HomeMy WebLinkAbout12-13418 CITY OF ZEPHYRHILLS
' S335-8TH STREET �
(si3)�so-oo20 13�18
BUILDING PERMIT
Permit Number: 13418 Address: 38225 12TH AVE
Permit Type: RE-ROOF ZEPHYRHILLS, FL.
Class of Work: ROOF REPLACEMENT Township: Range: Book:
Proposed Use: COMMERCIAL Lot(s): Block: Section:
Square Feet: Subdivision: CITY OF ZEPHYRHILLS
Est. Value: Parcel Number: 11-26-21-0010-03300-0130
Improv. Cost: 33,520.00
Date Issued: 9/06/2012 Name: CARRIAGE TRADE DRY CLEANERS
Total Fees: 307.50 Address: 38225 B 12TH AVE
Amount Paid: 307.50 ZEPHYRHILLS,FL. 33542
Date Paid: 9/06/2012 Phone: (813)788-9808
Work Desc: REROOF SYSTEM TIMBERLINE HD
l 1��
�` � c�^
�
� �
�
�
z
TAPE JOINTS RO IN�P ''
FINAL_IQ �� v�
REINSPECTION FEES: Reinspection fees will wmply with Florida Statute 553.80 (2)(c)when extra inspection
trips are necessary due to any one of the following reasons: a)wrong address b)condemned work resulting
from faulty wnstruction c) repairs or wrrections not made when inspections called d)work not ready for
inspection when called e) permit not posted on job site f) plans not at job site g)work not acxessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this counry, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications Must Accompany Application.All work shall be pertormed in acwrdance with
' Codes and Ordinances. NO OCCUPANCY BEFO C.O.
�
�
C NTRACTOR SIGNATURE PERMIT OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
.`��S��S�-�'�h��7
� � �
"�.� �:�&J.� ��i�>
�e-
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
/ 6
�ontrac omeowner: �,Z,� '� � � _: -� G7� '
, �
Date Received: ,Q�'<��f�/-.;L
1
� �N
Site: �•.����`� "` /'� = ��,
Pernut Type: �,�,'� � � Cy-�yr` � � �.��.c'�
�• �/n
--�'� l�� ��'�r`/'% f•
Approved w/no comments: Approved w/the below comments: ❑ efued w/the below comments: ❑
This comment sheet shall be kept with the peimit and/or plans.
�i
Kalvin witzer— Examiner Date Contractor and/or Homeowner
(Required when comments are present)
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department �
, " ��� � ��� , 3�(
DateReceived �� �� phoneContactforPertnittin 813 �82 __ 9080 I
Owner'sName CARRIAGE TRADE INC OwnerPhoneNumber 813-788-980�9
�
Owner'sAddress 38225 12TH AVE, ZEPHYRHILLS, FL 335 2 OwnerPhoneNumber �-�
Fee Simple Titleholder Name Owner Phone Number ��
Fee Simple 7itleholder Address
JOBADDRESS 38225 12TH AVE, ZEPHYRHILLS, FL 33542 LOTM �
SUBDIVISION PARCELID# 11-26-21-0010-03300-0130
(OB7AINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED e NEW CONSTR e ADD/ALT � SIGN Q Q DEMOLISH
INSTALL REPAIR
PROPOSED USE Q SFR QX COMM � OTHER
TYPE OFCONSTRUCTION Q BLOCK Q FRAME � STEEL Q
DESCRIPTION OF WORK TEAR OFF EXISTING ROOF SYSTEM AND REPLACE WITH TIMBERLINE HD ROOF
BUILDING SIZE �� SQ FOOTAGE 7252 HEIGHT �
QBUILDING�ROOFIN VALUATION OF TOTAL CONSTRUCTION
33,520.00
QELECTRICAL $ AMP SERVICE Q PROGRESS ENERGY Q W.R.E.C.
