HomeMy WebLinkAbout13-13961 CITY OF ZEPHYRHILLS
' , 5335-8TH STREET
` (sss)�so-oo20 13961
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
Permit#:13961 Issued: 6/10/2013 Address: 7326 GALL BLVD
Permit Type: GENERAL BUILDING PERMIT ZEPHYRHILLS, FL.
Class of Work: ADD/ALT COMMERCIAL Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 15,600.00 Total Fees: 172.50 Subdivision: CITY OF ZEPHYRHILLS
Amount Paid: 172.50 Date Paid: 6/10/2013 Parcel Number: 35-25-21-0010-08800-0000
Name: JURIN ROOFING SERVICES INC Name: TOWNVIEW RETAIL LLC
Addr: 2150 ROSEDALE RD Address: 725 CONSHOHOCKEN STATE RD
QUAKERTOWN, PA 18951 BALA CYNWYD PA 190042102
Phone: (215)536-1886 Lic: Phone: (610)667-5800
Work Desc: REPAIR/REROOF PENTHOUSE AFTER REMOVAL PDT#FL14083-R3
r )
�c-
. . 2-� __ � 3
�
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPEC7ION FEES: Reinspection fees will comply with Florida Statute 553.80(2)(c)when extra inspection
trips are necessary due to any one of the following reasons: a)wrong address b)condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d)work not ready for
inspection when called e) permit not posted on job site� plans not at job site g)work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to reaord a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application. All work shall be pertormed in accordance
with Ci Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
�
� �
CONT RS SIGNATU E PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
, ' Building Departrnent
Date Received _Sf_ 3 phone Contact for Permitting 215 529 _ 4151
� � � � � � � � � � � � �
Owner's Name Townview Retail L�C Go Stoltz RE Partner LLC pyrner Phone Number 610-667-5800
Owner's Address 725 Conshohocken State Road,Bala Cynwyd,PA 19004 pWner Phone Number
Fee Simpls Tttleholder Name Townview Retail LLC c/o Stdtz RE Partner LLC Owner Phone Number
Fee Simple Titleholder Address 725 Conshohocken State Road, Bala Cynwyd, PA 19004
JOB ADDRE3S 7326 Gall Blvd., Zephyrhills, FL 33541 (Townview Square-TJ Maxx) LOT# ��
SUBDIVISION �— —� PARCEL ID# 35-25-21-0010-08800-0000
�OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED e NEW CONSTR 8 ADD/ALT � SIGN � � DEMOLISH
INSTALL REPAIR
PROPOSED USE Q SFR � COMM � OTHER
TYPE OF CONSTRUCTION Q BLOCK Q FRAME Q STEEL Q
DESCRIPTION OF WORK Roof repair after penthouse removal (see attached scope of work)
BUILDING SIZE N�A SQ FOOTAGE N�A HEIGHT N�A
�BUIIDING $ 15,GOO.00 VALUATION OF TOTAL CONSTRUCTION
OELECTRICAL $ AMP SERVICE Q PROGRESS ENERGY Q W.R.E.0
�PLUMBING $
QMECHANICAL $ VALUATION OF MECHANICAL INSTALLATION �-�1 ( � �" �
1'
�GAS � ROOFING Q SPECIALTY � OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE Af2EA �YES NO
'� . . . . . . .
BUILDER '��� COMPANY �urin Roofing Services, Inc.
SIGNATURE REGISTERED Y! N �E CuRRen Y!N
nddress 29716 Highway 27, Dundee, FL 33838 �icense# CCC1325665
ELECTRICIAN � COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREt� Y/N
Address License# �—
PLUMBER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREA Y/N
Address License# �—
MECHANICA� COMPANY
SIGNATURE ___� REGISTEREp Y/ N FEE CURRE� Y/N
Address License# � �
OTHER COMPANY
SIGNATURE REGIS7ERED Y/ N FEE WRRE� Y/N
Address License#
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIItllllllllll
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(i0)worlcing days after submittal date. Required onsite,Construction Plans,Stormwater Plans w!Silt Fence installed,
Sanitary Facilities 8 1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Fortns.R-O-W Permit for new construction.
Minimum ten{10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities 8 1 dumpster Site Work Pertnit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
*"'PROPERTY SURVEY required for all NEW construction.
Directions.•
Fill out applicadon completely
Owner 8 Contractor sign back of application,notarized
If over 52500,a Notice of Commenceme�t is required. (NC upgredes over 57500)
" Agent(for the cwit�actor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (Front of Application Only)
Reroofs ff shingles Sewers Service Upgrades AJC Fences(PIoUSurveylFootage)
Drlveways-Not over Cou�ter if on public roadways..needs ROW
NOTICE.OF DEED RESTRICTIONS� The undersigned understands that this permit may be subject to"deed" restrictions"
' w,hich may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this appfication for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT• I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill
- Use of fill is not allowed in Flood Zone"V" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FL(�RIDA JURAT(F.S. 117 03)
OWNER OR AGENT CONTRACTOR �urin Roofing Services, Inc.
Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmedl before me this
bY 4th day of March, 2013 by Eric W.Jurin
Who islare personally known to me or has/have produced Who is/are personally known to me or has/have produced
as identification. as identification.
/
Notary Public Notary Public
Commission No. Commission No. 1218006
Laura M Wertman
Name of Notary typed,printed or stamped Name of Notary typed,prirL,t���,m��NNSYLVANIA
NOTARUL SEAL
LAURA M.WERTMAN,Nota�y Public
Qus�tertown Boro.,Bucks County
Comrtaasion E ' A st 31,2013
. ,�``��' ���
�� -��- �
.�.
I
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: ��`� �� ��` ����'('-
Date Received: 3�"���3
Site: � _� �' �/4 /� ��� ��
_
Permit TYpe: ����?L�i t� ����r ��2e r�n'tcL��
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
i �
_ � �?����
� �� � � �-
� C�l '1�(. I�� �'*�J�' �' l.rcn!°P
,
' � ;✓�-�C l tii,� ,�i���
�
,
�,� r�>;����' ���� ��� � 1
�<<
� � c.��2v�!`�-�G� � r� �n��c�/� ���, ��, L ����;� 'cC
� 3 .�,-� 3
This comment sheet shall be kept with the permit and/or plans.
