Loading...
HomeMy WebLinkAbout13-13961 CITY OF ZEPHYRHILLS ' , 5335-8TH STREET ` (sss)�so-oo20 13961 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL Permit#:13961 Issued: 6/10/2013 Address: 7326 GALL BLVD Permit Type: GENERAL BUILDING PERMIT ZEPHYRHILLS, FL. Class of Work: ADD/ALT COMMERCIAL Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 15,600.00 Total Fees: 172.50 Subdivision: CITY OF ZEPHYRHILLS Amount Paid: 172.50 Date Paid: 6/10/2013 Parcel Number: 35-25-21-0010-08800-0000 Name: JURIN ROOFING SERVICES INC Name: TOWNVIEW RETAIL LLC Addr: 2150 ROSEDALE RD Address: 725 CONSHOHOCKEN STATE RD QUAKERTOWN, PA 18951 BALA CYNWYD PA 190042102 Phone: (215)536-1886 Lic: Phone: (610)667-5800 Work Desc: REPAIR/REROOF PENTHOUSE AFTER REMOVAL PDT#FL14083-R3 r ) �c- . . 2-� __ � 3 � FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPEC7ION FEES: Reinspection fees will comply with Florida Statute 553.80(2)(c)when extra inspection trips are necessary due to any one of the following reasons: a)wrong address b)condemned work resulting from faulty construction c) repairs or corrections not made when inspections called d)work not ready for inspection when called e) permit not posted on job site� plans not at job site g)work not accessible. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to reaord a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application. All work shall be pertormed in accordance with Ci Codes and Ordinances. NO OCCUPANCY BEFORE C.O. � � � CONT RS SIGNATU E PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 , ' Building Departrnent Date Received _Sf_ 3 phone Contact for Permitting 215 529 _ 4151 � � � � � � � � � � � � � Owner's Name Townview Retail L�C Go Stoltz RE Partner LLC pyrner Phone Number 610-667-5800 Owner's Address 725 Conshohocken State Road,Bala Cynwyd,PA 19004 pWner Phone Number Fee Simpls Tttleholder Name Townview Retail LLC c/o Stdtz RE Partner LLC Owner Phone Number Fee Simple Titleholder Address 725 Conshohocken State Road, Bala Cynwyd, PA 19004 JOB ADDRE3S 7326 Gall Blvd., Zephyrhills, FL 33541 (Townview Square-TJ Maxx) LOT# �� SUBDIVISION �— —� PARCEL ID# 35-25-21-0010-08800-0000 �OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR 8 ADD/ALT � SIGN � � DEMOLISH INSTALL REPAIR PROPOSED USE Q SFR � COMM � OTHER TYPE OF CONSTRUCTION Q BLOCK Q FRAME Q STEEL Q DESCRIPTION OF WORK Roof repair after penthouse removal (see attached scope of work) BUILDING SIZE N�A SQ FOOTAGE N�A HEIGHT N�A �BUIIDING $ 15,GOO.00 VALUATION OF TOTAL CONSTRUCTION OELECTRICAL $ AMP SERVICE Q PROGRESS ENERGY Q W.R.E.0 �PLUMBING $ QMECHANICAL $ VALUATION OF MECHANICAL INSTALLATION �-�1 ( � �" � 1' �GAS � ROOFING Q SPECIALTY � OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE Af2EA �YES NO '� . . . . . . . BUILDER '��� COMPANY �urin Roofing Services, Inc. SIGNATURE REGISTERED Y! N �E CuRRen Y!N nddress 29716 Highway 27, Dundee, FL 33838 �icense# CCC1325665 ELECTRICIAN � COMPANY SIGNATURE REGISTERED Y/ N FEE CURREt� Y/N Address License# �— PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREA Y/N Address License# �— MECHANICA� COMPANY SIGNATURE ___� REGISTEREp Y/ N FEE CURRE� Y/N Address License# � � OTHER COMPANY SIGNATURE REGIS7ERED Y/ N FEE WRRE� Y/N Address License# IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIItllllllllll RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(i0)worlcing days after submittal date. Required onsite,Construction Plans,Stormwater Plans w!Silt Fence installed, Sanitary Facilities 8 1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Fortns.R-O-W Permit for new construction. Minimum ten{10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities 8 1 dumpster Site Work Pertnit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. *"'PROPERTY SURVEY required for all NEW construction. Directions.• Fill out applicadon completely Owner 8 Contractor sign back of application,notarized If over 52500,a Notice of Commenceme�t is required. (NC upgredes over 57500) " Agent(for the cwit�actor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (Front of Application Only) Reroofs ff shingles Sewers Service Upgrades AJC Fences(PIoUSurveylFootage) Drlveways-Not over Cou�ter if on public roadways..needs ROW NOTICE.OF DEED RESTRICTIONS� The undersigned understands that this permit may be subject to"deed" restrictions" ' w,hich may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this appfication for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT• I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill - Use of fill is not allowed in Flood Zone"V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FL(�RIDA JURAT(F.S. 117 03) OWNER OR AGENT CONTRACTOR �urin Roofing Services, Inc. Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmedl before me this bY 4th day of March, 2013 by Eric W.Jurin Who islare personally known to me or has/have produced Who is/are personally known to me or has/have produced as identification. as identification. / Notary Public Notary Public Commission No. Commission No. 1218006 Laura M Wertman Name of Notary typed,printed or stamped Name of Notary typed,prirL,t���,m��NNSYLVANIA NOTARUL SEAL LAURA M.WERTMAN,Nota�y Public Qus�tertown Boro.,Bucks County Comrtaasion E ' A st 31,2013 . ,�``��' ��� �� -��- � .�. I City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: ��`� �� ��` ����'('- Date Received: 3�"���3 Site: � _� �' �/4 /� ��� �� _ Permit TYpe: ����?L�i t� ����r ��2e r�n'tcL�� Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ i � _ � �?���� � �� � � �- � C�l '1�(. I�� �'*�J�' �' l.rcn!°P , ' � ;✓�-�C l tii,� ,�i��� � , �,� r�>;����' ���� ��� � 1 �<< � � c.��2v�!`�-�G� � r� �n��c�/� ���, ��, L ����;� 'cC � 3 .�,-� 3 This comment sheet shall be kept with the permit and/or plans. �'� � Kalvin witzer— s Examiner Date Contractor and/or Homeowner (Required when comments are present) Corporate Office and Remittance: +. 2150 Rosedale Road, Quakertown, PA 18951 PA Contr #PA019043 Florida Branch Office: 29716 US Highway 27, Dundee, FL 33838 Florida Contr. #CCC1325665 FL Business Lic. #23289 Jurin Roofing Services, Inc. Tel.