�PLUMBING $
�MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION -
QGAS XQ ROOFING Q SPECIALTY 0 OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA QYES NO
+�1� �
BUILDER OMPANY JASON NEUMANN/NEUMANN ROOFING
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address 30427 COMMERCE DR, SAN TONIO, FL 3 576 License# CCC1326166 �
ELECTRICIAN COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREI. Y/N
Address License# ��
PLUMBER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License#
MECHANICAL COMPANY �
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License# ��
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License# �-�
1111111111111111111111111111111111111111111111111111111111111111111
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-0-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construchon Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdrvisionsllarge pro�ects
COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construchon Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities 8 1 dumpster Site Work Pertnit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
""PROPERTY SURVEY required for all NEW construction
• • • • • ' 1 1 1 1 1 1 i 1 • 1 1 1 1 I 1 1 1 1 1 i �� •
Directions:
Fill out application completely
Owner&Contrector sign back of application,notanzed
If over E2500,a Notice of Commencement is required. (A/C upgrades over 57500)
" Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (Front of Application Only)
Reroofs if shingles Sewers Serwce Upgrades A/C Fences(PIOUSurvey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
, NOTICE OF DEED RESTRICTIONS. The undersigned understands that this permit may be subject to"deed"restrictions"
� which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES. If the owner has hired a contractor or
contractors to undeRake work,they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009 Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County
TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES. The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees,as may be due,will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or
final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500 00 or more,I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to�
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls,Docks,Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V"unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume"will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction,I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating
the conditions of the building permit issued under the attached permit application,for lots less than one (1)
acre which are elevated by fill,an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, welis, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or
set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by
the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension
may be requested, in writing,from the Building O�cial for a period not to exceed ninety(90)days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LEND OR AN ATTORNEY BEFORE RECORDING YOU OTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S. 17. ) �
OWNER OR AGENT V- J
CONTRACTOR
S cri and sw rn t or affirmed)b ore e this b cribe and swor o(or affirmed before me this
—��bY � � 1'�by ASON W. �EUMANN
Who is/are personally known to me or has/have produced Who is/are personally known to me or has/have produced
as identification. PERSONAI,LY KNOWN as identifcahon.
� �
C � � ' �
Notary Public _NOtary Public
Commission No.�C� V �� J
Commission No.
�J a1� : 1. 1C�1 ��1"}�f-'. L �(f�
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
����� RB�IEE C.RICH ,�t��� REFIEE C.RK�H
� MY COMMISSION 1 EE�T5996 � MY COMMISSION 1 ff d75A96
�OF� °Ofl�I�+�►►�a.rs�o� ��R� eon�an�wdN��a.rs�wo�
Permit Packa�e Instruction Sheet
._ � Z �11 S
Job Name: l. � C� _� � Job #: �''3� b permit Refere�ce #:
Permit Area: 2 1 �5 Issued Permit #:
Step 1. Initial Drop Off& Recording of NOC Step 3. Dropping Off Completion Reports
Payment arranged? Yes�No A. Hillsborough County
Payment Type Amount $ � . payment arranged for Clerk's recording of
�
completion package? Yes No
MapQuest from Clerk to B. D.? Yes�No
Special MapQuest made? Yes�No Payment Type Amount$
Hillsborough Completion Instructions and/or
Permit Drop off Instructions and/or Comments: Comments:
- i� �C�d� 1�C�G
-- S v � Y
B. Other Counties
Step 2. Picicr�l�� ut� Issue�! Pe�•ysiits
Completion Instructions and/or Comments:
Payment arranged? Yes No
Payment Type Amount $
MapQuest from Clerk to B. D.? Yes No
Special MapQuest made? Yes No
Permit Pick up Instructions and/or Comments:
OPTIONAL. Other Work
B. Extensions, etc.
Instructions and/or Comments:
�ONTACT PERSON
- FOR PERMIT ARPLICATlON �
� � �
ONTROL # DATE: � J
NAME: � � I (J�� f
.
COMPANY: �� rn � ��D� \ �,�
(
PHONE: � � � �� - q C�a
, �
I'
CELL PHONE: � � � ��,(Ic�= � '�j(� `� '
i
FAx:_ J,--� - (o(1J S�- �-� v�
J �
�-MA�L ADDRESS: (,() Q � �h � � �
NOTES; �
THE CONTACT P�ERSON WILL BE CONTACTED FOR CORRECTIONS� ERRORS,
ADDITIONAL INFORMATION, ETC.
FBC 104.1.6 TIME LIMiTATIONS. AN APPL�ICATION FOR A PERMIT
FOR ANY PROPOSED WQRK SHALL BE DEEMED TO HAVE BEEN �
ABANDONED fi MONTHS AFTER THE DATE OF FILING FOR THE PERMIT,
UNLESS BEFORE THEN A PERMIT HAS BEEN ISSUED.
. . I�
I
��,
State of Florida License#CCC1326166 and # CBC058155
30427 Commerce Drive, San Antonio, FL 33576
Phone (813) 782-9080 /Fax (352) 668-4803 /www.neumannroofs.com
Apri12, 2012
Carriage Trade Drycleaners
Attn: Karen Benoit
38225 12th Avenue
Zephyrhilis, FL 33542
813-788-9808
RE: REVISED ESTIMATE/CONTRACT— TIMBERLINE HD ROOF & FLAT
ROOF
Neumann Roofing, LLC proposes to furnish labor, material, supervision, equipment, fees and other
costs related to the completion of the subject property; specifications listed below:
1. Record Notice of Commencement and obtain all required permitting.
2. Tear-off existing roof system down to deck substrate and re-nail roof deck to meet State Of
Florida Building Code.
