HomeMy WebLinkAbout13-14391 CITY OF ZEPHYRHILLS
, + 5335-8TH STREET
(813)780-0020 143,,9'(`�
BUILDING PERMIT �
Permit Number: 14391 Address: 6466 BRENTWOOD DR
Permit Type: MECHANICAL ZEPHYRHILLS, FL.
Class of Work: A/C CHANGEOUT Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: BRENTWOOD FIRST ADDITION
Est. Value: Parcel Number: 04-26-21-0030-OOD00-0090
Improv. Cost: 4,045.00
Date Issued: 7/24/2013 Name: CRAWFORD, ANN
Total Fees: 60.00 Address: P.O. BOX 403
Amount Paid: 60.00 ZEPHYRHILLS FL 33539-0403
Date Paid: 7/24/2013 Phone:
Work Desc: A/C CHANGE OUT 3 TON RHEEM
r--,
� �
,�
�-�._
/
DUCTSINSULAT
FINAL ?-Z '�
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c)when extra inspection
trips are necessary due to any one of the following reasons: a)wrong address b) condemned work resulting
from faulty construction c) repairs or corrections not made when inspections calied d) work not ready for
inspection when called e) permit not posted on job site� plans not at job site g)work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this properry that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your properly. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications Must Accompany Application.All work shall be performed in accordance with
Ci Codes and Ordinances. NO OCCUPANCY BEFO C.O.
�
CONT CTOR SIGNA RE PERMIT OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
W� " � �- 1 HeaUrw 8 Air Corrdltlonlna
s � � PROPANE GAS Service Order/Proposal �al1a
� AND AIC INC. LASTS AND LASTS AND LASTS:
��ce 1988 813-782-501�
WORK ORDE�#-��EFtV 1'C�MAN 44�:�.�7 AF'R
Sales, Service & Installations r�H-r� �T I m� �;-r�F;�� �Ei i�: i � ��e i;�,
4441 Allen Rd. • Zephyrhilis, FL 33541 Tnw.���i �av �� �_
P�l"E T T 1�1E E='R�r,1 I SE L� �'�E�;' �°, 1� k'�k'���4�
NOTES GLJSTCIME R#J I..QCAT I QN i 9481
�'HOI�E# �?7. _,-._l��:=� , .�;�=�.:i.
. ROUTE/SEG? �F�Rv:,��,54�:
. �
rRAW�QRD, AI�I�J ��RF�W�nh��, Ardf�l
�'. 0. ROK 4�3 � 64�� BREhITW00I? D�t
�1.L kl E�' 0 t�k��.��
ZEF'HYRHILL� FL. �,aS�� ZEF'HTf�HIi�L.� ��.a3`;4�:
rHEC�; UN I T, F�OSS I HLE �.ST t MATE TO C�EF�i. �"���F� �`aC.
C���£tiP'tY+�!C3P W4R#f Q'TY. MAT�R{AtS&SERVICES l�ld1T�"R1GE AMQklNI"
� � �
� � �
�✓ p T � �
�
� �
�y 5 � �2 � 3 s
�
� �
' N .� ' � �
c T ,.v ,s ZS4�°° c"'00;�
� �
� �
RECD�fMEN�ATtONS ' '
. i i
Aitttuat MBintertaece tdecommentfeci by AIJ Equiprt�er►t hlanufacturer5. Pressures Lo _HI T-Stat � �
i i
REFRIGERANT R- LBS. i i
FILTERS , a Changed Monthly I I
FILTERS + , Changed Monthly � /y��
� REGULAR �WARRANTY TOTAL SUluNa1ARY
Dehumidistat Settings: When here"t�", When Away�Q°(s,, T-Stat�Q° ❑ MAINTENANCE CONTRACT
SERVICE i
UMITED WARRANTY: All materials,parts and equipment are warranted by the manufacturers' METHOD OF PAYMENT CALL i
or supphers'wriflen warranty only.All labor performed by the above named company is warranted for i
Y 9 P Y O CASH ❑CK# TOTAL
30 da s or as otherwise indicated in writin The above named com an makes no other warranties, i
express or implied,and its agents or technicians are not authorized to make any such warran�ies on MATE RIALS
behalfofabovenamedcompany. ❑DEBIT '�CREDIT �OTHER MAINTENANCE �
I have authonty lo order ihe work outlmed above wNC�has been satisfactonly completed.I agree that Seller PROG. W I C �
retains Utle to eqwpmentlmaterials fumished unhi final payment is matle If paymen�is not made as agree0, C��M# �e
seller can remove said epwpmentlmater�ais at Seller s expense Any Oamage resulhng from said removal shall � O� OD i O
not be the responsibility of Seller NET 30 DAYS A 1 1l2%SERVICE CHARGE WILL BE ADDED MONTHLV TO
ALL UNPAID BALANCES OVER 30 DAYS NO REFUNDS DATE COMPLETED
TECH TAX
(/Ki n
CUSTOMER SIGNATURE DATE �/7CCC/II5 ���(� TOTAL Q TS'0`�
�
a�saeo-oo2o City of Zephyrhilis Permit Application Fax-813-780-0021
Building Department
Date Received Z Phone Contact for Permittin � �8 Z -- �✓
Owner's Name � C 99 w�Gl�Z Owner Phone Number
Owner's Address E��8 FwT �/lX� Owner Phone Number �— �
