HomeMy WebLinkAbout12-13422 CITY OF ZEPHYRHILLS 5335-8TH STREET . , (si3)�so-oo20 13422 BUILDING PERMIT Permit Number: 13422 Address: 6701 BASSWOOD CIR Permit Type: MECHANICAL ZEPHYRHILLS, FL. Class of Work: A/C CHANGEOUT Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: DRIFTWOOD Est. Value: Parcel Number: 02-26-21-0210-00000-1510 Improv. Cost: 3,600.00 Date issued: 9/06/2012 Name: RENNER, DONALD &ANNA Total Fees: 55.00 Address: 6701 BASSWOOD CIR Amount Paid: 55.00 ZEPHYRHILLS, FL. 33542 Date Paid: 9/06/2012 Phone: (813)719-8982 Work Desc: A/C CHANGE OUT FRIGIDAIR SPLIT SYSTEM 3TON . /���1.�'� � DUCTS INSU D��� FINAL��✓ _("I'► � REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80(2)(c)when extra inspection trips are necessary due to any one of the following reasons: a)wrong address b)condemned work resulting from faulty oonstruction c) repairs or corrections not made when inspections called d)work not ready for inspection when called e) permit not posted on job site� plans not at job site g)work not acaessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to reoord a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financ�ng,consult with your lender or an attorney before recording your notioe of oommencement." Complete Plans,Specifications Must A pany Application.All work shall be pertormed in accordance with .�`"� Ci d rdinances. NO OCCUPANCY BEFO C.O. � ONT TOR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER s�3-�ao-oozo City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received � _ �,_.,�, � Phone Contact for Permittin �/ Owner's Name aN Owner Phone Number ��3 7 � �� Owner's Address �7o Owner Phone Number � Fee 5imple Titleholder Name �— Owner Phone Number —� Fee Simple Titleholder Address JOB ADDRESS lQ �! � LOT# � SUBDIVISION . PARCEL ID# �" � �� – —��� (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT � SIGN Q Q DEMOLISH B INSTALL 8 REPAIR PROPOSED USE Q SFR Q COMM [� OTHER TYPE OF CONSTRUCTION Q BLOCK Q FRAME �� STEEL Q DESCRIPTION OF WORK .�, BUILDING SIZE � SQ FOOTAGE HEIGHT [�BUILDING $ VALUATION OF TOTAL CONSTRUCTION DELECTRICAL $ AMP SERVICE � PROGRESS ENERGY Q W.R.E.C. �PLUMBING $ �MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION f�- /� �2.2 l [�]GAS Q ROOFING Q SPECIALTY � OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA QYES NO BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address ' License# � � ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address License# � PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address License# MECHANICAL COMPANY �/�I SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y 1 N FEE CURRE� Y/N Address License# �— RESIDENTIAL Attach(2)Plot Plans;(2)sets of Buflding Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onslte,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work PeRnit for subdivisions/large projects COMMERCIAL Attach(3)complete sets of Building Plans plus a Llfe Safery Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities 8 1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. '""`PROPERTY SURVEY required for all NEW construction. 1'111�i111111r�11 rr'1111 Dlrections. �+ <<+� rr Fill out application completely. Owner 8 Contractor sign back of application,notarized If over;2500,a Notice of Commencement is required. (A/C upgrades over 57500) *' Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from ovmer authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs if shingles Sewers Service Upgrades A/C Fences(PlobSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRlCTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictiVe than County regulations. The undersigned assumes responsibility for compli�nce wi#h