HomeMy WebLinkAbout13-14495 CITY OF ZEPHYRHILLS
- 5335-8TH STREET
� ' (sis)�so-oo20 14495
BUILDING PERMIT
Permit Number: 14495 Address: 7242 APPLEGATE DR
Permit Type: MECHANICAL ZEPHYRHILLS, FL.
Class of Work: A/C CHANGEOUT Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: ALPHA VILLAGE
Est. Value: Parcel Number: 35-25-21-0050-5000-0120
Improv. Cost: 7,286.00
Date Issued: 8/29/2013 Name: CURLEY THOMAS 8� MARY BETH
Total Fees: 75.00 Address: 7242 APPLEGATE DR
Amount Paid: 75.00 ZEPHYRHILLS, FL. 33540
Date Paid: 8/29/2013 Phone: 813-782-1621
Work Desc: A/C CHANGE OUT 3 TON 13 SEER
A 75.
�
�
DUCTS INSU�TEQ�
FINAL �
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80(2)(c)when extra inspection
trips are necessary due to any one of the following reasons: a)wrong address b)condemned work resulting
from faulty wnstruction c) repairs or corrections not made when inspections called d)work not ready for
inspection when called e) permit not posted on job site� plans not at job site g)work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before rec;ording your notice of commencement."
Complete Plans,Specifications Must Accompany Application. All work shall be performed in accordance with
Ci Codes and Ordinances. NO OCCUPANCY BEFO C.O.
ONT CTO SIGNATURE PERMIT OFFI R
PERMIT EXPIRI IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
AUG.30.2013 14:42 #3818 P.002 /004
gppg Jet Port Industrial Blvd
Tam pa, Fl 33634
Phone:813-�445-4818
Web:www.comfortiscool.com
services
Date: July 26 , 2013
The City of Zephyrhilis
5335 8th Strest, Zephyrhills, FL 33542
Subject:Authorization Letter far HVAC Mechanicai
Ger�tlemen:
I, Marek Stroz , autharize the following individual ( s )to pick up and sign permits on my
behaif
Mary Stewart
Bl2�ke Lanier
Edward 8erry
Dan Petro
Should you have any questions, Catl 813-445-4818
Sincerely
��� ��
A1 Y � ..�.-+r...:
0 �'`� ����+�
Mar#c Stroz �""�,'s�20Uiei�,,,,
aaaw,M+NOa�r
State Of Florida
Caur�#y of Hillsborough
The faregoing instrument was.� knowledge before me this t�day of
20,�_by ('� ' � `� who did not take an oath and wh has
produced id i 'on, vers License# a ~
My Commi ion exp s _ �t�I �� �--
N Signature
��
Tel: 813-445-4818
Tel: 727-495-7474
P RO POSAL Tel: 352-458-4181
2 3 8 8 Tel: 863-z2s-5588
s e r v i c e s www.andservices.com
Air Conditioning • Plumbing • Electrical contactCa�andservices.com
Installation Date.�/�� /� CAC 1818819,CFC-1428695,EC-13002594
Customer namee-��� h Date. � ��)1
G J
Street address of job location.� � � � � City� �, � FL Zip:2 ' �
7
Primary phone j . -- g�— 6"Z,) Other phone. Email:
� Factory-matched Heat Pump System ❑ Factory-matched Air Conditioning System ❑ Factory-matched Gas Furnace System
❑ Optimum # ❑ Premium # �( Deluxe # ❑ Economy #
✓ Up to 20 SEER ✓ Up to 16 SEER ✓ Up to 14 SEER ✓ 13 SEER
✓ 10 Year All Part ✓ 10 Year All Part ✓ 10 Year All Part ✓ 10 Year All Part Warranty
� Compressor Life Time Warranty ✓ 10 Year Compressor Warranty ✓ 10 Year Compressor Warranty ✓ 5 Year Compressor Warranty
� • � • • - • O Rotobrush duct cleaning S�ipply& Returns
� Whole House Biologic3 UV Sterilization System Stg. � ❑ Whole House Biologic3 Electronic Filtrations System
� • • • • • ' •
❑ Replacement ❑ Add-on Air Conditioning/HeaUBoth ❑ Replacement ❑ Add-on Air Conditioning/Heat/Both
�jl Air Handler/Furnace ❑ Vertical � Horizontal '�Cl +ieat Pump ❑ Air Conditioner ❑ Package Unit
� New Digital Thermostat� Non-Program ❑ Program. �( 3 tons �� SEER _ BTUH
