Loading...
HomeMy WebLinkAbout12-13443 CITY OF ZEPHYRHILLS 5335-8TH SIREET (si3)�so-oo20 1 3 3 FIRE SPRINKLER SYSTEM PERMIT Permit Number: 1344 133 Address: 7920 GALL BLVD Permit Type: FIRE INKLER SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE-SPRINKLER SYS Township: Range: Book: I�roposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: ZEPHYR COMMONS Est. Value: Parcel Number: 35-25-21-0130-0000-0140 Improv. Cost: 3,000.00 Date Issued: 9/21/2012 Name: SF ZEPHYR COMMONS LP Total Fees: 290.00 Address: 2851 JOHN ST STE 1 Amount Paid: 290.00 MARKHAM ON CANADA L3R 5R7 CANAD Date Paid: 9/21/2012 Phone: Work Desc: INSTALLATION FIRE SPRINKLER SYSTEM - HUMANA OFFICE FIRE INSPECTION FEES 110.00 CONTRACTOR CERTIFICATE 30.00 �,�-� �'jP� �� � �� � Z �b, � l i �� � FIRE ACCEPTANCE Final Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections,plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approvai of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO BTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN O BEFORE RECORDING YOUR NOTICE OF COMM C NT CTOR SIGNATURE PERMIT OFFICER PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041 a�3-�ao-oo2o City of Zephyrhills Fire Fax-813-780-0021 Permit Application ate Received cr Z _ Phone Contact for Permit f � Q j 3 7 nvner's Name 7, Owners Phone Number tivner's Address � G�{� �(/ ee Simple Titleholder Name Titleholder Phone Number � � � ee Simple Titleholder Address � �° - _ a� - - ,�_ _- "` ;�s°'a"` - - ' �b Address Z� C./J �Q L.L �l V � Lot# ub Divi:.;:sn Parcel# _ _ - . .._ . ., . _ _a �xa r=-r,:Nv,r.m.•e-:, „ �.?-_ ,.,-.. .: ,. -. _ - , - _ . ,'.. . ..1:..la�:4.ai... ?C'�XA.'w 37r8.Yt' .. _ k. � .-� ... � Bio-Hazard Waste Storage-ANNUAL � Fumigation Tent � Comm Exhaust Kitchen HoodlDuct � Hazardous Material(Tier II or RQ Facility)ANNUAL Controlled Bum � Hood Installation .!� � C�<< Emergency Generator<30 kw � LP/Natural Gas-Installation y{-�f � � Emergency Generator>30 kw � LPlNatural Gas-ANNUAL Sale �f' � 0 (�, Fire Protection Maintenance-ANNUAL � Places of Assembly-ANNUAL �y emi �n er Sprinkler � ❑ ❑ ❑ B � Recreational Bum Fire Alartn � ❑ ❑ ❑ � � Sparklers Hood Cleaning � ❑ O ❑ � Sprinkler System Instaflations � � �"I � ��l�s Hood Suppression � ❑ ❑ ❑ � � Standpipes(Sprinkler Sys) � �J ��� 'S�e� � � IY /S; Fire Alarm Installation Torch Roofing/Tar Kettle V � Fire Pumps � Waste Tire Storage ANNUAL � Fire Works � Flammable Application-ANNUAL Valuation of Project Fuel Tanks Q Other: "_ _ _ _ � _ L ,.-. _ _. � a!n���n `_ � -. ��. 'E3'y'N'"t:'R- '-( ," . i t.-, � - � - - ..., _ ,-- -.Y.sa�. ti.1'f`"i.'!'T^4F,. �.1 ontractor Compa�y � �,/�/•C M1.�D ` ignature � D �Q�l?