�'� �
Kalvin witzer— s Examiner Date Contractor and/or Homeowner
(Required when comments are present)
Corporate Office and Remittance:
+. 2150 Rosedale Road, Quakertown, PA 18951
PA Contr #PA019043
Florida Branch Office:
29716 US Highway 27, Dundee, FL 33838
Florida Contr. #CCC1325665 FL Business Lic. #23289
Jurin Roofing Services, Inc. Tel.(800)710-7525 Fax(215)536-2661 www.jurinroofing.com
Proaosal - Reaairs
Stoltz Management Date: 03/04/2013
725 Conshohocken State Road
Bala Cynwyd, PA 19004 Buildinq:
Townview Center—TJ MAXX
7246 Gall Blvd.
Zephyrhills, FL 33541
Job: PRJ#2290: Townview Center- TJ MAXX—Penthouse Removal
Price: Demolition............. $14,400
Roof Repair........... $15,600
TOTAL................. $30,000
Work To Be Performed:
Removal of Penthouses from Roof Surface
1. Mobilization
1.1 Setup site to meet OSHA fall protection requirements. This will include setup of various items
including enclosed trash chute, warning lines, and guard rails at load and discharge points. All safety
equipment being setup on site is for the sole use of Jurin Roofing Services, Inc. and is not intended for
use by others. Jurin Roofing Services, Inc. is not responsible for the safe conduct or safety of other
personnel on site.
1.2 Load all materials onto roof surface via crane or boom lift. Jurin Roofing Services, Inc. will make
maximum efforts to limit the storage of materials and equipment on the ground during the construction
proj ect.
1.3 Provide temporary toilet facilities for the duration of the project.
1.4 Prior to the commencement of the project, Jurin Roofing Services, Inc. requests a pre-construction
meeting between the owner's representative and the Jurin Roofing Services, Inc.'s project manager to
discuss all project details prior to start.
1.5 Any disconnection/reconnection of existing roof top mounted equipment or equipment mounted directly
to the underside of the roof deck is the responsibility of the building owner and is not included in this
scope of work. Owner agrees to have an electrician or other contractor certify that all power and other
feeds into these penthouses has been properly disconnected and that all lock-out/tag-out requirements
are met. Owner agrees to hold harmless and indemnify Jurin Roofing Services, Inc. free of all
liabilities as the result of the building owner's or manager's failure to disconnect equipment when
requested by Jurin Roofing Services, Inc. Jurin Roofing Services, Inc. must provide 24 hours notice
of disconnect/reconnect requirements when possible.
PRJ#2290: Townview Center-TJ MAXX—Penthouse Removal Page 1 of 5
Corporate Office and Remittance:
M � 2150 Rosedale Road, Quakertown, PA 18951
PA Contr.#PA019043
Florida Branch Office:
29716 US Highway 27, Dundee, FL 33838
Florida Contr #CCC1325665 FL Business Lic. #23289
Jurin Roofing Services, Inc. Tel. (800)710-7525 Fax(215)536-2661 www.jurinroofing.com
2. Demolition
2.1 After confirmation that all electrical and other feeds into the penthouses have been disconnected our
team will remove all equipment from the interior of the penthouses. This includes piping, conduit,
lighting, and all other equipment mounted to the interior of the penthouses.
2.2 All exterior metal siding and roofing material will be removed from the structure.
2.3 The penthouse frame will be removed.
3. Framing
3.1 Install new wood blocking as a horizontal ledger around the perimeter of the penthouse on the concrete
wall which is currently in place.
3.2 Install new wood framing into opening to support decking.
3.5 Install .5" plywood decking over the framing members.
5. Roof Installation
5.1 Install fully adhered .045 white TPO roof inembrane.
5.2 Perimeter edge of roof inembrane will be fully terminated with application of aluminum termination bar.
6. Contract Provisions and Exclusions
6.1 Asbestos, lead based paint, and toxic materials exclusion - This proposal and contract is based upon the
work to be performed by Jurin Roofing Services, Inc. not involving contact with asbestos-containing,
lead based, or toxic materials and that such materials will not be encountered or disturbed during the
course of performing the re-roofing work. Jurin Roofing Services, Inc. is not responsible for
expenses, claims or damages arising out of the presence, disturbance or removal of asbestos-
containing, lead based, or toxic materials. In the event such materials are encountered, Owner will
make arrangements with others for the handling and/or removal of such materials and/or Jurin Roofing
Services, Inc. shall be entitled to additional time and compensation for additional expenses incurred as
a result of the presence of asbestos, asbestos-containing, lead based, or toxic materials at the work site.
6.2 Change Orders - If Jurin Roofing Services, Inc. is requested by general contractor, prime contractor or
owner to perform extra or changed work that was not part of Jurin Roofing Services, Inc.'s original
scope of work, general contractor, prime contractor or owner will provide reasonable compensation to
Jurin Roofing Services, Inc. for said work. General contractor, prime contractor or owner shall not
give orders to Jurin Roofing Services, Inc. for the work that is required to be performed at that time
and then refuse to make payment on the grounds that a Change Order was not executed at the time the
work was performed or the general contractor, prime contractor or owner's representative was not
authorized to order the change. General contractor, prime contractor, owner and Jurin Roofing
Services, Inc. recognize that in order for construction projects to proceed in a timely and efficient
manner, changes in the original specifications frequently are made prior to execution of formal
Change Order documents. The parties agree to work in good faith with each other so that Jurin
Roofing Services, Inc. does not proceed with changed work without authorization and Jurin Roofing
Services, Inc. receives fair compensation for authorized change work.
PRJ#2290: Townview Center-TJ MAXX—Penthouse Removal Page 2 of 5
Corporate Office and Remittance:
:�! � 2150 Rosedale Road, Quakertown, PA 18951
PA Contr.#PA019043
Florida Branch Office:
29716 US Highway 27, Dundee, FL 33838
Florida Contr #CCC1325665 FL Business Lic. #23289
Jurin Roofing Services, Inc. Tel. (800)710-7525 Fax(215)536-2661 www.jurinroofing.com
6. Contract Provisions and Exclusions (con�)
6.3 Dispute Resolution - In the event of a dispute between the parties hereto, the parties shall seek to
mediate the dispute. If inediation is not successful, arbitration shall be promptly conducted. Both
mediation and arbitration shall be held in the county where the Project is located.
6.4 Electrical Conduit- Owner represents there is no electrical conduit embedded within the existing
roofing to be removed or attached directly to the underside or topside of the roof deck upon which
contractor will be installing the new roof. Owner will indemnify Jurin Roofing Services, Inc. from
any personal injury, damage, claim or expense because of the presence of electrical conduit, shall
render the conduit harmless so as to avoid injury to Jurin Roofing Services, Inc. personnel, and shall
compensate Jurin Roofing Services Inc. for additional time and expense resulting from the presence of
such materials.
6.5 Fumes and Emissions - Customer acknowledges that roofing involves the use of solvent based materials.
Odors and emissions from roofing products will be released and noise will be generated as part of the
roofing operations to be performed by Jurin Roofing Services, Inc. Customer shall be responsible for
interior air quality, including controlling mechanical equipment, HVAC units, intake vents, wall vents,
windows, doors and other openings to prevent fumes and odors from entering the building. Customer
is aware that roofing products emit fumes, vapors and odors during application process. Customer
shall indemnify and hold harmless Jurin Roofing Services, Inc. from claims from third parties relating
to fumes and odors that are emitted during the normal roofing process.
