Loading...
HomeMy WebLinkAbout12-13574 CITY OF ZEPHYRHILLS 5335-8TH STREET (si3)�so-oo20 13574 BUILDING PERMIT Permit Number: 13574 Address: 5237 5TH ST Permit Type: MECHANICAL ZEPHYRHILLS, FL. Class of Work: A/C CHANGEOUT Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 11-26-21-0010-13100-0070 Improv. Cost: 4,100.00 Date Issued: 10/30/2012 Name: SWARTS, CHARLES & BEVERLY Total Fees: 60.00 Address: 5237 5TH ST Amount Paid: 60.00 ZEPHYHRILLS, FL. 33542 Date Paid: 10/30/2012 Phone: 582-301-6037 Work Desc: A/C CHANGE OUT 3 TON L q ;y.��„ p�;�FG «z`�, �w i � �� r � , DUCTSINSULATED FINAL���� REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80(2)(c) when extra inspection trips are necessary due to any one of the following reasons: a) wrong address b)condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d)work not ready for inspection when called e) permit not posted on job site� plans not at job site g)work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your properly. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with Ci Codes and Ordinances. NO OCCUPANCY BEFO C.O. ,�. �"C NTRA OR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER j Kinsey Cen t�al ' i Heat �Air-Conditioning, Inc. ; P.O. Box 2209 � Zephyrhilis, Florida 33539-2209 ' (813) 782-2300 cA-cosss2s `�` �1`"�a ` --- � ' r° o��weowsEO ! � , _ nooRess . , �rrr t ' � �' � � . ❑ ESTIMATE NATURE OF ❑ CASH SERVICE REQUEST ❑ CHARGE � � QUAN. PART NO. DESCRIPTION PRICE AMOUNT `• _ � . 1 ..- f� I 1 , � 1 � � � � , � . � , I ; i � � SERVICE PERFORMED , �� '' ��K � � � �crr�cu � �xv�n� j .. � � F � � - � � A chrc�e of ls%wfil be made oo all uopid 6�Looa afla 30 days,wfiich ia aa aomul pacmuge rNe a� of iBSG�ppliad w p�st due bd�ncea C.lwoma is liable for any chuses inc�ed'm collxtmg thi�biii. TAX i �I�r�qE� CASH�y��� TOTAL I i TECHNICIAN CUSTOMER'S SIGNATURE i a�3-�so-oozo f / 2��1 c� City of Zephyrhills Permit Application Fax-813-780.0021 ( � j Building Department l Date Received phone Contact for Permittfn � /� . �C � Owner's Name � �'1 �•r � 9 s /,1, p�S Owner Phone Number � �' 3d( - �G � � Owner's Address � � � � Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS LOT i� � SUBDIVISION � PARCEL iD# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR e ADD/ALT � SIGN [� Q DEMOLISH INSTALL REPAIR PROPOSED USE Q SFR Q COMM � OTHER TYPE OF CONSTRUCTION Q BLOCK Q FRAME 0 STEEL Q DESCRIPTION OF WORK � �b�- ��� , � G�.�- ��'. � BUILDING SIZE -1 SQ FOOTAGE C� HEIGHT OBUI�DING 3 VALUATION OF TOTAL CONSTRUCTION QELECTRICAL � AMP SERVICE Q PROGRESS ENERGY Q W.R.E.C. OPLUMBING � QMECHANICAL $ � � VALUATION OF MECHANICAL INSTALLATION /�c: � �GAS Q ROOFING Q SPECIALTY � OTHER FINISHED FLOOR ELEVATIONS � FLO00 20NE AREA QYES NO BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address License# �- -� EIECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address License# PLUMBER COMPANY SIGNATURE REGISTEREO Y/ N FEE CURRE� Y/N Address License# MECHANICAL ..�'"� COMPANY /^'S� �C��c r- SIGNATURE REGISTERED Y/ FEE CURRE� Y/N Address � License# l �-Z OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N Address License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-0-W Permit for new construction, Minimum ten(10)working days after submittal date. Requfred onsite,Construction Plans,Stortriwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(3)complete sets of Build(ng Plans plus a Life Safely Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities 8�1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. """PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Ovmer 8 Contractor sign back of application,notarized If over 52500,a Notice of Commencement is required. (AIC upgrades over 57500) "' Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of AppflcaUon Only) � Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoVSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: 7he undersigned understands that this permit may be subject to"deed" restrictions" which may be more �estrictive than County regulations. The undersigned assumes responsibiliry for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. if you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entiNed