any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as requi�ed by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transpo�tation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a.certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florlda Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "F.larida Construction� Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that t have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland �4reas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health � Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditio�ting, gas, or other installations not s,pecifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the\job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR I ROVEMENTS TO YOUR PROPERTY. IF YOU INT�N TO OBTAIN FINANC G, CONSULT WITH YOUR LEN AN ATTOR EFORE RECORDING YOU OT E OF COMME MT. FLORIDA JURAT(F . 117. '' ��.l OWNER OR AGE . ��'P�—��" /�__ CONTRACTOR d=-�'���� ����� Subsc�ibe�i and sworfi'4o(or affi )before me this S bs ribed and sworn to(or affi ed)before me this �j'_(o -/Z by '�'��'" bY Who is/are pe�Snnaly�-kaouun to me or has/have produced Who is/are pe�onativ known to me or haslhave produced as identlfication. as identification. Public z'�` � � Notary Public r�.ti'�"'�. ..•.:��:�; JA LINE BOGES Co issio :: :►°- � � � #EE 040520 Ciqr(imissi _ � • �� �'f gadedllxuTmyFalnlnsuranw80P3&47079 _•'•.;�•y,�; Expires December 12,2014 -,�r;:��° Name of Notary pe ,pnn e or s amped Name of No ���� ����� Envirohmental Contractors September 06, 20�2 10221 Hwy 301 Dade City FI. 33525 Summary: SYSTEM C/O license#CAC 1814275 - ER 0013583 (352)567-5515 (813)7$3-2552 www.envcontractors.com Reference#: 12589-106 Tech: CAREY Bi�� Job Name: Donald 8�Anna Renner ponald&Anna Renner 6701 Basswood Cir. 6701 Basswood Cir. Zephyrhills, FL 33542-6612 Zephyrhills, FL 33542-6612 (813)779-8982 (813)361-9615 M/MR Job Tel (813)779-8982 Desceiption of Work 9/4-CAE quoted$3600 -instail: 3 Ton FRIGIDAIRE Split System, Heat Pump, 13 SEER, 5 KW Heat Strip ++�/ARRANTY: 5 yr Parts, 5 yr Compressor, 5 yr Quality Piedge(unless Registered-THEN 10 YRS), 1 yr Iabor++PLEASE READ WARRANTY 8�COMPLETE REGISTRATION FORM 8 MAIL(to: Nordyne Inc.,ATTN: Warranty Dept., 8�0 Phoenix Pkwy., O'Fallon, MO 63368-3827)OR REGISTER ON LINE WITHIN 60 DAYS ! ! WE HAVE REGISTERED YOUR SYSTEM FOR YOU-CONFIRMATION IS ENCIOSED++ Installed Equipment Install Date Model# Seriai# Warranty Exp HEII HP COND CH5536UKA2 L940265187 HEIL A/H, 5 kw NBH3036SKC2 L940313287 * FILTER: 24X24++REF: JILL DONLIN++A/H=PLTFRM/GARAGE++ * * DRIFTWOOD++ * All material is guaranteed to be as speCified. Ali woric to be completed in a professional manner axordi�g to standarci pradices. Any aReration or deviation from above specifications involving extra costs wi11 be executed only upon written ordeB and will become an extra charge over and above the estimate. All agreemerrts Contingent upon delays beyond our control. Purchaser agrees to pay all costs of coNec�ipn,including attomey's fees. . ,a f�,�. •K . :�.,,tis; L,,.'. . .� ��, . .: Duct Seai Affidavit �t1��lrn�Nr�-� Company /Qi��_ License# �� �g � ���� Adaress Fermit# � 3'�p?p�, �7D� ��r15� � -� ��u�(�L,L3' 1�'�- 33.