HomeMy WebLinkAbout13-14190 CITY OF ZEPHYRHILLS
5335-8TH STREET
� (ai3)�so-oozo 1 190
BUILDING PERMIT
Permit Number: 14190 Address: 7712 KAY MARIE AVE LOT 235
Permit Type: RE-ROOF ZEPHYRHILLS, FL.
Class of Work: ROOF REPLACEMENT Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s):235 Block: Section:
Square Feet: Subdivision: GRAND HORIZONS
Est. Value: Parcel Number: 34-25-21-0170-00000-2350
Improv. Cost: 7,500.00
Date Issued: 5/29/2013 Name: JEFFERIS, CHARLES & JONES, CARLA
Total Fees: 112.50 Address: 7712 KAY MARIE AVE LOT 235
Amount Paid: 112.50 ZEPHYRHILLS, FL. 33541
Date Paid: 5/29/2013 Phone: 813-715-7422
Work Desc: REROOF METAL MANUFACTURE HOME
n �✓
��1./
�
(f t��C�
_ �
TAPE JOINTS ROOF INSP
FINAL � -�i�-� �_
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80(2)(c)when extra inspection
trips are necessary due to any one of the following reasons: a)wrong address b)wndemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d)work not ready for
inspection when called e) permit not posted on job site� plans not at job site g) work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to recoi�d a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications Must Accompany Application.All work shall be pertormed in acxordance with
Ci Codes and Ordinances. NO OCCUPANCY BEFO C.O.
ONTRACTOR SIGNATURE PERMIT OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
s»-�saoozo City of Zephyrhills Permit Applicatio�. ---- -�-��-- �so-ooz�
Building Departrnent ��\,
Oate Received rj. Q'�� phone Contact for Permitd ��� �3 �� �
-r77 r rTr-
Ownars Name V S � Q Ownsr one NN�mber (�'� `S� 1 �
Owner'sAddress /7 i 6 rvl4r�e. � OwnerPhoneNumber �---�
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Tltleholder Addross
JOB ADDRESS 1'�'\Q UeVLU.�' �-L � LOT N �iL 3
SUBDIVISION l`]►aV�� (2DilS�v PARCEL IDAt `� ���7�Z� �a' 1�"��U"o� 37C_J
(OBTAINED FROM PROpER7Y T/U(NOTICE)
WORK PROPOSED e NEW CANS7R 8 ADD/ALT � SIGN � Q DEMOLISH
INSTALL REPAIR
PROPOSED USE Q SFR Q COMM � OTHER
TYPE OF CONSTRUCTION Q BLOCK Q FRAME � STEEL Q
DESCWPTION OF WORK l C Q`* ,P� � ;e �
BUILDING SIZE SQ FOOTAGE �T HEIGHT JS� y
QBUILDING $ VALUATION OF TOTAL CONSTRUCTION
QELECTRICAL $ AMP SERVICE � PROGRESS ENERGY Q W.R.E.C.
QPLUMBING $ � � � I (� h
� lJ
QMECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
OGAS ROOFING Q SPECIALTY � OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA QYES NO
�+� )
BUILDER � I� COMPANY � G 1� C�. � �
SIGNATURE REGISTERED Y/ N F�ct�trten Y/N
Addreas �T E � �1�.R C t, 3 tt�dd a License S �CC��t'�Qj (�
ELECTRICIAN COMPANY
SIGNATURE �c�s�r�o Y/ N Fc�cuw�n Y!N
Address
License� —�
PLUMBER COMPANY —�
SIGNATURE l�GISTERED Y/ N FEE cuRa�n Y/N
Address
License�
MECHANICAL COMPANY �—
SIGNATURE REGISTERED Y! N FEE CURRE� Y/N
Address
license S
OTHER COMPANY
SIGNATURE REGISTERED Y/ N F�ctxta�n Y/N
Address
License/
Illlllltlllllllllllllllllllllllllllllllllllllllllllllllllllllllllll
RESIDEN77AL Attach(p)plot Plans;(2)sets of guiWing Plans;(1)set of Energy Fortns;R-O-W Permit fw new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Sitt Fence installed,
Sanitary Facilides&1 dumpster,Site Work Pertnit for subdivisions/large projects
COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construclion.
Minimum ten(10)working days alter submittal date. Required onsite,ConsUVCtion Pfans,Stomiwater Plans w/Sik Fence installed,
Sanitsry Faalities&t dumpster Site Work Permit for all new projects.All commerdal requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
""'PROPERTY SURVEY required fot all NEW construCtion.
Directions:
Fill out application complelely.
Owner&ConVactor sipn badc of application,notarized
If over 52500,a NoUce of Commencement is required. (AIC upgndes over j7600)
" Agent(for the conMactor)or Power of Attomey(for the owner)would be someone with notarized letter from owner au[horizing same
OVER THE COUNTER PERMITTING (Front of Application Ony)
Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoUSurvey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
• NOTiCE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restridions"
� which may be more restrictive than County�egulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
coMractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be ated for a misdemeanor violation
under state law If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work,they are advised to contad the Pasco County Building Inspedion Division--Licensing Section at 727-847-
8009. Furthermore, 'rf the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the
contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
Counry.
TRANSPORTATION IMPACTNTILIT'IES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of
use in existing buildings, or expansion of existing buildings, as specifled in Pasco County Ordinance number 89-07 and
90-07,as amended. The undersigned also unde►stands,that such fees, as may be due,will be identified at the time of
permitting. It is turther understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a"certificate of occupanc�'or final power release. If the p�oject does not involve a certificate of occupancy or
final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco Counly ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If vatuation of work is$2,500.00 or more,I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide°prepared by the Florida Department of AgricuRure and Consumer Affairs. If the applicant is someone
other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owne�'prior to commencement.
CONTRACTOR'SIOWNER'S AFFIDAVIT I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction,zoning and land development. Apptication is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that alt work will be perforrned to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies inGude but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls,Dodcs,Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
Federal Aviation Authority-Rurnaays.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V"unless expressly permitted.
- If the fitl material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume'will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction,I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating
the conditions of the building permft issued under the attached permit application,for lots less than one(1)
acre which are elevated by fill,an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or
set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building OTficial from thereafter
requi�ing a correction of emors in plans,construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permft is commenced within six months of permit issuance, or if work author¢ed by
the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension
may be requested,in writing,from the Building Offiaal for a period not to exceed ninety(90)days and will demonsVate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is oonsidered abandoned.
WARNING TO OWNER: YOUR FAIIURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COM MENT.
FIORIDA JURAT(F.S.117.03)
OWNER OR AGENT CONTRACT
Subscribed and swom to(or alfimied)before me this Sub 'bed a m�or ) � tl,;c
by -Z, �
Who is/are personally known to me w hasfiave prpduced i personal to me hasfhave p
as i�n'M�ce6'on, as idenfificaY .
