic flammability rating. F@BtYf"eS Options: SLC loop: • Remote LED output connection to optional RA400Z • Two-wire SLC loop connection. remote LED annunciator. • Unit uses base for wiring. • Recessed (RMK400) or surface (SMK400E) base mount- Addressing: ing kits. • Addressable by device. Installation • Direct Decade entry of address:01 —159 with MS-9600,Ot —99 with MS-9200UD. H355(A) Series plug-in intelligent thermal detectors use a Architecture: detachable base to simplify installation, service and mainte- nance.Installation instructions are shipped with each detector. • Sleek, low-profile,stylish design. Mount base (all base types) on box that is at least 1.5' (3.81 • State-of-the-art thermistor technology for fast response. cm)deep.Suitable boxes include: • Integral communications and built-in device-type identifica- . 4.0"(10 16 cm)square box. tion. Built-in tamper resistant feature. • 3.5'(8.89 cm)or 4.0'(10.16 cm)octagonal box. • Built-in functional test switch activated by external magnet. ' Single-gang box(except relay or isolator base) Operaflon: NOTE:Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring `T-taps" or • Factory preset at 135°F (57°C) for the H355(A) and branches are permitted for Sty/e 4(C/ass`B')wiring on/y. H355R(A); 190°F(88°C)for the H355HT(A). • Rate-of-rise triggers at 15°F (8.3°C) per minute for the APP��cations H355R(A). Use thermal detectors for protection of property. • 360°-field viewing angle of the visual alarm indicators (two bicolor LEDs). LEDs blink green in Normal condition and Construction turn on steady red in Alarm. • Visible LEDs"blink"every time the unit is addressed. These detectors are constructed of off-white BayblendC�. The H355(A) Series plug-in intelligent thermal detectors are Mechan/cals: designed to commercial standards and offer an attractive • Sealed against back pressure. appearance. • SEMS screws for wiring of the separate base. • Designed for direct-surface or electrical-box mounting. �peration • Plugs into separate base for ease of installation and main- Each H355(A) Series detector uses one of 159 (MS-9600)or tenance. 99(MS-9200UD) possible addresses on a control panel SLC • Separate base allows interchange of photoelectric, ioniza- loop. It responds to regular polis from the control panel and tion and thermal sensors. reports its type and the status. If it receives a test command Othersysiem features: from the panel (or a local magnet test), it stimulates its elec- tronics and reports an alarm. It blinks its LEDs when polled • Remote test feature from the panel. and turns the LEDs on when commanded by the panel. The • Walk test with address display. H355(A) Series offers features and performance that repre- • Low standby current. sent the latest in thermal detector technology. df-5238S:A•12/17/08—Page 1 of 2 Specifations Product Line Information Diameter:6.1'(15.5 cm)installed in B350LP(A) NOTE:A"suffix indicates ULC-Listed model. Height:2.1'(5.33 cm). H355: Intelligent thermal sensor;6350LP base included. Weight:4.8 oz.(137 g). H355A: Same as H355 but with ULC Listing (6350LPA base Installation temperature: �°F to 100°F(-20°C to 38°C). included). Humidity range: 10% to 93% relative humidity (noncon- H355R:Same as H355 with rate-of-rise feature;6350LP base densing) included. Voltage range: 15 to 32 VDC peak. H355RA: Same as H355R but with ULC Listing (B350LPA base included). Standby current: 300 NA � 24 VDC (one communication H355HT: Intelligent fixed high-temperature thermal detector; every five seconds with LED blink enabled). B350LP base included. LED current:6.5 mA� 24 VDC. H355HTA: Same as H355HT but with ULC Listing (6350LPA Mounting: B350LP(A)flanged base, included. base included). Fixed-temperature setpoint: 135°F (57°C) for the H355(A) B350LP(A): Plug-in detector base (included). Dimensions: and H355R(A); 190°F(88°C)for the H355HT(A). 6.1" (15.5 cm). Mounting:4.0°(10.16 cm)square box with or Rate-of-rise detection:responds to greater than 15°F(8.3°C) Without plaster ring, 4.0' (10 16 cm) octagonal box, 3.5" (8.89 per minute. cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5'(3.81 cm). Listings and Approvals B224R6(A): Plug-in System Sensor relay detector base. Listings and approvals below apply to the H355(A) Series Dfameter:6.2'(15.75 cm). Mounting:4.0"(10.16 cm)square detectors. In some cases, certain modules may not be listed box with or without plaster ring,4.0'(10 16 cm)octagonal box, or 3.5' (8.89 cm) octagonal box. All mounting boxes have a by certain approval agencies, or listing may be in process. minimum depth of 1.5"(3.81 cm). Consult factory for latest listing