6.6 Indemnify and Hold Harmless Clause - Jurin Roofing Services, Inc. agrees to indemnify and hold
harmless the Owner from all claims, damages, losses and expenses for personal injury, including death
and property damage, to the extent caused by a negligent act or omission by Jurin Roofing Services,
Inc. or someone for whose acts Jurin Roofing Services, Inc. is responsible. Jurin Roofing Services,
Inc. is not obligated to provide indemnity for damages, losses, claims or expenses to the extent due to
the negligence or fault of indemnities ar others for whose conduct Jurin Roofing Services, Inc. is not
responsible. Similarly, Owner shall indemnify and hold harmless Jurin Roofing Services, Inc. from all
claims for bodily injury, including death or other damages, to the extent due to the negligence of
Owner or the fault of its agents, representatives or employees. Owner agrees to hold harmless and
indemnify Jurin Roofing Services, Inc. from any and all future construction defect claims.
, 6.7 Mold growth exclusion - Jurin Roofing Services, Inc. and Owner are committed to acting promptly so
that roof leaks are not a source of potential interior mold growth. Owner will make periodic
inspections for signs of water intrusion and act promptly, including notice to Jurin Roofing Services,
Inc., if Owner believes there are roof leaks, to correct the condition. Upon receiving notice Jurin
Roofing Services, Inc. will make repairs promptly so that water entry through the roofing installed by
Jurin Roofing Services, Inc. is not a source of moisture. Jurin Roofing Services, Inc. is not
responsible for indoor air quality. Owner shall hold harmless and indemnify Jurin Roofing Services,
Inc. from claims due to poor indoor air quality and resulting from a failure by Owner to maintain the
interior of the building in a manner to avoid growth of mold.
6.8 Customer acknowledges that tear-off of existing roofing materials and re-roofing of an existing building
may cause disturbance, dust or debris to fall into the interior. Customer agrees to remove or protect
property directly below the roof in order to minimize potential interior damage. Jurin Roofing
Services, Inc. shall not be responsible for disturbance, damage, and cleanup or loss of use or loss to
PRJ#2290: Townview Center-TJ MAXX—Penthouse Removal Page 3 of 5
Corporate Office and Remittance:
.. 2150 Rosedale Road, Quakertown, PA 18951
PA Contr.#PA019043
Florida Branch Office:
29716 US Highway 27, Dundee, FL 33838
Florida Contr. #CCC1325665 FL Business Lic. #23289
Jurin Roofing ServiCes, InC. Tel.(800)710-7525 Fax(215)536-2661 www.jurinroofing.com
6. Contract Provisions and Exclusions (conz)
interior property that Customer did not remove or protect prior to commencement and during the
course of roofing tear-off and re-roofing operations. Customer shall notify tenants and building
occupants of re-roofing and the need to provide protection underneath areas being re-roofed.
Customer agrees to hold Jurin Roofing Services, Inc. harmless from claims of tenants and occupants
who were not so notified and did not provide protection.
6.9 Jurin Roofing Services, Inc. shall furnish the labor and materials necessary to perform the work
described herein or in the referenced contract documents. Jurin Roofing Services, Inc. is not a
licensed architect or engineer and does not provide architectural, engineering or consulting services. It
is the owner's responsibility to retain a licensed architect or engineer to determine structural integrity
and proper design, including that the design is in compliance with applicable ordinances, codes and
regulations. If plans, specifications or other design documents have been furnished to Jurin Roofing
Services, Inc. customer warrants they are sufficient and conform to all applicable laws and building
codes. Jurin Roofing Services, Inc. is not responsible for any loss, damage or expense due to defects
of plans or specifications or building code violations unless such damage results from a deviation by
Jurin Roofing Services, Inc. from the contract documents. Customer warrants all structures to be in
sound condition capable of withstanding normal activities of roofing construction equipment and
operations and the work that is to be performed. Jurin Roofing Services, Inc. is not responsible for
location of roof drains, adequacy of drainage or ponding on the roof.
6.10 This proposal is being submitted based upon standard roofing practices with the intention of providing
long-term moisture protection. No consideration has been given to local building code requirements.
Change to the specifications may be required in order to comply with local codes. Any changes to this
scope of work in order to comply with code requirements will be considered a change order to the
project.
6.11 Owner warrants that the structures on which Jurin Roofing Services, Inc. is to work are in sound
condition and capable of withstanding normal activities of roofing construction equipment and
operations. Owner represents that there is no electrical conduit embedded in the existing roofing or
attached directly to the underside or topside of the roof deck upon which Jurin Roofing Services, Inc.
will be installing the new roof. Owner will indemnify Jurin Roofing Services, Inc. from any personal
injury, damage, claim or expense due to unsafe structural conditions and the presence of electrical
conduit, shall render the conduit harmless so as to avoid injury to Jurin Roofing Services'personnel,
and shall compensate Jurin Roofing Services, Inc. for additional time and expense resulting from the
presence of such materials and unsafe structures.
6.12 Design Professional is responsible to design the work to be in compliance with applicable codes and
regulations and to specify or show the work that is to be performed. Jurin Roofing Services, Inc. is
not responsible for design, including calculation or verification of wind load design. To the extent
minimum wind loads or pressures are required; Jurin Roofing Service, Inc.'s bid is based solely on
manufacture's printed test results. Jurin Roofing Services, Inc. is not responsible for the construction
of structural sufficiency of the roof deck or other building components not constructed by Jurin
Roofing Services, Inc.
PRJ#2290: Townview Center-TJ MAXX—Penthouse Removal Page 4 of 5
Corporate Office and Remittance:
�. � 2150 Rosedale Road, Quakertown, PA 18951
PA Contr.#PA019043
Florida Branch Office:
29716 US Highway 27, Dundee, FL 33838
Florida Contr. #CCC1325665 FL Business Lic. #23289
Jurin Roofing ServlCes, InC. Tel (800)710-7525 Fax(215)536-2661 www jurinroofing.com
6. Contract Provisions and Exclusions (con�)
6.13 Building Permit Exclusion - The cost of the building permit, if required, is not included in the proposed
price as noted. Jurin Roofing Services, Inc. will pull the permit on behalf of the owner. The cost of
the building permit plus a handling fee of 10%will be added to the cost of the project if a building
permit is required. This will be handled as a change order.
6.14 Jurin Roofing Services, Inc. is not responsible for leakage through the existing roof or other portions of
the building that have not yet been reroofed by Jurin Roofing Services, Inc. Jurin Roofing Services,
Inc. is not responsible for damages or leaks due to existing conditions or existing sources of leakage
simply because Jurin Roofing Services, Inc. started work on the building.