3. Provide and install Peel & Stick Underlayment
4. Provide and install new drip edge around entire perimeter, matching the existing face
dimension. Color: TBD
5. Strike lines to ensure a uniform shingle installation.
6. Provide and install new GAF ProStart Starter Strip at drip edge system.
7. Provide and install new GAF Timberline HD Shingles with stain guard.
Color: TBD Squares: 59 Pitch: 9/12
8. Provide and install GAF Cobra Rigid Vent 3 on ridges. Vent will be covered with ridge cap
shingle to match roof system.
9. Provide and install GAF SeaI-A-Ridge Ridge Cap Shingles.
10. Provide and install new 16"valley metal in all valleys.
11. Provide and install new lead boots at plumbing vents. Boots will be painted to match
specified roof color.
12. Provide and install new gooseneck vents. Vents will be painted to match specified roof
color.
�
�
� �
�'Ei�e
FL License#: CCC1326166 GAF License#:ME20454
State of Florida License #CCC1326166 and # CBC058155
30427 Commerce Drive, San Antonio,FL 33576
Phone (813) 782-9080/Fax (352) 668-4803 /www.neumannroofs.com
13. Sweep magnets around the perimeter area of work to collect loose nails, staples, and other
various scrap sheet metal components.
14. Haul away all roof-related debris.
15. Our liability insurance coverage is based on completed operations.
16. Provide a GAF Weather Stopper System Plus Limited Warranty with upgraded wind
warranty up to 130 MPH (Free of charge).
17. All estimates/contracts are subject to Building Department approval in the appropriate
county/city. �
18. Payment schedule: Full amount for all work completed is due at job completion.
FLAT ROOF:
1. Clean and prep roof
2. Apply Apoc 525 thermoplastic surface compound
3. Level and smooth compound until dry
4. Apply#7 tan rock over product to a depth of about 2"
5. Find and repair problem areas on coping
6. 10 year manufacturer warranty
7. 5 year workmanship warranty
Unit Pricin� Schedule for Unforeseen Conditions:
1. Replace any rotted or damaged decking $45.00 per sheet. (Neumann Roofing provides 1-
sheet of 4'x8' plywood; included in contract price).
2. Replace any rotted fascia or perlins $4.50 per lineal ft.
Neumann Roofin�'s Commitment to Ouality•
• All work will be supervised by project managers to ensure quality work is preformed
according to our proposed contract.
• All work will be completed in a timely manner, excluding acts of nature beyond our control.
• All carpentry wark will be performed in conjunction with roofing work, in a timely manner
following general workmanship quality.
. e
� �EIRe
�wwao
FL License#: CCC1326166 GAF License#: ME20454
State of Florida License #CCC1326166 and # CBC058155
30427 Commerce Drive, San Antonio,FL 33576
Phone(813) 782-9080/Fax (352) 668-4803 /www.neumannroofs.com
• All work will be completed by skilled and knowledgeable craftsman to ensure production of
high quality of work.
• The job-site will be kept free of debris throughout the duration of the project.
• The perimeter of the project area will be swept with magnets to pick up any loose nails,
staples, or other various scrap sheet metal components.
• Any existing gutters will be cleaned of all organic and roof related debris prior to project
close-out.
• Neumann Roofing, LLC. is fully insured with workman compensation and general liability
insurance.
It is understood and agreed the Neumann Roofing,LLC will be held harmless for alleged or actual damages/claims as a
result of algae, fungus, or mold. It is understood the roofing contractor and the roofing contractor's insurance will
exclude all coverage, including defense, damages,related to bodily injury,property damage and clean up directly or
indirectly in whole or in part for any action brought by mold, including fungus and mildew regardless of the cost, event,
product or workmanship that may have contributed concurrently or in any sequence to the injury ar damage occurs.
"This document has been prepared for those parties financially responsible for services rendered. Reliance upon this
document or upon information,observations or opinions contained herein should not be made by any party other than the
intended recipient designated on the title sheet of this estimate or report. The intent of this evaluation is to prepare an
opinion of the probate scope and/or cost of work to be performed based upon the parameters set forth by the client and
the individual needs and conditions found within the structure at the time of inspection. This opinion assumes a specific
scope and methodology. The user is cautioned that changes in either scope or methodology would have a reciprocal
effect on this opinion. If this should occur,we reserve the right to review such changes and then modify our opinion
accordingly. Furthermore our opinion assumes resulting work will be competitively bid and,as such, it is advisable to
solicit multiple bids for such work."