❑ New Digital Programmable Therm with Humidity Control � Model W
❑ Relocate from to � Hurricane Pad ❑ Plastic Pad
❑ ❑ Relocate from to
❑ New AHU Stand ❑ Metal❑ Custom ❑ New safety disconnect switch
❑ Filtration ❑ Permanent Washable Filter ❑ Grille ❑ New 100% copper, dehydrated refrigerant piping
❑ New safety disconnect switch ❑ Surge Protection ❑ Fully insulated suction piping
❑ New wire from breaker panel to equipment ❑ New water tight electrical whip
❑ VenUFlue ❑ Complete new ❑ Use existing ❑
1 � � ' . . �
❑ Engineered duct system for tons vents ✓ All labor
❑ Economy ❑ Anti-Microbial $ ✓ Obtaining permits(where require�d)
❑ NON-FIBERGLASS-100% Rust Resistant Galvanized Sheet� `� New A/C circuit protection Brand =
Metal Duct System Energy Saving Insulation Included Existing size is / Change to !
❑ Rooms requiring additional airflow� ✓ Heating and Cooling routine maintenance for�_years
❑ New supply vent to ✓ Check entire system for safety a�nd efficiency
❑ New return vent to ✓ Shoe covers, mats and drop cloths to be used as necessary
❑ ✓ Remove existing equipment from premises
� Mastic and seal all leaking joints �j' ✓ Clean up
❑ Duct Sanitizing
• • • � � ' ' �
� 24-Hour Fix lf or Hotel Guarantee: Unlike most companies,we are a service company We have a staff of qualified service technicians that
are there to serve you in the unlikely event your system has a problem.So our guarantee to you is that when we arrive,we guarantee that we will
have your system up and running within 24 hours of our arrival or we will put you up in the local Embassy Suites far the night.
� Best Value Guarantee: Anyone can make something cheaper by cutting corners and pricing it for less.So,it's important to know what is and
is not included in any heating and cooling system you choose for your home.Our Best Value Guarantee is our promise to you that you cannot find
a comparable installation for less or we'll pay you a $50 00 bonus over the difference. All we ask is that it be a "published apples-to-apples"
comparison,within 14 days of purchase,and have the same written installation specifications as AS
� Instal/ation Workmanship Guarantee: Our installation technicians are the best in skill, attitude and workmanship They'll care for your
home and complete the job with speed and precision.They wear floor savers,clean up when they are finished anci take personal responsibility for
your satisfaction. They will not smoke or swear in your home and they are polite and courteous. If, when they h:3ve finished in your home,they
have not performed in accordance with these high standards,we'll refund whatever amount of the purchase price you feel to be fair All we ask is
that our office be notified of any level of dissatisfaction before the technicians leave the home so that any issues can be addressed accordingly
� EzClusive "NO Lemons" Guarantee: If the Compressor(the heart of your system)in your Air Conditioner Fails during the first five years of
ownership we will remove the entire outside unit, rather than the component, and install a completely new one, if you've ever bought a "lemon"
before,you truly appreciate our commitment to your long-term satisfaction.
� No Mold Guau'antee: We are so confident in the Biologic3 UV Sterilization&Electronic filtration systems ability to keep your system clean that
we guarantee with proper annual maintenance your system will be mold free for life or we will perform any necessary cleaning to the air handler to
remedy the problem at our expense.