(800)710-7525 Fax(215)536-2661 www.jurinroofing.com Proaosal - Reaairs Stoltz Management Date: 03/04/2013 725 Conshohocken State Road Bala Cynwyd, PA 19004 Buildinq: Townview Center—TJ MAXX 7246 Gall Blvd. Zephyrhills, FL 33541 Job: PRJ#2290: Townview Center- TJ MAXX—Penthouse Removal Price: Demolition............. $14,400 Roof Repair........... $15,600 TOTAL................. $30,000 Work To Be Performed: Removal of Penthouses from Roof Surface 1. Mobilization 1.1 Setup site to meet OSHA fall protection requirements. This will include setup of various items including enclosed trash chute, warning lines, and guard rails at load and discharge points. All safety equipment being setup on site is for the sole use of Jurin Roofing Services, Inc. and is not intended for use by others. Jurin Roofing Services, Inc. is not responsible for the safe conduct or safety of other personnel on site. 1.2 Load all materials onto roof surface via crane or boom lift. Jurin Roofing Services, Inc. will make maximum efforts to limit the storage of materials and equipment on the ground during the construction proj ect. 1.3 Provide temporary toilet facilities for the duration of the project. 1.4 Prior to the commencement of the project, Jurin Roofing Services, Inc. requests a pre-construction meeting between the owner's representative and the Jurin Roofing Services, Inc.'s project manager to discuss all project details prior to start. 1.5 Any disconnection/reconnection of existing roof top mounted equipment or equipment mounted directly to the underside of the roof deck is the responsibility of the building owner and is not included in this scope of work. Owner agrees to have an electrician or other contractor certify that all power and other feeds into these penthouses has been properly disconnected and that all lock-out/tag-out requirements are met. Owner agrees to hold harmless and indemnify Jurin Roofing Services, Inc. free of all liabilities as the result of the building owner's or manager's failure to disconnect equipment when requested by Jurin Roofing Services, Inc. Jurin Roofing Services, Inc. must provide 24 hours notice of disconnect/reconnect requirements when possible. PRJ#2290: Townview Center-TJ MAXX—Penthouse Removal Page 1 of 5 Corporate Office and Remittance: M � 2150 Rosedale Road, Quakertown, PA 18951 PA Contr.#PA019043 Florida Branch Office: 29716 US Highway 27, Dundee, FL 33838 Florida Contr #CCC1325665 FL Business Lic. #23289 Jurin Roofing Services, Inc. Tel. (800)710-7525 Fax(215)536-2661 www.jurinroofing.com 2. Demolition 2.1 After confirmation that all electrical and other feeds into the penthouses have been disconnected our team will remove all equipment from the interior of the penthouses. This includes piping, conduit, lighting, and all other equipment mounted to the interior of the penthouses. 2.2 All exterior metal siding and roofing material will be removed from the structure. 2.3 The penthouse frame will be removed. 3. Framing 3.1 Install new wood blocking as a horizontal ledger around the perimeter of the penthouse on the concrete wall which is currently in place. 3.2 Install new wood framing into opening to support decking. 3.5 Install .5" plywood decking over the framing members. 5. Roof Installation 5.1 Install fully adhered .045 white TPO roof inembrane. 5.2 Perimeter edge of roof inembrane will be fully terminated with application of aluminum termination bar. 6. Contract Provisions and Exclusions 6.1 Asbestos, lead based paint, and toxic materials exclusion - This proposal and contract is based upon the work to be performed by Jurin Roofing Services, Inc. not involving contact with asbestos-containing, lead based, or toxic materials and that such materials will not be encountered or disturbed during the course of performing the re-roofing work. Jurin Roofing Services, Inc. is not responsible for expenses, claims or damages arising out of the presence, disturbance or removal of asbestos- containing, lead based, or toxic materials. In the event such materials are encountered, Owner will make arrangements with others for the handling and/or removal of such materials and/or Jurin Roofing Services, Inc. shall be entitled to additional time and compensation for additional expenses incurred as a result of the presence of asbestos, asbestos-containing, lead based, or toxic materials at the work site. 6.2 Change Orders - If Jurin Roofing Services, Inc. is requested by general contractor, prime contractor or owner to perform extra or changed work that was not part of Jurin Roofing Services, Inc.'s original scope of work, general contractor, prime contractor or owner will provide reasonable compensation to Jurin Roofing Services, Inc. for said work. General contractor, prime contractor or owner shall not give orders to Jurin Roofing Services, Inc. for the work that is required to be performed at that time and then refuse to make payment on the grounds that a Change Order was not executed at the time the work was performed or the general contractor, prime contractor or owner's representative was not authorized to order the change. General contractor, prime contractor, owner and Jurin Roofing Services, Inc. recognize that in order for construction projects to proceed in a timely and efficient manner, changes in the original specifications frequently are made prior to execution of formal Change Order documents. The parties agree to work in good faith with each other so that Jurin Roofing Services, Inc. does not proceed with changed work without authorization and Jurin Roofing Services, Inc. receives fair compensation for authorized change work. PRJ#2290: Townview Center-TJ MAXX—Penthouse Removal Page 2 of 5 Corporate Office and Remittance: :�! � 2150 Rosedale Road, Quakertown, PA 18951 PA Contr.#PA019043 Florida Branch Office: 29716 US Highway 27, Dundee, FL 33838 Florida Contr #CCC1325665 FL Business Lic. #23289 Jurin Roofing Services, Inc. Tel. (800)710-7525 Fax(215)536-2661 www.jurinroofing.com 6. Contract Provisions and Exclusions (con�) 6.3 Dispute Resolution - In the event of a dispute between the parties hereto, the parties shall seek to mediate the dispute. If inediation is not successful, arbitration shall be promptly conducted. Both mediation and arbitration shall be held in the county where the Project is located. 