HomeMy WebLinkAbout13-14632 CITY OF ZEPHYRHILLS
5335-8TH STREET
- (sis)�so-oo20 14632
BUILDING PERMIT
Permit Number: 14632 Address: 38331 EUCALYPTUS DR
Permit Type: MECHANICAL ZEPHYRHILLS, FL.
Class of Work: A/C CHANGEOUT Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: DRIFTWOOD
Est. Value: Parcel Number: 02-26-21-0240-00000-0120
Improv. Cost: � 3,695.00
Date Issued: 10/16/2013 Name: ROESKE, JOHN & KATHLEEN
Total Fees: 55.00 Address: 38331 EUCALYPTUS DR
Amount Paid: 55.00 ZEPHYRHILLS, FL. 33542
Date Paid: 10/16/2013 Phone:
Work Desc: REPLACE HEAT PUMP
A , . 55.
�
DUCTSINSULATED
FINAL�I R�-�,�
REINSPECTlON FEES: Reinspection fees will comply with Florida Statute 553.80(2)(c)when extra inspection
trips are necessary due to any one of the following reasons: a) wrong address b) condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d)work not ready for
inspection when called e) permit not posted on job site f) plans not at job site g)work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications Must Accompany Application.All work shall be performed in accordance with
Ci Codes and Ordinances. NO OCCUPANCY BEFO C.O.
V �O?
CON R SIGNATURE PERMIT OFFI R
� PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
o i.s-iau-uutu C;ity of Zephyrhilis Permit Application Fax-813-780-0021
- Building Department
Date Received Phone Contact for Permittin --
Owner•s Name Vb �Q�-S,C�i Owner Phone Number
Owner's Address �� .3 .3 f �/ L " T v.5 s�L Owner Phone Number [
Fee Simple Titleholder Name Owner Phone Number r
Fee Simple Titleholder Addresa
JOB ADDRESS ��/t'� � ] LOT� �
SUBDNISION PARCEL ID#
(OBTAINED FROM PROPERTY TAX NOTICE)
INORK PROP03ED e NEW CONSTR 8 ADD/ALT [� SIGN Q Q DEMOLISH
INSTALL REPAIR
PROPOSED USE Q SFR Q COMM � OTHER �
TYPE OF CONSTRUCTION Q BLOCK Q FRAME Q STEEL Q
DESCRIPTION OF 1NORK K c� � ��'qj' ����
BUILDING SIZE SQ FOOTAGE� HEIGHT ��
OBUILDING a VALUATION OF TOTAL CONSTRUCTION
QELECTRICAL � AMP SERVICE 0 PROGRESS ENERGY Q W.R.E.0
QPLUMBING a
�CHANICAL � 3��y�0 0 VALUATION OF MECHANICAL INSTALLATION
/
�GAS � ROOFING Q SPECIALTY � OTHER
FINISHED FIOOR ELEVATIONS � FLOOD ZONE AREA QYES NO
BUtLDER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License# C �
EI.ECTRICIAN COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License# C �
PLUMBER � COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License# C
MECHANICAL COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License# C
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURRE� Y/N
Address License# C
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facllitles&1 dumpster;Site Work Permit for subdivisions/large proJects
COMMERCIAL Attach(3)complete sets of Buflding Plans plus a Lffe Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence instalied,
Sanitary Facilities 8 1 dumpster.Site Wor1c Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
""'PROPERTY SURVEY required for all NEW consUucdon.
Dircctions:
Fill out application completely.
Owner&Contractor sign back of appUcation,nota►ized
If over S2S00,a Notice of Commencement ia required. (A/C upgrades over E7500)
'• Agent(for the contractor)or Power of ABomey(for the owner•)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTINEi (�ront of Application Only)
Reroofs if shingles Sewers Service Upgrades A/C Fences(PIoVSurvey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"r�striction,s"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
cont�acto� is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what Iicensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Fu�thermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACTIUTILITIES IMPACI'AND RESOURCE RECOVERY FEES: The undersigned understands
that T�ansportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as spec�ed in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
finai power release, the fees must be paid prior to permit issuance. Furthermore, ff Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accorda�ce with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): if valuation of work is$2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Depa�tment of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"prior to commencement.
CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating constructio�, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the ju�isdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V"unless expressly permitted.
- If the fill material is to be used in Flood Zone "A°, it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGEN7 FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the pe�mit is suspended or abandoned for a period of six(6) months afte�the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and wilf demonstrate
justifiable cause fo�the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TINICE FOR fMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSUL7
lNITH YOUR LENDER AN TTORNEY BEFORE RECORDING YOU O C T.