Notes: Unless stated otherwise on the face of this proposal, Customer shall pay the contract price plus any
additional charges for changed or extra work within ten (10) days of substantial completion of the
Work. If completion of the Work extends beyond one month, Customer shall make monthly progress
payments to the Contractor by or before the fifth(Sth) day of each month for the value of Work
completed during the preceding month, plus the value of materials suitably store for the project. All
sums not paid when due shall earn interest at the rate of 1 1/12 percent per month. Contractor shall be
entitled to recover from Customer all costs of collection, including attorney's fees, resulting from
Customer's failure to make proper payment when due.
Statement of Quality - All material is guaranteed to be the same as specified. All work is done in
accordance with accepted roofing practices as determined by the NRCA. All extra work will be done
through change orders and will be an extra cost above and beyond the stated price. All agreements are
contingent upon delays beyond our control. Owner to carry all necessary fire, tornado, and other
insurance. Our workers are fully covered by workman's compensation insurance.
This proposal may be withdrawn if not accepted within 30 days of submission.
Mr. Christophor Jurin
President
Jurin Roofing Services,Inc
I� accept the above proposal on 20
Authorized Signature
PRJ#2290: Townview Center-TJ MAXX—Penthouse Removal Page 5 of 5
, � � 1 � I
� CARLISLE'S
S�JRE�WELD� REINFORCED
� � TPO MEMBRANE
Carlisle's Sure-Weld tan and white TPO membrane can contribute toward
LEED�(Leadership in Energy and Environmer�al Design)credits.Tan
and white Sure-Weld are ENERGY STAR�*-qualified and California Title
24 compliant.
Features and Benefits
• Outstanding puncture resistance
• Chlorine-free with no halogenated flame retardants
.�
• Plasticizer-free;does not contain liquid or polymeric plasticizers
• Excellent low temperature impact resistance
• Excellent chemical resistance to acids,bases and restaurant
exhaust emissions
Overview • Exceptional resistance to heat,solar UV,ozone and oxidation
Carlisle Sure-Weld membrane is a premium heat-weldable single-ply • Low water vapor permeance and water absorption
thermoplastic polyolefin(TPO)sheet designed for new roof construction
and re-roofing applications.Sure-Weld High Slope(HS)membrane is ' Hot-melt extrusion processed for complete scrim encapsulation
formulated with additional flame retardant(compared to Standartl)for • Warp-knitted fabric(not woven)for smooth surtace and greater
higher-slope fire code approvals.Sure-Weld EXTRA is 80-mils-thick for thickness over scrim
significantly higher strength and weatherability.
• Sure-Weld is 100%recyclable
Carlisle's Sure-Weld TPO membrane is based on advanced (refer to Carlisle's Recyclability Statement)
polymerization technology that combines the flexibility of ethylene-
propylene(EP)rubber with the heat weldability of polypropylene.All Installation
Sure-Weld TPO membranes include OctaGuard XTT^^,an industry-
leading,state-of-the-art weathering package.OctaGuard XT technology Sure-Weld Roofing Systems are quick to install as minimal labor and
enables Sure-Weld TPO to withstand extreme weatherability testing few components are required.The systems may be installed utilizing
intended to simulate exposure to sever climates. labor-saving devices that make sheet welding fast,clean,consistent
and easy to learn,while reducing strain on the roofing technician.
Physical properties of the membrane are enhanced by a strong
polyester fabric that is encapsulated between the TPO-based top and The Carlisle Mechanically Fastened Roof System installation starts
bottom plies.The combination of the fabric and TPO plies provides with the insulation fastened with a minimum of 5 fasteners per 4
Sure-Weld reinforced membranes with high breaking strength,tearing by 8 ft.board.The Sure-Weld reinforced membrane is mechanically
strength and puncture resistance.The relatively smooth surtace of fastened to the deck using HP-XT"^Fasteners and Piranha PlatesT^^
Sure-Weld membrane produces a total surtace fusion weld that creates or HP-XTRA Fasteners and Piranha XTRA Plates.Adjoining sheets of
a consistent,watertight monolithic roof assembly.The membrane is Sure-Weld membrane are overlapped over the fasteners and plates and
environmentally friendly and safe to install. joined together with a minimum 1'/z-inch-(4 cm)wide hot-air weld.
Sure-Weld Stantlard and HS products are available in highly reflective The Carlisle Fully Adhered Roofing System application begins
white,tan and gray,in both 45-mil and 60-mil thicknesses.Sure-Weld with the insulation fastened at the required density(max.1 every 2
EXTRA(including HS)is available in 80-mil thickness,in white,gray sq ft)necessary to resist the appropriate wind load.The substrate
and tan.Sixteen special colors are also available(see Carlisle's TPO and membrane are coated with an appropriate Sure-Weld Bonding
Color Palette brochure).Available widths are 4-,5-and 6-ft perimeter Adhesive and the membrane is rolled into place.
sheets and 8-,10-and 12-ft field sheets. * CONSULT CARLISLE SPECIFICATIONS FOR COMPLETE
INSTALLATION INFORMATION.
Investing in Roofing Solutions for 50 Years
500-479-6832• PO Box 7000• Carlisle,PA 17013 • Fax:717-245-7053•www.carlislesyntec.com � � —
Carlisle SynTec
' ll � � �
� CARLISLE'S
S�IRE�WELD REINFORCED
� � TPO MEMBRANE
Precautions 4. Use proper stacking procedures to ensure sufficient stability
of the rolls.
1. Sunglasses that filter out ultraviolet light are strongly
recommended as tan and white surfaces are highly reflective. 5. Exercise caution when walking on wet membrane.Membranes
Roofing technicians should dress appropriately antl wear may be slippery when wet.
sunscreen to protect skin. 6. Store Sure-Weld membrane in the original undisturbed plastic
2. Surtaces may become slippery due to frost and ice buildup. wrap in a cool,shaded area and cover with light-colored,
Exercise caution during cold conditions to prevent falls. breathable,waterproof tarpaulins.Sure-Weld membrane that has
been exposed to the weather must be prepared with Weathered
3. Care must be exercised when working close to a roof edge when Membrane Cleaner prior to hot-air welding.
surrounding area is snow-covered as the roof edge may not be
clearly visible.
� ' • � • � ' 1 �
„ ,. ,, �_ ..
.., ., ,
, , ; , : �_ . ��
�.,� , „
.. .. ,�,„ . �= .,:.- ,. �r �` v, ,�'��
., _:. __ ,, , „ �,. .., ' �.
