HomeMy WebLinkAbout13-14839 CITY OF ZEPHYRHILLS �
5335-8TH STREET
(sis)�so-oo20 14839
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
�, ,� «�, ���t. �-F �N�,a
�,� ;��.:.� ,��.� ,,.ti,w
.� <. �F : ,�„.,
Permit#:14839 Issued: 12/20/2013 Address: 37847 PRAIRIE ROSE LP LT 25
Permit Type: GENERAL BUILDING PERMIT ZEPHYRHILLS, FL.
Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 350,000.00 Total Fees: 8,386.31 Subdivision: WALNUT GROVE TOWNHOMES
Amount Paid: 8,386.31 Date Paid: 12/20/2013 Parcel Number: 15-26-21-0030-06600-0000
,, �,,,t � �;°
, , .
,. , �
�n�, .,�d P r.,., p�^" . � '�@ i a ��. ��. ' . ��
N, .. ,. ,�� , . : . . � . . .
Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME
Addr: 4209 GALL BLVD Address: 4034 GALL BLVD
ZEPHYRHILLS, FL 33542 ZEPHYRHILLS
Phone: (813)377-7395 Lic: Phone: (813)973-5250
Work Desc: NEW CONSTRUCT 4 UNIT TOWNHOME- 7007 SQ FT (#1 UNIT)-sif waived see emai
:.,:, i� :'��°<,t ;� 4.. �rm y '"i �' ; ",. � E }`,;.,. �m�#�-R�"� � <s��,:� �: �� , �a "'�:r 4"yr�£ ��.� �r, z.
...}si�;� .! ,e'a �r � �, 6� .��a �'. ,U�
UIL IN 330.69 �EL I AL F . � 46.41
MECHANICAL FEE 32.49 SEWER CONNECTION RESIDEN- 2,010.00 WATER CONNECTION RESIDENI 641.00
WATER METER RES 3/4" 348.09 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES TOWNHOMES 769.56 SCHOOL IMPACT FEE/UNITS 0.00
SCHOOL IMPACT FEE-sfr/1% 0.00 TRAFFIC IMPACT FEE 99% 3,445.20 TRAFFIC IMPACT FEE 1% 34.80
FIRE PLAN REVIEW FEES 105.09
` 1
� � � �
i
� �
i
� �� '����
Y' - r - *',�s� a '�... ,�„ y v � �+' 'fi k:,' ,� r � �. Y
, „ .
;.� �, k_=, �^' -*' ka., � ,,�i'r�. r �,X � +��'�'� ;ar1.
�F 2 D R U U � MI IN �ULATI
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80 (2)(c)when extra inspection
trips are necessary due to any one of the following reasons: a)wrong address b)condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d) work not ready for
inspection when called e) permit not posted on job site� plans not at job site g) work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this properly that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications and Must Accompany Application.All work shall be pertormed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
)
. f�\
CONTRACTORS SIG ATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
CITY OF ZEPHYRHILLS
5335-8TH STREET
�si3��so-oo20 14839
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
Permit#:14839 Issued: 12/20/2013 Address: 440 RT ST
Permit Type: GENERAL BUILDING PERMIT ZEPHY ILLS, FL.
Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: ange:
Proposed Use: NOT APPLICABLE Lot(s): Block: ection:
Sq. Feet: Est. Value: Book: Page:
Cost: 350,000.00 Total Fees: 8,386.31 Subdivision: CITY OF ZEPHYRHILLS
Amount Paid: 8,386.31 Date Paid: 12/20/2013 Parcel Number: 15-26-21-0030-06600-0000
Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME
Addr: 4209 GALL BLVD Address: 4034 GALL BLVD
ZEPHYRHILLS, FL 33542 ZEPHYRHILLS
Phone: (813)377-7395 Lic: Phone: 813-973-5250
Work Desc: NEW CONSTRUCT 4 UNIT TOWNHOME- 7007 SQ FT (#1 UNIT
� • � . 1
MECHANICAL FEE 32.49 SEWER CONNECTION RESIDEN" 2,010.00 WATER CONNECTION RESIDENI 641.00
WATER METER RES 3/4" 348.09 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES TOWNHOMES 769.56 SCHOOL IMPACT FEE/UNITS 0.00
SCHOOL IMPACT FEE-sfr/1% 0.00 TRAFFIC IMPACT FEE 99% 3,445.20 TRAFFIC IMPACT FEE 1% 34.80
FIRE PLAN REVIEW FEES 105.09
H �
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: Reinspection fees will comply with Florida Statute 553.80(2)(c)when extra inspection
trips are necessary due to any one of the following reasons: a) wrong address b)condemned work resulting
from faulty construction c) repairs or corrections not made when inspections called d)work not ready for
inspection when called e) permit not posted on job site t) plans not at job site g) work not accessible.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain fnancing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications and Must Acxompany Application. All work shall be pertormed in acxordance