Fee Simple Titleholder Name Owner Phone Number �
Fee Simple Titleholder Address
JOB ADDRESS s'Qwl LOT# C�
SUBDIVISION PARCEL ID*
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED e NEW CONS7R 8 ADD/ALT Q SIGN Q Q DEMOLISH
INSTALL REPAIR
PROPOSED USE Q SFR Q COMM Q OTHER
TYPE OF CONSTRUCTION Q BLOCK Q FRAME � STEEL Q
DESCRIPTION OF WORK �/�— �/Sr� �(/�'/
BUILDING SIZE 361 FOOTAGE� HEIGHT ��
QBUILDING S VALUATION OF TOTAL CONSTRUCTION
DELECTRICAL a AMP SERVICE � PROGRESS ENERGY Q W.R.E.C.
QPLUMBING a
MECHANICAL $ O�s c+� VALUATION OF MECHANICAL INSTALLATION
�GAS Q ROOFING Q SPECIALTY 0 OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA QYES NO
BUILDER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License#
ELECTRICIAN COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License# �
PIUMBER � � COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License#
MECHANICAL ���_ COMPANY !3/�l� � ��o qw � c L
SIGNATURE REGISTERED Y/ N F E CURRE� Y/N
Address License# �ACL7 3
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License#
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set oi Energy Forms;R-O-W Permit for new construction,
Minimum len(10)working days after submittal date. Required onsite,ConstrucGon Plans,Stormwater Plans w/Silt Fence installed,
Sanitary FaciliHes&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(3}complete sets of Buflding Plans plus a Life Safety Pag�+;(�)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities 8�1 dumpster.Site Work Permit for all new projects.All commercfal requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
'""'PROPERTY SURVEY requfred for alf NEW construction.
Directions:
Fill out application completely.
Owner 8 Contractor sign back of application,nota�ized
if over 52500,a NoNce of Commencement la requlred. (A!C upgradea over 57500)
" Agent(for the contractor)or Power of Attomey(for the owner)would be sameone with notarized letter irom owner authorizing same
OVER THE COUNTER PERMITTING (Front of Application Only)
Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoVSurvey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions"
which may be more restrictive than County regulations. The undersigned assumes �esponsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and Ioca) regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be clted for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsibie. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansio� of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "ce�tificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Const�uction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", i certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with ali applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
ce�tify that 1 understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencles include but are not limited to.
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, WateNWastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fi�l:
- Use of fill is not allowed in Flood Zone"V"unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill materiat is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of�II is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an englneered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set fo�th in
this a�davit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a ticense to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building OfFicial from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH O R LE DER R AN ATTORNEY BEFO E RECORDING YOUR NOTICE OF CO ENCEMENT.
FLORIDA JURAT(F.S. 117.0 �
OWNER OR AGENT
,� -- CONTRACTOR� �
Subscrtbed and swom to(or rmed)before me thls Subscribed and s o(or affirmed)before me this
by r�3U`�'� by
Who is/are personally known to me or has/have produced Who Is/are personally known to me or haslhave produced
as idendficatlon. as identificaGon.