_ ,._.:-,. _„ ,-_- . - "^, , ..:„ ,.,t,., � , H... ,. ._� :,
Tdaranoe on roomir�ei tlNduiess,% +15,-10 s 10 s 10 s 1p
ASTMl1751 test lnetlwd
Tl�Cicness arer sc�im,in.(mm) OA�5+� 0.018 typ O.OY!typ 0.034 typ
ASTM�18878 optkel methDd, (0.381) (0.45� (0.6101 {0.864) •
avereye�Df 3 a[�s
Breekin0 srenydt,�f(kN) 220(978 N) ,226{1.0)min 250�9.1)aNn $50�1.8)nfin
AS'fM D751 pr�7netlxtd t►�n 32011.4)ty� S8l1(16)tYP 425(1�?t�
8ony�dion broedc afi.�eM�iL 15 mN► 15 mk� 15 min 15 min
ASTM tl751 gr�ntetlMDd 25#yP 2fi tyD 25 h�p
Teari�y�lp�.ibf(N� 55(245)min 85 j245)min 85(�ai5�m� 55{�)�pin
asnA ors��►oc.e a�.X e�,. ��ts�sa�p isQ�s�s��rP �so is�e��ro
er�ca�,e�e�,t,�t°c� -�o t-�oj max -�o{-�wy�ax .4o t-�o�mex «w�.�oj„rex '
AS7M 02137 -50(-�81 h�P b0 l-46)tyP -fi0(-�{6)tyP
L:iMar tlimOlqidml ChM1qe.9G t 1 11�x s 1 Imeu *1 a�a�c *1 m9x
AS'f#1 D1204,8 fiours si 158°F -0.2 hiP -03 tyP -0.2 hiP
Qmrk�Ce.nDCradcs 7�f PASS PASS PASS PA'SS
AST1A D]149.,1�DP�►,1$8 Ms
wahr�De�a+r�,m��. t SA mox t 3.0 rt�x . , t 3'9�x �_.^ �_.,.-s 3.�maic ��
ASt'Mi�li1�OP wfaoe+� 2.0 h�V ZDtYP 2.D t4A
186 Mur6�if+8°F w86pr
Fecto�r aesm atronpn���+(kN�m1 ss{2so)a� �t29o)m�n 86 t�)� Ss(290)a�n
ASTM 07514�ab method
peld a�+atreiqtli�N�f/Yf ticN/m) No roqulrement 25(4.4f min 25{4.4)min �40(7.0)� �
ASTIid 01876 teSteli&1 P� 50 i8.8)tYP 80(1Q5)tf'D 70(12 3)'!YD
W�'�Aern�.Perms No ropukennent �.i0 max 0.10 maa� fl.10 msx
AS7M�6 Droc.B OAS ifrP 0 Q5 h9► 0.45 fyR
Purwhire ree�tance,Ibf(kN) No reVuire�nent 280{1.1)min 800{t.8)� �it.8)min
FiM/�1C.mOtliod 2091 325(1.4I�YP 850(1.5)hiP 450{2.0)h�D
(see�bma►tai sectlonl
Propertbs t�ter heat apNq
ASTM Db73,82 weeks�240°F
Breakle0 atrengtli,%retafned 90 min 90 mM 90 min 90 min
Elor�padan rei�.,96 retair�ed 90 min 90 min 90 mM 90 min
Tearinp Strength,96 retained 60 m� 60 m� 60 min 60 mfn
WeigM d�ange,9f, s 1.0 max s 7.0 max *1.0 max s 1.0 max
TYa�We�9Ms 0.231b/ft�(1.1 kg/m2) 0.29(1.4) 0.40(2.0)
* Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product.
This data and information is intended as a guide and does not reflect the specification range for any particular property of this product.
Investing in Roofing Solutions for 50 Years
800-479-6832• P 0 Box 7000 •Carlisle,PA 17013• Fax:717-245-7053•www.carlislesyntec.com � � -
Carlisle SynTec
� , � � ' I I
� CARLISLE'S
S�IRE�WELD REINFORCED
� � TPO MEMBRANE
Extreme Testing For Severe Climates
ASTM Standard D6878 is the material specification for Thermoplastic Polyolefin Basetl Sheet Roofing. It covers material property requirements for
TPO roof sheet and includes initial and aged properties after heat and xenon-arc exposure.As stated in the scope of the standard, "the tests and
property limits used to characterize the sheet are values intended to ensure minimum quality for the intended purpose."Carlisle's goal is to produce
TPO that ensures maximum pertormance for the intended purpose of roofing membranes.Maximum performance requires the membrane to far
exceed the requirements of ASTM D6878.For severe climates like Miami,FL and Phoenix,AZ,EXTREME testing is required.
Heat Aging accelerates the oxidation rate that roughly doubles for exposure.The acid fog accelerates acid etching that may occur from
each 10°C(18°F)increase in roof inembrane temperature. Oxidation acid rain if the roof inembrane is not resistant to acidic conditions.
(reaction with oxygen)is one of the primary chemical degradation • ASTM requirement—none
mechanisms of roofing materials.
• Carlisle EXTREME test*•
� � � �
,-: ,,{,.,,,, ,;�,� ,,f.,. .. � • 10 days heat aging at 240°F(116°C)followed by
` �"�'' � - • 5 days water immersion at 158°F(70°C)or with another
ASiM TEST ?40°F 32 w90k8 x b2 weeks
specimen set
�r t� 27�F ��A 13� • 5 eight-hour cycles in Kesternich sulfur dioxide chamber
(sulfurous acid fog)followed by
• Test specimen is 1"by 4"piece of 45-mil membrane unbacked, • 5040 kJ/m2(2000 hrs at 0.70 W/m2 irradiance)xenon-arc
placed in circulating hot-air oven. exposure
*Test specimen is 2.75"by 5.5"piece of inembrane with edges sealed.
• Criterion—no visible cracks after bending aged test specimen
around 0.25"-diameter mandrel. *Criterion—after 3 complete cycles,test specimens shall remain
flexible and not have any cracking untler 10x magnification while
Xenon-Arc exposes the membrane samples to the combined effect wrapped around a 3"-diameter mandrel.
of ultraviolet,visible and infrared radiation as well as ozone,heat and
water spray,to greatly accelerate the effects of outdoor weathering.
The radiation dose is measured in kilojoules per square meter(kJ/
m2)at 340 nm machine UV wavelength.The irradiance power of the
xenon-arc lamp is measured in Watts per square meter(W/m2).
� � �
� ,� ,�,y�v���� ,, . , r, a_�,a m s,_=K.� tr"_,�--,,� —
ASTM 1EST �T 46-MML e0-�All !0-�
kJ/m=at 3d0 nm 10.a80 17,640 20,960 27,720
• Test specimen is 2.75"by 5.5"piece of inembrane,unbacketl,
weathering side facing arc lamp.
• Criterion—no visible cracks viewed under 10x magnification
while wrapped around 3"-diameter mandrel.