with Ci Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
(�� """—�'�-
C NT CT SIGNATURE PERMIT OFFI
PER IT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
� C� l� �-�C Y C7 Y
id '� 7d
� � � � � � �
� x '� � r � �d
� � ~ bd � � �
C�7 -p � d fD
� �
bd � � � 00 �
� � � � �
r .. N �v
w
d z � � � � n
Z � � '� � ~
O o o %U tr-� i� Ui `�
�, � W � " � w O
� ° `� Cn ,�)
n o o r �
� � � r C� po N
� CD °o � � � CzJ
p N � x �
o � � x
� °
o � �
� � x
�='� O � �
� � � �
`'d v
�, � � r
z � � � �d
d � O ,�
r c � d
d � � �
� O N
" O
� � �
� �
v �
�
�. r+
� �
►y
0
C
cD
�
O
�
�
�
0
�
�
�
4408 COURT ST-BAILEY CONTRACTING LLC 4UNIT TOWNHOME
units-2-4
SQ. FEET PRICE
MAIN OR LIVING:
OTHER AREA UNDER ROOF: -
OTHER: - $ -
VALUATION
FEE SHEET
ADDRESS
DRIVEWAY
BUILDING: $ 330.69
ELECTRICAL: $ 69.64
PLUMBING: $ 46.43
MECHANICAL: $ 32.50
SUB-TOTAL $ 479.26
TOTAL S 479.26
SEWER: $ 2,010.00
WATER: $ 641.00
IRRIGATION: $ -
TOTAL: S 2,651.00
WATER METER: $ 348.09
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: $ 105.11
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: E 105.11
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 4,136.81
PARK IMPACT FEES E 769.56
SIF'S: $ 1,757.40
100.0% $ 1.740.00
1.0% $ 17.40
TOTAL: $ 1,757.40
T I F'S: S 3,480.00
99% $ 3,445.20
1°/a $ 34.80
TOTAL: $ 10,143.77
FORM 405-1 D
F�ORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Prr�fessiona/Regu/ation-Residentia/Pertormance Method
Project Name: Walnut Grovs TH 1202 N BuilderName: t�j.i,�F�{ �C7���-t-4¢►'T 4 L��-
SUeet: 4408 Coun Street Pem�itOflfce: Zephyrhlll� C��• �
City,Sfafe,Zip: Zephy�h!lfs,FL,33542- PermitNumber. (� �3�� �
Owner. Jurisdicfion: 611 B00
DesignLocation: FL,Tampa •
1. New conshuCtion orexistlnq New(From Plans) 9. Wall Typas(880.J sqft) lnsulation Aroa
2.Single/amilyo�fiultip/e hmily Multi-lamity a.ConCrete Block-In!Jnsul,Exterior R=4.0 378.72 R'
b.Frame-Wood,AdJacent Ra 11.0 185.36 R'
3. Numberofunits,ifmultip/efamity J aConcreteB/ock-lntMsul,Ad%acent R-�,p 96.00R'
4. Numbsrof8edrr�oms y d.N/A � k,
5. !s fh/s a worsf casel No 10.Cei/inp Types (1202.0 sqft.) lnsulation Area,
a.UndsrAldc(Vanfed) Ri30.0 1202.00lN
6. CondlNonad Bowarea abov�qrade(R') 7202 b.N/A Ra �
Condrt/oned flooraree belowgrade(ft=) 0 °•�A R= it'.
11.Ducts R �
7. Windows(72.2 sqRJ Descriptlon Area a.Sup:At�c,Reh HVAC 1,AN:HVAC� 6 199
B. U-Fac:or. Obl,U=0.50 72.23 R' - •
SHCaC: SHGC=0.50
b. U-Factor. N/p � 12.Cooling systems k8twhr EfFiciency
SHGC: a.Cenbal Unit 18.6 SEER:14.00
c. U-Pacfor. N/q � �
SHGC: 13.Hseting systsms k8lufir Efl'rciancy
d. U-Factor, lJ/A It= a.Elecbfc Neaf Pump' 17.6 HSPF:8.20
SHGC:
Area We/ghted Averape Ovefiany Depth: 4.639 1L
Area Weiqhted Averape ShiGC: p,50p 14.Hotwatersysfems
8. FloorTypes (1202.0 sqR.) lnsulaBon Aroa a.Bectric Cap:40gaf/ons
a.Slab-On-Grade E EF:0.920
dyelnsulation R=0.0 1202.00ft= b. Carservationfeatwes
b.N/A R= �' None
a N/A R° � 15.Credlts
Pstat
Glass/F1oorArea: 0.060 Tota/Proposeaf Mod�ed Loads: 22.77 PASS
Tota!Standard Reference Loads: 32.00
!heraby certify fhat the plans and s �ifications covered by Review of the plans and 04�STqT�
this calculation a�in com nce the Florida Energ�y speciNcations cover�d tiy this - p
�e• � calculafion indicates compliance ' y� r� �
' with the Flodda Ene►g�y Coiie. `p
PREPA D Y��.. � eeforts construcfion is complefed � _ . ' �..°
�� C II
DATE: ��`. � " this building will be inspected for ` � y
' - - - compliance with Seciion 553.908 t ,
1 hereby cer::fy that this`buiJding,'as designed,is in compliance Florida Statutes. .
with fhe rlorida Ene�y Code. �CpD�.�,�
OWNER/AGENT.� BUlLDlNG OFFlCIAL:
DATE: DATE:
- Compliance requires cerdflcation by the�ir handler unit manufacturer that the air handler•enciosure qualifes as -
certlfisd hctory-sealed in accordance with 403.2.2.�.1.
