HomeMy WebLinkAbout13-14079 CITY OF ZEPHYRHILLS
, 5335-8TH STREET q�
� (813)780-0020 �v,9
.�
BUILDING PERMIT
Permit Number: 14079 Address: 39551 MEADOWOOD LP
Permit Type: MECHANICAL ZEPHYRHILLS, FL.
Class of Work: A/C CHANGEOUT Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Seation:
Square Feet: Subdivision: MEADOWOOD ESTATES
Est. Value: Parcel Number: 13-26-21-0140-00000-0760
Improv. Cost: 4,425.00
Date Issued: 4/12/2013 Name: LANCASTER, MAGDALENE HATTIE
Total Fees: 60.00 Address: 39551 MEADOWOOD LP
Amount Paid: 60.00 ZEPHYRHILLS FL 33542
Date Paid: 4/12/2013 Phone: 813-317-7522
Work Desc: A/C CHANGE OUT 2.0 HEAT PUMP
? �
i
DUCTS INS • T -,�-
FINAL U �lJ
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80(2)(c)when extra inspection
trips are necessary due to any one of the following reasons: a)wrong address b)condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d)work not ready for
inspection when called e) permit not posted on job site� plans not at job site g)work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an atto�ney
before recording your notice of commencement."
Complete Plans, Specifcations Must Acxompany Application.All work shall be performed in accordance with
Ci Codes and Ordinances. NO OCCUPANCY BEFO C.O.
�'1 °'`� t
CONTRACTO SIGNATURE PERMIT OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
� � T��
�,:.,���,�,�,�,.a���,.. Date �.��2 7� ,2_ �1�
�.t� , . ., . ,�«� ��::���.;,
./ st0�# I" `�; °S`'.. ,,, . .`i�'�,':,�zi�t;a,.:;,,�
Customer.Name �e�e ��t S -, � ;;��,:r,;;.�, �<• �r�:�Yt�:;r;����
. �p '�e.'y°�u�` ` f�k',�`.xk:';;:',,
StreetAddress ��,,,�.� � ��; c..�,t� , Dealership�Name War.ds�4ir��C�o„, �.t�, �;,,,'.
il ,Y 3,��r..,;n. '..
-� � v;�;:,,
� Dealership Phone# .8���. ..�.-' ����`c�'
� �;�,�:�rc��,:.;�':.:;
City �` 1`�''� �^,���:����; �� :�;A, fl;�v::;�..�:,.,
State p � ,.�.-� Dlr.Admin.Contact � '�a _ �H�, ��,�"�,'?��
ZI �-�`°�' � "j'— �S�-Z � Detail PO# � �':�` ,'' :,�,' '�"�y�� z�;; ^., �
Phone# � � ��.: �,; ,,,:.
Preparation: Professional Services:
x Remove old system and haul away econnect electrical to new unit
Remove old system and leave on the job Provide new electrical for new unit
Level ground and install a new pad na Reconnect existing gas service to the unit
Use existing pad na Install new gas service to the home
Installation: Duct Work:
x Install new system by local code Reconnect to existing ductwork
x Provide equipment owners manuals Install new transitions to the ductwork
x Leave the worksite free of debris and excess materials Add new duct runs to exising duct system
x Remove Lowe's job sign Completely change out duct system
Thermostat: Refrigerant Lines:
Use existing Use existing refrigerant line sets
Install New Install new refrigerant line sets
Ve ting: Notes /�� ��. 1 /' �
na Reconnect flue to the existing venting
na Install new venting
SYSTEM�.DESIGN
Manual.J.Heating Load Manual J Cooling Load,� j ;. ` �`
. � . ` � '�.� � ��.�� � v
� . � •
System Cata,log System Catalog System Catalog
Z E 2 1 O Q 1 9 l t .Zs A J 9 1
� ' .i• A , ;�.< �,� y,{�?q�, • h�'
. � ...
. .i� •_a "s-y.' � "`r �Mr:,e'
,: .,:- a ��:. .�. �. , , :. ;:.. •�� t,�• :1j� }�;' ,:.
.a. • � �#::r�;. 4r. .
,a'�t+�"+. � RUi'! .
. .., .t ., .G J .�.';�',
:�13 a14 ,15' iG �2Q. �eries ., , . ':�, .�4.�:� ��16 �20 Se[ies � , � ::�3.,,�;14��5;���;,��p.�M.�.