Environmeirtal Cycling subjects the membrane to repeated cycles
of heat aging,hot-water immersion or acid fog followed by xenon-arc
Investing in Boofinq So/utions for 50 Years
800-479-6832• PO Box 7000• Carlisle,PA 17013 • Fax:717-245-7053•www.carlislesyntec.com � � '
Carlisle SynTec
, � � 1 I I
� CARLISLE'S
SIJRE�WELD REINFORCED
� � TPO MEMBRANE
Supplementai Approvals, Statements 3. Sure-Weld TPO membranes conform to requirements of the
and Characteristics: U.S.E.P.A.TOxic Leachate Test(40 CFR part 136)performed by
an independent analytical laboratory.
1 Sure-Weld TPO meets or exceeds the requirements of ASTM
D6878 Standard Specification for Thermoplastic Polyolefin Based 4. Sure-Weld reinforced TPO was tested for dynamic puncture
Sheet Roofing. resistance per ASTM D5635-04 using the most recently modified
impact head.45-mil was watertight after an impact energy of
2. Radiative Properties for ENERGY STAR,Cool Roof Rating Council 1 p,5 J(9.2 ft-Ib�and 60-mil was watertight after 22.5 J(16.6
(CRRC)and LEED. ft-Ib�.Both 72-mil and 80-mil EXTRA products were watertight
after an impact energy of 30.0 J(22.1 ft-Ib�.
ElI�YSiAN S41et3pechvm 0.87 U.68 WA
ir�ial�ralpc�rtce RBii�CtDn�tlfier
H�i'Y ST�IR iN� SoMr SpeCbtNn 0.83 0.64 N/A
ader re� RefleCtanete�
aRer 3 f� i�r deanio0)
i�qi6 kd681 AS'fM C1549 0.79 0.71 0.46
aoNr rolleCtar�
t�RC soler rotl�mnce AST#A Cy549 0.70 0.84 0.43
aikr 8 Years 1an�ned)
t�i1C h�itlal ASTIYI C1371 0.90 0.86 0.90
tlfelrilal±e�dttance
(�HG titer�led ASTM Ct371 0.86 0.87 0.88
amttter+oe erter 3 Y� i�dl
t�tl�ennai�duae ASTM E408 0.95 0.� 0.95
SRI 15aler�NidBIQ AS�M�1980 170 86 55
Solar Reflectance Index(SRI)is calculated per ASTM E1980.The SRI is
a measure of the roof's ability to reject solar heat,as shown by a small
temperature rise.It is defined so that a standard black(reflectance
0.05,emittance 0.90)is 0 and a standard white(reflectance 0.80,
emittance 0.90)is 100.Materials with the highest SRI values are the
coolest choices for roafing.Due to the way SRI is defined,particularly
hot materials can even take slightly negative values and particularly
cool materials can even exceed 100.
� �
Pre-carreNru�Rbcyded Coldetd 10�6
Post-co�ltmer Recyi�ed Caneni 0!6
MenufaCi�xNtp LacedOn SenStC�.MS
Tooele,UT
Sder RAfleCtenCB I�ex 71�
Investing in Boofing So/utions for 50 Years � �
800-479-6832• P0 Box 7000 • Carlisle,PA 17013• Fax:717-245-7053•www.carlislesyntec.com '
Carlisle,Sure-Weld,Octaguard X7,Piranha Plates and HP-X are trademarks of CaAisle.
ENERGY STAR is a registered trademark awned by the U.S.Govemment.LEED is a trademark of the U.S.Green Building Cauncil. ria��l$�e.SynTeC
'ENERGY STAR qualification is onty valid in the U.S
REPRINT CODE:600515-"Sure-Weld Reinforced TPO Membrane Product Data SheeY'-021812�2012 Carlisle.
� � 11 � , .
Tpo �o pvc �oW-voc
ADHESIVES AND SEALANTS
Increased governmental regulations,combined with the low-VOC requirements of LEED�and other environmentally conscious programs,have caused a shift
in the construction community towards the use of low-VOC products.The roofing industry is certainly not excluded from these changes.To qualify for low-VOC
status,an adhesive must have a VOC content of 250 grams/liter or less,and a sealant must have a VOC content of 450 grams/liter or less.However,certain
products are excluded from the VOC content requirement based on packaging size,vapor pressure or other reasons.
Carlisle is leading the way in meeting the growing number of VOC regulations.Carlisle is continually developing products that meet the low-VOC requirements of
new governmental regulations and green building codes.The following products meet the current limitations of known regulations as of the publish date.
Low-VOC Bonding Low-VOC Bonding
Adhesive �`�`°� � Adhesive 1168 -
� �� ,� _
is a high-strength solvent-based is a high-strength solvent-based
contact adhesive that allows bonding ' contact adhesive that allows bonding
of Carlisle TPO membranes to various " of Carlisle TPO membranes to various
porous and non-porous substrates.tt porous and non-porous substrates. ���
is specially formulated using a blend Low-VOC Bonding Adhesive 1168 is �'�•- 6��
of VOC-exempt and non-exempt compliant for use in all CA counties. --
solvents that are ideal for use where °°�'
low-VOC products are required.
Low-VOC Bonding Adhesive 1168 is
available for use in Califomia.
'Proper mixing is required
i 1 : � � � + � i 1 : � � � � � �:
�
..
�M A�.r, .,�
�,r.
voc co�n xso�uce�� % voc ca�a zso oramsn�r�aX
Pe�k�N�O 5-pallon paii Packayle0 5-OaNOn pail
Sl�elf Ufe t year Sheif LHB 1 year
Aqua Base 120 Low-VOC PVC
is a unique,semi-pressure-sensitive, - `�`�°'""��" B011dlllg Adh@SIV@
water-based bonding adhesive for U Carlisle's Low-VOC PVC Bonding
certain FleeceBACK�,TPO and PVC Adhesive is a high-strength
membranes offering superior peel ,,,.,.,` solvent-based contact adhesive that
strengths without VOCs or strong odors. ;^� allows bonding of PVC and KEE-
Aqua Base is installed using a one- enhanced PVC membranes to various
sided wet lay-in application for porous and non-porous substrates.
FleeceBACK membranes.Aqua Base This product is also approved for
120 can also be utilized as a contact use in CA.
adhesive for TPO and PVC membranes.Coverage rate is 100 sq.ft.(9 sq.
meters)per gallon and it is packaged in 5-gallon pails.
' ' � � 1 : i � � � �
�'1/1C�.< , ,� .� ,,,• �a�;: , .,
. .. ,, -, , ,. -
, ,�;��,. �� ��".a =
VOC CoMent 8 grams/ifter 'VOC 6o�eM 250 grams/Ilter max
Packaging 5-gallon pail Pack�i� 5-gallon pafl
Shelf Llfe 1 year Shelf Llfe i year
800-479-6832•P.0 Box 7000•Carlisle,PA 17013• Fax:717-245-7053•www.carlislesyntec.com �
SYNTEC SYSTEMS
• , � � 1 I I
TPO aN� PVC Low-VO C
ADHESIVES AND SEALANTS
Low-VOC TPO Primer Weathered
is a low-solids,clear,solvent-based ti,� � Membrane Cleaner
p r i m e r u s e d t o p r e p a r e T P O �T p p is use d to c lean b ot h new an d
e,:-=_-
mem brane for a d hesion to pressure- �-==� S in-service membrane.It helps to
sensitive TPO coverstrip and RUSS �"_=_� � � loosen and remove dirt and other � °
where VOC regulations or restrictions e_--=� c �- a.'�"'""'..
contaminants from the surface of
�
exist. = _=;� `— the membrane and leaves a suitable �
��-= surtace for primer application or l�j
welding.