6.4 Electrical Conduit- Owner represents there is no electrical conduit embedded within the existing roofing to be removed or attached directly to the underside or topside of the roof deck upon which contractor will be installing the new roof. Owner will indemnify Jurin Roofing Services, Inc. from any personal injury, damage, claim or expense because of the presence of electrical conduit, shall render the conduit harmless so as to avoid injury to Jurin Roofing Services, Inc. personnel, and shall compensate Jurin Roofing Services Inc. for additional time and expense resulting from the presence of such materials. 6.5 Fumes and Emissions - Customer acknowledges that roofing involves the use of solvent based materials. Odors and emissions from roofing products will be released and noise will be generated as part of the roofing operations to be performed by Jurin Roofing Services, Inc. Customer shall be responsible for interior air quality, including controlling mechanical equipment, HVAC units, intake vents, wall vents, windows, doors and other openings to prevent fumes and odors from entering the building. Customer is aware that roofing products emit fumes, vapors and odors during application process. Customer shall indemnify and hold harmless Jurin Roofing Services, Inc. from claims from third parties relating to fumes and odors that are emitted during the normal roofing process. 6.6 Indemnify and Hold Harmless Clause - Jurin Roofing Services, Inc. agrees to indemnify and hold harmless the Owner from all claims, damages, losses and expenses for personal injury, including death and property damage, to the extent caused by a negligent act or omission by Jurin Roofing Services, Inc. or someone for whose acts Jurin Roofing Services, Inc. is responsible. Jurin Roofing Services, Inc. is not obligated to provide indemnity for damages, losses, claims or expenses to the extent due to the negligence or fault of indemnities ar others for whose conduct Jurin Roofing Services, Inc. is not responsible. Similarly, Owner shall indemnify and hold harmless Jurin Roofing Services, Inc. from all claims for bodily injury, including death or other damages, to the extent due to the negligence of Owner or the fault of its agents, representatives or employees. Owner agrees to hold harmless and indemnify Jurin Roofing Services, Inc. from any and all future construction defect claims. , 6.7 Mold growth exclusion - Jurin Roofing Services, Inc. and Owner are committed to acting promptly so that roof leaks are not a source of potential interior mold growth. Owner will make periodic inspections for signs of water intrusion and act promptly, including notice to Jurin Roofing Services, Inc., if Owner believes there are roof leaks, to correct the condition. Upon receiving notice Jurin Roofing Services, Inc. will make repairs promptly so that water entry through the roofing installed by Jurin Roofing Services, Inc. is not a source of moisture. Jurin Roofing Services, Inc. is not responsible for indoor air quality. Owner shall hold harmless and indemnify Jurin Roofing Services, Inc. from claims due to poor indoor air quality and resulting from a failure by Owner to maintain the interior of the building in a manner to avoid growth of mold. 6.8 Customer acknowledges that tear-off of existing roofing materials and re-roofing of an existing building may cause disturbance, dust or debris to fall into the interior. Customer agrees to remove or protect property directly below the roof in order to minimize potential interior damage. Jurin Roofing Services, Inc. shall not be responsible for disturbance, damage, and cleanup or loss of use or loss to PRJ#2290: Townview Center-TJ MAXX—Penthouse Removal Page 3 of 5 Corporate Office and Remittance: .. 2150 Rosedale Road, Quakertown, PA 18951 PA Contr.#PA019043 Florida Branch Office: 29716 US Highway 27, Dundee, FL 33838 Florida Contr. #CCC1325665 FL Business Lic. #23289 Jurin Roofing ServiCes, InC. Tel.(800)710-7525 Fax(215)536-2661 www.jurinroofing.com 6. Contract Provisions and Exclusions (conz) interior property that Customer did not remove or protect prior to commencement and during the course of roofing tear-off and re-roofing operations. Customer shall notify tenants and building occupants of re-roofing and the need to provide protection underneath areas being re-roofed. Customer agrees to hold Jurin Roofing Services, Inc. harmless from claims of tenants and occupants who were not so notified and did not provide protection. 6.9 Jurin Roofing Services, Inc. shall furnish the labor and materials necessary to perform the work described herein or in the referenced contract documents. Jurin Roofing Services, Inc. is not a licensed architect or engineer and does not provide architectural, engineering or consulting services. It is the owner's responsibility to retain a licensed architect or engineer to determine structural integrity and proper design, including that the design is in compliance with applicable ordinances, codes and regulations. If plans, specifications or other design documents have been furnished to Jurin Roofing Services, Inc. customer warrants they are sufficient and conform to all applicable laws and building codes. Jurin Roofing Services, Inc. is not responsible for any loss, damage or expense due to defects of plans or specifications or building code violations unless such damage results from a deviation by Jurin Roofing Services, Inc. from the contract documents. Customer warrants all structures to be in sound condition capable of withstanding normal activities of roofing construction equipment and operations and the work that is to be performed. Jurin Roofing Services, Inc. is not responsible for location of roof drains, adequacy of drainage or ponding on the roof. 6.10 This proposal is being submitted based upon standard roofing practices with the intention of providing long-term moisture protection. No consideration has been given to local building code requirements. Change to the specifications may be required in order to comply with local codes. Any changes to this scope of work in order to comply with code requirements will be considered a change order to the project. 