status. MEA approved:file 387-02-E B224BI(A): Plug-in System Sensor isolator detector base. � Maximum 25 devices between isolator bases(see DF-52389). • UL Listed,file S2517 Dlameter.6.2"(15.75 cm).Mounting:4 0'(10.16 cm)square • ULC Listed(models H355A,H355RA, H355HTA) box with or without plaster ring,4 0'(10 16 cm)octagonal box, • CSFM approved:file 7270-0075:195 or 3.5' (8.89 cm) octagonal box. All mounting boxes have a FM approved minimum depth of 1 5'(3.81 cm) • B501 BH-2(A): Plug-in System Sensor standard sounder base. Diameter:6 0" (15.24 cm). Mounting:4.0' (10.16 cm) square box with or without plaster ring. Mounting boxes have a minimum depth of 1.5'(3.81 cm). B501 BHT 2(A): Plug-in System Sensor temporal tone sounder base. ACCESSOR/ES: RA400Z(A): Remote LED annunciator.3-32 VDC. Mounts to a U S. single-gang electrical box. For use with B501(A) and 6350LP(A)bases only. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with 6501(A)base only. RMK400: Recessed mounting kit. For use with 6501(A) base only. M02-04-0O:Test magnet. M02-09-00:Test magnet with telescoping handle. XR2B: Detector removal tool.Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR2B. Comes in three 5-foot(1.524 m)sections. Fire�Lite�Alarms is a registered trademark of Honeywell International Inc. Bayblend�is a registered trademark of Bayer Corporation. �2008 by Honeywell International Inc. All rights reserved.Unauthorized use of this document is strictly prohibited. ' O� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. . We cannot cover all specific applications or anticipate all requirements. ����� All specifications are subject to change without notice. l�AIITr S�8TEMS For more information,contact Fire�Lite Alarms.Phone:(800)627-3473,FAX.(877)699-4105. www.firelite.com Page 2 ot 2-df-52385:A•12/17/08 � Y Jacqueline Boges � To: Julie Diaz Subject: inspection for city zephyrhills 38112 15th ave Attachments: fire inspection.pdf Hey Julie, I have a inspection needed for fire alarm system for a daycare the is located on 38112 15`h Ave . The contractor is requesting inspection for tomorrow Friday 3'd no time was given. If the inspector has a time great if not no worries. See the attachment for inspection comments and required inspection needed per Chief Williams. The contractor also should have plans and permit card on site for the inspection to be done. Company is MGQ&Associates inc. Contractor is Mani phone number is 813-454-9602. Let me know if you need anything else Julie. Thanks Jackie Boges Code Support Specialist ext. 3513 i NOTE1 Subscript at strobes and speaker /strobes denotes candela based on NFPA 72 (1996) and UL 1971, SYMBOL FACP FAAP FAT( P'NR 15th Ave. POWER EXPANDER PANEL F—F] MANUAL STATION EXISTING MANUAL STATION 7 HEAT DETECTOR ❑s SMOKE DETECTOR 0 © DUCT SMOKE DETECTOR -- PLENUM SMOKE DETECTOR la a DH cF GENERATOR FAULT 48' TO TOP OF BOX - DEEP 1900 W/ SINGLE GANG GS DEVICE RING OR OLD WORK BOX 8B BOX OR SINGLE GANG BOX 8B BOX OR SINGLE GANG BOX 0 SEE INSTALLATION INSTRUCTIONS O 1900 BOX, 88 BOX OR SINGLE GANG BOX GENERATOR START KITCHEN HOOD COMPUTER ROOM SYSTEM SPRINKLER FLOW VALVE TAMPER REMOTE INDICATOR LIGHT SINGLE GANG BOX MOUNTED IN ACCESSIBLE AREA MONITOR MODULE (SINGLE ZONE) LOCATED AT AN ACCESSIBLE LOCATION NEAR DEVICE SERVED - DEEP 1900 BOX - SERVED DEEP 1900 BOX STROBE DEEP 1900 BOX OR TWO GANG OLD WORK BOX, MOUNTED SO THAT THE ENTIRE LENS IS BETWEEN 80' - 96' A,FF MONITOR MODULE (TWO ZONES) LOCATED AT AN ACCESSIBLE LOCATION NEAR DEVICE SERVED - DEEP 1900 BOX DEEP 1900 BOX WITH 1 1/2' EXTENSION RING HORN / STROBE DEEP 1900 BOX OR TWO GANG OLD WORK BOX, MOUNTED SO THAT THE ENTIRE LENS IS BETWEEN 80' - 96' AFF CONTROL MODULE RELAY MODULE DOOR HOLDER ® FIRE PUMP RUN © FIRE PUMP FAULT KN07X FIRE DEPARTMENT KNOX BOX - -__ — LOCATED AT AN ACCESSIBLE LOCATION NEAR DEVICE HORN DEEP 1900 BOX OR TWO GANG OLD WORK BOX, MOUNTED SO THAT THE TOP OF THE DEVICE IS NOT LESS THAN 90' A,F.F. - SERVED DEEP 1900 BOX - AND NOT - LESS -_THAN 6'- BELOW - THE_ INISHED CEILING ACCESSIBLE AND WITHIN 3 FEET OF DEVICE SERVED O SPEAKER DEEP 1900 BOX WITH 1 1/2' EXTENSION RING - DEEP 1900 BOX � SPEAKER / STROBE DEEP 1900 BOX WITH 1 1/2' EXTENSION RING D FIREFIGHTERS PHONE — 0 JUNCTION BOX ANN ANNUNCIATOR 01 20 5 ;o 1 1 C �C • L a Q �7 r� <; � f 3 N ct �>, n r I Issue Date: 7/12/12 1 Revisions No, I Date , Description MGQ & Associates, Inc. 1719 E. Columbus Drive Tampa, FL, 33605 Tel (813) 877 -8895 Fax; (813) 877 -8777 Project Number: Drawn By: P.J, Designed By: MGQ & ASSOCIATES, INC. Bright Beginnings Day Care 60/ 38112 15th Ave, Zephryhills, FL. 33542 Sheet Number. F -1