���. � � ffiant, hereby affirm that i am the duly licensed coMractor of record for ihe above reference permit,that aU of the forgoing information is t�ue and accurate,and that the dud sealing at the above referenced address has been completed in accordance with all applicable codes and standards. Contractors Name(printed) , Date d� '' 06 " /� Signature � ■ , Certificate of Product Ratin s AHRI Certified Reference Number: 5059842 Date: 9/6/2012 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Sourae Outdoor Unit Model Number: FT4BD-036K Indoor Unit Modei Number: B6BMM036K-B Manufacturer: FRIGIDAIRE Trade/Brand name: FRIGIDAIRE FT4BD SERIES Manufacturer responsible for the rating of this system combination Is FRIGIDAIRE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRl�ponsored, independent,third party testing: Cooling Capacity(Btuh): 34gpp EER Rating(Cooling): 11.00 SEER Rating(Cooling): 13.00 Heating Capaciry(Btuh)(a�47 F: 36800 Region IV HSPF Rating(Heating): 8.00 Heating Capacity(Btuh)� 17 F: 22000 'Ralinps followed by an asterisk(7 indi�te a wMndry nt�te of Previously publisF�ed data.uMess accanpenied w�h a WAS.which indicates en invdurNary rerate. ascwMeR a��1(�)��c.��.�o�urs c.�urtcaas a�a m�oes no�an.�uom.w.�r.�uss or g�,nsnb�s aa�u,.�a ass��o�spo�ly�r, unwtl�o�d alb�allon cf d�isbod on tlds CeMHfeab.CertlNsd��y��of any Idnd�rbip out of U�e uee w pKfornpnce of U�e product�sti orUie ratlngs are vaid ody ior modds and earflguratlons isEed In the�actiory eR www ahridirectory.org. TERMS AND CONdT10NS iftls C�rtlBcal��d Ms cnnEr��e P►oPNM'+�Y producfs ofAHRI.TMs CaitlNcaEs sIW any bs used for hidlvidwl,P�I arW conNds�NW ro�p�q�a�, xO^°°�^�'���LN�,sxospt 1brlhe�����;�P�d;�Sami�ed;en0ersd k�EO a eomPuEer d�fabs�e;or otl�arvMse uf�Imed,in any �P�a�and caMldrnWl reR�ronce. CERTIFICATE VERIFICATION � ��, Tha Y�Fonmtlon for Me oadN ciEed on tlAs eartlflq0e pn bs vwifled at www.ahridirectory.o►9, e�dc m"Verify Certificate"�Mt and e,�er u,s�c�,���„��„���� Air-Conditioning,Heating, '"�'tl1°�°°°`q'�s+�.a.wn�en ts�.a abov�and u�.can�ues No.,wn�d,ts rsaa ba� A� ��`' and Refrigeration Institute �2012 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: �2ss�aosasa�os�oos PAUL WELCH INC. MECHANICAL ELECTRICAL CIVIL ENGINEERING 1 984 S.W. BILTMORE ST. SUITE#1 1 4 PORT SAINT Luci�, FL 34984 PHONE (772) 785 - 9B88 Fax (772) 785-9933 APRIL 2O, 2O1 2 RE, RHEEM / RULJD DESIGNSTAR LOAD CALCULATIDN - SOFTWARE PROGRAM TO WHOM IT MAY CONCERN: .e PLEASE BE ADVISED THAT WE HAVE REVIEWED THE RHEEM/RUUD DESIGNSTAR LOAD CALCULATION SOFTWARE T❑ DETERMINE IF IT COMPLIES WITH THE LATEST ADOPTED BUILDING ENERGY C❑DES AND CONFDRMS TO ACCEPTED ENGINEERING DESIC�N PRACTICE. ❑UR REVIEW DEMDNSTRATED THAT THE RHEEM/RULJD DESIGNSTAR LOAD . CALCULATICIN SO�f"WARE COMPUTES BU(LDING HEATING AND C�OLING , L�ADS AND SIZES EQUIPMENT IN A MANNER CONSISTENT WITH G�OD ENGINEERING PRACTICE AND APPROVED HEATIN� AND CO�LING LOAD � CALCULATION M�TH❑DOLOGIES. IT IS 1N OUR OPINION THAT THE DESIGNSTAR SOFTWARE FLJLLY COMPLIES WITH FL�RIDA BUILDING CODE • 201 O ENERGY CONSERVATION CODES SECTIONS 403.6 hiEATING AND CQOLING EQUIPMENT AND 1 ❑ 1 .4.7. 1 .2 REPLACEMENT EQUIPMENT SIZING. THANK YOU �OR YOLJR ATTENTION TO THIS MATTER. SUBMIT'T'�D BY: _ � " . .�.�+ PALFL WELCH P.E. , FL RE� Na, 29945 PW:PP � ( � � � Desi� nStar Load �alculation Results are intended for use with Rheem heatin and molin g g systems only rr�e Mo�x tA�r�e o�c�m+on'L � � • � • "'�`��:, - �=, " LOCc""�'�rn: , - , , , Street A�ddress 6701 basswoad cir, PASCO, FL 3354� Lati tud e, Lony�tud e 27.9��►1°r -82.5 82° _M~�. .M�.�.�wµ�..�..__.___..._...__�.�. House Sq�aare Fvotage: 1700 sq. ft. —__...�....�__.__.�_....._._._._.____.____. Name: Donald Renner Phane: 813-779-8982 --.______._..__.___..___..______._._.___ Em a i I: .,.�._.____.....�,_._...._...._..,_._._.__.__.�_..._.__._ • ' � . • SH R .75 ....�___.._._._._.W_. .._.._.__. ........ ...._._. ._..._._... Number af residents 4 ._.._....__._._. ._ ......_. ._._. ._. ._..._._._. .. Ceiling height g ..........._..._.._. ._. _. _. ._. ...._...... _._. ._.._ Wall U-value � R-v�lue p.pg f 12 Floor U-value � R-value -__.-a.2 i. 5._.._. _. ._ ._._. .. _. ._._.._. .___._._. ._. .. _.._.._. ._.._.._ Ceiling U-value � R-value p,p� t �g . _._._._.... .. - Window U-value 0.5 Window SHGF .