• ' • •
Total Investment $ ��.�p (-) Rebates$ (-) Service Repair Refund$
Net Total Investment After All Discounts Including Power Company& Manufacturer rebates$���,0�
This High Efficiency Hom omfort System is available with 100% bank financing with no money down lfor $ per month
(with approved credit)
AS Representative A l�)� � Date of proposal � /��/ 13
Customer agrees to provide free access to the work area and a safe working environment.The above prices,specifications,tertns,and conditions are satisfactory and hereby agreed to in full
1 give authonzation to order aforementioned work.You are authoraed to do the work as specfied.Payment will be made as outtined I understand that you are not responsible for events or delays
beyond your control Owner agrees to carry adequate fire,atortn,and other necessary insurance.All of our workers/work is covered by Workman's Compensahon and a Two Million General Liability
Insurance If collection is necessary,buyer agr s to pay all collection costs and interest.
CustomerApproval �� Date O / �C'� / (�
~m19 nd ServicesT'"
` -a
c�J,c �,c. v � -c
Curley Residence
HVAC Load Calculations
for
Tom Curley
7242 Applegate Drive
Zephyrhills, FI 33540
����� H�AG L�
Prepared By:
Blake Lanier
And Services
6008 JETPORT INDUSTRIAL BLVD
TAMPA, FL, 33634
813-445-4818
Monday, August 26, 2013
Rhvac is an ACCA approved Manual J and Manual D computer program
Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
'�.
'vi������!Ki r� �'� �'.i�;•''i: '� � . ��
.�}�`'�AiR�: '3°�"`•' � $
Project Report
� Project Title: Curley Residence
Designed By: Blake Lanier
Project Date. Aug 26th 2013
Client Name� Tom Curley
Client Address. 7242 Applegate Drive
Client City: Zephyrhills, FI 33540
Client Phone: 813-782-1621
Company Name: And Services
Company Representative: Blake Lanier
Company Address: 6008 JETPORT INDUSTRIAL BLVD
Company City: TAMPA, FL,33634
Company Phone. 813-445-4818
Company E-Mail Address: OFFICE@COMFORTISCOOL.COM
Company Website: WWW COMFORTISCOOL.COM
Reference City: Tampa, Florida
Building Orientation: Front door faces Southeast
Daily Temperature Range: Medium
Latitude: 28 Degrees
Elevation• 19 ft.
Altitude Factor: 0.999
Elevation Sensible Adj. Factor: 1.000
Elevation Total Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Elevation Heating Adj. Factor: 1.000
Outdoor Outdoor Outdoor Indoor Indoor Grains
Drv Bulb Wet Bulb Rel.Hum Rel.Hum Dr Bul Difference
Winter: 40 37.52 80% n/a 70 n/a
Summer: 95 77 45% 50% 75 46
. ,.
Total Building Supply CFM: 1,327 CFM Per Square ft.: 1.171 *
Square ft.of Room Area: 1,134 Square ft. Per Ton. 325
Volume(ft3) of Cond.Space: (clg.) 9,072
` Based on area of rooms being heated or cooled (whichever governs system) rather than entire floor area.
Total Sensible Gain: 33,912 Btuh 81 %
Total Latent Gain: 7,908 Btuh 19 %
Total Cooling Required Including Ventilation Air: 41,820 Btuh 3 48 Tons(Based On Sensible+ Latent)
,,1
Rhvac is an ACCA approved Manual J and Manual D computer program
Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\UsersWaosn\Desktop\ELITE�ACEVEDO.rhv Monday,Aiagust 26,2013, 11:53 AM
. �����
,�,�<r�,V`��°�. :�:�' .,: - ' • C�'�
fi�� N��'`�.��
Miscelianeous Report
� �: °'- �r � � �S
; '"� , ,��a , . ;� ,';: � .
,. _ . � F�et:�n �t.l� �8t�b D
Winter: 40 37.52 80% n/a 70 n/a
Summer: 95 77 45% 50% 75 46.41
�
Main Trunk Runouts
Calculate: Yes Yes
Use Schedule� Yes Yes
Roughness Factor: 0.00300 0.01000
Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft.
Minimum Velocity: 650 ft./min 450 ft./min
Maximum Velocity: 900 ft./min 750 ft./min
Minimum Height: 8 in. 8 in.
Maximum Height: 8 in. 8 in.
Winter Summer
Infiltration Specified: 0.000 AC/hr 0.230 AC/hr
0 CFM 35 CFM
Infiltration Actual: 0.000 AC/hr 0.000 AC/hr
Above Grade Volume: X 0 Cu.ft. X 9.072 Cu.ft.