- Compiiance requires completion of a Florida Air Barrier and Insulation Inspection Checklist �
11/4/2013 11:30 AM EneryyGauge�USA-FlaRes2010 Secdon 405.4.1 Compllant Software Paye 1 015
I
, ._... . `
PROJECT
T'rt/e: Walnut Grove TH 1202 N Bedrooms: 2 Address Type: Street Address
BuiJding Type: User Cond'rtioned Area: i202 Lot#
Owner: Tota/Stories: 1 B/ock/SubDivision:
#ol Units: i Worst Case: No P/atBook:
Builder Name: Rotate Angle: 0 Sheet: 4408 Court Street
Permit OH'�ce: Zephyrhills Cross Ventilation: County: Pasco
Ju�isdiction: 611600 Whole House Fan: Cdy,State,Zip: ZephyrhiHs,
Family Type: Multi-family FL, 33542-
New/Existing: New(From P/ans)
Comment:
CLIMATE
/ IECC Design Temp lnt Design Temp Heating Design Daily Temp
\� Design Locatbn TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL, Tampa FL_TAMPA /NTERNATlO 2 39 91 72 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Bbck 1 1202 9616
SPACES
Number Name Area Volume K'rtchen Occupants Bedrooms Infi!ID Finished Cooled Heated
1 HVAC 1 1202 9616 Yes 3 2 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 S/ab-On-Grade Edge Insu/atb HVAC 1 841i 0 1202 ft2 ____ 0.4 0.4 0.2
ROOF
� Roof Gable Roof So/ar SA EmiK Emitt Deck Pdch
� Type Materials Area Area Cobr Absor. Tested Tested InsuL (deg)
1 Hip Composition shingles 1267 H2 0 it2 Dark 0.96 No 0.9 No 0 18.4
ATTIC
V # Type Ventilation Vent Ratb(1 in) Area RBS IRCC
1 Full attic Vented 300 12021t2 N N
CEILING
# Ceiling Type Space R-Va/ue Area Framing Frac Truss Type
1 Under Attic(VentedJ HVAC 1 30 1202/tz 0.11 Wood
11/4/2013 11:30 AM EnergyGauge�USA-F/aRes2010 Sectan 405.4.1 Compbant Software Page 2 of 5
WALLS
Adjacent S�Ce Cavdy Width Heghf Sheathing Framing So/ar Below
_ 1 W Garage Frame-Wood HVAC 1 11 3.83 0 8 0 30.6 ft2 0 0.23 0.01 0
_ 2 N Garage Frame-Wood HVAC 1 11 3.17 0 8 0 25.4 R2 0 0.23 0.01 0
_ 3 W Garage Frame-Wood HVAC 1 11 7.5 0 8 0 60.0/t2 0 0.23 0.01 0
4 N Exterior Concrete Bbck-Int/nsul HVAC 1 4 4 D 8 0 32.01tz 0 0 0.35 0
5 N Exterior Concrete Block-Int Insul HVAC 1 4 9.67 0 8 0 77.4/t2 0 0 0.35 0
_ 6 E Garage Concrete Bbck-Int lnsui HVAC 1 4 12 0 8 0 96.0 ft2 0 0 0.01 0
_ 7 N Garage Frame-Wood HVAC 1 11 8.67 0 8 0 69.4 R? 0 0.23 0.01 0
8 S Exterioi Concrete 81ock-Inf Insul HVAC 1 4 12.67 0 8 0 101.4 ft2 0 0 0.35 0
9 S Exferror Concrete 8/ock-Int Insul HVAC 1 4 12.83 0 8 0 102.6 ft� 0 0 0.35 D
f0 E Exterar Concrete B/ock-Int lnsu/ HVAC 1 4 8.17 0 8 0 65.4 It2 0 0 0.35 0
DOORS
�Y Ornt Door Type Space Storms U-Va/ue Ft w�h!n FHe�h In Area
1 W lnsu/ated HVAC 1 None 0.35 3 0 6.67 0 20.0J000
2 N lnsulated HVAC 1 None 0.35 3 0 6.67 0 20.0f000
WINDOWS
Orientation shown is the entered,Proposed orientation.
J Wall Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N 5 TIM Low-E Doub/e Yes 0.5 0.5 23.2 itz 1!t 0 rn 1 1t 0 in Drapes/blinds Exter'ar 5
2 S 8 T!M Low-E Double Yes 0.5 0.5 12.8 ft2 9 ft 0 in 0 R 0 in Drapes/blinds Exterior 5
3 S 8 TIM Low-E Double Yes 0.5 0.5 20.0 ftz 9 R 0 in 01t 0 in Drapes/blinds None
4 S 9 TIM Low-E Double Yes 0.5 0.5 16.2 ft2 i It 0 in 1 1t D in Drapes/blinds Exterar 5
GARAGE
�Y Fbor Area Ceiang Area Exposed WaU Perimeter Avg. WaN Height Exposed Wall Insulafan
1 226 ft2 226 ft2 4B ft 8 ft 0
INFILTRATION
A� Scope Method SLA CFM 50 ELA EqLA ACH ACH 50
1 Wholehouse Best Guess 0.000300 945.859 51.9264 97.6552 0.22500 5.90178
HEATING SYSTEM
�Y System Type Subrype Eff'�ciency Capacity Block Ducts
(�nva/iElectric Heat Pump None HSPF:8.2 17.6 k8tu/hr 1 sys�fl
11/4/2013 11:30 AM EnergyGauge�USA-F/aRes2010 Sectbn 405.4.1 Compliant Software Page 3 of 5
COOLING SYSTEM
# System Type Subtype EH'Kiency Capacity Air Fbw SHR Block Ducts
(lnvaliCentra/Un'rf None SEER:14 18.6 k8fu/hr 558 cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.92 40 ga/ 50 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
CeR # Company Name System Model# Collector Model# A�ea Vo/ume FEF
None None n2
DUCTS
� ----Supp/y---- ----Return---- Air CFM25 HVAC#
# Locatan R-Va/ue Area Locatan Area Leakage Type Handler CIF�p5 OUT QN RLF Heat Cool
�1nvaN Attic 6 199 ftz HVAC 1 16/tf De/au/t Leakage HVAC 1 (invatid)cf(Delau/t)c 1 1
TEMPERATURES
Programable Thermostat: Y Ceiling Fans:
Coobng Jan Feb Mar Apr May ( Jun Jul Au X Se Oct )Nov Dec
Heating Jan Feb Mar A�r 4�Ma y (�Jun (�Jul �(�Au� (�Se� �(�Oct f Xj Nov ��Dec
Venting ( Jan ( Feb Mar A r j Ma j Jun j Jul ( Au j Se j Oct (XJ Nov
Thermostat Schedule: HERS 2006 Reference Hours
SchedWe Type 1 2 3 4 5 6 7 8 9 f 0 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 7B 78 78 7B 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 6B 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
11/4/20Y3 11:30 AM EnergyGauge�USA-F/aRes2010 Sectan 405.4.1 Compliant Soltware Page 4 of 5
FORM 405-10
Florida Code Compiiance Checklist -
Florida Deparfinenf of Business and Professiona!Regulations
Residenfia/ Whole Buiiding Performance Mefhod
ADDRESS: 4408 Court Street PERM/T#:
Zephyrhills,FL, 33542-
MANDATORY REQUIREMENTS SUMMAI�Y-See indtvidual code sections for full details.