SHINGLE ROOF WARRANTY:
SYSTEM PLUS/WEATHER STOPPER LIMITED WARRANTY:
• 130 MPH Wind Warranty
• 50 Year 100%Material Replacement—Defective Materials Only
• 50 Year 100% Labor to Install—Applies to Defective Materials Labor Only—Does Not Cover
Labor for Application Defects
• 2 Year 100%Workmanship/Labor—Provided by Neumann Roofing
• FREE One Time Only Transfer of Owners
� 0
�°-�- ��E�e
FL License#: CCC1326166 GAF License#: ME20454
�
State of Florida License #CCC1326166 and # CBC058155
30427 Commerce Drive, San Antonio, FL 33576
Phone(813) 782-9080/Fax (352) 668-4803 /www.neumannroofs.com
SHINGLE ROOF TOTAL: $ 16,520.00
FLAT ROOF TOTAL: $ 17,000.00
TOTAL FOR BOTH ROOFS: $ 33,520.00
• 100% payment due upon job completion.
• Proposed price is valid for 30 days from proposal date. Subject to price increases after
30 days.
• In the event it is necessary to collect any amount of money owed hereunder by referral
to an attorney, collection agency, or court proceeding, it is agreed that Neumann
Roofing, LLC shall be entitled to reimbursement for all costs of collection of unpaid
amounts by Owner/Agent and for reasonable attorney's fees and costs for the breach,
or enforcement of any terms of this entire service agreement. A service charge of 1.5°/a
per month will be due on all invoices thirty (30) days past due.
Accepted By: � Neumann Roofing, LLC
� �!�+7R�i�"--
Date: �' �f�I Z Date: �/��>�
� ' m
�
...�.�
FL License#: CCC1326166 GAF License#: ME20454
rr
State of Florida License #CCC1326166 and #CBC058155
30427 Commerce Drive, San Antonio,FL 33576
Phone (813) 782-9080/Fax (352) 668-4803 /www.neumannroofs.com
CONSTRUCTION LIEN LAW
Florida State Statutes 713.015: Mandatory provisions for direct contracts. (1) Any direct contract greater
than $2,500 between an owner and a contractor, related to improvements to real property consisting of
single or multiple family dwellings up to and including four units, must contain the following notice provision
printed in no less than 12-point, capitalized, boldfaced type on the front page of the contract or on a
separate page, signed by the owner and dated:
ACCORDING TO FLORIDA'S CONSTRUCTION LIEN LAW (SECTIONS 713.001-713.37, FLORIDA STATUTES),
THOSE WHO WORK ON YOUR PROPERTY OR PROVIDE MATERIALS AND SERVICES AND ARE NOT PAID IN
FULL HAVE A RIGHT TO ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR PROPERTY. THIS CLAIM IS
KNOWN AS A CONSTRUCTION LIEN. IF YOUR CONTRACTOR OR A SUBCONTRACTOR FAILS TO PAY
SUBCONTRACTORS, SUB-SUBCONTRACTORS, OR MATERIAL SUPPLIERS, THOSE PEOPLE WHO ARE OWED
MONEY MAY LOOK TO YOUR PROPERTY FOR PAYMENT, EVEN IF YOU HAVE ALREADY PAID YOUR
CONTRACTOR IN FULL. IF YOU FAIL TO PAY YOUR CONTRACTOR, YOUR CONTRACTOR MAY ALSO HAVE A
LIEN ON YOUR PROPERTY. THIS MEANS IF A LIEN IS FILED YOUR PROPERTY COULD BE SOLD AGAINST
YOUR WILL TO PAY FOR LABOR, MATERIALS, OR OTHER SERVICES THAT YOUR CONTRACTOR OR A
SUBCONTRACTOR MAY HAVE FAILED TO PAY. TO PROTECT YOURSELF, YOU SHOULD STIPULATE IN THIS
CONTRACT THAT BEFORE ANY PAYMENT IS MADE, YOUR CONTRACTOR IS REQUIRED TO PROVIDE YOU
WITH A WRITTEN RELEASE OF LIEN FROM ANY PERSON OR COMPANY THAT HAS PROVIDED TO YOU A
"NOTICE TO OWNER." FLORIDA'S CONSTRUCTION LIEN LAW IS COMPLEX,AND IT IS RECOMMENDED THAT
YOU CONSULT AN ATTORNEY.
(2)(a) If the contract is written, the notice must be in the contract document. If the contract is oral or
implied, the notice must be provided in a document referencing the contract.
(b) The failure to provide such written notice does not bar the enforcement of a lien against a person who
has not been adversely affected.