6.11 Owner warrants that the structures on which Jurin Roofing Services, Inc. is to work are in sound condition and capable of withstanding normal activities of roofing construction equipment and operations. Owner represents that there is no electrical conduit embedded in the existing roofing or attached directly to the underside or topside of the roof deck upon which Jurin Roofing Services, Inc. will be installing the new roof. Owner will indemnify Jurin Roofing Services, Inc. from any personal injury, damage, claim or expense due to unsafe structural conditions and the presence of electrical conduit, shall render the conduit harmless so as to avoid injury to Jurin Roofing Services'personnel, and shall compensate Jurin Roofing Services, Inc. for additional time and expense resulting from the presence of such materials and unsafe structures. 6.12 Design Professional is responsible to design the work to be in compliance with applicable codes and regulations and to specify or show the work that is to be performed. Jurin Roofing Services, Inc. is not responsible for design, including calculation or verification of wind load design. To the extent minimum wind loads or pressures are required; Jurin Roofing Service, Inc.'s bid is based solely on manufacture's printed test results. Jurin Roofing Services, Inc. is not responsible for the construction of structural sufficiency of the roof deck or other building components not constructed by Jurin Roofing Services, Inc. PRJ#2290: Townview Center-TJ MAXX—Penthouse Removal Page 4 of 5 Corporate Office and Remittance: �. � 2150 Rosedale Road, Quakertown, PA 18951 PA Contr.#PA019043 Florida Branch Office: 29716 US Highway 27, Dundee, FL 33838 Florida Contr. #CCC1325665 FL Business Lic. #23289 Jurin Roofing ServlCes, InC. Tel (800)710-7525 Fax(215)536-2661 www jurinroofing.com 6. Contract Provisions and Exclusions (con�) 6.13 Building Permit Exclusion - The cost of the building permit, if required, is not included in the proposed price as noted. Jurin Roofing Services, Inc. will pull the permit on behalf of the owner. The cost of the building permit plus a handling fee of 10%will be added to the cost of the project if a building permit is required. This will be handled as a change order. 6.14 Jurin Roofing Services, Inc. is not responsible for leakage through the existing roof or other portions of the building that have not yet been reroofed by Jurin Roofing Services, Inc. Jurin Roofing Services, Inc. is not responsible for damages or leaks due to existing conditions or existing sources of leakage simply because Jurin Roofing Services, Inc. started work on the building. Notes: Unless stated otherwise on the face of this proposal, Customer shall pay the contract price plus any additional charges for changed or extra work within ten (10) days of substantial completion of the Work. If completion of the Work extends beyond one month, Customer shall make monthly progress payments to the Contractor by or before the fifth(Sth) day of each month for the value of Work completed during the preceding month, plus the value of materials suitably store for the project. All sums not paid when due shall earn interest at the rate of 1 1/12 percent per month. Contractor shall be entitled to recover from Customer all costs of collection, including attorney's fees, resulting from Customer's failure to make proper payment when due. Statement of Quality - All material is guaranteed to be the same as specified. All work is done in accordance with accepted roofing practices as determined by the NRCA. All extra work will be done through change orders and will be an extra cost above and beyond the stated price. All agreements are contingent upon delays beyond our control. Owner to carry all necessary fire, tornado, and other insurance. Our workers are fully covered by workman's compensation insurance. This proposal may be withdrawn if not accepted within 30 days of submission. Mr. Christophor Jurin President Jurin Roofing Services,Inc I� accept the above proposal on 20 Authorized Signature PRJ#2290: Townview Center-TJ MAXX—Penthouse Removal Page 5 of 5 , � � 1 � I � CARLISLE'S S�JRE�WELD� REINFORCED � � TPO MEMBRANE Carlisle's Sure-Weld tan and white TPO membrane can contribute toward LEED�(Leadership in Energy and Environmer�al Design)credits.Tan and white Sure-Weld are ENERGY STAR�*-qualified and California Title 24 compliant. Features and Benefits • Outstanding puncture resistance • Chlorine-free with no halogenated flame retardants .� • Plasticizer-free;does not contain liquid or polymeric plasticizers • Excellent low temperature impact resistance • Excellent chemical resistance to acids,bases and restaurant exhaust emissions Overview • Exceptional resistance to heat,solar UV,ozone and oxidation Carlisle Sure-Weld membrane is a premium heat-weldable single-ply • Low water vapor permeance and water absorption thermoplastic polyolefin(TPO)sheet designed for new roof construction and re-roofing applications.Sure-Weld High Slope(HS)membrane is ' Hot-melt extrusion processed for complete scrim encapsulation formulated with additional flame retardant(compared to Standartl)for • Warp-knitted fabric(not woven)for smooth surtace and greater higher-slope fire code approvals.Sure-Weld EXTRA is 80-mils-thick for thickness over scrim significantly higher strength and weatherability. • Sure-Weld is 100%recyclable Carlisle's Sure-Weld TPO membrane is based on advanced (refer to Carlisle's Recyclability Statement) polymerization technology that combines the flexibility of ethylene- propylene(EP)rubber with the heat weldability of polypropylene.All Installation Sure-Weld TPO membranes include OctaGuard XTT^^,an industry- leading,state-of-the-art weathering package.OctaGuard XT technology