Notary Public Natary Public
Commission No. Comrrussion
. ariei�R R Nwrport
Name of Notary typed,prlMed or stamped Name of N
o� �x 09/201 S
PERMtT NU�BER IIlIIIiIIiflII11IIIIIIIIIIIIIfIIIIIIIIIIIHI�IIlIIIININII
� 2013082297
PARCEL ID NUMBER: �q•�S•ZJ •�17D•ne •�35�_ � --
NOTICE OF COMMENCEMENT � a�t:1519323 R�: i0.e0
DS: 0.00 IT: 0.00
STATE OF FLORIDA 05/09/13 C. Mins�-, Dpty Clerk
COUNTY OF OQSr�
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Section 713.13 of the
Florida Statutes,the following informa6on is provided in this NOTICE OF COMMENCEMENT:
Y
1. Description of property(legal description): ker:zens er� 7x'r�• P S P6 �
---,—�-----. l�L�t 2�s -
a)Street(job)address:
2. General description of improvements: — ,- �
3. Owner Information or Lessee information if the Lessee contracted for the im rovements:
a)Name and address: �
bj Name and address of fee simple titleholder{if different than Own r listed above): N/
� c)Interest in property� Ownel'
� Contractor Intormation
a)Name and�dress: Solar Shield Industr-ies Inc /Frank McKinnev/4441 SE 53rd Ave Ocala Florida 34480
)Te�ephone No.: 352-23?-5200 Fax No.�(optional) 352-237-5202
5. Surety(if applicable,a copy of the payment bond is attached)
a)Name and address: N/A
bj Telephone No.. N/A �
cj Amount of bond: $_ N/A -
6. Lender Pp�-p 5 0'NEIL,Ph D PqSCO CLERK 6 GOMPTROLLER
0�/09113 �1�1!� �'o���
a)Name and address:_ N/A q� BK $
b)Telephone No.: N/A -
7 Persons within the State of Fforida designated by Owner upon whom notices or other documents may be senred as provided by Section
713.13(1}(a)7.,Florida Stalutes.
� a)Name and address: N/A
b)Telephone No.: N/A Fax No..(optional) N/A
8. a.In addition to himself or herself,Owner designates N/A of N/A
to recieve a copy of the Lienor's Notice as provided En Section 713.13(1j{b),Florida Statutes.
b)Phone Number of Person or en6ty designated by Owner: N/A
9. Expiration date of notice to commencement(the expiration date may not be before the completion of construction and final payment to the contractor,
but will be 1 year from the date of recording unless difFerent date is specified): N/A ,20 N/A
WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION�13.13, FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING'FWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOS SITE BEFORE THE
, FIRST INSPECTION. IF YOU IN7END TO OBTAIN FINANCING,CONSULT WRH YOUR IENDER OR AN ATTORNEY BEFORE COMMENCING WORK
OR RECORDIN6 YOUR NOTICE OF COMMENCEMENT.
Under penalties of perjury, I declare that I h the foregoing no6ce of commencement and that the facts stated therein are tnte to ihe best of my
kn 1 ge an lief.
'�' '� �a�..s E ��{'�;s
�SignaNre ot Owner or L ,a s w Lessee's(Aulhor¢ed OlficedDirecla�ar9�edManager) (Pnnt Name and Provide Signabry's TrtlelO{fice►
The foregoing instrument was acknowledged betore me this�'�day of �a 20�_
- (type of authority e.g.officer,trustee,atlomey in(ad)
by C�„� .� F T��S �s 0..,�
(Name of person) (type of auUwriry...e.g.offioer,tnistee,attaney in fact)
�0� �1°'��–�—�-s-�tK�' (name of party on behalf of whom instrumenl was xecuted).
Personalty Known � Produced ID [] �
Type of ID Notary Signature :?°o ' �p��
Prini Nam � �- ''�
�:,►
Sales Rep.Name:_ R e Ceu#• B/3,�-L77,3
METAL ROOF ONTRACT Date: S 3•�/3
4441 SE 53rd Ave. coNrnacTAMOUNr:__7���,�
Ocala,FL 34480 � ��3�.3e3e�--
DEPOSITAMOUNT:__.�2SS�Q'� ��) �
����� OO BALANCE AMOUNT:_�_z���
(866)998-3324 �����D
(352)237-5200 Office c��#
BALANCEDUE:__37'' �
(352)237-5202 Fax � � aala�e due upon canpletion orinstaHadon.
I/We ihe Ow�r(s)of the premises mentioneA bebw,hereby engage and hire SolarShield Industries Inc.,as Contractor,io fumish and install all necessary rnaterials and
labor,to install,construct and place the improvements acoording lo the tolbwirg specifwatlons,terms and condfions,on and in ihe premises below desaibed which we
warrant a�d represent that we have goal recad fitle as to pwners in our own name.
NAME ��►�sr�+c � t Gr�1 �. J�,•;f MUNICIPALIN_�'� �1�
ADDRESS .Z � _�'j���Ty ,z�o ���`j,G STATE Z�p 33Sgf
PRIMARY PHONE�',� -'7 •7¢.Z2 WORK PHONE CELL PHONE
EMAII
All provisions oI t Agreement are Iisted on the reverse side.Contrectw agrees to tumish all labor and mate�fals aceording to the tollowing spectHcations:
Fumish plans and all necessary documents to obtain Buiiding Permit and Notice of Commencement
❑ Rerrrove existing roof covering,install O 30#felt paper O Self adheared secondary wate�yartier.
❑ fjanaii existing wood deck with 2/:"ring shank naiis to meet Fbrida Bu�ding Code.
[v]�Remove ex�ng dr�p edqe from penmeter of roof Remove fla ' from around aq roof penefrations reirpve all e' ' hip and ' mater�al
❑ Remove and replace detenorated dedcing,at an addfional charge of a5.00/s.f.
_❑ Remove and replace deteriorated wood fascia,barge rafters or rafter tails,at an additional charge of$5.00/l.f. NO PA�NTING INCLUDED.
❑�move and reinstall existing aluminum soffit&fasda material at an additio�al charge of$4 00/I f
Remove wind turbines and o8 ridge vents from roof,cover openings with decking.
❑ Fumish and install ridge vent system on main ridge of sWcture,24"from eves and junctions.
❑�umish labor and mategals to construct water diverter(cricket)behind existing chimney
I�1�ish and install�Oga 48"oc Z purims p 1"x 4"wood purlins 24'oc
� ish and mstall I soc anurate with radiant barrier on both sides,tape all seems Nrith 2"fal ta
F nish and install prefinished metal drip edge,valiey,hip,ridge,endwall,sidewall and chimney flashings.
___ Fumish and install new flashing around all roof penetrations,painted to match roof.
❑ Fumish and instail 1"T polyisocyanurate insulation board secured to deck usin 3"d plates and screws
❑ Fumish and install tapered polyisocyanurate insulation panels,'/<"per foot slope,secured to deck using 3'd plates and screws.
❑ F ish and install ultta ply TPO Roof System,cobr to be white.
F ish and install a Solarshield metai roof system on all sloped areas of roof,including him accessories.
F sh client u com letion a Waive of Lien and Transferable Lifetime Wartan .