(c) This section may not be construed to adversely affect the lien and bond rights of lienors who are not in
privity with the owner. This section does not apply when the owner is a contractor licensed under chapter
489 or is a person who created parcels or offers parcels for sale or lease in the ordinary course of business.
, r
Accepted and Approved: /��h�'' �'j1�CJr�� �''(f /Z
P T NAME DATE
' �
�� Client Initials �� Neumann Officer
� a �
� ��
FL License#: CCC1326166 GAF License#: ME20454
Flarida Building Code Online Page 1 of 2
. ,
.
: . ' � � . � � . �
r� . �
F���,da D�p�,�"'Tl�'1��' BCIS Home Log In User Registration Hot Topics Submit Surcharge 5 a Pubiications FBC Staff BCIS Site Map �Links Search
h^"�'
Busines � ,h -
Professi��t�l Product Approval
USER.Public User
Regulatic�n ` . '
� � Product Aoproval Menu>Produd or Aoolication Search> li ion Li t>Application Detail
EVIEW DNTt_ Z
, , FL# FL10124-R7 �-�y OF ZEPHYRHILI_S �
. Application Type Editorial Change ��
code versio� 20�o PLANS E�AMINER ,_�.___.
Application Status Approved
Comments
Archived
Product Manufacturer GAF
Address/Phone/Email 1361 Alps Road Lw�IU{SHALLCOMPLYWITHAL
Wayne, NJ 07470 �
(973) 872-4421 p�,VAILING CODES,FCT����D�ANA
lindareith@trinityerd.com CODE,NATIONAL�L� �����
Authorized Signature Beth McSorley
C1TY OF ZEPHYRHILL5 ORI��
li ndareith@tri nityerd.com
Technical Representative Beth McSorley
Address/Phone/Email 1361 Alps Road - Bldg 11-1
Wayne, NJ 07470
(973) 872-4421
BMcSorley@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who Robert Nieminen
developed the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 02/06/2013
Validated By ]ohn W. Knezevich, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL10124 R7 COI Trinitv ERD CI - Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 (Class F) 2006
ASTM D3462 2007
ASTM D7158 (Class H) 2007
TAS 107 1995
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBe VCbdMQNZD6... 8/20/2012
Florida Building Code Online Page 2 of 2
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/04/2012
Date Validated 04/25/2012
Date Pending FBC Approval 04/29/2012
Date Approved 06/il/2012
Summary of Products
FL# Model, Number or Name Description
10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab, laminated, 5-tab and
hip/ridge asphalt shingles
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL10124 R7 II er041912FINAL GAF Asohalt
Approved for use outside HVHZ:Yes Shinales FL10124-R7.odf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Refer to ER, Section 5. Evaluation Reports
FL10124 R7 AE er041912FINAL GAF Asohalt
Shinqles FL10124-R7.odf
Created by Independent Third Party: Yes
Back Next
Contact Us : 1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer Coovriqht 2007-2010 State of Florida. Privacv Statement: Accessibilitv Statement Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not
send electronic mail to this entity Instead,contact the o�ce by phone or by traditional mail.If you have any questions,please contact 850.487.1395.
*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department
with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public
rxord.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.
To determine if you are a licensee under Chapter 455,F.S.,please click here
Produd Approval Accepts:
� � �
�� 5ecxirit s�t,cx[cs
� ti SEt.k3R£0 '
� �
,, .,�<<E:,v.a�sqn
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeV CbdMQNZD6... 8/20/2012
EXTERIOR RESEARCH & DESIGN, LLC.
� Certificate of Authorization #9503
�. TRINITY� 353 CHRISTIAN STREET, UNIT #13
ERD OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
GAF Evaluation Report 01506.01.08-R9
1361 Alps Road, Building 7-3 FL10124-R7
Wayne, N) 07470 Date of Issuance: 01/03/2008
Revision 9: 04/19/2012
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 Florida Building Code sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. Trinity�ERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words °Trinity�ERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 4.
Pre ared b .�����«�.,, --
P Y� o�a•a� +,,...,�•,,a�
. %.
�,r...- :p���''+E•ti t:'��1•.
ax�:�ro-s�tas�'%.
'�e a
� . i�- The facsimile seal appearing was authorized
��= �q;-: pf �� by Rabert Nieminen,P.E.on 04/19/2012
•,����;�.�^�tiQ�r, This does not serve as an electronically signed
��at s=• document. Signed,sealed hardcopies have been
Robert ].M. Nieminen, P.E. ; �1�5%�y�V�;.•` transmittedtotheProductApprovalAdministratorand
Florida Registration No. 59166, Florida DCA ANE1983 '�'""� co cne named d�ent
CERTIFICATION OF INDEPENDENCE:
1 Trinity�ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2 Trinity�ERD is not owned,opereted or controlled by any company manufacturing or distributing products it evaluates.