Sure-Weld Roofing Systems are quick to install as minimal labor and enables Sure-Weld TPO to withstand extreme weatherability testing few components are required.The systems may be installed utilizing intended to simulate exposure to sever climates. labor-saving devices that make sheet welding fast,clean,consistent and easy to learn,while reducing strain on the roofing technician. Physical properties of the membrane are enhanced by a strong polyester fabric that is encapsulated between the TPO-based top and The Carlisle Mechanically Fastened Roof System installation starts bottom plies.The combination of the fabric and TPO plies provides with the insulation fastened with a minimum of 5 fasteners per 4 Sure-Weld reinforced membranes with high breaking strength,tearing by 8 ft.board.The Sure-Weld reinforced membrane is mechanically strength and puncture resistance.The relatively smooth surtace of fastened to the deck using HP-XT"^Fasteners and Piranha PlatesT^^ Sure-Weld membrane produces a total surtace fusion weld that creates or HP-XTRA Fasteners and Piranha XTRA Plates.Adjoining sheets of a consistent,watertight monolithic roof assembly.The membrane is Sure-Weld membrane are overlapped over the fasteners and plates and environmentally friendly and safe to install. joined together with a minimum 1'/z-inch-(4 cm)wide hot-air weld. Sure-Weld Stantlard and HS products are available in highly reflective The Carlisle Fully Adhered Roofing System application begins white,tan and gray,in both 45-mil and 60-mil thicknesses.Sure-Weld with the insulation fastened at the required density(max.1 every 2 EXTRA(including HS)is available in 80-mil thickness,in white,gray sq ft)necessary to resist the appropriate wind load.The substrate and tan.Sixteen special colors are also available(see Carlisle's TPO and membrane are coated with an appropriate Sure-Weld Bonding Color Palette brochure).Available widths are 4-,5-and 6-ft perimeter Adhesive and the membrane is rolled into place. sheets and 8-,10-and 12-ft field sheets. * CONSULT CARLISLE SPECIFICATIONS FOR COMPLETE INSTALLATION INFORMATION. Investing in Roofing Solutions for 50 Years 500-479-6832• PO Box 7000• Carlisle,PA 17013 • Fax:717-245-7053•www.carlislesyntec.com � � — Carlisle SynTec ' ll � � � � CARLISLE'S S�IRE�WELD REINFORCED � � TPO MEMBRANE Precautions 4. Use proper stacking procedures to ensure sufficient stability of the rolls. 1. Sunglasses that filter out ultraviolet light are strongly recommended as tan and white surfaces are highly reflective. 5. Exercise caution when walking on wet membrane.Membranes Roofing technicians should dress appropriately antl wear may be slippery when wet. sunscreen to protect skin. 6. Store Sure-Weld membrane in the original undisturbed plastic 2. Surtaces may become slippery due to frost and ice buildup. wrap in a cool,shaded area and cover with light-colored, Exercise caution during cold conditions to prevent falls. breathable,waterproof tarpaulins.Sure-Weld membrane that has been exposed to the weather must be prepared with Weathered 3. Care must be exercised when working close to a roof edge when Membrane Cleaner prior to hot-air welding. surrounding area is snow-covered as the roof edge may not be clearly visible. � ' • � • � ' 1 � „ ,. ,, �_ .. .., ., , , , ; , : �_ . �� �.,� , „ .. .. ,�,„ . �= .,:.- ,. �r �` v, ,�'�� ., _:. __ ,, , „ �,. .., ' �. _ ,._.:-,. _„ ,-_- . - "^, , ..:„ ,.,t,., � , H... ,. ._� :, Tdaranoe on roomir�ei tlNduiess,% +15,-10 s 10 s 10 s 1p ASTMl1751 test lnetlwd Tl�Cicness arer sc�im,in.(mm) OA�5+� 0.018 typ O.OY!typ 0.034 typ ASTM�18878 optkel methDd, (0.381) (0.45� (0.6101 {0.864) • avereye�Df 3 a[�s Breekin0 srenydt,�f(kN) 220(978 N) ,226{1.0)min 250�9.1)aNn $50�1.8)nfin AS'fM D751 pr�7netlxtd t►�n 32011.4)ty� S8l1(16)tYP 425(1�?t� 8ony�dion broedc afi.�eM�iL 15 mN► 15 mk� 15 min 15 min ASTM tl751 gr�ntetlMDd 25#yP 2fi tyD 25 h�p Teari�y�lp�.ibf(N� 55(245)min 85 j245)min 85(�ai5�m� 55{�)�pin asnA ors��►oc.e a�.X e�,. ��ts�sa�p isQ�s�s��rP �so is�e��ro er�ca�,e�e�,t,�t°c� -�o t-�oj max -�o{-�wy�ax .4o t-�o�mex «w�.�oj„rex ' AS7M 02137 -50(-�81 h�P b0 l-46)tyP -fi0(-�{6)tyP L:iMar tlimOlqidml ChM1qe.9G t 1 11�x s 1 Imeu *1 a�a�c *1 m9x AS'f#1 D1204,8 fiours si 158°F -0.2 hiP -03 tyP -0.2 hiP Qmrk�Ce.nDCradcs 7�f PASS PASS PASS PA'SS AST1A D]149.,1�DP�►,1$8 Ms wahr�De�a+r�,m��. t SA mox t 3.0 rt�x . , t 3'9�x �_.^ �_.,.-s 3.�maic �� ASt'Mi�li1�OP wfaoe+� 2.0 h�V ZDtYP 2.D t4A 186 Mur6�if+8°F w86pr Fecto�r aesm atronpn���+(kN�m1 ss{2so)a� �t29o)m�n 86 t�)� Ss(290)a�n ASTM 07514�ab method peld a�+atreiqtli�N�f/Yf ticN/m) No roqulrement 25(4.4f min 25{4.4)min �40(7.0)� � ASTIid 01876 teSteli&1 P� 50 i8.8)tYP 80(1Q5)tf'D 70(12 3)'!YD W�'�Aern�.Perms No ropukennent �.i0 max 0.10 maa� fl.10 msx AS7M�6 Droc.B OAS ifrP 0 Q5 h9► 0.45 fyR Purwhire ree�tance,Ibf(kN) No reVuire�nent 280{1.1)min 800{t.8)� �it.8)min FiM/�1C.mOtliod 2091 325(1.4I�YP 850(1.5)hiP 450{2.0)h�D (see�bma►tai sectlonl Propertbs t�ter heat apNq ASTM Db73,82 weeks�240°F Breakle0 atrengtli,%retafned 90 min 90 mM 90 min 90 min Elor�padan rei�.,96 retair�ed 90 min 90 min 90 mM 90 min Tearinp Strength,96 retained 60 m� 60 m� 60 min 60 mfn WeigM d�ange,9f, s 1.0 max s 7.0 max *1.0 max s 1.0 max TYa�We�9Ms 0.231b/ft�(1.1 kg/m2) 0.29(1.4) 0.40(2.0) * Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. Investing in Roofing Solutions for 50 Years 800-479-6832• P 0 Box 7000 •Carlisle,PA 17013• Fax:717-245-7053•www.carlislesyntec.com � � - Carlisle SynTec � , � � ' I I � CARLISLE'S S�IRE�WELD REINFORCED � � TPO MEMBRANE Extreme Testing For Severe Climates ASTM Standard D6878 is the material specification for Thermoplastic Polyolefin Basetl Sheet Roofing. It covers material property requirements for TPO roof sheet and includes initial and aged properties after heat and xenon-arc exposure.As stated in the scope of the standard, "the tests and property limits used to characterize the sheet are values intended to ensure minimum quality for the intended purpose."Carlisle's goal is to produce TPO that ensures maximum pertormance for the intended purpose