0 Cu.ft./hr 0 Cu.ft./hr
X 0.0167 X 0.0167
Total Building Infiltration: 0 CFM 0 CFM
Total Building Ventilation. 0 CFM 215 CFM
---System 1---
Infiltration&Ventilation Sensible Gain Multiplier: 21.98 = (1.10 X 0.999 X 20.00 Summer Temp. Difference)
Infiltration &Ventilation Latent Gain Multiplier: 31.54 = (0.68 X 0.999 X 46.41 Grains Difference)
Infiltration&Ventilation Sensible Loss Multiplier: 32.98 = (1.10 X 0.999 X 30.00 Winter Ter�'ip. Difference)
Winter Infiltration Specified: 0.000 AC/hr(0 CFM), Construction.Average
Summer Infiltration Specified: 0.230 AC/hr (35 CFM), Construction:Average
,. .. ....
��� y � • • � , �
� , , �, , , Duct D�t F►am
__ � � _
`n ;t� Le�kage � Area N�D
1 Supply Main Attic 166 0.12 6 112 No
1 Return Main Attic 166 0.24 6 112 No
C:\UsersWaosn\Desktop\ELITEWCEVEDO.rhv Monday,August 26,2013, 11:53 AM
�IM�r' .i�..
-,:a.y.�';' '_}��, , _..s.�. �_, ,, . .�.
.,:(e°.x� t' �k � ' .� � `fi�.,•,���,
Load Preview Report �
Net Rec ft2 Sen Lat Net Sen! Sys Sys Sys �t
Scope Ton Tm /Ton Area Gain Gain Gain Loss �9' C�g A� Size
CFM CFM CFM
Building 3.48 3.77 301 1,134 33,912 7,908 41,820 0 0 1,327 1,327
System 1 3.48 3.77 301 1,134 33,912 7,908 41,ffi0 0 0 1 327 1,327 32x
Vemilation 4,727 6,781 11,508 0
Duct Latent 727 727
Zone 1 1,134 29,185 -tOG 29 585 0 0 1 32- 1,327 32x
1-Ist Floor 1,134 29,185 400 29,585 0 0 1,327 1,327 13--
C:\Users\Jaosn\Desktop\ELITE�ACEVEDO.rhv Monday,August 26,2013, 11:53 AM
. �:��
,„��,-�1�a: , �,� -; �.
' '.�.4�i- 'J+..'.�,! i�
Total Building Summary Loads
.�r� � <'� � .�: �
,�'' �ea � t,� Ser► To�l1
.
� ,
� � � . �., ,;
,
rr. �._� _' " r�.� , ' C�Bn !.� 8�ii� G�irt E�dt�
iC-cm: Glazing-Single pane windowwith storm, clear, 176 0 0 13,185 13,185
metal frame no break, u-value 0.87,SHGC 0.67
11 F: Door-Wood-Solid Core With Metal Storm 21 0 0 182 182
13A6-Ofcs:Wall-Block, no blanket or board insulation, 955 0 0 3,914 3,914
filled core,siding finish
16A-13: Roof/Ceiling-Under Attic with Insulation on Attic 1134 0 0 5,954 5,954
Floor(also use for Knee Walls and Partition Ceilings),
Unvented Attic, No Radiant Barrier,Any Roofing
Material,Any Roof Color, R-13 insulation
FLOOR ON SLAB: Floor-Over open crawl space or 1134 0 0 561 561
gara�e,Custom, FLOOR ON THE SLAB
Subtotals for structure: 0 0 23,796 23,796
People. 2 400 460 860
Equipment: 0 1,200 1,200
Lighting: 215 733 733
Ductwork: 0 727 2,996 3,723
Infiltration:Winter CFM:0, Summer CFM:0 0 0 0 0
Ventilation:Winter CFM:0, Summer CFM.215 0 6,781 4,727 11,508
Total Building Load Totals. 0 7,908 33,912 41,820
� ' _
Total Building Supply CFM: 1,327 CFM Per Square ft.� 1.171 `
Square ft.of Room Area: 1,134 Square ft. Per Ton• 325
Volume(ft3) of Cond. Space: (clg.) 9,072
* Based on area of rooms being heated or cooled (whichever governs system) rather than entire floor area.