C�lean up and dispose of all job created debris.
[f .�
_U Style: �����tc� �/ � �
_ �Guage:__�(s _ L�J Cobr. �- �
The undersigned Conhadw agrees to setl and the undersigned Buyer(s)�ointly arxi severa�ly,rf more than one)agrees to p�a�the above descri�y y�p�s a services
which are to be fumished or used in the modemiza6on,rehabilitation,repair,aiteration or improvement of real propeAy bcated at Buyer's address given above.
APPROXIMATE START DATE��5 APPROXIMATE COMPLETE DATE__��
(Fran finance approvap
ACCORDING TO FLORIDA'S CONSTRUCTION LIEN LAW(SECTIONS T13.OU1-713.37,FLORIDA STATUTES,�THOSE WHO WORK ON YOUR
PROPERTY OR PROVIDE MATERIALS AND SERVICES AND ARE NOT PAtD IN FULL HAVE A RIGHT TO ENFORCE THEIR CLAIM fOR PAYMENT
AGAINST YOUR PROPER'fY. THIS CLAIM IS KNOWN AS A CONSTRUCTION LIEN. IF YOUR CONTRACTOR OR A SUBCONTRACTOR FAILS TO
PAYSUBCONTRACTORS,SU&SUBCONTRACTORS OR INATERWL SUPPLfERS,THOSE PEOPLE WHOARE OWED MONEY MAY LOOK TO YOUR
PROPERTY FOR PAYMENT,EVEN iF Y0U HAYE ALREADY PAID YOUR CONTRACTOR IN fULt.IF YOU FAIL TO PAY YOUR CONTRACTOR,YOUR
CONTRACTOR MAYALSO HAVE A 11EN ON YOUR PROPERTY. THIS MEANS IF A LIEN IS FILED YOUR PROPERTY COULD BE SOLD AGAINST
YOUR YVILI TO PAY FOR LABOR,MATERIAIS,OR OTHER SERVICES THAT YOUR CONTRACTOR OR A SUBCONTRACTOR MAY HAVE FAILED
TO PAY.TO PROTECT YOURSELf,YOU SHOUtD STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYMENT IS MADE,YOUR CONTRACTOR
IS REQUIRED TO PROVIDE YOU WITH A WRITTEN RELEASE OF LIEN FROM ANY PERSON OR COMPANY THAT HAS PROVIDED TO YOU A
°NOTICE TO OWNER"FLORIDA'S CONSTRUCTION LIEN LAW IS COMPLEX AND R IS RECOMMENDED THAT YOU CONSULT AN ATfORNEY.
ACCEPTqNCE-The prices,specificatbns and conditions are satisfadory and are hereby accepted. SOtARSH1ELD INDUSTRIES,INC.is a to do the work as
speafied. Payment will be made as speafied above.
B� Daie '�
��� Da� S 3•e?�7� Co-Buyer_ Date
BUYER ACKNOWLEDGES RECEIPT Of THIS CONTRACT IMMEDIATELY UPON THE D�CUTNM/HEREOP.
GENERAL CONTRACTOltS/CGC-046502 ROOFlNG CONTRACTOR i CCC.p42979
NO VERBALAGREEI�NTS WILL BE HONORED.ITEMS ORDERm MUST BE ON CONTRACT.
Thb's a Iegalh hindinp contract If iwt PoM1l�nderstoad,saek eompMeM advice.
.`f��t'
=%�r '�
�s�:�' �s�
. �t9
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
� , Q, ' �
� Contractorl�omeowner: � , �
�_ �,�,�1�,
Date Received: .� l� —��
Site:
Permit Type: � � � �
/
Approved w/no comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑
This comment sheet shall be kept ' the emut and/or plans.
� r
/L' s->>-�j
Kalvin Switzer—Plan xaminer Date Contractor and/or Homeowner
(Required when comments are present)
Florida Building Code Online rage i oi �
:sjr,w :ir� 3f} .;�;� 3:;i�,a. 3:{.. '2�'.: :� '*�'"',�e'y�`�'1c�, 'r'' `'„` �>p,'-..*`�#^_ -;;--r�:z�i- - �.
?:�,";��'�t}� '� "^��."+� � '��� 2� ,r' . Sl:'~ � �-uy �� e
's`"�� .��' �'�� t f� y _��-j,., c�'`�,a �_f�4�",
'` _ 3:�`_ !?sa'�;� �` d°,"`.,''�'",�,'i�.- 5�',3fi.k�r,?�3'�'` hd'�'4 - � �t $a� r .. - � ,...
_ . _ ... . S. . 'art"� . �—. ...� u. .o- . ....y. Y.,��.. �
BCIS Home Log In User RegistraCan Hot Topics Submtt Surcharge Stats&FaUs Publicatiorss FBC SWff BCIS Site Map Links S�rch
Busines,
Professional �uPse�c�bi�uApP�oval
Prc�i,c_appro�_al'�ienu>ProduR or Ao�fication Search>ApplitatiOn LLat
- - , iSearch Criteria Refine Search
�Code Version 2010 FL# 11651.23
Application Type ALL Product Manufacturer ALL
'Category ALL Subcategory ALL
Appiication Status ALL Compliance Method ALL
Quality Assurance Entity ALL Quality Assurance Entity Contrect F�cpired ALL
Product Model,Number or Name ALL Product Description ALL
Approved for use in HVHZ ALL Approved for use outside HVHZ ALL
Impact Resistant ALL Design Pressure ALL
Other ALL
— -- --------- ------------------------
i5earch Results-Applications
FL# Tvpe Manufacturer Va{idated Bv Status
FLi1651-RS Revisfon Guif Coast Supply&Manufacturing,LLC. Locke Bowden Approved
Hisi6t"V FL#:FLi1651.23 (334)3U0-1800
Model: 26 Ga.Tuff Rib
Description:26 Ga.Tuff Rib Roof Panel over 15/32"Piywood
Category:Roofing
Subcat o :MeWI Rooflng
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratlfkd by the POC and/ar the Commissim if necessary.
Contac[Us::1940 North Monroe S[reet.TaiWhassee R 32399 Phwre:850-467-1824
The State of Florida is an AA(EEO employer.Coovriaht 2007-2010 State of Florida. Privacv Statement.:Aecessibilitv Statement::Refund Statement
Under fbrida law,emaH addresses are public reoords.Tf you do not want your e-mail address released in response to a public-records request,do not
serW electronk mail to this entity.instead,coMact Me dRCe by pMne or by dadRional mail.If you have aM Q�^5.Ptease contact 850.48�.1395.
`PUrsuant[o Section 455.275(1),Plorida Statu[es,elfective Octo6er 1,2012,Ikensees Iicensed under ChapOer 455,F.S.must provide the Department
with an emafl addres if they have one.The emails provided may be used for offkial communicatfon with the licer�see.However email addresses are publK
record.If you do not wish to wpply a personal address,please provide the Departrnent with an email address which on be made available tn the publfc.