of roofing membranes.Maximum performance requires the membrane to far exceed the requirements of ASTM D6878.For severe climates like Miami,FL and Phoenix,AZ,EXTREME testing is required. Heat Aging accelerates the oxidation rate that roughly doubles for exposure.The acid fog accelerates acid etching that may occur from each 10°C(18°F)increase in roof inembrane temperature. Oxidation acid rain if the roof inembrane is not resistant to acidic conditions. (reaction with oxygen)is one of the primary chemical degradation • ASTM requirement—none mechanisms of roofing materials. • Carlisle EXTREME test*• � � � � ,-: ,,{,.,,,, ,;�,� ,,f.,. .. � • 10 days heat aging at 240°F(116°C)followed by ` �"�'' � - • 5 days water immersion at 158°F(70°C)or with another ASiM TEST ?40°F 32 w90k8 x b2 weeks specimen set �r t� 27�F ��A 13� • 5 eight-hour cycles in Kesternich sulfur dioxide chamber (sulfurous acid fog)followed by • Test specimen is 1"by 4"piece of 45-mil membrane unbacked, • 5040 kJ/m2(2000 hrs at 0.70 W/m2 irradiance)xenon-arc placed in circulating hot-air oven. exposure *Test specimen is 2.75"by 5.5"piece of inembrane with edges sealed. • Criterion—no visible cracks after bending aged test specimen around 0.25"-diameter mandrel. *Criterion—after 3 complete cycles,test specimens shall remain flexible and not have any cracking untler 10x magnification while Xenon-Arc exposes the membrane samples to the combined effect wrapped around a 3"-diameter mandrel. of ultraviolet,visible and infrared radiation as well as ozone,heat and water spray,to greatly accelerate the effects of outdoor weathering. The radiation dose is measured in kilojoules per square meter(kJ/ m2)at 340 nm machine UV wavelength.The irradiance power of the xenon-arc lamp is measured in Watts per square meter(W/m2). � � � � ,� ,�,y�v���� ,, . , r, a_�,a m s,_=K.� tr"_,�--,,� — ASTM 1EST �T 46-MML e0-�All !0-� kJ/m=at 3d0 nm 10.a80 17,640 20,960 27,720 • Test specimen is 2.75"by 5.5"piece of inembrane,unbacketl, weathering side facing arc lamp. • Criterion—no visible cracks viewed under 10x magnification while wrapped around 3"-diameter mandrel. Environmeirtal Cycling subjects the membrane to repeated cycles of heat aging,hot-water immersion or acid fog followed by xenon-arc Investing in Boofinq So/utions for 50 Years 800-479-6832• PO Box 7000• Carlisle,PA 17013 • Fax:717-245-7053•www.carlislesyntec.com � � ' Carlisle SynTec , � � 1 I I � CARLISLE'S SIJRE�WELD REINFORCED � � TPO MEMBRANE Supplementai Approvals, Statements 3. Sure-Weld TPO membranes conform to requirements of the and Characteristics: U.S.E.P.A.TOxic Leachate Test(40 CFR part 136)performed by an independent analytical laboratory. 1 Sure-Weld TPO meets or exceeds the requirements of ASTM D6878 Standard Specification for Thermoplastic Polyolefin Based 4. Sure-Weld reinforced TPO was tested for dynamic puncture Sheet Roofing. resistance per ASTM D5635-04 using the most recently modified impact head.45-mil was watertight after an impact energy of 2. Radiative Properties for ENERGY STAR,Cool Roof Rating Council 1 p,5 J(9.2 ft-Ib�and 60-mil was watertight after 22.5 J(16.6 (CRRC)and LEED. ft-Ib�.Both 72-mil and 80-mil EXTRA products were watertight after an impact energy of 30.0 J(22.1 ft-Ib�. ElI�YSiAN S41et3pechvm 0.87 U.68 WA ir�ial�ralpc�rtce RBii�CtDn�tlfier H�i'Y ST�IR iN� SoMr SpeCbtNn 0.83 0.64 N/A ader re� RefleCtanete� aRer 3 f� i�r deanio0) i�qi6 kd681 AS'fM C1549 0.79 0.71 0.46 aoNr rolleCtar� t�RC soler rotl�mnce AST#A Cy549 0.70 0.84 0.43 aikr 8 Years 1an�ned) t�i1C h�itlal ASTIYI C1371 0.90 0.86 0.90 tlfelrilal±e�dttance (�HG titer�led ASTM Ct371 0.86 0.87 0.88 amttter+oe erter 3 Y� i�dl t�tl�ennai�duae ASTM E408 0.95 0.� 0.95 SRI 15aler�NidBIQ AS�M�1980 170 86 55 Solar Reflectance Index(SRI)is calculated per ASTM E1980.The SRI is a measure of the roof's ability to reject solar heat,as shown by a small temperature rise.It is defined so that a standard black(reflectance 0.05,emittance 0.90)is 0 and a standard white(reflectance 0.80, emittance 0.90)is 100.Materials with the highest SRI values are the coolest choices for roafing.Due to the way SRI is defined,particularly hot materials can even take slightly negative values and particularly cool materials can even exceed 100. � � Pre-carreNru�Rbcyded Coldetd 10�6 Post-co�ltmer Recyi�ed Caneni 0!6 MenufaCi�xNtp LacedOn SenStC�.MS Tooele,UT Sder RAfleCtenCB I�ex 71� Investing in Boofing So/utions for 50 Years � � 800-479-6832• P0 Box 7000 • Carlisle,PA 17013• Fax:717-245-7053•www.carlislesyntec.com ' Carlisle,Sure-Weld,Octaguard X7,Piranha Plates and HP-X are trademarks of CaAisle. ENERGY STAR is a registered trademark awned by the U.S.Govemment.LEED is a trademark of the U.S.Green Building Cauncil. ria��l$�e.SynTeC 'ENERGY STAR qualification is onty valid in the U.S REPRINT CODE:600515-"Sure-Weld Reinforced TPO Membrane Product Data SheeY'-021812�2012 Carlisle. � � 11 � , . Tpo �o pvc �oW-voc ADHESIVES AND SEALANTS Increased governmental regulations,combined with the low-VOC requirements of LEED�and other environmentally conscious programs,have caused a shift in the construction community towards the use of low-VOC products.The roofing industry is certainly not excluded from these changes.To qualify for low-VOC status,an adhesive must have a VOC content of 250 grams/liter or less,and a sealant must have a VOC content of 450 grams/liter or less.However,certain products are excluded from the VOC content requirement based on packaging size,vapor pressure or other reasons. Carlisle is leading the way in meeting the growing number of VOC regulations.Carlisle is continually developing products that meet the low-VOC requirements of new governmental regulations and green building codes.The following products meet the current limitations of known regulations as of the publish date. Low-VOC Bonding Low-VOC Bonding Adhesive �`�`°� � Adhesive 1168 - � �� ,� _ is a high-strength solvent-based is a high-strength solvent-based contact adhesive that allows bonding ' contact adhesive that allows bonding of Carlisle TPO membranes to various " of Carlisle TPO membranes to various porous and non-porous substrates.tt porous and non-porous substrates. ��� is specially formulated using a blend Low-VOC Bonding Adhesive 1168 is �'�•- 6�� of VOC-exempt and non-exempt compliant for use in all CA counties. -- solvents that are ideal for use where °°�' low-VOC products are required. Low-VOC Bonding Adhesive 1168 is available for use in Califomia. 