'Note:This product is not compliant in CA.
� 1 ' 1 ' •� � ' 1
,, ., .
..A, ,� . �4.; ;�x.,, �,, . ,
.. . .. �.. �.,.r�� �,�,.,. . ;, .r
„ , , .
VOC Content 250 qrams/�ter max VOC CordeM Exempt based on vapor presaure'
padca9�og (6)1-gaNa�can Packagin9 5-qallon closed-top pail or
Shelf ufe t year in unopened can (2)�-O�Ion cbaed-MA P�
Shelf Life N/A
� �
' . . �"; -., - �..��;_ ,��.._.a k�Y+
,_. ., .x,:.
VOC CoMeM VOC Exempt
Packa�ng 5-pallon can
Shelf Lffe N/A
SATTM TPO Membrane
a heat-weldable single-ply Clear Cut Edge �
thermoplastic polyolefin(fP0) Sealant
sheet designed for fully adhered 'j
applications.The 100%solids,hot- , a medium solids,free-flowing,
melt pressure-sensitive adhesive polymeric material designed to be
eliminates VOC and odor concerns � used for sealing cut edges of Carlisle's
typically associated with fully adhered TPO or PVC membranes.Qualifies
systems. for small quantity exemption in most
areas.
� 1 � � � 1
,; y�'°�'':
YOC ConteM nare VOC CaMeM Exempt for small quantity
Packeging 10'x 100',50' P�kaping (8)16-oz.batdes/ctn
Shelf IJfe t year Shetf LMe 1 y�r
� �
�„ , . . ._. ,
� � s ,,,...�m �� , <w
VOC CoMeM Exempt for small quantity
Packagki9 (12)16-oz.battles/ctn
Shelf Life i yeer
800-479-6832•P.0 Box 7000• Carlisle,PA 17013• Fax:717-245-7053•www.carlislesyntec.com �
SYNTEC SYSTEMS
II �
II . ' ' ' I I
Tpo �o pvc �oW-voc
ADHESIVES AND SEALANTS
Universal Single-Ply ,,�a ._..s..;;, White One-Part
Sealant �� Pourable Sealer -
is a 100�o-solids,solvent-free,one- £G,.:
part,polyether sealant that provides e`� e` ia single-componeM,moisture- � , _ ,
a weathertight seal to a variety of curing,elastomeric polyether «���^ _
sealant that is compatible with ��LL--= =.�;:=
building substrates and can be used all Carlisle roofing systems and � ,�,
�, .;�'' �
as a termination bar sealant for provides a watertight seal around
Carlisle's EPDM,TPO and PVC hard-to-flash penetrations.
roofing systems.
� � � 1 � �
s°°' _ ��re, � w,.�
... �,o ; ,,;::. ,.p . ._..;. rr�,; „ ;r,,., ,.:�4,� _ ,._ ;_„
VOC Content 0 grams/Ifter VOC ConteM 0 gramsRfter
PaCkaging 24 cartridges,10.1 fl.oz.each Peckaging (4)Ye-gal pouches per W�cket
Shelf LHe 7 year in unopened container Shelf LHe 18 months
Water Cut-Off Mastic iiui�� CAV-GRIpTM
is a one-component,low-viscosity, is a Low-VOC,methylene chloride-
self-wetting butyl blend mastic used with free,multi-purpose contact adhesive/
roofing and waterproofing systems,and primer recommended for enhancing
when a membrane is being terminated the bond of Carlisle's 725TR.
using a compression-type seal. CAV-GRIP is also used as a primer
for unweathered asphalt.
1 ,
�.
VOC Content 250 qra�/�ter max VOC CoMent 71�ams/liter
����9 25 4�es�carton Padcaping 40-Ib aeroaol cylinder
Shelf Lfle 1 year in unopened container Shelf Llfe 1 year in unopened coMainer
800-479-6832•PO Box 7000•Carlisle,PA 17013• Fax:717-245-7053•www.carlislesyntec.com �
SYNTEC SYSTEMS
' � � 11 � , �
Tpo �o pvc �oW-vo c
ADNESIVES AIVD SEALANT
S
FASTTM Adhesive Flexible FAST
is a low-rise,iwo-component, Adhesive
insulating polyurethane adhesive.tt is a low-rise,two-component,
can be used to adhere a varieiy of insulating and energy-absorbing
insulations and Carlisle's FleeceBACK polyurethane adhesive with 150�0
membranes,and is applied in full elongation to better handle building
spray or beads. movement and roof system expansion
and contraction.
� � , � , , �
��� � ,�, �. - �.� �. _�
YOC Cor�aM 0 grams/li[er � VOC Cor�ent .. , 0 prams . k q§ ,
/titer
Packeging 15-and 50-gaWon drums,Bag-in-a-BOx end Dual Peckaging 15-and 50-gallon drums(Part A and 8)
Cartridges(Part A and B) g�ff�e 1 year(Part A and B)
Sheif IJfe 1 year(Part A and B)
Cold Applied � CCW-702LV Primer _
Adh@SIV@ ��":_,:�,:;.^,;-:;�.._r.�.,,�, is a quick-drying,solvent-based,
is an asphalt-modified polyether, _ high-tack adhesive/primer specifically
one-sided,wet lay-in adhesive designed to promote maximum
designed to adhere to AFX membrane adhesion of Carlisle's 725TR Air
and Carlisle's modified base sheet. and Vapor Barrier
� i � � � •� � � �
VOC CoMent 32 grams/Nte� VOC ConteM 250 pramaAlter m8x
��°g 5"9aHa�Pe�� P�kaO��g 5-gaNOn pall
Shelf LHe 9 mordhs Shetf Lxe 1
yeer In unoper�ed coMalner
*Typical properties and characteristics are based on samples tested
and are not guaranteed for all samples of this product.This data and
information is intended as a guide and does not reflect the specification
range for any particular property of this product.
800-479-6832• P.0 Box 7000•Carlisle,PA 17013•Fax:717-245-7053•www.carlislesyntec.com �
Carlisle,SAT,Sure-Weld,Sure-Seal,Sure-Whlte,Sure-TOUgh,FleeceBACK,FAT,FAST,SecurTAPE,CAV-GRIP a�In-Seam SealaM are tretlemarks of Carlisle. syivTec sYSTeMs
LEED is a registe2d t�ademark of the U.S.Green Buiftling Council.