COMP�NENT SECTION SUMMARYOF REQUIREMENT(S) CHECK
Airleakage 402.9 To be cau/ked,gaskefed, weatherstripped orofhen�vise sea/ed.
Recessedlighting IC-rated as meeting ASTM E 283. Windows and
doors=0.30 cfm/sq.ft. Testing or visual inspection required. ✓
Fir�eplaces:gasketed doors&outdoor combustion air. Must complete
envelope leakage report or visually verify Table 402.4.2.
rneR►►osrar a -t03.1 Atleast one thermostat shall be provided foreach separate heating
conProls and coo/ing system. Whens for+ced-air fumace is primary system,
programmable thermosfat is required.HQat.pumps with supplementai �
e/ectric heaf must prevent supp/ementa!fieat when compressor can
meet the load.
oucts 403.2.2 A!!ducts, air handlers, filter boxes and building cavifies which form the �
primary aircontainment passageways forair�Iisfribution systems shall
be consider+�d ducts or plenum chambers,shall be constructed and �
sealed in accordance wifh Section 503.2.7.2 of this code.
403.3.3 Building framing cavities sha11 not be used as suppJy ducts.
Water heaters d03.4 Heaf trap required for verflcal pipe risers. Comp/y with efficiencies in
Table 403.4.3.2. Provide switch or Gearly marked circuit breaker �-.
(e/ectric)or shutoff(gas). CirGUlating system pipes insulated to=
R-2+accessrble manua!OFF switch. � ,
Mechan�cal ao3.5 Homes designed to operate at positive pressure or with mechanica!
ventilation ventilation systems shall not exceed the minimum ASHRAE 62/evel. �
. No make-up air from attics,craw/spaces,garages oroutdoors adjacent ✓
, to pools or spas. �J�,.�� -
SwimmingPools 403.9 •poo/pumps and pool pump motors wlth a tota!hoisepow�r(HPJ of= '1
&S�as � . ., HP�shall have the capabilify of operatfng at two or more speeds. Spas
,. ' � and heated poo/s must have vapor-retarolant covers or a liqpid cover or,
, - • � _ oti►ermeans proven to reduce heatloss except if709�C of heat from
� �
site-recovered energy, OffRimer switch required. Gas heaters minimum �{��
thermal e�ciency=78%(82%after 4/16/13). Heat pump pool heaters / "
minlmum COP=4.0.
Cooiingfiee�ng 403.6 Slzing ca/cu/ation pertormed&atfached. Minimum efficiencJes per
•Tab/es 503.2.3.Equipment efficiency ve�cation required. Specia!
equlpment o0�as/on cooling or heating capaciry requfres separate system or ,�
variab/e capacity system. Elecfric heat>lOkW must be divided into two
or more stagss. •
Ceilingsllcneewalls 405.2.1 R-19 space permitting.
1 l/4/2013!1:90 AM EneryyGauqe�U5A-F1aRes2010 Sectiort 405.4.1 Compliant Soltware Pape 5 of 5
� _ . ,.. . _ __.,.___—... ._ . .. . -
ENERGY PERFORMANCE LEVEL {EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE lNDEX* - 71
The lower the EnergyPerformance Index, the more efficient the home.
4408 Court Streef, Zephyrhills, FL, 33542-
1. New consiruction or existing New(From P/ans) 9. Wall Types /nsulatbn Area
2. Sing/e family or multip/e famity Mu/t'rfamity a.Concrete Block-Int Insul,Exterior R=4.0 378.72 Rz
b.Frame-Wood,Adjacent R=11.0 185.36 R2
3. Number ol units,if mu/tipl�tamily i c.Concrete Block-Int Insul,Adjacent R=4.0 96.00 R2
4. Number of Bedrooms p � d.N/A R= R2
10.Ceiling Types Insulation Area
5. Is this a worst case? No a.UnderAttic(Vente�) R=30.0 i202.00 ft2
6. Cond'rtioned f/oor area(RZ) 1202 b.N/A R= ft2
7. Windows" Description Area
c.N/A R= ft2
a. U-Factor: Dbl,U=0.50 7p,23 hz 11•Ducts R 112
a.Sup:Attic,Ret:HVAC 1,AH:HVAC 1 6 199
SHGC: SHGC=0.50
b. U-Factor: N/A R?
SHGC: 12.Cooling systems kBtu/hr Ef/'�ciency
c. U-Factor: N/A RZ a.Central Unft 18.6 SEER:14.00
SHGC:
d. U-Factor: N/A nZ 13.Heating systems kBtuihr Efficiency
SHGC: a.E/ectric Heat Pump 17.6 HSPF.•8.20
Area NJe�hted Average Overhang Depth: 4.639 ft.