3 Robert Nieminen, P.E. does not have nor will acquire,a Flnancial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued
4 Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
�
�8
t
TRINITY I ERD
r
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code,
Residential Volume through testing in accordance with the following Standards. Compliance is subject
to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
cion Pro�ertv �tandard Year
1507.2.5, R905 2.4 Physical Properties ASTM D3462 2007
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161,Ciass F 2006
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2O07
1507.2 7 1, R905.2 6 1 Wind Resistance TAS 107 1995
3. REFERENCES:
Enti Examination Reference Date
GAF(PDM 1915) Letter of Equivalency SeaI-A-Ridge Impact Resistant IR O1/13/2012
PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004
PRI(TST 5878) ASTM D3462 GAF-080-02-01 OS/25/2005
UL(TST 1740) ASTM D3462 93NK6295 11/29/1993
UL(TST 1740) ASTM D3462 99NK43835 O1/12/2000
UL(TST 1740) TAS 107 94NK9632 03/29/2000
UL(TST 1740) ASTM D3462 O1NK06632 02/02/2001
UL(TST 1740) ASTM D3161,TAS 107 O1NK9226 05/21/2001
UL(TST 1740) ASTM D3161 O1NK37122 12/18/2001
UL(TST 1740) ASTM D3462 O1NK37122 12/19/2001
UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002
UL(TST 1740) ASTM D3161 03CA5367 03/11/2003
UL(TST 1740) ASTM D3462 03NK26444 10/17/2003
UL(TST 1740) ASTM D3462 04NK13850 06/07/2004
UL(TST 1740) ASTM D3161 04NK13850 06/23/2004
UL(TST 1740) ASTM D3161 04NK30546 03/10/2005
UL(TST 1740) ASTM D3462 04NK22009 05/06/2005
UL(TST 1740) ASTM D3161 04NK22009 OS/09/2005
UL(TST 1740) ASTM D3462 05NK27924 02/10/2006
UL(TST 1740) ASTM D3161 05NK27924 02/11/2006
UL(TST 1740) ASTM D3161, D3462 06CA18077 06/05/2006
UL(TST 1740) ASTM D3161, D3462 06CA18074 06/16/2006
UL(TST 1740) ASTM D3161, D3462 06CA35251 10/18/2006
UL(TST 1740) ASTM D3462 06CA31603 12/O1/2006
UL(TST 1740) ASTM D3161, D3462 06CA41095 12/27/2006
UL(TST 1740) ASTM D3161 07NK05228 03/13/2007
UL(TST 1740) ASTM D3161 06CA31611 04/04/2007
UL(TST 1740) ASTM D3161 06CA61148 04/09/2007
UL(TST 1740) ASTM D3161, D3462 07CA31742 11/08/2007
UL(TST 1740) ASTM D3161, D7158, D3462 08CA06100 03/13/2008
UL(TST 1740) ASTM D3161, D3462 07CA55908 04/O1/2008
UL(TST 1740) ASTM D3161, D3462 09CA10592 03/26/2009
UL(TST 1740) ASTM D3161, D3462 09CA06856 OS/15/2009
UL(TST 1740) ASTM D3161, D7158, D3462 09NK06647 08/O1/2009
UL(TST 1740) ASTM D3161, D7158, D3462 09CA27281 08/27/2009
UL(TST 1740) ASTM D3161, D7158, D3462 lOCA35554 03/OS/2010
UL(TST 1740) ASTM D3161, D7158, D3462 lOCA13686 05/15/2010
UL(TST 1740) ASTM D3462 lOCA07264 05/27/2010
UL(TST 1740) ASTM D3462 lOCA11953 10/29/2010
UL(TST 1740) ASTM D3161, D7158, D3462 lONK11951 10/30/2010
UL(TST 1740) ASTM D3161, D7158, D3462 lONK12070 11/04/2010
UL(TST 1740) ASTM D3161, D7158, D3462 08CA06100 O1/30/2010
UL(TST 1740) ASTM D3161, D7158, D3462 10CA53934 03/31/2011
UL(TST 1740) ASTM D3161, D7158, D3462 11CA48924 10/22/2011
Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R7
Certifcate of Autho�ization#9503 FL10124-R7
Revision 9:04/19/2012
Page 2 of 4
i �
f
.._^'°�'
TRINITY�ERD
UL(TST 1740) ASTM D3161, D7158, D3462 11CA47919 12/03/2011
UL(TST 1740) ASTM D3161, D7158, D3462 11CA48408 12/08/2011
UL(TST 1740) ASTM D3161, D7158, D3462 11CA48725 12/09/2011
UL, LLC. (QUA 9625) Quality Control Inspection Report, File No R21 02/06/2012
UL, LLC. (QUA 9625) Quality Control R3915 Current
4. PRODUCT DESCRIPTION:
4.1 Marquis WeatherMax, Royal Sovereign and Sentinel are a fiberglass reinforced, 3-tab asphalt
roof shingles.