To dNermine if you are a lice�ee untler qwp[er 455,F.S.,piease didc liere
Produd Approval Acaepts:
�� �� �
xYrurit�-�:�i�:��
����LLW4�K.SHA�L C9MPLY WITH AL
PREVAILING Cd1��S,���D CODE AND
CODE,NATIQ��LELLS ORDINANC�S
CI'TY OF ZEPHYRHIL
REVIEW LIATE��Z. ��.
�ITY 4F Z��MYR�II�LS
PI,�N��,�IMlIMI���_
http://www.floridabuilding.org/pr/pr_app_lst.aspx 2/27/2013
( GENERAL TERMS
ROOFTERMINOLOGY
SSMR1107
�q� VALLEY
SSMR1105
S5MR1108 i�DGE CAP
SIDE CHIMNEY
SSMR1106
HIP
SSMR1103
fAVE/OVERHANG
SSMR1104 �
RAKE/GABLE �
�
�
�
�
�
�
TRANSRION SSMR1109 SSMR1108 SSMR1108
PITCH BREAit S�EWALL RASHIIVf ENDWALL FIASHINf
---=` � H�r ca�n�n��r n��s w.�w �rro
i—` \ =u t SE 53•d Rvznee SPEpF1Cl1 REPARED BY YE OR
� . �� Y ,° .,� � �, , O o:..,�,r-=��aa�.�o GENERAL wroQr o�cr suP son
`� � w+�+ so�o �ow
�� ��=.,y� ..��� :� � ��� �
G�Ni813)e99-1173
° F�ix(3�2j 237-52fi2
'-86"o-N8-?314 PAGE
c_-c���c::cc,cu�s�,:.� T J 8 Y P.E. /� 26153 DATE
RuXrvj�r.;GCCt?t28J9 8568 NG d AVEM/E
L•.e-�seJ�do:c�i•I�s�uxl FRANN AdCKINNEY � OC 34474 l�j��
pHpNE ] (G/f
:�r,r¢�'ar,hie;droofing_com � �"!'s��+!�ecrorin�.o r � �) �`—�t?
FAX (352) 854-8923
� -- —
TABLE OF CONTENTS
DEfAIL NUMBER DESCRIPTION PAGE
SSMR1000 GENERAL TERMS 1
SSMR1100 FASTENiNG SCHEDULE FOR 5-RIB PANEL 2
SSMR1101 LOW SLOPE ROOF APLICATION 3
SSMR1102 METAL PURLIN LOCATION AND CONNECTION 4
SSMR1103 EAVE AND OVERHANG CONNECTION 5
SSMR1104 RAKE AND GABLE CONNECTION 6
SSMR1105 RIDGE CONNECTION 7
SSMR1106 HIP CONNECTION 8
SSMR1107 VALLEY CONNECTION 9
SSMR1108 SIDE AND END WALL CONNECTIONS 10
SSMR1109 PITCH BREAK FLASHING 11
SSMR1110 AND PENETRATION CONNECTION 11
i �er c�rtm�r niAr niis a�.�ur aro
,.-"`�~f \_
cs.ii SE:i3•d Aven�e SPEClFlCA11 PREPARED BY ME OR
- 9., a � � ��g �� -t>.Q O��a,7=!orida 33,30 UM�NOER N 2010 FL w�
� . .r
y k.
;3 �.��.s�:v� '�:��: .3� .-� Ce�{R1J)233-i173
� os � Fax17"a2)2J7-5202
' i-S�o-998-332A
c-::�:�!c�=cs,ccwo�[� 08ER J B Y . � 261 DA
w �
?;wfrv3 Lc;Ci.CC�i2873 6 OC1LLJ1.6 34474� G� /Z
L r.��sed•?c-c*.1•!:-+�txl FRANK?+1CKfl�lNEY
PHONE (352) 854-9612
vr!:.v�arah;s�srooiio�ccm � ��:��,�y:��r:.`���.� FNi ('a32) 854-8923
SSMR1100 FASTENING SCHEDULE FOR 5-RIB PANEL
#9 X 2'W04D ZAC LAP SCREWS
BUM SEAWVT OPTIONAL�NOT REQUIRED)
#9 X 2' WQOD ZAC FASTENER(1YP.)
SIDELAP DETAIL
EAVE FASTENING SCHEDULE
ONE FASTENER INSTALLED AT
EACH SIDE OF MNOR RIBS
STITCH SCREWS INSTALLED
� � AT ALL SIDELAPS ON R40f
� � 9{Tya,j � � � '�
�� � �.
INTERMEDIATE FASTENING PATTERN
FASTENERS INSTALLED AT EACH g���Eyyg�NSTALLED
� SIDE OF MA10R RIBS 48'O.C. 1 FASTENER AT 24'O.C.
� � � '� 9�yp,�j�--�—�` � � � �
----�� � /�--
*S10PE-THE RECOMMENDED MININ�IM SLOPE FOR ANY 5-RIB OR TUFF RIB ROOFING PANEL IS 2:12. L,ESSER SLppES MUST USE qN p�DED VALLEY
AND FlASHING SYSTEM,BUT NO ROOF SLOPE SHALL BE LESS THAN 1/2;12,
*SUBSTRUCTURE-PANELS ARE DESIGNED TO BE UTILIZEp pVER A SpUD SUBSTRATE,BUT CAN EASILY BE USED OVER OPEN STRUCTUREFRAMING. TO
AVOID PANEL DISTORTION,USE A PROPERLYALIGNED AND A UNIFORM SUBSTRUCTURE.
*AVAILABIUTY-29 GAUGE,26 GAUGE
*APPLICATIQN-COMMERCWL,ARCHlTECTURAI.AND RESIDENTiA(.PANEL
*FASTENING SYSTEM-DIRECT FASTEN(p(pOSED)
*FASTENERS-THE FASTENER SELECTlON GUIDE SFIOULD BE CONSULTED FOR CHOOSING PROPER FASTENERS FOR SPECIFlC APPUCA11pIVS. QUqNjmr
AND TYPE OF FASTENER MUST MEET NECESSARY LOADING AND CODE REQUIREMENTS.
*MATERIALS-GALVALUME tm OR GALVANIZEp PAINTED OR NON P�lNTED
*MATERIAL FROVIDERS FLORIDA APPROVAL,fL#11651. (provided t�r others�
---'� ' =-� �.i t SE 53�d Avence TYPICAL �,�"�BY c�nFlr n��T n�us au� �
� .� . � .a� o:�ra.F�c�da 3.�s,3o r'�'�u er� at
?� a� ' a O UN NY DIRECT PERNSION
j ��: �� 3� ',3 u.��a� � DETAIL MA iHE 2010 Fl A BUtt,D9r
��� C�rB(813►299-f T73
— — Fax{3�2)237-SZr2
,�ti���„�`::��,;,SU., 1-3fiw498-3324 PAGE
'�rtlfr.ry L-s.�CCCas29�� R T J ADY P.E. � 261 ATE
Lra�sc.l•2n-�I•r-sur�1 � M� d AVEI�IE !