Series .,��.: «:_,,q�,
�,t ..'�',LY., �,�.,.:: ...� .4.,.. .�
:t y: ,: � r: 9'
:, �(� 'nna e '�.5 �.5 3:0 3 5: 4:0'S.0 7onnage. �ti:5 :��:0'';2�5,'.��:��^.�;y�a0'5:0
Tonnage 1;.5. 2:U 2,:5�3:0=3:5.�4:f1 ;5. To g „ � ; . . - -�a ��
� ;,4"� Flirnace/AH ' 4i�11/N ,,
Furnace/AH M/N Furnac%AH' M/ �.f , '
T'Stat 51'D� DLX TStat � SFE� Piogrammable r5t'�t ^ ,.�� � ��'�g�r!`�;tnable.
Y�,S Humid'ifier,�,.r. _ :;ka";,Y�S,',, x�c�+?;�INO,:
Humidifier YES , NO Humidifie�: „_ :�,'`� s�+:; Y.y
i� :u ... . ^�`, i:'.J:, .i,��{�:,. ::IN�.�.i_��.. . .��
�fiS NO . . � YES'' � �- ' �''�:,-;�z<' ��;``�- �;,`a�;h t, �
� Cle�n�� ',.� ��?YE r, ;;�:'�.:Y,,,�;. NO"
.... ..
Clean Effects Clean-Effects, $�"_ .^���.��{,
. `;` M�R���on the�•cal{?
Lowe's PSE Signature: �� 4;, K�"�'":�i`.��``��
� • Yes��. No
Trane RSP Signatur� '
04/12/2013 10 19 FAX 863 701 9025 wARDS AIR f�001/001
s,�,eu�,ozo " Cil�of Zeph��yrhiYs�APPh'catlon F.�o-e,s�aoao2�
or.R�Nwa �.�.con a ."'::"i''.
T"�-'�� 81&317-7'f22
��N� M e lM►�f owrr�an�lM�Mr
O,.urh�eun.. 99551 MsY00w00d Loop Oir•�r w�aw Nu�nb.r [�
FN SMnYM 7lqeedar NuM Owirr Pham Nwn�r 1
FN Slropr�Add�ss
J09 AOORESS Ss�'�9 _ � �� �
r- P�ncE�.wr 13�Z6-0110-OOOOD-0700
auea�nsoN A,,,.�a�r�nrm,�raw�
wp�p�p�e0 � N!W CONfM 8 AOOMLT � 910N Q � �
NISTALI REPAIR
PRO►OeCD U6[ Q 9FR [x] COMM Q OTHER
iYrE OF COdSTR�ICTION Q ��K Q FRAME Q s�� Q
��P���y� 2.0 Tai Mal pump d�sn0e
sui�awo a� aa soor�� Ndo�rt C� L� l 7�'���
"��
QBWl�iriG �� wu.uAriON OF TOTAL CONS7RUCTICN
L.-r_�J
�ELECTiiICAL � rrAP SE/MCE �] PROORE&3 ENERt�v � w,R.E.C,
QPLUMB�NO �
�__J
QMECIIM1NICAL i4�5.� VALIMnON OF MEC11I1NIGL INSTALLATION
Q�.q Q ROOFINO [� SPECIN.�`/Q OTMER
FINISNED FLOOR ELEVATIONS �� FLOOD 20NE ARE4 QYES NO
BWLOER �P�
$��� qE�ly7R� Y/N 1!lCU�A Y!
AddnM Lla�w�I
ElPC11iCIAN GOMPMII
$�p�ypE plfailrq[p Yf N FTtd►iIEP �
AAONM Llcan�s i I �
PLIIM!!R ��
$�A�� IIEpl87p�o � Y!N � FE awR61. V I N
AOC1N� LloenM�I
MRCN�wcILL GW�,, �p�y Wards FkMk+p ond Air Cor�diilioninp
��yq�+ R ,� qlp6Tp1lD Y/N ��Q CiiMlA /N
�ean.. 8B6 Credivo Dr,L�Nsie�d,FI,3981 S uanw s I CAC057633
b111ER ���
8q�,y��tlqE �ptt@OID Y!N P!l6tN1� Y N
AOd1�N LIEtlIM�(
11/111111111111�11�1111111�11111�1�1�1111111111111�111111111111/11�
q�IDlNTl1� All�d�M2)Pb1 P4m;(al�d 9uIIdnY P�nr,11)wt of EnNqy famr.ftbW PMnll br nwv eenMnrJla+.
INnlnwm lan(1D1 rwAdnY dq�dur�ubmMW dM.R�Ine anNu,CanMnebn v Wu.8ianwrw Piwr vM SNt Fena t�N�Md.
3MYrry FacrYS i 1 MInp�Mr EN!Vfpk PbMlt fOr s�bdiYi�iaiiAwi�Y��
COMMEFICIAL Aash(�)oa�MY d�u1dNp Vlw Mi+��Llh S�ty�apr,(1)�M M F.irpy Fenn�A.CMIY PpnNt b1 Mw aorwYUabn.