Notary Public Notary Public
'� Commission# f�40520
Com fs n '*
Commission No. f ,
��'6�,P,��.�� BorKkd Tlru Trc,y i:�in insuaixe BQO-�8S7019
Name of Notary typed,printed or stamped Name of Notary lyped,p n or s mp
� � � � PROPANE GAS
� AND A/C tn�c
�'rcE� �488 8 i 3-782-5013
-1-�-1 i �;;�11 1Zc�a.j /�E,i��i�h��i,. 1 l ;;;-�1
DtiCT SEAL AFFtDAVIT
Job Name C���(�e�W _ I,icense # C'AC'0���)48
Address _� 74?cP /��'P�nJ�Gc10t�� Perrl�it # / 7� /A
- - -- � _� ___ __���`��{
� �
-- - -�_p�--� o�at---33���
Phone O ��°' �g�" �� /�
1, c,('�U//� J�1/��/e__ _____ . affiant. herby aftirm that 1 am the at►uy licensed
contractor of record ior the ab<��c rcterenced permit, that all of the tor�o�ng intormation is tru�
and accurate, and that the duct sealin� at the ahove rctcrenced address has heen cc�mpleted �n
accordance with all applianc� codes and standards with•
L� Mast�c 'I ape Mastic
Contractor�s Name (pi-inleci) - �� '�. I.��il/ ��9/�� Date _� ��s
Signature
���r— _-------_.�-- -- -- --
� � � Des ig nStar Load Calcu lation
Results are intended for use w�th Rheem heating and cooling systerns
f+�tvew Dag+er �°C,<,m�,�r^'
� � � � �
Street Address 6466 Brentwood, Zephyrhills, FL 33542
Latitude, Longitude 27.9961°, -82.582°
House Square Footage: 1560 sq. ft.
Name: Ann Crawford
Phone: 813-782-7394
Email: example@mail.com
• ' • . •
SH R .75
Number of residents 2
Ceiling height 9
Wall U-value � R-value 0.09 � 11
Floor U-value � R-value 0.2 � 5
Ceiling U-value � R-value 0.053 � 19
Window U-value 0.5
Window SHGF 0.85
Moisture grains 56
Duct loss % 10
Duct gain % 10
Cooling infiltraction (ACH) 0.6
Heating infiltration (ACH) 0.8
Winter ventilation 0
Summer ventilation 0
� - • � • •
Outdoor Heating Cooling
Dry bulb (°F) 40 91
Daily range M
Relative humidity 50%
Moisture difference 56
Indoor Heating Cooling
Indoor temperature (°F) 70 75
Design temperature difference(°F) 30 16
� . • � . •
Area Btuh % of load
Wall 3234 14.6
Floor 5376 24.2
Cei I i ng 2480 11.2
Windows 3360 15.1
Infiltration 5745 25.9
System Efficiency Loss 2020 9.1
Total: 22215
Heating Loads
:;,
r System Efficiency Loss
/
Infiltration�
� �Ceiling
�Wall
Floor J \
`Windows
• • • • � •
Area Btuh °� of bad
Wail 2803 8.6
Ceiling 4217 12.9
Windows 12185 37.3
Sensible Infiltration 2298 7
Latent Infiltration 4972 15.2
System Efficiency Gain 2648 8.1
Internal 2652 8.1
Sensible People Load 460 1.4
Latent People Load 460 1.4
Total: 32695
Sensible load 27263
Latent load 5432
SH R 0.83
Capacity at .75 SHR 3.03 Tons
Cooling Loads
� ,, ; -�
Sensible People Load
��Latent People Load
`---Sensible Infiltration
�System EfficiencyGain
Windows �
--__Internal
�-Wall
/ `Ceiling
Latent Infiltration J
. � � — � � � • • � � �
AED Graph
is000
i0000
�
�
�
�
s000
� 8am 9am l0am llam 12pm lpm 2pm 3pm 4pm Spm 6pm 7pm Spm
— Houriy Loads —Average
� � � � � .
System ec�uipment selection wi11 be made using the following derived values
Glass (E) 113 sq. ft.
Glass (5) 16 sq. ft.
Glass (N) 16 sq. ft.
Glass (W) 79 sq. ft.
Summer Outdoor 91°F
Summer Wet Bulb 77°F
Summer Indoor 75°F
Summer Design Grains 50%
Winter Outdoor 40°F
Winter Indoor 70°F
Sensible Cooling 27,263 Btuh
Latent Cooling 5,432 Btuh
Required Cooling Airflow 1,239 CFM
Sensible Heating 22,215 Btuh
Required Heating Airflow 289 CFM
All calculations are based upon approved hvac industry standards and procedures,and comply with all local,
state and federal code requirements.Ali computed results are Estimates Product provided by Energy Design
Systems and Idea Tree