[.t, Registered Y/N Fee Current ` Y/N Address Z �(a / License# LECTRICIAN Company ignature Registered Y/N Fee Current Y/N Address License# LUMBER �, • Company ignature Registered Y/N Fee Current Y/N Address License# IECHANICAL Company • ignature Registered Y/N Fee Current Y/N Address License# THER Company ignature Registered Y/IV Fee Current Y/N Address License# irections: Fill out application compietely Owner 8 Contractor sign back of appiication,nota�zed(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement is required(Mechanical work over$5000) Supply two(2)sets of drawings with applicable documentation Allow 10-14 days for review after submittal date Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com) HOTICE OF DEED RESTRICTIONS The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any appli�able deed res4rictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the� owwr�er�has hired�a�contractor or cont�actors to undertake work, they may be required to be licensed in accordance with state and lo�cal repulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdeme�nor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If yow, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitted to permitting�privileges in Pasco County. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, certify that I, the applicant, have been provided with a copy of the "Florida Const�uction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. ' If I am the AGEt�T FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technicat codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If�vyork ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEM�NT M1XY RESULT IN'YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. .IF YOU INTEND TO OBTI�N FlNANCI�iG,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR TICE F COM CEMENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACT Subscribed and swom to(or affirmed)before me this Subscribed an swom to(or f ed efore me�qis� /i �� bY �30-r '— b tJ� �_ �J ���' Who is/are personally known to me or has/have produced Wh�{slare person y known to me or has/have produced as identification. ' �R i v�-� (,cx•Sr as identification. � �) Notary Public �"e ���- Notary Public •• JACQUELINE BOG Commission No. . Com iss :.: � ,���' �i�December 12,2014 Name of Notary typed,printed or stamped Name of o ry , ZEPHYRHILLS FIRE DEPARTME[�T 6907 Dairy Road, Zephyrhills, FL 33542 FIRE SERVICE USER FEES Occupancy No.: Plan No.: Contractor: L-�L �� ����,� �r Business Name: �ri.n Billing Address: Business Address: ��` 7 0 � >41 ( � �� 8usiness Phone No.: Billing Phone No.: . Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE FALSE ALARM FEE 8 Site Plan N/C Annual N/C Sprinkler $50 1st Alarm N!C Mult�-Famiiy/Commercial .06 sf 1st Re-inspection N/C Standpipes $50 2nd Alarm N/C (Minimum Charge$25.00 2nd Re-inspection $100 Fire Pump $50 3rd Alarm N/C � Plan Revisions DBL 3rd Re-inspection $250 Hoods $50 4th Alarm $100 4th Re-Inspection $500 Fire Alarm $50 5th Alarm $150 SPRINKLER SYSTEMS (Business dosed until LP Gas $50 6th Alarm $200 0-25 Heads $50 violaHons corrected) Natural Gas $50 NON COMPLIANCE $150 ' '26 plus Heads $100 SPRINKLER SYSTEMS Fuel Tanks- �,ercaok $50 STANDPIPE SYSTEM Hydro Undergrounds $45 Sparklers $100 �Per Riser $50 ydrostatic Test $65 per system Fire Works $500 FIRE PUMP Acceptance Test $45 persystem Camp Fire $25 � Per Pump $100 Hydrant Flow $75 Controlled Bum $100 FIRE ALARM SYSTEM Hood/Duct $50 0-25 Devices $50 FIRE ALARM SYSTEM Place of Assembly a50 nrm�ai 26 plus Devices $100 8 System Acceptance $50 Fire ProtecGon S25 SUPPRESSION SYSTEMS Recall Acceptance $50 FlammableApplication $50 Annual Wet $5� OTHER Waste Tire Storage $50 Annual ��Y $50 Fire WalUSmoke Wall $15 Perwau Generator<KW $100 CO2 $50 LP Ges $25 per tank Generetor>30 KW 150 Other $50 Natural Gas $25 persystem BiaHazard Waste $100 Mnual KITCHEN EXHAUST Fumigation Tenting S50 �Hood/Ducts $50 Tent 10'x10'or greater $15 perrent Torch PoUApplied �50 OTHER Fire Pump $45 Haz.Materials $100 annuai LP Installation per tank $50 Fire Suppression $30 Fuel Tank Installation $50 System Acoeptance (Per Tank) $50 E�aust Hood/Duct $30 �Natural Gas Installation $50 Re-inspection DBL (Per System) (other than annual) �Spray Booth $50 � Inspection scheduled DBL and cancelled less than 8 24 hours ConsUuction Insp. N/C Emergency VehiGe A� $50 FALSE ALARM PLANS TOTAL� INSPECTION TOTAL (6 PERMIT TOTAL,-�� TOTAL�� /' GRI'ND TOTAL C�� Comments: ���'y.l �'� Date: C 1 Z Inspector: nin Jacqueline Boges To: Keith Williams Subject: plans in your box �.hief placed in your box plans for the humana office sprinklers contractor I &I fire protection location 7920 gall blvd. Thanks Jackie Boges Code Support Specialist e�. 35i3 /' . � (�., ` �Q 1 � / „ � � �... �/ ` 1 (���� 2,5 � 5 f��� j5�'� �-..--__. , � , �-�S� �. , 7��s7' � t= ,� pe,�r,, Ces i 1 CONCRETI N KO 0 Ia 0Q o Q = 9.1 .Qo 0Q t.4 0 HILTI SLEEVE ANCHOR OR - CONC. CEILING DROP -IN ANCHOR STRUCTURE BAR JOIST OR I -BEAM BAR JOIST OR I -BEAM BEAM CLAMP, B -LINE 83054 RO EQUAL BEAM CLAMP SPRINKLER PIPING GALVANIZED ROD WITH WASHERS AND NUTS PIPE HANGER R -LINE 83100 OR EQUAL TYPICAL PIPE MOUNTING DETAIL NO SCALE PIPE SIZES 1" THROUGH 44: ROD SIZE 318" PIPE SIZES 5" THROUGH 8 ": ROD SIZE 1/2" PIPE SIZES 10" THROUGH 12 ": ROD SIZE 5/8" EXISTING UPRIGHT SPRINKLER HEAD TO BE DEMOLISHED. EXTEND 1" EXISTING FEED LINE TO NEW SPRINKLER HEAD LOCATION (TYP) - NEW RELOCATED PENDENT SEMI - RECESSED SPRINKLER HEAD (TYP) — EXISTING FIRE RISER ROOM. REFER TO REFURBISHMENT NOTE ON THIS SHEET FOR FURTHER INFORMATION — EXISTING F.D.C. EXISTING 2" DRAIN - EXISTING FIRE RISER UPRIGHT HEAD 4" UNDER BOTTOM OF DECK FIRE PROTECTION PLAN - LEVEL 1 118" =1' -0" T. OM 0 CK: 28' EXISTI NEW LEGEND AND ABBREVIATIONS _- SP ------ -_ S2 RMN �'�='RMN EXISTING