AWYnwm Mn(t�I weAMq d�Y�Msr�uhn�ll�aW.RpYroA nWd.CdWn+e4e�+PMne.SIO�mM10r Plnw wl SW F�na InNW�tl.
Sen11Mr F�oi150i 61 Au�qMK.61N Wak Wrmk far d new pioJ�v.N oommrcW�quYanrru muel nieal mmp�r�
sqn veR�rr �W.�u•r�in�w vwu.
--Prloventr SuRV6r nqulwa ror r�w aen.uunan.
.� - - ' -- - ''- - �i.iiYiL•• •_1i1
DV�O110N�C
Fltl oW�Y7kMbn aonpebb•
Ow�rr i Oonu�cEOr Ypn Mdc d yplalNn.noWMd
M eW�i7l00.�IMtle�ef CaMmMCM�M N wqul�A. (NCµPMd�s wM N�00)
� ,�psnt per uie raNraewy a Pewar af Aqa�(b�Me owrx�woukl be som�ans wMh�atalzed 1Mlertrom owner aue�o�trlrq wne
ovea nie couwree Po�wrrrro IFrom a,�woMbn oNr1
Rwoofs M�hlnnd�s Swwrs Swvloe urar�d�a A/C F«�ass(P���O�f
OM�w�YMNq OrOf CWh10f K p1 p�IMb loMwq�.a�sa0�ROW
Pasco County Parcel: 13-26-21-0140-00000-0760 001 Page 1 of 2
Data Current as Of: Weekly Archive - Saturday, April 06, 2013
Parcel ID 13-26-21-0140-00000-0760 (Card: 001 of 001)
Classification 01 - Single Family
Mailing Address Property Value
LANCASTER MAGDALENE Ag Land ��
HATTI E La nd $1 i,665
39551 MEADOWOOD LOOP Building �a4,003
ZEPHYRHILLS FL 33542-6714 Extra Features �8,285
Physical Address
39551 MEADOWOOD LP 7ust Value #63,953
ZEPHYRHILLS FL 33542-6714 qssessed (Save our Homes) $63,953
Homestead 196.031 - �2s,000
Non-School Additional Homestead - �13,953
�eaal Description (First 4 Lines) Exemption
See Plat for this Subdivision Non-School Taxable Value �25,000
MEADOWOOD ESTATES School District Taxable Value �38,953
PB 15 PG 106 LOT 76 Warning: A significant taxable value increase may occur when
OR 3201 PG 775 sold.
Click here for details and info. regarding the posting of
exemptions.
Land Detail (Card: 001 of 001)
Line Use Description Zoning Units Type Price Condition Value
C1� 0100 SFR OOR2 8,000.00 SF $1.45 1.00 $11,600
2 0100 SFR OOR2 250.00 SF $0.26 1.00 $65
Additional Land Information
Acres 0.19 Tax Area 30ZH FEMA �Residential Code ZHLGLP5
��� Code
Buildina Information - Use O1 - Single Family Residential (Card: 001 of 001)
Year Built 1987 Stories 1.0
Exterior Wall i Concrete Block Stucco Exterior Wall 2 None
Roof Structure Gable or Hip Roof Cover Asphalt or Composition Shingle
Interior Wall i Drywall Interior Wall 2 None
Flooring 1 Cork or Vinyl Tile Flooring 2 Carpet
Fuel Electric Heat Forced Air- Ducted
A/C Central Baths 2.0
Line Description Sq. Feet Repl. Cost New
1 BAS 1,118 $47,962
2 FSA 180 $2,703
� 3 FGR 286 $4,891
�— 4 FOP 80 $858
Extra Features (Card: 001 of 001)
Line Description Year � Units Value
1 DWC � 1987 530 $543
2 � POOL-6 1988 � 364 $4,368
3 SCRN-AF 1988 2,158 $1,942
http://appraiser.pascogov.com/search/parcel.aspx?sec=13&twn=26&rng=21&sbb=0140&b... 4/12/2013
New Construdion
.
TRANE� Whole House Worksheet
Customer'sName Magdalene Lancaster Address 39551 Meadowood Loop.
citv Zephy�hills FI. state FL ziP 33542 Telephone Number 813-317-7522
WINTER: Inside Design Temp 7� deg F -Outside Design Temp 3� deg F = Heating Temp Difference 4� deg F
SUMMER: O�tside Design Temp 95 deg F -Inside Design Temp 7rJ deg F = Cooling Temp Difference 2� deg F
HEATING COMMON DATA SECTION COOLING
HEATING COOLING
BTUH LOSS FAROR SUBJECT SQ.Ff. FACTOR B7UH WIN
GROSS WALL 1,104
1,445 DOORS&WINDOWS(Table A or B) 150 4,229
1,374 1.44 NET WALL 954 2.3 2,194
537 0.48 CEILING 1,118 2.1 2,348
FLOORS 0 1.3 0
i�nw.tta� �x.my vdw� vd� tow�t _ i�nin.ao�
B,,,M, - T,bi�o x 10 z 1 i/so x lu�W (cy Fq x 1 i/w x �T x r�we o - em/n.