REPRINT CODE:600262-7Po and PVC Low-VOC Atlhesives and Sealants Product Data Sheet-08.23.12 m 2012 Carlisle.
� • DATE(MMIDD/YYY1�
ACOR� CERTIFICATE OF LIABILITY INSURANCE 03/05/2013
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED
REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER.
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to
the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the
certificate holder in lieu of such endorsement s .
PRODUCER
NAME:
Michael E.Santarsiero PHONE , g14 412-0559 aC Na; 914 381-1134
c/o Kevin Spero Whitelaw,Inc. E.�,�Ai�
500 Mamaroneck Ave. nooreess:
Harrison,NY 10528 INSURER S AFFORDING COVERAGE NAIC#
iNSUrtertn: Zurich-American Insurance Company 16535
INSURED INSURER B.
DSK Group,Inc.et al Alt.Emp:C&C ELECTRICAL CONTRACTORS INC �NSURER C:
dba:C&C ELECTRIC of TAMPA BAY,INC
6715 W Grover Cleveland Blvd INSURER D:
Homosassa,FL 34446 INSURER E:
INSURER F.
COVERAGES CERTIFICATE NUMBER:12FL076799792 REVISION NUMBER:
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
INSR TypE OF INSURANCE �DL SUBR POLICY EFF POLICY EXP LIMITS
lTR POLICY NUMBER MM/DD MMIDD/YYYY
GENERAL LIABILITY EACH OCCURRENCE $
COMMERCIAL GENERAL LIABILIN DAMA E T RENTED
PREMI ES E cc rrence $
CLAIMS-MADE � OCCUR MED EXP(My one person) $
PERSONAL 8 ADV INJURY $
GENERALAGGREGATE $
GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $
POLICY PR� LOC $
AUTOMOBILE LIABILITY M IN D IN LE LIMI
Ea accident
ANY AUTO BODILY INJURY(Per person) $
ALL OWNED SCHEDULED BODILY INJURY(Per accident) $
AUTOS AUTOS
NON-0WNED PPe�a c dentDAMAGE $
HIRED AUTOS AUTOS
$
UMBRELLA LIAB OCCUR EACH OCCURRENCE $
EXCESS LIAB CLAIMS-MADE AGGREGATE $
DED RETENTION$ $
WORKERS COMPENSATION X WC STATU- OTH-
AND EMPLOYERS'LIABILITY Y 1 N �'
ANY PROPRIETOR/PARTNERlEXECUTIVE E.L.EACH ACCIDENT $ 'I,OOO,OOO
A OFFICERlMEMBER EXCLUDED? � N�A WC 40-51-06&05 10/25/2012 10l25/2013
(Mandatory in NH) E.L.DISEASE-EA EMPLOYE $ 1,DU�,UO�
If yes,describe under
DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,000
Location Coverage Period: 10/25/2012 10/25/2013 Client# 35-FL
DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101,Additlonal Remarks Schedule,N more space Is requirod)
Coverage is provided for C&C ELECTRICAL CONTRACTORS�NC dba:C&C
only those employees ELECTRIC of TAMPA BAY,INC
leased to but not 15915 N Florida Ave
subcontractors of: Tampa,FL 33549
CERTIFICATE HOLDER CANCELLATION
CITY OF ZEPHRYHILLS-BLDG.DEPT SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
5335 8TH STREET THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN
ZEPHYRHILLS,FL 33542 ACCORDANCE WITH THE POLICY PROVISIONS.
AUTHORIZED REPRESENTATIVE
i���
�O 1988-2010 ACORD CORPORATION. All rights reserved.
I IIIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII II
20130g2219 IIIIIIIIIII
Permit No. Parcel ID No 35-25-21-0010-08800-0000
NOTICE OF COMMENCEMENT
State of Florida County of Pasco
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following infortnation is provided in this Notice of Commencement:
1 Description of Property Parcel Iden6fication No. 35-25-21-0010-08800-0000
Street Address: TJ MAXX-7326 Gall Blvd.,Zephyrhilis FL 33541 cpt:1523466 ReC: 10.00
O5: 0.00 IT: 0.00
2. General Description of Improvement Roof Replacement 0�5/24/13 B. McBee, Dpty C 1 erk
PqULR S 0'NEIL,Ph D PRSCO CLERK 8 COMPTROLLER
3. Owner Infortnation or Lessee infortnation if the Lessee contracted for the improvement: _�5�24�13 11:g8am 1 Of 1
Townview Retail,LLC OR BK $��� PG 121?
Name
725 Conshohocken State Road Bala Cynwyd pq
Address City State
Interest in Property �Wner
Name of Fee Simple Titleholder
(lf different from Owner listed above)
Address Ciry State
4. Contractor Jurin Roofing Services,Inc.
Name
29716 Highway 27 Dundee FL
Address City State
Contractor's Telephone No. 800-710-7525
5. Surery
Name
Address City State
Amount of Bond: $ Telephone No.
6. Lender
Name
Address Ciry State
Lender's Telephone No.
7 Persons within the State of Florida designated by ihe owner upon whom notices or other documenis may be served as provided by
Section 713.13(1)(a)(7),Florida StatuTes:
Name
Address City State
Telephone Number of Designated Person:
B. In addition to himself,the owner designates of
to receive a copy of the Lienofs Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner
9. Expiration date of Notice of Commencement(the e�iration date may not be before the completion of construction and final payment to the
contractor,but will be one year from the date of recording unless a diffe ht date is specified):
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER F1+ER E EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 7 3, P R 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO Y UR, QPERTY A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE J08 SITE BEFORE THE FIRST I S IQN. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING W l�ECORDING YOUR NOTICE OF COMMENCEMENT
Under penalty of perjury,I declare that I have read the foregoing notice�c e mea�t and thet the fa tated therein are true to the best
of my knowledge and belief. �
STATE OF PENNSYLVANIA i /�
COUNTY OF
Signature of 0 o Lessee,or wnefs or Lessee's Authorized
Officer/Director/Part /Manager
� Authaized Prtson
Signatary's Title/Office
The foregoing instrument was acknowled ed b�efore�m,,Ie this z�daQy of �� 2013,by�p�°,/7 L Pwf S
' as �//Wl J �� `['-� (type of authority,e.g.,officer,trustee,atromey in fact)for
'��n���������� L�� ( f party on be of whom instrument was executed).
Personally Known�QR Produced Identification❑ Notary Signature /1.�--
Type of Identification Produced Name(Print) /�C-)/7c..J/ �1 •�k�c7n
Commonwealth of Penns Ivanl�
NOTARIAL SEAL
wpdata/bcs/noticecommencement_pc053049 RANDI SHENKMAN,NOTARY PUBUC
Lower Merion Township,Montgomery Coue
Commission ires A 8 2015