SPRINKLER PIPING TO REMAIN NEW SPRINKLER PIPING EXISTING UPRIGHT SPRINKLER HEAD TO REMAIN AS IS EXISTING PENDENT SPRINP L ER HEAD TO REMAIN AS IS EXISTING PENDENT SPRINP LER HEAD TO BE DEMOLISHED, CAPPED AND ABANDONED EXISTING SPRINKLER HEA[1 TO BE RELOCATED. EXTEND 1" EXISTING FEED LINE TO NEW SPRINKLER HEAD LOCATION. REPLACE FITTINGS AND DROP AS REQUIRED NEW SPRINKLER HEAD OF THE SAME COVERAGE, RESPONSE AND K- FACTOR AS EXISTING SPRINKLER HEAD ON NEW LOCATION. REPLACE FITTINGS AND DROP AS REQUIRED EXISTING SPRINKLER HEAD TO BE REPLACED WITH NEW SPRINKLER HEAD OF THE RPL SAME COVERAGE, RESPONSE AND K- FACTOR AS EXISTING SPRINKLER HEAD. REPLACE FITTINGS AND DROP AS REQUIRED NEW ADDED SPRINKLER HEAD OF THE SAME COVERAGE, RESPONSE AND K- FACTOR N AS EXISTING SPRINKLER HEAD. CONNECT TO CLOSEST BRANCHLIKE /CROSS MAIN. COORDINATE WITH ARCHITECT PRIOR TO PURCHASE AND INSTALLATION ® POINT OF CONNECTION TO EXISTING PIPING EXISTING UPRIGHT HEAD TO BE DEMOLISHED ( #) 6' -0" MAX. I I (U.N.0.) E 1 I L I-I 1 - L I W1 PLE. RED i HUMANAO! Project HUMANA- ZEPHYRHILLS, FLORIDA- GUIDANCE CENTER 7920 GALL BLVD. ZEPHYRHILLS, FLORIDA 33541 Prepared for HUMANA INC. Contract No: 12.01622.00 HOK One Tampa City Center, Suite 1800 Tampa, FL 33602 USA t +1813 229 0300 f +1813 223 7116 FL Reg: AAC001139 All reproduction & inteliectuoi property rights reserved 0 2012 In Association with d i I a� CONSULTING ENGINEERS! SDM Consulting Engineers MEP Engineer 135 Almeria Ave. Coral Gables, FL 33134 305.446.2788 wwo,sdmcorp.com Key Plan I�r Professional Seats CITY OF ZE =PNY6 Fit - - - - -- PLANS EXAMINER E ESTO ALCMA JOSE I. MARTINEZ P.E. 53823 P.E. 53779 ALL 1� ORK SI -TALL CO\IPLY' WITH ALL No. Issue Description YYYY -MM -DD PREV.�ILING CODES, FLORIDA BUILDIN(3)1 50% CONSTRUCTION DOCUMENTS 06.15.2012 CODE, NATIONAL ELECTRIC CODE AND 02 BID SET 06.29.2012 SEMI - -RECESSED PEND[:NT HEAD DETAIL 7EI'I1VQt4I1 LSORDINANCEs NO SCALE NOTES: 1. SPRINKLERS IN COMMON AREAS SHALL BE POSITIONED IN CENTER OF CEILING TILE BOTH WAYS. 2. SPRINKLERS IN AREAS OTHER THAN COMMON AREAS SHALL BE POSITIONED AS CLOSE TO CENTER OF CEILING TILE AS POSSIBLE. 3. COORDINATE WITH ARCHITECT FOR TYPE AND FINISH PRIOR TO PURCHASE AND INSTALLATION, O IF CEILING STRUCTURE IS OF THE CCMBUSTIBLE TYPE (I.E. WOOD TRUSSES), UPRIGHT HEADS MUST No. Revision Description YYYY -MM -DD REMAIN .installing Contractor: N.L CHECKED BY: J.C. 00 NUMBER: 2012 --1 FM I s -6 -2012 1 Z�M� ; L&L FIRE 1'ROTEC7'ION, LLC. 0 ] 12l306 NORTH BOULEVARD TAMPA, FLORIDA 33612 Drawn by SDM Reviewed by SDM Project No 12.01622.00 Sheet Tltle: LEVEL 1 FIRE PROTECTION PLAN Original drawing Is 38 x 24 Do not scale contents of this drawing Sheet Number -=--- EXISTING UPRIGHT SPRINKLER HEAD TO BE DEMOLISHED. EXTEND 1" EXISTING FEED LINE TO NEW SPRINKLER HEAD LOCATION (TYP) NEW RELOCATED PENDENT I