FRANK kiCNINNEY � fL 34474 ��/��n
°n:R¢�,�rshietdiootng.corn � �"'�soa;neicroo'ing.ccm PH4NE(352) 854-4612 �`� G
FAX (352)854-8923
SSI�R1101 LOW SLOPE ROOF APPLICATION
ROOF SL4PE - 1/2:12 SYNTHETIC SOLDERED SEAM
3/32'X 1/2'BUTYL TAPE SEALANT
#9 X 2' WOOD ZAC FASI'ENER(TYP.)
STITCH SCREW
#9 X 2' WOOD ZAC
#9 X 2' WOOD ZAC FASTfNER{TYP.)
FASTENER f TYP.)
SIDE LAP DETAIL
#9 X 2' WOOD ZAC FASTENER(fYP.)
STITCH SCREW
#9 X 2` WOOD ZAC
FASTENER(TYP.} 3/32'X 1/2'BUTYL TAPE SEALANT
� � � � � � � � �
UNDERUIYMENT.SEE NOfE&1 INSUTATfON SEE NOTE�2 ROOFMG SEE NOTE A3 DECKWG SEE NOiE N4
CROSS SECTION OF LOW SLOPE ROOF APPLICATION
L INSTALL 30#ASTM D 226 TYPE II UNDER LAYMFM OVER 1/2'T ISO BOARO OR ANY APpRpYEO METAL UNDERLAYMENT HAVING A CURRENT FLORIDA
PRODUCT APPROVAL
2.1/2" T OR R MAX POLYISOCYANUR,qTE pLA$TIC RIGID lN,SULATION BOARD.
3.IXISTING ROLLED ROOFlNG MEMBRANE COMPRISED OF NUMEROI�KNOWN ROOFlNG APPUCATIpNS,
4.EXISTING WOOD DECKING COMPRIMISED OF A MINIMUM OF 15/32'OF GREATER PLYWOOD DEGtiNG.
i �r coRrn�r n��T n�is r�.�w u�o
�—�- �--� =.s.31 SE 53rd Aven�e TYPICAL s�aACnnars� rx�,�n eY►� o�
3 ,3 '� � °? 1 �� 0 O�Ia,F!ortla 3Ja30 UNDER CT SUPERNSION ANO COMPLIES
�-� ;.►�;.���:3�_� ::� ����:� DETAIL � 2�, �«�� �
� ;Y
�s � Ce�(873)294-1773
Faz�3�2)237-5202
C.:raral t;c-CGGO�d�: "•3�-�83324 PAG E
R,>•r��c:cccca2s� � T �d�D��P.E ;� 26153 ATE
L:��sed•30��;•l::aa d FRANR b1CKlNNEY � ��. FL 34474 �Q�g//2
:���:.a�'�rshie'droofing.com � 6r;a3suarsiieicrecvuw.a.n � (352) 854-9612
FAX (352) 854-8923
SSMR1102 METAL PURLIN LOCATION / CONNECTION
����
��.T��
�����
k9 X 2'WOOD ZAC FNSTENER(TYP.) 5 R�BED ROOF PMIEL
PAINTED TO MAT(�t ROOF
Z�
1
��
� ROOF DECNING
5/8'X 1/2'X 2'X 22 f�l STE�.
T PURUN.pT 48'0.C.MICNORED � 1/Y THK POLYISOCYANURATE
THROUGH E105tING ASPIW.TSHNGIES RNYD MISIRATpN
INTO ROOF DEq0W6 WftH 2 3/S
RING SHMIK NAN.S AT 12'O.0
CROSS SECTION OF TYPICAL INTERMEDIATE LOCATION
tov��snnc sF+urc�o r�oA�a�waoo oEac�
�szrw000�ncFas►��m�r.� �or�cuwa�uT�s
rucm�r�o.c.�o�
TOROOFTRUSS
5 RIBBED ROOF PANEL
O �
TAPEAI.L101NTS OF POLYIS06YMN1RATE fOMi
�Jq10N BQARD I�IIi 2"WIDE F0�TAPE
ur n��.aav�ocvvar�u�a�
RlGID INStlLA71pN
SUBSTRUCiURE
oasr�c s�ur�
Of ASPHALT SHNVGI.ES OR
�rn�n woou o�ac ov�a Mu�
�������
isoM�rRic viEw
.�.!%�Ca TYPICAL �"���nFr n��r n��s � �rro
-.i11 SE 53�d Aven�e PREPAREO BY A�pR
3 ;� '� ?i �s Q 0�<�,f'orida 3�1a0 UNDER RECT PERN90N AND
.t p� �� �.; �� �� 3� DETAIL rxTM so�o�t �euaon�c
��_y�� . `,� � m �
�'������R CeN{813)293-1l73
���� .ta�cvn_���� c�xf352)237-�202
���,��.�:;��,��� '•3Cw-998332d PAGE
R T J ADY P.E. � 261 TE
:r«,r���c�ccccszs�a g� w ��
L Cen4erl•Bn-t;?�}•;:.su�.wl FRANK i�r1CKINNEY � fL 34474 ���/ �Z
�.•r.:x.soiarshietdroofing.:om Bc:-�,so'arsceacr�aro.a�n �' PHONE ;352) 854-36!2
FAX (352) 854-8923
SSMR1103 EAVE/OVERHANG CONNECTION
uz��.������ a����
RIGID INStAAT10N OF ASPNALT SHINGLES OR
PREPARED YYOOp pEp(
5 RIBBED ROOF pANEI
I
3'WIDE FAt�2A5TENED TO PEI�METER �pN""�
WOOD NAItER WITH 11/4'
RMI�SHANK NA�S 4'O.0
STM�'iQiED
INSTALL A 15/32'X 31/7 YYOQD NNLER
AROUND COMPLETE PERAMETER OF ROOF
INCLI�IN(i EAYE RN(E,RIDGE,HIP
AND VALLEY,fASiENED TO WOOD DEq(
WITH 2 3/8'RING S111WK NA�S AT 12'O.G
CROSS SECTION OF TYPICAL EAVE/OVERHANG
�o���aooF o��u�woo�o�aq
5 RIBBED ROQF PANEL
urr��c.ao�r�socr�rur��
RIGID INSULATION
#9 X 2°WOOD IAC • SUBSTRUCTURE
FASTENERS .
EAVE FLASHING �-15/32'X 31/2"WOOD NqA.ER
*NO FORMED CLOSt1RE REQUIRED FASTENEp TO WOOD DEq(
WtTH 2 3/8'RING SHANK NAILS
AT 12'O.C.
NOTES:
L TAPE ALL JOlNTS OF POLYISOG�'ANURATE FOAM INSULATION BOARD USING �SOMETRIC VIEW
2' WIDE FOIL TAPE.
2. ATTACH EAVE FIASHING TO PERIMETER WOOD NAILER WiTH
11/4"RING SHANK NAILS 4'O.C.STAGGERED PATTERN
3. ATTACH PANEL AT EAVE WITH#g X 2�1Nppp ZpC FqgJENER,ONE
FASTENER ON EACH SIDE OF MA10R RIB AND ONE AT SIDE IAP.