1,312 = 0.8 x 0.18333 x 8,944 8,944 x o.o�s x 20 x 0.4 = 1,312
4,667 SUB-TOTAL BTUH LOSS (per 10 deg F)
X 4 ADJUSTMENT FACTOR(Table C)
18,666 TOTAL BTUH LOSS
PEOPLE 4 x 300 BTUH GAIN �2p°m'""erbcdraoinj 1.200
APPLIANCES BTUH 2�
SUB-TOTAL BTUH GAIN(room sensible only) 13,682
X 1.05 DUCT LOSS/GAIN FACTOR(Table F) x 1.1
SUB-TOTAL BTUH(Sensible Gain) 15,050
MOISTURE REMOVAL (sub total x 1.3) x 1.3
19,600 TOTAL BTUH LOSS/GAIN 19,565
TABLE A - HEATING - DOORS&WOOD FRAME WINDOWS TABLE B - COOLING - DOORS&WINDOWS
(PER 10 deg F) Factors assume windows have inside shading by dreperies or venitian
For sliding glass doors use fadors for the same type window blinds and sliding gtass doors are treated as windows
construCtion �'"�'�`�"� D01�'E '"'"'��^"
Window& F2mes hMV w� �o.w acf. iv.w o� x Area BTUH GAIN
x Area =Btuh Loss
Door7ypes Wood TIM Metal oh� 15 20 25 15 20 25 15 20 25
Single Pane N 18 22 28 14 16 18 11 12 13 57 1254
9.90 10.45 11.55
Clear 129 1,34H NE&NW 37 41 45 31 33 35 26 27 28 0 0
W ith Storm 4.75 5.25 6.50 e s w 52 56 60 44 45 46 38 39 40 24 1344
DoublePane see.sw 45 49 53 39 41 43 33 34 35 0 0
5.51 6.09 7.25
Clear 5 28 32 35 23 25 27 19 20 21 48 1536
WithStorm 3.41 3.85 4.90 SM�� 16a 158 in ia11�ias�u5 uo 0 0
Triple Pane wood-1 8.8 ios u�8.6�ns ua 8.6 ias va.z 0 0
4.39 5.46
Clear 3.80 m�.w-z 3.54.55.43.54.55.43.54.55.4 21 94.5
lalousie TOTALS 1$0 4�229
5.0
Single 1-For wood daon and
Single w/Storm polystyrene core metal doors
Skylights 2-For urethane wre metal doors
11.07 11.69 12.92
Single
oouble 6.65 7.35 8.75 TABLE D - INFILTRATION MULTIPLIERS
000r rypes 4� Winter Air Changes Per Hour
wood only - - 21 96.6 Fw«nree sro or�ess 900-�sao ssoo-zioo over ziao
Wood w/Storm 3.2 eest 0.4 0.4 0.3 0.3
Urethane Core(R-5) 1.90 Average 1.2 1.0 OB 0.7
Urethane Core 1�� voor 2.2 1.6 1.2 1.0
(R-5)w/Storm For ead'Po�v�°'T add: eest Arcr'ee C°°r
0.1 0.2 0.6
TOTALS
150 1,445
Summer Air Changes Per Hour
Fbor Area 900 or less 900-1500 1500-2100 over 2100
TABLE C - ADJUSTMENT FACTORS - (HEATING) e� o.z o.z o.z o.z
de¢F Tempenmre Di(f. 30 40 50 60 70 80 90 nreraBe 0.5 0.5 0.4 0.4
nd]ustmentFactor 3 4 5 6 7 8 9 Poor 0.8 0.7 0.6 0.5
4 w;
� , ,,�t�F; ��t�
. S �J s
Duct Seal Affidavit
Company �" a ruf /J C License# C�GD,.S �6...�3
Address ��`�'�� ��Q ��j
Permit#_ �
_ ,�G� Cc GYD[�OG>� 4'jQ-� -
����Cyf��'��
�---�� /`� affiant,hereby affirm that I am the dul li
y cense�c�ntractor of record for the above
referenced p rmit,that all of the forgoing information is true and accurate,and that the duct sealing at the above
referenced address has been completed in accordance with all applicable codes and standards.
Contractors Name(printed) �G�r� TI� ! 1 Date "—��` ��
Signature �c.c..�'