4.2 Camelot, Camelot II / Camelot 30, Capstone, Country Mansion, Country Mansion II, Grand
Canyon, Grand Sequoia, Grand Slate, Grand Slate II, Monaco, Timberline American Harvest,
Timberline ArmorShield II, Timberline Natural Shadow, Timberline Natural Shadow Arctic White,
Timberline HD / Timberline Prestique 30, Timberline Prestique 40 / Timberline Cool Series,
Timberline Ultra HD/Timberline Prestique Lifetime, Timberline Majestic/Timberline Majestic 30
and Woodland are fiberglass reinforced, laminated asphalt roof shingles.
4.3 Slateline is a fiberglass reinforced, 5-tab asphalt roof shingle.
4.4 SeaI-A-Ridge, SeaI-A-Ridge Armorshield, SeaI-A-Ridge Impact Resistant IR, Ridglass 8, Ridglass
10, Ridglass 12 and Timbertex Hip and Ridge are fiberglass reinforced, hip and ridge asphalt
roof shingles.
4.5 ProStart Starter Strip Shingles and WeatherBlocker Starter Strip Shingles are a starter strips for
asphalt roof shingles.
5. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.3 Wind Classification:
5.3.1 All GAF shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are
acceptable for us in all wind zones up to Vasd = 150 mph (V„ir = 194 mph). Refer to Section 6
for installation requirements to meet this wind rating.
5.3.2 All GAF hip & ridge shingles noted herein are Classified in accordance with FBC Tables
1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for
us in all wind zones up to Vasd = 150 mph (V„it = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60
feet or less. Calculations by a qualified design professional are required for conditions outside
these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4 All products in the roof assembly shall have quality assurance audit in accordance with the
Florida Building Code and F.A.C. Rule 9N-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or
R905.2.3.
6.2 Starter Shingles:
Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R7
Certificate of Authorization#9503 FL10124-R7
Revision 9:04/19/2012
Page 3 of 4
�--. �
TRINITY!ERD
6.2.1 Installation of ProStart Starter Strip Shingles and WeatherBlocker Starter Strip Shingles shali
comply with the manufacturer's current published instructions.
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published
instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2
or R905.2, with the following exceptions:
➢ Camelot, Camelot II / Camelot 30, Grand Slate II, Country Mansion II, Monaco and
Woodland require minimum five (5) fasteners per shingle
6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than
FBC 1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of
fastening are required. Contact the shingle manufacturer for details.
6.4 Hip& Ridge Shingles:
6.4.1 Installation of Ridglass 8, Ridglass 10 and Ridglass 12 asphalt shingles shall comply with the
manufacturer's current published instructions with a minimum two (2) nails per side [total of
four (4) nails per shingle] and asphalt roofing cement.
6.4.2 Installation of SeaI-A-Ridge, SeaI-A-Ridge Armorshield and SeaI-A-Ridge Impact Resistant IR
asphalt shingles shall comply with the manufacturer's current published instructions with a
minimum two (2) nails per shingle.
6.4.3 Installation of Timbertex Hip and Ridge asphalt shingles shall comply with the manufacturer's
current published instructions with a minimum two (2) nails per shingle and beads of
Sonneborn NP1 Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant.
6.4.4 Fasteners shalf be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
7. LABELING:
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo
of the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications
detailed in FBC Table 1507.2.7.1 / R905.2.6.1.
H. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule
9N-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC — QUA9625; (847) 664-3281
- END OF EVALUATION REPORT -
E�cterior Research and Design, LLC. Evaluation Report 01506.01.08-R7
CertJfcate ofAuthorizatlon#9503 FL10124-R7
Revision 9:04/19/2012
Page 4 of 4
I Iillll IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII Illi IIII
2012145916
AFTER RECORDING-RETURN TO•
Rcpt:1457691 Rec: 10.00
DS: 0.00 IT: 0.00
08/29/12 C. Miner, Dpty Clerk
PRU�q S 0'�JEIL,Ph D PRSCO CLERK d COMPTROLLEF
PERMITNUMBER. 08OR9BK2 ���� 1PG� A,��
NOTICE OF COMMENCEMENT
The undersigned hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,
Florida Statutes,the following information is provided in this Notice of Commencement.