4.ALLOW ROOF PANELS TO D(TEND 2'BEYOND EAVE TRIM fACE
5 5 RIBBED ROOF PANEL TO BE OPEN AT ENQS FOR PROPER VENTILAT(ON.
(NO FORMED CLOSURE REQUIRED)AT EAVE,
'' ► ►+o�er c��r n�ar n�is ri.�w u�
/ �� c.��sE�•a n�,.-��� TYPICAL sa�aFlC�noNS w�a�,v�n er�a�
;� ; � ��I :.�;� '� ��� o o��.r-�o�;a��o DETAIL ��w so,o ��� c�uEs
� �.�� -��.�� ��� ��
��� � ,� �_.
CeB(813)299.i 773
• Fax(352j 2375Z02
G�^wal L•c rrGGC0;6„`62 �•'�E�-99&332d PAG E
R;xien,fl,c.:CCCt3,ttb� R T RAD . �! 281 A7E
6568 82nd AVp�IIE
L cazse�•do<::�,;•��c�msl FFtANK IdCKINNEY � �CAU1. FL. 34474 ����2
:�ncv.�I3rsMe?dreofing.cam �4rso4vsirel6eaf'na.un � (352) �5i-9612
FAX (3S2)854-8923
SSMR1104 RAKE/GABLE CONNECTION
u2'TM������ 5 RI88ED R0�PANQ
RIGID IN5UUi�1
EXISTING ASPHALT SHIN6lES OR
PREPARED WOOD DECK
rra��c.�wsr�u
�x uz��r000racm�r.�
AT24'O.C. �Y���
eooF Parta an��NC,i�sraLL ROOF DECKING
15/32'X 31/7'4NOOD NAILER �9 X YYYOOD 1AC(tYP.)AT 24•O.C.
CROSS SECTION OF TYPICAL RAKE/GABLE
lov�o�rn�s��n�o���n w000 o�ac�
#9 X 2'WOOD ZAC(TYP.)
5 RIBBED ROOF PANEL
1/2'THICK.POLYISOCYANURATE
RIGID INSULATION
INSTALL RAKE FLASHING ON TOP
OF ROOF PANEL FASTENED TO FACE SUBSTRUCTURE
WITH A#9 X 2'WOOD ZAC 24'O.C.
F�STENED TO ROOF WITH
A#9 X 2'WOOD ZAC 24'O.C.
15/32'X 31/2'WOOD NAILER
FASTENED TO WOOD DECK
WITN 2 3/8'RING SHANK NAIIS
AT 12'O.C.
iso��ic v�Ew
NOTES:
i.INSTALL RAKE FLASHING AT TOP OF ROOF PANEt,APPI.Y BUTYI.TAPE SEALANT ALLOW RAKE
TR1M TO OVERHAN6 A MINIMUM OF 1'ON EVE OF ROOf OR EQUAL MEASUREMENT OF ROOF PANEL OVERHANG.
2.FASTEN ROOF PANEIS 24"O.C.UP RAKE USING#9 X 2'WOOD MAC SCREWS.
� � �er artt�r t�nr �ns r�w iw�
_i' '�-` =s.i t SE 53rd R�rene.e TYPICAL SPECIFlCATI PREPARFD BY AIE OR
�� �?� � €� •�� Q O�►la,For�la 3i�0 UNUER PERNSION AND COYPlJES
� � �j �y-y� ..;�� � DETAIL �+TM so,o � euwwc
�� �� '.i�e�-:,.5 :-4 r} ai 3 ,
CeU{H13yi93-t173
� � Fax�352)237-5202
'•3c6-998332d PAGE R T J ADY E. � 2 OATE
Ger.�rsl(,c YCGCWeS(T!
z•�r�,��.;ccca�2er� 6568 d AMFJ�IUE
l c?�s�J�f3o�dr'd•L•:surwt � OCALA. FL 34474 �/���
FRANK MCKIMNEY
:•r.ti�¢.,'arshietdreoring.com � �::gsoa�'�d�'�g.cc:ro °�� f332) 854-96i2
FAX (352)854-8923
SSMR1105 RIDGECONNE
CTION
#9 X 2'WOOD ZAC(S'EE NOT�
14`WIDE X 26 GA.RIDGE FLASHING 13/4'WIDE RmCUTATED
RIDGE VENT MATERIAL
5 RIBBED ROOF PANEL
15/32'X 31/2'WOOD NpILER
1/2'THICK.POLYISOCYANURATE
RIGID INSULATION ROOF DECKiNG
TRUSSES OR RAFTERS p(�ry�qgpHq�T SHiNGLES OR
� � PREPARED INOOD DECK
CROSS SECTION OF TYPICAL RID6E CONNECTION
cov�o�c s�u aoaF�a�aa�o w000 o�c�
#9 X 2'WOOD ZAC FASTENERS,9'O.C.EACH SIDE OF RIDGE
14°WIDE X 26 GA
RIDGE fIASHiNG 13/4'IMDE RmCUTATED
RID6E VENT MATERIAL
5 RIBBED
ROOF PANEL o
15/32'X 31/2'WOOD NAILER
FASTENED TO WOOD DECK
WITF!2 3/$'RING SHANK NAILS
AT 12'O.C.
1/2`THK.POLYfSOCYANURATE
RIGID INSULATlON
EXISTING SHINGLE ROOFlNG
QR PREPARED WOOQ DECK
SUBSTRUCTURE ���
L CUT PANELS 2'FROM CENTER UNE OF RIDGE
ISOMETRIC VIEW 2.INSTALL 13/4'WIDE REIICULATEp g(�qq(FOAM RIDGE VfIVT
MATERIAL ON EACH SIDE OF RIDGE REMOVE ROOF DEq(ING F�
CLOSURE AND VENTALATIpN,
3. ATTACH RIDGE fIASH WITH#9 X 2�WppD ZpC FASTENERS 9'O.C.
INSTALL FASTENERS AT EVERY Ni6H R!B IN THE PANEL TO AVOID DIMPLING
THE RIDGE FLASH.