Total Sensible Gain: 33,912 Btuh 81 %
Total Latent Gain: 7,908 Btuh 19 %
Total Cooling Required Including Ventilation Air: 41,820 Btuh 3.48 Tons(Based On Sensible+ Latent)
� t
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\UsersWaosn\Desktop\ELITE�ACEVEDO.rhv Monday,August 26,2013, 11:53 AM
� ,y�;��,, . , - , ��1��
xs� � E, :« �� �` �'��
E�"
System 1 System 1 Summary Loads
�-_ ,�;� ..,_: A� ;� l� S�er� T+�I
,�.�i' '+�» ; , :;_4 �
6"�•� �� '`•y,+t� tt'",��~����� �Y��R�� �W'Y ^�
�` � � �l,
iC-cm:Glazing-Single pane windowwith storm, clear, 176 0 0 13,185 13,185
metal frame no break, u-value 0.87, SHGC 0.67
11 F: Door-Wood-Solid Core With Metal Storm 21 0 0 182 182
13AB-Ofcs:Wall-Block, no blanket or board insulation, 955 0 0 3,914 3,914
filled core,siding finish
16A-13: Roof/Ceiling-Under Attic with Insulation on Attic 1134 0 0 5,954 5,954
Floor(also use for Knee Walls and Partition Ceilings),
Unvented Attic, No Radiant Barrier,Any Roofing
Material,Any Roof Color, R-13 insulation
FLOOR ON SLAB: Floor-Over open crawl space or 1134 0 0 561 561
garage,Custom, FLOOR ON THE SLAB
Subtotals for structure: 0 0 23,796 23,796
People: 2 400 460 860
Equipment: 0 1,200 1,200
Lighting. 215 733 733
Ductwork. 0 727 2,996 3,723
Infiltration:Winter CFM:0, Summer CFM:0 0 0 0 0
Ventilation:Winter CFM:0, Summer CFM:215 0 6,781 4,727 11,508
System 1 System 1 Load Totals: 0 7,908 33,912 41,820
a ..: .
Supply CFM: 1,327 CFM Per Square ft.: 1.171 `
Square ft. of Room Area: 1,134 Square ft. Per Ton: 325
Volume(ft3) of Cond. Space: (clg.) 9,072
` Based on area of rooms being heated or cooled (whichever governs system) rather than entire floor area.
i � �.Pi'= a' . .
Total Sensible Gain• 33,912 Btuh 81 %
Total Latent Gain• 7,908 Btuh 19 %
Total Cooling Required Including Ventilation Air: 41,820 Btuh 3.48 Tons(Based On Sensible+ Latent)
. ..
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users�.laosn\Desktop\ELITE�ACEVEDO.rhv Monday,August 26,2013, 11:53 AM
1 �(y��,�,y�� ����
_N,.��r�'-.w. . �,r . . �^"^J � �
'�[-.��'"�'.N us%r'�` xfft�a,. � �
System 1, Zone ) Summary Loads (Average Load Procedure for Rooms)
t y;=�:,Y�a�tAt: °:-` ` � t„� S� T+�+at1
'"��� :���� �r' Clt�tt i_� Q� C�in
1C-cm. Glazing-Single pane windowwith storm,clear, 176 0 0 13,185 13,185
metal frame no break, u-value 0.87, SHGC 0.67
11 F: Door-Wood - Solid Core With Metal Storm 21 0 0 182 182
13A6-Ofcs:Wall-Block, no blanket or board insulation, 955 0 0 3,914 3,914
filled core,siding finish
16A-13: Roof/Ceiling-Under Attic with Insulation on Attic 1134 0 0 5,954 5,954
Floor(also use for Knee Walls and Partition Ceilings),
Unvented Attic, No Radiant Barrier,Any Roofing
Material,Any Roof Color, R-13 insulation
FLOOR ON SLAB: Floor-Over open crawl space or 1134 0 0 561 561
garage,Custom, FLOOR ON THE SLAB
Subtotals for structure: 0 0 23,796 23,796
People: 2 400 460 860
Equipment: 0 1,200 1,200
Lighting: 215 733 733
Ductwork: 0 0 2,996 2,996
Infiltration:Winter CFM:0, Summer CFM.0 0 0 0 0
System 1,Zone 1 Load Totals: 0 400 29,185 29,585
`_ _ _` . � �"
Supply CFM: 1,327 CFM Per Square ft.: 1.171 *
Square ft. of Room Area: 1,134 Square ft. Per Ton� 460
Volume(ft3) of Cond. Space: (clg.) 9,072
' Based on area of rooms being heated or cooled (whichever governs system) rather than entire floor area.