Area Weighted Ave�age SHGC: 0.500
8. F/oor Types Insulation Area 14•Hot water systems
a.S/ab-On-Grade Edge lnsu/ation R=0.0 1202.00 ftz a.Electric Cap:40 galbns
b.N/A R= n2 EF:0.92
c.N/A R= ftz b. Conservatbn features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Consfruction through fhe above energy saving features which will be installed(or exceeded) .y 04���0
in fhis home before fin�l inspection. Otherwise, a new EPL Display Card will be comp/eted ykf' '� '°,,,s,
based on installed Code compliant features. '`� �
Builder Signature: Date: � � � � �
* �
Address of New Home: City/FL Zip: 4�,
QaD�.1$.�
"Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Confact the EnergyGauge Hotline at(321)
638-i492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, confacf the Florida Building Commission's
support stan.
"'Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge�USA-FlaRes20f0 Sectan 405.4.1 Comptiant Software
TABLE 402.4.2
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Walnut Grove TH 1202 N Bui�aler Name:
Streat: 4408 Court Street Permit Oflice: Zephyrhills
Ciry,State,Zip: Zephyrhills,FL,33542- Permd Number:
Owner: Jurisdiction: 611600
Design Location: FL, Tampa
COMPONENT CRITERIA CHECK
Air barrier and therma/barrier Exterior thermal envelope insulation for framed walls is installed in
substantial contact and continuous alignment with building envelope
air barrier.
Breaks or joints in the air barrier are filled or repaired.
Air-permeable insulation is not used as a sealing material.
Air- ermeable insulation is inside of an air barrier.
Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with
insulation and any gaps are sealed.
Attic access(except unvented attic), knee wall door, or drop down
stair is sealed.
WaJs Corners and headers are insulated.
Junction of foundation and sill plate is sealed.
Windows and doors Space between window/door jambs and framing is sealed.
Rim joisis Rim jorsts are insulated and include an air barrier.
Floors (including Insulation is installed to maintain permanent contact with underside
above-garage and of subfloor decking.
cantilevered floors)
Crawl space walls Insulation is permanently attached to walls.
Exposed earth in unvented crawl spaces is covered with Class I
Shafts,penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening
_ to exterior or unconditioned space are sea/ed.
Narrow cavities Batts in narrow cavrties are cut to fit, or narrow cavities are filled by
sprayed/blown insulation.
Garage separafion Air sealing is provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures are air tight, !C rated, and sealed to drywall.
Exception--fixtures in conditioned space.
Plumbing and wiring Insulation is p/aced between outside and pipes. Batt insulation is cut
to fit around wiring and plumbing, or sprayed/blown insulation
Shower/tub on exterior wall Showers and tubs on exterior walls have insulafion and an air
barrier se aratin them from the exterior wall.
Electrica!/phone box on Air barrier extends behind boxes or air sealed-type boxes are
installed.
Common wall Air barrier is installed in common wa11 between dwelling units.
HVAC register boots HVAC register boots that penetrate building envelope are sealed to
subfloor or d wall.
Fire lace Fire /ace walls include an air barrier.
EnergyGauge�USA-F/aRes20f0 Section 405.4.1 Compliant Software
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
HVAC Designs � Wa/nut Grove TH 1202 N
Ta a,FL 33615 Pa e 1
Project Report
General Pro'ect information
Project Title: Walnut Grove TH 1202 N
Projeci Date: Saturday,November 02,2013
Company Name: HVAC Designs Inc
Compz��y Representative: Neil Fimbel
Company Address: 7701 W Hanna Ave
Company City: Tampa FL 33615
Company Phone: (813)885�2258
Company E-Mail Address: neil@hvacdesigns.com
Company Website: http:llwww.hvacdecigns.coml
Desi n Data
Reference City: Zephyrhill ,Florida
Building Orientation: Front Door faces North
Daily Temperature Range: Medium
Latitude: 28 Degrees �
ElevatEon: 19 ft.
Altitude Factor: 0.999
Outdoor Outdoor Outdoor Indoor Indoor Grains
Drv Bulb Wet Bulb Rel.Hum Rel.Hum Drv Bulb Difference
Winter: 40 37.52 nla nla 72 n/a
Summer: 93 77 49°/a 55% 75 43
Check Figures
Total Building Supply CFM: 600 CFM Per Square ft.: 0.499
S�uare ft.of Room Area: 1,202 Square ft.Per Ton: 1,049
Volume(ft�of Cond.Space: 9,620
Building Loads
Total Heating Required Including Ventilation Air: 13,872 Btuh 13.872 MBH
Total Sensible Gain: 10,316 Btuh 76 °�
Total Latent Gain: 3,255 Btuh 24 %
Total Cooling Required Including Ventilation Air: 13,572 Btuh 1.15 Tons(Based On 75%Sensible Capacity)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculatlons are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
All omFuted results are estimates ac building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions.
Monday,November 04,2013,11:48 AM
Rhvac-Residential&Llght Commercial HVAC Loads Elite Software Development,Inc.
HVAC Designs � Walnut Grove TH 1202 N
Tam a,FL 33615 Pa e 2
Manual D Ductsize Data-Duct S stem 1 •Su 1
-Duct Name,etc.