"� � TYPICAL � "�r c��r TM�r TMis p.�w �
_---' �--` :s::�s�sa-d n,�n:� s� w��u�n er� at
.9 �; � � ; t �p OGNa,finrida 3�R0 Y CT�y�9q1 IWD CpApL1Eg
� d���,;,��� �� ��:�i�� �� DETAIL w� � so� A �11LDlNG
+ .� � �
Cep(813)299-tT73
� _ F�i��2)237-SF02
Cr�rcr�lUc:�CGGU;h�7? i-��-4�-332d PAGE
Ra�rn,7�c;CCC�t2s�9 R T BRADY P.E, (! 26153 OATE
Lce:�s•_�d•��-c'cai•tn:ur9c! � 62nd AVENUE
FRANK MCKINNEY OCALA' FL. 344J4 �j/Q�Z
:n�nv.sc:arh�e:dreotmq.ccm � u�gsoars'r..eicroora�g.aro �C�ME {-_�52) 854-9512 �/
FAX (352) 85�--8923
SSMR1106 HIPCONNECTION
14°WIDE X 26 GA.HIP FLASHING 6'WIDE ALUMINUM BACKED PEEL AND SEAL
#9 X 2'W000 ZAC(SEE NOTE}
5 RIBBED ROOF PANEL
WOOD NAILER ON EACH SIDE OF HIP
1/2°THICK.POLYISOCYANURATE ROOF DECKING
RIGID INSULATION
EXl.STiNG ASPHALT SHINGIES OR
TRUSSES OR RAFiERS ��'�ED WOOD DECK
{ I
CROSS SECTION Of TYPICAL HIP CONNECTION
cov�oasnbc si+p�u�o�a�n�m woo�o�c�q
#9 X 2'WOOD ZAC FASTENER ONf 14'WIDE X 26 GA HIP FLASHING
FASTENER ATOP EACH HIGH RIB ON EACH SIDE
5 RIBBED ROOF PANEL
0
6'WIDE ALUMINUM BACKED PEEL AND SEAL
urn��ac.�a.r�soc�nruuw►r�
R1GID INSULATiON(SEE NOT�
15/32'X 31/2'WOOD NAILER
SUBSTRUCTURE F�NED TO WOOD DECK WfTH
2 3/8'RING SHIWK NAtLS AT 12'O.C.
ISOMETRIC VIEW
N(}TES:
L BEVEL CUT PANELS TO MATqi SLOPE Of HIP AND INSTALL
2 ATTACH HIP FLASH WITH#g X 2■Wppp Mq�FpShNERS AT EVERY HIGH
RIB IN THE PANEL TO AYOID DIMPLING THE RIDGf fLASH,
3.INSTAl16'WIDE ALUMINUM BACKED PEEL AND SEAL CENTERED
ATOP OF HIP FLASHIN6,
=-;`'���!%�\�\� _s��sE��-d n��,�a I HEREBY CERTIFY 1HAT 1HIS PLAN M�
.�a�. � -;�.��= � :�� �. Op o��.Fro�aa a��o
TYPICAL ���cnnoNS +�ar�,v� er� os
-, ,f�� �°� �� DETAIL w+�+ 2mo o�A ��cAN° c�rPUEs
a'� �.:�.'���a��� ��
�, � CeM{N13)239-1773
° � Fax t3�21237-5202
G�rc,nit�c?tCGGO4e5oz ?-8H6-898-332d PAGE �
RG'ifr.�J Lc�CCC�}t2S73 R08 T J ADY P.E. /! 26153 ATE
L,ce�secl•3orc'Fd•�rsued 6568 d Ay�
FRANK B,�KlNNEY Q �CALA, FL 34474 �p��/�
:nGlv.aaar,iiieidroofmg.com �r.:3soarsieeicroermq,cc.ro Q ��IE (352; 854-46t2 �
FAX (352) 864-8923
SSMR1107 VALLEY CONNECTION CONNECTION
18'WIDE VALLEY f111SHING #9 X 2'W�D IAC
APPLY 1'X 1'CLOSED 5 RIBBED ROOF PANEL
CELL FOAM CLOSURE 1/2'THICK POLYISOCYANURATE
RlGID INSULATION
I ( EXISTING ASPHALT SHINGLES OR
� �
PREPARED WOOD DECK
TRUSSES OR RAFfERS
15/32'X 31/2'WOOD NNLER ON
E�ICH SIDE OF VALLEY
ROOF DECKING
CROSS SECTION OF TYPICAL VALLEY CONNECTION
cov�oasnric s�o aao�o�a�ru�waoo u�aq
SUBSTRUCTURE
5 RIBBED ROOF PANEL
1/2'THICK.POLYISOCI�ANURATE
RIGID INSULATI�V
18'VALLEY FLASHING BEVEL CUT PANEL TO
MATCH SLOPE OF
APPLY 1'X 1'CLOSEO CELL VALLEI'FLASHING
FOAM CLOSURE
5 RIBBED ROOF PANQ
ISOMETRIC VIEW
NOTES:
FASTENERS TO PENEfRATE THROUGN L 18'WIDE X 10'LONG 26 GAUGE'IM TYPE VALLEY FLASHING FASTENED
ROOF PANEL,UNDERLYING W�D NAILERS,IAYER 1"FROM OUTSIDE EDGE WITH 2 3/8'RING SHANK NAIIS AT 12'O.C.
OF ASPHALT SHINGLES,D(ISTING WOOD DECKING 2•BEVEL CUT PANEL TO MATCH SLOPE OF VALLEY,
USING#9 X 2'WOOD ZACS AT A RATE OF THREE 3.FASTEN PANEL WITH#9 X 2'WOOD ZACS AT 4'O.C.MAXIMUM.
FASTENERS BETWEEN EACH MAJOR RIB 4.APPLY 1'X 1'CLOSED CELL FOAM CLOSURE MATERIAL UNDER SCREW
LJNE ON EACH SIDE OF VALLEY,
�—'�...---'" , i H�er c�nFr n��r ni�s �w �
_ \ -s3i 5E53rd ni::�u:e TYPICAL SPECIf�AT10NS YYERE pREpNtEp BY ME OR
� "� � ��� �� ' . QR O�la,F�orida 3da80 UNDER PERV190M AND COYPLIES
;' � ' �-�� � DEfAIL w�ni E 20�0 � � ein�c
� '� x:.�.��'� ���.�a�.
� CeC(813)299-t773
� � �ax(352}2375202
G.'r.�tal L:C N���;6..� {•dEo-49&3324 PAG E
R08ER J B Y P.E.
�cWr,Y3�c.;c:.coua:� � 261 3 D TE
6568 S. d AUENUE E����
L ca-WC1•�-c;cKi•h:w�d FRAMK FRCKINNEY � ��. R- 34474 (�/
er,r,v.>c�ar,hie[droonng.cem � 5rrgsoarsii�;creare�g.a:n PHOHE (352) 854-98l2
FAX {352) 854-8g23
SSMR1101 WALL CONNECTIONS
WOOD SIDING APPLICATION STUCCO APPLICATION
SIDING MATERtAI INSTAII POLYURETHANE SEAIANT
#9 X 2'WOOD SCREW AT 24'O.C.ON PANEL FlELD FABRICATE CAULK BEAD ON ENDWALL Fl.ASHING
ENDWELL FLASNING NQTCHED #9 X 2'WOOD SCREIN AT 24'Q.C.ON PANE�
TO FlT OVER RIBS OF PANEL ENDWELL FLAS1iING NOTCHED TO FlT OYER RIBS
(CLOSURES NOT REQUIRED) OF PANEL (CL06URES NOT REQUIRfD)
#9 X 2'WOOD SCREW AT 9'O.C.ON PANEL �9 X 2�WOOD SCREW AT 9'O.C.ON PANEL
5 RIBBED ROOF PANEL 5 RIBBED ROOF PANEL
APPLY i'BUiYL SEALANT
BEHIND Fl.ASHING
END WALL FLASHING CONNECTIONS
SS M R 1108
INSTALL POLYURETHIWE SEALANT
SIDING MATERIAL FlELD FABRICATE CAULK BEAD
ON SIDEWALL FLASHiNG
#9 X 2"WOOD SCREW�24'O.C. #9 X 2'W0�SCREIN�24'O.C.