'Proper mixing is required i 1 : � � � + � i 1 : � � � � � �: � .. �M A�.r, .,� �,r. voc co�n xso�uce�� % voc ca�a zso oramsn�r�aX Pe�k�N�O 5-pallon paii Packayle0 5-OaNOn pail Sl�elf Ufe t year Sheif LHB 1 year Aqua Base 120 Low-VOC PVC is a unique,semi-pressure-sensitive, - `�`�°'""��" B011dlllg Adh@SIV@ water-based bonding adhesive for U Carlisle's Low-VOC PVC Bonding certain FleeceBACK�,TPO and PVC Adhesive is a high-strength membranes offering superior peel ,,,.,.,` solvent-based contact adhesive that strengths without VOCs or strong odors. ;^� allows bonding of PVC and KEE- Aqua Base is installed using a one- enhanced PVC membranes to various sided wet lay-in application for porous and non-porous substrates. FleeceBACK membranes.Aqua Base This product is also approved for 120 can also be utilized as a contact use in CA. adhesive for TPO and PVC membranes.Coverage rate is 100 sq.ft.(9 sq. meters)per gallon and it is packaged in 5-gallon pails. ' ' � � 1 : i � � � � �'1/1C�.< , ,� .� ,,,• �a�;: , ., . .. ,, -, , ,. - , ,�;��,. �� ��".a = VOC CoMent 8 grams/ifter 'VOC 6o�eM 250 grams/Ilter max Packaging 5-gallon pail Pack�i� 5-gallon pafl Shelf Llfe 1 year Shelf Llfe i year 800-479-6832•P.0 Box 7000•Carlisle,PA 17013• Fax:717-245-7053•www.carlislesyntec.com � SYNTEC SYSTEMS • , � � 1 I I TPO aN� PVC Low-VO C ADHESIVES AND SEALANTS Low-VOC TPO Primer Weathered is a low-solids,clear,solvent-based ti,� � Membrane Cleaner p r i m e r u s e d t o p r e p a r e T P O �T p p is use d to c lean b ot h new an d e,:-=_- mem brane for a d hesion to pressure- �-==� S in-service membrane.It helps to sensitive TPO coverstrip and RUSS �"_=_� � � loosen and remove dirt and other � ° where VOC regulations or restrictions e_--=� c �- a.'�"'""'.. contaminants from the surface of � exist. = _=;� `— the membrane and leaves a suitable � ��-= surtace for primer application or l�j welding. 'Note:This product is not compliant in CA. � 1 ' 1 ' •� � ' 1 ,, ., . ..A, ,� . �4.; ;�x.,, �,, . , .. . .. �.. �.,.r�� �,�,.,. . ;, .r „ , , . VOC Content 250 qrams/�ter max VOC CordeM Exempt based on vapor presaure' padca9�og (6)1-gaNa�can Packagin9 5-qallon closed-top pail or Shelf ufe t year in unopened can (2)�-O�Ion cbaed-MA P� Shelf Life N/A � � ' . . �"; -., - �..��;_ ,��.._.a k�Y+ ,_. ., .x,:. VOC CoMeM VOC Exempt Packa�ng 5-pallon can Shelf Lffe N/A SATTM TPO Membrane a heat-weldable single-ply Clear Cut Edge � thermoplastic polyolefin(fP0) Sealant sheet designed for fully adhered 'j applications.The 100%solids,hot- , a medium solids,free-flowing, melt pressure-sensitive adhesive polymeric material designed to be eliminates VOC and odor concerns � used for sealing cut edges of Carlisle's typically associated with fully adhered TPO or PVC membranes.Qualifies systems. for small quantity exemption in most areas. � 1 � � � 1 ,; y�'°�'': YOC ConteM nare VOC CaMeM Exempt for small quantity Packeging 10'x 100',50' P�kaping (8)16-oz.batdes/ctn Shelf IJfe t year Shetf LMe 1 y�r � � �„ , . . ._. , � � s ,,,...�m �� , <w VOC CoMeM Exempt for small quantity Packagki9 (12)16-oz.battles/ctn Shelf Life i yeer 800-479-6832•P.0 Box 7000• Carlisle,PA 17013• Fax:717-245-7053•www.carlislesyntec.com � SYNTEC SYSTEMS II � II . ' ' ' I I Tpo �o pvc �oW-voc ADHESIVES AND SEALANTS Universal Single-Ply ,,�a ._..s..;;, White One-Part Sealant �� Pourable Sealer - is a 100�o-solids,solvent-free,one- £G,.: part,polyether sealant that provides e`� e` ia single-componeM,moisture- � , _ , a weathertight seal to a variety of curing,elastomeric polyether «���^ _ sealant that is compatible with ��LL--= =.�;:= building substrates and can be used all Carlisle roofing systems and � ,�, �, .;�'' � as a termination bar sealant for provides a watertight seal around Carlisle's EPDM,TPO and PVC hard-to-flash penetrations. roofing systems. � � � 1 � � s°°' _ ��re, � w,.� ... �,o ; ,,;::. ,.p . ._..;. rr�,; „ ;r,,., ,.:�4,� _ ,._ ;_„ VOC Content 0 grams/Ifter VOC ConteM 0 gramsRfter PaCkaging 24 cartridges,10.1 fl.oz.each Peckaging (4)Ye-gal pouches per W�cket Shelf LHe 7 year in unopened container Shelf LHe 18 months Water Cut-Off Mastic iiui�� CAV-GRIpTM is a one-component,low-viscosity, is a Low-VOC,methylene chloride- self-wetting butyl blend mastic used with free,multi-purpose contact adhesive/ roofing and waterproofing systems,and primer recommended for enhancing when a membrane is being terminated the bond of Carlisle's 725TR. using a compression-type seal. CAV-GRIP is also used as a primer for unweathered asphalt. 1 , �. VOC Content 250 qra�/�ter max VOC CoMent 71�ams/liter ����9 25 4�es�carton Padcaping 40-Ib aeroaol cylinder Shelf Lfle 1 year in unopened container Shelf Llfe 1 year in unopened coMainer 800-479-6832•PO Box 7000•Carlisle,PA 17013• Fax:717-245-7053•www.carlislesyntec.com � SYNTEC SYSTEMS ' � � 11 � , � Tpo �o pvc �oW-vo c ADNESIVES AIVD SEALANT S FASTTM Adhesive Flexible FAST is a low-rise,iwo-component, Adhesive insulating polyurethane adhesive.tt is a low-rise,two-component, can be used to adhere a varieiy of insulating and energy-absorbing insulations and Carlisle's FleeceBACK polyurethane adhesive with 150�0 membranes,and is applied in full elongation to better handle building spray or beads. movement and roof system expansion and contraction. � � , � , , � ��� � ,�, �. - �.� �. _� YOC Cor�aM 0 grams/li[er � VOC Cor�ent .. , 0 prams . k q§ , /titer Packeging 15-and 50-gaWon drums,Bag-in-a-BOx end Dual Peckaging 15-and 50-gallon drums(Part A and 8) Cartridges(Part A and B) g�ff�e 1 year(Part A and B) Sheif IJfe 1 year(Part A and B) Cold Applied � CCW-702LV Primer _ Adh@SIV@ ��":_,:�,:;.^,;-:;�.._r.