Type Roughness Diameter Velceity SPL.Duct
Upstream Temperature Width LossH00 SPL.Fit
Shape Length Height FitEq.Len SPL.Tot
Sizin CFM Area SP.Avail SPL.Cumul
-Duct Name:SMT•100,Feeds Into:Foyer,Fitting:l•A,Effective Length:23.9
Trunk 0.003 12.4 665 0.005
Up:Fan 57 10 0.085 0.015
Rect 6.0 13 17.9 0.180
Schedule 600 23 0.109 0.230
-Duct Name:SR•100,Supplies:M Bath,Fittings:ll-B,11-B,4AA,11-B,Effective Length:17.0
Runout 0.01 4 206 0.005
Up:ST-110 57 3.1 0.050 0.003
Rnd 10.6 4.4 6.3 0.008
Schedule 18 11.1 0.071 0.268
_..._. __.. _ __..... . . . _ __ _ ___. __.. _.....
-Duct Name:SR•110,Supplies:M Bed,Fittings:ll•B,11•B,4AA,Effective Length:21.2
Runout 0.01 6 504 0.021
Up:ST•110 57 4.7 0.162 0.014
Rnd 12.7 6.6 8.5 0.034
Schedule 99 20 0.045 0.294
__...._.. ___._. _...._. _ _........ _. . . _...._ . _ ___ _._..
-Duct Nama:SR-120,Supplies:M Wic,Fittings:l1•6,11-B,4AA,11•B,Effective Length:13.1
Runo�±t 0.01 4 34 0.000
Up:ST-110 57 3.1 0.002 0.000
Rnd 8.2 4.4 4.8 0.000
Schedule 3 8.6 0.080 0.260
-Duct Name:SR•130,Suppiies:Great 1 Dining,Fittings:ll-B,11-B,4AA,Effective Length:18.3
Runout 0.01 6 530 0.018
Up:ST•110 57 4.7 0.179 0.015
Rnd 10.1 6.6 8.2 0.033
Schedule 104 15.9 0.047 0.292
-Duct Name:SR-140,Supplies:Bed 2,Fittings:11-B,11•B,4AA,Effective Length:15.0
Runout 0.01 5 594 0.025
Up:ST•120 57 3.9 0.289 0.018
Rnd 8.7 5.5 6.3 0.043
Schedule 81 11.3 0.004 0.335
-�uct Name:SR•150,Supplies:Foyer,Fittings:ll-6,11-B,4AA,11-B,Effective Length:10.5
Runout 0.01 4 596 0.016
Up:ST•120 57 3.1 0.398 0.026
Rnd 4.1 4.4 6.4 0.042
Schedule 52 4.2 0.006 0.334
_ _
-�uct Name:SR-160,Supplies:Bath 2,Fittings:l1-8,11-B,4AA,11•B,Effective Length:12.2
Runout 0.01 4 229 0.003
Up:ST-120 57 3.1 0.061 D.004
Rnd 5.2 4.4 6.9 0.007
Sched�le 20 5.5 0.040 0.300
-�uct Name:SR-170,Supplies:Kitchen,Fittings:l1-B,4AA,11•B,Effective Length:20.2
Runout 0.01 6 606 0.023
Up:ST-120 57 4.7 0.233 0.025
Rnd 9.7 6.6 1a.5 0.047
Schedule 119 15.3 0.000 0.339
Monday,November 04,2013,11:48 AM
Rhvac-Res(dentlal&Light Commercial HVAC Loads � Elite Software Deveiopment,Inc.
HVAC Designs Walnut Grove TH 1202 N
Ta a,FL 33615 Pa e 3
Manual D Ductsize Data-Duct S stem 1 -Su I cont'd
–Duct Name,etc.
TYPB Roughness Diameter Velocity SPL.Duct
Upstream Temperature Width Loscl100 SPL.Fit
Shape Length Height FitEq.Len SPL.Tot
Sizin CFM Area SP.Avail SPL.Cumul
–Duct Name:SR•180,Supplies:Great 1 Dining,Fittings:ll•B,11-B,4AA,Effective Length:16.5
Runout 0.01 6 530 0.014
Up:ST•120 57 4.7 0.179 0.015
Rnd 7.9 6.6 8.6 0.030
Schedule 104 12.4 0.018 p,3�
—�uct Name:ST•110,Feeds Into:Greatl Dining,Fittings:11•B,11•B,11•A,Effective Length:55.0
Trunk 0.01 10 411 0.012
Up:SMT•100 57 7.8 0.054 0.018
Rnd 22.3 10.9 32.7 0.030
Schedula 224 58.5 0.080 0.260
_.. _.._ __ _... __._.... _ ....... __ .......__ _._ __....... _
—=uct Name:ST-120,Feeds Into:Kitchen,Fittings:ll-B,11-B,11-A,Effective Length:41.5
Trunk 0.01 10 689 0.008
Up:SMT-100 57 7.8 0.150 0.054
Rnd 5.1 10.9 36.3 0.062
Schedule 376 13.4 0.047 0.292
__ _....... _ __...... _...... _ ___. _ _ ......... _..._ __..
Report Units:Pressure:in.wg,Duct lengths:feet,Duct sizes:inch,Airflow:CFM,Velocity:RJmin,Temperature:F
Notes: Static pressure available values for return ducts are at the entrance of the duct. For supply,they are at the exit The cumulative static
pressure loss value for a return trunk is with respect to the entry point of the return runout upstream with the hlghest static pressure available. Total
and cumulative static pressure loss values for the supply main trunk include any device pressure losses entered,and the cumulative may also
lnciude the total static pressure loss of the return side.