FLORIDA JURAT(F S. )
OWNER OR AGENT CONTRACTOR
Subscribed and swom to(or ffirmed)before me thls Subs bed nd swom o(or rmed)bef r� e hls
by bY
Who islare personally known to me or has/have produced f rsonally kn o e o ia ve pr uced
as Idendficatlon. as identlfication.
''"��"'• Notary Public
Notary Public _ "-
Commissfon No. Commission o`� � ���#EE �
° eor�n �2016
n.o noyF,A,6.,,ri,o,'
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamp
' ��.�S �C�`j`� -(.3 /�1`�i'
� • . Heating 8 Air Conditioning
� � PROPANE GAS Service Order�Proposal aRa
AND AIC INC. LASTS AND LASTS ANO LASTS.
�7ce 19 813-782-5013 � `
,.�j���F� ��f:,��z-f'f�k -'�;F�R�! f['E"h1�-lr.� -+G�`a�: _T!.�hi
Sale Se 'ce & installations !�'�<��� `T �riE:- rr�h'�t� t��%4h�:�,� � _: :� _,: <+,-�
4441 Alle Rd, Zephyrhills, FL 33541 rf t� ��r�� �4� ��� t��
L�(����:i 7 1 IYI E_. f'F'c)P�I I�;E-_L,
NOTES f:I.)�:z'Tf7C�lf��F;i�P,`1. f�� �'i�l�I C]t'! t Fi4 t�'�r":,
r�t-�;_�r���t �,� � - �r;�--;,,��,,-. �-�
C[�r,TF=��,T F�ti�:;T[��1Ri:;
F'T'U�i� -�,F"C� )lJt�.i- hdf_�
I M�-i�' - f=i /I-! {-i�aE_ !_I.+!(3 i
.
��o�::�-�-•�:_, 7�:]�t i�J � �f?i i�:�,N;I=, _r r Fi r.i
:�,f3��,j. �i_If"t�L_��'�! U�> I:�f� :38.-��'.1 r'L1L_.F�L_�P-fU'� t;�,�
f)N 1 i=T't�lC?�'1ts�
?'!' �'Fi4'FI-�?'I. I �: � f �-- ' ?,�r��_� ?�!"�I-iYF.F�II_.I_�.; k=i =�:?`;4``
���f'�: C�F-!_.t'�•h�;ICi�:,�1l.hi._C� �1_.1cR�.t'�i�_a��`)��`_.�
I'-�',1�t MF�'l��-
DESCRIPTIOM OF WOFtt(,, Q'T'Y. MRTERiAIS&3ERVICES , UNIT PRiCE AM�UNT
- - - - -�- - - . .. _ � _ _ ___. _._ ._ ........_. .. .�.---- - __ _,__� a__
� . � � i i
' -� ` i
. � �. .
i �
� i
i i
�- i i
M I, � � �O
. � �
� �
, �� � �i' . r�
� i
� i
_ .�tu;� '�,.
RECOMMENDATIOFJS � � �
i i
nua ain nar�ce ecommen � anu rs. � �
Pressures Lo HI T-Stat i i
� i i
REFRIGER.4NT R- LBS. $per Ibs. � �
FIITERS . � Changed Mon[hly I I
FILTERS x . Changed Monthly � �
J REGULAR ❑WARRANTY TOTAL SUWIMARY
(�elwmK,iistat 58ttings: When here"ON", When Away fQJs, T-Stat$Q° U MAINTENANCE CONTRACT SERVICE i
LIMITED WARRANTY• NI materials,parts and eqwpment are warranted by the manufacturers' METH�D OF PA`lA+F�NT CALL i
or suppliers'wntten warranty only All labor performed by the above named company is warranted for TOTAL i
30 days or as otherwise indicated in wrifing The above named company makes no other warranties, ❑CASH !�CK# MATERIALS i
express or implied,and Rs agents or technicians are not authonzed to make any such warranties on
i
behalfofabovenamedcompany. ❑DEBIT �CREDIT ❑OTHER MAINTENANCE i
I have aNhonty lo ortler ihe work outlined above which has been satisfactoriN completeC 1 agree!hal Seller PF�OG. W � C
reta�ns title to equipmenUmaterials lurms�ed unnl final payment is made If payment is not matle as agreed. CLAIM$k
seller can remuve said equ�pmenf/materials at Sellers expense Any damage resulting trom saitl removal shall �
no�be Ihe responsibniry of Seller NET 30 DAYS A 1 V2"o SERVICE CHARGE WILL BE ADDED MONTHLY TO — •'yt►�t ]r� I/`y��
ALL UNPAID BALANCES OVER 30 DAVS NO REFUNDS DATE COMPLETED v `-°`�
TECH , T/� �
i
i
���r �c ✓�' - -- TOTAL ��� ' �
CUSTOMER SIGNATURE pq7E �i}"J Q((
�� �ti
y ���''�I �' �f;'�PANE GA��
:�-
' a�„�;� A/C �MC.