to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transpo�tation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "ce�t�cate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with app�icable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that 1 have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be perFormed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Envi�onmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of flll: Use of fill is not allowed in Flood Zone"V"unless express�y permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such flll will not adversely affect adjacent properties. If use of�II is found to adversely affect adjacent properties, the owne� may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditivning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the pe�mit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICENDER OR AN ATTORNEY BEFO E ECORDING OUR NOTICE OF COA'N NNAMENT.' CONSULT WITH YOUR L FLORIDA JURAT(F.S. 117.03) � � �--r CONTRACTO U OWNER OR AGEN7 Subscrf a svro (or aiftrm efore me this Subs bed and swo (o Hirmed)¢ fore me this �����b �����Z bY o fslare perso ally known to me or haslhave produced Who Is/are pe o to me or haslhave produced �— as identlfica6on. �-� as Identlficatlon. , �� ' Notary Public `',f,� Z �r"1�� Notary Public •�;"N-- JAC(lUEL�N S .....�,�.,�... Com I o ��12,2014 Com on �'"" :K ,+s :,� COmmISSlon#EE 040520 ' =;a " Expites Name of Notary � �? � Name of No atnu�r,csaoasas.re,^� � ,�5+�., j� t5,, i'.� s e.• y t. Duct Seal Affidavit Company I\�S .Q ��r� r� License# � �G� � � �C 6 Address Permit# 1� � ��y ,Sr�-� � �°S'� �� � ��, , �rr �� .���L�/ I�loNr� � !"�� N sx� ,affiant,hereby affirm that I am the duly licensed contractor of record for the above referenced permit,that all of the forgoing information is true and accurate,and that the duct sealing at the above referenced address has been completed in accordance with all applicable codes and standards. Contractors Name(printed)_ /rJ /�^�� � `-�-�-� �^�'S� Date ' r °� �( -2 Signature � � � De s i n Sta r Lo ' g ad Calculation Results are intended for use with Rheern heating and cooling systems only The New Degree Ot ComsOrt^' � � � � � '_ ���: StreetAddress 5237 5th st, Zephyrhills, FL 33542 " Latitude, Longitude 27.9961°. -82.582° House Square Footage: 1532 sq. ft. Name: Charlie Swarts Phone: 585-301-6037 Email. • ' • . • SH R 75 Number of residents 2 Ceiling height g Wall U-value � R-value 0.09 � 11 Floor U-value � R-value p.2 � 5 Ceiling U-value � R-value 0.053 � 19 Window U-value 0.5 Window SHGF 0.85 Moisture grains 56 Duct loss % 10 Duct gain % 10 Cooling infiltraction (ACH) 0.6 Heating infiltration (ACH) p.g � - � • • Outdoor Heating Cooling Dry bulb (°F) 40 91 Daily range M Relative humidity 50% Moisture difference 56 Indoor Heating Cooling Indoor temperature (°F) 70 75 Design temperature difference(°F) 30 16 ' . • • � • Area Btuh % of load Wa I I 2361 11 Floor 5790 26.9 Cei I i ng 2436 11.3 Windows 3315 15.4 Infiltration 5642 26.2 System EfFiciency Loss 1954 9.1 Tota I: 21498 Heating Loads , .����� �>r: � • �System Efficiency Loss Floor � �Wall Ceiling Infiltration� ` Windows • � • • . • _ ,�� �► �.'�� Wall 1259 3.7 Cei(ing 1�9� 3.8 Windows 19131 55.7 Sensible #�►fr�iration 2257' fi,� Latent Infiltration 4883 14.2 Sys�mi ���ier�ey <�is� ��3 8.�; Internal 1719 5 Sens'rble P�opte Laad 4�� 1.3 Latent People Load 460 1.3 Total: 34351 Sensible load 29008 Latent load 5343 SH R 0.84 Capacity at .75 SHR 3.22 Tons Cool i ng Loads • , ,� � � rSensible People Load I � Latent People Load �--'--Wall ��-- Cei�ing �—Internal �Sensible Infiltration System Efficienc� Windows —� � Latent Infiltration � � � • . � • • � � � AED Graph 30000 20000 � � 0 r 10000 0 8am 9am l0am 12am 12pm lpm 2pm 3pm 4pm Spm 6pm 7pm 8pm — Hourly Loads —Average � � � � � • System equipment selection wiil be made using the following derived values Summer Outdoor 91°F Summer Wet Bulb 77°F Summer Indoor �5�F Summer Design Grains 50% Winter Outdoor 40°F Winter Indoor �poF Sensible Cooling 29,008 Btuh Latent Cooling 5 343 Btuh , Required Cooling Airflow 1 319 CFM , Sensible Heating 21,498 Btuh Required Heaing Airflow 279 CFM All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements All computed results are Estimates Product provided by Energy Design Systems and Idea Tree