Summa
Number of active trunks: 3
Number of active runouts: g
Total runout ouUet airflow: 600
Mair trunk airflow: 600
Largest trunk diameter: 12.4 SMT•100
Largest runout diameter: 6 SR-110
Smal1•st trunk diameter: 10 ST•110
Smallest runout diameter: 4 SR•100
Supply fan oxternal stadc pressure: 0.339
Supply fan device pressure losoes: 0.160
Supply fan static prescure available: 0.179
Runout maximum cumulative atatic pressure loss: 0.339 SR•170
Return loss added to supply: 0.050
Total effective length of return(ft.�: 60.2 RR•100
Tota1 effective length of supply(ff.j: 85.6 SR-170
Overall total effective len9���)� 145.8 RR-100 to SR•170
Design overall iriction rate per 100 ft.: 0.123 (Avatlable SP x 1001 TEL)
System duct surface area(Scenario 1): 176.4 Hot Vented Attic (Linked to duct load)
System duct surface area(Scenario 4): 23 Exposed in Space (Linked to duct load)
Total syttem duct surface area: 199.4
Monday,November 04,2013,11:48 AM
Rhvac-Residential&Llght Commercial HVAC Loads Elite Software Development,Inc.
HVAC Designs � Wa/nut Grove TH 1202 N
Tam a,FL 33615 Pa e 4
Manual D Ductsize Data-Duct S stem 1 -Return
—�uct Name,etc.
Type Roughness Diameter Velceity SPL.Duct
Upstream Temperature Width Loss1100 SPL.Fit
Shape Length Height FitEq.Len SPL.Tot
Sizin CFM Area SP.Avail SPL.Cumul
—Duct Name:RMT•100,Feeds From:Foyer,Fitting:5-B,Effective Length:38.0
Trunk 0.003 12.4 665 0.002
Up:Fan 75 10 0.082 0.029
Rect 3.0 13 35.0 0.031
Schedule 600 11.5 -0.018 0.050
—Duct Name:RR•100,Returns From:Foyer,Fitting:2-D,Effective Length:22.2
Runout 0.003 12.4 665 0.001
Up:RMT•100 75 10 0,082 0.017
Rect 1.0 13 21.2 0.018
Schedule 600 3.8 0.000 0.018
_.... _.... ___ __. _ _ _.__ _.._...... ___._. _. _ __ _...... __... _....._
Report Units:Pressure:in.wg,Duct lengths:feet,Duct sizes:inch,Airflow:CFM,Velocity:ft.lmin,Temperature:F
Notes: Static pressure available values for return ducts are at the entrance of the duct. For supply,they are at the exit The cumulative static
pressure loss value for a return trunk is with respect to the entry point of the return runout upstream with the highest static pressure available. Total
and cumulative static pressure loss values for the supply main trunk include any device pressure losses entered,and the cumulative may also
include the total s�tic pressure loss of the return side.
Summa
Number of active trunks: 1
Number of active runouts: 1
Total runout outlet sirflow: 600
Main trunk airflow: 600
Largest trurk diameter: 124 RMT-100
Largest runout diameter: 12.4 RR•100
Smallest trunk diameter: 12.4 RMT-100
Smallest runout dlameter: 12.4 RR-100
Runout maximum cumulative static pressure loss: 0.018 RR•100
Return loss added to supply: 0.050
Total affective length of return(ft.): 60.2 RR-100
System duct surface area(Scenario 4): 15.3 Exposed in Space (Linked to duct load)
Total system duct surface area: 15.3
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
All omputed results are estimates as building use and weather may vary.
Be sure to select a unit that meeta both sensible and latent loads according to the manufacturer's performance data at your design conditions.
Monday,November 04,2013,11:48 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
HVAC Designs � Walnut Grove TH 1202 N
Tam a,FL 33615 Pa e 5
Manual D Ductsize-Pressure Chan es Gra h-S stem 1
Pressure Changes Through Route with Highest Static Pressure Loss
o.�s
�._.`.....,,
o.�a ;�- ��__�
r , _ �
0.12 i' ;� ' �_._� ��
,; ,\
0.f0 � ! � �
: � ����
0.08 � � �� �
� /: /; ��
I
C �.�6 � ��� \ \���
�
l /� �� \
\
N 0.04 � �� �\
� i % �
_ ' � ��
a 0.02 �'�- j� l
` r, /,
0.00 _ -��
_ _ ,; ��
/ ,
-0.02 "'�'-� , ,;
-0 04 �,
- ., �
-0.06
_._.......�._......... Static P�essure Available
Total Piessure Available
_..._ .... ........._. _........ .. _... _.__. _ ._...... _.. __ . .. .._.... .. _ ........ __..... _..... __.
Notes: Return side point values are at entrance of duct,while supply side points are at exit When a return system is present,an additional return
side point named[Fan Ent�ance]is drawn in the graph to show the atatic pressure available at the entrance of the fan. When a supply system is
present,and an additional supply side point named[Fan Exit]is drawn to show the static pressure available at the exit of the fan. Any device
pressure losses entered for the supply main trunk are accounted for between the fan entry and exit points.
Point Name Static Pressure Available Total Pressure Available
A RR-100 0.000 0.027
B RMT-100 -0.016 0.009
C [Fan Entrance] -0.050 -0.022
D (Fan Exit] 0.130 0.158
E . SMT-100 0.109 0.138
F ST-120 0.047 0.078
G SR•170 0.000 0.023
Monday,November 04,2073,11:48 AM
Rhvac-Residential&Light Commercial HVAC Loads � Elite Software Development,Inc.