---p.g5 - Moisture grains a.g5 Duct lass % __1� ... ..._. _. .� Duct gain % l� Coo(ing infiltraction (ACH) .� 4.�; � Heating infiltration (ACH) p.g Winter ventilation p 5ummer ventilation � � - i • • s Outdoor Heating �ooling D ry b u I b t°F) 40 ._ �� .-. .__.._....._. . Daily range - M - Relative humidity .V .�.Y ._ 50% Moisture difference .^. ^ �. 5� ^ ^. . Indoor Heatin Coolin .. ..... __ ._. 9 9 _. .._._._._._._. ._. ..._._._._. ._. ..__.._. ._.._. indoor temperature (°F) 7p 75 Design temperature difference(°F) 30 16 ' � • # • � Area Btuh % of load Wall 2487 10.5 Floor 6426 27.1 Ceiling 2703 11.4 Windaws 3645 15.4 lnfiltration 6261 25.4 System Efficiency Loss 2152 9.1 Tota!: 23674 __ _._...... ._..... ._. ._.._. ._._._...... ,-- ------ ------ -- Heating Loads :'3.fi74 BTUthr Ij . �System Efficiency Loss a,. Floor �... � ,'g,� �Wall I :a. i i Ceiling � I Infiltration J `Windows � • • • • . • Ar'+ea Btuh °fo of load Wall Z326 3.5 � �ei t i ng 1��42 3�� Windows 21Q3�i 54.8 ' � __�.._..�_____....�... -�.�-.�,.- . �._.�.,.�.._..�._._ —� , . � `r ,��...� - ��'t'iSI�lle !i`r�p���r�t'� . . ',�;,�$"' ���6:�`J 4% : ,; � .i =. . _m_..._.w___.__.._.._.._.____._w�..:::'�..�,._....._...M..�.._.�......__.w..._ _w._....____�..___. ;;p,�"-{ .�;$;,,g ; , Latent infiltration 5418 14.1 ` '`6E , �,: �:, . �; ��`;��3:����� . � �. ,, ��:.���;, °� ��_ ,.,m.�,,, , •:,_ ,� . ; .,:.��.,;.;� !�.,,., M �. —.�.��m -"" ;.�,_ ,��_ ;F.�� �._ � 'q`°....�^�, ^� :;�..{,��, r r:�,�� ,��. �»:s. ,. ;� � '��'�'1�1 L � ` � - .ro.. . ,_'�Y°' ` �:�.� �.� +; . r . ,� A" � � F-a ' .. + , ;- «.,.........«...«.«....,�........n......w.za:....� ... .� ''+#4.� r e`�o.. .., s �;YJ"� . r •, "i '�;S`� �,=S,r - 'Ly,"i'� ; „ r� r �� w. a ' :"��i;a� 'r�7._:.a�;::::.�.....�M.».« �i•q��_f'�;�4y �.a 3..I�x=�'� ` Y . " '' . � �, �3* �."n�:" • '=._� � " .�,,.'�� 4 ����.;��`'a« i nternal 1907 `�'��� _ '�`� �.:. �� , � y `�:`� ;. � ' . � ,.E;�:�Y�� �:� �'a.y _ , �''�',�' _ � �,. '�" , a, -'^.,._._.'."'.'. :. ,�s_, �� "�, s ' ��, _ , .. :�„�":.� .� �' �.<�"�€���_;�s �."���� ��..�' �.:�8•..= �, `�,�,b � � ,.:. M �•�€..;. "'x „_ �; < .,-r�.'��4�:;T.'�'"' ,�,,p� y-.s-•4,y.f �Il'St��+� .�: d,�: r� . �'.;-,-c ; X.y' , : , �., ,, v�+.:"�1V 'f'd . . ,�.. . , �•.Y' � ' .s,.> r,��G$ '{.f�' i4 i 5'.ri.'Ny„,�� ue� -9 ..........«...........................ma......mry(:.�,......."�a��,...G..,................�......, .�.,e,� �s�",f.�i."_ - °l;'�,�%^���ats `,� j' �h •}�i�,re 'T � ' . ' .•.'`" ��e..'s,r..�t.r.::.�w..»........r.» ,«z$�- " . r��r: : �'�. Latent Peopte Lflad �82 2 ' .. � � �����,4 =. �:' . z _t T��t�' t: �Q�!�: ^ , . �E't1S1�}�E.' ExJB#� ��"L�.�`�} Latent (aad fi2pp SH R p,g4 Capacity at .75 SHR 3.57 Tons Cool i ng Loads 3s,3�o aTU�r�� �Sensible People Load �Latent People Load r--Wall /----Ceiling ;�. /�Internal /--Sensible Infiltratioi �s Windows --"`— '"—System Efficienc+ `Latent Infiltration � i � � ' • i ' � • ; AED Graph i 40000 I I 30000 � I' 'a p ?OOOG J 10000 �..... 0 j 8am 9am l0am llam 12pm lpm 2pm 3pm 4pm Spm 6pm 7pm 8pm Hourly Loads —Average � �_-- � 1 s � 5ystem eq�ipment selection will be made�siny the following Manual S derived values. Summer Outdoor gl�� Summer Wet Bulb 77°F Summer fndaor 75�F Summer Design Grains 5p�/o ..^. v - Winter �utdoor 4p°F Winter lndoa� 7�0� _._. .. . Sensible Cooling 32,17Q Btuh .. ^ ^ � Latent Cooling 6,200 Btuh . _ Required Cooling Airflow 1,462 CFM ._. ....... . 5ensible Heating 23,674 Btuh Required Heaing Airflow 307 CFM All calculations are based upon approv�ci,hvac industry standards and procedures,and comply witii all locaf, state and federal cade requiremenL�.All comp�ted results are Estimates Product provided by Energy Design Systems and Idea Tree