�.,,�, is a quick-drying,solvent-based, is an asphalt-modified polyether, _ high-tack adhesive/primer specifically one-sided,wet lay-in adhesive designed to promote maximum designed to adhere to AFX membrane adhesion of Carlisle's 725TR Air and Carlisle's modified base sheet. and Vapor Barrier � i � � � •� � � � VOC CoMent 32 grams/Nte� VOC ConteM 250 pramaAlter m8x ��°g 5"9aHa�Pe�� P�kaO��g 5-gaNOn pall Shelf LHe 9 mordhs Shetf Lxe 1 yeer In unoper�ed coMalner *Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product.This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. 800-479-6832• P.0 Box 7000•Carlisle,PA 17013•Fax:717-245-7053•www.carlislesyntec.com � Carlisle,SAT,Sure-Weld,Sure-Seal,Sure-Whlte,Sure-TOUgh,FleeceBACK,FAT,FAST,SecurTAPE,CAV-GRIP a�In-Seam SealaM are tretlemarks of Carlisle. syivTec sYSTeMs LEED is a registe2d t�ademark of the U.S.Green Buiftling Council. REPRINT CODE:600262-7Po and PVC Low-VOC Atlhesives and Sealants Product Data Sheet-08.23.12 m 2012 Carlisle. � • DATE(MMIDD/YYY1� ACOR� CERTIFICATE OF LIABILITY INSURANCE 03/05/2013 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement s . PRODUCER NAME: Michael E.Santarsiero PHONE , g14 412-0559 aC Na; 914 381-1134 c/o Kevin Spero Whitelaw,Inc. E.�,�Ai� 500 Mamaroneck Ave. nooreess: Harrison,NY 10528 INSURER S AFFORDING COVERAGE NAIC# iNSUrtertn: Zurich-American Insurance Company 16535 INSURED INSURER B. DSK Group,Inc.et al Alt.Emp:C&C ELECTRICAL CONTRACTORS INC �NSURER C: dba:C&C ELECTRIC of TAMPA BAY,INC 6715 W Grover Cleveland Blvd INSURER D: Homosassa,FL 34446 INSURER E: INSURER F. COVERAGES CERTIFICATE NUMBER:12FL076799792 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TypE OF INSURANCE �DL SUBR POLICY EFF POLICY EXP LIMITS lTR POLICY NUMBER MM/DD MMIDD/YYYY GENERAL LIABILITY EACH OCCURRENCE $ COMMERCIAL GENERAL LIABILIN DAMA E T RENTED PREMI ES E cc rrence $ CLAIMS-MADE � OCCUR MED EXP(My one person) $ PERSONAL 8 ADV INJURY $ GENERALAGGREGATE $ GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $ POLICY PR� LOC $ AUTOMOBILE LIABILITY M IN D IN LE LIMI Ea accident ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS NON-0WNED PPe�a c dentDAMAGE $ HIRED AUTOS AUTOS $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ WORKERS COMPENSATION X WC STATU- OTH- AND EMPLOYERS'LIABILITY Y 1 N �' ANY PROPRIETOR/PARTNERlEXECUTIVE E.L.EACH ACCIDENT $ 'I,OOO,OOO A OFFICERlMEMBER EXCLUDED? � N�A WC 40-51-06&05 10/25/2012 10l25/2013 (Mandatory in NH) E.L.DISEASE-EA EMPLOYE $ 1,DU�,UO� If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,000 Location Coverage Period: 10/25/2012 10/25/2013 Client# 35-FL DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101,Additlonal Remarks Schedule,N more space Is requirod) Coverage is provided for C&C ELECTRICAL CONTRACTORS�NC dba:C&C only those employees ELECTRIC of TAMPA BAY,INC leased to but not 15915 N Florida Ave subcontractors of: Tampa,FL 33549 CERTIFICATE HOLDER CANCELLATION CITY OF ZEPHRYHILLS-BLDG.DEPT SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 5335 8TH STREET THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ZEPHYRHILLS,FL 33542 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE i��� �O 1988-2010 ACORD CORPORATION. All rights reserved. I IIIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII II 20130g2219 IIIIIIIIIII Permit No. Parcel ID No 35-25-21-0010-08800-0000 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following infortnation is provided in this Notice of Commencement: 1 Description of Property Parcel Iden6fication No. 35-25-21-0010-08800-0000 Street Address: TJ MAXX-7326 Gall Blvd.,Zephyrhilis FL 33541 cpt:1523466 ReC: 10.00 O5: 0.00 IT: 0.00 2. General Description of Improvement Roof Replacement 0�5/24/13 B. McBee, Dpty C 1 erk PqULR S 0'NEIL,Ph D PRSCO CLERK 8 COMPTROLLER 3. Owner Infortnation or Lessee infortnation if the Lessee contracted for the improvement: _�5�24�13 11:g8am 1 Of 1 Townview Retail,LLC OR BK $��� PG 121? Name 725 Conshohocken State Road Bala Cynwyd pq Address City State Interest in Property �Wner Name of Fee Simple Titleholder (lf different from Owner listed above) Address Ciry State 4. Contractor Jurin Roofing Services,Inc. Name 29716 Highway 27 Dundee FL Address City State Contractor's Telephone No. 800-710-7525 5. Surery Name Address City State Amount of Bond: $ Telephone No. 6. Lender Name Address Ciry State Lender's Telephone No. 7 Persons within the State of Florida designated by ihe owner upon whom notices or other documenis may be served as provided by Section 713.13(1)(a)(7),Florida StatuTes: Name Address City State Telephone Number of Designated Person: B. In addition to himself,the owner designates of to receive a copy of the Lienofs Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner 9. Expiration date of Notice of Commencement(the e�iration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a diffe ht date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER F1+ER E EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 7 3, P R 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO Y UR, QPERTY A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE J08 SITE BEFORE THE FIRST I S IQN. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING W l�ECORDING YOUR NOTICE OF COMMENCEMENT Under penalty of perjury,I declare that I have read the foregoing notice�c e mea�t and thet the fa tated therein are true to the best of my knowledge and belief. � STATE OF PENNSYLVANIA i /� COUNTY OF Signature of 0 o Lessee,or wnefs or Lessee's Authorized Officer/Director/Part /Manager � Authaized Prtson Signatary's Title/Office The foregoing instrument was acknowled ed b�efore�m,,Ie this z�daQy of �� 2013,by�p�°,/7 L Pwf S ' as �//Wl J �� `['-� (type of authority,e.g.,officer,trustee,atromey in fact)for '��n���������� L�� ( f party on be of whom instrument was executed). Personally Known�QR Produced Identification❑ Notary Signature /1.�-- Type of Identification Produced Name(Print) /�C-)/7c..J/ �1 •�k�c7n Commonwealth of Penns Ivanl� NOTARIAL SEAL wpdata/bcs/noticecommencement_pc053049 RANDI SHENKMAN,NOTARY PUBUC Lower Merion Township,Montgomery Coue Commission ires A 8 2015