SEMI - RECESSED SPRINKLER HEAD (TYP) I ��� EXISTING i i T. OM 0 CK: 28' EXISTI NEW LEGEND AND ABBREVIATIONS _- SP ------ -_ S2 RMN �'�='RMN EXISTING SPRINKLER PIPING TO REMAIN NEW SPRINKLER PIPING EXISTING UPRIGHT SPRINKLER HEAD TO REMAIN AS IS EXISTING PENDENT SPRINP L ER HEAD TO REMAIN AS IS EXISTING PENDENT SPRINP LER HEAD TO BE DEMOLISHED, CAPPED AND ABANDONED EXISTING SPRINKLER HEA[1 TO BE RELOCATED. EXTEND 1" EXISTING FEED LINE TO NEW SPRINKLER HEAD LOCATION. REPLACE FITTINGS AND DROP AS REQUIRED NEW SPRINKLER HEAD OF THE SAME COVERAGE, RESPONSE AND K- FACTOR AS EXISTING SPRINKLER HEAD ON NEW LOCATION. REPLACE FITTINGS AND DROP AS REQUIRED EXISTING SPRINKLER HEAD TO BE REPLACED WITH NEW SPRINKLER HEAD OF THE RPL SAME COVERAGE, RESPONSE AND K- FACTOR AS EXISTING SPRINKLER HEAD. REPLACE FITTINGS AND DROP AS REQUIRED NEW ADDED SPRINKLER HEAD OF THE SAME COVERAGE, RESPONSE AND K- FACTOR N AS EXISTING SPRINKLER HEAD. CONNECT TO CLOSEST BRANCHLIKE /CROSS MAIN. COORDINATE WITH ARCHITECT PRIOR TO PURCHASE AND INSTALLATION ® POINT OF CONNECTION TO EXISTING PIPING EXISTING UPRIGHT HEAD TO BE DEMOLISHED ( #) 6' -0" MAX. I I (U.N.0.) E 1 I L I-I 1 - L I W1 PLE. RED i HUMANAO! Project HUMANA- ZEPHYRHILLS, FLORIDA- GUIDANCE CENTER 7920 GALL BLVD. ZEPHYRHILLS, FLORIDA 33541 Prepared for HUMANA INC. Contract No: 12.01622.00 HOK One Tampa City Center, Suite 1800 Tampa, FL 33602 USA t +1813 229 0300 f +1813 223 7116 FL Reg: AAC001139 All reproduction & inteliectuoi property rights reserved 0 2012 In Association with d i I a� CONSULTING ENGINEERS! SDM Consulting Engineers MEP Engineer 135 Almeria Ave. Coral Gables, FL 33134 305.446.2788 wwo,sdmcorp.com Key Plan I�r Professional Seats CITY OF ZE =PNY6 Fit - - - - -- PLANS EXAMINER E ESTO ALCMA JOSE I. MARTINEZ P.E. 53823 P.E. 53779 ALL 1� ORK SI -TALL CO\IPLY' WITH ALL No. Issue Description YYYY -MM -DD PREV.�ILING CODES, FLORIDA BUILDIN(3)1 50% CONSTRUCTION DOCUMENTS 06.15.2012 CODE, NATIONAL ELECTRIC CODE AND 02 BID SET 06.29.2012 SEMI - -RECESSED PEND[:NT HEAD DETAIL 7EI'I1VQt4I1 LSORDINANCEs NO SCALE NOTES: 1. SPRINKLERS IN COMMON AREAS SHALL BE POSITIONED IN CENTER OF CEILING TILE BOTH WAYS. 2. SPRINKLERS IN AREAS OTHER THAN COMMON AREAS SHALL BE POSITIONED AS CLOSE TO CENTER OF CEILING TILE AS POSSIBLE. 3. COORDINATE WITH ARCHITECT FOR TYPE AND FINISH PRIOR TO PURCHASE AND INSTALLATION, O IF CEILING STRUCTURE IS OF THE CCMBUSTIBLE TYPE (I.E. WOOD TRUSSES), UPRIGHT HEADS MUST No. Revision Description YYYY -MM -DD REMAIN .installing Contractor: N.L CHECKED BY: J.C. 00 NUMBER: 2012 --1 FM I s -6 -2012 1 Z�M� ; L&L FIRE 1'ROTEC7'ION, LLC. 0 ] 12l306 NORTH BOULEVARD TAMPA, FLORIDA 33612 Drawn by SDM Reviewed by SDM Project No 12.01622.00 Sheet Tltle: LEVEL 1 FIRE PROTECTION PLAN Original drawing Is 38 x 24 Do not scale contents of this drawing Sheet Number