�� �-�82-501�
. , r . , , ' ;;;� �
DUCT SEAL AFFIDAVIT
Job Name �ol�i✓_�p£S�� License # CAC043'948
Address �� 3 3l__��/_C�L yjoTvS�� Permit# ___
-- /
i ��� �.✓oe�f7 `i��.,c� .S
Z� 1 ,- , ��_ _ �� �.�.5'f'�
Phone_��3 '— 7$ C� � ��1.��
I. fiant, herby affirm that I am the dully licensed
contractor of record for the above referenced permit, that all of the forgoing information is true
and accurate, and that the duct sealing at the above referenced address has been completed in
accordance with all appliance codes and standards with:
�Iastic "I,ape �-lviastic
Contractor's Name (printed) � v.''vv �, ,C� �0 �/� Date �� �8_��
Signature _
� � � Des ig nStar Load Calcu lation
Results are intended for use with Rheern heating and cooling systerns
T'w Nlew C�agr�o'G,�rm!�r^'"'
� � � � �
Street Address 38331 Eucaliptus Dr. Zephyrhills, Zephyrhills, FI_
33542
Latitude, Longitude 27.9961°, -82.582°
House Square 1160 sq. ft.
Footage:
Name: John Roeske
Phone: 33542
Email: example@mail.com
• ' • . �
SHR .75
Number of residents 2
Ceiling height 9
Wall U-value � R-value 0.09 � 11
Floor U-value � R-value 0.2 � 5
Ceiling U-value � R-value 0.053 � 19
Window U-value 0.5
Window SHGF 0.85
Moisture grains 56
Duct loss % 10
Duct gain % 10
Cooling infiltraction (ACH) 0.6
Heating infiltration (ACH) 0.8
Winter ventilation 0
Summer ventilation 0
� - • • • •
Outdoor Heating Cooling
Dry bulb (°F) 40 91
Daily range M
Relative humidity 50%
Moisture difference 56
Indoor Heating Cooling
Indoor temperature (°F) 70 75
Design temperature difference(°F) 30 16
� . • • . •
Area Btuh % of load
Wall 2860 16.4
Floor 4386 25.1
Ceiling 1844 10.6
Windows 2505 14.4
I nfi Itrati on 4272 24.5
System Efficiency Loss 1587 9.1
Tota I: 174 5 4
Heating Loads
, t;� .
�System EfficiencyLoss
Floor�
�Ceiling
'---Windows
Infiltration J �
Wall
• • • • . •
Area _ B#uh % of bad
Wall 2478 9.9
Ceiling 3135 12.5
Windows 9080 36.3
Sensible infiltration 1709 6.8
Latent Infiltration 3697 14.8
System Efficiency Gain 2010 8
Internai 1972 7.9
Sensible People Load 460 1.8
Latent People Load 460 1.8
Tota I: 25 001
Sensible load 20844
Latent load 4157
SHR 0.83
Capacity at .75 SHR 2.32 Tons
Cool i ng Loads
� ,, , ,
rSensible People Load
I �Latent People Load
�--Sensible Infiltration
�Intemal
Windows�
�--System Efficienc�
�Wall
Latent Infiltration J `Ceiling
♦ • ' • � ' • • ' � '
AED Graph
is000
i0000
� \�
�a
0
J
5�0�
� 8am 9am l0am llam 12pm lpm 2pm 3pm 4pm Spm 6pm 7pm 8pm
— Hourly Loads —Average
� � � � � �
System equipment selection wiil be made using the following derived values
Giass (E) 84 sq. ft.
Glass (S) 12 sq. ft.
Glass (N) 12 sq. ft.
Glass (W) 59 sq. ft.
Summer Outdoor 91°F
Summer Wet Bulb 77°F
Summer Indoor 75°F
Summer Design Grains 50%
Winter Outdoor 40°F
Winter Indoor 70°F
Sensible Cooling 20,844 Btuh
Latent Cooling 4,157 Btuh
Required Cooling Airflow 947 CFM
Sensible Heating 17,454 Btuh
Required Heating Airflow 227 CFM
All calculations are based upon approved hvac industry standards and procedures,and comply with all focal,
state and federal code requirements.All computed results are Estimates Product provided by Energy De�sign
Systems and Idea Tree