HVAC Designs Wainut Grove TH 1202 N
Tam ,FL 33615 Pa e 6
Total Buildin Summa Loads
Component Area Sen Lat Sen Total
Description Quan Loss Gain Gain Gain
OP LOW E MIN:Glazing•NFRC CODE MIN Operable 2 52.2 835 0 654 654
Pane Low E,ground reflectance=0.23,outdoor
insect screen with 50°/.coverage,light color blinds
at 45°with 1C�7.coverage,u-value 0.5,SHGC 0.5
FD LOW E MIN:Glazing-NFRC CODE MIN Glass Door 2 20 320 0 278 278
Pane Low E,ground reflectance=0.23,light color
blinds at 45°with 100'/e coverage,u-value 0.5,
SHGC 0.5
11N:Door-Metal•Polystyrene Core 40 434 0 343 343
12B-0sw:Part-Frame,R•11 insulation in 2 x 4 stud 165.4 481 0 321 321
cavity,no board insulation,siding finish,wood
studs
13A-4ocs:Wall Block,board insulaGon only,R-4 board 286.5 1,311 0 749 T49
insulation,open core,siding Nnish
13A-4ocs:Part-Block,board lnsulation only,R-4 board 96 412 0 275 275
insulation,open core,sidfng finish
168•30-�d:RooflCeiling-Under Attic with Insulation on 1202.6 1,231 0 2,041 2,041
Attic Floor(also use for Knee Wall and Partition
Ceilings),vented attic,no radiant barrier,R-30
insulation,dark asphalt
22A-pm:Floor-Slab on grade,No edge insulation,no 84 3,172 0 0 0
insulation below floor,any floor cover,passive,
_____heavy dry or light wet soil_
-- - --- - _ - -__ _ _-- __ - ----- ---_ ----- _ _ - -' -- --- ---- ---
Subtotals for structure: 8,196 0 4 661 4 661
Pe0P1e� 3 690 900 1,590
Equipment: 640 2,040 2,680
Lighting: 0 0 0
Ductwork: 1,728 235 1,573 1,809
Infiltration:Winter CFM:112,Summer CFM:58 3,948 1,690 1,142 2,632
Ventiladon:Winter CFM O,Summer CFM 0 0 0... 0 0
_ __ _.... __ _..__
Total Building Load Tot�ls: 13,872 3,255 10,316 13,572
Check Figures
Total Building Supply CFM: 600 CFM Per Square ft.: 0.499
Square ft.of Room Area: 1,202 Square it.Per Ton: �,pqg
Volume(ft')of Cond.Space: 9,620
Buildfn Loads
Total Heati�g Required Including Ventllatlon AIr: 13,872 Btuh 13.872 MBH
Totai Sensible Gsfn: 10,316 Btuh 76 °/.
Total Latent Gain: 3,255 Btuh 24 °/.
Total Cooling Required Including Ventiladon Air: 13,572 Btuh 1.15 Tons(Based On 75°k Sensible Capacity)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions.
Monday,November 04,2013,11:48 AM
Rhvac-Residential&Ltght Commercial HVAC Loads � Elite Software Deve�opment,Inc.
HVAC Designs Walnut Grove TH 1202 N
Tam a,FL 33615 Pa e 7
S stem 1 Room Load Summa
Htg Min Run Run Cig Clg Min Act
Room Area Sens Htg Duct Duct Sens Lat Cig Sys
No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM
—Zone 1—
2 Foyer 57 2,145 49 4 - 889 143 45 52
3 Bed 2 145 3,217 73 5 - 1,401 345 7� g1
4 Bath 2 54 682 16 4 • 339 60 17 20
5 KEtchen 201 235 5 6 • 2,054 500 104 119
6 GreatlDi�ing 415 3,211 73 6,6 • 3,573 1,142 181 208
7 M Wic 27 31 1 4 - 54 0 3 3
8 M Bath 106 125 3 4 - 308 80 16 18
9 M Bed _ 197 4,227._ __..96 6 - __ 1,699___ 750 86 99
_ . _.. _ _ _....._
Duct Latent _ Z35
_. _ _.._. __. _.__.... _. _ __.
System 1 total 1,202 ,_ 13,872 315 10,316 3,255 521 600
__ _..._ _ _ _...._ __ ____ _....
System 1 Main Trunk Size: 10x13 in.
Velocity: 665 ftJmin
Loss per 100 R: 0.085 in.wg
Ouct size results above are from Manual D Ductsize.
Runout duct velocities are not printed with duct size results from Manual D Ductsize since they can vary within the room. See the Manual D Ductsize
report for duct velocities and other data.
Coolin S stem Summa
Cooling SensiblelLatent Sensible Latent Total
Tons S lit Btuh Btuh Btuh
Recommended �,15 75•/.125°/. 10,316 3,439 13,755
ACtual: 1.55 75%125% 13,950 4�650 18�600
Equipment Data
Heatina Svstem Coolina S�ntem
Type: Air Source Heat Pump Air Source Heat Pump
Model: 4A6H3018C1 4A6H3018C1
Indoor Model: GAF2AOA18S11+TDR
Brand: HERITAGE 13 HERITAGE 13
Description: Air Source Heat Pump Air Source Heat Pump
Efficiency: 8.2 HSPF 14 SEER
Comment: p
Sound: 0 0
Capacity: 17,600 Btuh 18,600 Btuh
Sensible Capaclty: nla 13,950 Btuh
Latent Capacity: nla 4,650 Btuh
AHRI Reference No.: nla ,q,q41Y99
This cy�tem's equipment was selected in accordance with ACCA Manual S.
Manual S equlpment sizing data: SODB:93F,SOWB:77F,WODB:40F,SIDB:75F,SIRH:55%,WIDB:72F,Sen.gain:10,316 Btuh,Lat gain:3,255
Btuh,Sen,loss:13,872 Btuh,Entering clg.coil DB:75F,Entering clg.coil WB:63.9F,Entering htg.coil DB:72F,Clg.coil TD:18F,Htg.coil TD:40F,
Req.cig.airflow:521 CFM,Req.htg.airflow:315 CFM
Monday,November 04,2013,11:48 AM