5 RIBBED PANEL APPI.Y 1'BUTYL.SEALANT
BEHIND FLASH G
5 RIBBED PANEI
APPLY BUM SEAUINT TAPE APPLY BUTYL TqpE
BETINEEN FLASHING LEG AND PANEL BETWEEN Fl.q$HING LEG AND PANEL
SIDEWALL F�.ASHING CONNECTIONS
�/ /�A i ►�r c��r TM�r TMis w.� �
�-�� I `�` d1d1 SE 53�d Avzn�e i f P�td1� SPEqFlCAiIONS WERE PREPARED BY ME OR
��; �� � Oc�la,F!orida 3�FaA0 DETAIL �� (�HPLIES
� j�}� � ,�. QQ UNDER A{ SUPERNSON MID
:�.��� �� _�,�,��'�.�� NRTH 2O10 OWDA BU
Ceq(813)��,4-i773
� � Fax�352)237-5202
C.rtY�ILcttGGC0.1�5a2 '•3cw998•3324 PAGE
R T RAD E. � 26153 OATE
R�'r+Fng Lr,#CCCQ•129T9 6568 2nd AVEMIE
L.rTSw!•8ax'4tt•h�:urvsl FRANN�1riCKINNEY �O ��. fl.. 34474
�.r:rN�;arshr=!droof'rng.com � �•3so�aie�iroaa�g.w.T PMQNE (352) 854-4612 ���/�
FAX (3g2) 854—gg23
SS.MR11Q9 PITCH BREAK FLASHiNG/ROOF PENETRATI4N DETAII
5 RIBBED R�F PANEL
#9 X 2'WOOD ZAC
1'X 1'CLOSED CELL FOAM CLOSURE
( #9 X 2'WOOD ZAC
PITCH BREAK FLASHUVG MATERIAI.
NOTCHED TO FlT OVER RIBS OF PANELS
FASTENED ON TOP UF EACH kilGH RIB�9'O.C.
i 5 RIBBED ROOF PANEL
CROSS SECTION OF TYPICAL PlTCH BREAK CONNECTION
SSMR1110 „�„��oN�,�
DECKTITE GRAY ROUNO EPDM PIPE FLASHING
1'WIDE BUTYL SEALANT TAPE
#9 X 2'WOOD ZAC FASTENERS�1'O.C.
.
.
�' • •' GALVALUME pwq�T
VE(VT
�' 21/2'WIDE TRIPLE BEAD
-- _ BUTYt TA(�SEALANT
TITEBOND MEfAI ROOF
SEALANT(TUBE TYPE)
5 RIBBfD ROOF PANEL ISOMETRIC VIEW OF ROOF PENETRATION AT VENT
NOTES:
1. APPLY 1'WIDE DOUBlE BEAD BUM TAPE SEAt.ANT AROUND FWyGE OF VENTItATi01V p{pE
fLASHING,FASTENED TO ROOF USING#9 X 2'WOOD ZAC SCREWS 1'O.C.
2.APPIY 21/2"WIDE TRIPLE BEAD BUM TAPE SEALANTAROUND fLANGE pF p(fUyUST VENT
3.APPLYTUBE TYPE TITEBpIVD META�ROQF SEALANTAT FIASHING AND PANEL 1UNCTIpN
� i �er cat�r nt�r n�is�w �wo
_�''�Il -� �.t.�1 SE 53rd Avence TYPICAL Sf'EpFlCAlI0N5 YIE'RE pREpAREp BY AIE OR
��r I � 3. ��� � p o�,r-,o�a:s�:ao DETAiI �o�""r �swN �wo carPUEs
��� �����'�,� ����'� x�n� ,o � eunowc
:•� r
�;� Cee(813)299-1773
,,,� Fax f352j 2JT-5�02
Crner,�ll�c�rGGCO�55+S2 �•�='S-99&33Zd PAGE
�?anf�Lc.;CCCps28n! R J ADY P.E, �t 26 ATE
L c�,seci•eo.^�5d•��urr�,l 6568 S. d AVE?rUE
FRANK k9CKINNEY 11 �CALA, fC. 34474 ��p�h
- :ncu�:ar�trie:droofing.ccm � �gso�;siee!�xoormg.ccr P�K� (352) 85�-8612 O G•
FAX (352) 854-8923
Pasco County Parcel: 34-25-21-0170-00000-2350 001 Page 1 of 2
Data Current as Of: Weekly Archive - Saturday, May 11, 2013
Parcel ID 34-25-21-0170-00000-2350 (Card: 001 of 001)
Classification 02 - Mobile Homes
Mailing Address Property Value
JEFFERIS CHARLES E & Ag Land �o
JONES CARLA M Land �z3,oz5
7712 KAY MARIE AVE Building �55,0��
ZEPHYRHILLS FL 33541-7722
Physical Address Extra Features �i,541
7712 KAY MARIE AVE )ust Value ;90,643
ZEPHYRHILLS FL 33541-7722 ASS2SSeCi (Non-School Amendment 1) $90,643
Leqal Descriution (First 4 Lines)
See Plat for this Subdivision Taxable Value �0
GRAND HORIZONS - PHASE THREE
PB 53 PG 120
LOT 235
OR 8642 PG 2534
Land Detail (Card: 001 of 001)
Line Use Description Zoning Units Type Price Condition Value
1 0200 MSUBM OOM1 6,000.00 SF $3.75 �1.-00 1 $22,500
�L��
2 0200 MSUBM OOM1 954.00 SF $0.55 1.00 $525
���
Additional Land information
Acres 0.16 Tax Area 30ZH FEMA �Residential Code GDHZLPI
Code C�
Buildina Information - Use 02 - Mobile Home (Card: 001 of 001)
Year Built 2006 Stories 1.0
Exterior Wall i Above Average Exterior Wall 2 None
Roof Structure Gable or Hip Roof Cover Asphalt or Composition Shingle
Interior Wall i Drywall Interior Wall 2 None
Flooring 1 Sheet Vinyl Flooring 2 Carpet
Fuel Electric Neat Forced Air- Ducted
A/C None Baths 2.0
Line Description Sq. Feet Repl. Cost New
1 BAS 1,269 $62,993
2 FOA 48 $596
3 FST 96 $2,135
4 FEA 144 $6,056
5 FCA 420 $4,170
Extra Features (Card: 001 of 001)
Line Description Year Units Value
1 DWC 2006 378 $g27
2 CAC-4 2006 � 1 $714
Sales History
http://appraiser.pascogov.com/search/parcel.aspx?sec=34&twn=25&rng=21&sbb=0170&b... 5/17/2013