4"�+��_ '" �8`_ _
Total Sensible Gain: 29,185 Btuh 99 %
Total Latent Gain: 400 Btuh 1 %
Total Cooling Required. 29,585 Btuh 2.47 Tons(Based On Sensible+ Latent)
� "
Rhvac is an ACCA approved Manual J and Manual D computer program
Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
All computed results are estimates as building use and weather mayvary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\Jaosn\Desktop\ELITEWCEVEDO.rhv Monday,August 26,2013, 11:53 AM
, . �de����
.�.,
:�,`;�` � . r. �`.
Detailed Room Loads - Room 1 - Ist Floor (Average Load Procedure)
. .I:y;' , , .: , � .
Calculation Mode• Clg. only Occurrences: 1
Room Length: 42.0 ft. System Number� 1
Room Width: 27.0 ft. Zone Number: 1
Area: 1,134.0 sq.ft. Supply Air: 1,327 CFM
Ceiling Height: 8.0 ft. Supply Air Changes: 8.8 AC/hr
Volume: 9,072.0 cu.ft. Req.Vent. Clg: 215 CFM
Number of Registers: 13 Actual Winter Vent.: 0 CFM
Runout Air: 102 CFM Percent of Supply• 0 %
Runout Duct Size: 8 in. Actual Summer Vent.: 215 CFM
Runout Air Velocity: 293 ft./min. Percent of Supply: 16 %
Runout Air Velocity: 293 ft./min Actual Winter Infil.: 0 CFM
Actual Loss: 0.038 in.wg./100 ft. Actual Summer Infil.: 0 CFM
�r� -U- h#� S�en GI� Lat S+�n
V�:+e H'�M Lo�.s HTAA Gain Gair7
N -Wall-13A6-Ofcs 40 X 8 275 0.183 0.0 0 4.1 0 1,127
E-Wall-13A6-Ofcs 32 X 8 134 0.183 0 0 0 4.1 0 549
S-Wall-13A6-Ofcs 40 X 8 320 0.183 0 0 0 4.1 0 1,312
W-Wall-13A6-Ofcs 32 X 8 226 0.183 0 0 0 4.1 0 926
N -Door-11 F 3 X 7 21 0.280 0.0 0 8.7 0 182
N -Gls-1 C-cro shgc-0.67 100%S(2) 24 0.870 0.0 0 31.4 0 754
E-Gls-1 C-cro shgc-0.67 0%S(2) 50 0.870 0.0 0 81.8 0 4,090
E-Gls-1 C-cro shgc-0.67 0%S(2) 72 0.870 0.0 0 81.8 0 5,888
W-Gls-1 C-cro shgc-0.67 0%S 30 0.870 0.0 0 81.8 0 2,453
UP-Ceil-16A-13 42 X 27 1134 0.070 0.0 0 5.3 0 5,954
Floor-FLOOR ON SLAB 27 X 42 1134 0 033 0.0 0 0.5 0 561
Subtotals for Structure. 0 0 23,796
Infil.:Win.:0.0, Sum.:0.0 1,152 0.000 0 0 000 0 0
Ductwork: 0 2,996
People:200 IaUper,230 sen/per: 2 400 460
Equipment: 0 1,200
Lighting: 215 733
Room Totals: 0 400 29,185
C:\Users\Jaosn\Desktop\ELITEWCEVEDO.rhv Monday,August 26, 2013, 11:53 AM