1. DESCRIPTION OF PROPERTY(Legal description of the property&street address,if available)TAX FOLIO NO.: �1-26-21-0010-03300-0130
susnrvrsroN CITY OF ZEPHYRHILLS sLOCx 33 �r�.acr LoT 13-16 BLDG u�vrr
CITY OF ZEPHYRHILLS PB 1 PG 54 LOTS 13-16 INCL BLOCK 33 OR 3557 PG 901
2. GENERAL DESCRIPTION OF IMPROVEMENT:
TEAR OFF EXISTING ROOF SYSTEM AND REPLACE WITH TIMBERLINE HD ROOF& FLAT ROOF SYSTEM
3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRAC7'ED FOR THE IMPROVEMENT:
a.ivamea�daadress: �REN & DANIEL BENOIT ; 38225 12TH AVENUE, ZEPHYRHILLS, FL 33542
b.Interestinproperty FEE `S�MP�-E
c.Name and address of fee simple tiUeholder(if different from Owner listed above):
a. a.coiv�rxncroR'SNAME: JASON NEUMANN / NEUMANN ROOFING, LLC
R�ont�ctor�saedress: 30427 COMMERCE DR, SAN ANTONIO, FL 33576 b.�onen�m�r� 813-782-9080
5. SURETY(ifapplicable,a copy ofthe payment bond is attached):
a.Name and address:
b.Phone number c.Amount of bond:$
6,a.LENDER'S NAME:
Lender's address: b.Phone number
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)7.,Florida Statutes:
a.Name and address:
b.Phone numbers of designated persons:
8.a.In addition to himself or herself,Owner designates of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
b.Phone number af person or entity designated by Owner
9. Expiration date of notice of commencement(the expiration date may not be before the completion of construction and final
payment to the contractor,but will be 1 year from the date of recording unless a different date is specified): ,20
WARNING TO OWNER• ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIItATION OF TF�NOTICE OF COMMENCEMENT
ARE CONS�ERED IMPROPER PAYMENTS UNDER CHAPTER 713 PART I SECTTON 713 13 FLORIDA STA Ti'RS AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YO PROPERTY A NOTTC OF COMMENCEMENT ST BE
RECORDED AND POSTED ON TI-IE JOB S1TE BEFORE TE�FIRST INSPE TION. IF YO INTEND TO OBTAIN FINAN ING.CONSULT
WTTH YOUR LENDER OR AN ATTORNEY BEFORE COMIVIEr1CING WORK OR RECORDING YO NOTICE OF COMNIINCEMENT.
Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to
the best of my knowledge a d belief.
_ � /-
__��f Jlr ��/1/�l)! T
(Si ture of wner or Lessee,or O�� er's or Lessee's �Print Name and Provide Signatory's Title/Oftice)
A orized Officer/Director/Partner/Manager)
State of FLORIDA
County of PASCO
The foregoing instrument was aclrnowledged before me this �� day of �1�(9 jJS �,2010'�
bY /l l�}/Q�/1�' �'/✓�D / T ,as �lt��'✓�/��
(n e of person) (type of authority,...e.g.officer,trustee,attorney in fact)
£or t�l4JQ�l1/' �/Vp! T
(name of pariy on behalf of whom instrument was executed)
Personally Known or Produced Identification Y Type of Ide�ification Produced �/�DJ�)�� �JJQ`�,�/� 1/Li ,
� �Jr3�"�/ 7��"�/J�f'�
TERE$A K.EWINCrCFI0M1
fNt77At2Y PUBLIC (Signature of Notary Public)
Rev IOA1-ll(S.Recordi ,,,�'�+
8•rp'f�E pF p�pR�pq (Print,Typ�,or��am�Commissioned Name of Notary Public)
, Cbmr1;�EBOa037'0
�xpinrN�1�0/2Q16 '
� ��R�+` �-�A�'�OF FLORIDA,COUNTY OF PASCO
�J • ;�' THIS IS TO CERTIFY THAT THE FOREGOING IS A
�r � • � TRUE AND CORRECT CORY OF THE DOCUMENT
' ON FILE OR OF PUBLIC RECORD IN THIS OFFICE
� • '� �,�� � ♦c d�ITNESS MY HAND D OFFICIAL SEAL THIS
i�Go�we �-��+ ' ��'� DAY OF S� 2 L�`�---
� '� • * PAULA S O'N IL,CL &G�MPTROLLER
* .-�:�G �J
� 1$$�� �e B� � �. DE�U�F'1�L��k�
'� �r�;��F c�► .